首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microbeam Radiation Therapy (MRT) exploits tumour selectivity and normal tissue sparing with spatially fractionated kilovoltage X-ray microbeams through the dose volume effect. Experimental measurements with Ta2O5 nanoparticles (NPs) in 9L gliosarcoma treated with MRT at the Australian Synchrotron, increased the treatment efficiency. Ta2O5 NPs were observed to form shells around cell nuclei which may be the reason for their efficiency in MRT. In this article, our experimental observation of NP shell formation is the basis of a Geant4 radiation transport study to characterise dose enhancement by Ta2O5 NPs in MRT. Our study showed that NP shells enhance the physical dose depending microbeam energy and their location relative to a single microbeam. For monochromatic microbeam energies below ∼70 keV, NP shells show highly localised dose enhancement due to the short range of associated secondary electrons. Low microbeam energies indicate better targeted treatment by allowing higher microbeam doses to be administered to tumours and better exploit the spatial fractionation related selectivity observed with MRT. For microbeam energies above ∼100 keV, NP shells extend the physical dose enhancement due to longer-range secondary electrons. Again, with NPs selectively internalised, the local effectiveness of MRT is expected to increase in the tumour. Dose enhancement produced by the shell aggregate varied more significantly in the cell population, depending on its location, when compared to a homogeneous NP distribution. These combined simulation and experimental data provide first evidence for optimising MRT through the incorporation of newly observed Ta2O5 NP distributions within 9L cancer cells.  相似文献   

2.
The BioMedical Imaging and Therapy (BMIT) facility [1,2] located at the Canadian Light Source, provides synchrotron-specific imaging and radiation therapy capabilities. There are two separate beamlines used for experiments: the bending magnet (05B1-1) and the insertion device (05ID-2) beamline.The bending magnet beamline provides access to monochromatic beam spanning a spectral range of 15–40 keV, and the beam is 240 mm wide in the POE-2 experimental hutch. Users can also perform experiments with polychromatic (pink) beam.The insertion device beamline was officially opened for general user program in 2015. The source for the ID beamline is a multi-pole, superconducting 4.3 T wiggler. The high field gives a critical energy over 20 keV. The optics hutches prepare a beam that is 220 mm wide in the last experimental hutch SOE-1. The monochromatic spectral range spans 25–150+ keV. Several different X-ray detectors are available for both beamlines, with resolutions ranging from 2 μm to 200 μm.BMIT provides a number of imaging techniques including standard absorption X-ray imaging, K-edge subtraction imaging (KES), in-line phase contrast imaging (also known as propagation based imaging, PBI) and Diffraction Enhanced Imaging/Analyzer Based Imaging (DEI/ABI), all in either projection or CT mode. PBI and DEI/ABI are particularly important tools for BMIT users since these techniques enable visualization of soft tissue and allow for low dose imaging.  相似文献   

3.
PurposeTo evaluate the influence of energy spectra, mesh sizes, high Z element on dose and PVDR in Microbeam Radiation Therapy (MRT) based on 1-D analogy-mouse-head-model (1-D MHM) and 3-D voxel-mouse-head-phantom (3-D VMHP) by Monte Carlo simulation.MethodsA Microbeam-Array-Source-Model was implemented into EGSnrc/DOSXYZnrc. The microbeam size is assumed to be 25 μm, 50 μm or 75 μm in thickness and fixed 1 mm in height with 200 μm c-t-c. The influence of the energy spectra of ID17@ESRF and BMIT@CLS were investigated. The mesh size was optimized. PVDR in 1-D MHM and 3-D VMHP was compared with the homogeneous water phantom. The arc influence of 3-D VMHP filled with water (3-D VMHWP) was compared with the rectangle phantom.ResultsPVDR of the lower BMIT@CLS spectrum is 2.4 times that of ID17@ESRF for lower valley dose. The optimized mesh is 5 µm for 25 µm, and 10 µm for 50 µm and 75 µm microbeams with 200 µm c-t-c. A 500 μm skull layer could make PVDR difference up to 62.5% for 1-D MHM. However this influence is limited (<5%) for the farther homogeneous media (e.g. 600 µm). The peak dose uniformity of 3-D VMHP at the same depth could be up to 8% for 1.85 mm × 1 mm irradiation field, whereas that of 3-D VMHWP is <1%. The high Z element makes the dose uniformity enhance in target. The surface arc could affect the superficial PVDR (from 44% to 21% in 0.2 mm depth), whereas this influence is limited for the more depth (<1%).ConclusionAn accurate MRT dose calculation algorithm should include the influence of 3-D heterogeneous media.  相似文献   

