首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Image segmentation of retinal blood vessels is a process that can help to predict and diagnose cardiovascular related diseases, such as hypertension and diabetes, which are known to affect the retinal blood vessels’ appearance. This work proposes an unsupervised method for the segmentation of retinal vessels images using a combined matched filter, Frangi’s filter and Gabor Wavelet filter to enhance the images. The combination of these three filters in order to improve the segmentation is the main motivation of this work. We investigate two approaches to perform the filter combination: weighted mean and median ranking. Segmentation methods are tested after the vessel enhancement. Enhanced images with median ranking are segmented using a simple threshold criterion. Two segmentation procedures are applied when considering enhanced retinal images using the weighted mean approach. The first method is based on deformable models and the second uses fuzzy C-means for the image segmentation. The procedure is evaluated using two public image databases, Drive and Stare. The experimental results demonstrate that the proposed methods perform well for vessel segmentation in comparison with state-of-the-art methods.  相似文献   

2.
Diabetic Retinopathy (DR) harm retinal blood vessels in the eye causing visual deficiency. The appearance and structure of blood vessels in retinal images play an essential part in the diagnoses of an eye sicknesses. We proposed a less computational unsupervised automated technique with promising results for detection of retinal vasculature by using morphological hessian based approach and region based Otsu thresholding. Contrast Limited Adaptive Histogram Equalization (CLAHE) and morphological filters have been used for enhancement and to remove low frequency noise or geometrical objects, respectively. The hessian matrix and eigenvalues approach used has been in a modified form at two different scales to extract wide and thin vessel enhanced images separately. Otsu thresholding has been further applied in a novel way to classify vessel and non-vessel pixels from both enhanced images. Finally, postprocessing steps has been used to eliminate the unwanted region/segment, non-vessel pixels, disease abnormalities and noise, to obtain a final segmented image. The proposed technique has been analyzed on the openly accessible DRIVE (Digital Retinal Images for Vessel Extraction) and STARE (STructured Analysis of the REtina) databases along with the ground truth data that has been precisely marked by the experts.  相似文献   

3.
Electroporation-based treatments rely on increasing the permeability of the cell membrane by high voltage electric pulses applied to tissue via electrodes. To ensure that the whole tumor is covered with sufficiently high electric field, accurate numerical models are built based on individual patient anatomy. Extraction of patient''s anatomy through segmentation of medical images inevitably produces some errors. In order to ensure the robustness of treatment planning, it is necessary to evaluate the potential effect of such errors on the electric field distribution. In this work we focus on determining the effect of errors in automatic segmentation of hepatic vessels on the electric field distribution in electroporation-based treatments in the liver. First, a numerical analysis was performed on a simple ''sphere and cylinder'' model for tumors and vessels of different sizes and relative positions. Second, an analysis of two models extracted from medical images of real patients in which we introduced variations of an error of the automatic vessel segmentation method was performed. The results obtained from a simple model indicate that ignoring the vessels when calculating the electric field distribution can cause insufficient coverage of the tumor with electric fields. Results of this study indicate that this effect happens for small (10 mm) and medium-sized (30 mm) tumors, especially in the absence of a central electrode inserted in the tumor. The results obtained from the real-case models also show higher negative impact of automatic vessel segmentation errors on the electric field distribution when the central electrode is absent. However, the average error of the automatic vessel segmentation did not have an impact on the electric field distribution if the central electrode was present. This suggests the algorithm is robust enough to be used in creating a model for treatment parameter optimization, but with a central electrode.  相似文献   

4.
Liver segmentation from abdominal computed tomography (CT) volumes is extremely important for computer-aided liver disease diagnosis and surgical planning of liver transplantation. Due to ambiguous edges, tissue adhesion, and variation in liver intensity and shape across patients, accurate liver segmentation is a challenging task. In this paper, we present an efficient semi-automatic method using intensity, local context, and spatial correlation of adjacent slices for the segmentation of healthy liver regions in CT volumes. An intensity model is combined with a principal component analysis (PCA) based appearance model to exclude complex background and highlight liver region. They are then integrated with location information from neighboring slices into graph cuts to segment the liver in each slice automatically. Finally, a boundary refinement method based on bottleneck detection is used to increase the segmentation accuracy. Our method does not require heavy training process or statistical model construction, and is capable of dealing with complicated shape and intensity variations. We apply the proposed method on XHCSU14 and SLIVER07 databases, and evaluate it by MICCAI criteria and Dice similarity coefficient. Experimental results show our method outperforms several existing methods on liver segmentation.  相似文献   

