首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ifosfamide blood concentrations are necessary to monitor its therapeutic response, avoiding any adverse effect. We developed and validated an analytical method by UPLC-MS/MS to quantify ifosfamide in dried blood spots (DBS). Blood samples were collected on Whatman 903® filter paper cards. Five 3 mm disks were punched out from each dried blood spot. Acetonitrile and ethyl acetate were used for drug extraction. Chromatographic separation was carried out in an Acquity UPLC equipment with a BEH-C18 column, 2.1 x 100 mm, 1.7 μm (Waters®). The mobile phase consisted in 5 mM ammonium formate and methanol:acetonitrile (40:48:12 v/v/v) at 0.2 mL/min. LC-MS/MS detection was done by ESI+ and multiple reaction mode monitoring, ionic transitions were m/z1+ 260.99 > 91.63 for ifosfamide and 261.00 > 139.90 for cyclophosphamide (internal standard). This method was linear within a 100–10000 ng/mL range and it was accurate, precise and selective. Ifosfamide samples in DBS were stable for up to 52 days at -80°C. The procedure was tested in 14 patients, ages 1 month to 17 years (9 males and 5 females), with embryonic tumours treated with ifosfamide, alone or combined, at a public tertiary referral hospital. Ifosfamide blood levels ranged from 11.1 to 39.7 μmol/L at 12 hours after the last infusion, while 24-hour levels ranged from 0.7–19.7 μmol/L. The median at 12 hours was 19.5 μmol/L (Q25 14.4–Q75 29.0) and 3.8 μmol/L (Q25 1.5–Q75 9.9) at 24 hours, p<0.001. This method is feasible to determine ifosfamide plasma levels in paediatric patients.  相似文献   

2.
A sensitive, specific and precise HPLC–UV assay was developed to quantitate cocaine (COC) and its metabolites benzoylecgonine (BE), norcocaine (NC) and cocaethylene (CE) in rat plasma. After adding 50 μl of the internal standard solution (bupivacaine, 8 μg/ml) and 500 μl of Sørensen's buffer (pH 6) to 100 μl of rat plasma sample, the mixture was extracted with 10 ml of chloroform. The organic layer was transferred to a clean test tube and was evaporated under nitrogen. The residue was reconstituted in 100 μl of mobile phase and 35 μl was injected onto the HPLC column. The mobile phase consisted of methanol–acetonitrile–50 mM monobasic ammonium phosphate (5:7:63, v/v/v) and was maintained at a flow-rate of 0.4 ml/min. Separation of COC and its metabolites was achieved using a Supelcosil ABZ+plus deactivated reversed-phase column (250×2.1 mm I.D., 5 μm). Calibration curves were linear over the range of 25–5000 ng/ml for COC and its three metabolites. The absolute extraction efficiencies for BE, COC, NC, CE and bupivacaine were 56.6%, 78.6%, 61.1%, 76.4% and 67.0%, respectively. COC and its metabolites were stable in mobile phase for 24 h at room temperature and in rat plasma for 2 weeks at −20°C. The limits of detection for BE, COC, NC and CE were 20, 24, 15 and 12.9 ng/ml, respectively. These values correspond to 0.70, 0.84, 0.525 and 0.452 ng of the according compound being injected on column. The within-day coefficient of variation for the four compounds ranged from 3.0% to 9.9% while the between-day precision varied from 3.6% to 14%. This method was used to analyze rat plasma samples after administration of COC alone and in combination with alcohol. The pharmacokinetic profiles of COC and its metabolites in these rats are also described.  相似文献   

