首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ninety-five fecal samples from Atlantic cod (Gadus morhua L.), caught along the northern Norwegian coast, were examined bacteriologically for occurrence of C. perfringens. Isolates were examined by polymerase chain reaction (PCR) for genes encoding the four lethal toxins (alpha, beta, epsilon, and iota) for classification into toxin types and for genes encoding enterotoxin and the novel beta2 toxin for further subclassification. In addition, a commercial enzyme-linked immunosorbent assay (ELISA) kit for detection of C. perfringens alpha, beta, and epsilon toxin was used. Clostridium perfringens could be isolated in 37 fecal samples (38.9%) from cod. All isolates were C. perfringens toxin type A (alpha toxin positive) as determined by PCR and also ELISA. In addition, in isolates from two cod (2.1%) the gene encoding for beta2 toxin was found (A, beta2) by PCR. Genes encoding for beta, epsilon, and iota toxins and enterotoxin were not found. This is the first detection of C. perfringens alpha and beta2 toxin in cod and of beta2 toxin in fish in general. The origin of this bacterium in cod is discussed.  相似文献   

2.
An enzyme-linked immunosorbent assay (ELISA) with antibodies specific to beta, epsilon and iota ib toxins of Clostridium perfringens was developed to detect beta, epsilon and iota ib toxins, respectively. The ELISA was sensitive enough to detect as little as 1.0 ng/ml of purified beta and iota ib toxins and 0.1 ng/ml of purified epsilon toxin. By means of the ELISA method, 192 isolates of C. perfringens from food samples in Japan and Thailand, and 58 isolates from patients suffering from gas gangrene or gastroenteritis were examined. One isolate from food samples in Japan, three from food samples in Thailand and five from stools of patients with gastroenteritis were C. perfringens type D. One type B and one type C were detected from the stools of patients with gastroenteritis.  相似文献   

3.
A simple, sensitive, and specific assay method for glycosyltransferase and glycosidase activities has been established by means of an enzyme-linked immunosorbent assay (ELISA) using monoclonal antibody, H-11 directed to lactoneotetraosylceramide (nLc4Cer). Enzyme activity was determined by assaying the amount of reaction product, nLc4Cer with the ELISA method. For the assay of galactosyltransferase activity, lactotriaosylceramide (Lc3Cer) immobilized on a 96-well microtiter plate was incubated with bovine milk galactosyltransferase in cacodylate buffer (pH 6.8) containing Triton CF-54, Mn2+, and UDP-galactose. Optimum incubation conditions for the enzyme were determined. Glycosidase activity was also assayed by the ELISA method by using Clostridium perfringens sialidase and neolacto-series gangliosides as substrates, and the substrate specificities towards the gangliosides were examined. By this method, 3-100 pmol of reaction product could be determined. The assay method has several advantages as follows: 1, the method is simple; 2, separation of the reaction product is not required; 3, quantification and identification of the reaction product were done simultaneously; 4, naturally occurring substrates are available (especially for glycosidase); 5, many samples can be assayed in one microplate; 6, sensitivity is very high. The present method was applied for the detection of galactosyltransferase in human sera. Significant elevations of the galactosyltransferase levels were observed in the sera from cancer patients. The formation of nLc4Cer was confirmed by employing the TLC-immunostaining method for bands of Lc3Cer after incubation of the bands with serum and cofactors on an HPTLC plate.  相似文献   

4.
In the USA, the potency of commercially prepared equine tetanus antitoxin is determined by the method outlined in the Code of Federal Regulations, Title 9, Part 113.451. In the current test, commercial equine tetanus antitoxin is tested by a toxin neutralization test in guinea pigs. The in vivo test measures antitoxin content through effectiveness of protection of guinea pigs injected with diluted mixtures of antitoxin and a standard toxin. A competitive enzyme-linked immunosorbent assay, designed as an in vitro alternative to the in vivo test, measures antitoxin content based on a competitive reaction between standard or unknown serum and murine monoclonal antibody specific for tetanus toxin. The monoclonal antibody used in the assay delayed death in mouse passive protection studies and reacted with the C fragment of tetanus toxin. No cross-reaction was observed when the antibody was tested with the toxins of Clostridium chauvoei, C. novyi, C. perfringens, or C. sordellii. The in vitro test will measure the antitoxin content of serum samples containing 100-1500 units of antitoxin. Tetanus antitoxin titers obtained by the competitive enzyme-linked immunosorbent assay compared favorably with the toxin neutralization test conducted in guinea pigs. The in vitro assay serves as a feasible alternative to the in vivo test because it can be completed in less time, is reproducible, and eliminates the use of test animals.  相似文献   

