首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC–MS) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC–MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC–MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC–MS, and iTRAQ®–LC–MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27 ± 5.22, 21.18 ± 10.94, and 18.34 ± 14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39 ± 5.35, 6.23 ± 3.84, and 35.37 ± 29.42. Both GC–MS and iTRAQ®–LC–MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.  相似文献   

2.
3.
Oxidative stress-related damage to the DNA macromolecule produces a multitude of lesions that are implicated in mutagenesis, carcinogenesis, reproductive cell death, and aging. Many of these lesions have been studied and characterized by various techniques. Of the techniques that are available, the comet assay, HPLC-EC, GC-MS, HPLC-MS, and especially HPLC-MS/MS remain the most widely used and have provided invaluable information on these lesions. However, accurate measurement of DNA damage has been a matter of debate. In particular, there have been reports of artifactual oxidation leading to erroneously high damage estimates. Further, most of these techniques measure the end product of a sequence of events and thus provide only limited information on the initial radical mechanism. We report here a qualitative measurement of DNA damage induced by a Cu(II)–H2O2 oxidizing system using immuno-spin trapping (IST) with electron paramagnetic resonance (EPR), MS, and MS/MS. The radical generated is trapped by DMPO immediately upon formation. The DMPO adduct formed is initially EPR active but subsequently is oxidized to the stable nitrone, which can then be detected by IST and further characterized by MS and MS/MS.  相似文献   

4.
5.
6.
The application of 7-ethyl-10-hydroxycamptothecin (SN-38) in cancer treatment is limited by its low solubility. This study is to develop a liposome-entrapped formulation of SN-38 (LE-SN38) to solve the obstacle and to evaluate its pharmacokinetic profile in dogs and tissue distribution in mice. LE-SN38 which is more likely to be suitable for large-scale production was prepared by the carrier-deposition method. An UPLC–MS/MS method was used to determinate the concentration of SN-38 in this study. LE-SN38 was cleared rapidly from dog plasma within 1 h, and the AUC0?∞ values of three dosages of LE-SN38 indicated an apparent dose-dependent manner. As for the distribution study, the peak of SN-38 levels in most tissues were detected within 10 min after LE-SN38 administration. In addition, concentration of SN-38 in most tissues except kidney and heart in LE-SN38 group was higher than that in irinotecan hydrochloride (CPT-11) group generally, whereas the administrated CPT-11 had 20 times dosage compared to LE-SN38. LE-SN38 was rapidly eliminated from dog plasma and manifested linear dynamics in dose range of 0.411–1.644 mg/kg. The distribution behavior of SN-38 is altered in a liposome-based delivery system. At the same time, LE-SN38 has lower toxicity compared to CPT-11 in some degree.  相似文献   

7.
A rapid, sensitive and specific method for the determination of cepharanthine in human plasma using high performance liquid chromatography coupled with tandem mass spectrometry (HPLC–MS/MS) was described. Cepharanthine and the internal standard (I.S.), telmisartan, were extracted from human plasma by methanol to precipitate the protein. A centrifuged upper layer was then evaporated and reconstituted with 100 μL methanol. Chromatographic separation was performed on an AGILENT XDB-C8 column (150 mm × 2.1 mm, 5.0 μm, Agilent, USA) using a gradient mobile phase with 1 mmol/L ammonium acetate in water with 0.05% formic acid and methanol. Detection and quantitation was performed by MS/MS using electrospray ionization (ESI) and multiple reaction monitoring (MRM) in the positive ion mode. The most intense [M+H]+ MRM transition of cepharanthine at m/z 607.3 → 365.3 was used for quantitation and the transition at m/z 515.5 → 276.4 was used to monitor telmisartan. The calibration curve was linear within the concentration range of 0.5–200.0 ng/mL (= 0.9994). The limit of quantification (LOQ) was 0.5 ng/mL. The extraction recovery was above 81.1%. The accuracy was higher than 92.3%. The intra- and inter-day precisions were less than 9.66%. The method was accurate, sensitive and simple and was successfully applied to a pharmacokinetic study after single intravenous administration of 50 mg cepharanthine in 12 healthy Chinese volunteers.  相似文献   

