首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.

Background  

Single path defibrillation shock methods have been improved through the use of the Charge Banking Model of defibrillation, which predicts the response of the heart to shocks as a simple resistor-capacitor (RC) circuit. While dual path defibrillation configurations have significantly reduced defibrillation thresholds, improvements to dual path defibrillation techniques have been limited to experimental observations without a practical model to aid in improving dual path defibrillation techniques.  相似文献   

2.
The degree to which weather influences the occurrence of serious cardiac arrhythmias is not fully understood. To investigate, we studied the timing of activation of implanted cardiac defibrillators (ICDs) in relation to daily outdoor temperatures using a fixed stratum case-crossover approach. All patients attending ICD clinics in London between 1995 and 2003 were recruited onto the study. Temperature exposure for each ICD patient was determined by linking each patient’s postcode of residence to their nearest temperature monitoring station in London and the South of England. There were 5,038 activations during the study period. Graphical inspection of ICD activation against temperature suggested increased risk at lower but not higher temperatures. For every 1 °C decrease in ambient temperature, risk of ventricular arrhythmias up to 7 days later increased by 1.2 % (95 % CI ?0.6 %, 2.9 %). In threshold models, risk of ventricular arrhythmias increased by 11.2 % (0.5 %, 23.1 %) for every 1° decrease in temperature below 2 °C. Patients over the age of 65 exhibited the highest risk. This large study suggests an inverse relationship between ambient outdoor temperature and risk of ventricular arrhythmias. The highest risk was found for patients over the age of 65. This provides evidence about a mechanism for some cases of low-temperature cardiac death, and suggests a possible strategy for reducing risk among selected cardiac patients by encouraging behaviour modification to minimise cold exposure.  相似文献   

3.
4.

Background

Implantable Cardioverter-defibrillators (ICD) reduce mortality in survivors of cardiac arrest (CA). We investigated the predictors of mortality after ICD implantation in survivors of CA.

Methods

Retrospective review of clinical records and social security death index of all patients who received an ICD in a preexisting database of survivors of CA at the University of Pittsburgh Medical Center was performed. Multivariate analyses using the Cox proportional hazard model were performed with backward elimination to identify independent predictors of the time to death, and Kaplan-Meier curves were plotted.

Results

Eighty patients (64 men) with a mean age of 64.4±12.5 years were followed for 4.7±2.3 years after ICD implantation. Survival rates were 93.8%, 65% and 50% at 1, 5, and 10 years, respectively. Independent predictors of time to death were determined to include age (hazard ratio (HR) = 1.91 per 10-year increase, p = 0.003), serum creatinine ≥ 1.3 mg/dL (HR = 2.56, p = 0.004), and QRS width >120 ms (HR = 5.14, p = 0.012).

Conclusions

In this sample of ICD recipients secondary to CA, older age, elevated serum creatinine, and wider QRS duration were independent predictors of mortality. The presence of more than one risk factor in the same patient was associated with higher mortality rates. Whether interventions such as biventricular pacing can offset this increase risk of death warrants further investigation.  相似文献   

5.
6.
Hypertrophic cardiomyopathy (HCM) is an important cardiovascular disease with sudden cardiac death as the most devastating presentation. Implantable cardioverter defibrillators (ICD) are the optimal therapy for prevention of sudden death from ventricular tachycardia or fibrillation of any cause. While there is no controversy with implanting ICDs in patients who have already survived a cardiac arrest, identifying high-risk patients for primary prevention in this disease remains a challenge. Implanting ICDs in patients with HCM is an important clinical consideration since many individuals could achieve normal or near-normal lifespans with this protection.  相似文献   

