首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Previous studies have shown greater fluorophore uptake during electroporation on the anode-facing side of the cell than on the cathode-facing side. Based on these observations, we hypothesized that hyperpolarizing a cell before electroporation would decrease the requisite pulsed electric field intensity for electroporation outcomes, thereby yielding a higher probability of reversible electroporation at lower electric field strengths and a higher probability of irreversible electroporation (IRE) at higher electric field strengths. In this study, we tested this hypothesis by hyperpolarizing HL-60 cells using ionomycin before electroporation. These cells were then electroporated in a solution containing propidium iodide, a membrane integrity indicator. After 20 min, we added trypan blue to identify IRE cells. Our results showed that hyperpolarizing cells before electroporation alters the pulsed electric field intensity thresholds for reversible electroporation and IRE, allowing for greater control and selectivity of electroporation outcomes.  相似文献   

2.
Prior studies have shown that electroporation is a simple and effective method for the introduction of oligonucleotides (ODN) into cells. In ex vivo bone marrow purging models, electroporation of ODN into cells has been associated with selective killing of human neoplastic cells while sparing hematopoietic stem cells. Prior studies used conventional electroporation methods (i.e., exponential decay) to introduce ODN into cells. Square wave electroporation allows the delivery of a more defined and regulated electrical pulse and is associated with high transfection efficiencies in a variety of systems. The current study was undertaken to determine whether square wave electroporation was more effective than exponential decay electroporation for the delivery of ODN into hematopoietic cells. Using fluorescein-tagged ODN and K562, chronic myelogenous leukemia (CML) cells, higher transfection rates were observed after square wave electroporation. In addition, c-myc antisense ODN were more effective in reducing c-myc protein when introduced by square wave electroporation, as compared with introduction by exponential decay electroporation. Square wave electroporation is thus identified as the optimal method for delivering ODN into hematopoietic cells.  相似文献   

3.
It is becoming increasingly apparent that electroporation is the most effective way to introduce plasmid DNA or siRNA into primary cells. The Gene Pulser MXcell electroporation system and Gene Pulser electroporation buffer (Bio-Rad) were specifically developed to easily transfect nucleic acids into mammalian cells and difficult-to-transfect cells, such as primary and stem cells. We will demonstrate how to perform a simple experiment to quickly identify the best electroporation conditions. We will demonstrate how to run several samples through a range of electroporation conditions so that an experiment can be conducted at the same time as optimization is performed. We will also show how optimal conditions identified using 96-well electroporation plates can be used with standard electroporation cuvettes, facilitating the switch from electroporation plates to electroporation cuvettes while maintaining the same electroporation efficiency. In the video, we will also discuss some of the key factors that can lead to the success or failure of electroporation experiments.Open in a separate windowClick here to view.(73M, flv)  相似文献   

4.
Electroporation is a common technique for the introduction of DNA molecules into living cells. The method is currently limited by the necessity of applying the electrical discharge to cells in suspension. Adherent cells must therefore be removed from their substratum, which can induce unwanted physiological effects. We report here a new procedure for in situ electroporation of cells grown on microporous membranes of polyethylene terephthalate (PET) or polyester (PE). We demonstrate that this method of in situ electroporation employs only readily available materials and standard electroporation devices without any modifications, is as efficient as conventional electroporation of cells in suspension, and is applicable to a wide range of cell types. Efficient electroporation can be achieved under conditions of minimal cell killing, and can be performed with quiescent cells as well as with confluent epithelial sheets. The method is a useful extension of electroporation technology, and will allow the application of electroporation to a wider spectrum of biological systems.  相似文献   

5.
This study is a survey of in vivo experiments on transfection of laboratory mouse muscle fibers by electroporation using an original device generating electric impulses. Transfection efficiency proved to depend on DNA dose and the number of electric impulses. It can be increased significantly by electroporation at varying pulse burst polarity. At both direct electrode application to muscles and electroporation through the skin, the muscle fiber transfection was more efficient under electroporation conditions much milder than those usually reported. The use of electroporation method for gene therapy of Duchenne muscular dystrophy is discussed.  相似文献   

