首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A 51-year-old male developed recurrent episodes of palpitations and pre-syncope after surgical aortic valve replacement. Electrocardiograms after surgery revealed a wide complex tachycardia with alternating left bundle branch and right bundle branch block morphologies. An electrophysiology study (EPS) demonstrated typical bundle branch reentry ventricular tachycardia (BBRVT) treated successfully with right bundle ablation. We demonstrate the key diagnostic features of BBRVT on EPS, describe the circuit of BBRVT with explanation of the HV pseudointerval, and highlight the association of BBRVT and valve replacement.  相似文献   

2.
Incisional sustained tachycardias are frequent in patients who have undergone a surgical repair of interatrial defect. A 43-year-old woman with drug refractory, highly symptomatic, persistent atrial tachycardia in the last year, was referred to our unit for catheter ablation. The patient had undergone a cardiac operation for repairing interatrial secundum ostium type defect with a patch five years before. A previous radiofrequency ablation procedure had been performed for common atrial flutter. We describe a case of incisional atrial tachycardia ablation guided by the new EnSite NavX system equipped with a new electroanatomic mapping system.  相似文献   

3.
Identification of the critical isthmus of the reentrant tachycardia is essential to maximize the effect of catheter ablation (CA) and to minimize the myocardial injury of CA. An 81-year-old woman presented recurrent palpitations after CA of atrial fibrillation (AF) and atrial tachycardia (AT). She had moderate aortic valve stenosis and coronary artery disease. She had received a pulmonary vein isolation, left atrial (LA) posterior wall isolation, and LA anterior linear ablation for atrial fibrillation 1 year prior. At the start of the procedure, she was in sinus rhythm. Atrial burst pacing induced an AT (230msec). High-density mapping revealed a figure-of-eight activation pattern within the LA appendage (LAA), accounting for 99% of the tachycardia cycle length. The critical isthmus was identified at the mid LAA and the local electrogram of the critical isthmus was not fractionated. A single radiofrequency application at the critical isthmus of the AT, terminated the AT. She was free from any ATs for 28 months.Radiofrequency ablation of the localized reentrant AT was usually performed targeting long fractionated electrograms. In our case, the local electrogram at the critical isthmus was not fragmented compared with the LAA distal part. Long fractionated electrograms were recorded at a more distal part of the LAA than the common isthmus and we could avoid the potential risk of a perforation. A recent developed 3-dimensional electro-anatomical mapping system can identify the critical isthmus and allow us to select a new therapeutic strategy for a critical isthmus ablation of an AT within the LAA.  相似文献   

4.
The right atrial appendage can be the origin of focal atrial tachycardias. Their ablation can be challenging owing to the complexity of the appendage anatomy. To our knowledge, we describe the first successful solid tip cryoablation of a focal tachycardia within the right atrial appendage in a patient presenting with tachycardia-induced cardiomyopathy.  相似文献   

5.
A 74-year-old man after multiple mitral valve surgeries underwent catheter ablation of a bi-atrial tachycardia (BiAT). Ultra-high resolution activation mapping exhibited a reentrant circuit propagating around the inferior to anterior mitral annulus and right atrial (RA) septum with two interatrial connections. At the transeptal puncture site, continuous fractionated electrograms were recorded during the BiAT, and entrainment pacing revealed a post-pacing interval similar to the tachycardia cycle length, which suggested that the interatrial conduction from the RA to the left atrium (LA) was located just at the transseptal puncture site. A radiofrequency application inside the transseptal puncture hole could successfully eliminate the BiAT. The ablation target for BiATs propagating around the mitral annulus and RA septum is generally the anatomical mitral isthmus (MI). Since the present case had multiple incisions on both the RA and LA septum due to mitral valve surgeries, there was the possibility of the occurrence of a BiAT including the RA and LA septum after performing an MI linear ablation. Therefore, the preferable ablation target for the BiAT in the present case appeared to be the interatrial connection. Ultra-high resolution detailed mapping not only on the atrial endocardium but also in the transseptal puncture hole may be useful for identifying a critical interatrial connection of BiAT circuits.  相似文献   

