Background

The most often found complications in patients with breast cancer who received radiotherapy are cardiac and pulmonary function disorders and development of second malignancies.

Aim

To compare the intensity modulated radiotherapy with the 3D tangential beams technique in respect of dose distribution in target volume and critical organs they generate in patients with early-stage breast cancer who received breast-conserving therapy.

Materials and methods

A dosimetric analysis was performed to assess the three radiotherapy techniques used in each of 10 consecutive patients with early-stage breast cancer treated with breast-conserving therapy. Radiotherapy was planned with the use of all the three techniques: 3D tangential beams with electron boost, IMRT with electron boost, and intensity modulated radiotherapy with simultaneous integrated boost.

Results

The use of the IMRT techniques enables more homogenous dose distribution in target volume. The range of mean and median dose to the heart and lung was lower with the IMRT techniques in comparison to the 3D tangential beams technique. The range of mean dose to the heart amounted to 0.3–3.5 Gy for the IMRT techniques and 0.4–4.3 for the tangential beams technique. The median dose to the lung on the irradiated side amounted to 4.9–5 Gy for the IMRT techniques and 5.6 Gy for the 3D tangential beams technique.

Conclusion

The application of the IMRT techniques in radiotherapy patients with early-stage breast cancer allows to obtain more homogenous dose distribution in target volume, while permitting to reduce the dose to critical organs.  相似文献   

3.
AimThe purpose of this study was to investigate the dosimetric characteristics of three stereotactic ablative body radiotherapy (SABR) techniques using the anisotropic analytical algorithm (AAA) and Acuros XB algorithm. The SABR techniques include coplanar volumetric modulated arc therapy (C-VMAT), non-coplanar intensity modulated radiation therapy (NC-IMRT) and non-coplanar three-dimensional conformal radiotherapy (NC-3D CRT).BackgroundSABR is a special type of radiotherapy where a high dose of radiation is delivered over a short time. The treatment outcome and accuracy of the dose delivered to cancer patients highly depend on the dose calculation algorithm and treatment technique.Materials and methodsTwelve lung cancer patients underwent 4D CT scanning, and three different treatment plans were generated: C-VMAT, NC-IMRT, NC-3D CRT. Dose calculation was performed using the AAA and Acuros XB algorithm. The dosimetric indices, such as conformity index (CI), homogeneity index, dose fall-off index, doses received by organs at risk and planning target volume, were used to compare the plans. The accuracy of AAA and Acuros XB (AXB) algorithms for the lung was validated against measured dose on a CIRS thorax phantom.ResultsThe CIs for C-VMAT, NC-IMRT and NC-3D CRT were 1.21, 1.28 and 1.38 for the AAA, respectively, and 1.17, 1.26 and 1.36 for the Acuros XB algorithm, respectively. The overall dose computed by AcurosXB algorithm was close to the measured dose when compared to the AAA algorithm. The overall dose computed by the AcurosXB algorithm was close to the measured dose when compared to the AAA algorithm.ConclusionThis study showed that the treatment planning results obtained using the Acuros XB algorithm was better than those using the AAA algorithm in SABR lung radiotherapy.  相似文献   

4.
5.
PurposeAccelerated partial breast irradiation (APBI) is alternative treatment option for patients with early stage breast cancer. The interplay effect on volumetric modulated arc therapy APBI (VMAT-APBI) has not been clarified. This study aimed to evaluate the feasibility of VMAT-APBI for patients with small breasts and investigate the amplitude of respiratory motion during VMAT-APBI delivery that significantly affects dose distribution.MethodsThe VMAT-APBI plans were generated with 28.5 Gy in five fractions. We performed patient-specific quality assurance using Delta4 phantom under static conditions. We also measured point dose and dose distribution using the ionization chamber and radiochromic film under static and moving conditions of 2, 3 and 5 mm. We compared the measured and calculated point doses and dose distributions by dose difference and gamma passing rates.ResultsA total of 20 plans were generated; the dose distributions were consistent with those of previous reports. For all measurements under static conditions, the measured and calculated point doses and dose distributions showed good agreement. The dose differences for chamber measurement were within 3%, regardless of moving conditions. The mean gamma passing rates with 3%/2 mm criteria in the film measurement under static conditions and with 2 mm, 3 mm, and 5 mm of amplitude were 95.0 ± 2.0%, 93.3 ± 3.3%, 92.1 ± 6.2% and 84.8 ± 7.8%, respectively. The difference between 5 mm amplitude and other conditions was statistically significant.ConclusionsRespiratory management should be considered for the risk of unintended dose distribution if the respiratory amplitude is >5 mm.  相似文献   