8.
Isotope dilution is currently the most accurate technique in humans to determine vitamin A status and bioavailability/bioconversion of provitamin A carotenoids such as β-carotene. However, limits of MS detection, coupled with extensive isolation procedures, have hindered investigations of physiologically-relevant doses of stable isotopes in large intervention trials. Here, a sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) analytical method was developed to study the plasma response from coadministered oral doses of 2 mg [13C10]β-carotene and 1 mg [13C10]retinyl acetate in human subjects over a 2 week period. A reverse phase C18 column and binary mobile phase solvent system separated β-carotene, retinol, retinyl acetate, retinyl linoleate, retinyl palmitate/retinyl oleate, and retinyl stearate within a 7 min run time. Selected reaction monitoring of analytes was performed under atmospheric pressure chemical ionization in positive mode at m/z 537→321 and m/z 269→93 for respective [12C]β-carotene and [12C] retinoids; m/z 547→330 and m/z 274→98 for [13C10]β-carotene and [13C5] cleavage products; and m/z 279→100 for metabolites of [13C10]retinyl acetate. A single one-phase solvent extraction, with no saponification or purification steps, left retinyl esters intact for determination of intestinally-derived retinol in chylomicrons versus retinol from the liver bound to retinol binding protein. Coadministration of [13C10]retinyl acetate with [13C10]β-carotene not only acts as a reference dose for inter-individual variations in absorption and chylomicron clearance rates, but also allows for simultaneous determination of an individual''s vitamin A status.  相似文献   

9.
Protein methylation and acetylation play important roles in biological processes, and misregulation of these modifications is involved in various diseases. Therefore, it is critical to understand the activities of the enzymes responsible for these modifications. Herein we describe a sensitive method for ratiometric quantification of methylated and acetylated peptides via MALDI–MS by direct spotting of enzymatic methylation and acetylation reaction mixtures without tedious purification procedures. The quantifiable detection limit for peptides with our method is approximately 10 fmol. This is achieved by increasing the signal-to-noise ratio through the addition of NH4H2PO4 to the matrix solution and reduction of the matrix α-cyanohydroxycinnamic acid concentration to 2 mg/ml. We have demonstrated the application of this method in enzyme kinetic analysis and inhibition studies. The unique feature of this method is the simultaneous quantification of multiple peptide species for investigation of processivity mechanisms. Its wide buffer compatibility makes it possible to be adapted to investigate the activity of any protein methyltransferase or acetyltransferase.  相似文献   

10.

Introduction

Current computational tools for gas chromatography—mass spectrometry (GC–MS) metabolomics profiling do not focus on metabolite identification, that still remains as the entire workflow bottleneck and it relies on manual data reviewing. Metabolomics advent has fostered the development of public metabolite repositories containing mass spectra and retention indices, two orthogonal properties needed for metabolite identification. Such libraries can be used for library-driven compound profiling of large datasets produced in metabolomics, a complementary approach to current GC–MS non-targeted data analysis solutions that can eventually help to assess metabolite identities more efficiently.

Results

This paper introduces Baitmet, an integrated open-source computational tool written in R enclosing a complete workflow to perform high-throughput library-driven GC–MS profiling in complex samples. Baitmet capabilities were assayed in a metabolomics study involving 182 human serum samples where a set of 61 metabolites were profiled given a reference library.

