首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The conditions of the enzyme immunoassay for the detection of Brucella antigens have been selected, making it possible to detect these antigens both in solutions and in biological material within 3-4 hours. In guinea pigs infected with B. abortus 99 in a dose of 1,000 microbial cells, brucellar antigen has been detectable in the organs and blood serum of the animals as early as 24 hours after infection. This assay, if carried out under the optimal conditions, detects soluble brucellar polysaccharide antigen at a concentration of 1 ng/ml and Brucellae at a concentration of 5 X 10(4) microbial cells/ml in the presence of 200-fold surplus of other bacterial cells.  相似文献   

2.
Materials on the development of an enzyme immunoassay (EIA) system for the detection of the antigens of C. burnetii, the causative agent of Q rickettsiosis, are presented. The system is highly specific and effective with respect to both corpuscular antigens of phases 1 and 2 and soluble antigen (lipopolysaccharide). The sensitivity of this method varies within the range 5-100 ng/ml. The effectiveness of EIA as a quantitative (semiquantitative) control test used in the process of the production of Coxiella preparations has been demonstrated.  相似文献   

3.
Dot immunoassay was developed to improve the quality of laboratory diagnosis of brucellosis. Particles of colloid gold were used as a marker of specific antibodies. The method was used for detecting Brucella antigens in artificially contaminated environmental objects (soil and water) and in biological material (milk, blood serum, and visceral homogenates of animals). The sensitivity of the test system was 19.5.10(3)-62.5.10(4) CFU/ml. Specificity of the assay was tested with 10 heterologous antigenically closely related bacterial species. The proposed test system is simple, economic, highly sensitive and specific, and requires no expensive equipment and reagents.  相似文献   

4.
An enzyme immunoassay (EIA) system for the detection of fodder yeast antigens in the air of production areas at fodder protein producing plants has been developed. The method has proved to be highly sensitive and specific and shows advantages in comparison with the nonspecific method of low sensitivity, currently used at such plants. The sensitivity of solid-phase EIA techniques is 0.001 micrograms/ml (for protein) or 10(2)-10(3) cells/ml, and 10 ng/ml for soluble antigen. No cross reactions with bakers' yeast antigen have been observed.  相似文献   

5.
Mice monoclonal antibodies against lypopolysaccharides (LPS) of Brucella abortus has been obtained and characterized. The antibodies detected LPS of B. abortus, B. melitensis and B. suis with high sensivity and specificity and did not react with LPS of Yersinia enterocolitica O:3, Y. enterocolitica O:9, Salmonella typhimurium, and Francisella tularensis. It has been shown that interaction of monoclonal antibodies and LPS of Brucella species can be critically dependent from buffer system. Obtained monoclonal antibodies allowed to develop highly sensitive assay which was able to detect antigens of Brucella species in concentrations 0.05 - 0.1 ng/ml. The assay can be used for detection and identification of Brucella species.  相似文献   

6.
Monoclonal antibodies (McAb) 2AH10, specifically reacting with protein preparations having mol. wt. of 18 and 38 kD and not interacting with brucellar lipopolysaccharide (LPS) and protein-polysaccharide antigen, have been obtained. As shown with the use of McAb 2AH10, Brucella spp. and Yersinia enterocolitica O:9 possess common antigenic determinants, localized not only in the area of their LPS, which is generally known, but also in the area of their outer cell-wall proteins with mol. wt. 18 and 38 kD. The sensitivity of the solid-phase enzyme immunoassay and the latex agglutination test with the use of McAb 2AH10 is essentially higher in the detection of B. abortus and B. suis, than B. melitensis and B. rangiferi, as well as Y. enterocolitica O:9. Essential differences observed in the detected concentrations of different Brucella species and Y. enterocolitica O:9 are seemingly linked with different expression of specific antigenic determinants, detected with the use of McAb 2AH10 in the corpuscular antigens under study.  相似文献   

