首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A solid-phase extraction (SPE) method for sample clean-up followed by a reversed-phase HPLC procedure for the assay of alinastina (pINN) in biological fluids is reported. The effects of the sample pH, composition of the washing and elution solvents and the nature of the SPE cartridge on recovery were evaluated. The selectivity of SPE was examined using spiked rat urine and plasma samples and the CH and PH cartridges gave rise to the cleanest extracts. The recoveries obtained in spiked rat urine and plasma samples were 91.2±2.7 and 99.9±2.8%, respectively. The proposed SPE method coupled off-line with a reserved-phase HPLC system with fluorimetric detection was applied to the quantitation of alinastine in real rat urine samples. The analytical method was also applied and validated for the determination of alinastine in dog plasma. The recovery from spiked dog plasma samples using the PH cartridge was around 65%. The within-day and between-day precisions were 7 and 12%, respectively. The detection and quantitation limits in dog plasma were 0.024 and 0.078 μg/ml, respectively.  相似文献   

2.
A HPLC method was validated for quantification of (+)-calanolide A (1), a novel anti-HIV agent, in rat, dog and human plasma. The synthetic intermediate (±)-12-oxocalanolide A (2) was found to be a suitable internal standard. Compounds were extracted from plasma using a solid-phase C18 cartridge and quantified over the assay range of 12.5 to 800 ng/ml. The method was utilized to determine (+)-calanolide A pharmacokinetics in rats, dogs and humans. This is the first report of a validated HPLC assay for determination of (+)-calanolide A concentrations in rat and dog plasma as well as human plasma obtained from clinical trials. There was no evidence of in vivo epimerization of (+)-calanolide A to its inactive epimer (+)-calanolide B (3).  相似文献   

3.
A simple and precise high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of a novel angiotensin II antagonist, 1-[5-(2-cyclopropyl-5,7-dimethyl-imidazo[4,5-b]pyridin-3-ylmethyl)thiopen-2-yl)cyclopent-3-enecarboxylic acid (CP-191,166, I), in dog and rat plasma. The internal standard (II, a saturated derivative of I) and analyte were extracted by liquid-liquid extraction using methyl tert.-butyl ether. Samples were analyzed by reversed-phase HPLC using a Zorbax C8 narrow-bore column with ultraviolet detection at 289 nm. The quantitation limit of I was 10 ng/ml and the calibration curve was linear over the range of 0.01–10.0 μg/ml (r2>0.99). In dog and rat plasma, intra- and inter-assay precision ranged from 0.00 to 3.36% and 0.00 to 4.95%, respectively. The average recoveries were similar (73%) for both I and II and the upper limit of quantification of I can be as high as 500 μg/ml. The method described has been successfully applied to the quantification of I in about 2000 dog and rat plasma samples over a nine-month period.  相似文献   

4.
An HPLC assay for plasma analysis of LY303366 (I), a semi-synthetic lipopeptide antifungal related to echinocandin B (ECB), was developed to support the selection and subsequent preclinical development of I. The method involved extraction of I from plasma with the aid of solid-phase extraction (SPE) cartidges followed by reversed-phase HPLC with UV detection at 300 nm. The method is simple, selective and is applicable to dog, rat, mouse and rabbit plasma. Validation studies using dog plasma showed that the values obtained for parameters of linearity, precision and accuracy were within acceptable limits. Based on analysis of 0.3 ml of plasma, the lower limit of quantitation was 20 ng/ml. The method has been successfully applied to determine the pharmacokinetic parameters of I in the dog following intravenous (i.v.) and oral administration. Compared to first generation ECB antifungal agents, the results of the i.v. dog study indicated a 50% reduction in clearance of the drug from plasma (0.1 l/h/kg) and an 18-fold increase in the volume of distribution at steady state (1.8 l/kg). When administered orally, compound I had an absolute bioavailability of 9%; however, plasma levels remained above the MIC for C. albicans (0.005 μg/ml) through 48 h. Given the excellent potency of I and its broad spectrum of activity relative to first generation ECB antifungal agents, the assay results for I indicate the potential for its use as a broad spectrum i.v. and oral antifungal agent.  相似文献   

