首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The recovery of low numbers of Escherichia coli O157 in foods by immunomagnetic separation (IMS) was improved, on average, ninefold by increasing the enrichment volume tested from 1 to 10 ml while maintaining the volume of immunobeads constant at 0.02 ml. Although 50 ml volumes also gave improved recoveries (approximately threefold), the 50 ml volume cannot be recommended until a suitable magnetic separation apparatus has been developed. By testing 10 ml volumes, the improved sensitivity of the IMS procedure will reduce false-negative E. coli O157 tests and help improve epidemiological studies of this pathogen.  相似文献   

2.
A.R. BENNETT, S. MACPHEE AND R.P. BETTS. 1996. The use of immunomagnetic separation (IMS) techniques has been reported to reduce the total test time, and improve the sensitivity, of microbiological tests done on foods. This approach is being adopted in epidemiological investigations into suspected foodborne outbreaks of Escherichia coli O157 infection and has gained acceptance by public health laboratories and the food industry. This study demonstrated the ability of a commercially available IMS procedure, Dynabeads anti- E. coli O157, to enable detection of a few cells of E. coli O157 in 25 g of inoculated minced beef, giving results 1 d earlier than a cultural analysis of similar sensitivity. With correct choice of enrichment broths, IMS may increase isolation rate of E. coli O157 compared to that obtained using conventional cultural methods. It is suggested that this may be due to an increase in relative concentration of E. coli O157 compared with the background microflora present in minced beef, which may reduce reliability of non-IMS detection procedures by masking or mimicking target cells on selective/differential solid media. The use of an immunoassay incorporating an IMS step, EHEC-Tek (Organon-Teknika), enabled detection of a few cells of E. coli O157 in 25 g of minced beef. Comparison of the IMS-ELISA with a standard ELISA procedure (Tecra) indicated the sensitivity of the latter system to be greater, perhaps resulting in the higher isolation rate. The use of a method to reliability isolate and detect extremely low levels of E. coli O157 in a food is necessary to aid reduction in the incidence of this most serious of foodborne pathogens.  相似文献   

3.
AIMS: To compare media used in immunomagnetic separation (IMS) techniques for the isolation of Escherichia coli O157 from food. METHODS AND RESULTS: Foods, both naturally contaminated and spiked, with low numbers (< 1 g(-1)) of stressed E. coli O157 were enriched in media based on buffered peptone water (BPW), tryptone soya and EC broths incubated at 30, 37, 40 and 42 degrees C. Following immunomagnetic separation, beads were plated on a range of selective agars. CONCLUSION: BPW supplemented with vancomycin (8 mg l(-1)) incubated at 42 degrees C, followed by IMS and subsequent plating of immunobeads onto cefixime tellurite sorbitol MacConkey agar plus either Rainbow or CHROMagar agars, proved optimum for the recovery of spiked, stressed E. coli O157 in minced beef, cheese, apple juice and pepperoni. The same protocol was optimum for recovery from naturally-contaminated minced beef and cheese. SIGNIFICANCE AND IMPACT OF THE STUDY: The optimum protocol would increase isolation rates of E. coli O157 from foods.  相似文献   

4.
AIMS: The detection of Escherichia coli O157:H7 in environmental samples is a human concern. The high persistence of this serotype in the environment suggests that contaminated animal wastewater could act as a potential reservoir. Nevertheless, the high levels of background microflora and cell damage because of environmental stress hamper the isolation of this pathogen without using enrichment methods. This study develops a method for the detection of E. coli and investigates its prevalence in animal and human wastewaters. METHODS AND RESULTS: Incubation of the sample for 1 h 30 min at 37 degrees C in peptone water supplemented with vancomycin and cefsulodin, enhanced the recovery of bacteria whilst ensuring that no growth occurred. Subsequently, a combination of immunomagnetic separation, cefixime-tellurite-sorbitol MacConkey (CT-SMAC) plating and immunoblotting with specific O157 antibodies allowed the detection, enumeration and isolation of E. coli O157 strains in human, swine and cattle wastewaters, which presented values of 0.2, 0.4, and 1.0 log10 ml(-1) units, respectively. Some of the isolates carried genes coding for Shiga toxins, intimin and enterohemolysin. CONCLUSIONS: Escherichia coli O157 is commonly present in animal and human wastewaters. The developed method reduced the high rate of false positives reported for other technical approaches. SIGNIFICANCE AND IMPACT OF THE STUDY: The confirmation of serotype by specific immunomethods is necessary to prevent false-positive detection and incorrect enumeration.  相似文献   

