首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.

Purpose

There is a long-standing interest in the study of retinal blood flow in humans. In the recent years techniques have been established to measure retinal perfusion based on optical coherence tomography (OCT). In the present study we used a technique called dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT) to characterize the effects of 100% oxygen breathing on retinal blood flow. These data were compared to data obtained with a laser Doppler velocimeter (LDV).

Methods

10 healthy subjects were studied on 2 study days. On one study day the effect of 100% oxygen breathing on retinal blood velocities was studied using dual-beam bidirectional Doppler FD-OCT. On the second study day the effect of 100% oxygen breathing on retinal blood velocities was assessed by laser Doppler velocimetry (LDV). Retinal vessel diameters were measured on both study days using a commercially available Dynamic Vessel Analyzer. Retinal blood flow was calculated based on retinal vessel diameters and red blood cell velocity.

Results

As expected, breathing of pure oxygen induced a pronounced reduction in retinal vessel diameters, retinal blood velocities and retinal blood flow on both study days (p<0.001). Blood velocity data correlated well between the two methods applied under both baseline as well as under hyperoxic conditions (r = 0.98 and r = 0.75, respectively). Data as obtained with OCT were, however, slightly higher.

Conclusion

A good correlation was found between red blood cell velocity as measured with dual-beam bidirectional Doppler FD-OCT and red blood cell velocity assessed by the laser Doppler method. Dual-beam bidirectional Doppler FD-OCT is a promising approach for studying retinal blood velocities in vivo.  相似文献   

2.
The internal structure of plant tissues was visualized with optical coherence tomography (OCT). This noninvasive method is suitable for examining intact plants; it produces two-dimensional images of plant tissues at a penetration depth of 1–2 mm from the surface. The potential use of OCT was assessed on Tradescantia blossfeldiana Mild. Plant tissue images measuring 1.5 × 2 mm were obtained in vivo with a spatial resolution of 15 m. The radiation power incident on a sample was 0.5 mW. The acquisition of a two-dimensional image consisting of 200 × 200 pixels required 1–3 s. The OCT method can be used to visualize not only plant tissues and tissue boundaries but also the structure of individual cells.  相似文献   

3.

Background

This study determines ‘correlation constants’ between the gold standard histological measurement of retinal thickness and the newer spectral-domain optical coherence tomography (SD-OCT) technology in adult C57BL/6 mice.

Methods

Forty-eight eyes from adult mice underwent SD-OCT imaging and then were histologically prepared for frozen sectioning with H&E staining. Retinal thickness was measured via 10x light microscopy. SD-OCT images and histological sections were standardized to three anatomical sites relative to the optic nerve head (ONH) location. The ratios between SD-OCT to histological thickness for total retinal thickness (TRT) and six sublayers were defined as ‘correlation constants’.

Results

Mean (± SE) TRT for SD-OCT and histological sections was 210.95 µm (±1.09) and 219.58 µm (±2.67), respectively. The mean ‘correlation constant’ for TRT between the SD-OCT and histological sections was 0.96. The retinal thickness for all sublayers measured by SD-OCT vs. histology were also similar, the ‘correlation constant’ values ranged from 0.70 to 1.17. All SD-OCT and histological measurements demonstrated highly significant (p<0.01) strong positive correlations.

Conclusion

This study establishes conversion factors for the translation of ex vivo data into in vivo information; thus enhancing the applicability of SD-OCT in translational research.  相似文献   

4.
Computational models and experimental optical mapping of cardiac electrophysiology serve as powerful tools to investigate the underlying mechanisms of arrhythmias. Modeling can also aid the interpretation of optical mapping signals, which may have different characteristics with respect to the underlying electrophysiological signals they represent. However, despite the prevalence of atrial arrhythmias such as atrial fibrillation, models of optical electrical mapping incorporating realistic structure of the atria are lacking. Therefore, we developed image-based models of atrial tissue using structural information extracted from optical coherence tomography (OCT), which can provide volumetric tissue characteristics in high resolution. OCT volumetric data of four swine atrial tissue samples were used to develop models incorporating tissue geometry, tissue-specific myofiber orientation, and ablation lesion regions. We demonstrated the use of these models through electrophysiology and photon scattering simulations. Changes in transmural electrical conduction were observed with the inclusion of OCT-derived, depth-resolved fiber orientation. Additionally, the amplitude of optical mapping signals were not found to correspond with lesion transmurality because of lesion geometry and electrical propagation occurring beyond excitation light penetration. This work established a framework for the development of tissue-specific models of atrial tissue derived from OCT imaging data, which can be useful in future investigations of electrophysiology and optical mapping signals with respect to realistic atrial tissue structure.  相似文献   

