首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
AimThe aim of this work is to present a method of beam weight and wedge angle optimization for patients with prostate cancer.Background3D-CRT is usually realized with forward planning based on a trial and error method. Several authors have published a few methods of beam weight optimization applicable to the 3D-CRT. Still, none on these methods is in common use.Materials and methodsOptimization is based on the assumption that the best plan is achieved if dose gradient at ICRU point is equal to zero. Our optimization algorithm requires beam quality index, depth of maximum dose, profiles of wedged fields and maximum dose to femoral heads. The method was tested for 10 patients with prostate cancer, treated with the 3-field technique. Optimized plans were compared with plans prepared by 12 experienced planners. Dose standard deviation in target volume, and minimum and maximum doses were analyzed.ResultsThe quality of plans obtained with the proposed optimization algorithms was comparable to that prepared by experienced planners. Mean difference in target dose standard deviation was 0.1% in favor of the plans prepared by planners for optimization of beam weights and wedge angles. Introducing a correction factor for patient body outline for dose gradient at ICRU point improved dose distribution homogeneity. On average, a 0.1% lower standard deviation was achieved with the optimization algorithm. No significant difference in mean dose–volume histogram for the rectum was observed.ConclusionsOptimization shortens very much time planning. The average planning time was 5 min and less than a minute for forward and computer optimization, respectively.  相似文献   

2.
3.
4.
AimTo compare the dose to organs at risk with free breathing (FB) or voluntary breath-hold (VBH) during radiotherapy of patients with left sided breast cancer.BackgroundRadiotherapy reduces the risk of breast-cancer-specific mortality but the effects on other organs increase non-cancer-specific mortality. Radiation exposure to the heart, in particular in patients with left sided breast cancer, can be reduced by breath hold methods that increase the distance between the heart and the radiation field.Materials and MethodsThree-dimensional conformal radiotherapy (3D-CRT) dose plans for the left breast and organs at risk including the heart, left anterior descending coronary artery (LAD) and ipsilateral lung were compared with FB and VBH in ten patients with left sided breast cancer.ResultsThe mean doses to the heart and LAD were reduced by 50.4 % (p < 0.001) and 58.8 % (p = 0.006), respectively, in VBH relative to FB. The mean dose to the ipsilateral lung was reduced by 13.8 % (p = 0.11) in VBH relative to FB. The planning target volume (PTV) coverage was at least 95 % in both FB and VBH (p = 0.78).ConclusionThe VBH technique significantly reduces the dose to organs at risk in 3D-CRT treatment plans of left sided breast cancer.  相似文献   

5.
PurposeTo show the usefulness of topographic 2D megavoltage images (MV2D) for the localization of breast cancer patients treated with TomoDirect (TD), a radiotherapy treatment technique with fixed-angle beams performed on a TomoTherapy system.MethodsA method was developed to quickly localize breast cancer patients treated with TD by registering the MV2D images produced before a TD treatment with reference images reconstructed from a kilovoltage CT simulation scanner and by using the projection of the beam-eye-view TD treatment field. Dose and image quality measurements were performed to determine the optimal parameters for acquiring MV2D images. A TD treatment was simulated on a chest phantom equipped with a breast attachment. MVCT and MV2D images were performed for 7 different shifted positions of the phantom and registered by 10 different operators with the simulation kilovoltage CT images.ResultsCompared to MVCT, MV2D imaging reduces the dose by a factor of up to 45 and the acquisition time by a factor of up to 49. Comparing the registration shift values obtained for the phantom images obtained with MVCT in the coarse mode to those obtained with MV2D, the mean difference is 1.0 ± 1.1 mm, −1.1 mm ± 1.1, and −0.1 ± 2.2 mm, respectively, in the lateral, longitudinal, and vertical directions.ConclusionsWith dual advantages (very fast imaging and a potentially reduced dose to the heart and contralateral organs), MV2D topographic images may be an attractive alternative to MVCT for the localization of breast cancer patients treated with TomoDirect.  相似文献   

