首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Measurement of cellular DNA content and the analysis of the cell cycle can be performed by flow cytometry. Protocols for DNA measurement have been developed including Bivariate cytokeratin/DNA analysis, Bivariate BrdU/DNA analysis, and multiparameter flow cytometry measurement of cellular DNA content. This review summarises the methods for measurement of cellular DNA and analysis of the cell cycle and discusses the commercial software available for these purposes.  相似文献   

2.
3.
Widrow RJ  Laird CD 《Cytometry》2000,39(2):126-130
BACKGROUND: One of the most dramatic events during the course of the mammalian cell cycle is mitosis, when chromosomes condense and segregate, the nuclear envelope breaks down, and the cell divides into two daughter cells. Although cells undergoing mitosis are cytologically distinguishable from nonmitotic cells, few molecular markers are available to specifically identify mitotic cells, especially cells within different stages of mitosis. METHODS: We applied the flow cytometric method of Juan et al. (Cytometry 32:71-77, 1998) to obtain cells with various levels of the molecular markers cyclin B1 and phosphorylated histone H3; fluorescence microscopy was then used to identify sorted cells in different stages of mitosis. RESULTS: We observed the substantial enrichment of submitotic cell populations. CONCLUSIONS: This method represents an effective approach to obtain an enriched population of submitotic cells without the use of drug treatments or prior synchronization.  相似文献   

4.
Summary The interactions and binding characteristics of DNA dyes used in the flow cytometric analysis of chromatin were studied using human chromosomes and mouse thymocyte nuclei. The kinetics of dye binding and the relationship between fluorescence intensity and dye concentration are presented. Under the conditions used, Hoechst 33258, propidium iodide and chromomycin A3 reach an equilibrium with thymocyte nuclei after approximately 5 min, 20 min and more than 1 h, respectively. The same binding kinetics are observed with Hoechst 33258 and chromomycin when nuclei are stained with a mixture of the two dyes. Sodium citrate, which improves the resolution of flow karyotypes, causes a rapid increase in Hoechst and propidium iodide fluorescence, but a decrease in the fluorescence of chromomycin. The relative peak positions of chromosomes in a flow karyotype are unaffected by sodium citrate addition. The spectral interaction between Hoechst and chromomycin is quantified. There is variation among the human chromosome types in the amount of energy transferred from Hoechst to chromomycin. By measuring the Hoechst and chromomycin fluorescence of each chromosome after Hoechst excitation, it is shown that the amount of energy transferred is correlated to the ratio of the amount of Hoechst to chromomycin bound. Although the energy transfer between the two dyes is considerable, this has little effect on the reproducibility of flow karyotype measurements. The relative peak positions of all human chromosomes in a 64×64 channel flow karyotype, except for the 13 and Y chromosomes, vary in the order of 0.5 channel over a 16-fold change in either Hoechst or chromomycin concentration. This implies that, with the present flow cytometers, variation in staining conditions will have minimal effects on the reproducibility of the relative peak positions in flow karyotypes.In honour of Prof. P. van Duijn  相似文献   

5.
The interactions and binding characteristics of DNA dyes used in the flow cytometric analysis of chromatin were studied using human chromosomes and mouse thymocyte nuclei. The kinetics of dye binding and the relationship between fluorescence intensity and dye concentration are presented. Under the conditions used, Hoechst 33258, propidium iodide and chromomycin A3 reach an equilibrium with thymocyte nuclei after approximately 5 min, 20 min and more than 1 h, respectively. The same binding kinetics are observed with Hoechst 33258 and chromomycin when nuclei are stained with a mixture of the two dyes. Sodium citrate, which improves the resolution of flow karyotypes, causes a rapid increase in Hoechst and propidium iodide fluorescence, but a decrease in the fluorescence of chromomycin. The relative peak positions of chromosomes in a flow karyotype are unaffected by sodium citrate addition. The spectral interaction between Hoechst and chromomycin is quantified. There is variation among the human chromosome types in the amount of energy transferred from Hoechst to chromomycin. By measuring the Hoechst and chromomycin fluorescence of each chromosome after Hoechst excitation, it is shown that the amount of energy transferred is correlated to the ratio of the amount of Hoechst to chromomycin bound. Although the energy transfer between the two dyes is considerable, this has little effect on the reproducibility of flow karyotype measurements. The relative peak positions of all human chromosomes in a 64 X 64 channel flow karyotype, except for the 13 and Y chromosomes, vary in the order of 0.5 channel over a 16-fold change in either Hoechst or chromomycin concentration.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
New staining methods and automated instruments are now available to evaluate the sperm cell in vitro. Individual compartments of the sperm cell, such as the nucleus and the plasma and acrosomal membranes, may be investigated, as well as the cell function as shown by mitochondria activity and capacitation. Various probes are used and they can be analyzed by direct light or fluorescent microscopy or by flow cytometry. The automated instruments allow objective and accurate analysis and quantification as well as the ability to evaluate large population of cells in a shorter time, thus providing accurate evaluation of sperm quality. However, before these test can be recommended for routine clinical and investigational use, in the stallion, they need to be confirmed on a larger number of stallions and their correlation with traditional semen parameters and with stallion fertility has to be demonstrated.  相似文献   