4.
We aimed to develop a new method for evaluating the drag in front-crawl swimming at various velocities and at full stroke. In this study, we introduce the basic principle and apparatus for the new method, which estimates the drag in swimming using measured values of residual thrust (MRT). Furthermore, we applied the MRT to evaluate the active drag (Da) and compared it with the passive drag (Dp) measured for the same swimmers. Da was estimated in five-stages for velocities ranging from 1.0 to 1.4 m s−1; Dp was measured at flow velocities ranging from 0.9 to 1.5 m s−1 at intervals of 0.1 m s−1. The variability in the values of Da at MRT was also investigated for two swimmers. According to the results, Da (Da = 32.3 v3.3, N = 30, R2 = 0.90) was larger than Dp (Dp = 23.5 v2.0, N = 42, R2 = 0.89) and the variability in Da for the two swimmers was 6.5% and 3.0%. MRT can be used to evaluate Da at various velocities and is special in that it can be applied to various swimming styles. Therefore, the evaluation of drag in swimming using MRT is expected to play a role in establishing the fundamental data for swimming.  相似文献   

5.
Upon induction of DNA damage by ionizing radiation (IR), members of the phosphatidylinositol 3-kinase-like kinase family of proteins namely ataxia-telangiectasia mutated (ATM), DNA-PKcs, and ATM- and Rad3-related (ATR) maintain genomic integrity by mounting DNA damage response (DDR). Recent reports suggest that activation of ATM and ATR are oppositely regulated by the length of single stranded overhangs generated during end processing by nucleases at the break sites. These stretches of single stranded overhangs hold the clue for the transition from ATM to ATR signaling at broken DNA ends. We investigated whether differential processing of breaks induced by low and high LET radiation augments the phenomenon of switching from ATM to ATR kinase and hence a concomitant NHEJ to HR transition at the sites of DNA damage. 82-6 human fibroblasts were irradiated with 1 or 2 Gy of γ-rays and particle radiation of increasing LET in order to increase the complexity and variability of DNA double strand breaks (DSB) structures. The activation kinetics of ATM and ATR kinases along with their downstream substrates were determined utilizing Western blotting and immunofluorescence techniques. Our data provide evidence of a potential switch from ATM to ATR kinase signaling in cells treated with γ-rays at approximately 2 h post irradiation, with induction and completion of resection denoted by Rad51 foci resolution kinetics and observed with a significant decline of phosphorylated ATR kinase 8 h after IR. On the other hand, irradiation with high LET 600 MeV/u 56Fe (180 keV/μm) and 170 MeV/u 28Si (99 keV/μm) particles show a similar Rad51 foci decay kinetics, however, exhibiting prolonged resection, evident by the persistent phosphorylated ATM and ATR kinase until 24 h post irradiation. This residual effect, however, was significantly reduced for 250 MeV/u 16O particles of moderate LET (25 keV/μm) and absent for γ-rays. Hence, our results support the hypothesis that the transition from ATM to ATR signaling at DNA break sites is extended for longer periods of time, indicated by sustained resection due to the complex type of damage induced, a hallmark of high LET radiation, which may contribute to its increased biological effectiveness.  相似文献   

