首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Liver tumors are common and imaging methods, particularly magnetic resonance imaging (MRI), play an important role in their non-invasive diagnosis. Previous studies have shown that detection of liver tumors can be improved by injection of two different MR contrast agents. Here, we developed a new contrast agent, Gd-manganese-doped magnetism-engineered iron oxide (Gd-MnMEIO), with enhancement effects on both T1- and T2-weighted MR images of the liver. A 3.0T clinical MR scanner equipped with transmit/receiver coil for mouse was used to obtain both T1-weighted spoiled gradient-echo and T2-weighted fast spin-echo axial images of the liver before and after intravenous contrast agent injection into Balb/c mice with and without tumors. After pre-contrast scanning, six mice per group were intravenously injected with 0.1 mmol/kg Gd-MnMEIO, or the control agents, i.e., Gd-DTPA or SPIO. The scanning time points for T1-weighted images were 0.5, 5, 10, 15, 20, 25, and 30 min after contrast administration. The post-enhanced T2-weighted images were then acquired immediately after T1-weighted acquisition. We found that T1-weighted images were positively enhanced by both Gd-DTPA and Gd-MnMEIO and negatively enhanced by SPIO. The enhancement by both Gd-DTPA and Gd-MnMEIO peaked at 0.5 min and gradually declined thereafter. Gd-MnMEIO (like Gd-DTPA) enhanced T1-weighted images and (like SPIO) T2-weighted images. Marked vascular enhancement was clearly visible on dynamic T1-weighted images with Gd-MnMEIO. In addition, the T2 signal was significantly decreased at 30 min after administration of Gd-MnMEIO. Whereas the effects of Gd-MnMEIO and SPIO on T2-weighted images were similar (p = 0.5824), those of Gd-MnMEIO and Gd-DTPA differed, with Gd-MnMEIO having a significant T2 contrast effect (p = 0.0086). Our study confirms the feasibility of synthesizing an MR contrast agent with both T1 and T2 shortening effects and using such an agent in vivo. This agent enables tumor detection and characterization in single liver MRI sections.  相似文献   

2.
《Translational oncology》2020,13(1):92-101
To evaluate hepatobiliary-specific contrast agent (CA) mangafodipir trisodium (Mn-DPDP)–enhanced magnetic resonance imaging (MRI) for predicting the therapeutic efficacy of the vascular disrupting agent combretastatin A4 phosphate (CA4P) in rats with primary and secondary liver tumors, 36 primary hepatocellular carcinomas (HCCs) were raised by diethylnitrosamine gavage in 16 male rats, in 6 of which one rhabdomyosarcomas (R1) was intrahepatically implanted as secondary liver tumors. On a 3.0T MR scanner with a wrist coil, tumors were monitored weekly by T2-/T1-weighted images (T2WI/T1WI) and characterized by Mn-DPDP-enhanced MRI. CA4P-induced intratumoral necrosis was depicted by nonspecific gadoterate meglumine (Gd-DOTA)–enhanced MRI before and 12 h after therapy. Changes of tumor-to-liver contrast (ΔT/L) on Mn-DPDP-enhanced images were analyzed. In vivo MRI findings were verified by postmortem microangiography and histopathology. Rat models of primary HCCs in a full spectrum of differentiation and secondary R1 liver tumors were successfully generated. Mn-DPDP-enhanced ΔT/L was negatively correlated with HCC differentiation grade (P < 0.01). After treatment with CA4P, more extensive tumoral necrosis was found in highly differentiated HCCs than that in moderately and poorly differentiated ones (P < 0.01); nearly complete necrosis was induced in secondary liver tumors. Mn-DPDP-enhanced MRI may help in imaging diagnosis of primary and secondary liver malignancies of different cellular differentiations and further in predicting CA4P therapeutic efficacy in primary HCCs and intrahepatic metastases.  相似文献   

