首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
核酸适体在治疗、诊断和生物传感等领域都引起了强烈的关注和广泛的应用。与传统的识别元素-- 抗体相比较,适体展现 出很多的优点:尺寸小,化学性质稳定,容易制备和修饰。更重要的是适体在生物传感的设计上更为灵活,因此,产生了很多高选 择性、高灵敏度的新型适体传感器。目前,很多的检测手段都被应用到适体传感器中,其中荧光的检测手段占有重要的地位。虽然 荧光适体传感器已经取得了重大的进展,但是荧光标记给传感器的设计带来很多的不便,因此,免标记的荧光适体传感器备受关 注。在本文中,我们将对免标记的荧光适体传感器的研究进展进行综述,为分析工作者发展更加灵敏、更加简单、更加应用广泛的 免标记荧光适体传感器提供依据。  相似文献   

2.
Abstract

Early detection of tuberculosis (TB) reduces the interval between infection and the beginning of treatment. However, commercially available tests cannot discriminate between BCG-vaccinated healthy persons and patients. Also, they are not suitable to be used for immunocompromised persons. In recent years, biosensors have attracted great attention due to their simple utility, accessibility, and real-time outputs. These sensors are increasingly being considered as pioneering tools for point-of-care diagnostics in communities with a high burden of TB and limited accessibility to reference laboratories. Among other types of biosensors, the electrochemical sensors have the advantages of low-cost operation, fast processing, simultaneous multi-analyte analyzing, operating with turbid samples, comparable sensitivity and readily available miniaturization. Electrochemical biosensors are sub-divided into several categories including: amperometric, impedimetric, potentiometric, and conductometric biosensors. The biorecognition element in electrochemical biosensors is usually based on antibodies (immunosensors), DNAs or PNAs (genosensors), and aptamers (aptasensors). In either case, whether an interaction of the antigen–antibody/aptamer or the hybridization of probe with target mycobacterial DNA is detected, a change in the electrical current occurs that is recorded and displayed as a plot. Therefore, impedimetric-based methods evaluate resistance to electron transfer toward an electrode by a Nyquist plot and amperometric/voltammetric-based methods weigh the electrical current by means of cyclic voltammetry, square wave voltammetry, and differential pulse voltammetry. Electrochemical biosensors provide a promising scope for the new era of diagnostics. As a consequence, they can improve detection of Mycobacterium tuberculosis traces even in attomolar scales.  相似文献   

3.
Here, we report a sensitive amplified electrochemical impedimetric aptasensor for thrombin, a kind of serine protease that plays important role in thrombosis and haemostasis. For improving detection sensitivity, a sandwich sensing platform is fabricated, in which the thiolated aptamers are firstly immobilized on a gold substrate to capture the thrombin molecules, and then the aptamer functionalized Au nanoparticles (AuNPs) are used to amplify the impedimetric signals. Such designed aptamer/thrombin/AuNPs sensing system could not only improve the detection sensitivity compared to the reported impedimetric aptasensors but also provide a promising signal amplified model for aptamer-based protein detection. In this paper, we realize a sensitive detection limit of 0.02 nM, with a linear range of 0.05-18 nM. Meanwhile, the effect of 6-mercaptohexanol (MCH) and 2-mercaptoethanol (MCE) on the modification of the electrode is investigated.  相似文献   

4.
Aptamers as reagents for high-throughput screening   总被引:1,自引:0,他引:1  
Green LS  Bell C  Janjic N 《BioTechniques》2001,30(5):1094-6, 1098, 1100 passim
The identification of new drug candidates from chemical libraries is a major component of discovery research in many pharmaceutical companies. Given the large size of many conventional and combinatorial libraries and the rapid increase in the number of possible therapeutic targets, the speed with which efficient high-throughput screening (HTS) assays can be developed can be a rate-limiting step in the discovery process. We show here that aptamers, nucleic acids that bind other molecules with high affinity, can be used as versatile reagents in competition binding HTS assays to identify and optimize small-molecule ligands to protein targets. To illustrate this application, we have used labeled aptamers to platelet-derived growth factor B-chain and wheat germ agglutinin to screen two sets of potential small-molecule ligands. In both cases, binding affinities of all ligands tested (small molecules and aptamers) were strongly correlated with their inhibitory potencies in functional assays. The major advantages of using aptamers in HTS assays are speed of aptamer identification, high affinity of aptamers for protein targets, relatively large aptamer-protein interaction surfaces, and compatibility with various labeling/detection strategies. Aptamers may be particularly useful in HTS assays with protein targets that have no known binding partners such as orphan receptors. Since aptamers that bind to proteins are often specific and potent antagonists of protein function, the use of aptamers for target validation can be coupled with their subsequent use in HTS.  相似文献   