3.
A facile, sensitive and highly specific HPLC method for assaying 1-(2-chloroethyl)-3-sarcosinamide-1-nitrosourea (SarCNU) in plasma has been developed. The drug was efficiently isolated from plasma by extraction with tert.-butyl methyl ether. A structurally related compound with similar physicochemical properties served as the internal standard (I.S.). Following evaporation of the organic solvent, the extract was reconstituted with 0.05 M ammonium acetate buffer, pH 5.0, and loaded onto a 4 μm Nova-Pak C18 column (15 cm×3.9 mm), which was preceded by a 7 μm Brownlee RP-18 precolumn (1.5 cm×3.2 mm). Chromatography was performed at ambient temperature using a mobile phase of methanol-0.1 M ammonium formate buffer, pH 3.7 (25:75, v/v). UV absorbance of the effluent was monitored at 240 nm. A flow-rate of 1.0 ml/min was used for analyzing mouse and dog plasma extracts. Under these conditions, the drug eluted at 4.0 min and was followed by the I.S. at 6.1 min. An automatic switching valve was employed to allow the precolumn to be flushed 1.5 min into the run, without interrupting the flow of the mobile phase to the analytical column, thereby preventing the apparent build-up of extractable, strongly retained, UV-absorbing components present in mouse and dog plasma. Operating in this manner, more than 100 samples could be analyzed during a day using a refrigerated autosampler for overnight injection. The method was readily adapted to the determination of SarCNU in human plasma by simply decreasing the eluent flow-rate to 0.6 ml/min, whereby SarCNU and the I.S. eluted at approximately 5.8 and 9.1 min, respectively. Furthermore, the switching valve was not necessary for the analysis of human plasma samples. With a 50-μl sample volume, the lowest concentration of SarCNU included in the plasma standard curves, 0.10 μg/ml, was quantified with a 7.8% R.S.D. (n=27) over a 2 month period. Plasma standards, with concentrations of 0.26 to 5.1 μg/ml, exhibited R.S.D. values ranging from 1.3 to 4.7%. Thermospray-ionization MS detection was used to definitively establish the specificity of the method. The sensitivity of the assay was shown by application to be more than adequate for characterizing the plasma pharmacokinetics of SarCNU in mice.  相似文献   

4.
A single-solvent extraction step high-performance liquid chromatographic method is described for quantitating zolpidem in rat serum microsamples (50 μl). The separation used a 2.1 mm I.D. reversed-phase OD-5-100 C18 column, 5 μm particle size with an isocratic mobile phase consisting of methanol–acetonitrile–26 mM sodium acetate buffer (adjusted to pH 2.0 with 40% phosphoric acid) containing 0.26 mM tetrabutylammonium phosphate (13:10:77, v/v/v). The detection limit was 3 ng/ml for zolpidem using an ultraviolet detector operated at 240 nm. The recovery was greater than 87% with analysis performed in 12 min. The method is simple, rapid, and applicable to pharmacokinetic studies of zolpidem after administering two intravenous bolus doses (1 and 4 mg/kg) in rats.  相似文献   

5.
A sensitive, selective and simple HPLC method with fluorimetric detection is described for quantitating cocaine and its three metabolites in rat serum microsamples (50 μl). Chromatographic separation is achieved on a Hypersil BDS C18 column (100×2.1 mm, 5 μm) with an isocratic mobile phase consisting of methanol–acetonitrile–25.8 mM sodium acetate buffer, pH 2.6, containing 1.0·10−4 M tetrabutylammonium phosphate (14:10:76, v/v/v). The detection limit (0.5 ng/ml) for all the compounds, using direct fluorometric detection operated at excitation and emission wavelengths of 230 and 315 nm, respectively, was approximately five-times lower than that of using a UV detector operated at 235 nm. The effects of ratio of 2-propanol to chloroform in extraction solvents on the recovery and precision for cocaine and its metabolites were systematically examined. The method was used to study the pharmacokinetics of cocaine after administration of intravenous 2 mg/kg and oral 20 mg/kg doses.  相似文献   

