首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Flow-mediated dilation (FMD) measures the ability of an artery to relax in response to increases in blood velocity. FMD, primarily of the brachial artery, has been used as a noninvasive method of assessing vascular health. The purpose of this study was to assess FMD in the lower legs of humans. Six healthy subjects (27 PlusMinus; 6 yrs) were tested. Doppler ultrasound images of the posterior tibial artery were taken before, during, and after 5 minutes of proximal cuff occlusion. FMD was measured as the percent increase in diameter after cuff release. Vascular tone was calculated using the resting diameter as a percentage of the vessel's vasoactive range. Minimum diameter occurred during ischemia and maximal diameter occurred following reactive hyperemia with local heating. The lower leg was heated with 10 minutes of immersion in 44 degrees C water. Mean diameters at rest, cuff, and during release were 0.267 PlusMinus; 0.062, 0.162 PlusMinus; 0.036, 0.302 PlusMinus; 0.058 cm, respectively. FMD was 13.5 PlusMinus; 6.6 % and vascular tone was 29 PlusMinus; 16.3%. We also found that retesting on a second day produced mean diameter values within 8% of the first day. Larger resting diameter (decreased tone) correlated with decreased FMD (r2 = 0.73). These results suggest that FMD and vascular tone can be measured in the posterior tibial artery. This is a potentially powerful tool to non-invasively measure vascular health in the lower legs of people at risk for vascular disease.  相似文献   

2.
Translating photoacoustic imaging (PAI) into clinical setup is a challenge. Handheld clinical real‐time PAI systems are not common. In this work, we report an integrated photoacoustic (PA) and clinical ultrasound imaging system by combining light delivery with the ultrasound probe for sentinel lymph node imaging and needle guidance in small animal. The open access clinical ultrasound platform allows seamless integration of PAI resulting in the development of handheld real‐time PAI probe. Both methylene blue and indocyanine green were used for mapping the sentinel lymph node using 675 and 690 nm wavelength illuminations, respectively. Additionally, needle guidance with combined ultrasound and PAI was demonstrated using this imaging system. Up to 1.5 cm imaging depth was observed with a 10 Hz laser at an imaging frame rate of 5 frames per second, which is sufficient for future translation into human sentinel lymph node imaging and needle guidance for fine needle aspiration biopsy.   相似文献   

3.
Following the advent of digital subtraction angiography (DSA), carbon dioxide gas has become a useful contrast agent for arterial angiography. Former manual injection methods had precluded accurate dosing and reproducibility. An original gas injector was therefore developed and tested in a circulatory system model. This permitted an accurate evaluation of vascular gas-filling. it also proved possible to measure the injection parameters taking different influencing factors into account. It was shown that vessels up to 10 mm in diameter are virtually completely filled with gas. In vessels larger than 10 mm in diameter, a residual fluid level remains, which in turn reduces the possibility for complete vessel imaging. The injection flow is dependent primarily on the vascular circulation rate, vessel diameter and the inclination of the vessel. With respect to other factors examined, neither catheter size, number of holes nor the direction of the injection have any relevant influence.  相似文献   

4.
Brachial artery ultrasound is commonly employed for noninvasive assessment of endothelial function. However, analysis is observer dependent and susceptible to errors. We describe studies on a computerized edge-detection and wall-tracking software program to allow more accurate and reproducible measurement. In study 1, three purpose-built Perspex phantom arteries, 3.00, 4.00, and 6.00 mm in diameter, were measured with the software. There was a mean bias of 11 microm (P < 0.001 at each level) between known and measured values; the mean resolving power of the software was estimated as 8.3 microm. In study 2, the mean intraobserver coefficient of variation of repeated measures of flow-mediated dilation (FMD) using the software (6.7%) was significantly lower than that for traditional manual measurements using the intima-lumen interfaces (24.8%, P < 0.05) and intima-media interfaces (32.5%, P < 0.05). In study 3, 24 healthy volunteers underwent repeat testing twice within 1 wk; the coefficients of variation for between-visit reproducibility of FMD and response to glyceryl trinitrate using the software were 14.7 and 17.6%, respectively. Assuming 80% power and an alpha of 0.05, eight subjects with matched controls would be required, in a parallel designed study, to detect an absolute 2.5% change in FMD. In summary, we have developed a semiautomated computerized vascular ultrasound analysis system that will improve the power of clinical intervention studies to detect small changes in arterial diameter.  相似文献   

