首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We explore the potential of a supercritical angle (SA) objective for fluorescence correlation spectroscopy (FCS). This novel microscope objective combines tight focusing by an aspheric lens with strong axial confinement of supercritical angle fluorescence collection by a parabolic mirror lens, resulting in a small detection volume. The tiny axial extent of the detection volume features an excellent surface sensitivity, as is demonstrated by diffusion measurements in model membranes with an excess of free dye in solution. All SA-FCS measurements are directly compared to standard confocal FCS, demonstrating a clear advantage of SA-FCS, especially for diffusion measurements in membranes. We present an extensive theoretical framework that allows for accurate and quantitative evaluation of the SA-FCS correlation curves.  相似文献   

2.
Two methods to combine fluorescence correlation spectroscopy (FCS) with modulated excitation, in a way that allows extraction of correlation data for all correlation times have been developed and experimentally verified. One method extracts distortion-free correlation data from measurements acquired with standard hardware correlators provided the fluorescence does not change systematically within the excitation pulses. This restriction does not apply to the second method, which, however, requires time-resolved acquisition of the fluorescence intensity. Modulation of the excitation in an FCS experiment is demonstrated to suppress triplet population buildup more efficiently than a corresponding reduction in continuous wave excitation intensity (shown for the dye rhodamine 6G in aqueous solution). Excitation modulation thus offers an additional means to optimize the FCS measurement conditions with respect to the photophysical properties of the dyes used. This possibility to suppress photoinduced states also provides a useful tool to distinguish additional processes occurring in the same time regime in the FCS measurements, as demonstrated here for the protonation kinetics of fluorescein at different pH. In general, the proposed concept opens for FCS measurements with a complete correlation timescale in a range of applications where a modulated excitation is either necessary or brings specific advantages.  相似文献   

3.
Fluorescence correlation spectroscopy (FCS) is an ideal analytical tool for studying concentrations, propagation, interactions and internal dynamics of molecules at nanomolar concentrations in living cells. FCS analyzes minute fluorescence-intensity fluctuations about the equilibrium of a small ensemble (<10(3)) of molecules. These fluctuations act like a 'fingerprint' of a molecular species detected when entering and leaving a femtoliter-sized optically defined observation volume created by a focused laser beam. In FCS the fluorescence fluctuations are recorded as a function of time and then statistically analyzed by autocorrelation analysis. The resulting autocorrelation curve yields a measure of self-similarity of the system after a certain time delay, and its amplitude describes the normalized variance of the fluorescence fluctuations. By fitting the curves to an appropriate physical model, this method provides precise information about a multitude of measurement parameters, including diffusion coefficients, local concentration, states of aggregation and molecular interactions. FCS operates in real time with diffraction-limited spatial and sub-microsecond temporal resolution. Assessing diverse molecular dynamics within the living cell is a challenge well met by FCS because of its single-molecule sensitivity and high dynamic resolution. For these same reasons, however, intracellular FCS measurements also harbor the large risk of collecting artifacts and thus producing erroneous data. Here we provide a step-by-step guide to the application of FCS to cellular systems, including methods for minimizing artifacts, optimizing measurement conditions and obtaining parameter values in the face of diverse and complex conditions of the living cell. A discussion of advantages and disadvantages of one-photon versus two-photon excitation for FCS is available in Supplementary Methods online.  相似文献   

4.
Continuous fluorescence microphotolysis (CFM) and fluorescence correlation spectroscopy (FCS) permit measurement of molecular mobility and association reactions in single living cells. CFM and FCS complement each other ideally and can be realized using identical equipment. So far, the spatial resolution of CFM and FCS was restricted by the resolution of the light microscope to the micrometer scale. However, cellular functions generally occur on the nanometer scale. Here, we develop the theoretical and computational framework for CFM and FCS experiments using 4Pi microscopy, which features an axial resolution of ∼100 nm. The framework, taking the actual 4Pi point spread function of the instrument into account, was validated by measurements on model systems, employing 4Pi conditions or normal confocal conditions together with either single- or two-photon excitation. In all cases experimental data could be well fitted by computed curves for expected diffusion coefficients, even when the signal/noise ratio was small due to the small number of fluorophores involved.  相似文献   

5.
Fluorescence correlation spectroscopy (FCS) is rapidly growing in popularity as a biomedical research tool. FCS measurements can produce an accurate characterization of the chemical, physical, and kinetic properties of a biological system. They can also serve as a diagnostic, detecting particular molecular species with high sensitivity and specificity. We here demonstrate that dual-color FCS measurements can be applied to detect and quantify the concentration of specific non-fluorescent molecular species without requiring any modifications to the molecule of interest. We demonstrate this capability by applying dual-color two-photon fluorescence cross-correlation spectroscopy to detect single stranded gamma tubulin DNA in solution with high sensitivity. This quantification is independent of molecular size, and the methods introduced can be extended to measurements in complex environments such as within living cells.  相似文献   

