首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 16 毫秒
1.
The aim of this study is to develop an immunoaffinity sensor based on piezoelectric crystals for human serum albumin (HSA) detection in aqueous media. Quartz crystals were treated with ethylene diamine (EDA) plasma in a glow-discharge apparatus in order to substitute amino groups on their surfaces. Then anti-HSA antibodies were immobilized via these amino groups by using glutaraldehyde (GA) as cross-linker. Immobilization of the antibody on the quartz crystal was examined for different pH, antibody concentration and treatment time. The optimum conditions for anti-HSA immobilization were evaluated by the measurements of the activity of the surface against HSA. The optimum values of pH, antibody concentration and treatment time were found 6.2, 0.15 mg/ml and 2 h, respectively. For detection of HSA into the solution, two methods were used. In the first (dip and dry) method, the frequency shifts were measured in air after the 1 h interaction of the anti-HSA immobilized crystals with HSA solution. In the other (direct) method, the frequency shifts were followed continuously for 60 min. while the probe was immersed in the HSA solution. An increase for the frequency shifts was observed with increasing of HSA concentration of 16-128 microg/ml. Both the immobilization and antibody-interaction conditions were found important on the extend of these specific interaction. The relations between the HSA concentrations and frequency shifts were exponential in both methods.  相似文献   

2.
We report an electro-mechanical biosensor for electrical detection of proteins with disease markers using self-sensing piezoresistive micro-cantilevers. Electrical detection, via surface stress changes, of antigen-antibody (Ag-Ab) specific binding was accomplished through a direct nano-mechanical response of micro-fabricated self-sensing micro-cantilevers. A piezoresistive sensor measures the film resistance variation with respect to surface stress caused by biomolecules specific binding. When specific binding occurred on a functionalized Au surface, surface stress was induced throughout the cantilever, resulting in cantilever bending and resistance change of the piezoresistive layer. The cantilever biosensors were used for the detection of prostate specific antigen (PSA) and C-reactive proteins (CRP), which are a specific marker of prostate cancer and cardiac disease. From the above experiment, it was revealed that the sensor output voltage was proportional to the injected antigen concentration (without antigen, 10 ng/ml, 100 ng/ml, 1 microg/ml). PSA and CRP antibodies were found to be very specific for their antigens, respectively. This indicated that the self-sensing micro-cantilever approach is beneficial for detecting disease markers, and our piezoresistive micro-cantilever sensor system is applicable to miniaturized biosensor systems.  相似文献   

3.
A new competitive immunostrip assay was developed to detect human serum albumin (HSA) in urine sample with use of conjugated monoclonal antibody gold nanoparticles (mAb–AuNPs) and mobile crystalline material (MCM)-41–HSA bioconjugate. To prepare the immunostrip, the colloidal AuNPs with an average particle diameter of 20 nm, was synthesized, labeled with antibody and applied on the conjugate pad as the detection reagent. Then, HSA was attached to the MCM-41 mesoporous nanoparticles and immobilized to a nitrocellulose membrane as the test line. In the optimized investigational conditions, the immunostrip could detect HSA in a high linear range (from 1 to 200 μg/ml) and low detection limit (ng/ml). The reliability of the testing procedure was examined by performing the immunostrip test with 30 urine samples and comparing the results with those obtained via immunoturbidimetry. The immunostrip was adequately sensitive and accurate for a rapid screening of HSA in the urine. This new strategy for competitive immunostrip design can be used and developed for other antigen based immunostrip assay.  相似文献   

4.
Liu S  Yang Z  Liu Z  Kong L 《Analytical biochemistry》2006,353(1):108-116
Gold nanoparticles with a 12-nm diameter were used as probes for the determination of proteins by resonance Rayleigh-scattering techniques. In weak acidic solution, large amounts of citrate anions will self-assemble on the surface of positively charged gold nanoparticles to form supermolecular compounds with negative charges. Below the isoelectric point, proteins with positive charges such as human serum albumin (HSA), bovine serum albumin (BSA), and ovalbumin (Ova) can bind gold nanoparticles to form larger volume products (the diameter of the binding product of gold nanoparticles with HSA is 23 nm.) through electrostatic force, hydrogen bonds, and hydrophobic effects, which can result in a red shift of the maximum absorption wavelength, the remarkable enhancement of the resonance Rayleigh-scattering intensity (RRS), and the appearance of the RRS spectra. At the same time, the second-order-scattering (SOS) and frequency-doubling-scattering (FDS) intensities are also enhanced. The binding products of gold nanoparticles with different proteins have similar spectral characteristics and the maximum wavelengths are located near 303 nm for RRS, 540 nm for SOS, and 390 for FDS, respectively. The scattering enhancement (DeltaI) is directly proportional to the concentration of proteins. Among them, the RRS method has the highest sensitivity and the detection limits are 0.38 ng/ml for HSA, 0.45 ng/ml for BSA, and 0.56 ng/ml for Ova, separately. The methods have good selectivity. A new RRS method for the determination of trace proteins using a gold nanoparticle probe has been developed. Because gold nanoparticle probes do not need to be modified chemically in advance, the method is very simple and fast.  相似文献   