6.
A case of macro-reentrant tachycardia associated with a box lesion after thoracoscopis left atrial surgical atrial fibrillation (AF) ablation yet to be described. The goal was to clarify the mechanisms and electrophysiological characteristics of this type of tachycardia.A patient was admitted for an EP study following surgical thoracoscopic AF ablation (box lexion formation by right-sided Cobra thoracoscopic ablation). Thoracoscopic ablation was done as the first step of the hybrid ablation approach to the persistent AF; the second step was the EP study. At the EP study, he presented with incessant regular tachycardia (cycle length of 226 ms). An EP study with conventional, 3D activation and entrainment mapping was done to assess the tachycardia mechanism. Two conduction gaps in the superior line (roofline) between the superior pulmonary veins were discovered. The tachycardia was successfully treated with a radiofrequency application near the gap close to the left superior pulmonary vein; however, following tachycardia termination, pulmonary vein isolation was absent. A second radiofrequency application, close to the roof of the right superior pulmonary, vein closed the gap in the box and led to the isolation of all 4 pulmonary veins. No atrial tachycardia recurred during the 6-month follow-up.Conduction gaps in box lesion created by thoracospcopic ablation can present as a novel type of man-made tachycardia after surgical ablation of atrial fibrillation. Activation and entrainment mapping is necessary for an accurate diagnosis.  相似文献   

7.
The right atrial appendage (RAA) is a rare site of focal atrial tachycardia (AT). Sometimes, catheter ablation cannot successfully be accomplished at this location due to the difficulty in reaching the exact ablation site as well as the associated possible life-threatening complications like pericardial tamponade or perforation. Although radiofrequency (RF) ablation is preferred for the treatment of RAA tachycardias, alternative tools may be required in rare instances. This report presents a case of RAA tachycardia that was not terminated by RF ablation, instead, has been successfully ablated using cryoballoon. In addition, an overview of the literature and therapeutic options for the AT originating from RAA have also been included.  相似文献   

8.
目的:分析心脏瓣膜置换同期行双极射频消融改良迷宫术治疗房颤的术后中远期疗效及其影响因素。方法:选取2007年7月至2010年12月于我院行心脏瓣膜置换同期行双极射频消融改良迷宫术治疗房颤的72例患者,术后随访3至6年,获得患者术后十二导联心电图、24 h动态心电图和心脏彩超结果,并且记录术后药物应用、相关并发症、心功能恢复情况及生活质量是否改善等情况。根据心电图结果,将患者分为窦性心律组与非窦性心律组,应用统计学方法比较两组患者术前相关因素是否有差异。结果:截止至随访终点,有效随访的68例患者中窦性心律维持率为63.2%。单因素分析显示术前房颤病程、术前左室射血分数、是否合并三尖瓣成形或置换是影响手术效果的影响因素,多因素分析显示术前房颤病程、合并三尖瓣成形或置换是影响手术效果的危险因素。结论:心脏瓣膜置换同期行双极射频消融改良迷宫术治疗房颤的中晚期疗效好,术后并发症少,能够有效防止血栓栓塞,术前房颤病程长、合并三尖瓣成形或置换的患者术后中远期效果相对较差。  相似文献   

9.
Ablation of cavotricuspid isthmus flutter and atrial tachycardia in a complex substrate has never been reported using remote navigation via superior approach. Venous access was obtained via right internal jugular for ablation and left subclavian for duodecapolar catheter placement into the coronary sinus. In a posttransplant patient presenting with both regular and irregular tachycardia, both cavotricuspid isthmus flutter in the donor and atrial tachycardia in the recipient was mapped using a two catheter approach. Successful ablation of typical atrial flutter and anastomotic block was achieved. This is the first report of successful ablation of cavotricuspid isthmus flutter and posttransplant atrial tachycardia using magnetic navigation via superior approach. Using only two catheters, this approach is logical and feasible in complex substrates with interrupted inferior venous access.  相似文献   

10.
目的:分析瓣膜手术同期射频消融改良迷宫术治疗心脏瓣膜病并发房颤患者的疗效及对血清细胞因子的影响。方法:将80例心脏瓣膜病并发房颤患者依据简单随机法分为对照组和观察组,每组40例。对照组采用心脏瓣膜置换术治疗,观察组采用心脏瓣膜置换术同期射频消融改良迷宫术治疗,比较两组窦性心律转复情况,手术情况,手术前后心功能、血清金属蛋白酶组织抑制因子-1(TIMP-1)、基质金属蛋白酶-1(MMP-1)和基质金属蛋白酶-9(MMP-9)水平的变化以及术后并发症的发生情况。结果:观察组术后当天、术后1月、术后3月及术后6月的窦性心律转复率均显著高于对照组(P0.05),体外循环时间、主动脉阻断时间及术后24 h引流量均明显多于对照组(P0.05)。两组呼吸机使用时间和监护室时间比较差异无统计学意义(P0.05)。术后6个月,两组左室舒张末期内径、左室收缩末期内径、血清MMP-1和MMP-9水平均较术前显著下降,且观察组以上指标明显低于对照组;两组LVEF及血清TIMP-1水平较术前显著上升,且观察组以上指标均显著高于对照组(P0.05)。两组术后均无严重并发症发生。结论:瓣膜手术同期射频消融改良迷宫术治疗心脏瓣膜病并发房颤安全有效,早期窦性心律的转复率高,且可改善患者血清TIMP-1、MMP-1、MMP-9水平。  相似文献   