5.
Reversed-phase HPLC procedures were developed for the determination of tolcapone (Ro 40-7592) and its metabolites Ro 40-7591, Ro 61-1448, and Ro 47-1669 in plasma and in urine samples. One of the procedures for plasma involved the determination of tolcapone and its metabolite Ro 40-7591 and the other, the determination of the two other metabolites. The urine assay enabled the simultaneous determination of tolcapone and all metabolites in one run. Sample preparation in plasma involved protein precipitation with acetonitrile. Urine was simply diluted. The compounds of interest were monitored in the UV at 270 nm. The limits of quantification were 0.05 μg/ml for each compound (plasma assay) and 0.2 μg/ml for the urine assay. The mean inter-assay precisions (C.V.) were ≤6% (plasma assay) and ≤8% (urine assay). The procedures were successfully applied to the sample analysis of animal pharmacokinetic (rat, dog, mouse, rabbit and cynomolgus monkey) and clinical pharmacology studies.  相似文献   

6.
An HPLC assay for DMP 811, 4-ethyl-2-propyl-1-[(2′-(1H-tetrazol-5-yl)biphenyl-4-yl)-methyl]imidazole-5-carboxylic acid (I) in rat and dog plasma has been developed. Compound I was isolated from plasma using a liquid—liquid back extraction procedure. The extraction recovery was greater than 81%. Separation of I from endogenous components in plasma was achieved on an E. Merck C8 column using a mobile phase of 0.05 M ammonium acetate, brought to pH 3.75 with acetic acid, and acetonitrile (78:22, v/v). The eluent was monitored by fluorescence with excitation and emission set at 235 and 370 nm, respectively. The assay was linear from 2 to 2000 ng/ml. Inter- and intra-day coefficients of variation for the rat-plasma assay ranged from 0.9 to 5.2% (5–2000 ng/ml) and 2.7 to 16.5% (2–2000 ng/ml), respectively. The respective coefficients of variation for the dog-plasma assay were 1.9 to 5.6% and 1.2 to 14.0%. The percent differences from the accuracy results were 12% or less. Using 0.5 ml of plasma for extraction, the minimum quantifiable limit was 2 ng/ml. This method has been used to quantify plasma levels of I in rats or dogs following 3–10 mg/kg i.v. or p.o. doses.  相似文献   

7.
A method for the analysis of the AMPA (α-amino-3-hydroxy-5-methyl-4-isoxazolepropionate) receptor antagonist LY300164 (compound I) and its N-acetyl metabolite (compound II) in plasma was developed. The assay utilized solid-phase extraction on a C18 Bond Elut cartridge followed by reversed-phase HPLC with UV detection at 310 nm. The method exhibited a large linear range from 0.05 μg/ml to 50 μg/ml with an intra-sassay accuracy for compound I and compound II ranging from 89.0% to 114.5% and intra-assay precision ranging from 0.5 to 15.3% in mouse, rat, dog, and monkey plasma. The inter-assay accuracy of compound I and compound II was 93.3% to 101.8% and the inter-assay precision was 1.6% to 11.2% in dog plasma. The lower limit of quantitation was 0.05 μg/ml for compound I in plasma from all species tested. The lower limit of quantitation for compound II was 0.05 μg/ml in dog and monkey plasma and 0.1 μg/ml in mouse and rat plasma. Extracts of compound I and II from dog plasma were shown to be stable for 24 h at room temperature, and both compounds were stable when spiked into rat and monkey plasma frozen at −70°C for 27 days. The method has shown to be useful in the investigation of the pharmacokinetics of the parent compound (I) and metabolite (II) in preclinical studies.  相似文献   

8.
An enantioselective high-performance liquid chromatographic method for the determination of E3810, a new anti-ulcer agent, in Beagle dog plasma and rat plasma has been developed. After extraction from plasma with ethyl acetate. E3810 enantiomer were measured by reversed-phase high-performance liquid chromatography on a Chiralcel OD-R column. The enantiomers were detected by ultraviolet absorbance detection at 290 nm. The recoveries of E3810 enantiomers and internal standard were greater than 91%. The calibration curves were linear from 0.03 to 20 μg/ml for Beagle dog plasma and from 0.1 to 100 μg/ml for rat plasma. The limits of quantification of both enantiomers were 0.03 μg/ml for Beagle dog plasma and 0.1 μg/ml for rat plasma. The intra- and inter-day accuracy and precision data showed good reproducibility of the method. The assay was applied for the analysis of E3810 enantiomers in plasma after intravenous administration of racemic E3810 to Beagle dogs and rats. This method should be very useful for enantioselective pharmacokinetic studies of E3810.  相似文献   

