首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A gas chromatographic—mass spectrometric method for the determination of cobalt in biological materials employing stable enriched 62Ni as an internal standard and using lithium bis(trifluoroethyl)dithiocarbamate as a chelating agent is described. The method involves the addition of a known amount (1 μg) of 62Ni to the sample, the formation of the chelate and the determination by selected-ion monitoring of the m/z ratio, which corresponds to . No appreciable memory effect was observed, and an acceptable dynamic range of 100 was found. There was good agreement between the cobalt concentration values determined by gas chromatography—mass spectrometry and electrothermal atomic absorption spectrometry. The present method has high sensitivity and can be used for the quantitation of cobalt at concentrations as low as 1 μg/l. The use of enriched 62Ni circumvents the problem caused by endogenous nickel and simultaneously provides data on the nickel concentration in the biological sample without any additional experimental effort.  相似文献   

2.
A sensitive gas chromatographic method for the determination of cyclophosphamide in urine is presented. After liquid—liquid extraction with diethyl ether and derivatization with trifluoroacetic anhydride, cyclophosphamide was identified and quantified with mass spectrometry. The method is suitable for the determination of cyclophosphamide at concentrations of more than 0.25 ng/ml, which enables the uptake of cyclophosphamide during occupational activities, such as the preparation and administration of antineoplastic agents in hospitals, to be measured. Simple preparation makes the method appropriate for routine analysis.  相似文献   

3.
4.
A quantitative gas chromatographic—mass spectrometric assay was developed for the determination of phenelzine in human plasma. Phenelzine, in aqueous solution or in plasma reacts at room temperature with pentafluorobenzaldehyde to form quantitatively a hydrazone derivative. The derivative has good gas chromatographic characteristics. The assay utilizes selected ion monitoring in a gas chromatographic effluent, the molecular ion generated by electron impact ionization of phenelzine derivative. Phenelzine-d7 was synthesized and used as an internal standard. The assay can measure 2 ng/ml of the drug with about 10% precision.The method was used for the determination of steady state levels of phenelzine in the plasma of patients taking a therapeutic dose of the drug.  相似文献   

5.
JH imple and reliable method for the determination of ketone body turnover in vivo using a primed, continuous infusion of [3,4-13C2]acetoacetate is described. Mole percent enrichment of beta-[13C2]hydroxybutyrate and [13C2]acetoacetate is determined by gas chromatography/mass spectrometry using electron-impact ionization and selected ion monitoring. Ketone body flux data are provided from preliminary dog experiments. The method is readily applicable to the study of ketone body metabolism in both laboratory animals and humans.  相似文献   

6.
A gas chromatographic—mass spectrometric method was developed to determine eperisone hydrochloride, 4′-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2–40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml, the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.  相似文献   

7.
8.
A highly specific and sensitive method for the determination of the anti-ulcer drug geranylgeranylacetone (GGA) in human serum is described. The extract from serum with hexane was saponified with potassium hydroxide and subjected to silica gel column chromatography to remove interfering substances. GGA in the partially purified extract was then reacted with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine and measured by selected ion monitoring using gas chromatography—mass spectrometry. A low detection limit (1 ng/ml) and high precision were obtained.  相似文献   

9.
Twelve compounds representing procarbazine, seven metabolites, and an internal standard were analyzed by gas chromatography—mass spectrometry on a 3% OV-1 column. Procarbazine and four metabolites were derivatized with acetic anhydride.A sensitive, specific and quantitative assay was established by selected ion monitoring using a synthetic analogue of the drug as an internal standard. The limits of detection were approximately 1 ng/ml of plasma while the limits of quantitation were 10 ng/ml of plasma.Studies on the degradation of procarbazine - HCl in 0.05 M phosphate buffer (pH 7.4) were compared to in vivo studies. At 1 h after incubation of procarbazine - HCl in buffer, the azo and aldehyde metabolites were detected in the highest concentrations representing 27.2% and 20.3% of total drug and metabolites. In the in vivo studies, analyses of rat plasmas indicated that 1 h after an oral dose of procarbazine - HCl, the aldehyde metabolite represented 72% of the total drug and metabolites, and that relatively little of the azo metabolite was present.  相似文献   

10.
11.
The dioxopiperazine metabolites of quinapril in plasma and urine were extracted with hexane—dichloroethane (1:1) under acidic conditions. Following derivatization with pentafluorobenzyl bromide and purification of the desired reaction products using a column packed with silica gel, the metabolites were analysed separately by capillary column gas chromatography—electron-impact mass spectrometry with selected-ion monitoring. The limits of quantitation for the metabolites were 0.2 ng/ml in plasma and 1 ng/ml in urine. The limits of detection were 0.1 ng/ml in plasma and 0.5 ng/ml in urine, at a signal-to-noise ratio of > 3 and > 5, respectively. The proposed method is applicable to pharmacokinetic studies.  相似文献   

12.
13.
A selective gas–liquid chromatographic method with mass spectrometry (GC–MS) for the simultaneous confirmation and quantification of ephedrine, pseudo-ephedrine, nor-ephedrine, nor-pseudoephedrine, which are pairs of diastereoisomeric sympathomimetic amines, and methyl-ephedrine was developed for doping control analysis in urine samples. O-Trimethylsilylated and N-mono-trifluoroacetylated derivatives of ephedrines — one derivative was formed for each ephedrine — were prepared and analyzed by GC–MS, after alkaline extraction of urine and evaporation of the organic phase, using d3-ephedrine as internal standard. Calibration curves, with r2>0.98, ranged from 3.0 to 50 μg/ml depending on the analyte. Validation data (specificity, % RSD, accuracy, and recovery) are also presented.  相似文献   