6.
PurposeAccurate calculation of the proton beam range inside a patient is an important topic in proton therapy. In recent times, a computed tomography (CT) image reconstruction algorithm was developed for treatment planning to reduce the impact of the variation of the CT number with changes in imaging conditions. In this study, we investigated the usefulness of this new reconstruction algorithm (DirectDensity™: DD) in proton therapy based on its comparison with filtered back projection (FBP).MethodsWe evaluated the effects of variations in the X-ray tube potential and target size on the FBP- and DD-image values and investigated the usefulness of the DD algorithm based on the range variations and dosimetric quantity variations.ResultsFor X-ray tube potential variations, the range variation in the case of FBP was up to 12.5 mm (20.8%), whereas that of DD was up to 3.3 mm (5.6%). Meanwhile, for target size variations, the range variation in the case of FBP was up to 2.2 mm (2.5%), whereas that of DD was up to 0.9 mm (1.4%). Moreover, the variations observed in the case of DD were smaller than those of FBP for all dosimetric quantities.ConclusionThe dose distributions obtained using DD were more robust against variations in the CT imaging conditions (X-ray tube potential and target size) than those obtained using FBP, and the range variations were often less than the dose calculation grid (2 mm). Therefore, the DD algorithm is effective in a robust workflow and reduces uncertainty in range calculations.  相似文献   

7.
PurposeTo analyse the impact of different optimization strategies on the compatibility between planned and delivered doses during radiotherapy of cervical cancer.Material/methodsFour treatment plans differing in optimisation strategies were prepared for ten cervical cancer cases. These were: volumetric modulated arc therapy with (_OPT) and without optimization of the doses in the bone marrow and for two sets of margins applied to the clinical target volume that arose from image guidance based on the bones (IG(B)) and soft tissues (IG(ST)). The plans were subjected to dosimetric verification by using the ArcCHECK system and 3DVH software. The planned dose distributions were compared with the corresponding measured dose distributions in the light of complexity of the plans and its deliverability.ResultsThe clinically significant impact of the plans complexity on their deliverability is visible only for the gamma passing rates analysis performed in a local mode and directly in the organs. While more general analyses show statistically significant differences, the clinical relevance of them has not been confirmed. The analysis showed that IG(ST)_OPT and IG(B)_OPT significantly differ from IG(ST) and IG(B). The clinical acceptance of IG(ST)_OPT obtained for hard combinations of gamma acceptance criteria (2%/2 mm) confirm its satisfactory deliverability. In turn, for IG(B)_OPT in the case of the rectum, the combination of 2%/2 mm did not meet the criteria of acceptance.ConclusionDespite the complexity of the IG(ST)_OPT, the results of analysis confirm the acceptance of its deliverability when 2%/2 mm gamma acceptance criteria are used during the analysis.  相似文献   

8.

Background

IMRT provides highly conformal dose distributions creating non uniform spatial intensity using different segments in the beam.