3.
ObjectivesBrain neoplasms or intracranial tumors, which are more common in older adults, can affect individuals of any age including pediatric and children. Exposure to carcinogenic agents including ionizing radiation and family history is one of the main causes of the disease. Early diagnosis is crucial to avoid prolonged. patients' suffering. The aim of the study was to efficiently recognize the brain tumors from the other brain tissues which include grey and white matter as well as cerebrospinal fluid (CSF).Materials and methodsThis study was performed using axial, sagittal and coronal views for fifty brain tumor patients randomly selected from a set of 200 patients, with a “control” set consisting of images showing no sign of disease; and the “test” brain MRI images for patients diagnosed with brain tumor. The study includes both genders with age ranging from 18 years to 83 years old, (56.5 ± 17.2). The brain images were acquired using a standard head coil Philips Intera 1.5 Tesla machine (USA). The thickness of each section in the entire sequence was 8 mm. Acquisition of T2-weighted and T1-weighted were performed. Interactive Data Language software was used to analyze the data.ResultsThe results of this study showed that: the overall accuracy of classification process was 94.8%, and for the tumor; the sensitivity was 97.3%. White matter and grey matter showed a classification accuracy of 95.7% and 89.7% and for CSF the accuracy was 94.3%.ConclusionThe results showed that brain tumor can be classified successfully and delineated using texture analysis with minimum efforts and with high accuracy for brain tumors.  相似文献   

4.
BackgroundThe objective of this study was to propose an optimal input image quality for a conditional generative adversarial network (GAN) in T1-weighted and T2-weighted magnetic resonance imaging (MRI) images.Materials and methodsA total of 2,024 images scanned from 2017 to 2018 in 104 patients were used. The prediction framework of T1-weighted to T2-weighted MRI images and T2-weighted to T1-weighted MRI images were created with GAN. Two image sizes (512 × 512 and 256 × 256) and two grayscale level conversion method (simple and adaptive) were used for the input images. The images were converted from 16-bit to 8-bit by dividing with 256 levels in a simple conversion method. For the adaptive conversion method, the unused levels were eliminated in 16-bit images, which were converted to 8-bit images by dividing with the value obtained after dividing the maximum pixel value with 256.ResultsThe relative mean absolute error (rMAE ) was 0.15 for T1-weighted to T2-weighted MRI images and 0.17 for T2-weighted to T1-weighted MRI images with an adaptive conversion method, which was the smallest. Moreover, the adaptive conversion method has a smallest mean square error (rMSE) and root mean square error (rRMSE), and the largest peak signal-to-noise ratio (PSNR) and mutual information (MI). The computation time depended on the image size.ConclusionsInput resolution and image size affect the accuracy of prediction. The proposed model and approach of prediction framework can help improve the versatility and quality of multi-contrast MRI tests without the need for prolonged examinations.  相似文献   

5.
Longitudinal MRI was applied to monitor intracranial initiation and development of brain metastases and assess tumor vascular volume and permeability in a mouse model of breast cancer brain metastases. Using a 9.4T system, high resolution anatomic MRI and dynamic susceptibility contrast (DSC) perfusion MRI were acquired at different time points after an intracardiac injection of brain-tropic breast cancer MDA-MB231BR-EGFP cells. Three weeks post injection, multifocal brain metastases were first observed with hyperintensity on T2-weighted images, but isointensity on T1-weighted post contrast images, indicating that blood-tumor-barrier (BTB) at early stage of brain metastases was impermeable. Follow-up MRI revealed intracranial tumor growth and increased number of metastases that distributed throughout the whole brain. At the last scan on week 5, T1-weighted post contrast images detected BTB disruption in 160 (34%) of a total of 464 brain metastases. Enhancement in some of the metastases was only seen in partial regions of the tumor, suggesting intratumoral heterogeneity of BTB disruption. DSC MRI measurements of relative cerebral blood volume (rCBV) showed that rCBV of brain metastases was significantly lower (mean  = 0.89±0.03) than that of contralateral normal brain (mean  = 1.00±0.03; p<0.005). Intriguingly, longitudinal measurements revealed that rCBV of individual metastases at early stage was similar to, but became significantly lower than that of contralateral normal brain with tumor growth (p<0.05). The rCBV data were concordant with histological analysis of microvascular density (MVD). Moreover, comprehensive analysis suggested no significant correlation among tumor size, rCBV and BTB permeability. In conclusion, longitudinal MRI provides non-invasive in vivo assessments of spatial and temporal development of brain metastases and their vascular volume and permeability. The characteristic rCBV of brain metastases may have a diagnostic value.  相似文献   