7.
Experiments were conducted on guinea pigs sensitized by the delayed and immediate types of allergy. Different antigens obtained from the strain of Brucella abortus BA-19 were used for sensitization and the resolving action. Comparison of the resolving properties of the corpuscular, soluble (ultrasound treated) antigens and purified protein fractions, polysaccharide and RNA was carried out in the skin reactions of the immediate and delayed type, passive skin anaphylaxis, acute anaphylactic shock, and the Schults-Dale test. Immediate reactions to the purified protein fraction were weaker than those to the whole soluble antigen, by which the animals were sensitized. Polysaccharide and the RNA-fractions proved to be inactive in the allergic reactions.  相似文献   

8.
The 16S-23S rRNA spacer regions of Brucella abortus, B. melitensis, and B. suis were cloned and subcloned after PCR amplification. Sequence analysis of the inserts revealed a spacer of about 800 bp with very high ( > 99%) homology among the three species examined. Two genus-specific primer pairs, BRU-P5-BRU-P8 and BRU-P6-BRU-P7, that could be used in a nested PCR format and three genus-specific DNA probes, BRU-ICG2, BRU-ICG3, and BRU-ICG4, were deduced from this spacer. The specificity and sensitivity of both primer sets and probes were examined by testing them against a collection of 18 Brucella strains and 56 strains from other relevant taxa by using PCR and the Line Probe Assay (LiPA), respectively. A method for direct detection of Brucella spp. in 1 ml of raw milk was developed on the basis of enzymatic treatment of the milk components and subsequent PCR and LiPA hybridization. After a single PCR, sensitivities of 2.8 x 10(5) and 2.8 x 10(4) CFU/ml were obtained for detection by agarose gel electrophoresis and LiPA, respectively. Nested PCR yielded a sensitivity of 2.8 x 10(2) CFU/ml for both methods.  相似文献   

9.
In a biomass assay based on adenosine 5(')-triphosphate (ATP) bioluminescence, extracellular ATP is removed; then intracellular ATP is extracted from the microorganism by an ATP extractant and subsequently reacted with luciferase. To provide a highly sensitive assay, the concentration of benzalkonium chloride (BAC) in the ATP extractant was optimized by using a mutant luciferase resistant to BAC. The use of 0.2% BAC, which was acceptable for the luciferase, simultaneously achieved the maximum extraction of intracellular ATP from microorganisms and the inactivation of the ATP-eliminating enzymes for removal of extracellular ATP. The detection limit (blank+3 SD) for ATP was 1.8x10(-14)M (1.8x10(-18)mol/assay) in the presence of the ATP extractant with coefficients of variation of 0.7 to 6.3%. The reagent system coupled with the ATP-eliminating enzymes allowed for the detection of 93 colony-forming units (CFU)/ml of Escherichia coli ATCC 25922, 170CFU/ml of Pseudomonas aeruginosa ATCC 27853, 170CFU/ml of Proteus mirabilis ATCC 29906, 68CFU/ml of Staphylococcus aureus ATCC 25923, and 7.7CFU/ml of Bacillus subtilis ATCC 6051. The yeast cell of Saccharomyces cerevisiae IFO 10217 could be detected at 1CFU/ml. With 54 kinds of microorganisms, the average ATP extraction efficiency compared to the trichloroacetic acid extraction method was 81.0% in 24 strains among gram-negative bacteria, 99.4% in 13 strains among gram-positive bacteria, and 97.0% in 17 strains among yeast. The ATP contents of the gram-negative bacteria, gram-positive bacteria, and yeasts ranged from 0.40 to 2.70x10(-18)mol/CFU (mean=1.5x10(-18)mol/CFU), from 0.41 to 16.7x10(-18)mol/CFU (mean=5.5x10(-18)mol/CFU), and from 0.714 to 54.6x10(-16)mol/CFU (mean=8.00x10(-16)mol/CFU), respectively.  相似文献   