7.
DNA content analysis of insect cell lines by flow cytometry   总被引:1,自引:0,他引:1  
The DNA content of insect cell lines (6 lepidoptera, 1 coleoptera and 1 diptera) was determined by flow cytometry. The DNA profiles of the 8 cell lines tested were different. They were characterized by the presence of several peaks (2 to 7) corresponding to different ploidy levels, by differences in the fluorescence intensity of each peak and by the proportion of cells in each peak. Two cell lines (Cf124 and BmN) were constituted of 2 distinct populations of cells. The DNA profiles of the cell lines were stable among the passages and during the length of time culture. This technique was demonstrated to be useful for the detection of mixed cell lines and nucleopolyhedrovirus cell infection, using Autographa californica MNPV. The flow cytometry gives interesting results on the cell cycle and the ploidy level; it appears as a good tool for insect cell lines characterization. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

8.
The measurement of color development with time in cells following the start of a staining reaction is of interest in a number of biological systems. These include the subsets of peripheral white blood cells after acridine orange staining, the uptake by cells and nuclei of fluorescent agents, especially antitumor drugs, and measurement of intracellular enzyme kinetics using fluorogenic or absorbing substrates. The present work describes a simple computer program for analyzing flow cytometric (FCM) data versus time, including both the population kinetics of color development and the variability of staining speed within one population of cells. A single-channel absorption measurement in flow (Technicon Hemalog D) was used to record peroxidase kinetics in peripheral blood cells. Every 5 s, a 64-channel absorption histogram was recorded, up to a maximum of 64 histograms. The data were then analyzed by a computer program which searched for the peak channel of each histogram. A least-squares fit was computed for these maxima. The asymmetries of the 64 absorption histograms were compared to see if there was more than one population present with different time constants. Although developed for enzyme kinetic measurements, this program may have wider usefulness in any measurements of time-dependent phenomena by FCM.  相似文献   

9.
INTRODUCTION: Violet laser diodes have become common and reliable laser sources for benchtop flow cytometers. While these lasers are very useful for a variety of violet and some ultraviolet-excited fluorochromes (e.g., DAPI), they do not efficiently excite most UV-stimulated probes. In this study, the next generation of InGaN near-UV laser diodes (NUVLDs) emitting in the 370-375-nm range have been evaluated as laser sources for cuvette-based flow cytometers. METHODS: Several NUVLDs, ranging in wavelength from 370 to 374 nm and in power level from 1.5 to 10 mW, were mounted on a BD Biosciences LSR II and evaluated for their ability to excite cells labeled with the UV DNA binding dye DAPI, several UV phenotyping fluorochromes (including Alexa Fluor 350, Marina Blue, and quantum dots), and the fluorescent calcium chelator indo-1. RESULTS: NUVLDs at the 8-10-mW power range gave detection sensitivity levels comparable to more powerful solid-state and ion laser sources, using low-fluorescence microsphere beads as measurement standards. NUVLDs at all tested power levels allowed extremely high-resolution DAPI cell cycle analysis, and sources in the 8-10-mW power range excited Alexa Fluor 350, Marina Blue, and a variety of quantum dots at virtually the same signal-to-noise ratios as more powerful UV sources. CONCLUSIONS: These evaluations indicate that near-UV laser diodes installed on a cuvette-based flow cytometer performed nearly as well as more powerful solid-state UV lasers on the same instrumentation, and comparably to more powerful ion lasers on a jet-in-air system, and. Despite their limited power, integration of these small and inexpensive lasers into benchtop flow cytometers should allow the use of flow cytometric applications requiring UV excitation on a wide variety of instruments.  相似文献   

