首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe a method for pooling and sequencing DNA from a large number of individual samples while preserving information regarding sample identity. DNA from 576 individuals was arranged into four 12 row by 12 column matrices and then pooled by row and by column resulting in 96 total pools with 12 individuals in each pool. Pooling of DNA was carried out in a two-dimensional fashion, such that DNA from each individual is present in exactly one row pool and exactly one column pool. By considering the variants observed in the rows and columns of a matrix we are able to trace rare variants back to the specific individuals that carry them. The pooled DNA samples were enriched over a 250 kb region previously identified by GWAS to significantly predispose individuals to lung cancer. All 96 pools (12 row and 12 column pools from 4 matrices) were barcoded and sequenced on an Illumina HiSeq 2000 instrument with an average depth of coverage greater than 4,000×. Verification based on Ion PGM sequencing confirmed the presence of 91.4% of confidently classified SNVs assayed. In this way, each individual sample is sequenced in multiple pools providing more accurate variant calling than a single pool or a multiplexed approach. This provides a powerful method for rare variant detection in regions of interest at a reduced cost to the researcher.  相似文献   

2.
Kourkine IV  Hestekin CN  Magnusdottir SO  Barron AE 《BioTechniques》2002,33(2):318-20, 322, 324-5
Here we describe DNA sample preparation methods that allow the rapid, simultaneous generation of both single-stranded conformational polymorphism (SSCP) and heteroduplex DNA elements from a single sample in a single tube, which are suitable for direct injection into a capillary electrophoresis (CE) instrument with excellent sensitivity of genetic mutation detection. The p53 gene was used as a model DNA region for this study, which was performed on a high-throughput MegaBACE 96-capillary array electrophoresis instrument. We found that, contrary to the practice common in slab-gel SSCP analysis, denaturants such as formamide are incompatible with this novel technique because they result in homo- and heteroduplex peak broadening in CE (possibly as a result of incomplete dsDNA re-hybridization) that reduces the peak resolution and hence the sensitivity of mutation detection. We also have found that PCR buffers, which are typically used to suspend samples for slab-gel heteroduplex analysis (HA), but which are less suitable for CE because of the presence of extra salt that reduces the efficiency of electrokinetic injection, may be substituted with a 10 mM Tris-HCI buffer (pH 8.5). The use of this Tris-HCl buffer for sample preparation provides both a high sensitivity of mutation detection by tandem SSCP/HA and high efficiency ofelectrokinetic injection by CE. In a related study (published elsewhere), we have applied this optimized protocol to the screening of a set of 32 mutant DNA samples from p53 exons 7 and 8 and recorded 100% sensitivity of mutation detection for tandem CE-SSCP/HA, whereas each individual method yielded lower sensitivity on its own (93% for SSCP and 75% for HA).  相似文献   

3.
Post-PCR fragment analysis was conducted using our single photon detection-based DNA sequencing instrument in order to substantially enhance the detection of nucleic biomarkers. Telomerase Repeat Amplification Protocol assay was used as a model for real-time PCR-based amplification and detection of DNA. Using TRAPeze XL kit, telomerase-extended DNA fragments were obtained in extracts of serial 10-fold dilutions of telomerase-positive cells, then amplified and detected during 40-cycle real-time PCR. Subsequently, characteristic 6-base DNA ladder patterns were revealed in the post-PCR samples with capillary electrophoresis (CE). In our CE instrument, fluorescently labeled DNA fragments separate in a single-capillary module and are illuminated by a fiberized Ar-ion laser. The laser-induced fluorescence (LIF) is filtered and detected by the fiberized single photon detector (SPD). To assess the sensitivity of our instrument, we performed PCR at fewer cycles (29 and 25), so that the PCR machine could detect amplification only in the most concentrated samples, and then examined samples with CE. Indeed, PCR has detected amplification in samples with minimum 10(4) cells at 29 cycles and over 10(5) cells at 25 cycles. In contrast, the SPD-based CE-LIF has revealed 6-base repeats in samples with as low as 10(2) cells after 29 cycles and 10(3) cells after 25 cycles. Thus, we have demonstrated 100- to 1000-fold increase in the sensitivity of biomarker detection over real-time PCR, making our approach especially suitable for analysis of clinical samples where abundant PCR inhibitors often cause false-negative results.  相似文献   