11.
Idiopathic fascicular ventricular tachycardia is an important cardiac arrhythmia with specific electrocardiographic features and therapeutic options. It is characterized by relatively narrow QRS complex and right bundle branch block pattern. The QRS axis depends on which fascicle is involved in the re-entry. Left axis deviation is noted with left posterior fascicular tachycardia and right axis deviation with left anterior fascicular tachycardia. A left septal fascicular tachycardia with normal axis has also been described. Fascicular tachycardia is usually seen in individuals without structural heart disease. Response to verapamil is an important feature of fascicular tachycardia. Rare instances of termination with intravenous adenosine have also been noted. A presystolic or diastolic potential preceding the QRS, presumed to originate from the Purkinje fibers can be recorded during sinus rhythm and ventricular tachycardia in many patients with fascicular tachycardia. This potential (P potential) has been used as a guide to catheter ablation. Prompt recognition of fascicular tachycardia especially in the emergency department is very important. It is one of the eminently ablatable ventricular tachycardias. Primary ablation has been reported to have a higher success, lesser procedure time and fluoroscopy time.  相似文献   

12.
Idiopathic outflow tract arrhythmias (ventricular tachycardias or symptomatic premature ventricular contractions; OT-VT/PVCs) can originate from the left ventricular (LV) epicardium (Epi-VT/PVCs), and radiofrequency (RF) energy applications from the aortic sinus of Valsalva can eliminate Epi-VT/PVCs in selected patients. Among the various ECG findings, the R-wave duration index and R/S amplitude index in leads V1 or V2 are useful for identifying Epi-VT/PVCs, and the Q-wave ratio of leads aVL to aVR and S-wave amplitude in lead V1 are useful for differentiating between an Epi-VT/PVC originating from the LV epicardium remote from the left sinus of Valsalva (LSV) and that from the LSV. Tissue tracking imaging is a promising modality for identifying the origin of OT-VT/PVCs and for differentiating between an Epi-VT/PVC originating from the LV epicardium remote from the LSV and that from the LSV. If the origin of the Epi-VT/PVC is identified within the LSV, coronary and aortic angiography should be performed to assess the anatomic relationships between the Epi-VT/PVC origin and coronary arteries and aortic valve before the RF energy delivery. To avoid potential complications, RF ablation should be performed at the LSV using a maximum power of 35 watts and maximum temperature of 55 degrees C. Epicardial mapping through the coronary venous system and the presence of potentials recorded from the ablation site within the LSV and their changes before and after the RF energy applications may be useful for diagnosing Epi-VT/PVCs or predicting a successful catheter ablation from the LSV.  相似文献   

13.
Focal left atrial tachycardia (FLAT) although a common cause of supraventricular tachycardia(SVT) among children, the one''s arising from left atrial appendage (LAA) present a unique challenge for successful ablation because of anatomical location. We present two children with FLAT arising from the epicardial LAA, successfully mapped and ablated through percutaneuous epicardial approach.  相似文献   

14.
Incessant focal atrial tachycardia may be encountered in the pediatric age group although it is rarely seen. Ablation using radiofrequency or cryothermal energy is the preferred method for drug-resistant cases. Recently, 3D electroanatomic mapping systems have been increasingly used for mapping and ablation. In this report, we presented, for the first time, a pediatric case with incessant focal atrial tachycardia originating from the non-coronary aortic sinus and ablated using 3D electroanatomic mapping system.  相似文献   

15.
BackgroundOesophageal changes and injuries were recorded after atrial fibrillation(AF) ablation procedures. The reduction of power in the posterior left atrial(LA) wall(closest to the oesophagus) and the monitoring of temperature in the oesophagus(OE) reduced oesophageal injuries. The intracardiac-echocardiography(ICE) with a Cartosound module provides two-dimensional imaging (2D) to assess detailed cardiac anatomy and its relationship with the OE. The aim of this study was to highlight the safety and feasibility of 3D-reconstruction of the oesophageal course in left atrial catheter ablation(CA) procedures without OE temperature probe or quadripolar catheter to guide ICE OE reconstruction.Methods180 patients(PT) underwent left atrial ablation. AF ablation were 125(69.5%); incisional left atrial tachycardias(IAFL) were 37(20.6%); left atrial tachycardias(LAT) were 19(10.6%). The LA and pulmonary vein anatomies were rendered by traditional electroanatomic mapping(EAM) and merged with an ICE anatomic map. In 109 PT ICE imaging was used to create a geometry of the OE(group A). A quadripolar catheter was used in 71 PT to show OE course associated to ICE(group B).ResultsAblation energy delivery was performed outside the broadest OE anatomy borders. The duration of procedures was longer in group B vs group A Fluoroscopy time was lower in Group A than Group B(Group A 7 ± 3.2 vs 19.2 ± 2.4 min; p < 0.01).ConclusionsOE monitoring with ICE is safe and feasible. Oesophageal anatomy is complex and variable. Many PT will have a broad oesophageal boundary, which increases the risk of untoward thermal injury during posterior LA ablation. ICE with 3D construction of the OE enhances border detection of the OE, and as such, should decrease the risk of oesophageal injury by improving avoidance strategies without intra-oesophageal catheter visualization.  相似文献   