Conclusions

Baitmet allows high-throughput and wide scope interrogation on the metabolic composition of complex samples analyzed using GC–MS via freely available spectral data. Baitmet is freely available at http://CRAN.R-project.org/package=baitmet.
  相似文献   

11.
The role of vertebrate-like sex-steroids (testosterone, T, progesterone, P, and 17β-estradiol, E2) in molluscs is still debated, but they could represent potential biomarkers of endocrine disruption. A radioimmunoassay (RIA) and a liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) methods have been developed and compared to measure their levels in a gastropod snail Potamopyrgus antipodarum. Both methods showed a good reproducibility despite the complex matrix and the very low levels of vertebrate-like sex-steroids. Only T and P were detected using the LC–MS/MS method, while the RIA method reached lower detection limits and enabled the detection of all three steroids. Results indicated that T and P were mainly present as unconjugated forms. Both methods were compared in the analysis of snails exposed to waste water treatment plant effluents and led to the same conclusions concerning the modulation of steroids levels. Moreover, they both were in agreement concerning T measurements. On the other hand, LC–MS/MS appeared to be more suitable when analyzing P levels due to a low sensitivity of the RIA method. As E2 was not measured using the LC–MS/MS method because of a higher detection limit compared to the other steroids, the results obtained with the RIA method should be interpreted with caution. LC–MS/MS remains the gold standard for sex-steroid determinations, however a relevant and alternative method based on RIA was developed, requiring fewer organisms. RIA seems a promising method as a screening tool for experimental use, allowing comparison of sex-steroid levels in the mudsnail both in laboratory and in field experiments.  相似文献   

12.
目的:建立二极管阵列高效液相色谱仪和三重四级杆液质联用仪对豆奶中三聚氰胺的测定方法。方法:采用三氯乙酸和乙腈为提取剂、蛋白质为沉淀剂,提取液过净化柱纯化。结果:三重四级杆液质联用法对三聚氰胺的检出限为0-001 5 mg/kg,标准曲线在0-01~0-5 μg/mL范围内,R2为0-999 8,线性良好,再回收率为85 %~89 %,适用于检测低浓度的样品;二极管阵列高效液相色谱法检出限为0-024 mg/kg,标准曲线在0-5~100 μg/mL范围内,R2为0-999 9,线性良好,回收率为83 %~91 %,可以快速地对高浓度样品进行筛查。结论以上两种检测方法结合使用,可检测0-01~100 mg/kg的三聚氰胺含量,极大地拓宽了检测范围。  相似文献   

13.
14.
A high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS–MS) method, using back-flush column-switching was developed for total drug concentrations of ropivacaine in serum and drainage blood in the measuring range 0.1–10 μg/mL. Samples were diluted with internal standard (2H7-ropivacaine) and extraction buffer, centrifuged and injected directly onto a BioTrap 500 MS extraction column. Using a time programmed six-port valve switch, ropivacaine was back-flushed onto a Zorbax SB-Aq analytical column, gradient eluted and finally detected after electro spray ionisation and multiple reaction monitoring (MRM) of the transitions m/z 275 → m/z 126 and m/z 282 → m/z 133 for ropivacaine and 2H7-ropivacaine, respectively. Accuracy (bias-%) was −1.5 to 5.8% and intermediate precision (C.V.) was 1.4–3.1%. The low sample amount required (10 μL), high specificity and short run time (6 min) makes it very suitable for determination of ropivacaine. Using the same methodology as described above and 200 μL ultrafiltrate, the free drug concentrations of ropivacaine in serum could be precisely determined with a C.V. below 3%. The method was used to investigate the safety of reinfusion of drainage blood after knee and hip arthroplasty when ropivacaine (Naropin®) was used for local analgesia. Data for 30 patients are summarised.  相似文献   