6.
The sustenance of most solid tumors including head and neck cancers (HNCs) is strongly dependent on the presence of a functioning vascular network. In this study, we examined the acute effects of a tumor vascular disrupting agent (VDA), 5,6-dimethylxanthenone-4-acetic acid (DMXAA; ASA404), in an orthotopic model of human HNC. Noninvasive magnetic resonance imaging (MRI) was used to monitor the vascular response of orthotopic FaDu xenografts to VDA therapy. Untreated tumors showed a marked but heterogeneous pattern of enhancement after contrast agent injection on serial T1-weighted (T1W) MR images. After VDA treatment, T2W and T1W MRI revealed evidence of hemorrhaging and lack of functioning vessels (enhancement) within the tumor. Quantitative estimates of relative vascular volume also showed a significant (P < .01) reduction in DMXAA-treated tumors 24 hours after therapy compared with untreated controls. Histology and immunostaining of untreated orthotopic FaDu tumors revealed poorly differentiated squamous cell carcinoma histology with distinctly visible CD31+ endothelial cells. In sharp contrast, minimal CD31 staining with irregular endothelial fragments and faint outlines of blood vessels were seen in DMXAA-treated tumor sections. CD31 immunostaining and histology also highlighted the selectivity of vascular damage and tissue necrosis after VDA therapy with no evidence of toxicity observed in normal salivary gland, heart, liver, and skeletal muscle tissues. Together, our results demonstrate a potent and selective vascular disruptive activity of DMXAA in an orthotopic HNC model. Further evaluation into its antitumor effects alone and in combination with other agents is warranted.  相似文献   

7.

Purpose

The purpose of this study was to estimate the value of addition of liver imaging to initial rectal magnetic resonance imaging (MRI) for detection of liver metastasis and evaluate imaging predictors of a high risk of liver metastasis on rectal MRI.

Methods

We enrolled 144 patients who from October 2010 to May 2013 underwent rectal MRI with T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) (b values = 50, 500, and 900 s/mm2) of the liver and abdominopelvic computed tomography (APCT) for the initial staging of rectal cancer. Two reviewers scored the possibility of liver metastasis on different sets of liver images (T2WI, DWI, and combined T2WI and DWI) and APCT and reached a conclusion by consensus for different analytic results. Imaging features from rectal MRI were also analyzed. The diagnostic performances of CT and an additional liver scan to detect liver metastasis were compared. Multivariate logistic regression to determine independent predictors of liver metastasis among rectal MRI features and tumor markers was performed. This retrospective study was approved by the Institutional Review Board, and the requirement for informed consent was waived.

Results

All sets of liver images were more effective than APCT for detecting liver metastasis, and DWI was the most effective. Perivascular stranding and anal sphincter invasion were statistically significant for liver metastasis (p = 0.0077 and p = 0.0471), while extramural vascular invasion based on MRI (mrEMVI) was marginally significant (p = 0.0534).

Conclusion

The addition of non-contrast-enhanced liver imaging, particularly DWI, to initial rectal MRI in rectal cancer patients could facilitate detection of liver metastasis without APCT. Perivascular stranding, anal sphincter invasion, and mrEMVI detected on rectal MRI were important imaging predictors of liver metastasis.  相似文献   