5.
Vessel segmentation in retinal fundus images is a preliminary step to clinical diagnosis for some systemic diseases and some eye diseases. The performances of existing methods for segmenting small vessels which are usually of more importance than the main vessels in a clinical diagnosis are not satisfactory in clinical use. In this paper, we present a method for both main and peripheral vessel segmentation. A local gray-level change enhancement algorithm called gray-voting is used to enhance the small vessels, while a two-dimensional Gabor wavelet is used to extract the main vessels. We fuse the gray-voting results with the 2D-Gabor filter results as pre-processing outcome. A Gaussian mixture model is then used to extract vessel clusters from the pre-processing outcome, while small vessels fragments are obtained using another gray-voting process, which complements the vessel cluster extraction already performed. At the last step, we eliminate the fragments that do not belong to the vessels based on the shape of the fragments. We evaluated the approach with two publicly available DRIVE (Staal et al., 2004) and STARE (Hoover et at., 2000) datasets with manually segmented results. For the STARE dataset, when using the second manually segmented results which include much more small vessels than the first manually segmented results as the “gold standard,” this approach achieved an average sensitivity, accuracy and specificity of 65.0%, 92.1% and 97.0%, respectively. The sensitivities of this approach were much higher than those of the other existing methods, with comparable specificities; these results thus demonstrated that this approach was sensitive to detection of small vessels.  相似文献   

6.
Positron emission tomography (PET) images have been incorporated into the radiotherapy process as a powerful tool to assist in the contouring of lesions, leading to the emergence of a broad spectrum of automatic segmentation schemes for PET images (PET-AS). However, not all proposed PET-AS algorithms take into consideration the previous steps of image preparation. PET image noise has been shown to be one of the most relevant affecting factors in segmentation tasks. This study demonstrates a nonlinear filtering method based on spatially adaptive wavelet shrinkage using three-dimensional context modelling that considers the correlation of each voxel with its neighbours. Using this noise reduction method, excellent edge conservation properties are obtained. To evaluate the influence in the segmentation schemes of this filter, it was compared with a set of Gaussian filters (the most conventional) and with two previously optimised edge-preserving filters. Five segmentation schemes were used (most commonly implemented in commercial software): fixed thresholding, adaptive thresholding, watershed, adaptive region growing and affinity propagation clustering. Segmentation results were evaluated using the Dice similarity coefficient and classification error. A simple metric was also included to improve the characterisation of the filters used for induced blurring evaluation, based on the measurement of the average edge width. The proposed noise reduction procedure improves the results of segmentation throughout the performed settings and was shown to be more stable in low-contrast and high-noise conditions. Thus, the capacity of the segmentation method is reinforced by the denoising plan used.  相似文献   

7.
《IRBM》2020,41(6):304-315
Vascular segmentation is often required in medical image analysis for various imaging modalities. Despite the rich literature in the field, the proposed methods need most of the time adaptation to the particular investigation and may sometimes lack the desired accuracy in terms of true positive and false positive detection rate. This paper proposes a general method for vascular segmentation based on locally connected filtering applied in a multiresolution scheme. The filtering scheme performs progressive detection and removal of the vessels from the image relief at each resolution level, by combining directional 2D-3D locally connected filters (LCF). An important property of the LCF is that it preserves (positive contrasted) structures in the image if they are topologically connected with other similar structures in their local environment. Vessels, which appear as curvilinear structures, can be filtered out by an appropriate LCF set-up which will minimally affect sheet-like structures. The implementation in a multiresolution framework allows dealing with different vessel sizes. The outcome of the proposed approach is illustrated on several image modalities including lung, liver and coronary arteries. It is shown that besides preserving high accuracy in detecting small vessels, the proposed technique is less sensitive with respect to noise and the presence of pathologies of positive-contrast appearance on the images. The detection accuracy is compared with a previously developed approach on the 20 patient database from the VESSEL12 challenge.  相似文献   