6.
AimTo evaluate the performance of volumetric arc modulation with RapidArc against conventional IMRT for head and neck cancers.BackgroundRapidArc is a novel technique that has recently been made available for clinical use. Planning study was done for volumetric arc modulation with RapidArc against conventional IMRT for head and neck cancers.Materials and methodsTen patients with advanced tumors of the nasopharynx, oropharynx, and hypopharynx were selected for the planning comparison study. PTV was delineated for two different dose levels and planning was done by means of simultaneously integrated boost technique. A total dose of 70 Gy was delivered to the boost volume (PTV boost) and 57.7 Gy to the elective PTV (PTV elective) in 35 equal treatment fractions. PTV boost consisted of the gross tumor volume and lymph nodes containing visible macroscopic tumor or biopsy-proven positive lymph nodes, whereas the PTV elective consisted of elective nodal regions. Planning was done for IMRT using 9 fields and RapidArc with single arc, double arc. Beam was equally placed for IMRT plans. Single arc RapidArc plan utilizes full 360° gantry rotation and double arc consists of 2 co-planar arcs of 360° in clockwise and counter clockwise direction. Collimator was rotated from 35 to 45° to cover the entire tumor, which reduced the tongue and groove effect during gantry rotation. All plans were generated with 6 MV X-rays for CLINAC 2100 Linear Accelerator. Calculations were done in the Eclipse treatment planning system (version 8.6) using the AAA algorithm.ResultsDouble arc plans show superior dose homogeneity in PTV compared to a single arc and IMRT 9 field technique. Target coverage was almost similar in all the techniques. The sparing of spinal cord in terms of the maximum dose was better in the double arc technique by 4.5% when compared to the IMRT 9 field and single arc techniques. For healthy tissue, no significant changes were observed between the plans in terms of the mean dose and integral dose. But RapidArc plans showed a reduction in the volume of the healthy tissue irradiated at V15 Gy (5.81% for single arc and 4.69% for double arc) and V20 Gy (7.55% for single arc and 5.89% for double arc) dose levels when compared to the 9-Field IMRT technique. For brain stem, maximum dose was similar in all the techniques. The average MU (±SD) needed to deliver the dose of 200 cGy per fraction was 474 ± 80 MU and 447 ± 45 MU for double arc and single arc as against 948 ± 162 MU for the 9-Field IMRT plan. A considerable reduction in maximum dose to the mandible by 6.05% was observed with double arc plan. Double arc shows a reduction in the parotid mean dose when compared with single arc and IMRT plans.ConclusionRapidArc using double arc provided a significant sparing of OARs and healthy tissue without compromising target coverage compared to IMRT. The main disadvantage with IMRT observed was higher monitor units and longer treatment time.  相似文献   

7.
ObjectiveTo determine the optimum energy and beam arrangement for prostate intensity-modulated radiation therapy (IMRT) delivery using an Elekta Beam Modulator? linear accelerator, in order to inform decisions when commissioning IMRT for prostate cancer.MethodsCMS XiO was used to create IMRT plans for a prostate patient. Arrangements with 3, 5, 7, 9 and 11 equally spaced fields, containing both a direct anterior and a direct posterior beam were used, with both 6 MV and 10 MV photons. The effects of varying the maximum number of iterations, leaf increment, number of intensity levels and minimum segment size were investigated. Treatment plans were compared using isodose distributions, conformity indices for targets and critical structures, target dose homogeneity, body dose and plan complexity.ResultsTarget dose conformity and homogeneity and sparing of critical structures improved with an increasing number of beams, although any improvements were small for plans containing more than five fields. Set-ups containing a direct posterior field provided superior conformality around the rectum to anterior beam arrangements. Mean non-target dose and total number of monitor units were higher with 6 MV for all beam arrangements. The dose distribution resulting from seven 6 MV beams was considered clinically equivalent to that with five 10 MV beams.ConclusionMethods have been developed to plan IMRT treatments using XiO for delivery with a Beam Modulator? that fulfil demanding dose criteria, using many different set-ups. This study suggests that 6 MV photons can produce prostate IMRT plans that are comparable to those using 10 MV. Work is ongoing to develop a complete class solution.  相似文献   