4.
To our knowledge, we have developed a novel temperature-jump optical tweezers setup that changes the temperature locally and rapidly. It uses a heating laser with a wavelength that is highly absorbed by water so it can cover a broad range of temperatures. This instrument can record several force-distance curves for one individual molecule at various temperatures with good thermal and mechanical stability. Our design has features to reduce convection and baseline shifts, which have troubled previous heating-laser instruments. As proof of accuracy, we used the instrument to carry out DNA unzipping experiments in which we derived the average basepair free energy, entropy, and enthalpy of formation of the DNA duplex in a range of temperatures between 5°C and 50°C. We also used the instrument to characterize the temperature-dependent elasticity of single-stranded DNA (ssDNA), where we find a significant condensation plateau at low force and low temperature. Oddly, the persistence length of ssDNA measured at high force seems to increase with temperature, contrary to simple entropic models.  相似文献   

5.
Minisatellite analysis is commonly used in forensic disputes but can also be applied to the investigation of cell contamination. Such a problem arises, for example, when transplantation is performed. The presence of contamination has been investigated by other authors using radioactive methods. In the present study we describe a method that allows the detection of contamination with high sensitivity without using radioactive substances. Our technique is based on the use of polymerase chain reaction (PCR) amplification of minisatellite sequences (VNTR), followed by chemiluminescent detection. In particular, biotin-labelled dCTP is included in the PCR mixture and detection of PCR products is obtained following the CSPD chemiluminescent protocol (Southern-Light Nucleic Acid Detection Systems). We applied this method to artificial mixes of DNA of two individuals with alleles of different sizes. We performed progressive dilutions of an individual DNA into the other's DNA and revealed a contamination of 1 in 2500 cells. We also tested our technique searching for maternal contamination in cord blood samples in 60 cases and revealed a 18.3% contamination. The technique that we set up proves to be a very sensitive one which could be applied not only to the detection of maternal cells in cord blood but also in studying any other kind of contamination. © 1998 John Wiley & Sons, Ltd.  相似文献   

6.
7.
Single-molecule techniques facilitate analysis of mechanical transitions within nucleic acids and proteins. Here, we describe an integrated fluorescence and magnetic tweezers instrument that permits detection of nanometer-scale DNA structural rearrangements together with the application of a wide range of stretching forces to individual DNA molecules. We have analyzed the force-dependent equilibrium and rate constants for telomere DNA G-quadruplex (GQ) folding and unfolding, and have determined the location of the transition state barrier along the well-defined DNA-stretching reaction coordinate. Our results reveal the mechanical unfolding pathway of the telomere DNA GQ is characterized by a short distance (<1 nm) to the transition state for the unfolding reaction. This mechanical unfolding response reflects a critical contribution of long-range interactions to the global stability of the GQ fold, and suggests that telomere-associated proteins need only disrupt a few base pairs to destabilize GQ structures. Comparison of the GQ unfolded state with a single-stranded polyT DNA revealed the unfolded GQ exhibits a compacted non-native conformation reminiscent of the protein molten globule. We expect the capacity to interrogate macromolecular structural transitions with high spatial resolution under conditions of low forces will have broad application in analyses of nucleic acid and protein folding.  相似文献   