8.
As the only vascular tissue that can be directly viewed in vivo, retinal vessels are medically important in assisting the diagnosis of ocular and cardiovascular diseases. They generally appear as different morphologies and uneven thickness in fundus images. Therefore, the single-scale segmentation method may fail to capture abundant morphological features, suffering from the deterioration in vessel segmentation, especially for tiny vessels. To alleviate this issue, we propose a multi-scale channel fusion and spatial activation network (MCFSA-Net) for retinal vessel segmentation with emphasis on tiny ones. Specifically, the Hybrid Convolution-DropBlock (HC-Drop) is first used to extract deep features of vessels and construct multi-scale feature maps by progressive down-sampling. Then, the Channel Cooperative Attention Fusion (CCAF) module is designed to handle different morphological vessels in a multi-scale manner. Finally, the Global Spatial Activation (GSA) module is introduced to aggregate global feature information for improving the attention on tiny vessels in the spatial domain and realizing effective segmentation for them. Experiments are carried out on three datasets including DRIVE, CHASE_DB1, and STARE. Our retinal vessel segmentation method achieves Accuracy of 96.95%, 97.57%, and 97.83%, and F1 score of 82.67%, 81.82%, and 82.95% in the above datasets, respectively. Qualitative and quantitative analysis show that the proposed method outperforms current advanced vessel segmentation methods, especially for tiny vessels.  相似文献   

9.
AimThis study evaluated a convolutional neural network (CNN) for automatically delineating the liver on contrast-enhanced or non-contrast-enhanced CT, making comparisons with a commercial automated technique (MIM Maestro®).BackgroundIntensity-modulated radiation therapy requires careful labor-intensive planning involving delineation of the target and organs on CT or MR images to ensure delivery of the effective dose to the target while avoiding organs at risk.Materials and MethodsContrast-enhanced planning CT images from 101 pancreatic cancer cases and accompanying mask images showing manually-delineated liver contours were used to train the CNN to segment the liver. The trained CNN then performed liver segmentation on a further 20 contrast-enhanced and 15 non-contrastenhanced CT image sets, producing three-dimensional mask images of the liver.ResultsFor both contrast-enhanced and non-contrast-enhanced images, the mean Dice similarity coefficients between CNN segmentations and ground-truth manual segmentations were significantly higher than those between ground-truth and MIM Maestro software (p < 0.001). Although mean CT values of the liver were higher on contrast-enhanced than on non-contrast-enhanced CT, there were no significant differences in the Hausdorff distances of the CNN segmentations, indicating that the CNN could successfully segment the liver on both image types, despite being trained only on contrast-enhanced images.ConclusionsOur results suggest that a CNN can perform highly accurate automated delineation of the liver on CT images, irrespective of whether the CT images are contrast-enhanced or not.  相似文献   

10.
Tang J  Guo S  Sun Q  Deng Y  Zhou D 《BMC genomics》2010,11(Z2):S9

Background

Ultrasound imaging technology has wide applications in cattle reproduction and has been used to monitor individual follicles and determine the patterns of follicular development. However, the speckles in ultrasound images affect the post-processing, such as follicle segmentation and finally affect the measurement of the follicles. In order to reduce the effect of speckles, a bilateral filter is developed in this paper.

Results

We develop a new bilateral filter for speckle reduction in ultrasound images for follicle segmentation and measurement. Different from the previous bilateral filters, the proposed bilateral filter uses normalized difference in the computation of the Gaussian intensity difference. We also present the results of follicle segmentation after speckle reduction. Experimental results on both synthetic images and real ultrasound images demonstrate the effectiveness of the proposed filter.