6.
A study, using on-line column-switching high-performance liquid chromatography, evaluated two different extraction columns for the determination of flunitrazepam and its major metabolites: 7-aminoflunitrazepam, 7-acetamidoflunitrazepam and desmethylflunitrazepam. The procedure was based on the enrichment of benzodiazepines on the extraction column, followed by transfer of the compounds to the analytical column. The two extraction columns were compared: the first column was a BioTrap 500 MS (hydrophobic polymer), 20×4 mm I.D., and the second was a LiChrospher RP-18 ADS, 25×4 mm I.D. The analytical column used was a LiChrospher select B RP-8, 125×3 mm I.D. with 5 μm particle size. The extraction conditions for the two pre-concentration columns, such as extraction temperature, buffer concentration, buffer pH, acetonitrile percentage and flow-rate, were studied for the extraction from plasma of flunitrazepam and its metabolites mentioned above. The mobile phase of the analytical column was isocratic and composed of acetonitrile–20 mM phosphate buffer at pH 2.1 (35:65, v/v) and at a flow-rate of 0.3 ml/min.  相似文献   

7.
A simple, rapid and reliable method was developed for the quantification of oxymatrine (OMT) and its metabolite matrine (MT) in beagle dog plasma using a liquid-liquid extraction procedure followed by liquid chromatography-electrospray ionization mass spectrometric (LC-ESI-MS) analysis. Extend-C18 column (2.1 mm i.d. x 50 mm, 5 microm) with a C18 guard column (2.1 mm i.d. x 12.5 mm) was used as the analytical column. Linear detection responses were obtained for OMT concentration ranging from 5 to 4000 ng/ml and for MT concentration ranging from 5 to 2000 ng/ml. The precision and accuracy data, based on intra- and inter-day variations over 5 days, were lower than 5%. The limit of quantitation for OMT and MT were 2 and 1 ng/ml, respectively, and their recoveries were greater than 90%. Pharmacokinetic data of OMT and its active metabolite MT obtained with this method following a single oral dose of 300 mg OMT capsules to six beagle dogs was also reported for the first time.  相似文献   

8.
Methods for the determination of celecoxib in human plasma and rat microdialysis samples using liquid chromatography tandem mass spectrometry are described. Celecoxib and an internal standard were extracted from plasma by solid-phase extraction with C18 cartridges. Thereafter compounds were separated on a short narrow bore RP C18 column (30×2 mm). Microdialysis samples did not require extraction and were injected directly using a narrow bore RP C18 column (70×2 mm). The detection was by a PE Sciex API 3000 mass spectrometer equipped with a turbo ion spray interface. The compounds were detected in the negative ion mode using the mass transitions m/z 380→316 and m/z 366→302 for celecoxib and internal standard, respectively. The assay was validated for human plasma over a concentration range of 0.25–250 ng/ml using 0.2 ml of sample. The assay for microdialysis samples (50 μl) was validated over a concentration range of 0.5–20 ng/ml. The method was utilised to determine pharmacokinetics of celecoxib in human plasma and in rat spinal cord perfusate.  相似文献   

9.
Our laboratory originally synthesized strontium(Sr)‐containing α‐calcium sulphate hemihydrate/nano‐hydroxyapatite composite (Sr‐α‐CSH/n‐HA) and demonstrated its ability to repair critical bone defects. This study attempted to incorporate aspirin into it to produce a better bone graft material for critical bone defects. After 5% Sr‐α‐CSH was prepared by coprecipitation and hydrothermal methods, it was mixed with aspirin solution of different concentrations (50 μg/ml, 200 μg/ml, 800 μg/ml and 3200 μg/ml) at a fixed liquid‐solid ratio (0.54 v/w) to obtain aspirin‐loaded Sr‐α‐CSH/n‐HA composite. In vitro experiments were performed on the composite extracts. The tibial defects (3 mm*5 mm) in SD rat model were filled with the composite for 4 weeks and 12 weeks to evaluate its osteogenic capacity in vivo. Our results showed its capability of proliferation, migration and osteogenesis of BMSCs in vitro got improved. In vivo treatment with 800 μg/ml aspirin–loaded Sr‐α‐CSH/n‐HA composite led to significantly more new bone formation in the defects compared with Sr‐α‐CSH/n‐HA composite and significantly promoted the expression of osteogenic‐related genes and inhibited osteoclast activity. In general, our research suggests that aspirin‐loaded Sr‐α‐CSH/n‐HA composite may have a greater capacity of repairing tibial defects in SD rats than simple Sr‐α‐CSH/n‐HA composite.  相似文献   

