首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of the present study was to evaluate the viability of a relationship between the temporal activation pattern of parts of the erector spinae muscle and endurance. Seven subjects performed intermittent isometric contractions [4 s at 7007o maximal voluntary contraction (MVC), 2 s rest] until exhaustion, during which the electromyographical (EMG) activity of the multifidus, iliocostalis thoracis and longissimus muscle segments was recorded. Endurance was defined as the time until exhaustion. Subjects were divided into a high and a low endurance group. The high endurance group showed significantly more variability of EMG amplitude over succeeding contractions. This group demonstrated significantly more alternations of EMG activity between parts of the muscle also. Variability of the EMG amplitude within the contractions did not differ between the groups, nor did MVC. The results indicated that alternating activity between different parts of the erector spinae muscle may function to postpone exhaustion of this muscle as a whole.  相似文献   

2.
The present study examined respiratory muscle endurance and the magnitude of the sense of effort during inspiratory threshold loading following a dose of caffeine (600 mg) previously observed to increase diaphragm strength. Experiments were performed on 12 normal subjects. Respiratory muscle endurance at a given level of load was assessed from the time of exhaustion and from the time course of the change in the power spectrum (centroid frequency) of the diaphragm electromyogram (EMG). The intensity of the sense of effort during loaded breathing was evaluated using a category (Borg) scale. Increasingly severe loads were associated with more rapid onset of fatigue. At a given load, caffeine prolonged the time to exhaustion and decreased the rate of fall of the centroid frequency of the diaphragm EMG. Caffeine also decreased the sense of effort during loaded breathing in 9 of 11 subjects. Changes in respiratory muscle endurance after caffeine administration were not explained by changes in the pressure-time index of the respiratory muscles or the pattern of thoracoabdominal movement. We conclude that caffeine enhances inspiratory muscle endurance, while concomitantly reducing the sense of effort associated with fatiguing inspiratory muscle contractions.  相似文献   

3.
Five men performed submaximal isometric, concentric or eccentric contractions until exhaustion with the left arm elbow flexors at respectively 50%, 40% and 40% of the prefatigued maximal voluntary contraction force (MVC). Subsequently, and at regular intervals, the surface electromyogram (EMG) during 30-s isometric test contractions at 40% of the prefatigued MVC and the muscle performance parameters (MVC and the endurance time of an isometric endurance test at 40% prefatigued MVC) were recorded. Large differences in the surface EMG response were found after isometric or concentric exercise on the one hand and eccentric exercise on the other. Eccentric exercise evoked in two of the three EMG parameters [the EMG amplitude (root mean square) and the rate of shift of the EMG mean power frequency (MPF)] the greatest (P less than 0.001) and longest lasting (up to 7 days) response. The EMG response after isometric or concentric exercise was smaller and of shorter duration (1-2 days). The third EMG parameter, the initial MPF, had already returned to its prefatigued value at the time of the first measurement, 0.75 h after exercise. The responses of EMG amplitude and of rate of MPF shift were similar to the responses observed in the muscle performance parameters (MVC and the endurance time). Complaints of muscle soreness were most frequent and severe after the eccentric contractions. Thus, eccentric exercise evoked the greatest and longest lasting response both in the surface EMG signal and in the muscle performance parameters.  相似文献   

4.
Findings from five separate studies of EMG changes and muscle fatigue during prolonged low-level static contractions are summarized, and the possible mechanisms behind the changes are briefly discussed. Sustained static contractions (10%, 7% and 5% MVC) of up to 1 h duration were performed by finger flexors, elbow flexors and extensors, and knee extensors. In one experiment, intermittent static arm pulling (triceps) (10 s contraction and 5 s rest, average work load 14% and 10% MVC) was performed for 7 h. The endurance time for the sustained contractions was around one hour for 10% MVC, and it was shown--all in all--that the concept of "indefinite" endurance times at contractions below 15-20% MVC cannot be maintained. After 5% MVC sustained contractions for one hour a 12% reduction in MVC was seen, and significant increases in EMG amplitude and decreases in the mean spectral frequency of the EMG-power spectrum were found. Marked differences were also seen in the EMG changes in the elbow flexors and extensors, and transcutaneous electrical stimulation of the knee extensors showed that low frequency fatigue was present after the contraction. With intermittent contractions similar changes in the EMG parameters were seen after 2-3 h of contractions at 14% MVC. On average, during contractions of 10% MVC no EMG changes were detected. Increased extracellular potassium concentration in the contracting muscles is suggested as a possible explanation of these findings.  相似文献   