6.
Irradiation, delivered by a synchrotron facility, using a set of highly collimated, narrow and parallel photon beams spaced by 1 mm or less, has been termed Microbeam Radiation Therapy (MRT). The tolerance of healthy tissue after MRT was found to be better than after standard broad X-ray beams, together with a more pronounced response of malignant tissue. The microbeam spacing and transverse peak-to-valley dose ratio (PVDR) are considered to be relevant biological MRT parameters. We investigated the MRT concept for proton microbeams, where we expected different depth-dose profiles and PVDR dependences, resulting in skin sparing and homogeneous dose distributions at larger beam depths, due to differences between interactions of proton and photon beams in tissue. Using the FLUKA Monte Carlo code we simulated PVDR distributions for differently spaced 0.1 mm (sigma) pencil-beams of entrance energies 60, 80, 100 and 120 MeV irradiating a cylindrical water phantom with and without a bone layer, representing human head. We calculated PVDR distributions and evaluated uniformity of target irradiation at distal beam ranges of 60–120 MeV microbeams. We also calculated PVDR distributions for a 60 MeV spread-out Bragg peak microbeam configuration. Application of optimised proton MRT in terms of spot size, pencil-beam distribution, entrance beam energy, multiport irradiation, combined with relevant radiobiological investigations, could pave the way for hypofractionation scenarios where tissue sparing at the entrance, better malignant tissue response and better dose conformity of target volume irradiation could be achieved, compared with present proton beam radiotherapy configurations.  相似文献   

7.
Introducing a sulfamide moiety to our coumarin derivatives afforded enhanced Raf/MEK inhibitory activity concomitantly with an acceptable PK profile. Novel sulfamide 17 showed potent HCT116 cell growth inhibition (IC50 = 8 nM) and good PK profile (bioavailability of 51% in mouse), resulting in high in vivo antitumor efficacy in the HCT116 xenograft (ED50 = 4.8 mg/kg). We confirmed the sulfamide moiety showed no negative impact on tests run on the compound to evaluate DMPK (PK profiles in three animal species, CYP inhibition and CYP induction) and the safety profile (hERG and AMES tests). Sulfamide 17 had favorable properties that warranted further preclinical assessment  相似文献   

8.
PurposeWe performed the first investigations, via measurements and Monte Carlo simulations on phantoms, of the feasibility of a new technique for synchrotron radiation rotational radiotherapy for breast cancer (SR3T).MethodsA Monte Carlo (MC) code based on Geant4 toolkit was developed in order to simulate the irradiation with the SR3T technique and to evaluate the skin sparing effect in terms of centre-to-periphery dose ratio at different energies in the range 60–175 keV. Preliminary measurements were performed at the Australian Synchrotron facility. Radial dose profiles in a 14-cm diameter polyethylene phantom were measured with a 100-mm pencil ionization chamber for different beam sizes and compared with the results of MC simulations. Finally, the dose painting feasibility was demonstrated with measurements with EBT3 radiochromic films in a phantom and collimating the SR beam at 1.5 cm in the horizontal direction.ResultsMC simulations showed that the SR3T technique assures a tumour-to-skin absorbed dose ratio from about 7:1 (at 60 keV photon energy) to about 10:1 (at 175 keV), sufficient for skin sparing during radiotherapy. The comparison between the results of MC simulations and measurements showed an agreement within 5%. Two off-centre foci were irradiated shifting the rotation centre in the horizontal direction.ConclusionsThe SR3T technique permits to obtain different dose distributions in the target with multiple rotations and can be guided via synchrotron radiation breast computed tomography imaging, in propagation based phase-contrast conditions. Use of contrast agents like iodinated solutions or gold nanoparticles for dose enhancement (DE-SR3T) is foreseen and will be investigated in future work.  相似文献   

