首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 8 毫秒
1.
The coefficient of microwave power absorption by a single-sided multipactor discharge on a dielectric surface is studied analytically and numerically as a function of the incident microwave power. It is shown that taking into account electron reflections from the dielectric surface leads to a substantial increase in the absorption coefficient. The analytical and numerical results are compared with experimental data.  相似文献   

2.
3.
Liu Q  Cai H  Xu Y  Li Y  Li R  Wang P 《Biosensors & bioelectronics》2006,22(2):318-322
Human olfactory system can distinguish thousands of odors. In order to realize the biomimetic design of electronic nose on the principle of mammalian olfactory system, this article reports an olfactory cell-based biosensor as a real bionic technique for odorants detection. Effective cultures of olfactory receptor neurons and olfactory bulb cells have been achieved on the semiconductor chip. Using light-addressable potentiometric sensor (LAPS) as sensing chip to monitor extracellular potential of the neurons, the response under stimulations of the odorants or neurotransmitters, such as acetic acid and glutamic acid, was tested. The results demonstrate that this kind of hybrid system of LAPS and olfactory neurons, which is sensitive to odorous changes, has great potential and is promising to be used as a novel neurochip of bioelectronic nose for detecting odors.  相似文献   

4.
5.
6.
Bilirubin detection plays a major role in healthcare. Its high concentration in human serum is lethal and must be determined accurately. Clinically, it is vital for assessing patients with deleterious health conditions such as jaundice or icterus, hepatitis, mental disorders, cerebral palsy and brain damage especially in the case of neonates. In evaluating the drawbacks regarding the conventional methodology of bilirubin detection, there is need for a superior analytical tool. Bilirubin oxidase (BOx)-based sensors have been designed for the ultrasensitive analysis of bilirubin and quality deliverance of treatment and this review highlights the different mechanisms of bilirubin detection using different modified electrodes. Further, it also addresses the exploitation of highly attractive electrocatalytic properties of elite nanoparticles such as gold and zirconia- coated silica nanoparticles in enhancing the reproducibility and specificity of bilirubin biosensors.  相似文献   

7.
A novel ratiometric fluorescent receptor (Z)‐2‐(4‐[diethylamino]‐2‐hydroxybenzylideneamino) pyridine‐3‐carbaldehyde (3) bearing one phenolic OH and one aldehyde group as recognition sites was synthesized and characterized. The anion recognition behaviour of receptor 3 was evaluated by various spectroscopic (UV‐visible, fluorescence and 1H nuclear magnetic resonance) methods and was validated by computational studies. The receptor showed fast response time, excellent selectivity and reproducibility towards iodide ion detection among the other surveyed anions, with a binding constant of 6.12 × 104 M?1 and a detection limit of 0.24 μM, thus confirming its potential applicability as a fluorescent sensor for iodide Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
Previous research has shown that lactate dehydrogenase (LDH) was competitively inhibited by pentachlorophenol (PCP) and a modified assay produced a detection limit of 1 μM (270 μg l−1). This work used spectrophotometric rate-determination but in order to move towards biosensor development the selected detection method was electrochemical. The linkage of LDH to lactate oxidase (LOD) provided the electroactive species, hydrogen peroxide. This could be monitored using a screen-printed carbon electrode (SPCE) incorporating the mediator, cobalt phthalocyanine, at a potential of +300 mV (vs. Ag/AgCl). A linked LDH/LOD system was optimised with respect to inhibition by PCP. It was found that the SPCE support material, PVC, acted to reduce inhibition, possibly by combining with PCP. A cellulose acetate membrane removed this effect. Inhibition of the system was greatest at enzyme activities of 5 U ml−1 LDH and 0.8 U ml−1 LOD in reactions containing 246 μM pyruvate and 7.5 μM NADPH. PCP detection limits were an EC10 of 800 nM (213 μg l−1) and a minimum inhibition detectable (MID) limit of 650 nM (173 μg l−1). The inclusion of a third enzyme, glucose dehydrogenase (GDH), provided cofactor recycling to enable low concentrations of NADPH to be incorporated within the assay. NADPH was reduced from 7.5 to 2 μM. PCP detection limits were obtained for an assay containing 5 U ml−1 LDH, 0.8 U ml−1 LOD and 0.1 U ml−1 GDH with 246 μM pyruvate, 400 mM glucose and 2 μM NADPH. The EC10 limit was 150 nM (39.9 μg l−1) and the MID was 100 nM (26.6 μg l−1). The design of the inhibition assays discussed has significance as a model for other enzymes and moves forward the possibility of an electrochemical biosensor array for pollution monitoring.  相似文献   

