首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Simultaneous, hybrid MR-PET is expected to improve PET image resolution in the plane perpendicular to the static magnetic field of the scanner. Previous papers have reported this either by simulation or experiment with simple sources and detector arrangements. Here, we extend those studies using a realistic brain phantom in a recently installed MR-PET system comprising a 9.4 T MRI-scanner and an APD-based BrainPET insert in the magnet bore. Point and line sources and a 3D brain phantom were filled with 18F (low-energy positron emitter), 68Ga (medium energy positron emitter) or 120I, a non-standard positron emitter (high positron energies of up to 4.6 MeV). Using the BrainPET insert, emission scans of the phantoms were recorded at different positions inside and outside the magnet bore such that the magnetic field was 0 T, 3 T, 7 T or 9.4 T. Brain phantom images, with the ‘grey matter’ compartment filled with 18F, showed no obvious resolution improvement with increasing field. This is confirmed by practically unchanged transaxial FWHM and ‘grey/white matter’ ratio values between at 0T and 9.4T. Field-dependent improvements in the resolution and contrast of transaxial PET images were clearly evident when the brain phantom was filled with 68Ga or 120I. The grey/white matter ratio increased by 7.3% and 16.3%, respectively. The greater reduction of the FWTM compared to FWHM in 68Ga or 120I line-spread images was in agreement with the improved contrast of 68Ga or 120I images. Notwithstanding elongations seen in the z-direction of 68Ga or 120I point source images acquired in foam, brain phantom images show no comparable extension. Our experimental study confirms that integrated MR-PET delivers improved PET image resolution and contrast for medium- and high-energy positron emitters even though the positron range is reduced only in directions perpendicular to the magnetic field.  相似文献   

2.
Our laboratory has developed PET detectors with depth-encoding accuracy of ∼2 mm based on finely pixelated crystals with a tapered geometry, readout at both ends with position-sensitive avalanche photodiodes (PSAPDs). These detectors are currently being used in our laboratory to build a one-ring high resolution PET scanner for mouse brain imaging studies. Due to the inactive areas around the PSAPDs, large gaps exist between the detector modules which can degrade the image spatial resolution obtained using analytical reconstruction with filtered backprojection (FBP). In this work, the Geant4-based GATE Monte Carlo package was used to assist in determining whether gantry rotation was necessary and to assess the expected spatial resolution of the system. The following factors were investigated: rotating vs. static gantry modes with and without compensation of missing data using the discrete cosine transform (DCT) method, two levels of depth-encoding, and positron annihilation effects for 18F. Our results indicate that while the static scanner produces poor quality FBP images with streak and ring artifacts, the image quality was greatly improved after compensation of missing data. The simulation indicates that the expected FWHM system spatial resolution is 0.70 ± 0.05 mm, which approaches the predicted limit of 0.5 mm FWHM due to positron range, photon non-colinearity and physical detector element size effects. We conclude that excellent reconstructed resolution without gantry rotation is possible even using FBP if the gaps are appropriately handled and that this design can approach the resolution limits set by positron annihilation physics.  相似文献   

3.
Human and small-animal positron emission tomography (PET) scanners with cylindrical geometry and conventional detectors exhibit a progressive reduction in radial spatial resolution with increasing radial distance from the geometric axis of the scanner. This "depth-of-interaction" (DOI) effect is sufficiently deleterious that many laboratories have devised novel schemes to reduce the magnitude of this effect and thereby yield PET images of greater quantitative accuracy. Here we examine experimentally the effects of a particular DOI correction method (dual-scintillator phoswich detectors with pulse shape discrimination) implemented in a small-animal PET scanner by comparing the same phantom and same mouse images with and without DOI correction. The results suggest that even this relatively coarse, two-level estimate of radial gamma ray interaction position significantly reduces the DOI parallax error. This study also confirms two less appreciated advantages of DOI correction: a reduction in radial distortion and radial source displacement as a source is moved toward the edge of the field of view and a resolution improvement detectable in the central field of view likely owing to improved spatial sampling.  相似文献   