6.
The mathematical solution to the electric field equation in cylindrical coordinates, has suggested to us a new experimental methodology and device for reducing experimental effort in designing electroporation protocols. Using a new cylindrical electroporation system, we show, with an Escherichia coli cell model, how key electroporation parameters emerge precisely from single experiments rather than through interpolation from numerous experiments in the conventional Cartesian electroporation system.  相似文献   

7.
Single metastable nanopores, appearing before the actual electroporation under constant-current conditions, are used to characterize the onset of electroporation. Unlike the long-lived electropores typical of the current controlled methods, these pores survive for milliseconds and observing them is possible due to slow development of electroporation, provided by the gradual accumulation of charges on a planar membrane. Analysis of the metastable pore appearance frequency and lifetime shows the first introductory stage of electroporation. During this stage two species of metastable pores open, the majority of very low conductance that seem not fully developed as hydrophilic electropores. The experiments reveal that voltage value defines the electroporation onset while the current value affects the rate of electroporation. Membrane capacitance has a great impact on the membrane susceptibility to the pore appearance, related to its thickness and integrity. Pores of nonperfect membranes appear more easily, but they do not live any longer than others.  相似文献   

8.
In this paper, we report the results of a systematic attempt to relate the intrinsic plasma membrane fluidity of three different cell lines to their electroporation behaviour, which consists of reversible and irreversible electroporation. Apart from electroporation behaviour of given cell lines the time course required for membrane resealing was determined in order to distinguish the effect of resealing time from the cell’s ability to survive given electric pulse parameters. Reversible, irreversible electroporation and membrane resealing were then related to cell membrane fluidity as determined by electron paramagnetic resonance spectroscopy and computer characterization of membrane domains. We found that cell membrane fluidity does not have significant effect on reversible electroporation although there is a tendency for the voltage required for reversible electroporation to increase with increased membrane fluidity. Cell membrane fluidity, however, may affect irreversible electroporation. Nevertheless, this effect, if present, is masked with different time courses of membrane resealing found for the different cell lines studied. The time course of cell membrane resealing itself could be related to the cell’s ability to survive.  相似文献   

9.
The optimization of electroporation conditions for maximal uptake of DNA during direct gene transfer experiments is critical to achieve high levels of gene expression in transformed plant cells. Two stains, trypan blue and fluorescein diacetate, have been applied to optimize electroporation conditions for three plant cell types, using different square wave and exponential wave electroporation devices. The different cell types included protoplasts from tobacco, a stable mixotrophic suspension cell culture from soybean with intact cell walls, and germinating pollen from alfalfa and tobacco. Successful electroporation of each of these cell types was obtained, even in the presence of an intact cell wall when conditions were optimized for the electroporation pulse. The optimal field strength for each of these cells differs, protoplasts having the lowest optimal pulse field strength, followed by suspension cells and finally germinating pollen requiring the strongest electroporation pulse. A rapid procedure is described for optimizing electroporation parameters using different types of cells from different plant sources.  相似文献   

10.
We show an inexpensive design for an electroporation chamber which subjects electroporated cells to a nonuniform electrical field. Our design, which we call an electroporation cylinder, improved transfection efficiency over that of a uniform field design (electroporation cuvettes) by about sixfold when tested in five mouse cell lines with a transient gene expression assay. Electroporation cylinders subjected cells to electrical field strengths at least as powerful as those of electroporation cuvettes, as judged by comparing the percentages of cells killed by electroporation. Cylinder and cuvette designs were similar in their effect on the variability of transfection efficiency. Electroporation cylinders may be particularly useful when the optimal electrical field strength for a cell line is not known or is unattainable with a given power supply.  相似文献   