10.
This study describes a sensitive HPLC–electrochemical detection method for the analysis of ceftazidime, a third-generation cephalosporin, in human plasma. The extraction procedure involved protein precipitation with 30% trichloroacetic acid. The separation was achieved on a reversed-phase column (250×4.6 mm I.D., 5 μm) packed with C18 Kromasil with isocratic elution and a mobile phase consisting of acetonitrile–25 mM KH2PO4–Na2HPO4 buffer, pH 7.4 (10:90, v/v). The proposed analytical method is selective, reproducible and reliable. The assay has a precision of 0.2–15.1% (C.V.) in the range of 5–200 μg ml−1. (corresponding to 0.5 to 20 ng of ceftazidime injected onto the column), and is optimised for assaying 50 μl of plasma. The extraction recovery from plasma was approximately 100%. The method was highly specific for ceftazidime and there was no interference from either commonly administered drugs or endogenous compounds. This assay was used to measure ceftazidime in elderly patients for therapeutic drug monitoring.  相似文献   

11.
A simple high-performance liquid chromatographic method was developed to study the pharmacokinetics of dicentrine in rat plasma after 10 mg/kg intravenous administration. After addition of an internal standard (coumarin), plasma was deproteinized by acetonitrile for sample clean-up. The drugs were separated on a reversed-phase Nucleosil C18 column (250 × 4 mm I.D., particle size 5 μm) and detected by photodiode-array detection at a wavelength of 308 nm. Acetonitrile-water (35:65, v/v, pH 2.5–2.8, adjusted with orthophosphoric acid) was used as the mobile phase. A biphasic phenomenon with a rapid distribution followed by a slower elimination phase was observed from the plasma concentration-time curve.  相似文献   

12.

Background

Pericardial fluid (PF) contains several biologically active substances, which may provide information regarding the cardiac conditions. Nitric oxide (NO) has been implicated in cardiac remodeling. We hypothesized that L-arginine (L-Arg) precursor of NO-synthase (NOS) and asymmetric dimethylarginine (ADMA), an inhibitor of NOS, are present in PF of cardiac patients and their altered levels may contribute to altered cardiac morphology.

Methods

L-Arg and ADMA concentrations in plasma and PF, and echocardiographic parameters of patients undergoing coronary artery bypass graft (CABG, n = 28) or valve replacement (VR, n = 25) were determined.

Results

We have found LV hypertrophy in 35.7% of CABG, and 80% of VR patients. In all groups, plasma and PF L-Arg levels were higher than that of ADMA. Plasma L-Arg level was higher in CABG than VR (75.7±4.6 μmol/L vs. 58.1±4.9 μmol/L, p = 0.011), whereas PF ADMA level was higher in VR than CABG (0.9±0.0 μmol/L vs. 0.7±0.0 μmol/L, p = 0.009). L-Arg/ADMA ratio was lower in the VR than CABG (VRplasma: 76.1±6.6 vs. CABGplasma: 125.4±10.7, p = 0.004; VRPF: 81.7±4.8 vs. CABGPF: 110.4±7.2, p = 0.009). There was a positive correlation between plasma L-Arg and ADMA in CABG (r = 0.539, p = 0.015); and plasma and PF L-Arg in CABG (r = 0.357, p = 0.031); and plasma and PF ADMA in VR (r = 0.529, p = 0.003); and PF L-Arg and ADMA in both CABG and VR (CABG: r = 0.468, p = 0.006; VR: r = 0.371, p = 0.034). The following echocardiographic parameters were higher in VR compared to CABG: interventricular septum (14.7±0.5 mm vs. 11.9±0.4 mm, p = 0.000); posterior wall thickness (12.6±0.3 mm vs. 11.5±0.2 mm, p = 0.000); left ventricular (LV) mass (318.6±23.5 g vs. 234.6±12.3 g, p = 0.007); right ventricular (RV) (33.9±0.9 cm2 vs. 29.7±0.7 cm2, p = 0.004); right atrial (18.6±1.0 cm2 vs. 15.4±0.6 cm2, p = 0.020); left atrial (19.8±1.0 cm2 vs. 16.9±0.6 cm2, p = 0.033) areas. There was a positive correlation between plasma ADMA and RV area (r = 0.453, p = 0.011); PF ADMA and end-diastolic (r = 0.434, p = 0.015) and systolic diameter of LV (r = 0.487, p = 0.007); and negative correlation between PF ADMA and LV ejection fraction (r = -0.445, p = 0.013) in VR.