4.
Results are presented from numerical simulations of an axisymmetric normal glow discharge in molecular hydrogen and molecular nitrogen in an axial magnetic field. The charged particle densities and averaged azimuthal rotation velocities of electrons and ions are studied as functions of the gas pressure in the range of 1–5 Torr, electric field strength in the range of 100–600 V/cm, and magnetic field in the range of 0.01–0.3 T. It is found that the axial magnetic field does not disturb the normal current density law.  相似文献   

5.
Results are presented from experimental studies of the implosion of twisted nested arrays in which the wires of the outer and inner arrays are twisted about the array axis in opposite directions (clockwise and counterclockwise). Experiments with twisted arrays were carried out at the Angara-5-1 facility at currents of up to 4 MA. The currents through the arrays were switched either simultaneously or the current pulse through the outer array was delayed by 10–15 ns with the help of an anode spark gap. It is shown that, in such arrays, the currents flow along the inclined wires and, accordingly, there are both the azimuthal and axial components of the discharge current. The process of plasma implosion in twisted arrays depends substantially on the value of the axial (longitudinal) magnetic field generated inside the array by the azimuthal currents. Two-dimensional simulations of the magnetic field in twisted nested arrays were performed in the (r, z) geometry with allowance for the skin effect in the discharge electrodes. It is shown that, depending on the geometry of the discharge electrodes, different configurations of the magnetic field can be implemented inside twisted nested arrays. The calculated magnetic configurations are compared with the results of measurements of the magnetic field inside such arrays. It is shown that the configuration of the axial magnetic field inside a twisted nested array depends substantially on the distribution of the azimuthal currents between the inner and outer arrays.  相似文献   

6.
This article describes a single ring version of the micro crystal element scanner (MiCES) and investigation of its spatial resolution imaging characteristics for mouse positron emission tomography (PET) imaging. This single ring version of the MiCES system, referred to as QuickPET II, consists of 18 MiCE detector modules mounted as a single ring in a vertical gantry. The system has a 5.76-cm transverse field of view and a 1.98-cm axial field of view. In addition to the scanner and data acquisition system, we have developed an iterative reconstruction that includes a model of the system's detector response function. Evaluation images of line sources and mice have been acquired. Using filtered backprojection, the resolution for a reconstructed line source has been measured at 1.2 mm full width at half maximum. F-18-2-fluoro-2-deoxyglucose mouse PET images are provided. The result shows that QuickPET II has the imaging characteristics to support high-resolution, static mouse PET studies using 18-F labeled compounds.  相似文献   

7.
In modern magnetic resonance imaging , both patients and health care workers are exposed to strong, non-uniform static magnetic fields inside and outside of the scanner, in which body movement may be able to induce electric currents in tissues which could be potentially harmful. This paper presents theoretical investigations into the spatial distribution of induced E-fields in a tissue-equivalent human model when moving at various positions around the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme. Three-dimensional field profiles from an actively shielded 4 T magnet system are used and the body model projected through the field profile with normalized velocity. The simulation shows that it is possible to induce E-fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The methodology presented herein can be extrapolated to very high field strengths for the evaluation of the effects of motion at a variety of field strengths and velocities.  相似文献   

8.
The aim of this work is to develop a remotely controlled manipulator to perform minimally invasive diagnostic and therapeutic interventions in the abdominal and thoracic cavities, with real-time magnetic resonance imaging (MRI) guidance inside clinical cylindrical MR scanners. The manipulator is composed of a three degree of freedom Cartesian motion system, which resides outside the gantry of the scanner, and serves as the holder and global positioner of a three degree of freedom arm which extends inside the gantry of the scanner At its distal end, the arm's end-effector can carry an interventional tool such as a biopsy needle, which can be advanced to a desired depth by means of a seventh degree of freedom. These seven degrees of freedom, provided by the entire assembly, offer extended manipulability to the device and a wide envelope of operation to the user, who can select a trajectory suitable for the procedure. The device is constructed of nonmagnetic and nonconductive fiberglass, and carbon fiber composite materials, to minimize artifacts and distortion on the MR images as well as eliminate effects on its operation from the high magnetic field and the fast switching magnetic field gradients used in MR imaging. A user interface was developed for man-in-the-loop control of the device using real-time MR images. The user interface fuses all sensor signals (MR and manipulator information) in a visualization, planning, and control command environment. Path planning is performed with graphical tools for setting the trajectory of insertion of the interventional tool using multislice and/or three dimensional MR images which are refreshed in real time. The device control is performed with an embedded computer which runs real-time control software. The manipulator compatibility with the MR environment and image-guided operation was tested on a 1.5 T MR scanner.  相似文献   