5.
Flow-mediated dilation (FMD) has become a commonly applied approach for the assessment of vascular function and health, but methods used to calculate FMD differ between studies. For example, the baseline diameter used as a benchmark is sometimes assessed before cuff inflation, whereas others use the diameter during cuff inflation. Therefore, we compared the brachial artery diameter before and during cuff inflation and calculated the resulting FMD in healthy children (n=45; 10+/-1 yr), adults (n=31; 28+/-6 yr), and older subjects (n=22; 58+/-5 yr). Brachial artery FMD was examined after 5 min of distal ischemia. Diameter was determined from either 30 s before cuff inflation or from the last 30 s during cuff inflation. Edge detection and wall tracking of high resolution B-mode arterial ultrasound images was used to calculate conduit artery diameter. Brachial artery diameter during cuff inflation was significantly larger than before inflation in children (P=0.02) and adults (P<0.001) but not in older subjects (P=0.59). Accordingly, FMD values significantly differed in children (11.2+/-5.1% vs. 9.4+/-5.2%; P=0.02) and adults (7.3+/-3.2% vs. 4.6+/-3.3%; P<0.001) but not in older subjects (6.3+/-3.4% vs. 6.0+/-4.2%; P=0.77). When the diameter before cuff inflation was used, an age-dependent decline was evident in FMD, whereas FMD calculated using the diameter during inflation was associated with higher FMD values in older than younger adults. In summary, the inflation of the cuff significantly increases brachial artery diameter, which results in a lower FMD response. This effect was found to be age dependent, which emphasizes the importance of using appropriate methodology to calculate the FMD.  相似文献   

6.

Purpose

To demonstrate the feasibility of a miniature handheld optical coherence tomography (OCT) imager for real time intraoperative vascular patency evaluation in the setting of super-microsurgical vessel anastomosis.

Methods

A novel handheld imager Fourier domain Doppler optical coherence tomography based on a 1.3-µm central wavelength swept source for extravascular imaging was developed. The imager was minimized through the adoption of a 2.4-mm diameter microelectromechanical systems (MEMS) scanning mirror, additionally a 12.7-mm diameter lens system was designed and combined with the MEMS mirror to achieve a small form factor that optimize functionality as a handheld extravascular OCT imager. To evaluate in-vivo applicability, super-microsurgical vessel anastomosis was performed in a mouse femoral vessel cut and repair model employing conventional interrupted suture technique as well as a novel non-suture cuff technique. Vascular anastomosis patency after clinically successful repair was evaluated using the novel handheld OCT imager.

Results

With an adjustable lateral image field of view up to 1.5 mm by 1.5 mm, high-resolution simultaneous structural and flow imaging of the blood vessels were successfully acquired for BALB/C mouse after orthotopic hind limb transplantation using a non-suture cuff technique and BALB/C mouse after femoral artery anastomosis using a suture technique. We experimentally quantify the axial and lateral resolution of the OCT to be 12.6 µm in air and 17.5 µm respectively. The OCT has a sensitivity of 84 dB and sensitivity roll-off of 5.7 dB/mm over an imaging range of 5 mm. Imaging with a frame rate of 36 Hz for an image size of 1000(lateral)×512(axial) pixels using a 50,000 A-lines per second swept source was achieved. Quantitative vessel lumen patency, lumen narrowing and thrombosis analysis were performed based on acquired structure and Doppler images.

Conclusions

A miniature handheld OCT imager that can be used for intraoperative evaluation of microvascular anastomosis was successfully demonstrated.  相似文献   