5.
Enzyme-linked immunosorbent assay for rat hepatic triglyceride lipase   总被引:1,自引:0,他引:1  
A noncompetitive enzyme-linked immunosorbent assay to measure rat hepatic triglyceride lipase (H-TGL) was developed. Antibodies to rat H-TGL were purified from goat antisera by immunoadsorption on an H-TGL-Sepharose 4B column. Routinely, Immulon 2 Removawell strips were coated with the purified antibody overnight at 4 degrees C. After blocking the wells with bovine serum albumin (BSA) for 2 hr at room temperature, standards (0.85 ng/ml-13.1 ng/ml) or samples were added to the wells and were incubated with the bound anti-rat H-TGL overnight at 4 degrees C. The standards and samples had been pretreated with 5-20 mM SDS for 30 min at room temperature and were then diluted so that the final SDS concentration in the assay was 1 mM or less. The pretreatment with SDS was necessary to achieve maximal immunoreactivity. The sample incubation was followed by an overnight incubation at 4 degrees C with an anti-rat H-TGL-horseradish peroxidase conjugate. Rat H-TGL was detected by the color development after the addition of 0.4 mg/ml of o-phenylenediamine in 0.01% H2O2, 0.1 M citrate phosphate, pH 5.0. A linear relationship was obtained between absorbance at 490 nm and the amount of highly purified rat H-TGL used as a standard. Inclusion of 1 M NaCl in the assay buffer (1% BSA, 0.05% Tween 20, 10 mM phosphate, pH 7.4) during the sample and conjugate incubations minimized non-specific interactions. Recoveries of purified rat H-TGL added to a rat liver perfusate sample ranged from 98.6% to 103%.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
Murine monoclonal antibodies reactive with at least one of the serological types of staphylococcal enterotoxin were examined for use in assay systems for the detection of enterotoxin at the level of 1.0 ng of enterotoxin per ml. An antibody sandwich enzyme-linked immunosorbent assay was devised for each toxin type by identifying an effective antibody pair. One antibody (the coating antibody) was coated onto a polystyrene plate and removed the enterotoxin from the test solution; the second antibody (the probing antibody) was conjugated to horseradish peroxidase and detected the captured toxin. Enterotoxins A and E could be detected in the same system by the use of cross-reacting monoclonal antibodies. All subtypes of enterotoxin C could be detected in one assay system. Two effective systems were described for each of types B and D. Each of these systems, when compared with the homologous enterotoxin-specific polyclonal rabbit antibody systems, was found to compare favorably. The monoclonal enzyme-linked immunosorbent assay systems for the detection of enterotoxins A and C2 were examined for a variety of food extracts; no abnormal interference could be detected from these extracts. The monoclonal antibody systems were also compared with the homologous enterotoxin-specific polyclonal serum for the detection of enterotoxin by the competitive radioimmunoassay (RIA). Single monoclonal antibodies generally did not perform as well in the RIA as did the homologous toxin-specific polyclonal serum. However, pools of monoclonal antibodies were prepared that approached the sensitivity and precision of the polyclonal system for the detection of each toxin by the RIA.  相似文献   

7.
Murine monoclonal antibodies reactive with at least one of the serological types of staphylococcal enterotoxin were examined for use in assay systems for the detection of enterotoxin at the level of 1.0 ng of enterotoxin per ml. An antibody sandwich enzyme-linked immunosorbent assay was devised for each toxin type by identifying an effective antibody pair. One antibody (the coating antibody) was coated onto a polystyrene plate and removed the enterotoxin from the test solution; the second antibody (the probing antibody) was conjugated to horseradish peroxidase and detected the captured toxin. Enterotoxins A and E could be detected in the same system by the use of cross-reacting monoclonal antibodies. All subtypes of enterotoxin C could be detected in one assay system. Two effective systems were described for each of types B and D. Each of these systems, when compared with the homologous enterotoxin-specific polyclonal rabbit antibody systems, was found to compare favorably. The monoclonal enzyme-linked immunosorbent assay systems for the detection of enterotoxins A and C2 were examined for a variety of food extracts; no abnormal interference could be detected from these extracts. The monoclonal antibody systems were also compared with the homologous enterotoxin-specific polyclonal serum for the detection of enterotoxin by the competitive radioimmunoassay (RIA). Single monoclonal antibodies generally did not perform as well in the RIA as did the homologous toxin-specific polyclonal serum. However, pools of monoclonal antibodies were prepared that approached the sensitivity and precision of the polyclonal system for the detection of each toxin by the RIA.  相似文献   