6.
We used fluorescence correlation spectroscopy (FCS) to analyze the binding of fluorescently labeled peptides to lipid vesicles and compared the deduced binding constants to those obtained using other techniques. We used a well-characterized peptide corresponding to the basic effector domain of myristoylated alanine-rich C kinase substrate, MARCKS(151-175), that was fluorescently labeled with Alexa488, and measured its binding to large unilamellar vesicles (diameter approximately 100 nm) composed of phosphatidylcholine and phosphatidylserine or phosphatidylinositol 4,5-bisphosphate. Because the large unilamellar vesicles are significantly larger than the peptide, the correlation times for the free and bound peptide could be distinguished using single color autocorrelation measurements. The molar partition coefficients calculated from the FCS measurements were comparable to those obtained from binding measurements of radioactively labeled MARCKS(151-175) using a centrifugation technique. Moreover, FCS can measure binding of peptides present at very low concentrations (1-10 nmolar), which is difficult or impossible with most other techniques. Our data indicate FCS can be an accurate and valuable tool for studying the interaction of peptides and proteins with lipid membranes.  相似文献   

7.
R D Icenogle  E L Elson 《Biopolymers》1983,22(8):1919-1948
Fluorescence correlation spectroscopy (FCS) and fluorescence photobleaching recovery (FPR) are two methods that may be used to measure diffusion and chemical reaction kinetics in small, labile systems such as biological cells. These methods are here applied to systems in which a fluorescent ligand can bind to a polyvalent substrate molecule in a multistep reaction sequence. The analytical theory for both FCS and FPR is extended to allow analysis of these kinds of systems. Experimental measurements of the binding of ethidium bromide to DNA by FCS confirm the theoretical analysis. (FPR measurements on the same system are reported in the accompanying paper.) The analysis shows that FCS and FPR perceive multivalent binding reactions differently. This difference results from the selective effect of the photobleaching process in the chemical reaction system. The development and results we report could have useful applications to a wide range of biopolymeric binding and assembly process.  相似文献   

8.
Fluorescence correlation spectroscopy (FCS) methods are powerful tools for unveiling the dynamical organization of cells. For simple cases, such as molecules passively moving in a homogeneous media, FCS analysis yields analytical functions that can be fitted to the experimental data to recover the phenomenological rate parameters. Unfortunately, many dynamical processes in cells do not follow these simple models, and in many instances it is not possible to obtain an analytical function through a theoretical analysis of a more complex model. In such cases, experimental analysis can be combined with Monte Carlo simulations to aid in interpretation of the data. In response to this need, we developed a method called FERNET (Fluorescence Emission Recipes and Numerical routines Toolkit) based on Monte Carlo simulations and the MCell-Blender platform, which was designed to treat the reaction-diffusion problem under realistic scenarios. This method enables us to set complex geometries of the simulation space, distribute molecules among different compartments, and define interspecies reactions with selected kinetic constants, diffusion coefficients, and species brightness. We apply this method to simulate single- and multiple-point FCS, photon-counting histogram analysis, raster image correlation spectroscopy, and two-color fluorescence cross-correlation spectroscopy. We believe that this new program could be very useful for predicting and understanding the output of fluorescence microscopy experiments.  相似文献   

9.
Fluorescence correlation spectroscopy (FCS) enables direct observation of the translational diffusion of single fluorescent molecules in solution. When fluorescent hapten binds to antibody, analysis of FCS data yields the fractional amounts of free and bound hapten, allowing determination of the equilibrium binding constant. Equilibrium dissociation constants of anti-digoxin antibodies and corresponding fluorescein-labeled digoxigenin obtained by FCS and fluorescence polarization measurements are identical. It is also possible to follow a competitive displacement of the tracer from the antibody by unlabeled hapten using FCS in an immunoassay format. The fluorescence polarization immunoassay for vancomycin detection was used to test the FCS approach. Fitting of the FCS data for the molar fractions of free and bound fluorescein-labeled vancomycin yielded a calibration curve which could serve for determination of the vancomycin concentration in biological samples.  相似文献   