14.
A gas chromatography mass spectrometric method using negative chemical ionisation was developed for the determination of stable isotopes of selenium for evaluation of selenium absorption and retention from foods in humans. The method involves an acid digestion to convert all selenium into selenite, which subsequently reacts with 4-nitro-o-phenylene-diamine to form a volatile piazselenole. The piazselenole, after extraction into an organic solvent, was analysed for its isotopic selenium composition by gas chromatography mass spectrometry. Negative chemical ionisation is reported for the first time for the determination of selenium stable isotopes and its analytical characteristics were compared to those of electron impact mass spectrometric ionisation, classically used for the determination of selenium. The negative chemical ionisation technique allowed accurate determination of total selenium by isotope dilution and of selenium isotope ratios in biological samples. The repeatability for total selenium and for stable isotope ratios was good (R.S.D.≤10%) within the range of 50 to 250 ng selenium. The detection limit for the investigated selenium isotopes was approximately 1 pg (signal to noise ratio at 3). The applicability of the developed stable isotope methodology was demonstrated by the determination of the selenium absorption and retention from foods in a pilot study using one human adult.  相似文献   

15.
A gas chromatographic—mass spectrometric assay, using selected-ion monitoring (GC-MS-SIM) with thymol as internal standard, was developed for quantitating propofol, an intravenous anaesthetic. The method described is rapid and sensitive for the determination of propofol in whole blood. The sensitivity of the present method is 10 ng/ml. The recovery of propofol added to human whole blood in the concentration range 10-10 000 ng/ml ranged between 95 and 100%. A single extraction procedure was used with chloroform-ethyl acetate. The assay allowed the detection of two metabolites formed during propofol metabolism: 2,6-diisopropyl-1,4-quinone and 2,6-diisopropyl-1,4-quinol.  相似文献   

16.
A rapid and reliable gas chromatographic—mass spectrometric method for the determination of clenbuterol in urine is described. Penbutolol was used as internal standard. Four derivatization procedures have been tested, of which 1-butaneboronic acid gave the best results. The method includes extraction of the alkalinized urine (3 ml) with tert.-butyl methyl ether—n-butanol (9:1), derivatization with 1-butaneboronic acid (15 min at room temperature), and analysis in the selected-ion monitoring mode of the derivatives of clenbuterol at m/z 243, 327 and 342 and of penbutolol at m/z 342 and 357. The detection limit is 0.5 ng/ml and the recovery better than 90%.  相似文献   

17.
18.
The urine concentrations of free salsolinol were determined in six healthy volunteers, using a gas chromatographic—mass spectrometric method with electron-capture negative-ion chemical ionization after derivatization with pentafluoropropionyl anhydride. The sensitivity of this method allows the quantification of salsolinol concentrations of 0.55 pmol/ml. The synthesis of [2H4]salsolinol from dopamine and [2H4]acetaldehyde via a Pictet—Spengler condensation is described; [2H4]salsolinol was used as the internal standard for salsolinol quantification. The urine concentrations of free salsolinol ranged from ca. 1 to 6 pmol/ml.  相似文献   

19.
We devised a sensitive and simple method for determining nitrate in whole blood, using an extractive alkylation technique. Nitrate in whole blood was reduced to nitrite by hydrazine sulfate in the presence of Cu2+ and Zn2+ as catalysts, and alkylated with pentafluorobenzyl bromide using tetradecyldimethylbenzylammonium chloride as the phase-transfer catalyst. The obtained derivative was analyzed qualitatively by gas chromatography–mass spectrometry and quantitatively by gas chromatography with electron-capture detection. The detection limit of nitrate in whole blood was 0.01 mM. The calibration curve was linear over the concentration range from 0.02 to 1.0 mM for nitrate in whole blood. The accuracy and precision of the method were evaluated and the relative standard deviations were found to be within 10%. Using this method, the blood nitrate levels of two victims who committed suicide by inhaling automobile exhaust gas were determined.  相似文献   

20.
Propofol (2,6-diisopropylphenol, I.C.I. 35 868) is a rapid-acting, intravenous anesthetic agent recently introduced for the induction and maintenance of general anesthesia. This paper describes a gas chromatographic—mass spectrometric procedure using selected-ion monitoring for the determination of plasma propofol levels. The drug and the internal standard (thymol) were extracted from plasma into diethyl ether—pentane, and derivatized to their trimethylsilyl derivatives before analysis. The reproducibility of the daily standard curves had coefficients of variation ranging from 2.7% to 10.2%. The precision of the assay yielded a coefficient of variation ranging from 4.5% to 5.6%, and the concentration means for the seeded control samples were found to be within −1.6% to +0.6% of the theoretical values for propofol. No interfering peaks have been observed in application of this procedure to either normal volunteer or patient samples. The minimum detectable level under the conditions described was 0.20 ng propofol/ml plasma. This assay and a high-performance liquid chromatographic assay with fluorescence detection were both used to measure plasma propofol concentrations in 89 human plasma samples, and the correlation between the two methods was excellent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号