9.
Photoacoustic microscopy (PAM) can be classified as optical resolution (OR)‐PAM and acoustic resolution (AR)‐PAM depending on the type of resolution achieved. Using microelectromechanical systems (MEMS) scanner, high‐speed OR‐PAM system was developed earlier. Depth of imaging limits the use of OR‐PAM technology for many preclinical and clinical imaging applications. Here, we demonstrate the use of a high‐speed MEMS scanner for AR‐PAM imaging. Lateral resolution of 84 μm and an axial resolution of 27 μm with ~2.7 mm imaging depth was achieved using a 50 MHz transducer‐based AR‐PAM system. Use of a higher frequency transducer at 75 MHz has further improved the resolution characteristics of the system with a reduction in imaging depth and a lateral resolution of 53 μm and an axial resolution of 18 μm with ~1.8 mm imaging depth was achieved. Using the two‐axis MEMS scanner a 2 × 2 .5 mm2 area was imaged in 3 seconds. The capability of achieving acoustic resolution images using the MEMS scanner makes it beneficial for the development of high‐speed miniaturized systems for deeper tissue imaging.   相似文献   

10.
Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25–2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 μT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences. Bioelectromagnetics 18:67–76, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

11.
Positron emission tomography (PET) is an important imaging modality for clincial use. Conventionally, the PET scanner is generally built to provide a roomy enough transverse field-of-view (FOV) for imaging most adults’ torsos. However, in many cases, the region-of-interest (ROI) for imaging is usually a small area inside the human body. Therefore, to fulfill a PET system which provides an FOV comparable in size to the target ROI seems appealing and more cost effective. Meanwhile, such a PET system has the potential for portable or bedside application with the reduced system size. In this work, we have investigated the feasibility of using dual-headed panel-detectors to build an ROI-focused PET scanner. A novel windowed list-mode ordered subset expectation maximization method was developed to perform the ROI image reconstruction. With this method, the ROI of the object can be reconstructed from the coincidences whose position determined by time-of-flight (TOF) measurements was inside the ROI. Monte Carlo simulation demonstrates the feasibility of detecting lesions not less than 1 cm in diameter, with a 300 ps full width at half maximum timing resolution. As a critical system performance, the impact of TOF information on image quality has been studied and the required TOF capability was assessed. With enhanced timing resolution, the distortions and artifacts were reduced effectively. The further improved TOF capability also shows a noticeable improvement of detection performance for low uptake lesions, as well as the recovery speed of lesion contrast, which is of practical significance in the lesion detection task.  相似文献   

12.
Theoretical study of the propagation of a packet of surface electromagnetic surface waves with a zero axial wavenumber in a circular-cross-section cylindrical metal waveguide within the frequency range that is higher than upper hybrid resonance is carried out. The waveguide is partially filled by plasma and immersed into axial magnetic field. The cross section of the plasma column is assumed to differ from circular shape. The effect of this shape on the dispersion properties of azimuthal surface modes is investigated by the method of successive approximations. The fields of the waves and their eigenfrequencies are determined up to terms of the second order in the deviation of the plasma cross section shape from the ring one. The correction to the eigenfrequency of azimuthal surface modes caused by this feature of the plasma column section is proved to increase with decreasing the external magnetic field and increasing the value of the dielectric constant of the dielectric, that separates the plasma from the metal wall of the waveguide. The spectral composition of the wave packet, in the form of which these modes propagate, is studied. The amplitudes of the satellite harmonics of these modes are found to increase with increasing the plasma density and decreasing the external magnetic field.  相似文献   