Conclusions

Compared with the previous bilateral filters, the proposed bilateral filter can reduce speckles in both high-intensity regions and low intensity regions in ultrasound images. The segmentation of the follicles in the speckle reduced images by the proposed method has higher performance than the segmentation in the original ultrasound image, and the images filtered by Gaussian filter, the conventional bilateral filter respectively.
  相似文献   

11.
In this paper, we demonstrate a comprehensive method for segmenting the retinal vasculature in camera images of the fundus. This is of interest in the area of diagnostics for eye diseases that affect the blood vessels in the eye. In a departure from other state-of-the-art methods, vessels are first pre-grouped together with graph partitioning, using a spectral clustering technique based on morphological features. Local curvature is estimated over the whole image using eigenvalues of Hessian matrix in order to enhance the vessels, which appear as ridges in images of the retina. The result is combined with a binarized image, obtained using a threshold that maximizes entropy, to extract the retinal vessels from the background. Speckle type noise is reduced by applying a connectivity constraint on the extracted curvature based enhanced image. This constraint is varied over the image according to each region''s predominant blood vessel size. The resultant image exhibits the central light reflex of retinal arteries and veins, which prevents the segmentation of whole vessels. To address this, the earlier entropy-based binarization technique is repeated on the original image, but crucially, with a different threshold to incorporate the central reflex vessels. The final segmentation is achieved by combining the segmented vessels with and without central light reflex. We carry out our approach on DRIVE and REVIEW, two publicly available collections of retinal images for research purposes. The obtained results are compared with state-of-the-art methods in the literature using metrics such as sensitivity (true positive rate), selectivity (false positive rate) and accuracy rates for the DRIVE images and measured vessel widths for the REVIEW images. Our approach out-performs the methods in the literature.  相似文献   

12.
Individualized modeling and simulation of blood flow mechanics find applications in both animal research and patient care. Individual animal or patient models for blood vessel mechanics are based on combining measured vascular geometry with a fluid structure model coupling formulations describing dynamics of the fluid and mechanics of the wall. For example, one-dimensional fluid flow modeling requires a constitutive law relating vessel cross-sectional deformation to pressure in the lumen. To investigate means of identifying appropriate constitutive relationships, an automated segmentation algorithm was applied to micro-computerized tomography images from a mouse lung obtained at four different static pressures to identify the static pressure–radius relationship for four generations of vessels in the pulmonary arterial network. A shape-fitting function was parameterized for each vessel in the network to characterize the nonlinear and heterogeneous nature of vessel distensibility in the pulmonary arteries. These data on morphometric and mechanical properties were used to simulate pressure and flow velocity propagation in the network using one-dimensional representations of fluid and vessel wall mechanics. Moreover, wave intensity analysis was used to study effects of wall mechanics on generation and propagation of pressure wave reflections. Simulations were conducted to investigate the role of linear versus nonlinear formulations of wall elasticity and homogeneous versus heterogeneous treatments of vessel wall properties. Accounting for heterogeneity, by parameterizing the pressure/distention equation of state individually for each vessel segment, was found to have little effect on the predicted pressure profiles and wave propagation compared to a homogeneous parameterization based on average behavior. However, substantially different results were obtained using a linear elastic thin-shell model than were obtained using a nonlinear model that has a more physiologically realistic pressure versus radius relationship.  相似文献   

13.
BACKGROUND: Epiluminescence microscopy (ELM) is a noninvasive clinical tool recently developed for the diagnosis of pigmented skin lesions (PSLs), with the aim of improving melanoma screening strategies. However, the complexity of the ELM grading protocol means that considerable expertise is required for differential diagnosis. In this paper we propose a computer-based tool able to screen ELM images of PSLs in order to aid clinicians in the detection of lesion patterns useful for differential diagnosis. METHODS: The method proposed is based on the supervised classification of pixels of digitized ELM images, and leads to the construction of classes of pixels used for image segmentation. This process has two major phases, i.e., a learning phase, where several hundred pixels are used in order to train and validate a classification model, and an application step, which consists of a massive classification of billions of pixels (i.e., the full image) by means of the rules obtained in the first phase. RESULTS: Our results show that the proposed method is suitable for lesion-from-background extraction, for complete image segmentation into several typical diagnostic patterns, and for artifact rejection. Hence, our prototype has the potential to assist in distinguishing lesion patterns which are associated with diagnostic information such as diffuse pigmentation, dark globules (black dots and brown globules), and the gray-blue veil. CONCLUSIONS: The system proposed in this paper can be considered as a tool to assist in PSL diagnosis.  相似文献   