8.
An enzyme-linked immunosorbent assay was used to detect canine immunoglobulin G antibodies specific for infectious canine hepatitis virus and the serologically related canine adenovirus Type 2. The sequential development of homologous and heterologous antibodies was measured by the enzyme-linked immunosorbent assay and serum neutralization tests in two groups of dogs which were experimentally infected with either infectious canine hepatitis virus or canine adenovirus Type 2. Both tests were comparable in their abilities to detect the development of homologous and heterologous antibodies. Homologous antibodies were detected earlier and to a higher titer in both tests. There was a 98% agreement between the serum neutralization test and the enzyme-linked immunosorbent assay when sera from 224 random-source dogs were examined for infectious canine hepatitis virus antibodies. The enzyme-linked immunosorbent assay was found to be a highly efficient and rapid test to determine the immune status of dogs to infectious canine hepatitis virus and canine adenovirus Type 2.  相似文献   

9.
Abstract Using ligand blotting, it was found that partially purified cytolethal distending toxin prepared from and enterotoxigenic strain of Campylobacter jejuni , bound to two peptides of molecular masses of approximately 59 kDa and 45 kDa and to a single peptide of 59 kDa in protein blots prepared from HeLa and CHO cell membranes, respectively. In contrast, labile toxin of Escherichia coli and cholera toxin bound to a single peptide of the same molecular mass (15 kDa) on protein blots prepared from both CHO and HeLa cell crude membranes resolved by gel electrophoresis. This banding pattern was identical using SDS-solubilized membrane, with or without heat treatment, but no band was obtained when reduced (treatment with 2-mercaptoethanol) samples were used for the gel electrophoresis. The differences between receptors of cytolethal distending toxin and cholera toxin/labile toxin were exploited to develop a receptor-based enzyme-linked immunosorbent assay for detection of cytolethal distending toxin which involved the consecutive addition of either solubilized CHO or HeLa membranes, antigen and antibody. This enzyme-linked immunosorbent assay consistently detected crude cytolethal distending toxin diluted up to 16-fold. The receptor-based enzyme-linked immunosorbent assay for detection of cytolethal distending toxin developed in this study is a suitable alternative assay which can be performed easily in laboratories with minimal facilities and, more importantly, the results are available within a few hours as compared to times of up to 5 days in the conventional tissue culture detection of cytolethal distending toxin.  相似文献   

10.
AIMS: The aim of the study was to determine the presence of genes coding for alpha (cpa), beta (cpb), epsilon (etx), iota (iA) and enterotoxin (cpe) from Clostridium perfringens broiler chicken isolates, using multiplex PCR assay established in the study. METHODS AND RESULTS: The multiplex PCR assay was shown to be specific when tested with 10 C. perfringens strains representing different toxin types, and 15 strains of other bacterial species. All 118 broiler chicken C. perfringens isolates were shown to carry the cpa gene but not cpb, etx, iap or cpe genes, signifying that all isolates represented type A and were cpe-negative. CONCLUSIONS: The assay established in the study enables the simultaneous detection of the major toxin genes and the cpe gene from C. perfringens isolates. SIGNIFICANCE AND IMPACT OF THE STUDY: The present study offers a new primer pair for detecting cpa, combined with a multiplex PCR assay. In addition, the study provides data of the presence of different toxin genes in C. perfringens isolates obtained from broiler chickens.  相似文献   