5.
Nucleic acid (aptasensors) have found steadily increased utility and application over the past decade. In particular, aptamers have been touted as a valuable complement to and, in some cases, replacement for antibodies owing to their structural and functional robustness as well as their ease in generation and synthesis. They are thus attractive for biosecurity applications (e.g. pathogen detection) and are especially well suited because their in vitro generation process does not require infection of any host systems. Herein we provide a brief overview of the aptamers generated against pathogens and toxins over the past few years. In addition, a few recently described detection platforms using aptamers and potentially suitable applications for biosecurity will be discussed.  相似文献   

6.
Colorimetric aptasensors using unmodified gold nanoparticles (AuNPs) have attracted much attention because of their low cost, simplicity, and practicality, and they have been developed for various targets in the past several years. However, previous research has focused on developing single-target assays. Here, we report the development of a homogeneous multiplex aptasensor by using more than one class of aptamers to stabilize AuNPs. Using sulfadimethoxine (SDM), kanamycin (KAN) and adenosine (ADE) as example targets, a KAN aptamer (750 nM), an SDM aptamer (250 nM) and an ADE aptamer (500 nM) were mixed at a 1∶1∶1 volume ratio and adsorbed directly onto the surface of unmodified AuNPs by electrostatic interaction. Upon the addition of any of the three targets, the conformation of the corresponding aptamer changed from a random coil structure to a rigid folded structure, which could not adsorb and stabilize AuNPs. The AuNPs aggregated in a specific reaction buffer (20 mM Tris-HCl containing 20 mM NaCl and 5 mM KCl), which led to a color change from red to purple/blue. These results demonstrate that the multiplex colorimetric aptasensor detected three targets simultaneously while maintaining the same sensitivity as a single-target aptasensor for each individual target. The multiplex aptasensor could be extended to other aptamers for various molecular detection events. Due to its simple design, easy operation, fast response, cost effectiveness and lack of need for sophisticated instrumentation, the proposed strategy provides a powerful tool to examine large numbers of samples to screen for a small number of potentially positive samples containing more than one analyte, which can be further validated using sophisticated instruments.  相似文献   

7.
Aptamers can control the biological functions of enzymes, thereby facilitating the development of novel biosensors. While aptamers that inhibit catalytic reactions of enzymes were found and used as signal transducers to sense target molecules in biosensors, no aptamers that amplify enzymatic activity have been identified. In this study, we report G-quadruplex (G4)-forming DNA aptamers that upregulate the peroxidase activity in myoglobin specifically for luminol. Using in vitro selection, one G4-forming aptamer that enhanced chemiluminescence from luminol by myoglobin''s peroxidase activity was discovered. Through our strategy—in silico maturation, which is a genetic algorithm-aided sequence manipulation method, the enhancing activity of the aptamer was improved by introducing mutations to the aptamer sequences. The best aptamer conserved the parallel G4 property with over 300-times higher luminol chemiluminescence from peroxidase activity more than myoglobin alone at an optimal pH of 5.0. Furthermore, using hemin and hemin-binding aptamers, we demonstrated that the binding property of the G4 aptamers to heme in myoglobin might be necessary to exert the enhancing effect. Structure determination for one of the aptamers revealed a parallel-type G4 structure with propeller-like loops, which might be useful for a rational design of aptasensors utilizing the G4 aptamer-myoglobin pair.  相似文献   