5.
The physiological response to continuous and intermittent handgrip exercise was evaluated. Three experiments were performed until exhaustion at 25% of maximal voluntary contraction (MVC): experiment 1, continuous handgrip (CH) (n = 8); experiment 2, intermittent handgrip with 10-s rest pause every 3 min (IH) (n = 8); and experiment 3, as IH but with electrical stimulation (ES) of the forearm extensors in the pauses (IHES) (n = 4). Before, during, and after exercise, recordings were made of heart rate (HR), arterial blood pressure (BP), exercising forearm blood flow, and concentrations of potassium [K+] and lactate [La-] in venous blood from both arms. The electromyogram (EMG) of the exercising forearm extensors and perceived exertion were monitored during exercise. Before and up to 24 h after exercise, observations were made of MVC, of force response to electrical stimulation and of the EMG response to a 10-s test contraction (handgrip) at 25% of the initial MVC. Maximal endurance time (tlim) was significantly longer in IH (23.1 min) than in CH (16.2 min). The ES had no significant effect on tlim. During exercise, no significant differences were seen between CH and IH in blood flow, venous [K+] and [La-], or EMG response. The HR and BP increased at the same rate in CH and IH but, because of the longer duration of IH, the levels at exhaustion were higher in this protocol. The subjects reported less subjective fatigue in IH. During recovery, return to normal MVC was slower after CH (24 h) than after IH (4 h).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
The purpose of this study was to determine test-retest reliability for median frequency (MDF) and amplitude of surface EMG during sustained fatiguing contractions of the quadriceps. Twenty-two healthy subjects (11 males and 11 females) were tested on two days held one week apart. Surface EMG was recorded from rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM) during sustained isometric contractions at 80% and 20% of maximal voluntary contraction (MVC) held to exhaustion. Quadriceps fatigue was described using four measures for both MDF and amplitude of EMG: initial, final, normalized final and slope. For both MDF and amplitude, the initial, final and normalized EMG showed moderate to high reliability for all three muscle groups at both contraction levels (ICC=0.59-0.88 for MDF; ICC=0.58-0.99 for amplitude). Slope of MDF and amplitude was associated with a large degree of variability and low ICCs for the 80% but not the 20% MVC. MDF and amplitude of EMG during sustained contractions of the quadriceps are reproducible; normalized final values of MDF and amplitude show better reliability than slope.  相似文献   

7.
8.
IntroductionIn a previous paper, standard surface electromyographic (EMG) indices of muscle fatigue, which are based on the lowering of the median or mean frequencies of the EMG power spectrum in time, were applied during an intermittent absolute endurance test and were evaluated relative to criterion validity and test–retest reliability. The aims of this study were to assess mechanical and alternative EMG correlates of muscle fatigue.MethodsHealthy subjects (44 males and 29 females; age: 20–55 yrs) performed three maximal voluntary contractions (MVC) and an endurance test while standing in a static dynamometer. Surface EMG signals were collected from four pairs of back muscles (multifidus at the L5 level, iliocostalis lumborum at L3, and longissimus at L1 and T10). The test, assessing absolute endurance (90 N m torque), consisted of performing an intermittent extension task to exhaustion. Strength was defined as the peak MVC whereas our endurance criterion was defined as the time to reach exhaustion (Tend) during the endurance test. Mechanical indices quantifying physiological tremor and steadiness were computed from the dynamometer signals (L5/S1 extension moments) along with EMG indices presumably sensitive to variable load sharing between back muscle synergists during the endurance test.ResultsMechanical indices were significantly correlated to Tend (r range: −0.47 to –0.53) but showed deceiving reliability results. Conversely, the EMG indices were correlated to Tend (r range: −0.43 to –0.63) with some of them particularly correlated to Strength (r =  0.72 to –0.81). In addition, their reliability results were acceptable (intra-class correlation coefficient >0.75; standard error of measurement <10% of the mean) in many cases. Finally, several analyses substantiated their physiological relevance. These findings imply that these new EMG indices could be used to predict absolute endurance as well as strength with the use of a single intermittent and time-limited (5–10 min) absolute endurance test, a practical way to assess the back capacity of chronic low back pain subjects.  相似文献   