7.
Exercise training reverses endothelial dysfunction, but the effect in young, healthy subjects is less clear. We determined the influence of maximal oxygen uptake (VO2max) and a single bout of high-intensity exercise on flow-mediated dilatation (FMD), brachial artery diameter, peak blood flow, nitric oxide (NO) bioavailability, and antioxidant status in highly endurance-trained men and their sedentary counterparts. Ten men athletes (mean +/- SEM age 23.5 +/- 0.9 years, height 182.6 +/- 2.4 cm, weight 72.5 +/- 2.4 kg, VO2max 75.9 +/- 0.8 mL.kg.min) and seven healthy controls (age 25.4 +/- 1.2 years, height 183.9 +/- 3.74 cm, weight 92.8 +/- 3.9 kg, VO2max 47.7 +/- 1.7 mL.kg.min) took part in the study. FMD, brachial artery diameter, and peak blood flow were measured using echo-Doppler before, 1 hour, 24 hours, and 48 hours after a single bout of interval running for 5 x 5 minutes at 90% of maximal heart rate. NO bioavailability and antioxidant status in blood were measured at all time points. Maximal arterial diameter and peak flow were 10-15% (P < 0.02) and 28-35% (P < 0.02) larger, respectively, in athletes vs. controls at all time points, and similar FMD were observed, apart from a transient decay of FMD in athletes 1 hour post exercise. NO bioavailability increased significantly after exercise in both groups and decreased to baseline levels after 24 hours in controls but remained increased 80% and 93% above baseline 24 and 48 hours post exercise in athletes. Antioxidant status was equal in the two groups at baseline and increased by approximately 10% 1 hour post exercise, an effect that lasted for 24 hours. Athletes had larger arterial diameter but similar FMD as untrained subjects, i.e., athletes had larger capacity for blood transport compared with their untrained counterparts. The observed FMD, bioavailability of NO, and antioxidant status in blood were highly dependent on the time elapsed after the exercise session.  相似文献   

8.
Plaque rupture is the leading cause of acute coronary syndromes and stroke. Plaque formation, otherwise known as stenosis, preferentially occurs in the regions of arterial bifurcation or curvatures. To date, real-time assessment of stenosis-induced flow reversal remains a clinical challenge. By interfacing microelectromechanical system (MEMS) thermal sensors with the high frequency pulsed wave (PW) Doppler ultrasound, we proposed to assess flow reversal in the presence of an eccentric stenosis. We developed a 3-D stenotic model (inner diameter of 6 mm, an eccentric stenosis with a height of 2.75 mm, and width of 21 mm) simulating a superficial arterial vessel. We demonstrated that heat transfer from the sensing element (2×80 μm2) to the flow field peaked as a function of flow rates at the throat of the stenosis along the center/midline of arterial model, and dropped downstream from the stenosis, where flow reversal was detected by the high frequency ultrasound device at 45 MHz. Computational fluid dynamics (CFD) codes are in agreement with the ultrasound-acquired flow profiles upstream, downstream, and at the throat of the stenosis. Hence, we characterized regions of eccentric stenosis in terms of changes in heat transfer along the midline of vessel and identified points of flow reversal with high spatial and temporal resolution.  相似文献   

9.
The vascular endothelium is a monolayer of cells that cover the interior of blood vessels and provide both structural and functional roles. The endothelium acts as a barrier, preventing leukocyte adhesion and aggregation, as well as controlling permeability to plasma components. Functionally, the endothelium affects vessel tone.Endothelial dysfunction is an imbalance between the chemical species which regulate vessel tone, thombroresistance, cellular proliferation and mitosis. It is the first step in atherosclerosis and is associated with coronary artery disease, peripheral artery disease, heart failure, hypertension, and hyperlipidemia.The first demonstration of endothelial dysfunction involved direct infusion of acetylcholine and quantitative coronary angiography. Acetylcholine binds to muscarinic receptors on the endothelial cell surface, leading to an increase of intracellular calcium and increased nitric oxide (NO) production. In subjects with an intact endothelium, vasodilation was observed while subjects with endothelial damage experienced paradoxical vasoconstriction.There exists a non-invasive, in vivo method for measuring endothelial function in peripheral arteries using high-resolution B-mode ultrasound. The endothelial function of peripheral arteries is closely related to coronary artery function. This technique measures the percent diameter change in the brachial artery during a period of reactive hyperemia following limb ischemia.This technique, known as endothelium-dependent, flow-mediated vasodilation (FMD) has value in clinical research settings. However, a number of physiological and technical issues can affect the accuracy of the results and appropriate guidelines for the technique have been published. Despite the guidelines, FMD remains heavily operator dependent and presents a steep learning curve. This article presents a standardized method for measuring FMD in the brachial artery on the upper arm and offers suggestions to reduce intra-operator variability.  相似文献   