14.
IntroductionMedical images are usually affected by biological and physical artifacts or noise, which reduces image quality and hence poses difficulties in visual analysis, interpretation and thus requires higher doses and increased radiographs repetition rate.ObjectivesThis study aims at assessing image quality during CT abdomen and brain examinations using filtering techniques as well as estimating the radiogenic risk associated with CT abdomen and brain examinations.Materials and MethodsThe data were collected from the Radiology Department at Royal Care International (RCI) Hospital, Khartoum, Sudan. The study included 100 abdominal CT images and 100 brain CT images selected from adult patients. Filters applied are namely: Mean filter, Gaussian filter, Median filter and Minimum filter. In this study, image quality after denoising is measured based on the Mean Squared Error (MSE), Peak Signal-to-Noise Ratio (PSNR), and the Structural Similarity Index Metric (SSIM).ResultsThe results show that the images quality parameters become higher after applications of filters. Median filter showed improved image quality as interpreted by the measured parameters: PSNR and SSIM, and it is thus considered as a better filter for removing the noise from all other applied filters.DiscussionThe noise removed by the different filters applied to the CT images resulted in enhancing high quality images thereby effectively revealing the important details of the images without increasing the patients’ risks from higher doses.ConclusionsFiltering and image reconstruction techniques not only reduce the dose and thus the radiation risks, but also enhances high quality imaging which allows better diagnosis.  相似文献   

15.
The fine periodic growth patterns on shell surfaces have been widely used for studies in the ecology and evolution of scallops. Modern X‐ray CT scanners and digital cameras can provide high‐resolution image data that contain abundant information such as the shell formation rate, ontogenetic age, and life span of shellfish organisms. We introduced a novel multiscale image processing method based on matched filters with Gaussian kernels and partial differential equation (PDE) multiscale hierarchical decomposition to segment the small tubular and periodic structures in scallop shell images. The periodic patterns of structures (consisting of bifurcation points, crossover points of the rings and ribs, and the connected lines) could be found by our Space‐based Depth‐First Search (SDFS) algorithm. We created a MATLAB package to implement our method of periodic pattern extraction and pattern matching on the CT and digital scallop images available in this study. The results confirmed the hypothesis that the shell cyclic structure patterns encompass genetically specific information that can be used as an effective invariable biomarker for biological individual recognition. The package is available with a quick‐start guide and includes three examples: http://mgb.ouc.edu.cn/novegene/html/code.php .  相似文献   

16.
Our application concerns the automated detection of vessels in retinal images to improve understanding of the disease mechanism, diagnosis and treatment of retinal and a number of systemic diseases. We propose a new framework for segmenting retinal vasculatures with much improved accuracy and efficiency. The proposed framework consists of three technical components: Retinex-based image inhomogeneity correction, local phase-based vessel enhancement and graph cut-based active contour segmentation. These procedures are applied in the following order. Underpinned by the Retinex theory, the inhomogeneity correction step aims to address challenges presented by the image intensity inhomogeneities, and the relatively low contrast of thin vessels compared to the background. The local phase enhancement technique is employed to enhance vessels for its superiority in preserving the vessel edges. The graph cut-based active contour method is used for its efficiency and effectiveness in segmenting the vessels from the enhanced images using the local phase filter. We have demonstrated its performance by applying it to four public retinal image datasets (3 datasets of color fundus photography and 1 of fluorescein angiography). Statistical analysis demonstrates that each component of the framework can provide the level of performance expected. The proposed framework is compared with widely used unsupervised and supervised methods, showing that the overall framework outperforms its competitors. For example, the achieved sensitivity (0:744), specificity (0:978) and accuracy (0:953) for the DRIVE dataset are very close to those of the manual annotations obtained by the second observer.  相似文献   