7.
A commercially available magnetic therapy system, designed for clinical application as well as for private use without medical supervision, was examined with respect to its potential for causing electromagnetic interference with implantable pacemakers (PMs) and automatic implantable cardioverter defibrillators (AICDs). A sample of 15 PMs and 5 AICDs were experimentally investigated. Each of the implants was realistically positioned in a homogeneous, electrically passive torso phantom and exposed to the magnetic fields of the system's applicators (whole body mat, cushion, and bar applicator). The detection thresholds of the implants were programmed to maximum sensitivity and both unipolar as well as bipolar electrode configurations were considered. The evaluation of possible interferences was derived from the internal event storages and pacing statistics recorded by the implants during exposure. Any "heart activity" recorded by the implants during exposure was interpreted as a potential interference, because the implant obviously misinterpreted the external interference signal as a physiological signal. Only cases without any recorded "heart activity" and with nominal pacing rates (as expected from the program parameter settings) of the implants were rated as "interference-free." Exposure to the whole body mat (peak magnetic induction up to 265 microT) did not show an influence on PMs and AICD in any case. The cushion applicator at the highest field intensity (peak magnetic induction up to 360 microT) led to atrial sensing defects in four PM models with unipolar electrode configuration. Under bipolar electrode configuration no disturbances occurred. The bar applicator led to sensing problems and consecutively reduced pacing rates in all tested PM models under unipolar electrode configuration and maximum field intensity (peak magnetic induction up to 980 microT). Bipolar electrode configuration resolved the problem. The investigated AICDs did not show malfunctions under any investigated condition. In conclusion, the examined PEMF therapy system did not interfere with the investigated implantable cardiac devices with bipolar electrode configuration. However, unipolar electrode configuration in pacemakers seems to be potentially hazardous during application of the examined PEMF therapy system.  相似文献   

8.

Background

A recent Cochrane meta-analysis did not confirm the benefits of fish and fish oil in the secondary prevention of cardiac death and myocardial infarction. We performed a meta-analysis of randomized controlled trials that examined the effect of fish-oil supplementation on ventricular fibrillation and ventricular tachycardia to determine the overall effect and to assess whether heterogeneity exists between trials.

Methods

We searched electronic databases (MEDLINE, EMBASE, The Cochrane Central Register of Controlled Trials, CINAHL) from inception to May 2007. We included randomized controlled trials of fish-oil supplementation on ventricular fibrillation or ventricular tachycardia in patients with implantable cardioverter defibrillators. The primary outcome was implantable cardioverter defibrillator discharge. We calculated relative risk [RR] for outcomes at 1-year follow-up for each study. We used the DerSimonian and Laird random-effects methods when there was significant heterogeneity between trials and the Mantel-Hanzel fixed-effects method when heterogeneity was negligible.

Results

We identified 3 trials of 1–2 years'' duration. These trials included a total of 573 patients who received fish oil and 575 patients who received a control. Meta-analysis of data collected at 1 year showed no overall effect of fish oil on the relative risk of implantable cardioverter defibrillator discharge. There was significant heterogeneity between trials. The second largest study showed a significant benefit of fish oil (relative risk [RR] 0.74, 95% confidence interval [CI] 0.56–0.98). The smallest showed an adverse tendency at 1 year (RR 1.23, 95% CI 0.92–1.65) and significantly worse outcome at 2 years among patients with ventricular tachycardia at study entry (log rank p = 0.007).

Conclusion

These data indicate that there is heterogeneity in the response of patients to fish-oil supplementation. Caution should be used when prescribing fish-oil supplementation for patients with ventricular tachycardia.There is a public perception that fish and fish oil can be recommended uniformly for the prevention of coronary artery disease.1–3 However, the scientific evidence is divided4,5 and official agencies have called for more research.6It is estimated that 0.5% of patients with coronary heart disease, 1% of patients with diabetes or hypertension and 2% of the general population at low risk of coronary heart disease take fish-oil supplements.7 In 2004, the price of fish oils overtook that of vegetable oils, and in 2006, the price rose to US$750 per ton.8 The value of fish oil as a nutraceutical in the European market was US$194 million in 2004, and it is anticipated that the price will continue to rise as availability declines.8 Canada is both a consumer and an exporter of fish oil, and it exported 15 000 tons in 2006.9The scientific debate over the clinical value of fish oil is highlighted by a recent Cochrane review, which concluded that long-chain omega-3 fatty acids (eicosapentaenoic acid and docosahexaenoic acid) had no clear effect on total mortality, combined cardiovascular events or cancer.4 Furthermore, another recent meta-analysis10 only showed a significant positive association between fish-oil consumption and prevention of restenosis after coronary angioplasty in a select subgroup after excluding key negative papers.11 Finally, the antiarrhythmic effect, which is proposed to be the principal mechanism of their benefit in cardiovascular disease, has not been demonstrated clearly in clinical trials.12–14We therefore performed a meta-analysis of randomized controlled trials that examined the effect of fish-oil supplementation in patients with implantable cardioverter defibrillators who are at risk of ventricular arrhythmia to determine the overall effect of fish oils. We also sought to investigate whether there was significant heterogeneity between trials.  相似文献   