5.
In this study, electrical impedimetric biosensors composed of Au-electrodes were fabricated for the quantitative detection of human serum albumin (HSA), an essential biomarker of liver function. The Au-electrodes were fabricated via a single-step photolithography process, and can be easily integrated in biochips for assessing liver function in the future. The glass sensing surface between two adjacent Au-electrodes was modified with 3-aminopropyltriethoxysilane (APTES) to improve the biocompatibility for its subsequent binding to anti-human serum albumin (AHSA). The sensing surface without AHSA binding was blocked using skim milk powders, preventing possible non-specific bonding HSA conjugation. Biosensors were used to measure HSA concentration for liver function detection. The impedance between two adjacent Au-electrodes of the biosensors applied with various HSA concentrations was directly measured, and quantified using an electrochemical impedance spectroscopy system under AC conditions. The results of plotting both values in log scales indicated the impedance increased linearly with HSA conjugation increase. The limit of HSA detection was about 2'10(-4)mg/ml using the electrochemical impedimetric biosensor proposed in this work. This study demonstrates the feasibility of using electrochemical impedimetry as a bio-sensing mechanism to quantify human serum albumin concentration. The sensor proposed in this work also displays great potential for assessing liver function because of its simple detection mechanism, ease of biochip integration, and low cost.  相似文献   

6.
Label-free detection of bisphenol A based on the impedance measurement was achieved with an impedimetric immunosensor. The immunosensor was fabricated by the covalent bond formation between a polyclonal antibody and a carboxylic acid group functionalized onto a nano-particle comprised conducting polymer. By using a commercial reagent 4,4-bis(4-hydroxyphenyl) valeric acid (BHPVA), which has an analogous structure of BPA, we have prepared the antigen through the conjugation of BHPVA with bovine serum albumin (BSA) and then produced a specific polyclonal antibody. The immobilization of antibody and the interaction between antibody and antigen were studied using quartz crystal microbalance (QCM) and electrochemical impedance spectroscopic (EIS) techniques. The impedance and mass changes due to the specific immuno-interaction at the sensor surface were utilized to detect antigen and bisphenol A (BPA). The immunosensor showed specific recognition of BPA with less interference than 4.5% from other common phenolic compounds. Under an optimized condition, the linear dynamic range of BPA detection was between 1 and 100 ng/ml. The detection limit of bisphenol A was determined to be 0.3+/-0.07 ng/ml. The proposed immunosensor was applied to a human serum sample and the BPA concentration was determined by the standard addition method.  相似文献   

7.
An ion-sensitive field effect transistor (ISFET)-based immunosensor was developed to detect/quantitate beta-Bungarotoxin (beta-BuTx), a potent presynaptic neurotoxin from the venom of Bungarus multicinctus. A murine monoclonal antibody (mAb 15) specific to beta-BuTx was immobilized onto silicon nitride wafers after silanization and activation with glutaraldehyde. A chip based enzyme linked-immunosorbantassay (ELISA) was performed to ascertain antigen binding to the immobilized antibody. To develop an electrochemical immunosensing system for the detection/quantitation of beta-BuTx, an ISFET was used as a solid phase detector. MAb 15 was immobilized on the gate region of the ISFET. The antigen antibody reaction was monitored by the addition of urease conjugated rabbit anti-beta-BuTx antibodies. The sensor can detect toxin level as low as 15.6 ng/ml. The efficacy of the sensor for the determination of beta-BuTx from B. multicinctus venom was demonstrated in mouse model. Toxin concentration was highest at the site of injection (748.0+/-26 ng/ml) and moderate amount was found in the plasma (158.5+/-13 ng/ml).  相似文献   