8.
We have examined a hexafluorinated 2-nitroimidazole, CCI-103F, as a probe for hypoxic tumor cells by in vivo 19F magnetic resonance spectroscopy (MRS). Following initial intraperitoneal injections of the drug in tumor-bearing (Dunning R3327-AT1-Matlylu) rats, 19F spectra were obtained on an Otsuka 2.0T Vivospec spectrometer using a 1.5-cm surface coil. Signal at 1- and 2-h time points indicated initial biodistribution of drug in the tumor. At 4 and 8 h, a progressive increase in signal intensity was observed, indicating retention of drug within the tumor. Tumor signal remained detectable in 4 of 10 rats at 24 h, indicating possible nitroreductive bioactivation by hypoxic cells. Immunohistochemistry of these tumors revealed a staining pattern consistent with labeling of hypoxic cells. No detectable 19F signal was found at 24 h for the other rats, indicating complete washout of unbound drug. Immunohistochemical assessment of these tumors revealed some staining for bound drug at the periphery of necrotic zones. 31P-MRS of the tumors showed good correlation with the presence or absence of hypoxia as evaluated by 19F-MRS, T1- and T2-weighted images, and immunohistochemistry. These results provide the groundwork for further studies using this misonidazole analog for noninvasive identification of hypoxic tumor cells in vivo by MRS.  相似文献   

9.
The aim of our study is to characterize the venous vasculatures of hepatocellular carcinoma (HCC) using a multi-breath-hold two-dimensional (2D) susceptibility weighted imaging (SWI) in comparison with conventional Magnetic Resonance Imaging (MRI) sequences. Twenty-nine patients with pathologically confirmed HCC underwent MR examination at a 3.0 T scanner. The number of venous vascularity in or around the lesion was counted and the image quality was subjectively evaluated by two experienced radiologists independently based on four image sets: 1) SWI, 2) T1-weighted sequence, 3) T2-weighted sequence, and 4) T1-weighted dynamic contrast-enhanced (DCE) sequence. Of the 29 patients, a total of 33 liver lesions were detected by both SWI and conventional MR sequences. In the evaluation of the conspicuity of venous vascularity, a mean of 10.7 tumor venous vessels per mass was detected by the SWI and 3.9 tumor vasculatures were detected by T1-weighted DCE (P<0.0001), while none was detected by T1-, T2-weighted sequences. The Pearson correlation coefficients between the lesion sizes and the number of tumor vasculatures detected by T1-weighted DCE was 0.708 (P<0.001), and 0.883 by SWI (P<0.001). Our data suggest that SWI appears to be a more sensitive tool compared to T1-weighted DCE sequence to characterize venous vasculature in liver lesions.  相似文献   

10.
Vertebral hemangiomas are an incidental and relatively common radiological finding and a benign tumor of vascular origin. VH are the most common spine tumors with an estimated incidence of 1.9-27% in the general population. Rarely, vertebral hemangiomas can exhibit extraosseous expansion with resulting compression of the spinal cord. Such lesions are termed aggressive or atypical vertebral hemangiomas (AVH) and account for less than 1% of spinal hemangiomas. A 68-year-old female was referred with progressive walking difficulty and sensory disturbances in her lower extremities. MRI imaging of the thoracic spine revealed a T1- and T2-weighted hyperintense lesion involving the T10 vertebra. Additionally, there was extraosseous extension of the tumor into the spinal canal, located both anterior and posterior to the spinal cord, causing severe spinal cord compression. A combined endovascular and surgical approach (arterial coil embolization and en bloc resection) for treatment was decided. Although vertebral hemangiomas are an incidental and relatively common radiological finding, the findings of our case were consistent with an aggressive hemangioma with atypical MRI and clinical prognostic characteristics. In summary, the present case highlights the need for multidisciplinary approach and in-depth knowledge of this rare pathologic entity.  相似文献   