Material & Methods and Results

Different retrospective studies have shown a high capability of IMRT to treat tumours close to the base of skull. Prospective studies have shown a decrease in xerostomia compared with conventional 3D conformal treatment (3DCRT). Modulation of intensity is performed by the movement of the multileaf collimator (MLC) that can deliver the radiation in different ways, such as static field segments, dynamic field segments and rotational delivery (arc therapy and tomotherapy). There are slight differences among the different techniques in terms of homogeneity, dose conformity and treatment delivery time.

Conclusions

The best method to deliver IMRT will depend on multiple factors such as deliverability, practicality, user training and plan quality.  相似文献   

9.

Aim

This study aimed to evaluate the treatment result of intensity-modulated radiation therapy (IMRT) in a large number of Japanese patients with prostate cancer.

Background

A total of 1091 patients with localized prostate cancer were recruited between March 2006 and July 2014. The patients were stratified into low- (n = 205 [18.8%]), intermediate- (n = 450 [41.2%]), high- (n = 345 [31.6%]), and very high-risk (n = 91 [8.3%]) groups according to the National Comprehensive Cancer Network classification. All patients were irradiated via IMRT at a dose of 74–78 Gy with or without androgen-deprivation therapy. The mean follow-up period was 50 months (range, 2–120 months).

Results

The biochemical failure-free rate (BFFR), the clinical failure-free rate, and the overall survival rate at the 5-year follow-up for all patients was 91.3%, 96.2%, and 99.1%, respectively. In univariate analysis, the prostate-specific antigen (PSA) levels (≤20 vs. >20 ng/ml) were significantly correlated with BFFR. A trend toward higher BFFR was noted in patients with a Gleason score (GS) of ≤7 than in patients with GS ≥8. In multivariate analysis, only PSA (≤20 vs. >20 ng/ml) was significantly correlated with BFFR. The cumulative incidence rate of gastrointestinal and genitourinary toxicity (≥grade 2) at the 5-year follow-up was 11.4% and 4.3%, respectively.

Conclusions

The findings of this study indicate that IMRT is well tolerated and is associated with both good long-term tumor control and excellent outcomes in patients with localized prostate cancer.  相似文献   

10.
11.
PurposeWhen using volumetric modulated arc therapy (VMAT) for head and neck cancer, setup errors regarding the shoulders can create loss of target coverage or increased organ-at-risk doses. This study created variations of realistic shoulder deformations to understand the associated VMAT dosimetric effects and investigated water-equivalent thickness (WET) differences using in-house software.MethodsTen patients with head and neck cancer with lower neck involvement were retrospectively and randomly enrolled. Their retrospective analysis comprised treatment planning using RayStation 5.0 (RaySearch Laboratories, Stockholm, Sweden), shoulder deformation of 5–15 mm in three-dimensional axes using the ImSimQA package (Oncology Systems Limited, Shrewsbury, Shropshire, UK), and evaluation of the clinical impact of the dose distribution after recalculating the dose distribution using computed tomography images of deformed shoulders and deforming the dose distribution. Additionally, our in-house software program was used to measure WET differences for shoulder deformation.ResultsWET differences were greater in the superoinferior (SI) direction than in the other directions (the WET difference was >20 mm for 15-mm SI deformation). D99%, D98%, and D95% for all clinical target volumes were within 3%. Local dose differences of more than ±10% were found for normal tissues at the level of the shoulder for 15-mm movement in the SI direction.ConclusionsShoulder deformation of >6 mm could cause large dose variations delivered to the targeted tissue at the level of the shoulder. Thus, to ensure delivery of appropriate treatment coverage to the targeted tissue, shoulder deformation should be taken into consideration during the planning stage.  相似文献   