8.
A new protein sensor is demonstrated by replacing the gate of a metal oxide semiconductor field effect transistor (MOSFET) with a nano-interdigitated array (nIDA). The sensor is able to detect the binding reaction of a typical antibody Ixodes ricinus immunosuppressor (anti-Iris) protein at a concentration lower than 1 ng/ml. The sensor exhibits a high selectivity and reproducible specific detection. We provide a simple model that describes the behavior of the sensor and explains the origin of its high sensitivity. The simulated and experimental results indicate that the drain current of nIDA-gate MOSFET sensor is significantly increased with the successive binding of the thiol layer, Iris and anti-Iris protein layers. It is found that the sensor detection limit can be improved by well optimizing the geometrical parameters of nIDA-gate MOSFET. This nanobiosensor, with real-time and label-free capabilities, can easily be used for the detection of other proteins, DNA, virus and cancer markers. Moreover, an on-chip associated electronics nearby the sensor can be integrated since its fabrication is compatible with complementary metal oxide semiconductor (CMOS) technology.  相似文献   

9.
The paper describes the rapid and label-free detection of the white spot syndrome virus (WSSV) using a surface plasmon resonance (SPR) device based on gold films prepared by electroless plating. The plating condition for obtaining films suitable for SPR measurements was optimized. Gold nanoparticles adsorbed on glass slides were characterized by transmission electron microscopy (TEM). Detection of the WSSV was performed through the binding between WSSV in solution and the anti-WSSV single chain variable fragment (scFv antibody) preimmobilized onto the sensor surface. Morphologies of the as-prepared gold films, gold films modified with self-assembled alkanethiol monolayers, and films covered with antibody were examined using an atomic force microscope (AFM). To demonstrate the viability of the method for real sample analysis, WSSV of different concentrations present in a shrimp hemolymph matrix was determined upon optimizing the surface density of the antibody molecules. The SPR device based on the electroless-plated gold films is capable of detecting concentration of WSSV as low as 2.5 ng/mL in 2% shrimp hemolymph, which is one to two orders of magnitude lower than the level measurable by enzyme-linked immunosorbant assays.  相似文献   

10.
A staphylococcal enterotoxin B magnetoelastic immunosensor   总被引:3,自引:0,他引:3  
A magnetoelastic immunosensor for detection of staphylococcal enterotoxin B (SEB) is described. The magnetoelastic sensor is a newly developed mass/elasticity-based transducer of high sensitivity having a material cost of approximately $0.001/sensor. Affinity-purified rabbit anti-SEB antibody was covalently immobilized on magnetoelastic sensors, of dimensions 6 mm x 2 mm x 28 microm. The affinity reaction of biotin-avidin and biocatalytic precipitation are used to amplify antigen-antibody binding events on the sensor surface. Horseradish peroxidase (HRP) and alkaline phosphatase were examined as the labeled enzymes to induce biocatalytic precipitation. The alkaline phosphatase substrate, 5-bromo-4-chloro-3-indolyl phosphate (BCIP) produces a dimer, which binds tightly to the sensor surface, inducing a change in sensor resonance frequency. The biosensor demonstrates a linear shift in resonance frequency with staphylococcal enterotoxin B concentration between 0.5 and 5 ng/ml, with a detection limit of 0.5 ng/ml.  相似文献   

11.
The Surface Plasmon Resonance Imaging (SPRI) sensor for papain determination based on the interaction between the immobilized cystatin and aqueous papain solution has been developed. The development of the sensor is a stage in the development of the sensor for the determination of cystein proteinases of the papain group. Cystatin was immobilized onto a gold chip by means of a thiol underlayer (cysteamine) and EDS/NHS reaction. Conditions of cystatin- papain interaction were optimized (pH, time of interaction and cystatin concentration). The developed sensor works within the range of 1 - 10 ng ml(-1). However, the precision of measurements (RSD equal to 45%) should be improved. The response of the sensor to papain is specific. This was checked using BSA as a reference.  相似文献   

12.
A magnetoelastic bioaffinity sensor coupled with biocatalytic precipitation is described for avidin detection. The non-specific adsorption characteristics of streptavidin on different functionalized sensor surfaces are examined. It is found that a biotinylated poly(ethylene glycol) (PEG) interface can effectively block non-specific adsorption of proteins. Coupled with the PEG immobilized sensor surface, alkaline phosphatase (AP) labeled streptavidin is used to track specific binding on the sensor. This mass-change-based signal is amplified by the accumulation on the sensor of insoluble products of 5-bromo-4-chloro-3-indolyl phosphate catalyzed by AP. The resulting mass loading on the sensor surface in turn shifts the resonance frequency of the magnetoelastic sensors, with an avidin detection limit of approximately 200 ng/ml.  相似文献   