5.
An assay system for detection of Escherichia coli O157:H7 was developed based on immunomagnetic separation of the target pathogen from samples and absorbance measurement of p-nitrophenol at 400 nm from p-nitrophenyl phosphate hydrolysis by alkaline phosphatase (EC 3.1.3.1) on the "sandwich" structure complexes (antibodies coated onto micromagnetic beads--E. coli O157:H7-antibodies conjugated with the enzyme) formed on the microbead surface. The effects of immunoreaction time, phosphate buffer concentration, pH and temperature on the immunomagnetic separation of E. coli O157:H7 from samples were determined and the conditions used for the separation were 1-h reaction time, 1.0 x 10(-2) M PBS, pH 8.0 and 33 degrees C in this system. The effects of MgCl(2) concentration, Tris buffer concentration, pH and temperature on the activity of alkaline phosphatase conjugated on the immuno-"sandwich" structure complexes were investigated after immunomagnetic separation of the target pathogen and the conditions used for the enzymatic amplification were 1.0 x 10(-4) M MgCl(2), 1.0 M Tris buffer, pH 8.0, 28 degrees C and 30-min reaction time during the assay. The selectivity of the system was examined and no interference from the other pathogens including Salmonella typhimurium, Campylobacter jejuni and Listeria monocytogenes was observed. Its working range was from 3.2 x 10(2) to 3.2 x 10(4) CFU/ml, and the relative standard deviation was 2.5-9.9%. The total detection time was less than 2 h.  相似文献   

6.
The aim of this research was to elaborate fast and sensitive method ofdetection of E. coli O157:H7 in food samples. Raw ground meat obtained from retail was artificially inoculated with low numbers of E. coli O157:H7. 18 h enrichment culture allowed pathogenic bacteria to multiply to the levels detectable in multiplex PCR. Immunomagnetic separation with magnetic beads coated with an antibody against E. coli O157:H7 were used to concentrate target bacteria and to separate PCR inhibitors. A portion of the bacterial suspension was used in a multiplex PCR to amplify eae (attaching and effacing) gene, stx (shiga toxin) genes and 90 kbp plasmid. The sensitivity of E. coli O157:H7 detection method was shown to be 1 cfu per 25 g of food sample. The total analysis can be completed within 24 h, whilst traditional methods involves enrichment, direct plating and confirmation tests with entire time at least 3 days.  相似文献   

7.
AIMS: To develop improved methods for the detection of Escherichia coli O157 from water and sediments. METHODS AND RESULTS: The effects of different broth enrichment media (unsupplemented tryptic soya broth, tryptic soya broth with antibiotics, and gram-negative broth), incubation durations (5 and 24 hrs), incubation temperatures (37 and 44.5 degrees C) and the use of immunomagnetic separation (IMS) on the sensitivity of E. coli O157 detection were evaluated on artificially and naturally-contaminated water and sediment samples. The sensitivity of recovery of E. coli O157 from samples was dependent upon the media composition, temperature duration of incubation and the use of IMS. CONCLUSION: Use of high temperature (44.5 degrees C) incubation for 24 hrs in unsupplemented tryptic soya broth and the use of IMS improved the sensitivity of E. coli O157 culture from water and sediment samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The methods described can be used to increase the sensitivity of E. coli O157 detection from water and sediments.  相似文献   

8.
C. VERNOZY-ROZAND, C. MAZUY, S. RAY-GUENIOT, S. BOUTRAND-LOEï, A. MEYRAND AND y. richard. 1997. Two commercially available screening methods, an automated enzyme-linked fluorescent immunoassay (VIDASTM E. coli O157) and an immunomagnetic separation followed by culture onto cefixime tellurite sorbitol MacConkey agar (CT-SMAC), were compared for detection of Escherichia coli O157 in naturally and artificially contaminated food samples. A total of 250 naturally contaminated food samples, including raw milk cheeses, poultry, raw sausages and ground beef retail samples, were examined. Four poultry, one raw sausage and one ground beef sample were found to be positive for E. coli O157 by both methods. Of the six positive samples, five were shown to contain sorbitol-positive, O157-positive, H7-negative, motile and non-verotoxin-producing E. coli .  相似文献   