12.
目的:观察调强放疗(intensity modulated radiation therapy,IMRT)对初治鼻咽癌的近期临床疗效急性毒性反应.方法:41例初治鼻咽癌患者中,按92福州分期标准,Ⅰ期1例,Ⅱ期4例,Ⅲ期13例,Ⅳ期23例;1例仅接受根治性调强放疗,其余40例均接受放化综合治疗.鼻咽大体肿瘤体积(GTVnx)处方剂量为(68~70) Gy分30~33次,颈部淋巴结(GTVnd)处方剂量为(62~66)Gy分30~33次,临床靶体积1(CTVl) (60~64) Gy分30~33次,临床靶体积2(CTV2) (50~54) Gy分30~33次.病灶靶区处方剂量为68~70 Gy.对于鼻咽癌Ⅱ、Ⅳ期患者,IMRT治疗的同时,根据淋巴结转移,以及患者的基本情况,酌情给予奈达铂+5-Fu,进行1~2周期的诱导化疗,以及单药奈达铂的同步化疗.根据RTOG /EORTC标准,对其急性反应进行评估.结果:中位随访时间1~13个月,多数患者仅表现为1~2级急性反应,观察到4级急性反应l例.1年随访期间,局部区域进展、远处转移,以及总生存率分别为95.1%、95.1%和100.0%.结论:对于早期或晚期鼻咽癌患者,IMRT均可获得理想的剂量分布,最大可能地保护正常组织,提高患者对毒副反应的耐受力,明显提高治疗的临床效果.远期疗效需进一步观察.  相似文献   

13.
14.
AimTo assess the oncological outcomes of patients with early breast cancer treated with breast-conserving surgery and adjuvant hypofractionated radiation therapy.Methods and MaterialThis retrospective analysis included all patients ≥50 year of age with T1-2 N0 M0 breast cancer treated at our Radiation Oncology Unit between 2008 and 2011. Whole-breast radiation therapy was delivered to a dose of 42.5 Gy in 16 fractions, without boost. The primary outcome was local control.Results212 patients were identified. With a median follow up of 60 months, we found 3% local recurrence and 5.3% regional and/or distant recurrences. At the moment of data analysis, 17 patients had died. Out of 5 local recurrences, 2 had previously had a distant recurrence, both of them died. The other three were still alive at the last follow up. These results are comparable to those observed in Phase III trials that use this fractionation scheme.ConclusionsThe results obtained with this retrospective analysis are comparable to those obtained in large randomized trials. This data also supports the use of hypofractionated radiation therapy in Latin America. Hypofractionated radiation therapy for early breast cancer patients should be the standard adjuvant treatment.  相似文献   

15.
AimTo compare the radiotherapy technique used in a randomised trial with VMAT and an in-house technique for prostate cancer.BackgroundTechniques are evolving with volumetric modulated arc therapy (VMAT) commonly used. The CHHiP trial used a 3 PTV forward planned IMRT technique (FP_CH). Our centre has adopted a simpler two PTV technique with locally calculated margins.Materials and methods25 patients treated with FP_CH to 60 Gy in 20 fractions were re-planned with VMAT (VMAT_CH) and a two PTV protocol (VMAT_60/52 and VMAT_60/48). Target coverage, conformity index (CI), homogeneity index (HI), monitor units (MU) and dose to the rectum, bladder, hips and penile bulb were compared.ResultsPTV coverage was high for all techniques. VMAT_CH plans had better CI than FP_CH (p   0.05). VMAT_60/52/48 plans had better CI than VMAT_CH. FP_CH had better HI and fewer MU than VMAT (p   0.05). More favourable rectum doses were found for VMAT _CH than FP_CH (V48.6, V52.8, V57, p   0.05) with less difference for bladder (p   0.05). Comparing VMAT_CH to VMAT_60/52/48 showed little differences for the bladder and rectum but VMAT_CH had larger penile bulb doses (V40.8, V48.6, mean, D2, p   0.05). Femoral head doses (V40.8) were similarly low for all techniques (p = ≥ 0.05).ConclusionVMAT produced more conformal plans with smaller rectum doses compared to FP_CH albeit worse HI and more MU. VMAT_60/52 and VMAT_60/48 plans had similar rectal and bladder doses to VMAT_CH but better CI and penile bulb doses which may reduce toxicity.  相似文献   

