首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive method has been developed and validated for the determination of artesunate and its active metabolite dihydroartemisinin (DHA) in human plasma using artemisinin as an internal standard. Solid phase extraction (SPE) using Oasis HLB extraction cartridges was used for sample preparation and analysis was performed on a Shimadzu LCMS-2010 in single ion monitoring positive mode using atmospheric pressure chemical ionization (APCI) as an interface. Positive ions were measured using extracted ion chromatogram mode. The extracted ion for artesunate, alpha- and beta-DHA was m/z 221 and for artemisinin was m/z 283. Chromatography was carried out using a Synergi Max-RP, 4 mu, 75 mm x 4.6 mm column using glacial acetic acid 0.1%, acetonitrile and methanol mixture (38:46.5:15.5) as a mobile phase delivered at a flow rate of 0.5 mL/min. The retention times of artesunate, alpha- and beta-DHA and artemisinin were 17.4, 11.8, 18.7 and 13.4 min, respectively, with a total run time of 21 min. The assay was linear over the range 1-3000 ng/mL for artesunate and DHA. The analysis of quality control samples for artesunate 50, 300, 1300 and 2600 ng/mL demonstrated excellent precision with relative standard deviation of 14.3, 11.3, 7.5 and 12.1%, respectively (n=5). Recoveries at concentration of 50, 300, 1300 and 2600 ng/mL were 75, 94.5, 74.3 and 75.5%, respectively; similar results were obtained for precision and recovery of DHA. This liquid chromatography-mass spectroscopy (LC-MS) method for the determination of artesunate and DHA in human plasma has superior specification for sensitivity, sample throughput and robustness than previous methods and can reliably quantitate concentrations of both (artesunate and DHA) compounds as low as 1 ng/mL.  相似文献   

2.
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine.  相似文献   

3.
A high throughput bioanalytical assay for the determination of lumefantrine in plasma has been developed and validated extensively. The within-day precisions for lumefantrine were 5.2, 3.5 and 2.5% at 200, 2000 and 15000 ng/mL, respectively. The between-day precisions were 4.0, 2.8 and 3.1% at 200, 2000 and 15000 ng/mL, respectively. The lower limits of quantification (LLOQ) and the limits of detection (LOD) were 25 and 10 ng/mL, respectively using 0.250 mL plasma. The average recovery of lumefantrine was 85% and independent upon concentration. The use of 96-well plate format and short chromatographic run has increased the daily sample throughput four times. The assay is particularly suitable for large therapeutic drug monitoring studies using day 7 sampling.  相似文献   

4.
Licea-Perez H  Wang S  Szapacs ME  Yang E 《Steroids》2008,73(6):601-610
A highly sensitive and selective quantitative method to accurately determine testosterone (Te) and 5alpha-dihydrotestosterone (DHT) in human serum is crucial to the success of Te replacement therapy for hypogonadism. To this end we have developed and validated a semi-automated and relatively high-throughput method in a 96-well plate format using ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC/MS/MS) for the simultaneous determination of Te and DHT in human serum. Te and DHT along with the internal standards [(2)H(3)]-Te and [(2)H(3)]-DHT were extracted from 300 microL of human serum by liquid-liquid extraction using methyl tertiary-butyl ether (MTBE), followed by derivatization with 2,3-pyridinedicarboxylic anhydride and solid-phase extraction for sample clean up. A novel chemical derivatization approach using 2,3-pyridinedicarboxylic anhydride was employed to achieve the MS sensitivity and selectivity required for DHT. Baseline separation of Te and DHT derivatives from endogenous steroid derivatives was achieved using UPLC technology on a C18 stationary-phase column with 1.7 microm particle size. The validity of using double charcoal-stripped female human serum as surrogate matrix for preparation of calibration standards was demonstrated through standard addition experiments. The method was validated over the concentration ranges of 0.2-40 ng/mL for Te and 0.01-2 ng/mL for DHT. The validation and study sample analysis results show that the method is rugged, precise, accurate, and well suited to support pharmacokinetic studies where approximately 300 samples can be extracted and analyzed in 1 day.  相似文献   