10.
BACKGROUND: Slide-based cytometry is a key technology for polychromatic cytomic investigations. Here we exploit the relocalization and merge feature of Laser Scanning Cytometry for distinguishing fluorochromes of comparable emission spectra but different photostabilities. METHODS: Blood specimens were stained with the fluorochrome pairs: FITC/ALEXA488, PE/ALEXA532, or APC/ALEXA633. Bleaching was performed by repeated laser excitation. RESULTS: Since ALEXA dyes are photostable as compared to the conventional fluorochromes FITC, PE, and APC, a differentiation within one fluorochrome pair is possible. CONCLUSION: The sequential photobleaching method results in an increased information density on a single cell level and represents an important component to perform polychromatic cytometry.  相似文献   

11.
12.
BACKGROUND: Current methods for multiparameter DNA flow cytometry suffer from several limitations. These include significant modifications of cell morphological parameters, the impossibility to counterstain cells with certain fluorochromes, and laborious tuning of the instrument that, for some procedures, must be equipped with an ultraviolet (UV) laser. To overcome these problems, we developed a novel method for the simultaneous analysis of morphological parameters, four-color immunophenotyping, and stoichiometric DNA labeling using a bench-top flow cytometer. METHODS: The method consists of a mild permeabilization/fixation treatment at room temperature, followed by labeling with fluorochrome-conjugated monoclonal antibodies (mAbs) and with the DNA dye 7-aminoactinomycin D (7-AAD) at 56 degrees C. RESULTS: Using this method, we analyzed resting peripheral blood mononucleated cells (PBMC), proliferating T cells cultured in the presence of interleukin-2 (IL-2), and lymphoblastoid B cells. Lymphocytes, monocytes, and lymphoblasts treated by this procedure retained differential light scattering (DLS) characteristics virtually identical to those of untreated cells. This allowed regions to be drawn on forward scatter (FSC) and side scatter (SSC) cytograms resolving different cell populations. DLS were preserved well enough to distinguish large lymphoblasts in the S or G2/M phases from small G0/G1 cells. Also, stainability with fluorescein-isothiocyanate (FITC), R-phycoerythrin (PE), allophycocyanin (APC)-conjugated mAbs was generally preserved. DNA labeling with 7-AAD was of quality good enough to permit accurate cell cycle analysis. CONCLUSIONS: The method described here, which we called integral hot staining (IHS), represents a very simple, reproducible, and conservative assay for multiparameter DNA analysis using a bench-top flow cytometer. Last but not least, the cytometer tuning for multiparameter acquisition is straightforward.  相似文献   

13.
DNA index (DI) measurements and chromosomal analysis of 42 transitional cell carcinomas were done after mechanical and enzymatical disaggregation of the tumor specimens. The results obtained with these different disaggregation techniques were compared in the 33 cases (79%) that showed recognizable chromosomes. The enzymatically obtained cell suspensions could not be used for chromosomal analysis after short-term culture of 24 hours. In four cases, the DI after enzymatical treatment could not be estimated. In most cases, the DI obtained from the tumor cells was similar for both aggregation techniques, with the exception of four cases of enzymatically treated cell suspensions in which the DI could not be estimated. The average DI of the aneuploid tumors was 13% higher than the corresponding chromosome count. In 19% of the aneuploid tumors the proportion of aneuploid cells could not be measured after enzymatical treatment. In the remaining suspensions the proportion of diploid cells was higher after enzymatical disaggregation than after mechanical treatment. It is concluded that for flow cytometric and direct chromosomal analysis of bladder tumors, the mechanical disaggregation technique is most suitable.  相似文献   

14.
15.
A new triple fluorescent staining method was developed to evaluate frozen-thawed dog spermatozoa. This method was used to compare functional parameters of canine spermatozoa cryopreserved using 2 different freezing-thawing protocols. One ejaculate from each of 10 dogs was split into 2 aliquots and processed using the Andersen method or the CLONE method. Semen samples were evaluated immediately after thawing and after 3 h of incubation at 37 degrees C. Plasma membrane integrity and acrosomal status of the spermatozoa were evaluated simultaneously by flow cytometry using a combination of 3 fluorescent dyes: Carboxy-SNARF-1 (SNARF), to identify the live spermatozoa; propidium iodide (PI), which only stains dead cells or cells with damaged membranes; and fluorescein isothiocyanate (FITC)-conjugated Pisum sativum agglutinin (PSA), which binds to the acrosomal content of spermatozoa with damaged plasma and outer acrosomal membranes. The accuracy of this new staining method in quantifying the proportions of live and dead spermatozoa by flow cytometry was evaluated by comparing it with the staining technique using carboxyfluorescein diacetate and propidium iodide (CFDA-PI), which yielded high correlation coefficients. The triple-stained sperm samples were also analyzed by epifluorescence microscopy, and both methods proved to be highly correlated. Post-thaw progressive motility and plasma membrane integrity were similar for the 2 freezing procedures, but the proportion of damaged acrosomes after thawing was lower using the Andersen method and the spermatozoa had a higher thermoresistance. This new triple staining method for assessing canine sperm viability and acrosomal integrity provides an efficient procedure for evaluating frozen-thawed dog semen samples either by flow cytometry or fluorescence microscopy.  相似文献   