8.
Background and purposeTomoDirect (TD) can only operate in free-breathing. The purpose of this study is to compare TD with breath-hold 3D conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) techniques for left breast treatments, and to determine if the lack of respiratory gating is a handicap for cardiac sparing.Materials and methods15 patients treated for left breast had two computed tomography simulation, in free breathing (FB) and in deep-inspiration breath-hold (DIBH). Four treatments were planned: TD-FB, 3DCRT-FB, 3DCRT-DIBH and IMRT-DIBH. Dose to PTV, heart, lungs, right breast and patient were compared.ResultsA slightly lower cardiac mean dose is found for 3DCRT-DIBH than for TD-FB group (1.99 Gy Vs 2.89 Gy, p = 0.0462), while no statistical difference is found for heart V20. TD-FB plans show the best PTV dose homogeneity (0.053, p < 0.001) and the lowest left lung mean dose (5.16 Gy, p < 0.001). No major differences are found for the other organs.ConclusionsTomoDirect and breath-hold 3DCRT are complementary techniques for left breast treatments: for a minority of patients, respiratory gating is mandatory to lower cardiac dose; for the remaining majority of patients, TomoDirect achieves better PTV homogeneity and reduced left lung dose, with cardiac dose equivalent to 3DCRT-DIBH.  相似文献   

9.
Background and purposeTo assess anatomic changes during intensity modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) and to determine its dosimetric impact.Patients and methodsTwenty patients treated with IMRT for NPC were enrolled in this study. A second CT was performed at 38 Gy. Manual contouring of the macroscopic tumor volumes (GTV) and the planning target volumes (PTV) were done on the second CT. We recorded the volumes of the different structures, D98 %, the conformity, and the homogeneity indexes for each PTV. Volume percent changes were calculated.ResultsWe observed a significant reduction in tumor volumes (58.56 % for the GTV N and 29.52 % for the GTV T). It was accompanied by a significant decrease in the D98 % for the 3 PTV (1.4 Gy for PTV H, p = 0.007; 0.3 Gy for PTV I, p = 0.03 and 1.15 Gy for PTV L, p = 0 0.0066). In addition, we observed a significant reduction in the conformity index in the order of 0.02 (p = 0.001) and 0.01 (p = 0.007) for PTV H and PTV I, respectively. The conformity variation was not significant for PTV L. Moreover, results showed a significant increase of the homogeneity index for PTV H (+ 0.03, p = 0.04) and PTV L (+ 0.04, p = 0.01).ConclusionTumor volume reduction during the IMRT of NPC was accompanied by deterioration of the dosimetric coverage for the different target volumes. It is essential that a careful adaptation of the treatment plan be considered during therapy for selected patients.  相似文献   

10.
AimThe objective of this study is to explore the use of volumetric arc therapy (VMAT) to perform total marrow irradiation (TMI) and compare its results to the standard TBI technique in the Mexican public health system.BackgroundThe standard total body irradiation (TBI) technique is used with chemotherapy as a method of a pre-transplant conditioning of the bone marrow. In this technique, the whole body of the patient is considered to be PTV and irradiated generating toxicities and raising concerns about possible development of radio-induced tumors.Materials and methodsThrough the use of simulation tomography of 12 patients previously treated with TBI, twelve different treatment plans were created with the proposed TMI technique and compared with the conventional protocol, the treatment plans were evaluated with a dose volume histogram analysis and quality assurance was evaluated with a portal dosimetry system using the gamma index criteria 3%/3 mm.ResultsExperimental results show an increasing dose to 99% of PTV of up to 41.1% by using TMI with the VMAT technique. The mean average dose to PTV was increased up to 19.3%. The use of the new TMI technique caused an improvement in the mean average dose to 99% of the PTV as well the homogeneity of the dose distribution prescribed at the PTV while leading to a better reproducibility of the treatment. The Qa of all the plans met the criterion of gamma index 3 mm-3%.ConclusionThe results analysis shows that the proposed TMI technique is feasible and applicable in the Mexican public health system.  相似文献   