8.
The rapid detection and identification of infectious disease pathogens is a critical need for healthcare in both developed and developing countries. As we gain more insight into the genomic basis of pathogen infectivity and drug resistance, point-of-care nucleic acid testing will likely become an important tool for global health. In this paper, we present an inexpensive, handheld, battery-powered instrument designed to enable pathogen genotyping in the developing world. Our Microfluidic Biomolecular Amplification Reader (µBAR) represents the convergence of molecular biology, microfluidics, optics, and electronics technology. The µBAR is capable of carrying out isothermal nucleic acid amplification assays with real-time fluorescence readout at a fraction of the cost of conventional benchtop thermocyclers. Additionally, the µBAR features cell phone data connectivity and GPS sample geotagging which can enable epidemiological surveying and remote healthcare delivery. The µBAR controls assay temperature through an integrated resistive heater and monitors real-time fluorescence signals from 60 individual reaction chambers using LEDs and phototransistors. Assays are carried out on PDMS disposable microfluidic cartridges which require no external power for sample loading. We characterize the fluorescence detection limits, heater uniformity, and battery life of the instrument. As a proof-of-principle, we demonstrate the detection of the HIV-1 integrase gene with the µBAR using the Loop-Mediated Isothermal Amplification (LAMP) assay. Although we focus on the detection of purified DNA here, LAMP has previously been demonstrated with a range of clinical samples, and our eventual goal is to develop a microfluidic device which includes on-chip sample preparation from raw samples. The µBAR is based entirely around open source hardware and software, and in the accompanying online supplement we present a full set of schematics, bill of materials, PCB layouts, CAD drawings, and source code for the µBAR instrument with the goal of spurring further innovation toward low-cost genetic diagnostics.  相似文献   

9.
RNA and DNA strands produce ionic current signatures when driven through an alpha-hemolysin channel by an applied voltage. Here we combine this nanopore detector with a support vector machine (SVM) to analyze DNA hairpin molecules on the millisecond time scale. Measurable properties include duplex stem length, base pair mismatches, and loop length. This nanopore instrument can discriminate between individual DNA hairpins that differ by one base pair or by one nucleotide.  相似文献   

10.
In this study, we present a portable and generic DNA bioassay system based on in situ oligonucleotide synthesis followed by hybridization based detection. The system include two main parts, an oligonucleotide synthesizer and a fluorescence detection system. The oligonucleotide synthesizer is based on microfluidic technology and capable of synthesizing any desired oligonucleotide which can be either used as a primer for PCR based detection (external) or a probe for hybridization based detection (integrated) of a target DNA analyte. The oligonucleotide sequence can be remotely sent to the system. The integrated fluorescence detection system is based on a photodiode to detect Texas Red fluorophore as low as 0.5 fmol. The complete system, integrating the oligonucleotide synthesizer and fluorescence detection system, was successfully used to distinguish DNA from two different bacteria strains. The presented generic portable instrument has the potential to detect any desired DNA target sequence in the field. Potential applications are for homeland security and fast responses to emerging bio-threats.  相似文献   

11.
一种快速微量提取植物叶片DNA的方法   总被引:8,自引:1,他引:8  
介绍了一种快速提取微量DNA的方法。该方法简单易行,无需任何特殊设备,所需样品量少。提取的DNA纯度高,D260nm/D280nm在1.9-2.1之间,可满足RAPD、SSR、转基因植株的PCR检测等以PCR扩增为基础的实验需要。  相似文献   

12.
Molecular methods have become an important tool for studying feeding interactions under natural conditions. Despite their growing importance, many methodological aspects have not yet been evaluated but need to be considered to fully exploit the potential of this approach. Using feeding experiments with high alpine carabid beetles and lycosid spiders, we investigated how PCR annealing temperature affects prey DNA detection success and how post-PCR visualization methods differ in their sensitivity. Moreover, the replicability of prey DNA detection among individual PCR assays was tested using beetles and spiders that had digested their prey for extended times postfeeding. By screening all predators for three differently sized prey DNA fragments (range 116-612 bp), we found that only in the longest PCR product, a marked decrease in prey detection success occurred. Lowering maximum annealing temperatures by 4 °C resulted in significantly increased prey DNA detection rates in both predator taxa. Among the three post-PCR visualization methods, an eightfold difference in sensitivity was observed. Repeated screening of predators increased the total number of samples scoring positive, although the proportion of samples testing positive did not vary significantly between different PCRs. The present findings demonstrate that assay sensitivity, in combination with other methodological factors, plays a crucial role to obtain robust trophic interaction data. Future work employing molecular prey detection should thus consider and minimize the methodologically induced variation that would also allow for better cross-study comparisons.  相似文献   