10.
Construction of a confocal microscope for real-time x-y and x-z imaging   总被引:1,自引:0,他引:1  
We describe the construction of a simple 'real-time' laser-scanning confocal microscope, and illustrate its use for rapid imaging of elementary intracellular calcium signaling events. A resonant scanning galvanometer (8 kHz) allows x-y frame acquisition rates of 15 or 30 Hz, and the use of mirrors to scan the laser beam permits use of true, pin-hole confocal detection to provide diffraction-limited spatial resolution. Furthermore, use of a piezoelectric device to rapidly focus the objective lens allows axial (x-z) images to be obtained from thick specimens at similar frame rates. A computer with image acquisition and graphics cards converts the output from the microscope to a standard video signal, which can then be recorded on videotape and analyzed by regular image processing systems. The system is largely made from commercially available components and requires little custom construction of mechanical parts or electronic circuitry. It costs only a small fraction of that of comparable commercial instruments, yet offers greater versatility and similar or better performance.  相似文献   

11.
摘要 目的:探讨彩色多普勒超声诊断不同病程老年2型糖尿病(T2DM)下肢血管病变(LEADDP)的临床价值及与血清内皮素(ET)、一氧化氮(NO)的关系。方法:选取我院于2019年5月~2020年4月期间收治的80例老年T2DM合并LEADDP患者为观察组,根据不同病程分为3组,<10年组30例,10~20年组33例,>20年组17例,另选取同时期我院收治的50名老年单纯T2DM患者为对照组,所有受检者均接受彩色多普勒超声检查,并检测血清ET、NO水平。对比观察组与对照组足背动脉狭窄发生率,对比不同病程患者LEADDP检出率,对比不同病程患者及对照组的动脉血管内径、动脉血流量及血清ET、NO水平,Pearson相关性分析动脉血管内径、动脉血流量与血清ET和NO水平的相关性。结果:观察组足背动脉狭窄发生率明显高于对照组(P<0.05);不同病程患者LEADDP检出率随着病程延长而增加(P<0.05);不同病程患者动脉血管内径、动脉血流量、NO水平随着病程的的延长而降低,ET水平随着病程的延长而升高(P<0.05);Pearson相关性分析显示,动脉血管内径、动脉血流量与血清ET水平呈负相关,与NO水平呈正相关(P<0.05)。结论:老年T2DM合并LEADDP患者存在明显的下肢动脉管径狭窄和血流量缓慢,病变程度随着病程延长而增加,与血清ET、NO水平有密切关系,彩色多普勒超声诊断可有效评价其病变程度。  相似文献   

12.
The purpose of the present study was to investigate the contribution of basal nitric oxide (NO) on retinal vascular tone in humans. In addition, we set out to elucidate the role of NO in flicker-induced retinal vasodilation in humans. Twelve healthy young subjects were studied in a three-way crossover design. Subjects received an intravenous infusion of either placebo or NG-monomethyl-L-arginine (L-NMMA; 3 or 6 mg/kg over 5 min), an inhibitor of NO synthase. Thereafter, diffuse luminance flicker was consecutively performed for 16, 32, and 64 s at a frequency of 8 Hz. The effect of L-NMMA on retinal arterial and venous diameter was assessed under resting conditions and during the hyperemic flicker response. Retinal vessel diameter was measured with a Zeiss retinal vessel analyzer. L-NMMA significantly reduced arterial diameter (3 mg/kg: -2%; 6 mg/kg: -4%, P < 0.001) and venous diameter (3 mg/kg: -5%; 6 mg/kg: -8%, P < 0.001). After placebo infusion, flicker induced a significant increase in retinal vessel diameter (P < 0.001). At a flicker duration of 64 s, arterial diameter increased by 4% and venous diameter increased by 3%. L-NMMA did not abolish these hyperemic responses but blunted venous vasodilation (P = 0.017) and arterial vasodilation (P = 0.02) in response to flicker stimulation. Our data indicate that NO contributes to basal retinal vascular tone in humans. In addition, NO appears to play a role in flicker-induced vasodilation of the human retinal vasculature.  相似文献   

13.
A new, continuous, on-line, video diameter-measuring technique, utilizing a video camera mounted on the sidearm of a stereo microscope, is described. Vessel diameter is derived from changes in the video output signal of the camera or a video recorder when the vessel of interest is displayed horizontally on a monitor and well contrasted with its background. A comparator threshold is set on the filtered video output signal and generates an output pulse that is used to gate horizontal video sync pulses to a digital counter-timer. The number of pulses counted for each video field (no. of horizontal video lines) is proportional to the vessel diameter. The video-derived diameter is calibrated using known standards and correlates well with sonomicrometer-derived diameters of the carotid artery and jugular vein during increasing pressure ramps (r greater than 0.999). The diameter update rate is 60 Hz, and the resolution of the system is one horizontal video line, independent of the vessel size. With suitable magnification and contrast both arteries and veins as small as 200 micron have been measured using this system.  相似文献   