11.
PurposeStudies using split field IMRT to spare dysphagia/aspiration related structures (DARS) have raised concern regarding dose uncertainty at matchline. This study explores the utility of hybrid VMAT in sparing the DARS and assesses matchline dose uncertainty in postoperative oral cavity cancer patients and compares it with VMAT.Methods & materialsTen postoperative oral cavity cancer patients were planned with h-VMAT and VMAT using the same planning CT dataset. PTV and DARS were contoured using standard delineation guidelines. In h-VMAT 80% of the neck dose was planned using AP/PA technique and then VMAT optimization was done for the total PTV by keeping the corresponding AP/PA plan as the base dose. Planning goal for PTV was V95%  95% and for DARS, adequate sparing. Plans and dose volume histograms were analyzed using dosimetric indices. Absolute point and portal dose measurements were done for h-VMAT plans to verify dose at the matchline.ResultsCoverage in both the techniques was comparable. Significant differences were observed in mean doses to DARS (Larynx: 24.36 ± 2.51 versus 16.88 ± 2.41 Gy; p < 0.0006, Pharyngeal constrictors: 25.16 ± 2.41 versus 21.2 ± 2.1 Gy; p < 0.005, Esophageal inlet: 18.71 ± 2 versus 12.06 ± 0.79 Gy; p < 0.0002) favoring h-VMAT. Total MU in both the techniques was comparable. Average percentage variations in point dose measurements in h-VMAT done at +3.5 and −3.5 positions were (1.47 ± 1.48 and 2.28 ± 1.35%) respectively. Average gamma agreement for portal dose measured was 97.07%.Conclusionh-VMAT achieves better sparing of DARS with no matchline dose uncertainty. Since these patients have swallowing dysfunction post-operatively, attempts should be made to spare these critical structures as much as possible.  相似文献   

12.
AimThis study aimed to investigate whether IMRT using VMAT is a viable and safe solution in dose escalated RT in these patients.BackgroundAn increasing number of prostate cancer patients are elderly and have hip prostheses. These implants pose challenges in radiotherapy treatment planning. Although intensity modulated radiotherapy (IMRT) is commonly used, there is a lack of clinical studies documenting its efficacy and toxicities in this subgroup of patients.Materials and methodsThe data from 23 patients with hip prostheses and non-metastatic prostate cancer treated with VMAT (volumetric modulated arc therapy) between 2009 and 2011, were retrospectively analyzed. Baseline characteristics, treatment details and outcome data were collected on all patients. The median follow up was 40.9 months. MRI-CT image fusion was performed and the treatment plans were created using RapidArc™ (RA) techniques utilizing 1 or 2 arcs and 10 MV photon beams.Results96% of patients were treated with a dose of 72 Gy/32 fractions over 44 days. 21/23 plans met the PTV targets. The mean homogeneity index was 1.07. 20/23 plans met all OAR constraints (rectum, bladder). Two plans deviated from rectal constraints, four from bladder constraints; all were classed as minor deviations. One patient experienced late grade 3 genitourinary toxicity. Three other patients experienced late grade 2 or lower gastrointestinal toxicity. One patient had biochemical failure and one had a non-prostate cancer related death.ConclusionsVMAT provides an elegant solution to deliver dose escalated RT in patients with unilateral and bilateral hip replacements with minimal acute and late toxicities.  相似文献   

13.
AimTo present the segmented photon beams technique (SPBT) for irradiation of postmastectomy patients.BackgroundIn majority of techniques for irradiation of posmastectomy patients, a few adjacent photon or electron beams were usually implemented in order to encompass different parts of the target. In the presented SPBT technique, the radiotherapy plan consists of 6 isocentric photon beams and the area CTV includes both the chest wall and the supraclavicular area. This makes it possible to provide a uniform dose to the CTV with no hot and cold points and enables the determination of doses for the entire volume of critical organs.Methods and materialThe treatment forward-IMRT plan comprises six isocentric 4 and 15 MV photon beams. Modulation of the dose distribution for each field was obtained by applying three segments on average. The total dose of 45 Gy was administered in 20 fractions. Dose distributions in target volume and organs at risk were evaluated for 70 randomly chosen patients.ResultsOn average, 94.8% of the CTV volume received doses within 95–107% of the prescribed dose. The average volume of the heart receiving a dose of 30 Gy and lager was 2% for patients with left breast cancer. The average dose to the lung on the irradiation side was always lower than 15.5 Gy and the average V20 Gy was below 35.5%.ConclusionsThe SPBT complies with requirements for high dose homogeneity within the target volume and satisfactory level of sparing of organs at risk.  相似文献   