8.
The present study was aimed at the development and evaluation of a DNA electrochemical biosensor for Mycobacterium sp. genomic DNA detection in a clinical specimen using a signal amplifier as dual-labeled AuNPs. The DNA electrochemical biosensors were fabricated using a sandwich detection strategy involving two kinds of DNA probes specific to Mycobacterium sp. genomic DNA. The probes of enzyme ALP and the detector probe both conjugated on the AuNPs and subsequently hybridized with target DNA immobilized in a SAM/ITO electrode followed by characterization with CV, EIS, and DPV analysis using the electroactive species para-nitrophenol generated by ALP through hydrolysis of para-nitrophenol phosphate. The effect of enhanced sensitivity was obtained due to the AuNPs carrying numerous ALPs per hybridization and a detection limit of 1.25 ng/ml genomic DNA was determined under optimized conditions. The dual-labeled AuNP-facilitated electrochemical sensor was also evaluated by clinical sputum samples, showing a higher sensitivity and specificity and the outcome was in agreement with the PCR analysis. In conclusion, the developed electrochemical sensor demonstrated unique sensitivity and specificity for both genomic DNA and sputum samples and can be employed as a regular diagnostics tool for Mycobacterium sp. monitoring in clinical samples.  相似文献   

9.
A novel protocol for development of DNA electrochemical biosensor based on gold nanoparticles (AuNPs) modified glassy carbon electrode (GCE) was proposed, which was carried out by the self-assembly of AuNPs on the mercaptophenyl film (MPF) via simple electrografting of in situ generated mercaptophenyl diazonium cations. The resulting MPF was covalently immobilized on GCE surface via C-C bond with high stability, which was desirable in fabrication of excellent performance biosensors. Probe DNA was self-assembled on AuNPs through the well-known Au-thiol binding. The recognition of fabricated DNA electrochemical biosensor toward complementary single-stranded DNA was determined by differential pulse voltammetry with the use of Co(phen)(3)(3+) as the electrochemical indicator. Taking advantage of amplification effects of AuNPs and stability of MPF, the developed biosensor could detect target DNA with the detection limit of 7.2×10(-11) M, which also exhibits good selectivity, stability and regeneration ability for DNA detection.  相似文献   

10.
即时检测(point-of-care testing,POCT)是一种检测成本低、检测速度快、准确度高、能自我采样获得临床诊断结果的新型诊断技术。该技术在临床诊断、病情监控与疫情防控等领域发挥了重要作用。核酸适配体是一种能够特异性识别多种靶标的分子探针,具有易合成、批间差异小、易实现信号放大等突出优势,是生物医学传感器中重要的分子识别元件。本文概述了核酸适配体探针的现有筛选方法和进展,总结了核酸适配体POCT传感器信号放大策略,着重介绍了各类核酸适配体传感器在POCT领域的应用现状,并对核酸适配体POCT传感器的发展前景进行了展望。  相似文献   

11.
《Biophysical journal》2022,121(11):2193-2205
Nucleic-acid aptamers are bio-molecular recognition agents that bind to their targets with high specificity and affinity and hold promise in a range of biosensor and therapeutic applications. In the case of small-molecule targets, their small size and limited number of functional groups constitute challenges for their detection by aptamer-based biosensors because bio-recognition events may both be weak and produce poorly transduced signals. The binding affinity is principally used to characterize aptamer-ligand interactions; however, a structural understanding of bio-recognition is arguably more valuable in order to design a strong response in biosensor applications. Using a combination of nuclear magnetic resonance, circular dichroism, and isothermal titration calorimetry, we propose a binding model for a new methamphetamine aptamer and determine the main interactions driving complex formation. These measurements reveal only modest structural changes to the aptamer upon binding and are consistent with a conformational-selection binding model. The aptamer-methamphetamine complex formation was observed to be entropically driven, apparently involving hydrophobic and electrostatic interactions. Taken together, our results exemplify a means of elucidating small molecule-aptamer binding interactions, which may be decisive in the development of aptasensors and therapeutics and may contribute to a deeper understanding of interactions driving aptamer selection.  相似文献   