16.
BACKGROUND: The ability of the comet assay to quantify DNA strand breaks and alkali labile sites has been widely demonstrated. In this study, this assay was tested for its ability to identify DNA fragmentation occurring during apoptosis in comparison with standard DNA flow cytometry analysis. METHODS: Staurosporine-induced apoptosis in CHO cells is an adequate model to study a rapid time- and dose-dependent appearance of this process. RESULTS: Nuclear staining with DAPI confirmed the induction of apoptosis with a typical chromatin condensation and fragmentation. Analysis of propidium-iodide- (PI) stained DNA by flow cytometry showed the presence of a pre-G1 peak, characteristic of apoptotic cells, 6 h after drug treatment. The detection of highly damaged cells (HDC) by the comet assay after 3 h treatment occurred earlier than the detection of apoptotic cells by flow cytometry. However, HDC were missed when the DNA fragmentation was too high, preventing accurate quantification of late apoptotic cells. CONCLUSIONS: The comet assay is more sensitive than standard DNA flow cytometry to detect early DNA fragmentation events occurring during apoptosis. However, the comet assay modified by omitting electrophoresis was necessary to quantify apoptotic fraction at later stages.  相似文献   

17.
Traditionally, many cell-based assays that analyze cell populations and functionalities have been performed using flow cytometry. However, flow cytometers remain relatively expensive and require highly trained operators for routine maintenance and data analysis. Recently, an image cytometry system has been developed by Nexcelom Bioscience (Lawrence, MA, USA) for automated cell concentration and viability measurement using bright-field and fluorescent imaging methods. Image cytometry is analogous to flow cytometry in that gating operations can be performed on the cell population based on size and fluorescent intensity. In addition, the image cytometer is capable of capturing bright-field and fluorescent images, allowing for the measurement of cellular size and fluorescence intensity data. In this study, we labeled a population of cells with an enzymatic vitality stain (calcein-AM) and a cell viability dye (propidium iodide) and compared the data generated by flow and image cytometry. We report that measuring vitality and viability using the image cytometer is as effective as flow cytometric assays and allows for visual confirmation of the sample to exclude cellular debris. Image cytometry offers a direct method for performing fluorescent cell-based assays but also may be used as a complementary tool to flow cytometers for aiding the analysis of more complex samples.  相似文献   

18.
Sixteen ear malignant melanomas (MM) were studied for ploidy and cell cycle analysis by flow and image cytometry. The results were compared with clinical (age, sex, stage), histologic (depth of invasion, level, type) and prognostic (recurrence, death) parameters. Single nuclear suspensions were obtained from fixed, paraffin-embedded tumor and adjacent normal tissue processed separately according to Hedley's technique. These, a "spiked" specimen of normal tissue and tumor, and a spleen diploid control were analyzed on a FACScan flow cytometer (Becton Dickinson, Mountain View, California, U.S.A.). Feulgen-stained Cytocentrifuge preparations of nuclear suspensions of normal, MM and diploid spleen were analyzed with the CAS 200 Image Analyzer (Cell Analysis Systems, Inc., Elmhurst, Illinois, U.S.A.) against commercial calibration rat hepatocytes defined as diploid. Six (37.5%) MM were diploid, and 10 (62.5%) were aneuploid; 8 (90%) were hypodiploid, for a high frequency. There were no statistically significant correlations between clinical, pathologic, prognostic or cell cycle analysis parameters and ploidy, although poor prognostic features tended to be in aneuploid lesions.  相似文献   