9.
PurposeTo find the optimum parameter of a new beam control function installed in a synchrotron-based proton therapy system.MethodsA function enabling multiple gated irradiation in the flat top phase has been installed in a real-time-image gated proton beam therapy (RGPT) system. This function is realized by a waiting timer that monitors the elapsed time from the last gate-off signal in the flat top phase. The gated irradiation efficiency depends on the timer value, Tw. To find the optimum Tw value, gated irradiation efficiency was evaluated for each configurable Tw value. 271 gate signal data sets from 58 patients were used for the simulation.ResultsThe highest mean efficiency 0.52 was obtained in TW = 0.2 s. The irradiation efficiency was approximately 21% higher than at TW = 0 s, which corresponds to ordinary synchrotron operation. The irradiation efficiency was improved in 154 (57%) of the 271 cases. The irradiation efficiency was reduced in 117 cases because the TW value was insufficient or the function introduced an unutilized wait time for the next gate-on signal in the flat top phase. In the actual treatment of a patient with a hepatic tumor at Tw = 0.2 s, 4.48 GyE irradiation was completed within 250 s. In contrast, the treatment time of ordinary synchrotron operation was estimated to be 420 s.ConclusionsThe results suggest that the multiple gated-irradiation function has potential to improve the gated irradiation efficiency and to reduce the treatment time.  相似文献   

10.
Irradiating a tumor bed with boost dose after whole breast irradiation helps reducing the probability of local recurrence. However, the success of electron beam treatment with a small area aiming to cover a superficial lesion is a dual challenge as it requires an adequate dosimetry beside a double check for dose coverage with an estimation of various combined uncertainty of tumor location and losing lateral electron equilibrium within small field dimensions.Aim of workthis work aims to measure the electron beam fluence within different field dimensions and the deviation from measurement performed in standard square electron applicator beam flatness and symmetry, then to calculate the average range of the correction factor required to overcome the loss of lateral electron equilibrium.Material and methodthe electron beam used in this work generated from the linear accelerator model ELEKTA Precise and dosimetry system used were a pair of PTW Pin Point ion chambers for electron beam dosimetry at standard conditions and assessment of beam quality at a reference depth of measurement, with an automatic water phantom, then a Roos ion chamber was used for absolute dose measurement, and PTW 2Darray to investigate the beam fluence of four applicators 6, 10, 14 and 20 cm2 and 4 rectangular cutouts 6 × 14, 8 × 14, 6 × 17 and 8 × 17 cm2, the second part was clinical application which was performed in a precise treatment planning system and examined boost dose after whole breast irradiation.Resultsrevealed that lower energy (6MeV and 8MeV) showed the loss of lateral electron equilibrium and deviation from measurements of a standard applicator more than the high energy (15 MeV) which indicated that the treatment of superficial dose with 6MeV required higher monitor unit to allow for the loss of lateral electron equilibrium and higher margin as well.  相似文献   

11.
Arteriovenous anastomoses (AVA) in acral skin (palms and soles) have a huge capacity to shunt blood directly from the arteries to the superficial venous plexus of the extremities. We hypothesized that acral skin, which supplies blood to the superficial venous plexus, has a stronger influence on blood flow adjustments during cooling in thermoneutral subjects than does non-acral skin. Thirteen healthy subjects were exposed to stepwise cooling from 32 °C to 25 °C and 17 °C in a climate chamber. Laser Doppler flux and skin temperature were measured simultaneously from the left and right third finger pulp and bilateral upper arm skin. Coherence and correlation analyses were performed of short-term fluctuations at each temperature interval. The flux from finger pulps showed the synchronous spontaneous fluctuations characteristic of skin areas containing AVAs. Fluctuation frequency, amplitude and synchronicity were all higher at 25 °C than at 32 °C and 17 °C (p<0.02). Bilateral flux from the upper arm skin showed an irregular, asynchronous vasomotor pattern with small amplitudes which were independent of ambient temperature. At 32 °C, ipsilateral median flux values from the right arm (95% confidence intervals) were 492 arbitrary units (au) (417, 537) in finger pulp and 43 au (35, 60) in upper arm skin. Flux values gradually decreased in finger pulp to 246 au (109, 363) at 25 °C, before an abrupt fall occurred at a median room temperature of 24 °C, resulting in a flux value of 79 au (31, 116) at 17 °C. In the upper arm skin a gradual fall throughout the cooling period to 21 au (13, 27) at 17 °C was observed. The fact that the response of blood flow to ambient cooling is stronger in acral skin than in non-acral skin suggests that AVAs have a greater capacity to adjust blood flow in thermoneutral zone than arterioles in non-acral skin.  相似文献   