9.
IntroductionBack muscle capacity is impaired in chronic low back pain patients but no motivation-free test exists to measure it. The aims of this study were to assess the reliability and criterion validity of electromyographic indices of muscle fatigue during an intermittent absolute endurance test.MethodsHealthy subjects (44 males and 29 females; age: 20–55 yrs) performed three maximal voluntary contractions (MVC) and a fatigue test while standing in a static dynamometer. Surface EMG signals were collected from four pairs of back muscles (multifidus at the L5 level, iliocostalis lumborum at L3, and longissimus at L1 and T10). The fatigue test, assessing absolute endurance (90-Nm torque), consisted in performing an intermittent extension task to exhaustion. Strength was defined as the peak MVC whereas our endurance criterion was defined as the time to reach exhaustion (Tend) during the fatigue test. From the first five min (females) or ten min (males) of EMG data, frequency and time-frequency domain analyses were applied to compute various spectral indices of muscle fatigue.ResultsThe EMG indices were more reliable when computed from the time-frequency domain than when computed from the frequency domain, but showed comparable correlation results (criterion validity) with Tend and Strength. Some EMG indices reached moderate to good correlation (range: 0.64–0.69) with Tend, lower correlations (range: 0.39–0.55) with Strength, and good to excellent between-day test-retest reliability results (intra-class correlation range: 0.75–0.83). The quantification of the spectral content more locally in different frequency bands of the power spectrum was less valid and reliable than the indices computed from the entire power spectrum. Differences observed among muscles were interpreted in light of specific neuromuscular activation levels that were observed during the endurance test. These findings supported the use of an intermittent and time-limited (5–10 min) absolute endurance test, that is a practical way to assess the back capacity of chronic low back pain subjects, to assess absolute endurance as well as strength with the use of electromyographic indices of muscle fatigue.  相似文献   

10.
In 5 healthy male subjects the changes in muscle fibre conduction velocity, mean power frequency, mean EMG voltage, and force in the quadriceps were measured during submaximal fatiguing contractions, ranging from 60 to 100% of maximum force. Surface EMG was recorded from vastus lateralis. The analysis was divided into 2 parts - before and after force had begun to decline (endurance point). The conduction velocity and mean power frequency declined less before the endurance point than after this point. For all forces, the mean EMG voltage increased up to the endurance point. After the endurance point, the effect of fatigue had a decreasing influence on mean EMG voltage.  相似文献   

11.
We investigated the effects of caffeine mouth rinse on endurance performance, muscle recruitment (i.e., electromyographic activity of the vastus lateralis and rectus femoris), rating of perceived effort and heart rate. Twelve physically-active healthy men cycled at 80% of their respiratory compensation point until task failure. The participants rinsed their mouths for 10 seconds with placebo (PLA, 25 mL of a solution composed of non-caloric mint essence) or caffeine (CAF, 25 mL of 1.2% of anhydrous caffeine concentration with non-caloric mint essence) every 15 minutes of exercise. Time until exhaustion increased 17% (effect size = 0.70) in CAF compared to PLA (p = 0.04). The wavebands of low-frequency electromyographic activity (EMG) of the vastus lateralis and rectus femoris was lower in CAF group than PLA at 50% of the time until exhaustion (p = 0.04). The global EMG signal was lower in CAF group than PLA at 100% of the time until exhaustion (p = 0.001). The rating of perceived effort pooled was higher in CAF mouth rinse (p = 0.001) than PLA group. No effect was found on the heart rate between the groups (p > 0.05). Caffeine mouth rinse increases endurance performance, rating of perceived effort and decreases muscle activity during a moderate-intensity exercise.  相似文献   