9.
Sensitivities of direct plate culture (DPC) method, immunomagnetic separation (IMS) method, and polymerase chain reaction (PCR) assay for successful detection Escherichia coli O157 in the food samples were compared. Three lots of minced beef and three lots of radish sprout, both of which were commercially retailed, were enriched with non-selective broth media at 36 degrees C for 6 h. After enrichment, the cultures of the minced beef and those of the radish sprout were found to have background microflora at ca.10(5)-10(7) CFU/ml and ca.10(8) CFU/ml, respectively. The cultures were then experimentally inoculated with E. coli O157 strains at various final concentrations ranging from ca.10 to 10(7) CFU/ml. The samples thus prepared were subjected to the above three methods to evaluate their detection limits. For the samples of minced beef, the detection limits of the DPC method was 10(2) CFU/ml whilst that of the IMS method was ca.10 CFU/ml. For the samples of radish sprout, the detection limits of the DPC method, the IMS method, and the PCR assay were ca.10(4) CFU/ml, ca.10(2) CFU/ml, and ca.10(6) CFU/ml, respectively. There results strongly suggest that the IMS method is most sensitive method for the detection of O157 from food samples among the methods currently available.  相似文献   

10.
We found effective enrichment procedures for detecting Escherichia coli O26 in foods using methods that are used for E. coli O157. Ground beef or radish sprouts inoculated with approximately 6 colony-forming units of E. coli O26 were homogenized in 225 ml of various broths. After static incubation at 37 degrees C or 42 degrees C for 6 h or 18 h, we isolated the inoculated bacterium by plating onto Rainbow Agar O157 with novobiocin. In combination with the immunomagnetic separation method, E. coli O26 was isolated from all samples by using enrichment in tryptone soy broth at 37 degrees C for 6 h and in modified E. coli broth with novobiocin (mEC + n) at 42 degrees C for 18 h in ground beef and radish sprouts, respectively. Enrichment in mEC + n at 42 degrees C for 18 h was effective for isolating both E. coli O26 and E. coli O157 from both ground beef and radish sprouts.  相似文献   

11.
AIMS: To determine the numbers of Escherichia coli O157 present in the faeces of naturally infected cattle. METHODS AND RESULTS: A combination of the most probable number (MPN) technique and automated immunomagnetic separation (AIMS) was used to enumerate E. coli O157 in cattle faeces from both pasture-fed and grain-fed animals. A total of 22 E. coli O157 positive faecal samples were enumerated for E. coli O157 (10 from pasture-fed and 12 from grain-fed animals). The numbers of E. coli O157 in cattle faeces varied from undetectable (<3 MPN g-1 of faeces) to 2.4 x 104 MPN g-1. There was no significant difference (P = 0.06) between the numbers of E. coli O157 in pasture-fed or grain-fed cattle faeces, although the geometric mean (antilog of the mean of log10 transformed MPN values) was higher in grain-fed (130 MPN g-1) than in pasture-fed (13 MPN g-1). CONCLUSIONS: Although the number of samples tested is small, the results indicate that E. coli O157 make up a small proportion of the total E. coli population present in cattle faeces. SIGNIFICANCE AND IMPACT OF THE STUDY: Information on the numbers of E. coli O157 present in cattle will assist in developing more robust quantitative risk assessments and formulating intervention strategies.  相似文献   

12.
A commercial enzyme immunoassay (EIA) (E. coli O157 Visual Immunoassay; Tecra Diagnostics) performed on enrichment cultures in modified Escherichia coli broth (mECn) was compared with immunomagnetic separation (IMS) (Dynabeads anti-E. coli O157; Dynal) performed on enrichment cultures in modified buffered peptone water (BPW-VCC) for the detection of E. coli O157 in bovine fecal samples. Tests on fecal suspensions inoculated with each of 12 different strains of E. coli O157 showed that both the EIA and IMS methods were 10- to 100-fold more sensitive than direct culture or enrichment subculture methods for detection of the organism. EIA and IMS were then compared for detection of E. coli O157 in bovine rectal swabs. For confirmation of positive EIA tests, a commercial system (Immunocapture System [ICS]; Tecra Diagnostics) was compared with IMS; both were performed on mECn enrichment cultures. Of 200 rectal swabs examined, 17 gave positive results in the EIA which were confirmed by both confirmation systems, 2 gave positive results in the EIA which were confirmed by IMS but not by ICS, and 1 gave a positive result in the EIA which was confirmed by ICS but not by IMS. Of these 20, 15 were also positive by the BPW-VCC-IMS culture system; a further 3 samples were positive by this culture system but gave a negative result in the EIA. Eight samples were negative by the BPW-VCC-IMS culture system but gave a positive result in the EIA which could not be confirmed by either confirmation system. Further examination of the eight unconfirmed EIA-positive samples yielded sorbitol-fermenting E. coli O157 from three samples. Of the remaining five cultures, four were positive in an EIA for verocytotoxins (VT) and two were positive in a cell culture assay for VT1. The remaining 170 samples were negative by both EIA and BPW-VCC-IMS. The Tecra EIA and IMS are both technically simple and sensitive methods for detecting E. coli O157 in bovine fecal samples. There was no statistically significant difference between the numbers of positives detected by the different assays (P = 0.29).  相似文献   