5.
A sensitive method was developed and validated for the measurement of 17-(allylamino)-17-demethoxygeldanamycin (17AAG) and its active metabolite 17-amino-17-demethoxygeldanamycin (17AG) in human plasma using 17-(dimethylaminoethylamino)-17-demethoxygeldanamycin (17DMAG) as an internal standard. After the addition of internal standard, 200 microL of plasma was extracted using ice cold acetonitrile followed by analysis on a Thermo Finnigan triple-quadruple mass spectrometer coupled to an Agilent 1100 HPLC system. Chromatography was carried out on a 50 mm x 2.1 mm Agilent Zorbax SB-phenyl 5 microm column coupled to a 3mm Varian metaguard diphenyl pre-column using glacial acetic acid 0.1% and a gradient of acetonitrile and water at a flow rate of 500 microL/min. Atmospheric pressure chemical ionization and detection of 17AAG, 17AG and 17DMAG were accomplished using selected reaction monitoring of m/z 584.3>541.3, 544.2>501.2, and 615.3>572.3, respectively in negative ion mode. Retention times for 17AAG, 17AG, and 17DMAG were 4.1, 3.5, and 2.9 min, respectively, with a total run time of 7 min. The assay was linear over the range 0.5-3000 ng/mL for 17AAG and 17AG. Replicate sample analysis indicated within- and between-run accuracy and precision within 15%. The recovery of 17AAG and 17AG from 200 microL of plasma containing 1, 25, 300, and 2500 ng/mL was 93% or greater. This high-performance liquid chromatographic tandem mass spectroscopy (HPLC/MS/MS) method is superior to previous methods. It is the first analytical method reported to date for the quantitation of both 17AAG and its metabolite 17AG and can reliably quantitate concentrations of both compounds as low as 0.5 ng/mL.  相似文献   

6.
A sensitive, specific and high throughput bioanalytical method using automated sample processing via 96-well plate liquid-liquid extraction and ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) has been developed for the determination of methoxsalen in human plasma. Plasma samples with ketoconazole as internal standard (IS) were prepared by employing 0.2mL human plasma in ethyl acetate:dichloromethane (80:20, v/v). The chromatographic separation was achieved on a Waters Acquity UPLC BEH C18 column using isocratic mobile phase, consisting of 10mM ammonium formate and acetonitrile (60:40, v/v), at a flow rate of 0.5mL/min. The linear dynamic range was established over the concentration range 1.1-213.1ng/mL for methoxsalen. The method was rugged and rapid with a total run time of 1.5min. It was successfully applied to a pivotal bioequivalence study in 12 healthy human subjects after oral administration of 10mg extended release methoxsalen formulation under fasting condition.  相似文献   

7.
A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV相似文献   

8.
An accurate and precise method was developed using HPLC-MS/MS to quantify erlotinib (OSI-774) and its O-desmethyl metabolite, OSI-420, in plasma. The advantages of this method include the use of a small sample volume, liquid-liquid extraction with high extraction efficiency and short chromatographic run times. The analytes were extracted from 100 microL plasma volume using hexane:ethyl acetate after midazolam was added to the sample for internal standardization. The compounds were separated on a Phenomenex C-18 Luna analytical column with acetonitrile:5 mM ammonium acetate as the mobile phase. All compounds were monitored by tandem mass spectrometry with electrospray positive ionization. The intra-day accuracy and precision (% coefficient of variation, % CV) estimates for erlotinib at 10 ng/mL were 90% and 9%, respectively. The intra-day accuracy and precision estimates for OSI-420 at 5 ng/mL were 80% and 4%, respectively. This method was used to quantify erlotinib and OSI-420 in plasma of patients (n=21) administered 150 mg erlotinib per day for non-small cell lung cancer.  相似文献   

9.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of schizandrin in rat plasma was developed and validated after solid-phase extraction (SPE). Chromatographic separation was achieved on a reversed-phase Shimadzu C(18) column with the mobile phase of acetonitrile-sodium acetate (10 micromol/L) and step gradient elution resulted in a total run time of about 11.7 min. The analytes were detected using an electrospray positive ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.000 microg/mL) (r=0.9999). Lower limit of quantification (LLOQ) was 5 ng/mL and the lower limit of detection (LLOD) was 2 ng/mL using 100 microL plasma sample. Average recoveries ranged from 75.85 to 88.51% in plasma at the concentrations of 0.005, 0.100 and 1.000 microg/mL. Intra- and inter-day relative standard deviations were 5.95-12.93% and 3.87-14.53%, respectively. This method was successfully applied for the pharmacokinetic studies in rats.  相似文献   