12.
Intramuscular pressure (IMP) and electromyography (EMG) mirror muscle force in the nonfatigued muscle during static contractions. The present study explores whether the constant IMP-EMG relationship with increased force may be extended to dynamic contractions and to fatigued muscle. IMP and EMG were recorded from shoulder muscles in three sessions: 1). brief static arm abductions at angles from 0 to 90 degrees, with and without 1 kg in the hands; 2). dynamic arm abductions at angular velocities from 9 to 90 degrees /s, with and without 1 kg in the hands; and 3). prolonged static arm abduction at 30 degrees for 30 min followed by recovery. IMP and EMG increased in parallel with increasing shoulder torque during brief static tasks. During dynamic contractions, peak IMP and EMG increased to values higher than those during static contractions, and EMG, but not IMP, increased significantly with speed of abduction. In the nonfatigued supraspinatus muscle, a linear relationship was found between IMP and EMG; in contrast, during fatigue and recovery, significant timewise changes of the IMP-to-EMG ratio occurred. The results indicate that IMP should be included along with EMG when mechanical load sharing between muscles is evaluated during dynamic and fatiguing contractions.  相似文献   

13.
The relative roles of motor unit firing rate modulation and recruitment were evaluated when individuals with cervical spinal cord injury (SCI) and able-bodied controls performed a brief (6 s), 50% maximal voluntary contraction (50% MVC; target contraction) of triceps brachii every 10 s until it required maximal effort to achieve the target force. Mean (+/-SD) endurance times for SCI and control subjects were 34+/-26 and 15+/-5 min, respectively, at which point significant reductions in maximal triceps force had occurred. Twitch occlusion analysis in controls indicated that force declines resulted largely from peripheral contractile failure. In SCI subjects, triceps surface EMG and motor unit potential amplitude declined in parallel suggesting failure at axon branch points and/or alterations in muscle membrane properties. The force of low threshold units, measured by spike-triggered averaging, declined in SCI but not control subjects, suggesting that higher threshold units fatigued in controls. Central fatigue was also obvious after SCI. Mean (+/-SD) MVC motor unit firing rates declined significantly with fatigue for control (24.6+/-7.1 to 17.3+/-5.1Hz), but not SCI subjects (25.9+/-12.7 to 20.1+/-9.7Hz). Unit firing rates were unchanged during target contractions for each subject group, but with the MVC rate decreases, units of SCI and control subjects were activated intensely at endurance time (88% and 99% MVC rates, respectively). New unit recruitment also maintained the target contractions although it was limited after SCI because many descending inputs to triceps motoneurons were disrupted. This resulted in sparse EMG, even during MVCs, but allowed the same unit to be recorded throughout. These EMG data showed that both unit recruitment and rate modulation were important for maintaining force during repeated submaximal intermittent contractions of triceps brachii muscles performed by SCI subjects. Similar results were found for control subjects. Muscles weakened by SCI may therefore provide a useful model in which to directly study motor unit rate modulation and recruitment during weak or strong voluntary contractions.  相似文献   

14.
The purpose of the present investigation is to use surface interference EMG recorded by branched electrodes for assessment of muscle fatigue during sustained voluntary isometric contractions at different levels. Level-trigger averaging and turn/amplitude analysis have been applied. The conduction velocity (CV) of excitation was calculated from the time shift of the negative peaks of the averaged potentials (AvPs) derived from the EMG recorded by two electrodes placed along the muscle fibers. The recruitment of new motor units affects the negative amplitude (NA) of AvPs, the number of turns per second and the mean amplitude of turns in a different way depending on the level of sustained contractions. In contrast, the CV declined at all levels of sustained contractions and was the most appropriate parameter for the muscle fatigue assessment. There was a good correlation between CV decrease and torque reduction during sustained maximal efforts. The level-trigger averaging technique of the interference EMG recorded by surface branched electrodes is easy and non-invasive, thus being very convenient for routine application.  相似文献   