16.
Ablation of macroreentrant atrial tachycardia in patients with mechanical prosthetic valves represents a challenge for electrophysiologists, because of the complexity of the procedure and the potential complications. Moreover, the need for fluoroscopy in this type of procedure is greater, due to the risk of interference between the prosthetic valve and the ablation or mapping catheter. We present two cases of patients with mechanical prosthetic valves and atrial flutter who underwent successful ablation with no complications using the CartoUnivu? tool, which integrates the electroanatomical map and the fluoroscopy image.  相似文献   

17.
目的:分析经食道心房调搏术(TEAP)及食道内心电图(EECG)在心律失常中的应用价值。方法:选取2018年6月至2019年12月于我院行食道心电图及经食道调搏的患者189例,其中男80例,女109例,年龄11~83岁。结果:54例为房室结折返性心动过速(AVNRT),34例为房室折返性心动过速(AVRT),8例为房性心动过速(AT),4例为心房扑动(AF),6例为心房颤动(Af),5例为室性心过速,78例为室早或其他。共105例心律失常患者拟行食道心房调搏终止心动过速,所有AVNRT和AVRT患者及17例AT患者经食道心房调搏S1S1成功转为窦律,50例AVNRT、32例AVRT、6例AT、3例AF及2例VT患者通过射频消融术成功根治。其中1例11岁AT患者因无法耐受食道调搏,未能转为窦律,患者经静推普罗帕酮后次日转为窦律。共97例患者拟行食道心房调搏诱发,共49例诱发出心动过速,1例左后分支型室速经静滴异丙肾上腺素后诱发心动过速,且仍需静滴异丙肾上腺素后经心房食道调博终止心动过速,后经射频消融术成功根治。结论:TEAP及EECG可用于复杂心律失常的诊断及治疗,是一种相对安全、临床容易掌握的技术,值得推广。  相似文献   

18.
An average follow-up period of 16 patients was 28 months following an implantation of the artificial aortic valve for its insufficiency. In 10 operated patients who were able to continue their occupation exercise tolerance increased by two classes, according to NYHA. Blood pressure gradient decreased significantly from 61.8 to 37.5 mmHg, cardiac volume index decreased from 639 to 602 ml/m2. Echocardiographically measured muscle mass of the left ventricle, end-diastolic and end-systolic volumes, and the left atrial dimensions decreased significantly following surgery. A significance of the relation of the left ventricle volume to its mass <4 as a prognostic factor in aortic valve replacement has also been confirmed.  相似文献   

19.
Monomorphic ventricular tachycardia (VT) and symptomatic monomorphic PVCs originating from the region of the right and left outflow tracts are increasingly treated by radiofrequency (RF) catheter ablation. Technical difficulties in catheter manipulation to access these outflow tract areas, very accurate mapping and reliable catheter stability are key issues for a successful treatment in this vulnerable region. VT ablation from the aortic sinus cusp (ASC) in particular carries a significant risk of perforation, of creating left coronary artery injury and of damage to the aorta and the aortic valve. This case series describes RF ablation of VT originating in the outflow region using the remote magnetic navigation system (MNS). Potential advantages of the MNS are catheter flexibility, steering accuracy and reproducibility to navigate to a desired location with a low probability of perforating the myocardium. This report supports the idea of using advanced MNS technology during RF ablation in regions which are difficult to reach and thin walled, such as parts of the outflow tract and the ASC. (Neth Heart J 2009;17:245–9.)  相似文献   

20.
This study characterizes left ventricular performance early after aortic valve replacement for severe isolated aortic regurgitation. Gated radionuclide ventriculography studies in 13 patients showed that left ventricular end-diastolic volume was reduced after surgery and that ejection fraction dropped significantly. Despite the fall in ejection fraction, the postoperative cardiac index was significantly greater than the preoperative value. Radionuclide ventriculography is a useful and reliable means of noninvasively assessing left ventricular function soon after aortic valve replacement for aortic regurgitation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号