10.
High sensitivity immunoassays using particulate fluorescent labels.   总被引:7,自引:0,他引:7  
The use of polystyrene fluorescent microspheres as sensitive labels in direct-detection (not enzymatically amplified) heterogeneous equilibrium "sandwich" immunoassays in 96-well plates is described. With mouse IgG as a model antigen, a fluorescent particulate label is more sensitive than a corresponding soluble reporter. The limit of detection of mouse IgG in the multiparametrically optimized assay was 0.2 ng/ml (7.6 x 10(8) antigens/ml) for the particulate reporter and 50 ng/ml (1.9 x 10(11) antigens/ml) for the soluble reporter. The sensitivities of assays using the particulate label were dependent on the surface densities of the capture and reporter antibodies and the concentration of reporter beads. Sensitivity was improved by adding the preformed reporter antibody/fluorescent microsphere complex to trapped antigen on the well surfaces instead of sequentially adding the reporter antibody and then the fluorescent microspheres. Maximal (equilibrium) binding of the particulate reporter to captured antigen occurred after 20 h with a concentration of 1.4 x 10(9) reporter beads/ml. Thus, particulate fluorescent labels provide high sensitivity in direct-detection immunoassays.  相似文献   

11.
Technique for immobilization using sodium alginate as the matrix to preserve Bacillus thuringiensis var. israelensis isolates for long time storage was developed. Two strains of B. thuringiensis var. israelensis viz., VCRC B-17 and WHO standard strain IPS-82 were immobilized in alginate matrix and preserved at 4 degrees C and when tested both were found to have maintained excellent viability and mosquito larvicidal activity for 10 years. Mosquito larvicidal activity of B-17 and IPS-82 alginate beads, in term of LC(50) values before storage was 72.07 ng/ml and 47.07 ng/ml, respectively and after storage at 4 degrees C for a period of 1 to 10 years the values ranged from 69.88 to 73.86 ng/ml with a mean of 72.38 ng/ml and 45.32 to 48.60 ng/ml with a mean of 47.49 ng/ml, respectively. Similarly spore count of the beads of the respective strains was 4.37 x 10(8) and 3.33 x 10(10) CFU/mg before storage. After storage at 4 degrees C for a period of 1 to 10 years the counts of the beads of the respective strains ranged from 4.23 x 10(8) to 4.83 x 10(8) CFU/mg (mean of 4.49 x 10(8) CFU/mg) and 3.2 x 10(10) to 3.87 x 10(10) CFU/mg (mean of 3.54 x 10(10) CFU/mg). The alginate matrix immobilization technique has many advantages over free cells are that they enhance the stability of both spores and toxin against several physicochemical conditions and confer reduced susceptibility to contamination.  相似文献   

12.
We report an electro-mechanical biosensor for electrical detection of proteins with disease markers using self-sensing piezoresistive micro-cantilevers. Electrical detection, via surface stress changes, of antigen-antibody (Ag-Ab) specific binding was accomplished through a direct nano-mechanical response of micro-fabricated self-sensing micro-cantilevers. A piezoresistive sensor measures the film resistance variation with respect to surface stress caused by biomolecules specific binding. When specific binding occurred on a functionalized Au surface, surface stress was induced throughout the cantilever, resulting in cantilever bending and resistance change of the piezoresistive layer. The cantilever biosensors were used for the detection of prostate specific antigen (PSA) and C-reactive proteins (CRP), which are a specific marker of prostate cancer and cardiac disease. From the above experiment, it was revealed that the sensor output voltage was proportional to the injected antigen concentration (without antigen, 10 ng/ml, 100 ng/ml, 1 microg/ml). PSA and CRP antibodies were found to be very specific for their antigens, respectively. This indicated that the self-sensing micro-cantilever approach is beneficial for detecting disease markers, and our piezoresistive micro-cantilever sensor system is applicable to miniaturized biosensor systems.  相似文献   

13.
The solid-phase technique for the detection of antibodies and antigens has been developed and named the bacteriosorption test. The test is based on binding staphylococci containing protein A with the Fc-regions of IgG-antibodies attached to antigens immobilized on polystyrene. The possibilities of this technique have been analyzed with the use of diphtheria toxoid, house-dust allergen and homologous rabbit antisera. In the detection of antibodies the proposed test is not inferior to the passive hemagglutination test, and its sensitivity in the detection of antigens by the sandwich technique reaches 0.05-0.1 micrograms/ml. The specificity of the technique has been experimentally confirmed by the inhibition of the reaction with soluble antigen and staphylococcal protein A. The variability factor of the technique does not exceed 10%.  相似文献   