10.
Current methods for analysis of data from studies of protein-protein interactions using fluorescence resonance energy transfer (FRET) emerged from several decades of research using wide-field microscopes and spectrofluorometers to measure fluorescence from individual cells or cell populations. Inherent to most measurements is an averaging of the distributions of FRET efficiencies over large populations of protein complexes, which washes out information regarding the stoichiometry and structure of protein complexes. Although the introduction of laser-scanning microscopes in principle could facilitate quantification of the distributions of FRET efficiencies in live cells, only comparatively recently did this potential fully materialize, through development of spectral- or lifetime-based approaches. To exploit this new opportunity in molecular imaging, it is necessary to further develop theoretical models and methods of data analysis. Using Monte Carlo simulations, we investigated FRET in homogenous and inhomogeneous spatial distributions of molecules. Our results indicate that an analysis based on distributions of FRET efficiencies presents significant advantages over the average-based approach, which include allowing for proper identification of biologically relevant FRET. This study provides insights into the effect of molecular crowding on FRET, and it offers a basis for information extraction from distributions of FRET efficiencies using simulations-based data fitting.  相似文献   

11.
Ultrasensitive detection methods such as laser-induced fluorescence represent the current state-of-the-art in analytics. Single-molecule detection in solution has received a remarkable amount of attention in the last few years because of its applicability to life sciences. Studies have been performed on the fundamentals of the detection processes themselves and on some biological systems. Fluorescence correlation spectroscopy (FCS) is the link for ultrasensitive multicomponent analysis, showing possibilities for experiments on molecular interactions. Based on the theoretical background of FCS, this article gives full explanation of FCS and an update of highlights in experimental biology and medicine studied by FCS. We focus on a repertoire of diverse immunoglobulin specificities, a ribosome display system, single-molecule DNA sequencing, and a mutant enzyme generated by random mutagenesis of amino acids. We describe the usefulness and the enormous potential of the methodology. Further, this contribution clearly indicates that FCS is a valuable tool for solution-phase single-molecule (SPSM) experiments in immunobiology and medicine. In experiments with the Goodpasture autoantibody, we worked out conditions for the design of experiments on a complex single molecule in solution. The possibility to use SPSM-FCS as a quantitation methodology opens up other important applications beyond the scope of this article. Original results extending the published studies are presented for the rational foundation of SPSM-FCS. In this original contribution, we deal with experimental systems for biology and medicine where the number of molecules in solution is very small. This article is mandatory for gaining confidence in the interpretation of experimental SPSM-FCS results on the selfsame, individual single molecule in solution.  相似文献   

12.
13.
Investigation of lipid lateral mobility in biological membranes and their artificial models provides information on membrane dynamics and structure; methods based on optical microscopy are very convenient for such investigations. We focus on fluorescence correlation spectroscopy (FCS), explain its principles and review its state of the art versions such as 2-focus, Z-scan or scanning FCS, which overcome most artefacts of standard FCS (especially those resulting from the need for an external calibration) making it a reliable and versatile method. FCS is also compared to single particle tracking and fluorescence photobleaching recovery and the applicability and the limitations of the methods are briefly reviewed. We discuss several key questions of lateral mobility investigation in planar lipid membranes, namely the influence which membrane and aqueous phase composition (ionic strength and sugar content), choice of a fluorescent tracer molecule, frictional coupling between the two membrane leaflets and between membrane and solid support (in the case of supported membranes) or presence of membrane inhomogeneities has on the lateral mobility of lipids. The recent FCS studies addressing those questions are reviewed and possible explanations of eventual discrepancies are mentioned.  相似文献   

14.
On the analysis of high order moments of fluorescence fluctuations.   总被引:6,自引:3,他引:3  
A simple, straightforward analysis to characterize the distribution of aggregate sizes in a reversible aggregation system at equilibrium is presented. The method, an extension of fluorescence correlation spectroscopy (FCS), is based on measurements of higher order moments of spontaneous fluctuations of fluorescence intensity emitted from a defined open region of the sample. These fluctuations indicate fluctuations of the numbers of the fluorescent molecules in the observation region. Shot noise resulting from the random character of fluorescence emission and from the photoelectric detection system is modeled as a Poisson distribution and is subtracted from the measured photon count fluctuation moments to yield the desired fluorescence fluctuation moments. This analysis can also be used to estimate the fraction of immobile fluorophores in FCS measurements.  相似文献   

15.
A mathematical model of the fluorescence decay experiment based on linear systems theory is presented. The model suggests an experimental technique that increases the probability of correctly determining the decay constants of a multicomponent system. The use of moment methods for data analysis improves accuracy by combining information obtained from several discrete experiments. Examples are presented to show that the analysis of a three component system composed of known standards is improved as the number of experimental determinations is increased from one to four. The discrete measurements are made by changing the excitation and emission wavelengths.  相似文献   