13.
A flow injection analysis (FIA) system combined with Rayleigh light scattering (RLS) detection is developed for the sensitive and rapid determination of protein concentration in human serum sample. This method is based on the weak intensity of RLS of Eriochrome Black T (EBT, 2-hydroxy-1-(1-hydroxy-2-naphthylazo)-6-nitronaphthalene-4-sulfonic acid sodium salt), which can be enhanced by the addition of protein in weakly acidic solution. The effects of pH and interfering species on the determination of protein were examined. Calibrations for protein, based on RLS intensity, were linear in the concentration ranges of 7-36 microg/ml for human serum album (HSA) and 8-44 microg/ml for bovine serum album (BSA). The detection limits of the method were found to be 0.882 and 2.507 microg/ml for HSA and BSA, respectively. A relative standard deviation of 0.76% (n=5) was obtained with 20 microg/ml HSA standard solution. The FIA-RLS method was more stable than the general RLS method, and the average RSD value of FIA-RLS was less than that of the general RLS. The sample rate was determined to be 90 samples per hour.  相似文献   

14.
A disposable amperometric immunosensor was studied for the rapid detection of carp (Carassius auratus) Vitellogenin (Vtg). The sensor was fabricated based on screen-printed carbon arrays (SPCAs) containing eight carbon working and an integrated carbon counter electrodes. To construct the sensor, a conducting polymer (poly-terthiophene carboxylic acid) was electropolymerized on the surface of working electrodes and the polymer-coated SPCAs was characterized by SEM. Horseradish peroxidase (HRP) and a monoclonal antibody (anti-Vtg) specific to carp Vtg were covalently attached onto the polymer modified SPCAs. The immobilization of HRP and anti-Vtg onto the polymer-coated SPCAs was examined using cyclic voltammetry and quartz crystal microbalance studies. In order to detect the amount of Vtg, glucose oxidase (GOx)-labelled Vtg bound to the sensor surface under competition with the Vtg analyte was quantified amperometrically using glucose as a substrate. The performance of the eight sensors in arrays was evaluated by obtaining the calibration plots for Vtg. The sensor arrays exhibit a linear range of the Vtg concentration from 0.25 to 7.8 ng/ml and the detection limit was determined to be 0.09 ng/ml. Furthermore, the performance of the immunosensor for the determination of Vtg was evaluated by a standard addition method performed in fish serum samples.  相似文献   

15.
A rapid biosensor assay procedure that utilizes biotin streptavidin mediated filtration capture onto nitrocellulose membrane, in conjunction with a silicon-based light-addressable potentiometric sensor (LAPS) was developed for detection and identification of biological and chemical threat agents. Sandwich immunoassays, nucleic acid hybridization assays and enzyme inhibition assays are described. For immunoassays, the lower limits of detection (LOD) per 100-microl sample were approximately 5 pg/ml for protein (Staphylococcal enterotoxin B), 2 ng/ml for virus (Newcastle disease virus), and 20 ng/ml for vegetative bacteria (Brucella melitensis). In a dual gene probe assay format, the LOD was 0.30 fmol (1.8 x 10(8) copies per 60-microl) of single stranded target DNA. Enzyme inhibition assays on the LAPS using acetylcholinesterase were able to detect soman and sarin in aqueous samples at 2 and 8 pg (100 and 600 pM), respectively. The assays were easy to perform and required a total time equal to the reaction period plus about 15 min for filtering, washing and sensing. The assay format is suitable for detection of a wide range of infectious and toxic substances. New assays can be developed and optimized readily, often within 1 or 2 days.  相似文献   

16.
目的:建立高灵敏度的阿特拉津酶联免疫吸附检测法。方法:将间接竞争ELISA进行条件优化以提高检测灵敏度,包括包被抗原与一抗的最佳工作浓度筛选、选择一抗的最佳稀释度对包被抗原进行细化筛选、不同有机溶剂对竞争结合反应的影响、酶标二抗稀释度筛选等。用建立的酶联免疫检测法检测实际样品,再与高效液相色谱法(HPLC)检测进行比较。结果:利用优化后条件建立了阿特拉津间接竞争ELISA检测曲线,标准曲线的相关系数R2=0.9958,相关性较好。另由此标准曲线可得LOD (最低检出限)为1.972 ng/ml。用于检测实际样品,回收率在80%-120%之间。当添加样品浓度为(0~6) ng/ml时,该法的检测灵敏度高于HPLC。结论:新建立的阿特拉津ELISA特异性好、精密度高,可代替大型仪器用于阿特拉津实际样品检测。  相似文献   

