首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 152 毫秒
1.
A high-performance liquid chromatographic (HPLC) method based on solid-phase extraction (SPE) was developed for determination of amoxicillin, penicillin G (benzylpenicillin), ampicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in muscle, liver and kidney tissues of pigs and cattle. The compounds were extracted in aqueous solution by precipitation of organic materials with a mixture of sulphuric acid and sodium tungstate. The extract was cleaned up by SPE on a divinylbenzene-co-N-vinylpyrrolidone polymeric sorbent. Further clean-up was performed by liquid–liquid partition with diethyl ether. The extract was derivatised with benzoic anhydride and 1,2,4-triazole mercury (II) reagent. Chromatography was performed by reversed-phase gradient HPLC on a C18 column with ultraviolet detection at 323 nm. The limits of detection estimated by a conservative model were in the range 8.9–11.1 μg/kg for amoxicillin, penicillin G, ampicillin, oxacillin, cloxacillin and nafcillin and 18.3–20.9 μg/kg for dicloxacillin. The mean recovery range was 66–77% for amoxicillin, 73–75% for penicillin G, 81–82% for ampicillin, 73–76% for oxacillin, 74–75% for cloxacillin, 66–72% for nafcillin and 58–65% for dicloxacillin.  相似文献   

2.
Direct-injection LC-LC hybrid tandem MS methods have been developed for undertaking broad-based screening for acidic drugs in protein-precipitated plasma and neutral doping agents in equine urine. In both analyses, analytes present in the matrix were trapped using a HLB extraction column before being refocused and separated on a Chromolith RP-18e monolithic analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Each method has been optimised by the adoption of a mobile phase and gradient that was tailored to enhance ionisation in the MS source while maintaining good chromatographic behaviour for the majority of the target drugs. The analytical column eluent was fed into the heated nebulizer (HN) part of the Duospray interface attached to a 4000 QTRAP mass spectrometer. Information dependent acquisition (IDA) with dynamic background subtraction (DBS) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. Ninety-one percent of acidic drugs in protein-precipitated plasma and 80% of the neutral compounds in equine urine were detected when spiked at 10 ng/ml.  相似文献   

3.
Flucloxacillin, a new isoxazole penicillin, is active against penicillinase-producing strains of Staphylococcus aureus and is well absorbed in man after oral and intramuscular administration. Compared with isoxazole penicillins in current clinical use—namely, oxacillin, cloxacillin, and dicloxacillin—flucloxacillin has proved as active against Gram-positive cocci, including penicillin-resistant staphylococci. The extent of binding of flucloxacillin to the protein of human serum was similar to that of oxacillin and cloxacillin and less than that of dicloxacillin. In man flucloxacillin given orally produced total and free serum levels higher than those obtained with oxacillin and cloxacillin; total serum levels similar to those of dicloxacillin, and free levels greater than those of dicloxacillin. Similarly, after intramuscular injection the free serum levels of flucloxacillin were higher than those of oxacillin, cloxacillin, and dicloxacillin.  相似文献   

4.
The use of a monolithic column (Chromolith, SpeedROD RP-18e, by Merck) was studied on the determination of cephalosporin antibiotics. Results were compared with those from a previously developed analytical method using conventional silica-based analytical column. A rapid, accurate and sensitive method has been developed and validated for the quantitative simultaneous determination of four cephalosporins: Cephalexine and Cephadroxil (first generation), Cefaclor (second generation) and Cefotaxim (third generation) in pharmaceuticals as well as in human blood serum and urine. Hydroflumethiazide (HFM) (3,4-dihydro-6(trifluoromethyl)-2H-1,2,4-benzothiadiazine-7-sulfonamide-1,1-dioxide) was used as an internal standard at a concentration of 1.5 ng/microL. A rectilinear relationship was observed up to 5 ng/microL for the four compounds. Analysis time was less than 4 min. The statistical evaluation of the method was examined by means of within-day repeatability (n=8) and day-to-day precision (n=8) and was found to be satisfactory with high accuracy and precision results. The method was applied to the determination of the cephalosporins in commercial pharmaceuticals and in biological fluids: human blood serum after solid phase extraction and urine simply after filtration and dilution. Recovery of analytes in spiked serum samples was in the range from 88.7 to 107.8%, while for urine samples recovery was from 98.0 to 105.6%. By comparing the figures of merit for the monolithic column and the silica-based one, regarding the determination of the four cephalosporins investigated in the present study, the outstanding efficiency of the monolithic column can be noticed.  相似文献   