16.
17.
Fluorescence correlation spectroscopy (FCS) is a widely used technique in biophysics and has helped address many questions in the life sciences. It provides important advantages compared to other fluorescence and biophysical methods. Its single molecule sensitivity allows measuring proteins within biological samples at physiological concentrations without the need of overexpression. It provides quantitative data on concentrations, diffusion coefficients, molecular transport and interactions even in live organisms. And its reliance on simple fluorescence intensity and its fluctuations makes it widely applicable. In this review we focus on applications of FCS in live samples, with an emphasis on work in the last 5 years, in the hope to provide an overview of the present capabilities of FCS to address biologically relevant questions.  相似文献   

18.
Fluorescence correlation spectroscopy (FCS) is a powerful technique to study dynamic biomolecular processes. It allows the estimation of concentrations, diffusion coefficients, molecular interactions, and other processes causing fluctuations in the fluorescence intensity, thus yielding information about aggregation processes, enzymatic reactions, or partition coefficients. During the last years, FCS has been successfully applied to model and cellular membranes, proving to be a promising tool for the study of membrane dynamics and protein/lipid interactions. Here we describe the theoretical basis of FCS and some practical implications for its application in membrane studies. We discuss sources of potential artifacts, such as membrane undulations, positioning of the detection volume, and photobleaching. Special attention is paid to aspects related to instrumentation and sample preparation as well as data acquisition and analysis. Finally, we comment on some strategies recently developed for the specific improvement of FCS measurements on membranes.  相似文献   

19.
Giant unilamellar vesicles (GUVs) have been widely used as a model membrane system to study membrane organization, dynamics, and protein-membrane interactions. Most recent studies have relied on imaging methods, which require good contrast for image resolution. Multiple sequential image processing only detects slow components of membrane dynamics. We have developed a new fluorescence correlation spectroscopy (FCS) technique, termed scanning FCS (i.e., SFCS), which performs multiple FCS measurements simultaneously by rapidly directing the excitation laser beam in a uniform (circular) scan across the bilayer of the GUVs in a repetitive fashion. The scan rate is fast compared to the diffusion of the membrane proteins and even small molecules in the GUVs. Scanning FCS outputs a "carpet" of timed fluorescence intensity fluctuations at specific points along the scan. In this study, GUVs were assembled from rat kidney brush border membranes, which included the integral membrane proteins. Scanning FCS measurements on GUVs allowed for a straightforward detection of spatial-temporal interactions between the protein and the membrane based on the diffusion rate of the protein. To test for protein incorporation into the bilayers of the GUVs, antibodies against one specific membrane protein (NaPi II cotransporter) were labeled with ALEXA-488. Fluorescence images of the GUVs in the presence of the labeled antibody showed marginal fluorescence enhancement on the GUV membrane bilayers (poor image contrast and resolution). With the application of scanning FCS, the binding of the antibody to the GUVs was detected directly from the analysis of diffusion rates of the fluorescent antibody. The diffusion coefficient of the antibody bound to NaPi II in the GUVs was approximately 200-fold smaller than that in solution. Scanning FCS provided a simple, quantitative, yet highly sensitive method to study protein-membrane interactions.  相似文献   

20.
The architectural organization of chromatin can play an important role in genome regulation by affecting the mobility of molecules within its surroundings via binding interactions and molecular crowding. The diffusion of molecules at specific locations in the nucleus can be studied by fluorescence correlation spectroscopy (FCS), a well-established technique based on the analysis of fluorescence intensity fluctuations detected in a confocal observation volume. However, detecting subtle variations of mobility between different chromatin regions remains challenging with currently available FCS methods. Here, we introduce a method that samples multiple positions by slowly scanning the FCS observation volume across the nucleus. Analyzing the data in short time segments, we preserve the high temporal resolution of single-point FCS while probing different nuclear regions in the same cell. Using the intensity level of the probe (or a DNA marker) as a reference, we efficiently sort the FCS segments into different populations and obtain average correlation functions that are associated to different chromatin regions. This sorting and averaging strategy renders the method statistically robust while preserving the observation of intranuclear variations of mobility. Using this approach, we quantified diffusion of monomeric GFP in high versus low chromatin density regions. We found that GFP mobility was reduced in heterochromatin, especially within perinucleolar heterochromatin. Moreover, we found that modulation of chromatin compaction by ATP depletion, or treatment with solutions of different osmolarity, differentially affected the ratio of diffusion in both regions. Then, we used the approach to probe the mobility of estrogen receptor-α in the vicinity of an integrated multicopy prolactin gene array. Finally, we discussed the coupling of this method with stimulated emission depletion FCS for performing FCS at subdiffraction spatial scales.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号