16.
PurposeThis treatment planning study was conducted to determine whether spot scanning proton beam therapy (SSPT) reduces the risk of grade ⩾3 hematologic toxicity (HT3+) compared with intensity modulated radiation therapy (IMRT) for postoperative whole pelvic radiation therapy (WPRT).Methods and materialsThe normal tissue complication probability (NTCP) of the risk of HT3+ was used as an in silico surrogate marker in this analysis. IMRT and SSPT plans were created for 13 gynecologic malignancy patients who had received hysterectomies. The IMRT plans were generated using the 7-fields step and shoot technique. The SSPT plans were generated using anterior-posterior field with single field optimization. Using the relative biological effectives (RBE) value of 1.0 for IMRT and 1.1 for SSPT, the prescribed dose was 45 Gy(RBE) in 1.8 Gy(RBE) per fractions for 95% of the planning target volume (PTV). The homogeneity index (HI) and the conformity index (CI) of the PTV were also compared.ResultsThe bone marrow (BM) and femoral head doses using SSPT were significantly lower than with IMRT. The NTCP modeling analysis showed that the risk of HT3+ using SSPT was significantly lower than with IMRT (NTCP = 0.04 ± 0.01 and 0.19 ± 0.03, p = 0.0002, respectively). There were no significant differences in the CI and HI of the PTV between IMRT and SSPT (CI = 0.97 ± 0.01 and 0.96 ± 0.02, p = 0.3177, and HI = 1.24 ± 0.11 and 1.27 ± 0.05, p = 0.8473, respectively).ConclusionThe SSPT achieves significant reductions in the dose to BM without compromising target coverage, compared with IMRT. The NTCP value for HT3+ in SSPT was significantly lower than in IMRT.  相似文献   

17.
PurposeTo investigate the feasibility of carotid sparing intensity modulated radiation therapy (CS-IMRT) to minimize the radiation dose to carotid arteries for comprehensive irradiation of breast cancer patients who have risk factors for atherosclerosis. The dose distribution of CS-IMRT technique and the conventional irradiation technique were also compared.Patients and methodsTen patients who were previously treated with comprehensive three-dimensional conformal radiation therapy (3DCRT) were selected. DICOM data were used to contour the carotid artery and to create the virtual CS-IMRT plans for each patient. 3DCRT and CS-IMRT plans were compared in terms of conformity index, homogeneity index, and the doses to organ at risk and carotid arteries.ResultsThe homogeneity and conformity indices were better with CS-IMRT plans compared to 3DCRT plan. The homogeneity index was 1.13 vs 1.11 (p = 0.007) for 3DCRT and CS-IMRT and the conformity index was 0.96 vs 0.97 (p = 0.006) for 3DCRT and CS-IMRT. The radiation dose to the carotid arteries were reduced by applying CS-IMRT without compromising the target volume coverage. When the carotid artery was considered as organ at risk for CS-IMRT planning, the median of V50 was decreased to 0% from 12.5% compared to 3DCRT plans (p = 0.017). The median of the maximum dose to the carotid artery was decreased under 50 Gy with CS-IMRT.ConclusionsCS-IMRT can significantly reduce the unnecessary radiation dose to the carotid arteries compared with conventional 3DCRT technique while maintaining target volume coverage. CS-IMRT technique can be considered for breast cancer patient with high risk of atherosclerosis.  相似文献   

