首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Changes of respiratory input impedance during breathing in humans.   总被引:4,自引:0,他引:4  
Changes of total respiratory resistance (Rrs) and reactance (Xrs) were studied between 8 and 32 Hz at five moments during the respiratory cycle in healthy adults (group A) and children (group B) and in patients with chronic obstructive lung disease (group C) and with upper airway obstruction (group D). Two forced oscillation techniques were used: the conventional one and the head generator, with the oscillations applied at the mouth and around the head of the subject, respectively. Both techniques yielded similar results. Rrs is lowest during the transition from inspiration to expiration and highest in the course of expiration, except in group D. Mean Xrs is highest at the transitions from inspiration to expiration or vice versa and lowest during expiration, except in group D. In groups C and D, the increases of Rrs are accompanied by a more pronounced negative frequency dependence of Rrs. The variations of Rrs and Xrs appear to be markedly flow dependent and may be a consequence of the interaction of breathing with oscillatory flows.  相似文献   

2.
Respiratory impedance (Zrs) was measured between 0.25 and 32 Hz in seven anesthetized and paralyzed patients by applying forced oscillation of low amplitude at the inlet of the endotracheal tube. Effective respiratory resistance (Rrs; in cmH2O.l-1.s) fell sharply from 6.2 +/- 2.1 (SD) at 0.25 Hz to 2.3 +/- 0.6 at 2 Hz. From then on, Rrs decreased slightly with frequency down to 1.5 +/- 0.5 at 32 Hz. Respiratory reactance (Xrs; in cmH2O.l-1.s) was -22.2 +/- 5.9 at 0.25 Hz and reached zero at approximately 14 Hz and 2.3 +/- 0.8 at 32 Hz. Effective respiratory elastance (Ers = -2pi x frequency x Xrs; in cmH2O/1) was 34.8 +/- 9.2 at 0.25 Hz and increased markedly with frequency up to 44.2 +/- 8.6 at 2 Hz. We interpreted Zrs data in terms of a T network mechanical model. We represented the proximal branch by central airway resistance and inertance. The shunt pathway accounted for bronchial distensibility and alveolar gas compressibility. The distal branch included a Newtonian resistance component for tissues and peripheral airways and a viscoelastic component for tissues. When the viscoelastic component was represented by a Kelvin body as in the model of Bates et al. (J. Appl. Physiol. 61: 873-880, 1986), a good fit was obtained over the entire frequency range, and reasonable values of parameters were estimated. The strong frequency dependence of Rrs and Ers observed below 2 Hz in our anesthetized paralyzed patients could be mainly interpreted in terms of tissue viscoelasticity. Nevertheless, the high Ers we found with low volume excursions suggests that tissues also exhibit plasticlike properties.  相似文献   

3.
Aortic input impedance was calculated in seven subjects in the control state (normal reflection) and during the Mueller maneuver (increased reflection) to evaluate "effective arterial length" under altered physiological conditions. Regional foot-to-foot pulse wave velocities and pressure waveforms along the aorta were used to define an "apparent anatomic length" or distance to a dominant discrete site of reflection "seen" by the ejecting ventricle. Time of wave travel was taken to be one-half the interval from the foot of the incident wave to the midsystolic inflection point. Knowing the time of travel from the returning reflection and velocity, distances calculated to the "apparent anatomic length" were 35 +/- 2 and 34 +/- 2 during control and Mueller maneuver, respectively (P = NS). The frequency of the first minimum of the modulus (fmin) and the first zero crossing of the phase angle (f phi) were determined from the input impedance spectra. During baseline conditions, fmin (3.9 +/- 0.2 Hz) approximately equaled f phi (4.2 +/- 0.2 Hz), and the resulting "effective lengths" calculated using the quarter-wavelength formula were similar to the apparent anatomic length. These data suggested that the aortic region incorporating the renal arterial branches as a site of discrete reflection and that terminal load was not significantly frequency dependent. During Mueller maneuver, however, f min (3.3 +/- 0.2 Hz) and f phi (5.1 +/- 0.2 Hz) were significantly discordant, the terminal load became strongly frequency dependent, and effective length calculated from f min was dissimilar (P less than 0.05) from the unchanged apparent anatomic length.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
Ascaris suum (AS) challenge in nonhuman primates is used as an animal model of human asthma. The primary goal of this study was to determine whether the airways and respiratory tissues in monkeys that are bronchoconstricted by AS inhalation behave similarly to those in asthmatic humans. Airway resistance (Raw) and tissue elastance (Eti) were estimated from respiratory system input (Zin) or transfer (Ztr) impedance. Zin (0.4-20 Hz) and Ztr (2-128 Hz) were measured in anesthetized cynomolgus monkeys (n = 10) under baseline (BL) and post-AS challenge conditions. Our results indicate that AS challenge in monkeys produces 1) predominantly an increase in Raw and not tissue resistance, 2) airway wall shunting at higher AS doses, and 3) heterogeneous airway constriction resulting in a decrease of lung parenchyma effective compliance. We investigated whether the airway and tissue properties estimated from Zin and Ztr were similar and found that Raw estimated from Zin and Ztr were correlated [r(2) = 0.76], not significantly different at BL (13.6 +/- 1.4 and 13.1 +/- 0.9 cmH(2)O. l(-1). s(-1), respectively), but significantly different post-AS (20.5 +/- 4.5 cmH(2)O. l(-1). s(-1) and 18.5 +/- 5.2 cmH(2)O. l(-1). s(-1)). There was no correlation between Eti estimated from Zin and Ztr. The changes in lung mechanical properties in AS-bronchoconstricted monkeys are similar to those recently reported in human asthma, confirming that this is a reasonable model of human asthma.  相似文献   