11.
RATIONALE AND OBJECTIVES: To evaluate the imaging capabilities of ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) in monitoring interstitial cryotherapy and to compare them with visual control. METHODS: An experimental MR-compatible, vacuum-insulated and liquid nitrogen-cooled cryoprobe was inserted under in vitro conditions into a porcine liver, which was kept at a temperature of 37 +/- 1 degrees C, in a water bath with continuous stirring. The freezing procedure was controlled macroscopically, by US (Toshiba Sonolayer, 7.5-MHz linear array transducer), by CT (Siemens Somatom Plus, slice thickness 2-8 mm, 165-210 mA at 120 kV), and by MRI (Philips Gyroscan ACS-NT, FFE TR/TE/FA = 15/5.4/25 degrees, T1-SE 550/20, T2-TSE 1800/100) after the iceball reached its maximum size. RESULTS: The maximum iceball diameter around the probe tip was 12.0 mm by visual control, 12.4 mm by US, 12.7 mm by CT, and within 12.8 mm by spin echo sequences and 11 mm by gradient echo sequence. Due to the nearly signal-free appearance of the frozen tissue on MR images, the ice/tissue contrast on T1-weighted and gradient echo images was superior to T2-weighted images and CT images. Sonographically, the ice formation appeared as a hyperechoic sickle with nearly complete acoustic shadowing. CONCLUSION: Due to the better ice/tissue contrast, T1-weighted or gradient echo MR images were superior to CT and US in monitoring interstitial cryotherapy. Gradient echo sequences generally underestimated the ice diameter by 15%.  相似文献   

12.
Automatic classification of tissue types of region of interest (ROI) plays an important role in computer-aided diagnosis. In the current study, we focus on the classification of three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor) in T1-weighted contrast-enhanced MRI (CE-MRI) images. Spatial pyramid matching (SPM), which splits the image into increasingly fine rectangular subregions and computes histograms of local features from each subregion, exhibits excellent results for natural scene classification. However, this approach is not applicable for brain tumors, because of the great variations in tumor shape and size. In this paper, we propose a method to enhance the classification performance. First, the augmented tumor region via image dilation is used as the ROI instead of the original tumor region because tumor surrounding tissues can also offer important clues for tumor types. Second, the augmented tumor region is split into increasingly fine ring-form subregions. We evaluate the efficacy of the proposed method on a large dataset with three feature extraction methods, namely, intensity histogram, gray level co-occurrence matrix (GLCM), and bag-of-words (BoW) model. Compared with using tumor region as ROI, using augmented tumor region as ROI improves the accuracies to 82.31% from 71.39%, 84.75% from 78.18%, and 88.19% from 83.54% for intensity histogram, GLCM, and BoW model, respectively. In addition to region augmentation, ring-form partition can further improve the accuracies up to 87.54%, 89.72%, and 91.28%. These experimental results demonstrate that the proposed method is feasible and effective for the classification of brain tumors in T1-weighted CE-MRI.  相似文献   

13.
Microcystin-LR (MCLR)-induced hepatotoxicity was assessed in vivo in male Sprague-Dawley rats (150-350 g) using magnetic resonance imaging (MRI). Following the intraperitoneal administration of MCLR (LD(50)), a region of damage, characterised by increased signal intensity on T(2)-weighted images, was seen proximal to the hepatic portal vein in the liver. Similarly, increased signal intensity was seen in the chemical-shift selective images (CSSI) of water frequency, proximal to the hepatic portal vein in the liver. This indicates that the increased signal intensity observed in the T(2)-weighted images was due to an increased amount of magnetic resonance (MR) visible protons in the tissue which represents an oedematous response. Image analysis of regions of apparent damage around the hepatic portal vein indicated a statistically significant increase in signal intensity in this region. Mitochondrial swelling and lipid inclusions were observed by transmission electron microscopy (TEM) in samples obtained from the oedematous regions of the liver using spatial coordinates from the magnetic resonance (MR) images. Massive haemorrhagic necrosis and nuclear swelling were observed by light microscopy in the centrilobular regions of the lobules.  相似文献   