12.
13.
The disrupted autoimmune response in Hashimoto’s thyroiditis (HT) has long been considered to be dominantly T helper type 1 (Th1) mediated. Recent advances in the field of immunology have introduced a new class of effector T cells, named ‘Th17’, which plays important roles in autoimmune disorders once thought to be merely Th1 mediated. We aimed to examine the levels of major Th17 cytokines in patients with HT in this study. We studied serum interleukin 17 (IL-17) and interleukin 23 (IL-23) levels in 46 newly diagnosed, untreated patients with HT (40 women and 6 men, aged 40.0 ± 11.8 years) divided into euthyroid (n = 22) and hypothyroid (n = 24) groups and compared them with age and sex matched 26 healthy euthyroid controls without HT (21 women and 5 men; aged 36.0 ± 12.9 years). Serum IL-17 and IL-23 levels were significantly different among euthyroid and hypothyroid HT patients and controls, with highest levels obtained in the euthyroid HT group (p = 0.041 for IL-17 and p < 0.001 for IL-23). TSH was negatively and FT4 was positively correlated with IL-17 (p = 0.016 for TSH and p = 0.004 for FT4) and IL-23 (p < 0.001 for TSH and p = 0.003 for FT4) levels. There were no correlations between thyroid volumes calculated on thyroid ultrasonography and IL-17 (p = 0.630) or IL-23 (p = 0.321) levels. In conclusion, the levels of IL-17, one of the major effector cytokines of the Th17 system, and IL-23, which had been implicated in the generation, survival and expansion of Th17 cells, are altered in HT. How thyroid hormone status and the course of disease affect Th17 system in chronic autoimmune thyroiditis needs to be determined with further studies.  相似文献   

14.
PurposeTo measure the environmental doses from stray neutrons in the vicinity of a solid slab phantom as a function of beam energy, field size and modulation width, using the proton pencil beam scanning (PBS) technique.MethodMeasurements were carried out using two extended range WENDI-II rem-counters and three tissue equivalent proportional counters. Detectors were suitably placed at different distances around the RW3 slab phantom. Beam irradiation parameters were varied to cover the clinical ranges of proton beam energies (100–220 MeV), field sizes ((2 × 2)–(20 × 20) cm2) and modulation widths (0–15 cm).ResultsFor pristine proton peak irradiations, large variations of neutron H1(10)/D were observed with changes in beam energy and field size, while these were less dependent on modulation widths. H1(10)/D for pristine proton pencil beams varied between 0.04 μSv Gy−1 at beam energy 100 MeV and a (2 × 2) cm2 field at 2.25 m distance and 90° angle with respect to the beam axis, and 72.3 μSv Gy−1 at beam energy 200 MeV and a (20 × 20) cm2 field at 1 m distance along the beam axis.ConclusionsThe obtained results will be useful in benchmarking Monte Carlo calculations of proton radiotherapy in PBS mode and in estimating the exposure to stray radiation of the patient. Such estimates may be facilitated by the obtained best-fitted simple analytical formulae relating the stray neutron doses at points of interest with beam irradiation parameters.  相似文献   