15.
We determined the repeatability and correlations between force, endurance and muscle activity during isometric contractions over three years. Twenty-six subjects, with and without complaints of the shoulder and neck, performed standardized maximal and submaximal shoulder-abduction contractions and wrist extension-contractions at yearly intervals from 1997 to 1999. Peak forces developed during maximal contraction and the endurance times of submaximal contractions during shoulder abduction and wrist extension were measured. Electromyography (EMG) of muscle activity was recorded bilaterally from the upper trapezius, middle deltoid, and forearm extensor muscles. Root mean square EMG amplitudes were calculated. We found statistically significant associations between peak forces developed during wrist extension and shoulder abduction, and between endurance times of submaximal wrist extension and shoulder abduction. No statistically significant changes in peak force and EMG(peak) were found over the measurement years. The responses were not statistically significantly influenced by gender, or neck and shoulder pain. However, we observed considerable intra-individual variation in the inter-year measurements particularly for the responses to submaximal contraction. Such large variations represent a challenge when attempting to use the responses to interpret the effects of therapies.  相似文献   

16.
Fourteen young subjects (7 men and 7 women) performed a fatiguing isometric contraction with the elbow flexor muscles at 20% of maximal voluntary contraction (MVC) force on three occasions. Endurance time for session 3 [1,718 +/- 1,189 (SD) s] was longer than for session 1 (1,225 +/- 683 s) and session 2 (1,410 +/- 977 s). Five men and four women increased endurance time between session 1 and 3 by 60 +/- 28% (responders), whereas two men and three women did not (-3 +/- 11%; nonresponders). The MVC force was similar for the responders and nonresponders, both before and after the fatiguing contraction. Fatiguing contractions were characterized by an increase in the electromyogram (EMG) amplitude and number of bursts during the fatiguing contractions. The responders achieved a similar level of EMG at exhaustion but a reduced rate of increase in the EMG across sessions. The rate of increase in EMG across sessions declined for the nonresponders, but it remained greater than that of the responders. The increase in burst rate during the contractions declined across sessions with a negative relation between burst rate and endurance time (r = -0.42). Normalized force fluctuations increased during the fatiguing contractions, and there was a positive relation (r = 0.60) between the force fluctuations and burst rate. Changes in mean arterial pressure and heart rate during the fatiguing contraction were similar for the responders and nonresponders across the three sessions. The results indicate that those subjects who increased the endurance time of a submaximal contraction across three sessions did so by altering the level and pattern of muscle activation.  相似文献   

17.
We investigated the firing rate of motor units in the vastus lateralis muscle in five healthy young men (mean = 21.4 yr, SD = 0.9) during a sequence of isometric constant-torque contractions repeated to exhaustion. The contractions were sustained at 20% of the maximal voluntary level, measured at the beginning of the test sequence. Electromyographic (EMG) signals were recorded via quadrifilar fine-wire electrodes and subsequently decomposed into their constituent motor unit action potentials to obtain the motor unit firing times. In addition, we measured the whole muscle mechanical properties during the fatigue task using electrical stimulation. The firing rate of motor units first decreased within the first 10-20% of the endurance time of the contractions and then increased. The firing rate increase was accompanied by recruitment of additional motor units as the force output remained constant. The elicited twitch and tetanic torque responses first increased and then decreased. The two processes modulated in a complementary fashion at the same time. Our data suggest that, when the vastus lateralis muscle is activated to maintain a constant torque output, its motoneuron pool receives a net excitatory drive that first decreases to compensate for the short-lived potentiation of the muscle force twitch and then increases to compensate for the diminution of the force twitch. The underlying inverse relationship between the firing rate and the recruitment threshold that has been reported for nonfatigued contractions is maintained. We, therefore, conclude that the central nervous system control of vastus lateralis motor units remains invariant during fatigue in submaximal isometric isotonic contractions.  相似文献   