14.
Current radiographic response criteria for brain tumors have difficulty describing changes surrounding postoperative resection cavities. Volumetric techniques may offer improved assessment, however usually are time-consuming, subjective and require expert opinion and specialized magnetic resonance imaging (MRI) sequences. We describe the application of a novel volumetric software algorithm that is nearly fully automated and uses standard T1 pre- and post-contrast MRI sequences. T1-weighted pre- and post-contrast images are automatically fused and normalized. The tumor region of interest is grossly outlined by the user. An atlas of the nasal mucosa is automatically detected and used to normalize levels of enhancement. The volume of enhancing tumor is then automatically calculated. We tested the ability of our method to calculate enhancing tumor volume with resection cavity collapse and when the enhancing tumor is obscured by subacute blood in a resection cavity. To determine variability in results, we compared narrowly-defined tumor regions with tumor regions that include adjacent meningeal enhancement and also compared different contrast enhancement threshold levels used for the automatic calculation of enhancing tumor volume. Our method quantified enhancing tumor volume despite resection cavity collapse. It detected tumor volume increase in the midst of blood products that incorrectly caused decreased measurements by other techniques. Similar trends in volume changes across scans were seen with inclusion or exclusion of meningeal enhancement and despite different automated thresholds for tissue enhancement. Our approach appears to overcome many of the challenges with response assessment of enhancing brain tumors and warrants further examination and validation.  相似文献   

15.
Although magnetic resonance imaging (MRI) is a useful technique, only a few studies have investigated the dynamic behavior of small subjects using MRI owing to constraints such as experimental space and signal amount. In this study, to acquire high-resolution continuous three-dimensional gravitropism data of pea (Pisum sativum) sprouts, we developed a small-bore MRI signal receiver coil that can be used in a clinical MRI and adjusted the imaging sequence. It was expected that such an arrangement would improve signal sensitivity and improve the signal-to-noise ratio (SNR) of the acquired image. All MRI experiments were performed using a 3.0-T clinical MRI scanner. An SNR comparison using an agarose gel phantom to confirm the improved performance of the small-bore receiver coil and an imaging experiment of pea sprouts exhibiting gravitropism were performed. The SNRs of the images acquired with a standard 32-channel head coil and the new small-bore receiver coil were 5.23±0.90 and 57.75±12.53, respectively. The SNR of the images recorded using the new coil was approximately 11-fold higher than that of the standard coil. In addition, when the accuracy of MR imaging that captures the movement of pea sprout was verified, the difference in position information from the optical image was found to be small and could be used for measurements. These results of this study enable the application of a clinical MRI system for dynamic plant MRI. We believe that this study is a significant first step in the development of plant MRI technique.  相似文献   

16.
Darrasse L  Ginefri JC 《Biochimie》2003,85(9):915-937
Since discovery of high-temperature superconductive (HTS) ceramics by Bednorz and Muller in 1986, there has been an accelerated development of cold technologies in industry, including the domain of NMR detection. The purpose of this paper is to fix ideas about the stage that cryogenic radio frequency (RF) probe techniques have reached in biomedical magnetic resonance imaging (MRI). Readers confronted to the literature about this emerging topic have to understand a large range of motivations with somewhat unclearly defined technical limitations and actual outlets. An overview of sensitivity issues in the general context of biomedical MRI is provided here and the contribution of RF coil techniques to recent advances is identified. The domains where cooled coil materials such as copper, low- or high-temperature superconductors, could actually increase the RF coil sensitivity are delimited by a quantitative analysis of noise mechanisms. Technical keys, cryogenic means and cold RF coil technologies are considered, and first achievements in different fields of biomedical MRI are reviewed. This survey provides a basis for discussing about the future impact of cryogenic probes for MRI investigations.  相似文献   

17.

Background

This article explains some simple experiments that can be used in undergraduate or graduate physics or biomedical engineering laboratory classes to learn how birdcage volume radiofrequency (RF) coils and magnetic resonance imaging (MRI) work. For a clear picture, and to do any quantitative MRI analysis, acquiring images with a high signal-to-noise ratio (SNR) is required. With a given MRI system at a given field strength, the only means to change the SNR using hardware is to change the RF coil used to collect the image. RF coils can be designed in many different ways including birdcage volume RF coil designs. The choice of RF coil to give the best SNR for any MRI study is based on the sample being imaged.

Results

The data collected in the simple experiments show that the SNR varies as inverse diameter for the birdcage volume RF coils used in these experiments. The experiments were easily performed by a high school student, an undergraduate student, and a graduate student, in less than 3 h, the time typically allotted for a university laboratory course.