17.
The retinal vessel width relationship at vessel branch points in fundus images is an important biomarker of retinal and systemic disease. We propose a fully automatic method to measure the vessel widths at branch points in fundus images. The method is a graph-based method, in which a graph construction method based on electric field theory is applied which specifically deals with complex branching patterns. The vessel centerline image is used as the initial segmentation of the graph. Branching points are detected on the vessel centerline image using a set of detection kernels. Crossing points are distinguished from branch points and excluded. The electric field based graph method is applied to construct the graph. This method is inspired by the non-intersecting force lines in an electric field. At last, the method is further improved to give a consistent vessel width measurement for the whole vessel tree. The algorithm was validated on 100 artery branchings and 100 vein branchings selected from 50 fundus images by comparing with vessel width measurements from two human experts.  相似文献   

18.
《IRBM》2022,43(6):561-572
ObjectivesCerebrovascular disease is a serious threat to human health. Because of its high mortality and disability rate, early diagnosis and prevention are very important. The performance of existing cerebrovascular segmentation methods based on deep learning depends on the integrity of labels. However, manual labels are usually of low quality and poor connectivity at small blood vessels, which directly affects the cerebrovascular segmentation results.Material and methodIn this paper, we propose a new segmentation network to segment cerebral vessels from MRA images by using sparse labels. The long-distance dependence between vascular structures is captured by the global vascular context module, and the topology is constrained by the hybrid loss function to segment the cerebral vessels with good connectivity.ResultExperiments show that our method performed with a sensitivity, precision, dice similarity coefficient, intersection over union and centerline dice similarity coefficient of 61.24%, 75.58%, 67.66%, 51.13% and 83.79% respectively.ConclusionThe obtained results reveal that the proposed cerebrovascular segmentation network has better segmentation performance for cerebrovascular segmentation under sparse labels, and can suppress the noise of background to a certain extent.  相似文献   

19.
IntroductionA mathematical 3D model of an existing computed tomography (CT) scanner was created and used in the EGSnrc-based BEAMnrc and egs_cbct Monte Carlo codes. Simulated transmission dose profiles of a RMI-465 phantom were analysed to verify Hounsfield numbers against measured data obtained from the CT scanner.Methods and materialsThe modelled CT unit is based on the design of a Toshiba Aquilion 16 LB CT scanner. As a first step, BEAMnrc simulated the X-ray tube, filters, and secondary collimation to obtain phase space data of the X-ray beam. A bowtie filter was included to create a more uniform beam intensity and to remove the beam hardening effects. In a second step the Interactive Data Language (IDL) code was used to build an EGSPHANT file that contained the RMI phantom which was used in egs_cbct simulations. After simulation a series of profiles were sampled from the detector model and the Feldkamp-Davis-Kress (FDK) algorithm was used to reconstruct transversal images. The results were tested against measured data obtained from CT scans.ResultsThe egs_cbct code can be used for the simulation of a fan beam CT unit. The calculated bowtie filter ensured a uniform flux on the detectors. Good correlation between measured and simulated CT numbers was obtained.ConclusionsIn principle, Monte Carlo codes such as egs_cbct can model a fan beam CT unit. After reconstruction, the images contained Hounsfield values comparable to measured data.  相似文献   

20.
In the next future, transcatheter aortic valve implantation could represent a minimally invasive option in case of bioprosthesis failure for patients at high surgical risk. CT based preoperative planning of this procedure could be useful to optimize valve-in-valve implantation. In this context, bioprosthesis 3D analysis seems to be necessary, particularly for leaflets. The goal of this study was to propose different methods to segment and characterize a degenerated bioprosthesis using standard preoperative CT scan images in order to map structural injury of bioprosthesis and, ultimately, to plan the best positioning for valve-in-valve implantation. We report our preliminary results on segmentation of a degenerated bioprosthesis in aortic position. Three different methods have been tested and all allowed obtaining segmentation of the different bioprosthesis components. Results were compared by means of quantitative criteria. Explanted bioprosthesis CT images were used as reference. Semi-automatic segmentation seems to provide an interesting approach for the morphological characterization of degenerated bioprosthesis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号