5.
6.
7.
8.
Cranial computed tomography has been performed in adults for the past 2 years but relatively few children have undergone this procedure. The specific uses in children are in detecting intracranial mass lesions and identifying the character of the lesion, and evaluating congenital cranial diseases such as cerebral dysplasia, tuberous sclerosis and leukodystrophies. This safe, rapid, noninvasive technique will soon replace or supplement standard neuroradiologic techniques in infants and children.  相似文献   

9.
10.
11.
12.
13.
14.

Background  

In Impedance Microbiology, the time during which the measuring equipment is connected to the bipolar cells is rather long, usually between 6 to 24 hrs for microorganisms with duplication times in the order of less than one hour and concentrations ranging from 101 to 107 [CFU/ml]. Under these conditions, the electrode-electrolyte interface impedance may show a slow drift of about 2%/hr. By and large, growth curves superimposed on such drift do not stabilize, are less reproducible, and keep on distorting all over the measurement of the temporal reactive or resistive records due to interface changes, in turn originated in bacterial activity. This problem has been found when growth curves were obtained by means of impedance analyzers or with impedance bridges using different types of operational amplifiers.  相似文献   

15.
When input impedance is determined by means of the forced oscillation technique, part of the oscillatory flow measured at the mouth is lost in the motion of the upper airway wall acting as a shunt. This is avoided by applying the oscillations around the subject's head (head generator) rather than at the mouth (conventional technique). In seven wheezing infants, we compared both techniques to estimate the importance of the upper airway wall shunt impedance (Zuaw) for the interpretation of the conventional technique results. Computation of Zuaw required, in addition, estimation of nasal impedance values, which were drawn from previous measurements (K. N. Desager, M. Willemen, H. P. Van Bever, W. De Backer, and P. A. Vermeire. Pediatr. Pulmonol. 11: 1-7, 1991). Upper airway resistance and reactance at 12 Hz ranged from 40 to 120 and from 0 to -150 hPa. l(-1). s, respectively. Varying nasal impedance within the range observed in infants did not result in major changes in the estimates of Zuaw or lung impedance (ZL), the impedance of the respiratory system in parallel with Zuaw. The conventional technique underestimated ZL, depending on the value of Zuaw. The head generator technique slightly overestimated ZL, probably because the pressure gradient across the upper airway was not completely suppressed. Because of the need to enclose the head in a box (which is not required with the conventional technique), the head generator technique is difficult to perform in infants.  相似文献   

16.
The excitable nature of a biological cell is manifested in the many voltage gated ion channels that perforate its membrane. The forms of the associated ionic currents, and in particular the functions that govern their kinetics, permit one to distinguish, electrophysiologically, between various cell types. We show, in the context of FitzHugh-Nagumo and Morris-Lecar models and without recourse to voltage or space clamping, that such currents and kinetics may be stably inferred from a cell’s voltage response to a specified input current.  相似文献   

17.
18.
19.
20.