13.
14.
Microscopy-based fluorescence resonance energy transfer (FRET) experiments measure donor and acceptor intensities by isolating these signals with a series of optical elements. Because this filtering discards portions of the spectrum, the observed FRET efficiency is dependent on the set of filters in use. Similarly, observed FRET efficiency is also affected by differences in fluorophore quantum yield. Recovering the absolute FRET efficiency requires normalization for these effects to account for differences between the donor and acceptor fluorophores in their quantum yield and detection efficiency. Without this correction, FRET is consistent across multiple experiments only if the photophysical and instrument properties remain unchanged. Here we present what is, to our knowledge, the first systematic study of methods to recover the true FRET efficiency using DNA rulers with known fluorophore separations. We varied optical elements to purposefully alter observed FRET and examined protein samples to achieve quantum yields distinct from those in the DNA samples. Correction for calculated instrument transmission reduced FRET deviations, which can facilitate comparison of results from different instruments. Empirical normalization was more effective but required significant effort. Normalization based on single-molecule photobleaching was the most effective depending on how it is applied. Surprisingly, per-molecule γ-normalization reduced the peak width in the DNA FRET distribution because anomalous γ-values correspond to FRET outliers. Thus, molecule-to-molecule variation in gamma has an unrecognized effect on the FRET distribution that must be considered to extract information on sample dynamics from the distribution width.  相似文献   

15.
In this work, we report a new fluorescent method for the label-free assay of thiol-containing amino acids and peptide by use of silver deposited DNA duplex and the intercalating dye. The sensing approach is based on the specific interactions between thiols and DNA-templated silver deposition via robust Ag-S bonds. In the presence of thiols, the intercalating dye gives a dramatic increase in fluorescence as a result of the strong interaction between the intercalator and the released DNA from silver surfaces. The detection limit of this method is lower than or at least comparable to previous fluorescence-based methods, and the turn-on sensing mode offers additional advantage to efficiently reduce background noise. Moreover, the detection and discrimination process can be observed by the naked eye with the aid of an UV transilluminator. This method also exhibits excellent selectivity for these thiol-containing biomolecules over various other amino acids. As far as we know, our method is the first example using the specific interaction between thiols and silver-coated DNA to fabricate a turn-on fluorescent sensor for biological thiols with high sensitivity and selectivity.  相似文献   

16.
High-quality nucleic acids are critical for optimal PCR-based diagnostics and pathogen detection. Rapid sample processing time is important for the earliest administration of therapeutic and containment measures, especially in the case of biothreat agents. In this context, we compared the Fujifilm QuickGene-Mini80 to Qiagen's QIAamp Mini Purification kits for extraction of DNA and RNA for potential use in austere settings. Qiagen (QIAamp) column-based extraction is the currently recommended purification platform by United States Army Medical Research Institute for Infectious Diseases for both DNA and RNA extraction. However, this sample processing system requires dedicated laboratory equipment including a centrifuge. In this study, we investigated the QuickGene-Mini80, which does not require centrifugation, as a suitable platform for nucleic acid extraction for use in resource-limited locations. Quality of the sample extraction was evaluated using pathogen-specific, real-time PCR assays for nucleic acids extracted from viable and γ-irradiated Bacillus anthracis, Yersinia pestis, vaccinia virus, Venezuelan equine encephalitis virus, or B. anthracis spores in buffer or human whole blood. QuickGene-Mini80 and QIAamp performed similarly for DNA extraction regardless of organism viability. It was noteworthy that γ-irradiation did not have a significant impact on real-time PCR for organism detection. Comparison with QIAamp showed a less than adequate performance of the Fujifilm instrument for RNA extraction. However, QuickGene-Mini80 remains a viable alternative to QIAamp for DNA extraction for use in remote settings due to extraction quality, time efficiency, reduced instrument requirements, and ease of use.  相似文献   