9.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of the antiallergenic compound N-[4-(1H-imidazol-1-yl)butyl]-2-(1-methylethyl)-11-oxo-11H-pyrido[2,1-b] quinazoline-8-carboxamide (I), and its major metabolite, 2-(1-methylethyl)-11-oxo-11H-pyrido[2,1-b] quinazoline-8-carboxylic acid (I-A), in plasma. The assay involves precipitation of the plasma proteins with aceto-nitrile—methanol (9:1), followed by the analysis of an aliquot of the protein-free filtrate by reversed-phase ion-pair HPLC with fluorescence detection for quantitation. The analogous compound, N-[6-(1H-imidazol-1-yl)hexyl]-2-(1-methylethyl)-11-oxo-11H-pyrido[2,1-b]-quinazoline-8-carbonxamide (II), is used as the internal standard. The overall recovery of compounds I and I-A from plasma is 107.0 ± 8.6% and 107.0 ± 10.0%, respectively. The sensitivity limits of quantitation are 20 ng of I, and 10 ng of I-A per ml of plasma using a 0.5-ml aliquot. The assay was used to monitor the plasma concentrations of I and of I-A in a dog following a 5 mg/kg intravenous infusion of I · 2HCl, a 10mg/kg oral dose of I · 2HCl and of metabolite I-A.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) procedure has been developed for the quantification of L-365,260 (I), a cholecystokinin and gastrin receptor antagonist, in dog and rat plasma. The method involves liquid—liquid extraction and HPLC with ultraviolet detection. Standard curves were linear over the range 7.5–2000 ng/ml for rat and dog plasma. The method is reproducible and reliable with a detection limit of 7.5 ng/ml in biological fluids. The mean coefficients of variation for concentrations within the range of the standard curve range were 3.84 and 2.56%, respectively, for intra-day analysis and 4.48 and 4.26%, respectively, for inter-day analysis. Application of the development was successfully demonstrated by quantifying the concentration of I in both dog and rat plasma samples following an intravenous or oral dose of 5 mg/kg I.  相似文献   

11.
A specific and sensitive liquid chromatographic assay for the determination of 4-amidino-1-indanone-2′-amidinohydrazone (CGP 48 664, I) and a potential metabolite, 2-(4-carbamoyl-2,3-dihydro-1H-inden-1-yliden) hydrazine carboximidamide (CGP 53 391, II), in human and animal plasma was developed. CGP 51 467, a structural analog, was added to the plasma samples (up to 1 ml) as an internal standard. After mixing, the samples were processed automatically using an ASPEC solid-phase extraction system. The final extracts were chromatographed on a 5 μm Purospher RP-18 HPLC column. Chromatography was performed using a gradient system and UV detection. The described HPLC method is suitable for specific and quantitative measurement of concentrations of I, as well as its potential metabolite II down to 5–10 ng/ml in human and animal (dog, rat) plasma with acceptable reproducibility and accuracy.  相似文献   

12.
To support toxicokinetic assessments, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of BMS-790052 in rat, dog, monkey, rabbit and mouse K(2)EDTA plasma. The drug was isolated from buffered samples using ISOLUTE C8 96-well solid phase extraction (SPE) plates. Chromatographic separation was achieved on a Waters Atlantis dC18 analytical column (2.1 mm × 50 mm, 5 μm) with detection accomplished using an API 4000 tandem mass spectrometer in positive ion electrospray and multiple reaction monitoring (MRM) mode. The standard curves, which ranged from 5.00 to 2000 ng/mL for BMS-790052, were fitted to a 1/x(2) weighted linear regression model. The intra-assay precision (%CV) and inter-assay precision (%CV) were within 8.5%, and the assay accuracy (%Dev) was within ±7.1 for rat, dog, monkey, rabbit and mouse K(2)EDTA plasma. This accurate, precise, and selective SPE/LC-MS/MS method has been successfully applied to analyze several thousands of non-clinical study samples.  相似文献   