14.
AimBiochemical relapse-free survival (bRFS) rate is determined by a cohort of Mexican patients (n = 595) with prostate cancer who received treatment with external radiotherapy.BackgroundPatients with prostate cancer were collected from CMN Siglo XXI (IMSS), CMN 20 de Noviembre (ISSSTE), and Hospital General de México (HGM). For the IMSS, 173 patients that are treated with three-dimensional conformal radiation therapy (3D-CRT) and 250 with SBRT, for the ISSSTE 57 patients are treated with 3D-CRT and on the HGM 115 patients are managed with intensity modulated radiation therapy (IMRT). The percentage of patients by risk group is: low 11.1%, intermediate 35.1% and high 53.8%. The average follow-up is 39 months, and the Phoenix criterion was used to determine the bRFS.Materials and methodsThe Kaplan–Meier technique for the construction of the survival curves and, the Cox proportional hazards to model the cofactors.Results(a) The bRFS rates obtained are 95.9% for the SBRT (7 Gy fx, IMSS), 94.6% for the 3D-CRT (1.8 Gy fx, IMSS), 91.3% to the 3D-CRT (2.65 Gy fx, IMSS), 89.1% for the SBRT (7.25 Gy fx, IMSS), 88.7% for the IMRT (1.8 Gy fx, HGM) %, and 87.7% for the 3D-CRT (1.8 Gy fx, ISSSTE). (b) There is no statistically significant difference in the bRFS rates by fractionation scheme, c) Although the numerical difference in the bRFS rate per risk group is 95.5%, 93.8% and 89.1% for low, intermediate and high risk, respectively, these are not statistically significant.ConclusionsThe RT techniques for the treatment of PCa are statistically equivalent with respect to the bRFS rate. This paper confirms that the bRFS rates of Mexican PCa patients who were treated with conventional vs. hypofractionated schemes do not differ significantly.  相似文献   

15.
PurposeTo assess the dosimetric impact of a patient positioning device for prone breast radiotherapy and assess the accuracy of a treatment planning system (TPS) in predicting this impact.MethodsBeam attenuation and build-up dose perturbations, quantified by ionization chamber and radiochromic film dosimetry, were evaluated for 3 components of the patient positioning device: the carbon fiber baseplate, the support cushions and the support wedge for the contralateral breast. Dose calculations were performed using the XVMC dose engine implemented in the Monaco TPS. All components were included during planning CT acquisition.ResultsBeam attenuation amounted to 7.57% (6 MV) and 5.33% (15 MV) for beams obliquely intersecting the couchtop–baseplate combination. Beams traversing large sections of the support wedge were attenuated by 12.28% (6 MV) and 9.37% (15 MV). For the support cushion foam, beam attenuation remained limited to 0.11% (6 MV) and 0.08% (15 MV) per centimeter thickness. A substantial loss of dose build-up was detected when irradiating through any of the investigated components. TPS dose calculations accurately predicted beam attenuation by the baseplate and support wedge. A manual density overwrite was needed to model attenuation by the support cushion foam. TPS dose calculations in build-up regions differed considerably from measurements for both open beams and beams traversing the device components.ConclusionsIrradiating through the components of the positioning device resulted in a considerable degradation of skin sparing. Inclusion of the device components in the treatment planning CT allowed to accurately model the most important attenuation effect, but failed to accurately predict build-up doses.  相似文献   