5.
A liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed to quantify colistin in human plasma and urine, and perfusate and urine from the isolated perfused rat kidney (IPK). Solid phase extraction (SPE) preceded chromatography on a Synergi Fusion-RP column with a mobile phase of acetonitrile, water and acetic acid (80/19/1) at 0.2mL/min. Ions were generated using electrospray ionization and detected in the positive-ion mode. Multiple reaction monitoring was performed using precursor-product ion combinations. Calibration curves were linear from 0.028microg/mL (human plasma, IPK perfusate and urine)/0.056microg/mL (human urine) to 1.78microg/mL (all four media) for colistin A sulfate; corresponding values for colistin B sulfate were 0.016/0.032 to 1.01microg/mL. Accuracy and precision were within 10%. The LLOQ for colistin A sulfate was 0.028microg/mL in human plasma, IPK perfusate and urine and 0.056microg/mL in human urine; corresponding values for colistin B sulfate were 0.016 and 0.032microg/mL. The low sample volume, short analysis time and low LLOQ are ideal for pre-clinical and human pharmacokinetic studies of colistin.  相似文献   

6.
A poly (methacrylic acid-ethylene glycol dimethacrylate, MAA-EGDMA) monolithic capillary was used for the in-tube solid-phase microextraction (in-tube SPME) of several angiotensin II receptor antagonists (ARA-IIs) from human plasma and urine. Under the optimized extraction condition, the protein component of the biological sample was flushed through the monolithic capillary, while the analytes were successfully trapped. Coupled to HPLC with fluorescence detection, this on-line in-tube SPME method was successfully applied for the determination of candesartan, losartan, irbesartan, valsartan, telmisartan, and their detection limits were found to be 0.1-15.3ng/mL and 0.1-15.2ng/mL in human plasma and urine, respectively. The method was linear over the range of 0.5-200ng/mL for telmisartan, 5-2000ng/mL for candesartan and irbesartan, 10-2000ng/mL for valsartan, and 50-5000ng/mL for losartan with correlation coefficients being above 0.9985 in plasma sample and above 0.9994 in urine sample. The method reproducibility was evaluated at three concentration levels, resulting in the R.S.D. <7%. The poly (MAA-EGDMA) monolithic capillary was demonstrated to be robust and biocompatible by using direct injections of biological samples.  相似文献   

7.
A method based on poly (methacrylic acid-co-ethylene glycol dimethacrylate) (MAA-EGDMA) monolith microextraction (PMME) and field-enhanced sample injection (FESI) pre-concentration technique was proposed for sensitive capillary electrophoresis-ultraviolet (CE-UV) analysis of ephedrine (E) and pseudoephedrine (PE) in human plasma and urine. The PMME device consisted of a regular plastic syringe (1 mL), a poly (MAA-EGDMA) monolithic capillary (2 cm x 530 microm I.D.) and a plastic pinhead connecting the former two components seamlessly. The extraction was achieved by driving the sample solution through the monolithic capillary tube using a syringe pump, for the desorption step, an aliquot of organic solvent, which normally provided an excellent medium to ensure direct compatibility for FESI in CE, was injected via the monolithic capillary and collected into a vial for subsequent analysis by CZE. The best separation was achieved using a buffer composed of 0.1M phosphate electrolyte (pH 2.5) and 10% acetonitrile (v/v). The combination of both pre-concentration procedures allowed the detection limits of the analytes down to 5.3 ng/mL and 8.0 ng/mL in human plasma and urine, respectively. Excellent method of reproducibility was found over a linear range 50-5000 ng/mL in plasma and urine sample. Plasma and urine samples from volunteers receiving pseudoephedrine have also been successfully analysed.  相似文献   