13.
The neuromedin U-like immunoreactivity in an extract of dog small intestine was resolved by reversed-phase HPLC into two molecular forms. The primary structure of the larger form (NMU-25) was established as: Phe-Arg-Leu-Asp-Glu-Glu-Phe-Gln-Gly-Pro10-Ile-Ala-Ser-Gln-Val-Arg- Arg-Gln-Phe- Leu20-Phe-Arg-Pro-Arg-Asn-NH2. This sequence shows five substitutions relative to pig neuromedin U-25. The primary structure of the second peptide (NMU-8) was established as: pGlu-Phe-Leu-Phe-Arg-Pro-Arg-Asn-NH2. The sequence contains the substitution pGlu for Tyr1 compared with pig neuromedin U-8. The potency of synthetic dog NMU-8 in contracting smooth muscle from the rat uterus (EC50 10 +/- 2 nM; mean +/- S.E., n = 6) was not significantly different from the corresponding potency of pig NMU-8 (EC50 16 +/- 5 nM) but the maximum response produced by the dog peptide was greater (58%; p less than 0.05) than that produced by pig NMU-8.  相似文献   

14.
槲皮素体内外抗氧化作用的比较研究   总被引:6,自引:0,他引:6  
目的 :测定槲皮素的体外总抗氧化力 ,进一步观察槲皮素灌胃后大鼠外周血总抗氧化力的变化 ,并与芦丁、维生素C、维生素E相比较。方法 :总抗氧化力采用Fe3 还原法 ,槲皮素、芦丁分析采用紫外分光光度法及高效液相色谱法。结果 :相同浓度条件下槲皮素的体外总抗氧化力显著强于芦丁 ,与传统的抗氧化剂维生素C、维生素E相当。槲皮素 4 0mg/kg灌胃 1h后大鼠外周血总抗氧化力及槲皮素含量 (紫外分光光度法 )较灌胃前升高最为明显。维生素C也有显著提高外周血总抗氧化力的作用 ,芦丁与维生素E未表现出显著作用。血浆高效液相分析表明槲皮素灌胃后未出现明显的槲皮素吸收峰 ,而与其峰相邻的两个未知峰的面积增大。结论 :槲皮素的体外抗氧化作用强于芦丁 ,与传统的抗氧化剂维生素C、维生素E相当 ;槲皮素吸收后经代谢形成衍生物 ,提高血浆总抗氧化力的程度与维生素C相近  相似文献   

15.
A rapid, sensitive and specific normal-phase (adsorption) high-performance liquid chromatographic (HPLC) assay was developed for the determination of 1-(2-aminoethyl)-3-(2,6-dichlorophenyl)thiourea [I] in plasma and urine. The assay involves the extraction of the compound into methylene chloride from plasma or urine buffered to pH 10, and the HPLC analysis of the residue dissolved in methylene chloride—methanol—heptane (85:10:5). A 10-μm silica gel column was used with methylene chloride—methanol—heptane—ammonium hydroxide (85:10:5:0.1) as the eluting solvent. The effluent was monitored at 254 nm and quantitation was based on the peak height vs. concentration technique. The assay has a recovery of 64.5 ± 4.5% (S.D.) from plasma and 96.0 ± 6.3% (S.D.) from urine in the concentration range of 0.1–2 μg per ml and 2–40 μg per 0.1 ml of plasma and urine, respectively, with a limit of detection of 0.05–0.1 μg [I] per ml of plasma using a 1-ml specimen and 0.1 μg per ml urine using a 0.1-ml specimen, respectively. The assay was applied to the determination of plasma levels and urinary excretion of the compound [I] in dog following the oral administration of 28.8 mg of [I] · maleate per kg body weight.The HPLC assay was also used to determine the stability of [I] and for the measurement of a potential degradation product, clonidine [II] [2-(2,6-dichlorophenylamino)-2-imidazoline] in pooled human plasma stored at ?17°C, and pooled human urine stored at ?17°C and ?90°C, respectively.  相似文献   

16.
A rapid and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of the antiarrhythmic quinidine analog, 7′-trifluoromethyldihydrocinchonidine-2HCl ([I]-2HCl) in plasma and urine. The overall recovery of [I] from plasma was 86 ± 9% with a sensitivity limit of detection of 0.2 μg/ml.The assay involves extraction of [I] into benzene-methylene chloride (9:1) from plasma or urine made alkaline with 0.1 N sodium hydroxide (pH 13) and saturated sodium chloride, the residue of which is dissolved in methylene chloride, an aliquot of which is analyzed by HPLC using adsorption chromatography on silica gel with UV detection at 254 nm. The mobile phase composed of methylene chloride-methanol-conc. ammonium hydroxide (95.5:4:0.5) yields baseline resolution of quinidine used as the internal (reference) standard, compound [I] and dihydroquinidine, a common contaminant in quinidine.The assay was applied to the analysis of plasma and urine samples taken from a dog administered a single 20 mg/kg dose via intravenous and oral routes. The stability of [I] in human plasma for up to 37 days of storage at ?17°C was also demonstrated.  相似文献   