11.
Introduction of antibody into viable cells using electroporation   总被引:1,自引:0,他引:1  
Conditions for labelling an intracellular antigen, p21ras, using electroporation to introduce a fluorescent antibody, are described. Following labelling, cells were evaluated for p21ras associated fluorescence by flow cytometry. Electroporation, sorting, and cell handling parameters were varied to determine optimal conditions for cell viability. Cells were best held in serum containing growth medium both before and after electroporation, while antibody introduction during the electroporation phase was most efficient when carried out in a balanced saline solution. For maximum efficiency of antibody internalization, the antibody needed to be present during electroporation, and medium needed to be replaced several times in the first few hours after electroporation to ensure good cell survival.  相似文献   

12.
脉冲电场利用方波直流脉冲发生器改变细胞膜的通透性,并在细胞膜上形成纳米级细孔,其被称为电穿孔是一种新型微创技术,分为可逆电穿孔(reversible electroporation)及不可逆电穿孔(irreversible electroporation)。在过去的四十年,电穿孔大量的实验研究及其自身的优点及先进性,使电穿孔相关的技术已被允许应用与临床。目前临床和实验中应用电穿孔的化疗药物已有十余种,通过电穿孔进行基因转染及DNA疫苗的研发已取得巨大成功。尤其近几年发展的非热能的不可逆电穿孔对实体肿瘤的消融作用,为肿瘤治疗提供新的思路,因其比其他局部治疗方法:具有治疗时间短,减少间接热损伤,对毗邻主要血管的肿瘤组织有消融能力等优点引起了对不可逆电穿孔巨大的临床研究兴趣。本文就电穿孔的基本理论,电化学治疗,基因电转染及不可逆电穿孔的临床应用进行探讨。  相似文献   

13.
A novel electroporation method using a capillary and wire-type electrode   总被引:1,自引:0,他引:1  
Electroporation is widely used to achieve gene transfection. A common problem in electroporation is that it has a lower viability than any other transfection method. In this study, we developed a novel electroporation device using a capillary tip and a pipette that was effective on a wide range of mammalian cells, including cell lines, primary cells, and stem cells. The capillary electroporation system considerably reduced cell death during electroporation because of its wire-type electrode, which has a small surface area. The experimental results also indicated that the cell viability was dependent on the change in pH induced by electrolysis during electroporation. Additionally, the use of a long and narrow capillary tube combined with simple pipetting shortened the overall time of the electroporation process by up to 15 min, even under different conditions with 24 samples. These results were supported by comparison with a conventional electroporation system. The transfection rate and the cell viability were enhanced by the use of the capillary system, which had a high transfection rate of more than 80% in general cell lines such as HeLa and COS-7, and more than 50% in hard-to-transfect cells such as stem or primary cells. The viability was approximately 70-80% in all cell types used in this study.  相似文献   

14.
用脂质体法和电穿孔法分别转染Cos-7,Vero和Namalwa细胞。发现脂质体法在转染效率和操作方便方面比电穿孔法优越,而电穿孔法对细胞种类的适应性方面比脂质体法广。电穿孔法能转染Cos-7、Namalwa和Vero细胞,而用脂质体法只能转染Cos-7和Vero细胞。  相似文献   

15.
Electrolysis, electrochemotherapy with reversible electroporation, nanosecond pulsed electric fields and irreversible electroporation are valuable non-thermal electricity based tissue ablation technologies. This paper reports results from the first large animal study of a new non-thermal tissue ablation technology that employs “Synergistic electrolysis and electroporation” (SEE). The goal of this pre-clinical study is to expand on earlier studies with small animals and use the pig liver to establish SEE treatment parameters of clinical utility. We examined two SEE methods. One of the methods employs multiple electrochemotherapy-type reversible electroporation magnitude pulses, designed in such a way that the charge delivered during the electroporation pulses generates the electrolytic products. The second SEE method combines the delivery of a small number of electrochemotherapy magnitude electroporation pulses with a low voltage electrolysis generating DC current in three different ways. We show that both methods can produce lesion with dimensions of clinical utility, without the need to inject drugs as in electrochemotherapy, faster than with conventional electrolysis and with lower electric fields than irreversible electroporation and nanosecond pulsed ablation.  相似文献   