11.
Polyethylene glycol-precipitated immune complexes (PIC) from the sera of 5 calves with Fasciola hepatica worm burdens ranging between 27 and 70 flukes were examined for parasite antigen content at 2, 4, 6, 8, 10, and 16 wk postinfection (PI) by the enzyme-linked immunosorbent assay (ELISA). Three assays were devised using an affinity-processed rabbit antibody to worm excretory/secretory (FhES) antigens. The PIC plate assay detected parasite antigen by adherence of anti-FhES antibody to PIC incubated overnight on ELISA plates, and tests were visualized using anti-rabbit peroxidase-linked antibody. The serum complex and PIC capture assay utilized the anti-FhES immunoglobulin as an antigen capture antibody linked to the solid phase. The attached complexes were then detected by the adhering bovine antibody, either soluble complexes in serum or as PIC. All assays showed circulating immune complex (CIC) values elevated at 6-8 wk PI, which generally coincided with increased host circulating antibody to FhES antigens. The greatest detection rate for all of the immune complex (IC) detection assays occurred with the PIC capture assay. It detected antigen in almost 90% of sera tested at 6 and 8 wk PI. Both the serum complex and PIC capture assay detected greatest amounts of CIC in those animals with the largest worm burdens, whereas the PIC plate assay showed no such trend. This study shows that F. hepatica antigen detection in CIC can be used to aid immunologic diagnosis of fascioliasis.  相似文献   

12.
AIMS: To develop a competitive agglutination inhibition assay (CAIA) for the detection of anti-Toxic Shock Syndrome Toxin-1 (TSST-1) antibody in serum samples using a commercially available reverse passive agglutination assay (RPLA) kit. METHODS AND RESULTS: TSST-1 toxin and sera were incubated together, so that anti-toxin IgG would complex with the toxin. Latex particles sensitized with rabbit IgG anti-TSST-1 were added to test for un-complexed toxin. The sensitivity and specificity of the CAIA assay was determined relative to positive and negative ELISA results. The sensitivity (proportion of positive ELISA sera which tested positive by CAIA) was 66% whilst the specificity (proportion of ELISA negative sera which tested negative by CAIA) was 75%. Seven sera (14%) were negative by ELISA but positive for CAIA and 12 (18.8%) were positive for ELISA but negative for CAIA, suggesting some interference with the assays. Statistical analysis showed no significant difference between the methods in terms of the numbers of individuals testing positive (chi2, P = 0.04). CONCLUSIONS: The CAIA assay allowed detection of anti-TSST-1 within 18 h and was simple to read visually. SIGNIFICANCE AND IMPACT OF THE STUDY: The method is a useful test for individual serum samples and a preliminary investigation for medical screening of suspected toxic shock syndrome and is applicable in situations where antibody assays are not routinely used for anti-TSST-1 and also where sophisticated equipment (e.g. microtitre plate reader) is not available.  相似文献   

13.
The use of simian agent 8 (SA8) as an antigen for B virus (BV) antibody detection was evaluated in cynomolgus monkeys. Seventy-two sera judged as positive using BV antigen were all positive when the SA8 antigen was used. Out of 28 BV-negative sera 2 were positive against the SA8 antigen and one serum was classified as indeterminate. The present data indicates that detection of BV antibody can be achieved accurately and safely by enzyme-linked immunosorbent assay (ELISA) using SA8 antigen.  相似文献   

14.
We have developed a sandwich enzyme-linked immunosorbent assay for serotyping dengue viruses. In this assay, we used antibody from dengue hemorrhagic fever patients for detection of flavivirus common antigens to confirm virus isolation in C6/36 cells and that from hyperimmune mouse ascitic fluids for serotyping. The anti-dengue antibody was immobilized on microplate wells for capturing of dengue antigens, which were then sandwiched with the same biotinylated antibody. Then the biotin in the solid phase was detected with peroxidase-conjugated streptavidin. We found that all the dengue strains tested were unequivocally identified by this method.  相似文献   