9.
In this study we examined the possibilities of implementing direct and competitive immunoassay formats for small and large molecule detection on a microarray, using IBIS imaging surface plasmon resonance (iSPR) system. First, IBIS iSPR optics performance was evaluated. Using a glycerol calibration curve on underivatized surface we observed high baseline variability, but uniform and robust sensitivity between hundred regions of interest. Further on, a direct immunoassay for bovine IgG detection and a competitive immunoassay for gentamicin and neomycin were developed. The direct immunoassay for bovine IgG detection in a microarray format showed poor sensitivity in comparison to the assay performed in Biacore 3000, due to low immobilization efficiency on spots. The competitive immunoassay for parallel gentamicin and neomycin detection in a microarray format displayed sensitivity in the ngmL(-1) range, comparable with the sensitivity achieved in Biacore 3000 and in the range of maximum residue limits in milk, established in the European Union. We expect that, utilization of the IBIS iSPR system for food analysis, by screening high and low molecular weight compounds, will allow rapid and simultaneous detection of various ingredients and contaminants, providing the end-user with a detailed food profile. However, assay transfer from conventional SPR biosensors to the imaging microarray platform also presents new challenges, such as sufficient immobilization on spots, that must be addressed in future studies.  相似文献   

10.
A theoretical model is presented for growth and remodeling in the developing embryonic heart. The model is a thick-walled tube composed of two layers of orthotropic pseudoelastic material. The analysis includes stress and strain dependent volumetric growth, with changes in material properties specified to reflect the evolving structure of the heart wall. For use in model validation, experimental measurements of ventricular opening angles are reported for 3–4-day old chick embryos under control and pressure overload conditions. Owing to changes in residual stress in the overloaded heart, the opening angle decreased from 31 ± 10° to −8 ± 12° (mean ± SD) within 12 h and then increased slightly. The opening angle at 12 h was significantly less than the control value. With an appropriate choice of parameters, the model yields reasonable agreement with these and other published opening angle data, as well as with temporal changes in lumen radius, wall thickness, epicardial strains, and pressure–volume curves during development before and after birth. Received: 26 November 2001 / Accepted: 21 December 2001  相似文献   

11.
The dielectric constant (epsilon) and refractive index (n) of a bilayer lipid membrane is determined from the known values of the polarizabilities of the carbon-carbon and carbon-hydrogen bonds. It is assumed that the hydrocarbon chains are hexagonally arranged in an all-trans conformation perpendicular to the plane of the membrane. The only variable in the calculation is the average separation between the chains and the theory relates epsilon to this separation. The calculation and results differ significantly from those presented in a 1968 publication by Ohki. It is shown that a thin membrane is not homogeneously polarized by the applied field. This effect is analysed and the dependence of epsilon on the membrane thickness is determined. The theoretical results are in good quantitative agreement with experimental measurements on bulk paraffins and on oriented multilayers of saturated fatty acids. The most important conclusion is that the dielectric constant for an applied field perpendicular to the membrane (which is the appropriate value for capacitance measurements) differs by only a few percent from the value for the macroscopic (bulk) liquid hydrocarbon. Thus the dielectric constant of a bilayer membrane can be approximated by the value for the appropriate bulk hydrocarbon.  相似文献   

12.
A theoretical and experimental study of the oscillations of a space-charge cloud in a magnetron-injection gun of a powerful relativistic gyrotron has been performed. The charge storage occurs via electron-beam magnetic compression of the reflection of a part of the electrons having the highest transverse velocities from a magnetic mirror. It has been established that at high values of the compression coefficient the beam loses its stability that finally leads to the appearance of the beam current modulation at the frequency of the longitudinal oscillations of an electron beam in an adiabatic trap. According to the numerical simulations, the energy spread in the formed beam under these conditions reaches 4.6%, which is higher by an order of magnitude than that due to the space-charge effect in the beam transported along the metal tube.  相似文献   

13.
Dybal J  Ehala S  Kasicka V  Makrlík E 《Biopolymers》2008,89(12):1055-1060
The interactions of valinomycin, macrocyclic depsipeptide antibiotic ionophore, with ammonium cation NH4+ have been investigated. Using quantum mechanical density functional theory (DFT) calculations, the most probable structure of the valinomycin-NH4+ complex species was predicted. In this complex, the ammonium cation is bound partly by three strong hydrogen bonds to three ester carbonyl oxygen atoms of valinomycin and partly by somewhat weaker hydrogen bonds to the remaining three ester carbonyl groups of the valinomycin ligand. The strength of the valinomycin-NH4+ complex was evaluated experimentally by capillary affinity electrophoresis. From the dependence of valinomycin effective electrophoretic mobility on the ammonium ion concentration in the background electrolyte, the apparent binding (association, stability) constant (Kb) of the valinomycin-NH4+ complex in methanol was evaluated as log Kb = 1.52 +/- 0.22.  相似文献   