16.
Efficient gene transfer is a key factor in gene therapy. Reducing the damage caused by gene transfer to muscle by electroporation is very important for its clinical application. Extensive investigation of optimal conditions for gene transfer by electroporation is required. The parameters used for electroporation, including plasmid concentration; injection volume; the plasmid dose of the injection; the concentration of saline media; the size of plasmid DNA; the age of the mice; the lag time between plasmid injection and electroporation; and the effect of repeated gene transfer by electroporation, were systematically investigated in the present study. The efficiencies of gene transfer by electroporation in normal and rodent models of diabetes were also evaluated. We found that electroporation used for non-viral gene transfer could be repeated in the same place in the muscle, but the expression efficiency was closely related to the muscle damage. Increasing pulse times could enhance the efficiency of gene transfer with a lower strength of electric field. It was better to use a higher plasmid concentration than to use a larger dose of plasmid and repeated injection to achieve a high level of transgene expression. Optimal conditions varied in different animal models, being milder for diabetic mice than for normal mice, and it was also shown that the conditions that worked well on these small rodents were not necessarily suitable for larger animals. Our results provide a comprehensive view of the factors that affect the efficiency of gene transfer into skeletal muscle by electroporation.  相似文献   

17.
It remained very difficult to manipulate gene expression in chick embryos until the advent of in ovo electroporation which enabled the induction of both gain-of-function, and recently loss-of-function, of a gene of interest at a specific developmental stage. Gain-of-function by electroporation is so effective that it has become widely adopted in developmental studies in the chick. Recently, it became possible to induce loss-of-function by introducing an siRNA expression vector by electroporation. In this review, the methods of electroporation for gain-of-function and for loss-of-function by siRNA are discussed.  相似文献   

18.
脂质体法和电穿孔法转染哺乳动物细胞研究   总被引:3,自引:0,他引:3  
用脂质体法和电穿孔法分别转染Cos-7,Vero和Namalwa细胞.发现脂质体法在转染效率和操作方便方面比电穿孔法优越,而电穿孔法对细胞种类的适用性方面似乎比脂质体法广. 结果表明,电穿孔法能转染Cos-7,Namalwa和Vero细胞,而用脂质体法只能转染Cos-7和Vero细胞.  相似文献   

19.
Increased transgene expression after plasmid transfer to the skeletal muscle is obtained with electroporation in many species, but optimum conditions are not well defined. Using a plasmid with a muscle-specific secreted embryonic alkaline phosphatase (SEAP) gene, we have optimized the electroporation conditions in a large mammal (pig). Parameters tested included electric field intensity, number of pulses, lag time between plasmid injection and electroporation, and plasmid delivery volume. Electric pulses, between 0.4 and 0.6 Amp constant current, applied 80 sec after the injection of 0.5 mg SEAP-expressing plasmid in a total volume of 2 mL produced the highest levels of expression. Further testing demonstrated that electroporation of a nondelineated injection site reduces the levels of SEAP expression. These results demonstrate that electroporation parameters such as amperage, lag time, and the number of pulses are able to regulate the levels of reporter gene expression in pigs.  相似文献   

20.
This study is a survey of in vivo experiments on transfection of laboratory mouse muscle fibers by electoporation using an original device generating electric impulses. Transfection efficiency proved to depend on DNA dose and the number of electric impulses. It can be increased significantly by electroporation at varying pulse burst polarity. At both direct electrode application to muscles and electroporation through the skin, the muscle fiber transfection was more efficient under electroporation conditions much milder than those usually reported. The use of electroporation method for gene therapy of Duchenne muscular dystrophy is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号