12.
Due to their high sensitivity, simplicity, portability, self‐contained, and low cost, the development of electrochemical biosensors is a beneficial way to diagnose and anticipate many types of cancers. An electrochemical nanocomposite‐based aptasensor is fabricated for the determination of miRNA‐128 concentration as the acute lymphoblastic leukemia (ALL) biomarker for the first time. The aptamer chains were immobilized on the surface of the glassy carbon electrode (GCE) through gold nanoparticles/magnetite/reduced graphene oxide (AuNPs/Fe3O4/RGO). Fast Fourier transform infrared (FTIR), X‐ray diffraction (XRD), vibrating sample magnetometer (VSM), and transmission electron microscopy (TEM) were used to characterize synthesized nanomaterials. Cyclic voltammetry (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS) were used to characterize the modified GCE in both label‐free and labeled methods. The results indicate that the modified working electrode has high selectivity and for miRNA‐128 over other biomolecules. The hexacyanoferrate redox system typically operated at around 0.3 V (vs. Ag/AgCl), and the methylene blue redox system ran at about 0 V, were used as an electrochemical probe. The detection limit and linear detection range for hexacyanoferrate and methylene blue are 0.05346 fM, 0.1–0.9 fM, and 0.005483 fM, 0.01–0.09 fM, respectively. The stability and diffusion control analyses were performed as well. In both label‐free and labeled methods, the modified electron showed high selectivity for miRNA‐128. The use of methylene blue as a safer redox mediator caused miRNA‐128 to be detected with greater accuracy at low potentials in PBS media. The findings also show the substantial improvement in detection limit and linearity by using reduced graphene oxide‐magnetite‐gold nanoparticles that can be verified by comparing with previous studies on the detection of other miRNAs.  相似文献   

13.
Biosensors for the detection of bacteria   总被引:4,自引:0,他引:4  
This review will consider the role of biosensors towards the detection of infectious bacteria, although non-infectious ones will be considered where necessary. Recently, there has been a heightened interest in developing rapid and reliable methods of detection. This is especially true for detection of organisms involved in bioterrorism, food poisoning, and clinical problems such as antibiotic resistance. Biosensors can assist in achieving these goals, and sensors using several of the different types of transduction modes are discussed: electrochemical, high frequency (surface acoustic wave), and optical. The paper concludes with a discussion of three areas that may make a great impact in the next few years: integrated (lab-on-a-chip) systems, molecular beacons, and aptamers.  相似文献   

14.
We have identified aptamers (synthetic oligonucleotides) binding to the very small molecule ethanolamine with high affinity down to the low nanomolar range. These aptamers were selected for their ability to bind to ethanolamine immobilised on magnetic beads, from an 96mer library of initially about 1 x 10(16) randomised ssDNA molecules. The dissociation constants of these aptamers range between K(D)=6 and K(D)=19 nmol L(-1). The aim of the development of ethanolamine aptamers is their use for the detection of this substance in clinical and environmental analysis. Ethanolamine is associated with several diseases. Moreover, ethanolamine and its derivatives di- and tri-ethanolamine are used in chemical and cosmetic industries. The use of biosensors with ethanolamine aptamer as new molecular recognition element could be an innovative method for an easy and fast detection of ethanolamine.  相似文献   

15.
Analytical applications of aptamers   总被引:17,自引:0,他引:17  
So far, several bio-analytical methods have used nucleic acid probes to detect specific sequences in RNA or DNA targets through hybridisation. More recently, specific nucleic acids, aptamers, selected from random sequence pools, have been shown to bind non-nucleic acid targets, such as small molecules or proteins. The development of in vitro selection and amplification techniques has allowed the identification of specific aptamers, which bind to the target molecules with high affinity. Many small organic molecules with molecular weights from 100 to 10,000 Da have been shown to be good targets for selection. Moreover, aptamers can be selected against difficult target haptens, such as toxins or prions. The selected aptamers can bind to their targets with high affinity and even discriminate between closely related targets.

Aptamers can thus be considered as a valid alternative to antibodies or other bio-mimetic receptors, for the development of biosensors and other analytical methods. The production of aptamers is commonly performed by the SELEX (systematic evolution of ligands by exponential enrichment) process, which, starting from large libraries of oligonucleotides, allows the isolation of large amounts of functional nucleic acids by an iterative process of in vitro selection and subsequent amplification through polymerase chain reaction.