Conclusion

We suggest that elevated levels of ADMA in the PF of patients indicate upregulated RAS and reduced bioavailability of NO, which can contribute to the development of cardiac hypertrophy and remodeling.  相似文献   

13.
In February 1972 58% of patients euthyroid after iodine-131 therapy given for thyrotoxicosis between 1954 and 1966 had a high plasma TSH (>7·4 μU/ml) and 42% a normal plasma TSH level. A group of 69 of the euthyroid patients with high plasma TSH levels (25·0±2·0 μU/ml) in 1972 were re-examined 15 and 24 months later. The mean plasma TSH in the 66 patients remaining euthyroid at 15 months was 22·6±1·8 μU/ml, while three patients had become hypothyroid. At 24 months 64 of the patients were still available for study, of whom 61 remained euthyroid with a mean plasma TSH of 21·6±2·0 μU/ml, and a further three had become hypothyroid.All of a group of 61 of the euthyroid patients with normal plasma TSH levels (4·0±0·2 μU/ml) in 1972 remained euthyroid at 24 months with a mean plasma TSH of 4·1±0·3 μU/ml, though the plasma TSH level had become slightly raised in three.The mean serum T-4 level in the euthyroid patients with a high plasma TSH was significantly lower, though still in the normal range, than that in the euthyroid patients with a normal plasma TSH both in 1972 and in 1974.Since no patient with a normal plasma TSH level after iodine-131 treatment six to 18 years earlier for thyrotoxicosis developed hypothyroidism over a two-year period, the follow-up of such patients need not be so rigorous as that of similarly treated euthyroid patients with raised plasma TSH levels in whom hypothyroidism developed at the rate of 5% per year.  相似文献   

14.
In this paper, bis (indol-3-yl) methanes (BIMs) were synthesised and evaluated for their inhibitory activity against α-glucosidase and α-amylase. All synthesised compounds showed potential α-glucosidase and α-amylase inhibitory activities. Compounds 5 g (IC50: 7.54 ± 1.10 μM), 5e (IC50: 9.00 ± 0.97 μM), and 5 h (IC50: 9.57 ± 0.62 μM) presented strongest inhibitory activities against α-glucosidase, that were ∼ 30 times stronger than acarbose. Compounds 5 g (IC50: 32.18 ± 1.66 µM), 5 h (IC50: 31.47 ± 1.42 µM), and 5 s (IC50: 30.91 ± 0.86 µM) showed strongest inhibitory activities towards α-amylase, ∼ 2.5 times stronger than acarbose. The mechanisms and docking simulation of the compounds were also studied. Compounds 5 g and 5 h exhibited bifunctional inhibitory activity against these two enzymes. Furthermore, compounds showed no toxicity against 3T3-L1 cells and HepG2 cells.