15.
l-Homoarginine (hArg) has recently emerged as a novel cardiovascular risk factor and to herald a poor prognosis in heart failure patients. Here, we report on the development and thorough validation of gas chromatography–mass spectrometry (GC–MS) and gas chromatography–tandem mass spectrometry (GC–MS/MS) methods for the quantitative determination of hArg in biological samples, including human plasma, urine and sputum. For plasma and serum samples, ultrafiltrate (10 µL; cutoff, 10 kDa) was used. For urine samples, native urine (10 µL) was used. For sputum, protein precipitation by acetone was performed. hArg is derivatized to its methyl ester tri(N-pentafluoropropionyl) derivative; de novo synthesized trideutero-methyl ester hArg is used as the internal standard (IS). Alternatively, [guanidino-15N2]-arginine can be used as an IS. Quantitative analyses were performed after electron-capture negative-ion chemical ionization by selected-ion monitoring in GC–MS and selected-reaction monitoring in GC–MS/MS. We obtained very similar hArg concentrations by GC–MS and GC–MS/MS, suggesting that GC–MS suffices for accurate and precise quantification of hArg in biological samples. In plasma and serum samples of the same subjects very close hArg concentrations were measured. The plasma-to-serum hArg concentration ratio was determined to be 1.12 ± 0.21 (RSD, 19 %), suggesting that blood anticoagulation is not a major preanalytical concern in hArg analysis. In healthy subjects, the creatinine-corrected urinary excretion of hArg varies considerably (0.18 ± 0.22 µmol/mmol, mean ± SD, n = 19) unlike asymmetric dimethylarginine (ADMA, 2.89 ± 0.89 µmol/mmol). In urine, hArg correlated with ADMA (r = 0.475, P = 0.040); in average, subjects excreted in the urine about 17.5 times more ADMA than hArg. In plasma of healthy humans, the concentration of hArg is of the order of 2 µM. hArg may be a low-abundance constituent of human plasma proteins. The GC–MS and GC-MS/MS methods we report in this article are useful to study the physiology and pathology of hArg in experimental and clinical settings.  相似文献   

16.
Lipid profiling of human plasma by liquid chromatography-electrospray ionization coupled to mass spectrometry (LC–ESI-MS) is being used to identify biomarkers of health, disease, and treatment efficacy. However, there is no consensus on the choice of anticoagulant to perform and compare lipidomic measurements. This study assessed the effect of the anticoagulants citrate, EDTA, and heparin, on eight synthetic and 80 plasma lipids, and compared lipidomic data among anticoagulants. Lipid extraction was affected distinctively by the anticoagulant of choice likely due to the different physico-chemical properties among anticoagulants. Peak areas of seventy endogenous lipids showed significant differences between citrate–heparin and EDTA–heparin comparisons similar to those observed for synthetic lipids. Only ten endogenous lipid species showed comparable peak areas among the three anticoagulants. Correction by a structurally related internal standard only partly eliminated differences among anticoagulants (ANOVA, P value <0.001). However, comparisons among anticoagulants were possible for most endogenous lipids after correction of peak areas by the sum of areas of its lipid class. Our observations indicate that the choice of anticoagulant distinctively impact the peak response of most lipid species by LC–ESI-MS. Lipidomic data from plasma obtained with different anticoagulants should address differences in matrix effects and extraction procedures since ion strength, plasma pH, and different physicochemical properties among anticoagulants influence lipid extraction and LC–ESI-MS analysis.  相似文献   

17.
One of the experimental processes of functional proteomics is the analysis of protein interaction. Here, we review a new analytical platform, BIA–MS, for protein interaction analysis. BIA–MS is an integration of a surface plasmon resonance biosensor for real-time interaction analysis and mass spectrometry for the subsequent identification of interacting molecules.  相似文献   