Conclusions

The article describes experiments that students in undergraduate or graduate laboratories can perform to observe how birdcage volume RF coils influence MRI measurements. It is designed for students interested in pursuing careers in the imaging field.
  相似文献   

18.

Purpose

To evaluate whether gadoxetic acid (Gd-EOB-DTPA)-enhanced MR images of tumors taken during the hepatocyte-specific phase can aid in the differentiation between hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) in patients with atypical cirrhotic nodules detected on dynamic CT images.

Materials and Methods

Seventy-one patients with 112 nodules showing atypical dynamic enhancement on CT images underwent gadoxetic acid-enhanced MR imaging (MRI) studies. Using a reference standard, we determined that 33 of the nodules were DNs and that 79 were true HCCs. Tumor size, signal intensity on precontrast T1-weighted images (T1WI) and T2WI, and the pattern of dynamic enhancement on MR images taken in the hepatocyte-phase were determined.

Results

There were significant differences in tumor size, hyperintensity on T2WI, hypointensity on T1WI, typical HCC enhancement pattern on dynamic MR images, or hypointensity on hepatocyte-phase images between DNs and HCC. The sensitivity and specificity were 60.8% and 87.9% for T2WI, 38.0% and 87.9% for T1WI, 17.7% and 100% for dynamic MR imaging, 83.5% and 84.9% for hepatocyte-phase imaging, and 60.8% and 87.9% for tumor size (threshold of 1.7 cm).

Conclusion

Gd-EOB-DTPA-enhanced hepatocyte-phase imaging is recommended for patients at high risk of HCC who present with atypical lesions on dynamic CT images.  相似文献   

19.
Cranial MRI of small rodents using a clinical MR scanner   总被引:1,自引:0,他引:1  
Increasing numbers of small animal models are in use in the field of neuroscience research. Magnetic resonance imaging (MRI) provides an excellent method for non-invasive imaging of the brain. Using three-dimensional (3D) MR sequences allows lesion volumetry, e.g. for the quantification of tumor size. Specialized small-bore animal MRI scanners are available for high-resolution MRI of small rodents' brain, but major drawbacks of this dedicated equipment are its high costs and thus its limited availability. Therefore, more and more research groups use clinical MR scanners for imaging small animal models. But to achieve a reasonable spatial resolution at an acceptable signal-to-noise ratio with these scanners, some requirements concerning sequence parameters have to be matched. Thus, the aim of this paper was to present in detail a method how to perform MRI of small rodents brain using a standard clinical 1.5 T scanner and clinically available radio frequency coils to keep material costs low and to circumvent the development of custom-made coils.  相似文献   

20.
The aim of this study was to successfully establish an orthotopic murine model using two different human pancreatic adenocarcinoma cell lines and to propose a 3.0 tesla MRI protocol for noninvasive characterization of this model. SW1990 and MIAPaca-2 tumor cells were injected into the pancreas of BALB/C nu/nu mice. Tumor growth rate and morphological information were assessed by 3.0 tesla MRI (T1WI, T2WI and DCE-MRI) and immunohistology. Proliferation of SW1990 was significantly faster than that of MIAPaca-2 (P=0.000), but MIAPaca-2 mice had a significantly shorter survival than SW1990 mice (41 days and 44 days respectively, P=0.027). MRI could reliably monitor tumor growth in both cell lines: the tumors exhibiting a spherical growth pattern showed a high-intensity signal, and the SW1990 group developed significantly larger tumors compared with the MIAPaCa-2 group. There were no statistical differences between the two groups in which tumor size was assessed using electronic calipers and an MRI scan (P=0.680). Both tumors showed a slow gradual enhancement pattern. Immunohistochemistry demonstrated tumor tissues showing high expression of Ki-67. This model closely mimics human pancreatic cancer and permits monitoring of tumor growth and morphological information by noninvasive 3.0 tesla MRI studies reducing the number of mice required.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号