13.
In this work, we report a biopsy‐needle compatible rigid probe, capable of performing three‐dimensional (3D) two‐photon optical biopsy. The probe has a small outer diameter of 1.75 mm and fits inside a gauge‐14 biopsy needle to reach internal organs. A carefully designed focus scanning mechanism has been implemented in the rigid probe, which, along with a rapid two‐dimensional MEMS scanner, enables 3D imaging. Fast image acquisition up to 10 frames per second is possible, dramatically reducing motion artifacts during in vivo imaging. Equipped with a high‐numerical aperture micro‐objective, the miniature rigid probe offers a high two‐photon resolution (0.833 × 6.11 μm, lateral × axial), a lateral field of view of 120 μm, and an axial focus tuning range of 200 μm. In addition to imaging of mouse internal organs and subcutaneous tumor in vivo, first‐of‐its‐kind depth‐resolved two‐photon optical biopsy of an internal organ has been successfully demonstrated on mouse kidney in vivo and in situ.   相似文献   

14.
PurposeAim of this study is to experimental evaluate the impact of a 0.35 T transverse magnetic field on dose distribution in presence of tissue-air and tissue-lung interfaces.MethodsThe investigation was carried out using MRIdian (ViewRay, Cleveland, Ohio) and it consisted of comparing experimental measurements performed by Gafchromic EBT3 film dosimetry, to Montecarlo simulations, carried out in the presence and, as well as, the absence of the magnetic field.A preliminary dose calibration was planned on MRIdian, arranging 3 × 3 cm2 film pieces in a water slab phantom and exposing them at different beam-on times, in a dose range equal to 0.1–12.1 Gy.All experimental measurements were then carried out using the calibrated films and delivering one single beam orthogonally to three different phantoms: without inhomogeneity, with an air gap and with a lung inhomogeneity.The dose distributions measured by EBT3 films in presence of magnetic field were compared to those calculated in the presence and, as well as, the absence of the magnetic field, in terms of gamma analysis. A quantification of electron return effect (ERE) was also performed.ResultsAll the tested plans considering the magnetic field show a gamma-passing rate higher than 98% for 3%/3 mm gamma analysis.In presence of tissue-air interface, the electron return effect causes an over-dosage of +31.9% at the first interface and an under-dosage of −33% at the second interface. The dosimetric variations in presence of tissue-lung interface results to be smaller (+0.8% first interface, −1.3% second interface).ConclusionThe impact of 0.35 T magnetic field is not negligible and it can be effectively modelled by the Montecarlo dose calculation platform available in the MRIdian TPS.  相似文献   

15.
Magnetic resonance imaging (MRI) is a widely used method for non-invasive study of the structure and function of the human brain. Increasing magnetic field strengths enable higher resolution imaging; however, long scan times and high motion sensitivity mean that image quality is often limited by the involuntary motion of the subject. Prospective motion correction is a technique that addresses this problem by tracking head motion and continuously updating the imaging pulse sequence, locking the imaging volume position and orientation relative to the moving brain. The accuracy and precision of current MR-compatible tracking systems and navigator methods allows the quantification and correction of large-scale motion, but not the correction of very small involuntary movements in six degrees of freedom. In this work, we present an MR-compatible tracking system comprising a single camera and a single 15 mm marker that provides tracking precision in the order of 10 m and 0.01 degrees. We show preliminary results, which indicate that when used for prospective motion correction, the system enables improvement in image quality at both 3 T and 7 T, even in experienced and cooperative subjects trained to remain motionless during imaging. We also report direct observation and quantification of the mechanical ballistocardiogram (BCG) during simultaneous MR imaging. This is particularly apparent in the head-feet direction, with a peak-to-peak displacement of 140 m.  相似文献   

16.
MR-integrated radiotherapy requires suitable dosimetry detectors to be used in magnetic fields. This study investigates the feasibility of using dedicated MR-compatible ionization chambers at MR-integrated radiotherapy devices. MR-compatible ionization chambers (Exradin A19MR, A1SLMR, A26MR, A28MR) were precisely modeled and their relative response in a 6MV treatment beam in the presence of a magnetic field was simulated using EGSnrc. Monte Carlo simulations were carried out with the magnetic field in three orientations: the magnetic field aligned perpendicular to the chamber and beam axis (transverse orientation), the magnetic field parallel to the chamber as well as parallel to the beam axis. Monte Carlo simulation results were validated with measurements using an electromagnet with magnetic field strength upto 1.1 T with the chambers in transverse orientation. The measurements and simulation results were in good agreement, except for the A26MR ionization chamber in transverse orientation. The maximum increase in response of the ionization chambers observed was 8.6% for the transverse orientation. No appreciable change in chamber response due to the magnetic field was observed for the magnetic field parallel to the ionization chamber and parallel to the photon beam.Polarity and recombination correction factor were experimentally investigated in the transverse orientation. The polarity effect and recombination effect were not altered by a magnetic field.This study further investigates the response of the ionization chambers as a function of the chambers’ rotation around their longitudinal axis. A variation in response was observed when the chamber was not rotationally symmetric, which was independent of the magnetic field.  相似文献   