19.
BACKGROUND: Phycobiliproteins play an important role in fluorescent labeling, particularly for flow cytometry. The spectral properties of R-phycoerythrin (R-PE) and allophycocyanin (APC) have made them the dominant reagents in this class of fluorochromes. In this study, we evaluate a lesser-known but potentially important series of low-molecular weight cryptomonad-derived phycobiliproteins (commercially termed the CryptoFluortrade mark dyes) for their applicability to flow cytometry, both in extracellular and intracellular labeling applications. METHODS: Several cell lines were labeled with biotin-conjugated antibodies against expressed extracellular surface proteins, followed by streptavidin conjugates of three cryptomonad phycobiliproteins (CryptoFluor-2, CryptoFluor-4, and CryptoFluor-5). Cells were then analyzed by flow cytometry using a variety of laser lines and emission filters to establish the optimal excitation/emission characteristics for each fluorochrome. Some cells were permeabilized and labeled for intracellular antigens, also using the cryptomonad fluorochromes. Where appropriate, parallel samples were labeled with other fluorochromes (including R-PE, APC, the cyanin dyes Cy3 and Cy5, and others) to gauge the performance of the cryptomonad fluorochromes against fluorescent labels previously evaluated for flow cytometry. RESULTS: CryptoFluor-2 possessed excitation/emission maxima similar to those of APC and Cy5, with good excitation in the red (HeNe laser 632 nm) and strong emission in the far red (660 nm). CryptoFluor-4 possessed excitation/emission maxima similar to those of Cy3, with optimal excitation in the green (Kr 530 nm) and strong emission in the yellow/orange (585 nm). CryptoFluor-5 possessed excitation/emission maxima similar to those of lissamine rhodamine, with optimal excitation in the yellow (Kr 568 nm) and emission in the orange (610 nm). All cryptomonad fluorochromes gave satisfactory results for both intracellular and extracellular labeling, with detection sensitivities that were comparable or better than traditional phycobiliproteins and low- molecular weight synthetic fluorochromes such as the cyanin dyes. CONCLUSIONS: The CryptoFluor fluorochromes were applicable to flow cytometric immunodetection, with excitation and emission conditions commonly found on multilaser instruments. Performance of several of these dyes was at least comparable to existing fluorescent labels. The low molecular weights (30-60 kd) of phycobiliproteins may make them particularly useful in intracellular antigen detection. Cytometry 44:16-23, 2001. Published 2001 Wiley-Liss, Inc.  相似文献   

20.
A C Begg  I Hofland 《Cytometry》1991,12(5):445-454
The development of antibodies to DNA-incorporated thymidine analogs has in turn led to the development of flow cytometric techniques for rapidly measuring cell kinetics parameters. More recently, these techniques have been applied to clinical tumor material. One problem with such measurements has been the difficulty of distinguishing malignant cells from coexistent normal cells in the biopsy material. In the present study, the feasibility of selecting out the desired malignant cell population for kinetic analysis from a mixture of cells was tested in vitro. An anticytokeratin antibody was used to discriminate between a mixture of tumor cells (cytokeratin positive) and normal cells (cytokeratin negative). The cell lines chosen for the study, A549 human lung carcinoma cells and Chinese hamster ovary (CHO) cells, were pulse labeled with iododeoxyuridine (IdUrd) and sampled every hour up to 16 hours. Selecting out cells from the mixture required the application of three-color fluorescence flow cytometry, which was carried out using the fluorochromes FITC (fluorescein isothionate, green fluorescence, IdUrd-DNA antibody), PE (phycoerythrin, orange fluorescence, cytokeratin antibody), and PI (propidium iodide, red fluorescence, DNA). This allowed single laser excitation. The staining procedure involved incubation with the IdUrd antibodies (specific antibody plus FITC-conjugated second antibody) followed by the cytokeratin antibodies (specific antibody plus PE-conjugated second antibody) and lastly by the DNA stain containing RNase. Two analysis methods of the IdUrd/DNA cytograms were applied: a mid-S window analysis and a relative movement (RM) analysis. Results of the analyses for cells selected out of mixtures were compared with results of cells stained and analyzed separately. A clear separation of the two cell lines could be obtained on the basis of orange fluorescence (cytokeratin content) despite a large overlap of their DNA histograms. By gating on high or low orange fluorescence, almost pure populations of the individual cell types could be selected out for further kinetic analysis. Little difference was seen, with both the mid-S and RM analyses, between cells gated from mixtures or stained separately. It is concluded that this technique is feasible for use on clinical material, provided good cell suspensions can be obtained, leading to the hope of increasing the accuracy of kinetic measurements on human tumors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号