14.
A PCR-based detection system specific for Lactobacillus paracasei LTH 2579 was developed and applied to follow the fate of the strain in complex ecosystems. This strain was isolated from fruit mash and was characterised as being highly resistant to low pH and bile at concentrations as they occur in the human digestive tract. The application of the subtraction hybridisation technique permitted to identify a 235 bp chromosomal DNA fragment of strain LTH 2579. Based on this target sequence a specific PCR system was developed and combined with the species-specific PCR system for L. paracasei. This combination of PCR based detection systems was successfully applied to monitor L. paracasei LTH 2579 in fermented sausages which were inoculated with this strain (2.0 x 10(7) CFU/g) together with the strongly competitive L. sakei LTH 681 (1.0 x 10(6) CFU/g). At the time of consumption of the sausages the respective counts were 1.8 x 10(7) and 1.4 x 10(8) CFU/g. After consumption of the sausages by three volunteers L. paracasei LTH 2579 was recovered from fecal samples. The counts determined for the strain ranged between 1.2 x 10(7) and 1.5 x 10(8) CFU/g of feces. The fortuitous lactobacilli constituted a share of 5-12% of the lactobacilli in the fecal flora.  相似文献   

15.
An inhibition enzyme-linked immunosorbent assay (IELISA) was used to detect the presence of schistosome antigens obtained from cercariae, adult worms, and eggs of the parasite. Using appropriate titers of Schistosoma mansoni infected mouse serum (IMS), it was possible to detect less than 10 ng/ml of schistosome antigen when added to phosphate-buffered saline (PBS, pH 7.2) or normal human serum (NHS). The sensitivity of the test was highly contingent on the number of experimental variables including antibody titer and antigenic source. The results of specificity studies were complicated. Although there was no cross-reactivity detected with other unrelated antigen preparations, extensive cross-reactivity between various schistosome species and "stage-specific" antigens was observed. The IELISA, utilizing IMS, can quantitate the degree of antigenic cross-reactivity, i.e., genus-specific and cross-reacting antigenic determinants. Soluble egg antigen (SEA) preparations obtained from S. mansoni and S. japonicum actually "cross-reacted" more than cercarial- and egg-derived antigens obtained from the same species (S. mansoni). This test also showed a 32-fold increase in specificity for the quantitative detection of specific antigenic determinants when monoclonal antibodies were used to restrict the heterogeneity of the measured response. The technique proved satisfactory for the quantification of parasitic burden in mice and the detection of active infections in humans. Circulating antigen disappeared with a t 1/2 of 72-96 hr after successful treatment.  相似文献   

16.
Approaches to obtaining stable mouse hybridomas synthesizing monoclonal antibodies (McAb) to M. hominis key antigens were developed. 4 clones capable of the stable synthesis of McAb of different IgG classes were obtained. Clones A3/2 and A5/D produced antibodies to the thermostable determinant to with a mol. wt. of 80-120 kD, sensitive to sodium periodate and resistant to potassium proteinase. Clone H9/B2 synthesized McAb which interacted with potassium proteinase-sensitive M. hominis thermolabile determinant with a mol. wt. of 80 kD. McAb of clone A3/2, labeled with fluorescein isothiocyanate and horse-radish peroxidase, specifically reacted with M. hominis antigens in the immunofluorescence test and the immunoenzyme assay (EIA). The sensitivity of EIA was 0.25 ng/ml of antigen protein. These data may serve as prerequisites for the development of diagnostic test systems aimed at the detection of M. hominis antigens in different clinical substances.  相似文献   