17.
Surface plasmon field-enhanced fluorescence spectroscopy (SPFS) utilizes the evanescent electromagnetic field of a surface plasmon to excite chromophors in close proximity to the surface. While conventional surface plasmon resonance spectroscopy allows the observation of surface reactions by means of refractive index changes, SPFS additionally provides a channel for the read-out of fluorescence changes. Thus, the detection limit for low mass compounds, whose adsorption is only accompanied by small refractive index changes, can be substantially improved by fluorescent labeling. In this study, we present the first example that utilizes SPFS to follow the dynamics of an enzymatic reaction. The elongation of surface-tethered DNA has been observed by the incorporation of Cy5-labeled nucleotides into the nascent strand by the action of DNA polymerase I (Klenow fragment). The technique offers a rapid way to determine the binding constant and the catalytic activity of a DNA processing enzyme, here exemplified by the Klenow fragment. Furthermore, the effect of mispaired bases in the primer/template duplex and the influence of different label densities have been studied. The resulting sensitivity for nucleotide incorporation, being in the femtomolar regime, combined with the specificity of the enzyme for fully complementary DNA duplexes suggest the application of this assay as a powerful tool for DNA detection.  相似文献   

18.
A validated PCR-based Salmonella method targeting a 94-bp sequence of the ttr gene was used as a model to compare six different combinations of reporter and quencher dyes of a TaqMan probe, on three different instruments, to improve the detection limit in a real-time PCR assay with the aim of a same-day analysis. The use of locked nucleic acids (LNA) and Scorpion probes were also tested. The combination FAM-BHQ1 or Cy5-BHQ3, both dark quenchers, gave the best results (Cycle threshold (Ct) of 25.42+/-0.65 and 24.47+/-0.18 at 10(3) DNA copies). When comparing different probe technologies, the LNA probe (FAM-BHQ1) was the most sensitive with the strongest fluorescence signal (dR last 48066), resulting in 0.6 to 1.1 lower Ct values than a DNA TaqMan probe, and 1.9 to 4.0 lower Ct than the Scorpion system (FAM-BHQ1). The RotorGene real-time PCR instrument gave 0.4-1.0 lower Ct values (more sensitive) than the Mx3005p, and 1.5-3.0 lower than the ABI 7700. Using the LNA in a RotorGene instrument, we detected the following Salmonella DNA copies in 1-ml pre-enriched samples: fishmeal (100 copies), chicken rinse (100 copies) and pig feces (10 copies). The detection probability of the final assay on inoculated fecal samples was 100% at 2x10(4) copies per ml. In conclusion, the LNA probe with annealing temperature of 65 degrees C could be useful for more sensitive detection limits.  相似文献   

19.
Capillary gel electrophoresis has been demonstrated for the separation and detection of DNA sequencing samples. Enzymatic dideoxy nucleotide chain termination was employed, using fluorescently tagged oligonucleotide primers and laser based on-column detection (limit of detection is 6,000 molecules per peak). Capillary gel separations were shown to be three times faster, with better resolution (2.4 x), and higher separation efficiency (5.4 x) than a conventional automated slab gel DNA sequencing instrument. Agreement of measured values for velocity, resolution and separation efficiency with theory, predicts further improvements will result from increased electric field strengths (higher voltages and shorter capillaries). Advantages of capillary gel electrophoresis for automatic DNA sequencing instruments and for genomic sequencing are discussed.  相似文献   

20.
An instrument combining scanning electron microscopy (SEM) and light microscopy (LM) was used to study the cell surface characteristics and DNA content of macrophages in murine bone marrow cultures. After a quantitative Feulgen DNA staining, the DNA content of the individual macrophages was measured and their cell surface morphology was studied immediately thereafter with the SEM part of the instrument. The cells were divided into six groups according to the number of microvilli and/or microridges present on their surface. A proportion of macrophages showed a DNA content more than occurs in diploid cells, which could indicate a future division. No special surface morphology could be detected in this cell type.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号