16.
《Endocrine practice》2015,21(2):143-157
ObjectiveSelf-adjustment of insulin dose is commonly practiced in Western patients with type 2 diabetes but is usually not performed in Asian patients. This multinational, 24-week, randomized study compared patient-led with physician-led titration of once-daily insulin glargine in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering agents.MethodsPatient-led (n = 275) or physician-led (n = 277) subjects followed the same dose-titration algorithm guided by self-monitored fasting blood glucose (FBG; target, 110 mg/dL [6.1 mmol/L]). The primary endpoint was change in mean glycated hemoglobin (HbA1c) at week 24 in the patient-led versus physician-led titration groups.ResultsPatient-led titration resulted in a significantly higher drop in HbA1c value at 24 weeks when compared with physician-led titration (− 1.40% vs. − 1.25%; mean difference, − 0.15; 95% confidence interval, − 0.29 to 0.00; P = .043). Mean decrease in FBG was greatest in the patient-led group (− 2.85 mmol/L vs. − 2.48 mmol/L; P = .001). The improvements in HbA1c and FBG were consistent across countries, with similar improvements in treatment satisfaction in both groups. Mean daily insulin dose was higher in the patient-led group (28.9 units vs. 22.2 units; P < .001). Target HbA1c of < 7.0% without severe hypoglycemia was achieved in 40.0% and 32.9% in the patient-led and physician-led groups, respectively (P = .086). Severe hypoglycemia was not different in the 2 groups (0.7%), with an increase in nocturnal and symptomatic hypoglycemia in the patient-led arm.ConclusionPatient-led insulin glargine titration achieved near-target blood glucose levels in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering drugs, demonstrating that Asian patients can self-uptitrate insulin dose effectively when guided. (Endocr Pract. 2015;21:143-157)  相似文献   

17.
PurposeTo verify lung stereotactic body radiotherapy (SBRT) plans using a secondary treatment planning system (TPS) as an independent method of verification and to define tolerance levels (TLs) in lung SBRT between the primary and secondary TPSs.MethodsA total of 147 lung SBRT plans calculated using X-ray voxel Monte Carlo (XVMC) were exported from iPlan to Eclipse in DICOM format. Dose distributions were recalculated using the Acuros XB (AXB) and the anisotropic analytical algorithm (AAA), while maintaining monitor units (MUs) and the beam arrangement. Dose to isocenter and dose-volumetric parameters, such as D2, D50, D95 and D98, were evaluated for each patient. The TLs of all parameters between XVMC and AXB (TLAXB) and between XVMC and AAA (TLAAA) were calculated as the mean ± 1.96 standard deviations.ResultsAXB values agreed with XVMC values within 3.5% for all dosimetric parameters in all patients. By contrast, AAA sometimes calculated a 10% higher dose in PTV D95 and D98 than XVMC. The TLAXB and TLAAA of the dose to isocenter were −0.3 ± 1.4% and 0.6 ± 2.9%, respectively. Those of D95 were 1.3 ± 1.8% and 1.7 ± 3.6%, respectively.ConclusionsThis study quantitatively demonstrated that the dosimetric performance of AXB is almost equal to that of XVMC, compared with that of AAA. Therefore, AXB is a more appropriate algorithm for an independent verification method for XVMC.  相似文献   

18.
AimTo report a single-institution experience using postoperative pelvic Intensity Modulation Radiation Therapy (IMRT) using tomotherapy accelerators (TA) in postoperative endometrial cancer (EC) regarding ICRU 83 recommendations.BackgroundIMRT in gynecological malignancies provides excellent dosimetric data, lower rates of adverse events and clinical data similar to historical series.Material and methodsSeventy-six patients with EC were postoperatively treated with adjuvant IMRT using TA. The IMRT dose was 45 Gy for patients without positive lymph nodes and Type I histology and 50.4 Gy for patients with positive lymph nodes and/or type II histology.ResultsWith a median follow-up of 29 months, the 12- and 24-month Overall Survival (OS) and Disease-Free Survival (DFS) were 96%, 93%, 87%, and 74%, respectively. Age of less than 60 years was associated with better OS (HR: 8.9; CI: 1.1–68) and DFS (HR: 3.5; CI: 1.2–10.2). Patients with Type II and Type I Grade III histology had a worse OS (HR: 3.3; CI: 1.1–11). Five women (6.6%) presented in-field local vaginal recurrence, 2 (2.6%) presented non-in-field vaginal recurrence, 4 (5.2%) presented pelvic node and distant recurrence and 11 (14.4%) presented only distant metastases. One patient stopped radiation treatment due to Grade III acute diarrhea. No Grade III late toxicity was observed. Planning Target Volume (PTV) coverage showed mean D2, D50, D95, and D98 of 51.64–46.23 Gy, 49.49–44.97 Gy, 48.62–43.96 Gy, and 48.47–43.58 Gy for patients who received 45 and 50.4 Gy, respectively.ConclusionsIMRT with TA in postoperative EC shows excellent conformity and homogeneity of PTV dose. Without Grade III late toxicity, data from this cohort demonstrated the utility of IMRT.  相似文献   