17.
We have developed and tested a GSO position sensitive gamma detector which can be used with positron and single-photon radionuclides for imaging breast cancer or sentinel lymph node detection. Because GSO has a relatively good energy resolution for annihilation gammas as well as low energy gamma photons, and does not contain any natural radioisotopes it can be used for positron imaging and lower energy single-photon imaging. The imaging detector consists of a GSO block, 2-inch square multichannel position sensitive photo-multiplier tube (PSPMT), and associated electronics. For the positron imaging, coincidence between the imaging detector and a single gamma probe is measured. For the single-photon imaging, a tungsten collimator is mounted in front of the imaging detector. With this configuration, it was possible to image both positron radionuclides and low energyu single-photon radionuclides.  相似文献   

18.
This work was undertaken to compare the behavior of Friend erythroleukemia cells in a solenoid, where the magnetic field was 70 μT at 50 Hz (plus 45 μT DC of Earth) with that of the same cells in a magnetically shielded room, where the magnetic field was attenuated to 20 nT DC and 2.5 pT AC. The control laboratory magnetic field corresponded to 45 μT DC and a stray 50 Hz field below 0.2 μT. The culture growth cycle of cells maintained inside the solenoid was slightly accelerated compared with that of cells maintained outside the solenoid (P < .05). This stimulation probably depended on sensitivity of cell cycle to a magnetic field, because, inside the solenoid, the percentage of G1 cells slightly increased during the culture growth cycle, whereas that of S cells slightly decreased. Acceleration of growth was detected soon after exposure of the cultures to the solenoid field, and growth did not change further if the action of this field continued for a long time, accounting for adaptation. The solenoid field also caused a small increase of cell survival without influencing cell volume. By contrast, the culture growth cycle of cells maintained inside the magnetically shielded room was slightly decelerated compared with that of cells maintained outside the room (P < .05). The essential absence of any field inside the magnetically shielded room also caused a small increase of cell volume, whereas, during the culture growth cycle, the percentage of G1 cells decreased, and that of S cells increased. The majority of these events did not change in cells induced to differentiate hemoglobin through dimethylsulfoxide. Bioelectromagnetics 18:58–66, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

19.
In a cycle of investigations concerning the pathogenesis of functional changes caused by the influence of magnetic field of induction occurring in laboratory and industrial conditions glutamic pyruvic transaminase activity in external blood and morphological picture of cardiac muscle, skeletal muscles, kidneys, cerebellum and lung tissue in guinea pigs were examined. Static homogeneous magnetic field as low as 0.005 T produced a statistically significant decrease in GPT activity. The animals were exposed to the magnetic field action for seven weeks 1 hour a day, 7 days a week. The range of observed changes of enzyme activity were determined by the duration of magnetic field. No morphological changes were observed.  相似文献   

20.
The echoplanar technique in magnetic resonance (MR) imaging allows the acquisition of a series of images from a selected slice with a temporal resolution of 10/s. Simultaneous recording of physiological information on pulse and respiration allows correlation of the MR signal intensity with physiological signals, which can be obtained for each pixel examined. Such correlations can be found within the cerebrospinal fluid (CSF) spaces and within vessels if a flow-sensitive MR measurement technique is used. The use of an MR scanner with a field strength of 3 T improves the signal/noise ratio, but there is a stronger signal decay due to local magnetic inhomogeneities. This study shows that 3-T systems can be used for correlation of MR and physiological signals and that clear differentiation between signals from CSF and from vessels can be obtained due to their strongly different signal decays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号