14.
In repetitive measurements of flow-mediated dilatation (FMD), the duration of the interval between measurements remains controversial. In this pilot study, we conducted three sequential measurements of low–flow-mediated constriction (L-FMC), FMD and flow-mediated total dilation (FMTD; L-FMC+ FMD) at baseline and intervals of 15 and 60 min in 30 healthy males. FMD15, L-FMC15, and FMTD15 were significantly lower than the respective first measurements, but all indices showed full recovery at 60 min in all subjects. The baseline diameter was slightly increased at 15 min and restored at 60 min, but the maximum diameter, and the baseline and reactive flow velocity unchanged. We examined the relationship between recovery rate of FMTD at 15 min (FMTD-R) and cardio-ankle vascular index (CAVI). Univariate analysis showed moderate correlation between FMTD-R, and CAVI and L-FMC0. Patients were divided according to FMTD-R value; the low-FMTD-R group [below the median value (−26.2%)] included a significantly higher proportion of smokers and higher CAVI values than the high-FMTD-R group. The reproducibility of FMTD and FMTD-R was evaluated in another group of 25 healthy subjects. The range of variation across measurements was 1.1% for FMTD and 4.6% for FMTD-R; with intraclass correlation coefficients of 0.93 and 0.95, respectively. The present study demonstrated blunted recovery of FMD within 15 min, suggesting the need for selection of a more adequate interval between measurements to avoid underestimation of FMD in subsequent measurements. The findings demonstrated the reproducibility of FMTD-R and FMTD measurements, and that FMTD-R might be involved in arterial stiffness and early vascular impairment in the healthy subjects.  相似文献   

15.
Extreme inactivity of the legs in spinal cord-injured (SCI) individuals does not result in an impairment of the superficial femoral artery flow-mediated dilation (FMD). To gain insight into the underlying mechanism, the present study examined nitric oxide (NO) responsiveness of vascular smooth muscles in controls and SCI subjects. In eight healthy men (34 +/- 13 yr) and six SCI subjects (37 +/- 10 yr), superficial femoral artery FMD response was assessed by echo Doppler. Subsequently, infusion of incremental dosages of sodium nitroprusside (SNP) was used to assess NO responsiveness. Peak diameter was examined on a second day after 13 min of arterial occlusion in combination with sublingual administration of nitroglycerine. Resting and peak superficial femoral artery diameter in SCI subjects were smaller than in controls (P < 0.001). The FMD response in controls (4.2 +/- 0.9%) was lower than in SCI subjects (8.2 +/- 0.9%, P < 0.001), but not after correcting for area under the curve for shear rate (P = 0.35). When expressed as relative change from baseline, SCI subjects demonstrate a significantly larger diameter increase compared with controls at each dose of SNP. However, when expressed as a relative increase within the range of diameter changes [baseline (0%) - peak diameter (100%)], both groups demonstrate similar changes in response to SNP. Changes in diameter during SNP infusion and FMD response are larger in SCI subjects compared with controls. When these results are corrected, superficial femoral artery FMD and NO sensitivity in SCI subjects are not different from those in controls. This illustrates the importance of appropriate data presentation and suggests that, subsequent to structural inward remodeling of conduit arteries as a consequence of extreme physical inactivity, arterial function is normalized.  相似文献   

16.
Assessment of flow-mediated dilation (FMD) after forearm ischemia is widely used as a noninvasive bioassay of stimulated nitric oxide (NO)-mediated conduit artery vasodilator function in vivo. Whether this stimulated endothelial NO function reflects basal endothelial NO function is unknown. To test this hypothesis, retrospective analysis of randomized crossover studies was undertaken in 17 subjects with Type 2 diabetes; 9 subjects undertook an exercise training or control period, whereas the remaining 8 subjects were administered an angiotensin II receptor blocker or placebo. FMD was assessed by using wall tracking of high-resolution brachial artery ultrasound images in response to reactive hyperemia. Resistance vessel basal endothelium-dependent NO function was assessed by using intrabrachial administration of NG-monomethyl-L-arginine (L-NMMA) and plethysmographic assessment of forearm blood flow (FBF). FMD was higher after intervention compared with control/placebo (6.15+/-0.53 vs. 3.81+/-0.72%, P<0.001). There were no significant changes in the FBF responses to L-NMMA. Regression analysis between FMD and L-NMMA responses at entry to the study revealed an insignificant correlation (r=-0.10, P=0.7), and improvements in FMD with the interventions were not associated with changes in the L-NMMA responses (r=-0.04, P=0.9). We conclude that conduit artery-stimulated endothelial NO function (FMD) does not reflect basal resistance vessel endothelial NO function in subjects with Type 2 diabetes.  相似文献   