18.
BackgroundThe most common site of recurrence of prostate cancer after definite radiation therapy is the dominant intraprostatic lesion (DIL). This study aimed to investigate the feasibility and safety of definite volumetric modulated arc therapy (VMAT) with simultaneous integrated boost (SIB) to the DIL in patients with unfavorable intermediate to high-risk prostate cancer.Materials and methodsIn this prospective uncontrolled clinical trial, patients were delivered VMAT at a dose of 87.75 Gy in 39 fractions or 70 Gy in 20 fractions to the DIL in combination with androgen deprivation therapy. Genitourinary (GU) and rectal toxicity, International Prostate Symptom Score (IPSS) and IPSS quality of life (IPSS-QOL) score were collected.ResultsForty-five patients with a median follow-up of 20 months were analyzed. The cumulative incidence of acute grade ≥ 2 GU and rectal toxicity was 33.1% and 9.5%, respectively. Regarding late toxicity, the cumulative incidence of grade ≥ 2 GU and rectal toxicity was 12.6% and 2.8%, respectively. During treatment, the mean increase of IPSS was +7.4 ± 4.2 and the mean increase of IPSS-QOL was +1.7 ± 1.3. However, both IPSS and IPSS-QOL scores returned to their baseline levels by 3-months post-treatment. No significant correlation between baseline characteristics and grade ≥ 2 GU or rectal toxicity was found.ConclusionFocal SIB to the DIL of ≥ 90 Gy EQD2 in unfavorable intermediate to high-risk prostate cancer patients resulted in tolerable toxicity profiles. The mean IPSS and IPSS-QOL scores both worsened during treatment; however, both scores returned to baseline level by 3 months after treatment.  相似文献   

19.
BackgroundThe present research was aimed to compare the toxicity and effectiveness of conventional fractionated radiotherapy versus hypo-fractionated radiotherapy in breast cancer utilizing a radiobiological model.Materials and methodsThirty-five left-sided breast cancer patients without involvement of the supraclavicular and axillary lymph nodes (with the nodal stage of N0) that had been treated with conventional or hypo-fractionated were incorporated in this study. A radiobiological model was performed to foretell normal tissue complication probability (NTCP) and tumor control probability (TCP).ResultsThe data represented that TCP values for conventional and hypo-fractionated regimens were 99.16 ± 0.09 and 95.96 ± 0.48, respectively (p = 0.00). Moreover, the NTCP values of the lung for conventional and hypo-fractionated treatment were 0.024 versus 0.13 (p = 0.035), respectively. Also, NTCP values of the heart were equal to zero for both regimens.ConclusionIn summary, hypo-fractionated regimens had comparable efficacy to conventional fraction radiation therapy in the case of dosimetry parameters for patients who had left breast cancer. But, utilizing the radiobiological model, conventional fractionated regimens presented better results compared to hypo-fractionated regimens.  相似文献   

20.
PurposeThis study evaluated the dose distribution and homogeneity of four different types of intensity-modulated radiotherapy (IMRT) in comparison with standard wedged tangential-beam three-dimensional conformal radiotherapy (3DCRT) of the left breast in patients who had undergone lumpectomy.Materials and methodsFive radiotherapy treatment plans, including 3DCRT, forward-planned IMRT (for-IMRT), inverse IMRT (inv-IMRT), helical tomotherapy (HT) and volumetric-modulated arc therapy (VMAT), were created for 15 consecutive patients.ResultsAll modalities presented similar target coverage. Target max doses were reduced with for-IMRT compared to 3DCRT, and these doses were further reduced with inv-IMRT and HT. HT resulted in the lowest max doses delivered to the heart, left anterior descending artery (LAD), and ipsilateral lung, but had higher mean, max, and low doses delivered to contralateral breast. HT resulted in increased low doses to a large volume of healthy tissue. Compared to other techniques, all inverse-planned modalities significantly improved conformity number; however, VMAT had worse homogeneity. The for-IMRT plan significantly lowered monitor unit (MU) compared to the inverse-planned techniques.ConclusionAll modalities evaluated provide adequate coverage of the whole breast. For-IMRT improves target homogeneity compared with 3DCRT, but to a lesser degree than the inverse-planned inv-IMRT and HT. HT decreases the ipsilateral OAR volumes receiving higher and mean doses with an increase in the volumes receiving low doses, which is known to lead to an increased rate of radiation-induced secondary malignancies.  相似文献   