18.
Drug–drug interactions involving cytochrome P450 (CYP450s) are an important factor for evaluation of a new chemical entity (NCE) in drug development. To evaluate the potential inhibitory effects of a NCE on the pharmacokinetics of a cocktail of representative probes of CYP enzymes (midazolam for CYP3A4, tolbutamide for CYP2C9, omeprazole for CYP2C19 and dextromethorphan for CYP2D6) and the safety and tolerability of the NCE in the presence of probe substrates, a high throughput liquid chromatography/tandem mass spectrometry (LC–MS/MS) method was developed and validated for the simultaneous determination of tolbutamide, omeprazole, midazolam and dextromethorphan in human plasma using tolbutamide-d9, midazolam-d4, (±)-omeprazole-d3, and dextromethorphan-d3 as the internal standards (ISs). Human plasma samples of 50 μL were extracted by a simple protein-precipitation procedure and analyzed using a high performance liquid chromatography electrospray tandem mass spectrometer system. Reversed-phase HPLC separation was achieved with a Hypersil GOLD AQ column (50 mm × 4.6 mm, 5 μm). MS/MS detection was set at mass transitions of 271  172 m/z for tolbutamide, 346  198 m/z for omeprazole, 326  291 m/z for midazolam, 272  171 m/z for dextromethorphan, 280  172 m/z for tolbutamide-d9 (IS), 349  198 m/z for (±)-omeprazole-d3 (IS), 330  295 m/z for midazolam-d4 (IS), and 275  171 m/z for dextromethorphan-d3 (IS) in positive mode. The high throughput LC–MS/MS method was validated for accuracy, precision, sensitivity, stability, recovery, matrix effects, and calibration range. Acceptable intra-run and inter-run assay precision (<10%) and accuracy (<10%) were achieved over a linear range of 50–50,000 ng/mL for tolbutamide, 1–1000 ng/mL for omeprazole, 0.1–100 ng/mL for midazolam and 0.05–50 ng/mL for dextromethorphan in human plasma. Method robustness was demonstrated by the 100% pass rate of 24 incurred sample analysis runs and all of the 50 clinical study samples used for incurred sample reproducibility (ISR) test having met the acceptance criterion (%Diff within 20%). The overall ISR results for all compounds showed that over 95% of the samples had a %Diff of less than 10%. The method is simple, rapid and rugged, and has been applied successfully to sample analysis in support of a drug–drug interaction study.  相似文献   

19.
《Trends in biotechnology》2001,19(10):S28-S33
One of the experimental processes of functional proteomics is the analysis of protein interaction. Here, we review a new analytical platform, BIA–MS, for protein interaction analysis. BIA–MS is an integration of a surface plasmon resonance biosensor for real-time interaction analysis and mass spectrometry for the subsequent identification of interacting molecules.  相似文献   

20.
Determination of estrogens in plasma is important in evaluation of effects of some anticancer drugs, such as aromatase inhibitors. However, as reported previously, high performance liquid chromatography–radio immunoassay (HPLC–RIA) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) with chemical derivatization require complicated sample preparation. In this study, a highly sensitive and simple method for determination of estrone (E1), 17β-estradiol (E2) and estrone 3-sulfate (E1S) in human plasma has been developed. Following diethylether extraction from plasma, analytes were purified by immunosorbents and then determined by LC–MS/MS using electrospray ionization (ESI). Immunosorbents were prepared by immobilization of specific antibodies raised against each analyte onto solid support. Use of selective immunosorbents in sample preparation removed interference in plasma samples that would cause ionization suppression, and markedly improved the sensitivity of LC–MS/MS for these analytes, without derivatization. Calibration curves of each analyte showed good linearity and reproducibility over the range of 0.05–50 pg/injection for E1, 0.2–50 pg/injection for E2 and 0.05–300 pg/injection for E1S, respectively. The mean values of lower limits of quantification (LLOQ) in human plasma corrected by recovery of deuterated estrogens (internal standard, I.S.) were 0.1892 pg/mL for E1, 0.7064 pg/mL for E2 and 0.3333 pg/mL for E1S, respectively. These LLOQ values were comparable to those previous reported using HPLC–RIA and LC–MS/MS. Using this method, the normal levels of three estrogens in healthy female plasma (n = 5) were determined. The mean values of E1, E2 and E1S were 38.0 pg/mL (range 24.8–53.0), 34.3 pg/mL (22.6–46.6) and 786 pg/mL (163–2080), respectively. The immunoaffinity LC–MS/MS described here allows sensitive and accurate quantification of E1, E2 and E1S without laborious sample preparation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号