17.
Exercise training improves vascular function in subjects with cardiovascular disease and risk factors, but there is mounting evidence these vascular adaptations may be vessel bed specific. We have therefore examined the hypothesis that exercise-induced improvements in conduit vessel function are related to changes in resistance vessel function. Endothelium-dependent and -independent conduit vessel function were assessed by using wall-tracking of high-resolution brachial artery ultrasound images of the response to flow-mediated dilation (FMD) and nitroglycerine [glyceryl trinitrate (GTN)] administration. Resistance vessel endothelium-dependent and -independent function were assessed using intrabrachial administration of acetylcholine (ACh) and nitroprusside (SNP). Randomized crossover studies of 8-wk exercise training were undertaken in untreated hypercholesterolemic (n = 10), treated hypercholesterolemic (n = 10), coronary artery disease (n = 8), and Type 2 diabetic subjects (n = 15). Exercise training significantly enhanced responses to ACh (P < 0.05) and FMD (P < 0.0001). There were no significant changes in either SNP or GTN responses. The correlation between ACh and FMD responses at entry was not significant (r = 0.186; P = 0.231), and training-induced changes in the ACh did not correlate with those in FMD (r = -0.022; P = 0.890). Similarly, no correlation was evident between the SNP and GTN responses at entry (r = -0.010; P = 0.951) or between changes in these variables with training (r = -0.211; P = 0.191). We conclude that, although short-term exercise training improves endothelium-dependent nitric oxide-mediated vascular function in both conduit and resistance vessels, the magnitude of these improvements are unrelated.  相似文献   

18.
We tested the hypothesis that flow-mediated dilation (FMD) of the brachial artery would be impaired by acute increases in sympathetic nervous system activity (SNA) in models where similar peak shear stress stimulus was achieved by varying the duration of forearm muscle ischemia. Eleven healthy young men were studied under four different conditions, each with its own control: lower body suction (LBS), cold pressor test (CPT), mental arithmetic task (MAT), and activation of muscle chemoreflex (MCR). The duration of ischemia before observation of FMD by ultrasound imaging was 5 min each for control, LBS, and CPT; 3 min for MAT; and 2-min for MCR. Peak shear rate was not different between control and any of the SNA conditions, although total shear in the first minute was reduced in MAT. MCR was the only condition in which brachial artery vasoconstriction was observed before forearm occlusion [4.38 (SD 0.53) vs. control 4.60 (SD 0.53) mm, P < 0.05]; however, diameter increased to the same absolute value as that of the control, so the percent FMD was greater for MCR [9.85 (SD 2.33) vs. control 5.29 (SD 1.50)%]. Blunting of the FMD response occurred only in the CPT model [1.51 (SD 1.20)%]. During SNA, the increase in plasma cortisol from baseline was significant only for MCR; the increase in plasma norepinephrine was significant for MCR, LBS, and CPT; and the increase in epinephrine was significant only for MCR. These results showed that the four models employed to achieve increases in SNA had different effects on baseline brachial artery diameter and that blunted FMD is not a general response to increased SNA.  相似文献   

19.
A study is described in which the effects of hemodynamics on arterial geometry are investigated in vitro. A novel perfusion apparatus is employed to deliver pulsatile flow through excised canine carotid arteries under carefully controlled conditions. Data of perfused vessel diameter and arterial wall thickness are derived from the radial displacement of the pulsating vessel as measured using a scanning laser micrometer whose accuracy is determined to be 0.0125 mm (0.0005 in). The results of 30 perfusion experiments suggest that the hemodynamic variables of transmural pressure, pulse pressure and flow rate influence vessel size and radial strain. The physiologic implications of these findings are discussed.  相似文献   

20.
We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a) the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b) the first wearable system offering both large FOV and microscopic imaging simultaneously, (c) the first wearable system that offers both ultrasound imaging and fluorescence imaging capacities, and (d) the first demonstration of goggle-to-goggle communication to share stereoscopic views for medical guidance.  相似文献   