8.
A rapid and sensitive assay for the determination of dihydroergocryptine (DHEC) in human plasma and urine samples with dihydroergotamine (DHET) as the internal standard was developed. The procedure employs on-line sample preparation using an extraction pre-column and an octadecylsilylsilica (ODS) analytical column. After centrifugation human plasma or urine were injected onto the pre-column, concentrated and extracted, back-flushed onto the analytical column and eluted with a binary methanol--aqueous formic acid gradient. Either determination of DHEC as well of its mono- and dihydroxy-metabolites was performed by measurement of the signal responses from MS detection in the selected reaction monitoring (SRM) mode using the transition of the respective parent ions to the common daughter ion at m/z=270.2 amu. The limit of quantitation (LOQ) for determinations of DHEC in both plasma and urine were 25 pg/ml for injected sample volumes of 400 microl. Proportionality of signal responses versus concentration was accomplished within the range of 25-1000 pg/ml. Recovery of target analyte from plasma was 99%. Mean values of the coefficients of variation (CV) for the target analyte in plasma ranged from 1.7 to 13.8% (within-day) and 5.0 to 9.1% (between-day) and accuracy from 91.7 to 102.6% for the within-day and from 95.8 to 98.8% for the between-day measurements. The corresponding values for determinations in urine were 1.7-14.5% (within-day) and 5.3-11.8% (between-day) for CV and 95.8-110.7% (within-day) and 100.1-104.6% (between-day) for accuracy.  相似文献   

9.
A quantitative liquid chromatography positive ion electrospray tandem mass spectrometric method for the simultaneous determination of sulforaphane, iberin and their metabolites in human urine and plasma is described. The stability of the metabolites was determined in aqueous solution and in human plasma. Gradient liquid chromatographic separation was performed on a Zorbax SB-Aq 3.5 microm (100 x 2.1mm) column, using a mobile phase (flow rate 0.25 mL/min) consisting of ammonium acetate buffer at pH 4 and acetonitrile. Butyl thiocarbamoyl l-cysteine was used as internal standard. The assay was linear (r(2)>0.99) over the range of 0.03-300 microM in urine and 0.03-15 microM in plasma with intra- and inter-day assay precision (<10% CV) and accuracy (<20%). The lower limits of quantitation were in the range of 10-150 nmol/L. The method has been used to report, for the first time, individual quantitative measurement of each of the mercapturic acid pathway metabolites of sulforaphane and iberin in both human plasma and urine following a dietary study of broccoli consumption.  相似文献   

10.
A sensitive method was developed to determine fexofenadine in human plasma and urine by HPLC-electrospray mass spectrometry with MDL 026042 as internal standard. Extraction was carried out on C18 solid-phase extraction cartridges. The mobile phases used for HPLC were: (A) 12 mM ammonium acetate in water and (B) acetonitrile. Chromatographic separation was achieved on a LUNA CN column (10 cm x 2.0 mm I.D., particle size 3 microm) using a linear gradient from 40% B to 60% B in 10 min. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH+ ions, m/z 502.3 for fexofenadine and m/z 530.3 for the internal standard. The limit of quantification achieved with this method was 0.5 ng/ml in plasma and 1.0 ng in 50 microl of urine. The method described was successfully applied to the determination of fexofenadine in human plasma and urine in pharmacokinetic studies.  相似文献   