13.
A protocol for the quantitative detection of Escherichia coli O157 in raw and concentrated surface waters using immunomagnetic electrochemiluminescence (IM-ECL) was developed and optimized. Three antibody sandwich formats were tested: commercial anti-O157:H7 IM beads, IM beads made in-house with a polyclonal anti-O157:H7 immunoglobulin G (IgG), or IM beads made in-house with a monoclonal anti-O157:H7 IgG coupled with a polyclonal anti-O157:H7 IgG to which an electrochemiluminescent label (TAG) was attached. The monoclonal IM bead-polyclonal TAG format was chosen for optimization because it gave lower background levels and linear regression slopes of ca. 1.0, indicative of a constant ECL signal per cell. The dynamic range was ca. 10(1) to 10(5) cells ml(-1) in phosphate-buffered saline and in raw water samples. The monoclonal IM beads selectively captured E. coli O157 cells in the presence of ca. 10(8) cells of a non-O157 strain of E. coli ml(-1). Background ECL signals from concentrated (100-fold) water samples were substantially higher and more variable than raw water samples. The background signal was partially eliminated by the addition of polyvinylpolypyrrolidone. Successive cell capture incubations, termed sequential bead capture (SBC), were optimized for establishing baseline ECL values for individual water samples. The linear dynamic range with SBC was ca. 10(2) to 10(5) E. coli O157 cells ml of concentrated water(-1). To validate the protocol, 10-liter surface water samples were spiked with ca. 5,000 E. coli O157 (Odwalla) cells and concentrated by vortex filtration, and 1- or 3-ml aliquots were analyzed by IM-ECL. Differential ECL signals (SBC) from 1- and 3-ml samples were statistically significant and were generally consistent with standard curves for these cell concentrations. Enrichments were conducted with aliquots of spiked raw water and concentrated water using EC broth and minimal lactose broth (MLB). All tubes with concentrated water became turbid and gave a positive ECL response for E. coli O157 (>10,000 ECL units); MLB gave a somewhat higher detection rate with spiked raw water. The potential sensitivity of the IM-ECL assay is ca. 25 E. coli O157 cells ml of raw water(-1), 25 cells 100 ml of 100-fold concentrated water(-1), or 1 to 2 viable cells liter(-1) with concentration and enrichment. The IM-ECL assay appears suitable for routine analysis and screening of water samples.  相似文献   

14.
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.  相似文献   

15.
AIMS: To compare the sensitivity of two pre-enrichment broth media prior to immunomagnetic separation for the isolation of Escherichia coli O157 from cattle faeces. METHODS AND RESULTS: One-gram portions of 721 cattle faeces collected from 43 farms were pre-enriched in buffered peptone water containing vancomycin, cefixime and cefsulodin (BPW-VCC) and buffered peptone water without additives (BPW-WOA), respectively. A total of 137 samples were positive for E. coli O157: 127 pre-enriched with BPW-WOA and 89 pre-enriched in BPW-VCC. Representative isolates were tested for phage type, verotoxin and eae (E. coli attaching and effacing) gene sequences, resulting in the recognition of eight different types. All the E. coli O157 types recognized were isolated by both methods except for three different strains, each of which were isolated only on a single occasion: two by BPW-WOA and another by BPW-VCC. CONCLUSIONS: The results clearly demonstrate, under the conditions of this study, that BPW without antibiotics was the superior pre-enrichment medium for the isolation of E. coli O157 from cattle faeces. SIGNIFICANCE AND IMPACT OF THE STUDY: The use of BPW-WOA in preference to BPW-VCC for the isolation of E. coli O157 from cattle faeces in future research and outbreak studies should lead to a higher number of positive isolates.  相似文献   

16.
AIMS: Escherichia coli O157 is considered to be one of most important human pathogens of animal origin which causes serious clinical complications. One of the most common methods to isolate E. coli O157 is the immunomagnetic separation (IMS) technique which employs specific antibodies coupled to magnetic beads to bind and extract cells from enrichment broths followed by plating onto sorbitol MacConkey agar supplemented with cefixime and potassium tellurite (CT-SMAC) plates. The aim of this study was to determine strain variation by pulsed-field gel electrophoresis (PFGE) among E. coli O157 on IMS/CT-SMAC plates. METHODS AND RESULTS: Every suspect colony of E. coli O157 was tested following isolation by the IMS/CT-SMAC technique. From 124 colonies detected; six XbaI-PFGE profiles were identified. CONCLUSIONS: Our results demonstrate that mixed populations of E. coli O157 with distinguishable PFGE profiles that are simultaneously present in bovine faeces can be isolated with IMS/CT-SMAC technique. SIGNIFICANCE AND IMPACT OF THE STUDY: If the aim of the study was to analyse diversity of PFGE profiles of E. coli O157 in a faecal sample following isolation by the IMS/CT-SMAC technique, at least five colonies per sample should be analysed to detect different PFGE subtypes if present.  相似文献   