15.
Described is a rapid direct sandwich format electrochemiluminescence assay for identifying and assaying Clostridium perfringens alpha toxin. Biotinylated antibodies to C. perfringens alpha toxin bound to streptavidin paramagnetic beads specifically immunoadsorbed soluble sample alpha toxin which subsequently selectively immunoadsorbed ruthenium (Ru)-labeled detection antibodies. The ruthenium chelate of detection antibodies chemically reacted in the presence of tripropylamine and upon electronic stimulation emitted photons (electrochemiluminescence) that were detected by the photodiode of the detector. Elevated toxin concentrations increased toxin immunoadsorption and the specific immunoadsorption of Ru-labeled antibodies to alpha toxin, which resulted in increased dose-dependent electrochemiluminescent signals. The standardized assay was rapid (single 2.5-h coincubation of all reagents), required no wash steps, and had a sensitivity of about 1 ng/ml of toxin. The assay had excellent accuracy and precision and was validated in buffer, serum, and urine with no apparent matrix effects.  相似文献   

16.
After confirming that long-term serum storage (frozen at -20 C for greater than 3 mo) causes optical density to drift upward, several modifications of an enzyme-linked immunosorbent assay (ELISA) protocol were evaluated to identify a protocol that would reduce background in porcine sera tested for trichinellosis. Modifications evaluated included blocking the antigen-coated ELISA plate with sample diluent containing 10% bovine serum albumin (BSA) or 10% nonfat milk powder (bovine lacto transfer optimizer or BLOTTO), diluting sera in sample diluent containing 10% BSA or 10% BLOTTO, and preincubating samples in sample diluent containing 10% BSA or 10% BLOTTO. Overnight preincubation (approximately 12 hr at 2 C) of fresh sera diluted (1:10) in sample diluent containing 10% BLOTTO significantly reduced background and improved the detection of experimentally infected pigs by enhancing positive-negative discrimination. When testing stored sera, the modified protocol effectively reduced the effect of storage and the kit revealed specificity of 98.4%; there was no loss in sensitivity. The effect of long-term storage at -20 C must therefore be considered when testing swine sera for trichinellosis by ELISA and possibly also when conducting other immunoglobulin assays. The modification described here may prove useful if there is no alternative to using serum stored for greater than 3 mo at -20 C.  相似文献   

17.
A highly sensitive enzyme-linked immunosorbent assay (ELISA) for quantitation of Clostridium perfringens enterotoxin (CPE) by a sandwich method with polystyrene beads was elaborated. The ELISA was very sensitive with a detection limit of 1 pg/ml of CPE. Clostridium perfringens culture fluid did not interfere with the assay. This ELISA may be useful for the mass screening for Cl. perfringens producing small amounts of CPE.  相似文献   

18.
A competitive enzyme-linked immunosorbent assay was used to screen for T-2 toxin in Fusarium sporotrichioides -infected corn. The assay detected T-2 toxin in diluted methanol extracts of corn samples at concentrations of 0.05 ng/ml. In infected corn samples, enzyme-linked immunosorbent assay and gas-liquid chromatography estimations of T-2 toxin concentrations were similar.  相似文献   

19.
The methodological approach permitting the detection of immune complexes containing specific antibodies to a definite antigen in the enzyme-linked immunosorbent assay (ELISA) is described. The basic conditions of the assay were optimized. Immune complexes were precipitated from blood serum with 3.5% polyethylene glycol 6000 for 4 hours. The precipitate thus obtained was dissolved and incubated in polystyrene plates with immobilized antigen at 37 degrees C for a long time (at least 6 hours) in a humid chamber. The amount of bound antibodies, determined by ELISA techniques, was conjectured from the level of antigen-specific immune complexes. The proposed approach can be used in the immunodiagnosis of infectious diseases.  相似文献   

20.
Highly sensitive immunochromatographic test systems were developed for the detection of zearalenone (ZEA) and T-2 toxin (T2T) using magnetite nanoparticles (MNPs) for the labeling. In order to detect an analyte with high sensitivity, the competitive reaction was performed with free specific antibodies, while immune complexes were detected by the reaction with label-conjugated anti-species antibodies. The conditions for the synthesis of magnetite nanoparticles conjugated to anti-species antibodies were optimized. The concentrations of specific reagents that provided the highly sensitive detection of T-2 toxin and zearalenone were found. The instrumental detection limit for the determination of T-2 toxin and zearalenone in baby food samples (oat flakes) was 0.1 and 0.05 ng/mL (2.0 and 1.0 ng/g), respectively. The assay time was 15 min. The results of the present study confirm the possibility of the practical use of magnetite nanoparticles for immunochromatographic assay labeling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号