Aptamers are suitable for applications based on molecular recognition as analytical, diagnostic and therapeutic tools. In this review, the main analytical methods, which have been developed using aptamers, will be discussed together with an overview on the aptamer selection process.  相似文献   


16.
A large amount of research within organic biosensors is dominated by organic electrochemical transistors (OECTs) that use conducting polymers such as poly(3,4-ethylene dioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS). Despite the recent advances in OECT-based biosensors, the sensing is solely reliant on the amperometric detection of the bioanalytes. This is typically accompanied by large undesirable parasitic electrical signals from the electroactive components in the electrolyte. Herein, we present the use of in situ resonance Raman spectroscopy to probe subtle molecular structural changes of PEDOT:PSS associated with its doping level. We demonstrate how such doping level changes of PEDOT:PSS can be used, for the first time, on operational OECTs for sensitive and selective metabolite sensing while simultaneously performing amperometric detection of the analyte. We test the sensitivity by molecularly sensing a lowest glucose concentration of 0.02 mM in phosphate-buffered saline solution. By changing the electrolyte to cell culture media, the selectivity of in situ resonance Raman spectroscopy is emphasized as it remains unaffected by other electroactive components in the electrolyte. The application of this molecular structural probe highlights the importance of developing biosensing probes that benefit from high sensitivity of the material's structural and electrical properties while being complimentary with the electronic methods of detection.  相似文献   

17.
纳米生物复合探针具有多功能复合、多检测路径、易于信号放大、制备简便等多种优越性。基于其优越的光学性质,人们可以利用常规光学设备实现生物检测,甚至可以实现目视检测。现就本实验室在光学纳米生物探针制备和应用的研究进展作一简要综述,所述纳米生物探针类型主要有:基于表面等离子体效应的纳米生物探针、基于量子效应的纳米生物探针和基于比表面效应的纳米生物探针,并介绍如何应用这些探针进行生物传感和生物芯片的构建。  相似文献   

18.
Aptamers are single-stranded DNA or RNA oligonucleotides, which are able to bind with high affinity and specificity to their target. This property is used for a multitude of applications, for instance as molecular recognition elements in biosensors and other assays. Biosensor application of aptamers offers the possibility for fast and easy detection of environmental relevant substances. Pharmaceutical residues, deriving from human or animal medical treatment, are found in surface, ground, and drinking water. At least the whole range of frequently administered drugs can be detected in noticeable concentrations. Biosensors and assays based on aptamers as specific recognition elements are very convenient for this application because aptamer development is possible for toxic targets. Commonly used biological receptors for biosensors like enzymes or antibodies are mostly unavailable for the detection of pharmaceuticals. This review describes the research activities of aptamer and sensor developments for pharmaceutical detection, with focus on environmental applications.  相似文献   

19.
适配子在生化分析中的应用进展   总被引:1,自引:0,他引:1  
适配子具有亲和力高、特异性强、靶分子范围广、稳定性好、制备及修饰容易、可重复利用等优点,可以作为与抗体竞争的一类分子识别物质,用于亲和PCR、生物传感器、适配子信标、色谱法、质谱法、毛细管电泳、流式细胞分析及荧光偏振等分析领域,显示出广阔的应用前景。  相似文献   

20.
适配体传感器在微生物检测中的应用   总被引:1,自引:0,他引:1  
适配体是一类特异的核酸序列,具有靶分子广、特异性强、稳定等优点.该类核酸分子在体外通过SELEX(systematic evolution of ligands by exponential enrichment)技术(系统进化的指数富集技术)鉴定和筛选得到.相对于抗体,适配体为诊断和检测分析系统中的识别配基提供了另一个选择.适配体生物传感器是将生物识别元件和信号转换元件紧密结合,从而检测目标化合物的分析装置.适配体生物传感器在微生物检测方面具有分析速度快、灵敏度高、专一性强等特点,在微生物检测中显示出良好的应用前景.介绍了适配体、SELEX流程以及适配体传感器,综述了适配体传感器在微生物检测中的应用.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号