19.
AimTo compare the radiotherapy technique used in a randomised trial with VMAT and an in-house technique for prostate cancer.BackgroundTechniques are evolving with volumetric modulated arc therapy (VMAT) commonly used. The CHHiP trial used a 3 PTV forward planned IMRT technique (FP_CH). Our centre has adopted a simpler two PTV technique with locally calculated margins.Materials and methods25 patients treated with FP_CH to 60 Gy in 20 fractions were re-planned with VMAT (VMAT_CH) and a two PTV protocol (VMAT_60/52 and VMAT_60/48). Target coverage, conformity index (CI), homogeneity index (HI), monitor units (MU) and dose to the rectum, bladder, hips and penile bulb were compared.ResultsPTV coverage was high for all techniques. VMAT_CH plans had better CI than FP_CH (p   0.05). VMAT_60/52/48 plans had better CI than VMAT_CH. FP_CH had better HI and fewer MU than VMAT (p   0.05). More favourable rectum doses were found for VMAT _CH than FP_CH (V48.6, V52.8, V57, p   0.05) with less difference for bladder (p   0.05). Comparing VMAT_CH to VMAT_60/52/48 showed little differences for the bladder and rectum but VMAT_CH had larger penile bulb doses (V40.8, V48.6, mean, D2, p   0.05). Femoral head doses (V40.8) were similarly low for all techniques (p = ≥ 0.05).ConclusionVMAT produced more conformal plans with smaller rectum doses compared to FP_CH albeit worse HI and more MU. VMAT_60/52 and VMAT_60/48 plans had similar rectal and bladder doses to VMAT_CH but better CI and penile bulb doses which may reduce toxicity.  相似文献   

20.
ObjectiveTo assess the feasibility of treatment planning for pancreatic tumours subject to respiratory motion using field-specific target volumes (FTV) and field-specific organs at risk (FOAR) using four-dimensional computed tomography (4DCT).MethodsFourteen pancreatic cancer patients underwent 4DCT. Radiation oncologists contoured the gross tumour volume (GTV), clinical target volume (CTV), spinal cord, duodenum, kidneys, and stomach. The gating duty cycle was set to 30 % around exhalation. FTV and FOAR were calculated using the 4DCT dataset. Planning target volumes (PTV) and planning organs at risk volumes (PRV) were defined as equal to FTV and FOAR, respectively. A dose of 55.2 Gy relative biological effectiveness (RBE) was planned to target the PTV from four beam angles. A single field uniform dose (SFUD) plan was selected. The dose distribution, including intrafractional motion changes, was generated.ResultsThe mean volume of target receiving 95 % of the planned doses was 96.4 ± 4.1 % to the GTV and 94.7 ± 0.9 % to the CTV. The highest dose to 2 cc of duodenal volume was 27.5 Gy (RBE). The volume of the stomach receiving ⩾30 Gy (RBE) was <7.0 cc in all patients. All metrics for OARs satisfied dose constraints.ConclusionDose to the CTV was covered sufficiently by the 4DCT-generated FTV, and dose to OARs was reduced by 4DCT-generated FOAR. This methodology may prevent adverse reactions while preserving local tumour control.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号