Highlights

  1. A series of bis (indol-3-yl) methanes (BIMs) were synthesised and evaluated inhibitory activities against α-glucosidase and α-amylase.
  2. Compound 5g exhibited promising activity (IC50 = 7.54 ± 1.10 μM) against α-glucosidase.
  3. Compound 5s exhibited promising activity (IC50 = 30.91 ± 0.86 μM) against α-amylase.
  4. In silico studies were performed to confirm the binding interactions of synthetic compounds with the enzyme active site.
  相似文献   

15.
2-Bromoethanesulfonic acid (BESA) and 2-chloroethanesulfonic acid (CESA) have been reported to be potent inhibitors of methane formation during methanogenic decomposition in batch cultures. However, in a laboratory-scale continuous-flow methanogenic fixed-film column containing a predominance of acetate-decarboxylating methanogens, BESA at 6 × 10−4 M produced only a 41% inhibition of acetate utilization, and CESA at 5.4 × 10−4 M produced a 37% inhibition of acetate utilization. BESA and CESA concentrations were not monitored in the effluent, so their fate is unknown. The organisms in the column were capable of degrading trace halogenated aliphatic compounds (~30 μg/liter) with acetate (100 mg/liter) as the primary substrate. Previous exposure of the cells to halogenated organic compounds may have conferred resistance to BESA and CESA. Degradation of the inhibitor compounds is another possible explanation for the observed effects.  相似文献   

16.
A rapid, selective and sensitive HPLC assay has been developed for the routine analysis of metronidazole in small volumes of rat plasma, gastric aspirate and gastric tissue. The extraction procedure involves liquid–liquid extraction and a protein precipitation step. A microbore Hypersil ODS 3 μm (150×2.1 mm I.D.) column was used with a mobile phase consisting of acetonitrile–aqueous 0.05 M potassium phosphate buffer (pH 7) containing 0.1% triethylamine (10:90). The column temperature was at 25°C and the detection was by UV absorbance at 317 nm. The limit of detection was 0.015 μg ml−1 for gastric juice aspirate and plasma and 0.010 μg g−1 for gastric tissue (equivalent to 0.75 ng on-column). The method was linear up to a concentration of 200 μg ml−1 for plasma and gastric juice aspirate and up to 40 μg g−1 for tissue, with inter- and intra-day relative standard deviations less than 14%. The measured recovery was at least 78% in all sample matrices. The method proved robust and reliable when applied to the measurement of metronidazole in rat plasma, gastric juice aspirate and gastric tissue for pharmacokinetic studies in individual rats.  相似文献   

17.
A sensitive and selective liquid chromatographic assay for determining the non-peptide endothelin A receptor antagonist PD 156707 (I) in rat plasma has been developed and validated. The analyte was isolated from matrix by solid-phase extraction. Liquid chromatographic separation was achieved isocratically ona 3.2 mm I.D., ODS column with a mobile hase of acetonitrile-ammonium phosphate (50 mM, pH 3.5) (44:56, v/v). Column effluent was monitored fluorometrically. Peak-height ratios (analyte/IS) were proportional to I concentrations in rat plasma from 25 to 1000 ng/ml. Assay precision and accuracy for I, based on quality controls, was 9.5% relative standard deviation, with relative error of ±6.5%. The quantitation limit was 25 ng/ml for a 200-μl sample aliquot.  相似文献   

18.
An isocratic high-performance liquid chromatographic method with column switching and direct injection has been developed to determine ciprofloxacin in plasma and Mueller–Hinton broth. An on-line dilution of the sample was performed with a loading mobile phase consisting of 173 mM phosphoric acid. The analyte was retained on a LiChrocart 4-4 precolumn filled with a LiChrospher 100 RP18, 5 μm. An electric-actuated system with two six-port valves allowed a clean-up step with a mixture 20 mM phosphate buffer (pH 3.5)–methanol (97: 3, v/v) and the transfer of the analyte by a back-flush mode to a 150×4.6 mm I.D. column packed with a Kromasil C8 5 μm, using a mobile phase of 20 mM phosphate buffer (pH 3.5)–acetonitrile (85:15, v/v). Fluorescence detection allowed a quantification limit of 0.078 μg/ml with a 40-μl sample size. The method was evaluated to determine its usefulness in studying the pharmacokinetic/pharmacodynamic behaviour of ciprofloxacin in an in vitro model.  相似文献   