9.
10.

Background

Survivors of out-of-hospital cardiac arrest are at high risk of recurrent arrests, many of which could be prevented with implantable cardioverter defibrillators (ICDs). We sought to determine the ICD insertion rate among survivors of out-of-hospital cardiac arrest and to determine factors associated with ICD implantation.

Methods

The Ontario Prehospital Advanced Life Support (OPALS) study is a prospective, multiphase, before–after study assessing the effectiveness of prehospital interventions for people experiencing cardiac arrest, trauma or respiratory arrest in 19 Ontario communities. We linked OPALS data describing survivors of cardiac arrest with data from all defibrillator implantation centres in Ontario.

Results

From January 1997 to April 2002, 454 patients in the OPALS study survived to hospital discharge after experiencing an out-of-hospital cardiac arrest. The mean age was 65 (standard deviation 14) years, 122 (26.9%) were women, 398 (87.7%) had a witnessed arrest, 372 (81.9%) had an initial rhythm of ventricular tachycardia or ventricular fibrillation (VT/VF), and 76 (16.7%) had asystole or another arrhythmia. The median cerebral performance category at discharge (range 1–5, 1 = normal) was 1. Only 58 (12.8%) of the 454 patients received an ICD. Patients with an initial rhythm of VT/VF were more likely than those with an initial rhythm of asystole or another rhythm to undergo device insertion (adjusted odds ratio [OR] 9.63, 95% confidence interval [CI] 1.31–71.50). Similarly, patients with a normal cerebral performance score were more likely than those with abnormal scores to undergo ICD insertion (adjusted OR 12.52, 95% CI 1.74–92.12).

Interpretation

A minority of patients who survived cardiac arrest underwent ICD insertion. It is unclear whether this low usage rate reflects referral bias, selection bias by electrophysiologists, supply constraint or patient preference.People who survive out-of-hospital cardiac arrest have an increased risk of recurrent arrest of 18%–20% in the first year.1,2 Three large randomized studies evaluated the use of implantable cardioverter defibrillators (ICDs) versus antiarrhythmic drugs in survivors of out-of-hospital cardiac arrest.3,4,5 The largest of the 3 studies involved 1016 patients and found a 39% relative risk reduction in mortality in the ICD group.3 The 2 smaller studies both reported nonsignificant reductions in mortality in the ICD group.4,5 Two recent meta-analyses showed that the use of ICDs was associated with significant and important increases in survival among cardiac arrest survivors: all-cause mortality was reduced by 23%–28% with their use for secondary prevention, and the rate of sudden cardiac death was reduced by 50% in both meta-analyses.6,7Guidelines from several national and international societies recommend insertion of ICDs in all survivors of cardiac arrest without a reversible cause.8,9 Despite advances in ICD insertion and technology, studies to date suggest that the utilization rate is low, at least in some settings.10,11 Several factors, including patient preference, physician referral, availability and cost, may contribute to the underutilization of ICDs.The Ontario Prehospital Advanced Life Support Study (OPALS)12,13 is a multiphase before–after study designed to systematically evaluate the effectiveness of various prehospital interventions for people experiencing cardiac arrest, trauma or respiratory arrest. As an extension of the OPALS study, we sought to determine the rate of ICD insertion among survivors of cardiac arrest, as well as the factors associated with ICD implantation.  相似文献   