14.
15.
A set of selected acetophenone derivatives was investigated using absorption and emission spectroscopy, laser flash photolysis and DFT calculations. The triplet state lifetimes and the activation energy of the cleavage reaction were measured. Computed triplet-triplet absorption spectra were found in very good agreement with the experimental ones. Bond dissociation energies, activation energies, partial charges, ground state geometries were calculated. The transition state theory TST was successfully used to calculate the cleavage rate constants: a very good correlation was found between the experimental and the calculated values. It is found that the entropy change influences the preexponential factor. This study also points out the role of the partial charges in the transition state, although this effect alone does not account for the reaction rate constants.  相似文献   

16.
A novel technique is described which comprises a base-specific DNA duplex formation at a lipid bilayer-H(2) O-phase boundary layer. Two different probes of oligonucleotides both carrying a double-tailed lipid at the 5'-terminus were incorporated into stable artificial lipid bilayers separating two compartments (cis/trans-channel) of an optically transparent microfluidic sample carrier with perfusion capabilities. Both the cis- and trans-channels are filled with saline buffer. Injection of a cyanine-5-labeled target DNA sequence, which is complementary to only one of the oligonucleotide probes, into the cis-channel, followed by a thorough perfusion, leads to an immobilization of the labeled complementary oligonucleotide on the membrane as detected by single-molecule fluorescence spectroscopy and microscopy. In the case of fluorescent but non-complementary DNA sequences, no immobilized fluorescent oligonucleotide duplex could be detected on the membrane. This clearly verifies a specific duplex formation at the membrane interface.  相似文献   

17.
Recently enzyme immobilization techniques have been proposed that are mainly founded on the formation of an enzyme-gel layer onto the active surface of an ultrafiltration membrane within an unstirred ultrafiltration cell. If the membrane molecular-weight cutoff is less than the enzyme molecular weight and hence such as to completely prevent enzyme permeation (once the enzyme solution has been charged into the test cell and pressure applied to the system), a time progressive increase in enzyme concentration takes place at the upstream membrane surface that can eventually lead to gelation and hence to enzyme immobilization. However, depending on the total enzyme amount fed, the maximum enzyme concentration achieved in the unsteady state could be less than the gelation level. In this situation, no immobilization occurs and the enzyme still remains in the soluble form although it is practically confined within a limited region immediately upstream the membrane and at fairly high concentrations. In this paper, the experimental conditions that allow gelling to occur are discussed together with a theoretical analysis of the soluble enzyme membrane reactor which is obtained when no gelling takes place. Such a system could be usefully employed in performing kinetic analyses at high enzyme concentration levels that are still in the soluble form.  相似文献   

18.
The amplitude-frequency dependence of the polarizability of erythrocytes, yeast cells, and latex particles in the range of 1–106 Hz was studied by the method of dielectrophoresis (DEP). Positive DEP of erythrocytes and yeast cells in a frequency range of 60–100 Hz was revealed. The positive DEP of cells in the given range is theoretically explained by appearance of a great number of transverse pores through the membrane and wall of the cell.  相似文献   

19.
The detection performance of conventional surface plasmon resonance (SPR) biosensors is limited to a 1 pg/mm(2) surface coverage of biomolecules, and consequently, such sensors struggle to detect the interaction of small molecules in low concentrations. The present study is attempted to propose the use of a novel SPR biosensor with Au nanoclusters embedded in a dielectric film to achieve a 10-fold improvement in the resolution performance. A co-sputtering method utilizing a multi-target sputtering system is used to fabricate the present dielectric films (SiO(2)) with embedded Au nanoclusters. It is shown that the sensitivity of the developed SPR biosensor can be improved by adjusting the size and volume fraction of the embedded Au nanoclusters in order to control the surface plasmon effect. The present gas detection and DNA hybridization experimental results confirm that the proposed Au nanocluster-enhanced SPR biosensor provides the potential to achieve an ultrahigh-resolution detection performance of approximately 0.1 pg/mm(2) surface coverage of biomolecules.  相似文献   

20.
D Desnica 《Biopolymers》1979,18(7):1685-1690
The concentration dependence of the dielectric dispersion between 1 kHz and 0.5 MHz was investigated for dense hemoglobin solutions. The concentration was varied between 4 and 26 mM/l. per heme. From the characteristic changes in dielectric parameters at some threshold concentration, we observe that the association of hemoglobin macromolecules occurs. This statement is also confirmed by viscosity measurement data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号