17.
18.
We studied injury of Escherichia coli O157:H7 cells in 11 food items during freeze storage and methods of isolating freeze-injured E. coli O157:H7 cells from foods. Food samples inoculated with E. coli O157:H7 were stored for 16 weeks at -20 degrees C in a freezer. Noninjured and injured cells were counted by using tryptic soy agar and sorbitol MacConkey agar supplemented with cefixime and potassium tellurite. Large populations of E. coli O157:H7 cells were injured in salted cabbage, grated radish, seaweed, and tomato samples. In an experiment to detect E. coli O157:H7 in food samples artificially contaminated with freeze-injured E. coli O157:H7 cells, the organism was recovered most efficiently after the samples were incubated in modified E. coli broth without bile salts at 25 degrees C for 2 h and then selectively enriched at 42 degrees C for 18 h by adding bile salts and novobiocin. Our enrichment method was further evaluated by isolating E. coli O157:H7 from frozen foods inoculated with the organism prior to freezing. Two hours of resuscitation at 25 degrees C in nonselective broth improved recovery of E. coli O157:H7 from frozen grated radishes and strawberries, demonstrating that the resuscitation step is very effective for isolating E. coli O157:H7 from frozen foods contaminated with injured E. coli O157:H7 cells.  相似文献   

19.
AIMS: To compare immunomagnetic separation (IMS) protocols (enrichment media and temperature) for the isolation of Escherichia coli serotypes O26 and O111 from four different foods. METHODS AND RESULTS: Foods (minced beef, cheese, apple juice and pepperoni) spiked with low numbers (<100 g(-1)) of stressed nalidixic mutant E. coli serotypes O26 and O111 were enriched in media based on buffered peptone water (BPW), tryptone soya and EC broths incubated at temperatures of 37 and 42 degrees C to optimize the IMS technique. BPW enrichments gave increased recoveries of both serotypes compared with tryptone soya and EC broths. Elevated temperatures of incubation at 42 degrees C were superior to 37 degrees C. CONCLUSIONS: Positive detection of low numbers of stressed target pathogens in all replicate tests was only possible using BPW enrichments. The majority of tests from alternative enrichments resulted in zero or single colonies recovered post-IMS. SIGNIFICANCE AND IMPACT OF THE STUDY: The optimum IMS protocol would improve isolation rates of E. coli O26 and O111 from foods and lead to increased safety for the consumer. Sub-optimal IMS protocols could lead to foods being incorrectly labelled free from these pathogens.  相似文献   

20.
AIMS: To assess the detection and recovery rates achieved with commonly used cultural methods for the enumeration and recovery of Escherichia coli O157:H7 from minced beef and bovine hide. METHODS AND RESULTS: Minced beef and bovine hide were inoculated with varying concentrations (log(10) 1.58-2.58 CFU g(-1) and log(10) 2.42-4.49 CFU 100 cm(2) respectively) of E. coli O157:H7 and recovered using a direct plate method or an enrichment/immunomagnetic separation (IMS) method and then plated onto SMAC or SMAC-CT in both cases. The direct plate method detected the pathogen consistently from minced beef samples with an average recovery of 69.2-91.2%. From faecal material on the bovine hide the recovery of the pathogen ranged from 1.80 to 64.5% with fresh faeces depending on the inocula while from dried faeces on hide the results ranged from no recovery at all to 25.1%. Enrichment/IMS recovered E. coli O157:H7 at all inocula levels tested in minced beef while the pathogen was only detected consistently at an average inocula level of log(10) 2.73 CFU 100 cm(2) from fresh faeces and log(10) 4.49 CFU 100 cm(2) from dried faeces on bovine hide. CONCLUSIONS: The direct count enumeration method for E. coli O157:H7 underestimated the numbers of pathogens present. The enrichment/IMS procedure consistently detected the pathogen from minced beef but did not always detect E. coli O157:H7 from faeces on bovine hide. SIGNIFICANCE AND IMPACT OF THE STUDY: Overall this study highlights that any microbial data, used in either predictive microbiology or risk assessment, must take account of the sensitivity and associated performance of the methods employed, in order to make an accurate reflection of the true microbiology of the examined sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号