11.
BackgroundMonolithic chromatography using convective interaction media (CIM) disks or columns can be used in the separation step of speciation analysis. When different monolithic disks are placed in one housing, forming conjoint liquid chromatography (CLC) monolithic column, two-dimensional separation is achieved in a single chromatographic run.MethodsHere, we assembled low-pressure (maximum 50 bar) CLC monolithic column, which consists of two 0.34 mL shallow CIM monolithic disks and high-pressure CLC column (maximum 150 bar) from 0.1 mL analytical high performance short bed CIMac monolithic disks. Both the CLC columns constructed from affinity Protein G and weak anion exchange diethylamine (DEAE) disks, were applied for the speciation of cisplatin, oxaliplatin and carboplatin in spiked standard serum proteins, spiked human serum and serum of cancer patients. The analytical performances of the CLC columns used were evaluated by comparing their robustness, selectivity, repeatability and reproducibility. The separated serum proteins were detected on-line by ultraviolet (UV) and eluted Pt species by inductively coupled plasma mass spectrometry (ICP-MS). For accurate quantification of the separated Pt species (unbound Pt-based chemotherapeutic from species associated to transferrin (Tf), human serum albumin (HSA) and Immunoglobulin G (IgG)), post column isotope dilution (ID)-ICP-MS was used.ResultsThe data from analyses showed that both tested CLC monolithic columns gave statistically comparable results, with the low-pressure CLC column exhibiting better resolving power and robustness. It also enables more effective cleaning of monolithic disks and to analyse larger series of serum samples than the high-pressure CLC column. Analyses of serum samples of cancer patients treated with cisplatin or carboplatin showed that Pt-chemotherapeutics were bound preferentially to HSA (around 80%). The portion of unbound Pt in general did not exceed 2%, up to 5% of Pt was associated with Tf and approximately 20% with IgG. Column recoveries, calculated as a ratio between the sum of concentrations of Pt species eluted and concentration of total Pt in serum samples, were close to 100%.ConclusionsLow-pressure CLC column exhibited greater potential than high-pressure CLC column, and can be thus recommended for its intended use in speciation analysis of metal-based biomolecules.  相似文献   

12.
Gadocoletate ion is a new paramagnetic intravascular contrast agent for magnetic resonance imaging (MRI). An high-performance liquid chromatographic method for assaying Gadocoletate ion in human plasma, urine and faecal samples is described. The analysis is based on the reversed-phase chromatographic separation of Gadocoletate ion from the endogenous components of the biological matrices and its detection during elution by ultraviolet light absorption at 200 nm. The selectivity of the method was satisfactory. The mean absolute recovery during the analytical sample preparation was greater than 87%. The precision, expressed as coefficient of variation (CV%) ranged from 0.29 to 5.90% and the accuracy, expressed as mean relative error (R.E.%) of the analytical method ranged from -3.7 to +7.1%. The detection limit in plasma and urine was 2.01 and 10.0 microg/mL (0.00203 and 0.0101 micromol/mL), respectively. The detection limit in homogenized faecal samples was 17.7 microg/g (0.0179 micromol/g). Stability studies were performed in human plasma and urine samples during the analytical cycle. Gadocoletate ion was shown to be stable in human plasma and in human urine when stored at about +4 degrees C for up 24 h, and after three freeze-thaw cycles. In addition, it was shown to be stable in samples of processed plasma and in diluted urine at about +4 degrees C for 48 h, and at room temperature for at least 24 h. As regards the long-term stability of Gadocoletate ion, the results of dedicated studies showed that Gadocoletate ion is stable in human plasma samples when stored at +4 degrees C for up to 30 days and at -80 degrees C for up to 90 days. Gadocoletate ion is stable in samples of human urine when stored at +4 degrees C for up to 30 days, and when stored at -20 degrees C and at -80 degrees C for up to 90 days. The method has been successfully validated in human plasma, urine and faeces and it has been shown to be precise, accurate and reliable.  相似文献   