15.
The objective of this work was to evaluate the performance of a two-stage hydrogenogenic–methanogenic (H–M) semi-continuous process in terms of mass retention time (MRT) for hydrogenogenic stage (H-stage), feed source for methanogenic stage (M-stage) and thermal regime (35 and 55 °C) for both stages. The substrate was a model organic fraction of municipal solid wastes (OFMSW) at 35% total solids.In H-stage, mesophilic temperature had a positive significant effect on higher hydrogen productivities and lower amounts of hydrogen sinks compared to thermophilic operation. Calculations based on mass balances and biochemical stoichiometry confirmed that acid fermentation deviation was linked to low biohydrogen yields. The M-stage performance was influenced by both the temperature and feed source. Bioreactors in thermophilic regime performed better than mesophilic ones. Maximum methane productivity was 341 NmL CH4/(kgwmr d) that corresponded to the thermophilic bioreactor fed with fermented solids from H stage at 14 d MRT. The two-stage process showed higher gross energetic potential when compared to an only methanogenic process operated at equivalent MRT (control); this was due to a higher methane productivity in the M-stage of the series process. The main contribution of H-stage seemed to be associated to hydrolysis of the complex substrate thus generating metabolites for the M-stage rather than the hydrogen production itself.  相似文献   

16.
AimsThe aim of the present study was to investigate the effects of different periods of ovariectomy and 17β-estradiol replacement on apoptotic cell death and expression of members of the Bcl-2 family in the rat hippocampus.Main methodsHippocampi were obtained from rats in proestrus, ovariectomized (15 days, 21 days and 36 days), ovariectomized for 15 days and then treated with 17β-estradiol for 7 or 21 days, and rats ovariectomized and immediately treated with 17β-estradiol for 21 days.The expression of Bcl-2 and Bax and the number of apoptotic cells were determined.Key findingsOvariectomy decreased Bcl-2 expression and increased Bax expression and the number of apoptotic cells. Replacement with 17β-estradiol (21 days) throughout the post-ovariectomy period reduced the number of apoptotic cells to the control levels, and prevented the effects of ovariectomy on Bax expression, but only partially restored the Bcl-2 expression. After 15 days of ovariectomy, the replacement with 17β-estradiol for 21 days, but not for 7 days, restored the Bcl-2 and Bax expression and the percentage of apoptotic cells to the levels found in the proestrus control.SignificanceThe present results show that a physiological concentration of 17β-estradiol may help maintain long-term neuronal viability by regulating the expression of members of the Bcl-2 family. Even after a period of hormonal deprivation, treatment with 17β-estradiol is able to restore the expression of Bax and Bcl-2 to control levels, but the duration of the treatment is a key factor to obtain the desired effect. These data provide new understanding into the mechanisms contributing to the neuroprotective action of estrogen.  相似文献   

17.
PurposeDynamic treatment planning algorithms use a dosimetric leaf separation (DLS) parameter to model the multi-leaf collimator (MLC) characteristics. Here, we quantify the dosimetric impact of an incorrect DLS parameter and investigate whether common pretreatment quality assurance (QA) methods can detect this effect.Methods16 treatment plans with intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) technique for multiple treatment sites were calculated with a correct and incorrect setting of the DLS, corresponding to a MLC gap difference of 0.5 mm. Pretreatment verification QA was performed with a bi-planar diode array phantom and the electronic portal imaging device (EPID). Measurements were compared to the correct and incorrect planned doses using gamma evaluation with both global (G) and local (L) normalization. Correlation, specificity and sensitivity between the dose volume histogram (DVH) points for the planning target volume (PTV) and the gamma passing rates were calculated.ResultsThe change in PTV and organs at risk DVH parameters were 0.4–4.1%. Good correlation (>0.83) between the PTVmean dose deviation and measured gamma passing rates was observed. Optimal gamma settings with 3%L/3 mm (per beam and composite plan) and 3%G/2 mm (composite plan) for the diode array phantom and 2%G/2 mm (composite plan) for the EPID system were found. Global normalization and per beam ROC analysis of the diode array phantom showed an area under the curve <0.6.ConclusionsA DLS error can worsen pretreatment QA using gamma analysis with reasonable credibility for the composite plan. A low detectability was demonstrated for a 3%G/3 mm per beam gamma setting.  相似文献   