5.
光学相干层析用于牙齿病变的检测   总被引:3,自引:0,他引:3  
阐述了适用于牙齿结构成像的光学相干层析成像(OCT)系统。系统光源中心波长为1 310 nm,成像分辨率10μm,在牙内成像深度2 mm,成像速度1幅/秒,系统信噪比100 dB。利用此OCT仪清晰检测到牙齿样品的牙釉质和牙本质,观察到牙釉质与牙本质的分界面以及正常牙齿牙釉质与龋齿牙齿牙釉质OCT图像的区别。进一步设计研制了适用于口腔内探测的小型OCT探头。  相似文献   

6.
Noncontact retinal blood flow measurements are performed with a Fourier domain optical coherence tomography (OCT) system using a circumpapillary double circular scan (CDCS) that scans around the optic nerve head at 3.40 mm and 3.75 mm diameters. The double concentric circles are performed 6 times consecutively over 2 sec. The CDCS scan is saved with Doppler shift information from which flow can be calculated. The standard clinical protocol calls for 3 CDCS scans made with the OCT beam passing through the superonasal edge of the pupil and 3 CDCS scan through the inferonal pupil. This double-angle protocol ensures that acceptable Doppler angle is obtained on each retinal branch vessel in at least 1 scan. The CDCS scan data, a 3-dimensional volumetric OCT scan of the optic disc scan, and a color photograph of the optic disc are used together to obtain retinal blood flow measurement on an eye. We have developed a blood flow measurement software called "Doppler optical coherence tomography of retinal circulation" (DOCTORC). This semi-automated software is used to measure total retinal blood flow, vessel cross section area, and average blood velocity. The flow of each vessel is calculated from the Doppler shift in the vessel cross-sectional area and the Doppler angle between the vessel and the OCT beam. Total retinal blood flow measurement is summed from the veins around the optic disc. The results obtained at our Doppler OCT reading center showed good reproducibility between graders and methods (<10%). Total retinal blood flow could be useful in the management of glaucoma, other retinal diseases, and retinal diseases. In glaucoma patients, OCT retinal blood flow measurement was highly correlated with visual field loss (R2>0.57 with visual field pattern deviation). Doppler OCT is a new method to perform rapid, noncontact, and repeatable measurement of total retinal blood flow using widely available Fourier-domain OCT instrumentation. This new technology may improve the practicality of making these measurements in clinical studies and routine clinical practice.  相似文献   

7.
光学相干层析成像(optical coherence tomography,OCT)技术是继X射线成像、核磁共振成像、超声成像等之后的一种新型的成像技术,其可光纤化的特点使得它易于医用电子内窥镜相结合。OCT内窥镜技术可实现对人体内部器官的高速率、高分辨率、无损伤、实时成像。主要介绍了OCT技术的种类、基本原理以及包括探测深度和纵向分辨率等的参数;简述了OCT内窥镜的发展历史以及最新成果,重点分析了光源对OCT内窥镜的影响。总结了OCT内窥镜的主要应用。  相似文献   

8.

This work presents the analysis of the growth kinetics of two syntheses of concave gold nanocubes with a mean size of 72 and 108 nm followed by the optical coherence tomography (OCT) technique by acquiring B-scan images each 5 s. In addition, ultra violet-visible (UV-Vis) spectra and mean size from dynamic light scattering (DLS) were acquired during nanoparticle growth to generate kinetic plots in order to corroborate the OCT results. Kinetic plots from OCT images were obtained by plotting contrast enhancement of B-scan images as function of time. Fitting parameters values given by using the classical Kolmogorov-Johnson-Mehl-Avrami (KJMA) equation show that the growth rate parameter k is higher for small cubes than for large ones, and that the Avrami exponent n associated to the growth kinetics of concave nanocubes is close to 2 for both syntheses. The results of UV-Vis spectroscopy and DLS confirm that OCT is a viable technique to provide information about nanoparticle growth kinetics. Moreover, to our knowledge, this is the first time that OCT technique is used to follow nanoparticle growth kinetics.