17.
A Surface Plasmon Resonance Imaging (SPRI) sensor based on bromelain or chymopapain or ficin has been developed for specific cystatin determination. Cystatin was captured from a solution by immobilized bromelain or chymopapain or ficin due to the formation of an enzyme-inhibitor complex on the biosensor surface. The influence of bromelain, chymopapain or ficin concentration, as well as the pH of the interaction on the SPRI signal, was investigated and optimized. Sensor dynamic response range is between 0-0.6 μg/ml and the detection limit is equal to 0.1 μg/ml. In order to demonstrate the sensor potential, cystatin was determined in blood plasma, urine and saliva, showing good agreement with the data reported in the literature.  相似文献   

18.
An amperometric immunosensor for polycyclic aromatic hydrocarbons (PAHs) was developed. The immunosensor was based on disposable screen-printed carbon electrodes. The coating antigen used was phenanthrene-9-carboxaldehyde coupled to bovine serum albumin (BSA) via adipic acid dihydrazide. Antibodies were monoclonal mouse anti-phenanthrene. The enzyme alkaline phosphatase (AP) was used in combination with the substrate p-aminophenyl phosphate (pAPP) for detection at +300 mV (vs. Ag/AgCl). Various assay types were compared. Good results were achieved with an indirect co-exposure competition assay with a LOD of 0.8 ng/ml (800 ppt) and an IC(50) of 7.1 ng/ml (7.1 ppb) for phenanthrene. An indirect competition assay could detect phenanthrene with a LOD of 2 ng/ml (IC(50): 15 ng/ml) and an indirect displacement assay with a LOD of 2 ng/ml (IC(50): 11 ng/ml) at a 5 microl surface coating of 8.8 microg/ml phenanthrene-BSA conjugate. A coating concentration of 2.2 microg/ml allowed detection with a LOD of 0.25 ng/ml (250 ppt) with the indirect competition assay. The influence of the coating concentration on the sensor performance was investigated. Cross-reactivities were tested for 16 important PAHs. Anthracene and chrysene showed strong cross-reactivity, whereas benzo[g,h,i]perylene and dibenzo[a,h]anthracene showed no cross-reactivity.  相似文献   

19.
A fiber optic surface plasmon resonance (SPR) biosensor for detection of Staphylococcal enterotoxin B (SEB) is reported. The sensor is based on spectral interrogation of surface plasmons in a miniature sensing element based on a side-polished single-mode optical fiber with a thin metal overlayer. For specific detection of SEB, the SPR sensor is functionalized with a covalently crosslinked double-layer of antibodies against SEB. The SPR biosensor is demonstrated to be able to detect ng/ml concentrations of SEB in less than 10 min.  相似文献   

20.
Novel amperometric immunosensors based on iridium oxide matrices   总被引:7,自引:0,他引:7  
Novel immunosensors based on antibodies immobilized in electrochemically grown iridium oxide (IrOx) thin film matrices have been developed. Antibody loading in the oxide was evaluated using a non-competitive electrochemical immunoassay for IgG. Anti-IgG loading in the oxide was found to be dependent on the concentration of anti-IgG present in the oxide growth step, with 400 microg/ml anti-IgG producing maximum amperometric responses.To study the potential analytical properties of the matrix, the dose-response behavior of the sensors was determined using optimized alkaline phosphatase-linked IgG immunoassay. Hydroquinone diphosphate (HQDP) was used as enzyme substrate and the oxidation of hydroquinone was detected amperometrically at +420 mV. The sensors displayed a linear dose-response behavior for IgG concentrations between 10 and 200 ng/ml, saturating above 600 ng/ml, and had a low detection limit of 8 ng/ml.Finally, the method was used to produce sensors containing immobilized anti-transferrin. Using a non-optimized electrochemical immunoassay for human transferrin (HT), dose-response behavior was observed for HT concentrations between 100 and 600 ng/ml.The results presented in this paper show that IrOx matrices represent a new method for immunosensor fabrication. The oxide acts as a hydrophilic, highly porous, three-dimensional matrix that can immobilize antibodies and retain their activity. The method is attractive because it offers the potential for high antibody loadings and is suitable for mass production of sensors in an easy and economical manner.  相似文献   