17.
S M Ho  P Ofner 《Steroids》1986,47(1):21-34
The goal of the present research was characterization of the interaction of 5 alpha-androstane-3 beta, 17 beta-diol (3 beta-diol) with prostatic estradiol-17 beta(E2) binding sites to address the role of this 5 alpha-dihydrotestosterone(DHT)a metabolite in prostatic regulation. Using dextran-charcoal assay we demonstrated specific 3 beta-diol and E2 binding sites in rat ventral prostate cytosol (RVPC) and dog prostate cytosol (DPC). In both cytosols, E2 binding is of high affinity (Ka congruent to 10(9) M-1; RVPC:68 fmol/mg protein), DPC:170 fmol/mg protein), and 3 beta-diol binding is of moderate affinity (Ka congruent to 10(8) M-1; RVPC:62 fmol/mg protein, DPC:165 fmol/mg protein). Unlabeled 3 beta-diol competes effectively for cytosolic 3H-E2 binding sites, whereas unlabeled DHT, 5 alpha-androstane-3 alpha, 17 beta-diol (3 alpha-diol) and testosterone (T) are poor competitors for 3H-E2 binding sites. Using DNA-cellulose column chromatography, we separated prostatic androgen and estrogen binding activities. The E2 binding activity which adhered to DNA-cellulose was displaced by 100-fold excess 3 beta-diol but not by DHT. Thus data from two assay procedures show competition of 3 beta-diol for 3H-E2 binding sites in rat and dog prostate.  相似文献   

18.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of 8-chloro-6-(2-chlorophenyl)-4H-imidazo-[1,5-a]-[1,4]-benzodiazepine-3-carboxamide [I] and its 4-hydroxy metabolite, 8-chloro-6-(2-chlorophenyl)-4-hydroxy-4H-imidazo-[1,5-a][1,4]-benzodiazepine-3-carboxamide [II] in whole blood, plasma or urine. The assay for both compounds involves extraction into diethyl ether—methylene chloride (70:30) from blood, plasma, or urine buffered to pH 9.0. The overall recoveries of [I] and [II] are 92.0 ± 5.4% (S.D.) and 90.3 ± 4.9% (S.D.), respectively. The sensitivity limit of detection is 50 ng/ml of blood, plasma, or urine using a UV detector at 254 nm. The HPLC assay was used to monitor the blood concentration—time fall-off profiles, and urinary excretion profiles in the dog following single 1 mg/kg intravenous and 5 mg/kg oral doses, and following multiple oral doses of 100 mg/kg/day of compound [I].  相似文献   

19.
The (Na+ + K+)-ATPase from dog kidney and partially purified membranes from HK dog erythrocytes were labeled with [3H]ouabain, solubilized with C12E8 and analyzed by HPLC through a TSK-GEL G3000SW column in the presence of C12E8, Mg2+, HPO4(2-) and glycerol at 20-23 degrees C. The peaks of [3H]ouabain bound to the enzyme from dog kidney and HK dog erythrocyte membranes corresponded to each other with apparent molecular weights of 470 000-490 000. In addition, these bindings of [3H]ouabain to the (Na+ + K+)-ATPase were observed to be stable at 20-23 degrees C for at least 18 h after the solubilization.  相似文献   

20.
An isocratic, reversed-phase high-performance liquid chromatographic procedure (HPLC) was developed for determination of the neuroprotective agent riluzole in mice plasma, brain and spinal cord. The procedure is based on isolation of the compound and the internal standard from plasma and central nervous system tissues using a Bakerbond spe C8 cartridge, with satisfactory recovery and specificity. Separation was on a C18 column, coupled with an UV detector at 263 nm. The assay was linear over a wide range, with a lower limit of quantification of 100 ng ml(-1) or g(-1) using 0.1 ml of plasma and about 100mg of brain tissue. The precision and accuracy were within the acceptable limits for an HPLC assay. The method is currently used to support pharmacological studies of the activity of riluzole when given in combination with other potential neuroprotective agents in an animal model of familiar amyotrophic lateral sclerosis (SOD1-G93A transgenic mice).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