17.
The variant of enzyme-linked immunosorbent assay (ELISA) for detection of Mycoplasma pneumoniae (Mp) antigens in sera of patients with respiratory infections was developed. Sensitivity of detection of soluble antigens of Mp in modeling experiment varied from 1.5 to 1.0 ng/ml (on protein). Approbation of the assay was performed using 50 serum samples obtained from patients with confirmed diagnosis of respiratory mycoplasmosis. In the ELISA test Mp antigens were detected in 96% of samples. Obtained results were confirmed by testing of these serum samples and isolated from them circulating immune complexes (CICs) in immunoblotting using polyclonal antibodies labeled by horse-radish peroxidase. Mp antigenswere detected both in free state and as components of CICs. Specific reaction was observed with proteins, which molecular mass varied from 30 to 170 kDa (30, 37, 45, 56, 58, 72, 90, 130 and 170 (160) kDa). Obtained results point to appropriateness of use of developed assay for detection Mp antigens in sera of patients with respiratory infections.  相似文献   

18.
A surface plasmon resonance biosensor (Biacore) was used to detect Salmonella through antibodies reacting with Salmonella group A, B, D and E (Kauffmann-White typing). In the assay designed, anti-Salmonella antibodies immobilized to the biosensor surface were allowed to bind injected bacteria followed by a pulse with soluble anti-Salmonella immunoglobulins to intensify the signal. No significant interference was found for (mixtures of) 30 non-Salmonella serovars at 10(9) CFU ml(-1). A total of 53 Salmonella serovars were successfully detected at 1 x 10(7) CFU ml(-1), except those of groups C, G, L and P, as expected. The cut-off point was determined with an equicellular mixture of Salmonella enteritidis and Salmonella typhimurium at a final amount of 1.7 x 10(3) CFU per test portion. Although further work is needed to cover the detection of all relevant Salmonella serovars in food-producing animals and food products, this work demonstrates the merits of this alternative biosensor approach in terms of automation, sensitivity, specificity, simple handling and limited hands-on time.  相似文献   

19.
Monoclonal antibodies (MAbs) against Vibrio vulnificus (isolate I, VVC and isolate II, VVB) were raised using heat-killed and heat-killed plus SDS-mercaptoethanol treated forms of VVC and VVB for immunizing Swiss mice. Twenty three hybridomas producing MAbs against V. vulnificus were selected and divided into five groups according to their specificities to different V. vulnificus isolates and apparent protein antigens which ranged from approximately 3-50 kDa. Four groups were specific to V. vulnificus without cross reactivity to either other Vibrio spp. or other bacterial species. In dot blot based assays, one group of MAbs were specific to VVC, with a sensitivity of approximately 1.6 x 10(7) CFU ml(-1) (approximately 1.6 x 10(4) cells spot(-1)), and bound to proteins of approximately 50 and approximately 39 kDa. Other MAbs, binding to proteins ranging from approximately 3-14 and approximately 40 kDa, detected VVB (but not VVC) with high sensitivity at approximately 1.6 x 10(5) and 4 x 10(6) CFU ml(-1) (approximately 1.6 x 10(2) and 4 x 10(3) cells spot(-1)), respectively. In addition, certain MAbs were able to recognize V. vulnificus in tissues by means of immunohistochemistry. The remaining groups demonstrated cross reactivity to Vibrio fluvialis. MAbs from this study can, therefore, detect the difference between some isolates of V. vulnificus and in addition to pathogen detection may, with further antibodies, form the basis of serovar typing isolates in the future.  相似文献   

20.
Approaches to obtaining stable mouse hybridomas, capable of producing monoclonal antibodies (McAb) to M. pneumoniae key antigens, were developed. As the result of hybridization experiments, 7 clones were obtained; of these, 4 clones stably synthesized IgG McAb. Clones H1/H9 and H9/B2 synthesized antibodies to thermolabile, proteinase-sensitive K protein, produced by cytoplasmic membranes of M. pneumoniae cells. The molecular weight of this protein was found to be 90 kD. McAb of clone H1/H9, labeled with horse-radish peroxidase and fluorescein isothiocyanate, specifically reacted with M. pneumoniae antigens in the immunofluorescence test and the enzyme immunoassay (EIA). The sensitivity of EIA was 0.25 ng/ml of antigen protein. These data are prerequisites for the development of diagnostic test systems for the detection of M. pneumoniae antigens in different biological substances obtained from patients with respiratory pathology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号