19.
A simple liquid chromatography tandem mass spectrometry method was developed and validated according to the guidelines of the US Food and Drug Administration and the European Medicines Agency for a simultaneous quantification of levetiracetam (LEV) and its metabolite, UCB L057 in the plasma of patients. A 0.050 mL plasma sample was prepared by a simple and direct protein precipitation with 0.450 mL acetonitrile (ACN) containing 1 µg/mL of internal standard (IS, diphenhydramine), then vortex mixed and centrifuged. A 0.100 mL of the clear supernatant was diluted with 0.400 mL water and well mixed. A 0.010 mL of the resultant solution was injected into an Agilent Zorbax SB-C18 (2.1 mm×100 mm, 3.5 µm) column with an isocratic elution at 0.5 mL/min using a mixture of 0.1% formic acid in water and ACN (40∶60 v/v). Detection was performed using an AB Sciex API 3000 triple quadrupole mass spectrometer, equipped with a Turbo Ion Spray source, operating in a positive mode: LEV at transition 171.1>154.1, UCB L057 at 172.5>126.1, and IS at 256.3>167.3; with an assay run time of 2 minutes. The lower limit of quantification (LLOQ) for both LEV and UCB L057 was validated at 0.5 µg/mL, while their lower limit of detection (LOD) was 0.25 µg/mL. The calibration curves were linear between 0.5 and 100 µg/mL for both analytes. The inaccuracy and imprecision of both intra-assay and inter-assay were less than 10%. Matrix effects were consistent between sources of plasma and the recoveries of all compounds were between 100% and 110%. Stability was established under various storage and processing conditions. The carryovers from both LEV and UCB L057 were less than 6% of the LLOQ and 0.13% of the IS. This assay method has been successfully applied to a population pharmacokinetic study of LEV in patients with epilepsy.  相似文献   

20.

Background

Increased endocannabinoid tonus by dual-action fatty acid amide hydrolase (FAAH) and substrate selective cyclooxygenase (COX-2) inhibitors is a promising approach for pain-relief. One such compound with this profile is 2-(2-fluorobiphenyl-4-yl)-N-(3-methylpyridin-2-yl)propanamide (Flu-AM1). These activities are shown by Flu-AM1 racemate, but it is not known whether its two single enantiomers behave differently, as is the case towards COX-2 for the parent flurbiprofen enantiomers. Further, the effects of the compound upon COX-2-derived lipids in intact cells are not known.

Methodology/Principal Findings

COX inhibition was determined using an oxygraphic method with arachidonic acid and 2-arachidonoylglycerol (2-AG) as substrates. FAAH was assayed in mouse brain homogenates using anandamide (AEA) as substrate. Lipidomic analysis was conducted in unstimulated and lipopolysaccharide + interferon γ- stimulated RAW 264.7 macrophage cells. Both enantiomers inhibited COX-2 in a substrate-selective and time-dependent manner, with IC50 values in the absence of a preincubation phase of: (R)-Flu-AM1, COX-1 (arachidonic acid) 6 μM; COX-2 (arachidonic acid) 20 μM; COX-2 (2-AG) 1 μM; (S)-Flu-AM1, COX-1 (arachidonic acid) 3 μM; COX-2 (arachidonic acid) 10 μM; COX-2 (2-AG) 0.7 μM. The compounds showed no enantiomeric selectivity in their FAAH inhibitory properties. (R)-Flu-AM1 (10 μM) greatly inhibited the production of prostaglandin D2 and E2 in both unstimulated and lipopolysaccharide + interferon γ- stimulated RAW 264.7 macrophage cells. Levels of 2-AG were not affected either by (R)-Flu-AM1 or by 10 μM flurbiprofen, either alone or in combination with the FAAH inhibitor URB597 (1 μM).

Conclusions/Significance

Both enantiomers of Flu-AM1 are more potent inhibitors of 2-AG compared to arachidonic acid oxygenation by COX-2. Inhibition of COX in lipopolysaccharide + interferon γ- stimulated RAW 264.7 cells is insufficient to affect 2-AG levels despite the large induction of COX-2 produced by this treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号