13.
Interaction of oxacillin, cloxacillin, dicloxacillin, phenoxymethylpenicillin, methicillin, nafcillin and benzylpenicillin with human serum albumin (HSA) was studied with flow microcalorimetry and differential scanning calorimetry. The measured thermodynamic parameters of complex formation between the penicillins and HSA were compared with similar characteristics of their binding to bovine serum albumin. It was shown that there were species differences between these two globular proteins in their interaction with the above antibiotics in relation to both the number of the biopolymer active sites and the nature of the molecular forces in the complex formation. The effect of the first bound molecule of oxacillin, cloxacillin, dicloxacillin, nafcillin, phenoxymethylpenicillin and benzylpenicillin on HSA conformation was observed. It was demonstrated that there was thermostabilization of HSA on its interaction with the above drugs with preserving cooperative nature of thermal denaturation of the complexes in relation to HSA melting.  相似文献   

14.
The two antiproteases alpha 1-antitrypsin (alpha 1-AT) and antithrombin-III (AT-III) have been purified simultaneously from human plasma. Purification procedure consisted of gel filtration on Sephadex G-200 after initial processing of plasma, followed by ion exchange chromatography on DEAE-Sephadex A50 and DEAE-Cellulose, at a pH of 9.0 and pH 8.3 respectively. The two proteins could not be separated by any of these procedures including a lower pH (7.4) in ion exchange chromatography. Affinity chromatography on heparin-Sepharose separated the proteins since alpha 1-AT did not bind to the matrix. Alpha 1-AT unbound to the heparin-Sepharose was subsequently purified through con A-Sepharose affinity column. The final yield of both the proteins was about 20%. The molecular weight estimated on SDS electrophoresis for AT-III and alpha 1-AT was 63,000 and 50,000, respectively.  相似文献   

15.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) are chromatographed on a column packed with Spherosil XOA 600 (5 μm) using a 7:3 (v/v) mixture of diisopropyl ether—isooctane (1:1, v/v) + 0.2% triethylamine and diisopropyl ether—methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. < 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

16.
Methods employing monolithic HPLC columns for the determination of the cyclooxygenase II inhibitors rofecoxib (I) and 3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one (DFP, III) in human plasma are described. Each analyte, together with an internal standard was extracted from the plasma matrix using solid-phase extraction in the 96-well format. The analytes were chromatographed on a Chromolith Speed Rod monolithic HPLC column (4.6 x 50 mm). Analyte detection for rofecoxib was via fluorescence following post-column photochemical derivatization. Detection for III was based on the native fluorescence of the compound. The precision, accuracy, and linearity of the methods were found to be comparable to those obtained using methods employing conventional packed HPLC columns. Use of the monolithic column permitted mobile phase flow-rates of up to 6.5 ml/min to be employed in the assays. The use of elevated flow-rates enabled the per sample analysis time to be reduced by up to a factor of 5 compared with assays based on packed HPLC columns. The results of experiments aimed at evaluating the ruggedness and reproducibility of monolithic columns employed in bioanalytical methods are presented.  相似文献   

17.
Sugammadex (Bridion?, Merck Sharp & Dohme Corp., Oss, The Netherlands) is a modified γ-cyclodextrin which has the ability to reverse the neuromuscular blockade induced by the steroidal neuromuscular blocking agents rocuronium and vecuronium. The objective of the current study is to describe the bioanalytical methods that have been developed and validated according to US Food and Drug Administration guidelines on bioanalytical method validation, and subsequently applied to determine total sugammadex (i.e., free sugammadex plus sugammadex bound to the neuromuscular blocking agent) in human heparinized plasma, urine and dialysate. Sugammadex was extracted from human plasma and urine using solid phase extraction with Isolute HAX 96-well extraction plates; no extraction was performed on dialysate samples. Samples from plasma, urine, and dialysate were analyzed on a Polaris? C18-A PEEK (polyaryletheretherketone) analytical column (50 mm × 4.6 mm internal diameter, 5 μm) with a linear mobile phase gradient of 0.1% (v/v) formic acid in water:methanol from 70:30 to 20:80. The flow rate was 1 mL/min with a total run time for each injection of 6 min. Tandem mass spectrometric detection was conducted using multiple reaction monitoring under negative ion mode with a turbo ion-spray interface to quantify the concentration of sugammadex. Inter- and intra-assay precision and accuracy were within pre-defined acceptance limits. The presence of rocuronium did not interfere with the assay in plasma, urine or dialysate; similarly, vecuronium did not interfere with the plasma assay (not tested for interference in urine or dialysate). Sugammadex was found to be stable in plasma, urine and dialysate in the short-term at room temperature, in the long-term at -20°C, and after several freeze/thaw cycles. The validated bioanalytical methods developed here have been successfully applied in a series of clinical studies for the determination of total sugammadex in plasma, urine and dialysate.  相似文献   