11.
The delivery of implantable cardioverter defibrillator (ICD) therapy is sophisticated and requires the programming of over 100 settings. Physicians tailor these settings with the intention of optimizing ICD therapeutic efficacy, but the usefulness of this approach has not been studied and is unknown. Empiric programming of settings such as anti-tachycardia pacing (ATP) has been demonstrated to be effective, but an empiric approach to programming all VT/VF detection and therapy settings has not been studied. A single standardized empiric programming regimen was developed based on key strategies with the intention of restricting shock delivery to circumstances when it is the only effective and appropriate therapy. The EMPIRIC trial is a worldwide, multi-center, prospective, one-to-one randomized comparison of empiric to physician tailored programming for VT/VF detection and therapy in a broad group of about 900 dual chamber ICD patients. The trial will provide a better understanding of how particular programming strategies impact the quantity of shocks delivered and facilitate optimization of complex ICD programming.  相似文献   

12.
13.
14.
15.
16.

Background

Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs) to minimize inappropriate therapies (ITS), but this has not been completely successful.

Aim

Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS.

Method

A retrospective single-centre analysis of 250 patients with either dual chamber (DR) ICDs or biventricular ICDs (CRTDs) over a (41.9 ± 27.3) month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming.

Results

39 events of anti-tachycardial pacing (ATP) and/or shocks were identified in 20 patients (8% incidence rate among patients). The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%). Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43%) of the secondary indication group experienced inappropriate therapies.

Conclusions

The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation.  相似文献   

17.

Background

Implantable cardioverter defibrillators (ICDs) are designed to deliver shocks or antitachycardia pacing (ATP) in the event of ventricular arrhythmias. During follow-up, some ICD recipients experience the sensation of ICD discharge in the absence of an actual discharge (phantom shock). The aim of this study was to evaluate the incidence and predictors of phantom shocks in ICD recipients.

Methods

Medical records of 629 consecutive patients with ischaemic or dilated cardiomyopathy and prior ICD implantation were studied.

Results

With a median follow-up of 35 months, phantom shocks were reported by 5.1 % of ICD recipients (5.7 % in the primary prevention group and 3.7 % for the secondary prevention group; p=NS). In the combined group of primary and secondary prevention, there were no significant predictors of the occurrence of phantom shocks. However, in the primary prevention group, phantom shocks were related to a history of atrial fibrillation (p=0.03) and NYHA class <III (p=0.05). In the secondary prevention group, there were no significant predictors for phantom shocks.

Conclusion

Phantom shocks occur in approximately 5 % of all ICD recipients. In primary prevention patients, a relation with a history of atrial fibrillation and NYHA class <III were significant predictors for the occurrence of phantom shocks. In the secondary prevention patients, no significant predictors were found.  相似文献   

18.
19.
Electromagnetic interferences (EMI) deriving from electrical devices may affect implantable cardioverter defibrillators (ICD). Improved algorithms have been developed in order to minimize adverse effects. However, caution should be still recommended in ICD recipients when handling electrical devices. Here we describe the case of an ICD patient with recurrent syncopal episodes due to inhibition of pacing by oversensing of electrical noise from a not properly grounded washing machine.  相似文献   

20.
Commercially available cardiac pacemakers and implantable cardioverters/defibrillators (ICDs) predominantly use an intracardiac-derived electrocardiogram (ECG) for the detection of arrhythmias. To achieve automatic control of the heart frequency in accordance with cardiovascular strain and improved detection of life-threatening arrhythmias, it is desirable to monitor the heart by an input signal correlated with the hemodynamic state. One possible approach to derive such a signal is to measure the inotropy (mechanical contraction strength of the heart muscle). For this purpose, an optoelectronic measurement system has been designed. The fundamental function of the system has been shown in earlier investigations using an isolated beating pig heart. In this paper the design of two algorithms for use in pacemakers and ICDs based on a fiber optic sensor signal is presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号