  相似文献   

9.
Both the clinical diagnosis and fundamental investigation of major ocular diseases greatly benefit from various non-invasive ophthalmic imaging technologies. Existing retinal imaging modalities, such as fundus photography1, confocal scanning laser ophthalmoscopy (cSLO)2, and optical coherence tomography (OCT)3, have significant contributions in monitoring disease onsets and progressions, and developing new therapeutic strategies. However, they predominantly rely on the back-reflected photons from the retina. As a consequence, the optical absorption properties of the retina, which are usually strongly associated with retinal pathophysiology status, are inaccessible by the traditional imaging technologies.Photoacoustic ophthalmoscopy (PAOM) is an emerging retinal imaging modality that permits the detection of the optical absorption contrasts in the eye with a high sensitivity4-7 . In PAOM nanosecond laser pulses are delivered through the pupil and scanned across the posterior eye to induce photoacoustic (PA) signals, which are detected by an unfocused ultrasonic transducer attached to the eyelid. Because of the strong optical absorption of hemoglobin and melanin, PAOM is capable of non-invasively imaging the retinal and choroidal vasculatures, and the retinal pigment epithelium (RPE) melanin at high contrasts 6,7. More importantly, based on the well-developed spectroscopic photoacoustic imaging5,8 , PAOM has the potential to map the hemoglobin oxygen saturation in retinal vessels, which can be critical in studying the physiology and pathology of several blinding diseases 9 such as diabetic retinopathy and neovascular age-related macular degeneration.Moreover, being the only existing optical-absorption-based ophthalmic imaging modality, PAOM can be integrated with well-established clinical ophthalmic imaging techniques to achieve more comprehensive anatomic and functional evaluations of the eye based on multiple optical contrasts6,10 . In this work, we integrate PAOM and spectral-domain OCT (SD-OCT) for simultaneously in vivo retinal imaging of rat, where both optical absorption and scattering properties of the retina are revealed. The system configuration, system alignment and imaging acquisition are presented.  相似文献   

10.
介绍了分子对比剂在光学相干层析成像(optical coherence tom ography,OCT)技术中的研究现状,概述了迄今出现的几种不同的光学相干层析分子成像方法(m olecu lar contrast OCT,简称为MCOCT),讨论了MCOCT的几个重要的实际问题:对比剂的选择范围、激发光强的限制、各种方法灵敏度比较以及MCOCT应用于临床与生物学领域需要考虑的因素。  相似文献   

11.
Comparative analysis of two optical methods—optical coherence tomography (OCT) and optical coherence microscopy (OCM)—was made for vital visualization of plant tissues in tomato (Lycopersicon esculentum Mill), spiderwort (Tradescantia pallida (Rose) D. Hunt), orach (Atriplex sp.), and leaves and seeds of medium starwort (Stellaria media L.). The obtained OCT- and OCM-images allowed the morphological and functional state of plant tissues to be assessed in vivo. A higher spatial resolution of the OCM method, as compared to OCT method, allowed plant morphological structures to be identified with greater confidence. The morphological and functional state of tissues can be monitored with a time resolution of 1–4 s in intact plants, without removing them from the habitat.__________Translated from Fiziologiya Rastenii, Vol. 52, No. 4, 2005, pp. 628–634.Original Russian Text Copyright © 2005 by Kutis, Sapozhnikova, Kuranov, Kamenskii.  相似文献   

12.
光学相干层析成像技术用于裸鼠皮肤霉菌感染研究   总被引:1,自引:0,他引:1  
利用中心波长为850 nm的宽带光源SLD实现了纵向分辨率为8μm的光学相干层析成像系统。系统采用傅里叶域光学延迟线实现了深度扫描速度为160 mm/s,成像深度为3 mm。获得了裸鼠皮肤霉菌感染部位和健康皮肤的光学相干层析(optical coherence tom ography,OCT)图像,皮肤病变前后的内部结构信息清晰可见。  相似文献   

13.
将谱域光学相干层析技术(Spectral-domain Optical Coherence Tomography,SD-OCT)应用于细胞膜厚的动态检测,引入了光谱干涉测量方法,通过对干涉光谱信号进行离散傅里叶变换得到表示物体深度位置信息的光程差信号。搭建了一套SD-OCT测量系统并设计了专门用于细胞检测的样品平台,检测精度达到μm量级,信噪比达70 db,是一种快速、实时、非接触的细胞分子膜厚动态检测技术。  相似文献   

14.
For the first time, we present co-registered autofluorescence imaging and optical coherence tomography (AF/OCT) of excised human palatine tonsils to evaluate the capabilities of OCT to visualize tonsil tissue components. Despite limited penetration depth, OCT can provide detailed structural information about tonsil tissue with much higher resolution than that of computed tomography, magnetic resonance imaging, and Ultrasound. Different tonsil tissue components such as epithelium, dense connective tissue, lymphoid nodules, and crypts can be visualized by OCT. The co-registered AF imaging can provide matching biochemical information. AF/OCT scans may provide a non-invasive tool for detecting tonsillar cancers and for studying the natural history of their development.  相似文献   