18.
A high-performance liquid chromatographic method based on C18 solid-phase extraction and ultraviolet detection at 323 nm of analytes derivatized with benzoic anhydride and 1,2,4-triazole mercuric chloride solution was developed for the simultaneous determination of amoxicillin, penicillin G (benzylpenicillin), ampicillin, oxacillin, cloxacillin and dicloxacillin residues in raw milk. The detection limit of the method was 1.3 μg/l for penicillin G; 1.4 μg/l for amoxicillin, oxacillin and cloxacillin, 1.5 μg/l for ampicillin and 2.7 μg/l for dicloxacillin. The mean recovery was 95–102% for amoxicillin, penicillin G and ampicillin, 92–98% for oxacillin and cloxacillin and 87–94% for dicloxacillin, measured by using an internal standard. The relative repeatability standard deviation was 4–9% on level 4–15 μg/l, respectively, 2–7% on level 30–40 μg/l.  相似文献   

19.
A novel ion-pair reversed phase electrospray ionization (IP-RP-ESI) liquid chromatography-mass spectrometry (LC-MS) method has been developed for identification and quantification of Bcl-2 antisense phosphorothioate oligonucleotides G3139 and metabolites in plasma. This method utilized solid phase extraction for desalting and matrix removal and detection by an ion trap mass spectrometer. Resolution was accomplished on a micro C18 column eluted with a mobile phase consisting of hexafluoro-2-propanol and triethylamine in methanol at 50 degrees C. Five G3139 metabolites were identified in plasma and urine from treated patients and rats. A cassette HPLC-MS/MS quantification method for G3139 and three metabolites was developed and validated with a limit of quantification (LOQ) of 17.6 nM in human and rat plasma with acceptable precision and accuracy. Plasma pharmacokinetics of G3139 and metabolites in these species were described.  相似文献   

20.
A sensitive and selective high-performance liquid chromatographic (HPLC) method was developed for the determination of pramipexole in human plasma and urine. Plasma/urine is made alkaline before pramipexole and BHT-920 (internal standard) are extracted by ethyl ether and back-extracted with a solution that contains heptanesulfonic acid. Separation is achieved by ion-pair chromatography on a Zorbax Rx C8 column with electrochemical detection at 0.6 V for plasma and ultraviolet detection at 286 nm for urine. The retention times of pramipexole and internal standard are approximately 14.4 and 10.7 min, respectively. The assay is linear in concentration ranges of 50 to 15 000 pg/ml (plasma) and 10 to 10 000 ng/ml (urine). The correlation coefficients are greater than 0.9992 for all curves. For the plasma method, the analysis of pooled quality controls (300, 3000, and 10 000 pg/ml) demonstrates excellent precision with relative standard deviations (R.S.D.) (n=18) of 1.1%, 2.3%, and 6.8%, respectively. For the urine method, quality control pools prepared at 30, 300, and 3000 ng/ml had R.S.D. values (n=18) of 2.9%, 1.7%, and 3.0%, respectively. The plasma and urine controls were stable for more than nine and three months, respectively. The mean recoveries for pramipexole and internal standard from plasma were 97.7% and 98.2%, respectively. The mean recoveries for pramipexole and internal standard from urine were 89.8% and 95.1%, respectively. The method is accurate with all intra-day (n=6) and overall (n=18) mean values for the quality control samples being less than 6.4 and 5.8% from theoretical for plasma and urine, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号