18.
Stereotactic Synchrotron Radiotherapy (SSRT) and Microbeam Radiation Therapy (MRT) are both novel approaches to treat brain tumor and potentially other tumors using synchrotron radiation. Although the techniques differ by their principles, SSRT and MRT share certain common aspects with the possibility of combining their advantages in the future. For MRT, the technique uses highly collimated, quasi-parallel arrays of X-ray microbeams between 50 and 600 keV. Important features of highly brilliant Synchrotron sources are a very small beam divergence and an extremely high dose rate. The minimal beam divergence allows the insertion of so called Multi Slit Collimators (MSC) to produce spatially fractionated beams of typically ∼25–75 micron-wide microplanar beams separated by wider (100–400 microns center-to-center(ctc)) spaces with a very sharp penumbra. Peak entrance doses of several hundreds of Gy are extremely well tolerated by normal tissues and at the same time provide a higher therapeutic index for various tumor models in rodents. The hypothesis of a selective radio-vulnerability of the tumor vasculature versus normal blood vessels by MRT was recently more solidified.SSRT (Synchrotron Stereotactic Radiotherapy) is based on a local drug uptake of high-Z elements in tumors followed by stereotactic irradiation with 80 keV photons to enhance the dose deposition only within the tumor. With SSRT already in its clinical trial stage at the ESRF, most medical physics problems are already solved and the implemented solutions are briefly described, while the medical physics aspects in MRT will be discussed in more detail in this paper.  相似文献   

19.
AimTo discuss current dosage for stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) patients and suggest alternative treatment strategies according to liver segmentation as defined by the Couinaud classification.BackgroundSBRT is a safe and effective alternative treatment for HCC patients who are unable to undergo liver ablation/resection. However, the SBRT fractionation schemes and treatment planning strategies are not well established.Materials and methodsIn this article, the latest developments and key findings from research studies exploring the efficacy of SBRT fractionation schemes for treatment of HCC are reviewed. Patients’ characteristics, fractionation schemes, treatment outcomes and toxicities were compiled. Special attention was focused on SBRT fractionation approaches that take into consideration liver segmentation according to the Couinaud classification and functional hepatic reserve based on Child–Pugh (CP) liver cirrhosis classification.ResultsThe most common SBRT fractionation schemes for HCC were 3 × 10–20 Gy, 4–6 × 8–10 Gy, and 10 × 5–5.5 Gy. Based on previous SBRT studies, and in consideration of tumor size and CP classification, we proposed 3 × 15–25 Gy for patients with tumor size <3 cm and adequate liver reserve (CP-A score 5), 5 × 10–12 Gy for patients with tumor sizes between 3 and 5 cm or inadequate liver reserve (CP-A score 6), and 10 × 5–5.5 Gy for patients with tumor size >5 cm or CP-B score.ConclusionsTreatment schemes in SBRT for HCC vary according to liver segmentation and functional hepatic reserve. Further prospective studies may be necessary to identify the optimal dose of SBRT for HCC.  相似文献   

20.
We measured the concentrations of selected persistent organic pollutants (POPs) such as parent and halogenated polycyclic aromatic hydrocarbons (PAHs and HPAHs) and polybrominated diphenyl ethers (PBDEs) in indoor dust (ID) and indoor cockroach samples collected from Shenzhen, South China. Biota-dust accumulation factors (BDAFs) were computed and utilized to quantify targeted pollutant bioaccumulation in ID and cockroaches. Generally, halogenated compounds have higher BDAFs when compared to non-halogenated compounds. There are significant differences (p < 0.05) between the BDAFs of non-halogenated POPs (PAHs) and halogenated POPs (HPAHs and PBDEs). Correlation analysis of target pollutants’ levels in ID and cockroaches were also conducted. The correlation coefficients for PAHs are less than 0.2 (p > 0.5) suggesting no significant relationship exists for PAHs between ID and cockroaches. In contrast, significant correlations exist for halogenated POPs (HPAH and PBDE) between ID and cockroaches (correlation coefficients >0.94, p < 0.0001). Based on this, the potential of cockroaches to be used as reliable bioindicators of POPs contamination of indoor environments was preliminarily evaluated. Our results indicate that indoor cockroaches may be useful bioindicator of indoor pollution for HPAHs and PBDEs contaminations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号