15.
目的:探讨活体组织液体含量的改变对OCT成像的影响,以期提高OCT在诊断组织病理性质方面的能力。方法:实验中复制脱水大鼠病理模型,应用光学相干层析成像设备,进行大鼠舌浅表组织在体显微成像检测,并对图像中组织的信号衰减特性进行量化分析。结果:正常对照组大鼠体重明显增加,病理模型组显著下降,病理模型组于脱水3天和5天后组织的平均OCT信号衰减系数明显高于正常对照组(P<0.01),且5天较3天的病理模型组组织的信号衰减系数变化尤其显著(P<0.01)。结论:改变组织含液量,可显著改变OCT成像效果,且通过对OCT图像中信号的衰减系数分析,可获得组织细微的散射变化,从而有望提高OCT技术在组织性质方面的诊断能力。  相似文献   

16.
传统光学相干断层成像可实现无损伤在体检测,具有较高的分辨率和灵敏度。获取生物组织的双折射信息可望是其应用之一。本文用传统光学相干断层成像系统以动物模型对关节软骨进行了研究,对软骨组织的传统光学相干断层图像的层结构随脱水和机械作用的变化进行了分析。结果表明,传统光学相干断层成像系统在一定程度上可用于监测由其胶原质纤维排列决定的软骨组织的双折射和密度。  相似文献   

17.
Understanding the nature and mechanism of congenital defects of the different organ systems in humans has heavily relied on the analysis of the corresponding mutant phenotypes in rodent models. Optical Coherence Tomography (OCT) has recently emerged as a powerful tool to study early embryonic development. This non-invasive optical methodology does not require labeling and allows visualization of embryonic tissues with single cell resolution. Here, we will discuss how OCT can be applied for structural imaging of early mouse and rat embryos in static culture, cardiodynamic and blood flow analysis, and in utero embryonic imaging at later stages of gestation, demonstrating how OCT can be used to assess structural and functional birth defects in mammalian models.  相似文献   

18.
本研究利用光学相干层析术OCT对泼尼松龙诱导的斑马鱼骨质疏松模型进行活体成像,并结合电镜能谱技术定量分析斑马鱼模型骨质的钙磷元素含量及分布情况,共同探讨OCT方法在基于斑马鱼模型开展的骨质疏松研究中的使用价值。选取40条3月龄野生型斑马鱼暴露于50μmol/L泼尼松龙溶液和含0. 5%DMSO的溶液中(对照组),28. 5℃下培养,分别于第5、10、20天取出浸药组和对照组进行OCT活体成像,比较两者光散射特征。在每个时间点的成像之后,将浸药组的5条斑马鱼处死,然后取颅骨进行元素含量电镜扫描能谱分析。本研究利用50μmol/L泼尼松龙溶液培养斑马鱼至第20天,成功构建了斑马鱼骨质疏松模型。与对照组相比,模型组活体OCT成像显示骨组织光散射减弱,光子量明显减少,呈不均匀分布。能谱元素检查结果说明颅骨内所含钙、磷比例明显下降,证实骨质疏松发生,骨量减少。OCT成像方法在对斑马鱼骨质疏松模型进行活体、实时、无创等研究方面具有重要价值,本试验也为骨质疏松疾病的研究和药物筛选等方面提供了新的有效的方法。  相似文献   

19.
20.
Optical coherence tomography (OCT) has revolutionises the diagnosis of retinal disease based on the detection of microscopic rather than subcellular changes in retinal anatomy. However, currently the technique is limited to the detection of microscopic rather than subcellular changes in retinal anatomy. However, coherence based imaging is extremely sensitive to both changes in optical contrast and cellular events at the micrometer scale, and can generate subtle changes in the spectral content of the OCT image. Here we test the hypothesis that OCT image speckle (image texture) contains information regarding otherwise unresolvable features such as organelle changes arising in the early stages of neuronal degeneration. Using ultrahigh resolution (UHR) OCT imaging at 800 nm (spectral width 140 nm) we developed a robust method of OCT image analyses, based on spatial wavelet and texture-based parameterisation of the image speckle pattern. For the first time we show that this approach allows the non-invasive detection and quantification of early apoptotic changes in neurons within 30 min of neuronal trauma sufficient to result in apoptosis. We show a positive correlation between immunofluorescent labelling of mitochondria (a potential source of changes in cellular optical contrast) with changes in the texture of the OCT images of cultured neurons. Moreover, similar changes in optical contrast were also seen in the retinal ganglion cell- inner plexiform layer in retinal explants following optic nerve transection. The optical clarity of the explants was maintained throughout in the absence of histologically detectable change. Our data suggest that UHR OCT can be used for the non-invasive quantitative assessment of neuronal health, with a particular application to the assessment of early retinal disease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号