18.
During sustained maximal voluntary contractions (MVCs), most fatigue occurs within the muscle, but some occurs because voluntary activation of the muscle declines (central fatigue), and some of this reflects suboptimal output from the motor cortex (supraspinal fatigue). This study examines whether supraspinal fatigue occurs during a sustained submaximal contraction of 5% MVC. Eight subjects sustained an isometric elbow flexion of 5% MVC for 70 min. Brief MVCs were performed every 3 min, with stimulation of the motor point, motor cortex, and brachial plexus. Perceived effort and pain, elbow flexion torque, and surface EMGs from biceps and brachioradialis were recorded. During the sustained 5% contraction, perceived effort increased from 0.5 to 3.9 (out of 10), and elbow flexor EMG increased steadily by approximately 60-80%. Torque during brief MVCs fell to 72% of control values, while both the resting twitch and EMG declined progressively. Thus the sustained weak contraction caused fatigue, some of which was due to peripheral mechanisms. Voluntary activation measured by motor point and motor cortex stimulation methods fell to 90% and 80%, respectively. Thus some of the fatigue was central. Calculations based on the fall in voluntary activation measured with cortical stimulation indicate that about two-thirds of the fatigue was due to supraspinal mechanisms. Therefore, sustained performance of a very low-force contraction produces a progressive inability to drive the motor cortex optimally during brief MVCs. The effect of central fatigue on performance of the weak contraction is less clear, but it may contribute to the increase in perceived effort.  相似文献   

19.
Endurance and changes in electromyogram (EMG) power spectra were investigated during a fatiguing static contraction at 50% of the maximum EMG amplitude in two jaw-elevator muscles (masseter and temporalis) and five facial muscles (frontalis, corrugator supercilii, zygomaticus major, orbicularis oris, and buccinator). Relatively high endurance was found in orbicularis oris, frontalis, and corrugator supercilii muscles; intermediate endurance was found in zygomaticus major, buccinator, and temporalis muscles; and low endurance was found in the masseter muscle. The last muscle showed a relatively fast linear decrease of the median frequency of the power spectrum. The other muscles showed a much slower, exponential decrease. The median frequency appeared to reflect reliably the changes in the shape of the power spectra during fatigue. Large differences between the shape of power spectra of different muscles in the unfatigued state were found. These, however, were unrelated to endurance and degree of spectral shift during fatigue.  相似文献   

20.
The clinical application of EMG requires that the recorded signal is representative of the muscle of interest and is not contaminated with signals from adjacent muscles. Some authors report that surface EMG is not suitable for obtaining information on a single muscle but rather reflects muscle group function [J. Perry, C.S. Easterday, D.J. Antonelli, Surface versus intramuscular electrodes for electromyography of superficial and deep muscles. Physical Therapy 61 (1981) 7–15]. Other authors report however, that surface EMG is adequate to determine individual muscle function, once guidelines pertaining to data acquisition are followed [D.A. Winter, A.J. Fuglevand, S.E. Archer. Cross-talk in surface electromyography: theoretical and practical estimates. Journal of Electromyography and Kinesiology 4 (1994) 15–26]. The aim of this study was to determine whether surface EMG was suitable for monitoring rectus femoris (RF) activity during static contractions. Five healthy subjects, having given written informed consent, participated in this trial. Surface and fine wire EMG from the rectus femoris and the vastus lateralis (VL) muscles were recorded simultaneously during a protocol of static contractions consisting of knee extensions and hip flexions. Ratios were used to quantify the relationship between the surface EMG amplitude value and the fine wire EMG amplitude value for the same contraction. The results showed that hip flexion contractions elicited RF activation only and that knee extension contractions elicited fine wire activity in VL only. When the relationship between RF surface and RF fine wire electrodes was compared for hip flexion and knee extension contractions, it was observed that for all subjects, there was a tendency for increased RF surface activity in the absence of RF fine wire activity during knee extensions. It was concluded that the activity recorded by the RF surface electrode arrangement during knee extension consisted of EMG from the vastii, i.e., cross-talk and that vastus intermedius was the most likely origin of the erroneous signal. Therefore it is concluded that for accurate EMG information from RF, fine wire electrodes are necessary during a range of static contractions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号