10.
A robust and validated liquid-liquid extraction LC-MS/MS method was developed for population pharmacokinetic analysis and therapeutic drug monitoring of risperidone and the enantiomers of its major active metabolite (+)-and (-)9-hydroxyrisperidone in pediatric patients. The method was rapid, sensitive and used a low sample amount (200 microL), which is very desirable for the pediatric population. The assay was validated from 0.2 to 50 ng/mL in plasma for all analytes. LLOQ for all analytes was 0.2 ng/mL. The extracts were analyzed by normal phase LC-MS/MS. The sample run time was 8 min. Intra- and interday precision for all analytes was < or =6%; method accuracy was between 89 and 99%. Additional experiments were performed to analyze matrix effects and identify a proper internal standard for each analyte. The validated method was used to study risperidone and its enantiomer metabolites in plasma as part of a population pharmacokinetic study in pediatric patients with pervasive developmental disorder (PDD).  相似文献   

11.
A simple and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method using an atmospheric pressure chemical ionization source (APCI) for the quantification of fenretinide (4-HPR) in mouse plasma was developed and validated. After a simple protein precipitation of plasma sample by acetonitrile, 4-HPR was analyzed by LC-APCI-MS/MS. High-performance liquid chromatography (HPLC) separation was conducted on a Hypurity C18 column (50mmx2.1mm, 5microm) with a flow rate 0.60mL/min using a gradient mobile phase comprised of 0.05% formic acid in water (A) and methanol (B), and a run time of 4.5min. The elimination of a tedious sample preparation process and a shorter run time substantially reduced total analysis time. The method was linear over the range 0.5-100ng/mL, with r>0.998. The intra- and inter-assay precisions were 1.4-9.2% and 5.1-8.2%, respectively, and the intra- and inter-assay accuracies were 93.9-98.6% and 92.7-95.3%, respectively. The absolute recoveries were 90.3% (1.5ng/mL), 97.0% (7.5ng/mL) and 92.1% (75.0ng/mL) for 4-HPR, and 99.1% for the internal standard (150ng/mL). The analytical method had excellent sensitivity using a small sample volume (30microL) with the lower limit of quantification (LLOQ) 0.5ng/mL. This method is robust and has been successfully employed in a pharmacokinetic study of 4-HPR in a mouse xenograft model of neuroblastoma.  相似文献   

12.
An automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for quantitative determination of donepezil in human plasma. 150 MicroL of plasma samples were placed in 2.2 mL 96-deepwell plates and both donepezil and loratadine (IS) were extracted from human plasma by liquid-liquid extraction (LLE), using hexane as the organic solvent. Robotic liquid handling workstations were employed for all liquid transfer and solution preparation steps and resulted in a short sample preparation time. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of reconstitution solution. The method developed, includes a sample analysis performed by reversed phase LC-MS/MS, with positive ion electrospray ionization, using multiple reaction monitoring (MRM). The chromatographic run time was set for 2.0 min with a flow rate of 0.7 mL/min in a C18 analytical column. The method was significantly sensitive, specific, accurate and precise for the determination of donepezil in human plasma and had the shortest run time. The curve was proven to be linear for the concentration range of 0.1-100 ng/mL. After validation, the method was applied to the rapid and reliable quantitative determination of donepezil in a bioequivalence study after per os administration of a 5mg donepezil tablet.  相似文献   

13.
A fast, sensitive and selective ultra performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method was developed for the determination of nifedipine in human plasma. Nitrendipine was used as the internal standard. The sample preparation employed liquid-liquid extraction with a mixture of n-hexane-diethyl ether (1:3, v/v). Chromatographic separation was performed on an ACQUITY UPLC? BEH C(18) column. The mobile phase was composed of acetonitrile-10 mmol/L ammonium acetate (75:25, v/v) with a flow rate of 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. A high throughput was achieved with a run time of 1.4 min per sample. The linear calibration curves were obtained in the concentration range of 0.104-52.0 ng/mL (r(2)≥ 0.99) with a lower limit of quantification (LLOQ) of 0.104 ng/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were below 15% and the accuracy (relative error, RE) was -4.0% to 6.2% at three quality control levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of nifedipine sustained-release tablet in healthy male volunteers.  相似文献   

14.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of a potent 5-HT(1B/1D) receptor agonist, rizatriptan in human plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 100 microL plasma samples by liquid-liquid extraction (LLE) and chromatographed on a Lichrospher C18 column (4.6mm x 50mm, 5 microm) with a mobile phase consisting of acetonitrile-10mM aqueous ammonium acetate-acetic acid (50:50:0.5, v/v/v) pumped at 1.0 mL/min. The method had a chromatographic total run time of 2 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 270-->201 (rizatriptan) and 313.4-->138 (granisetron) used for quantitation. The assay was validated over the concentration range of 0.05-50 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was above 98%. The intra-day accuracy of the assay was within 12% of nominal and intra-day precision was better than 13% C.V. Following a 10mg dose of the compound administered to human subjects, mean concentrations of rizatriptan ranged from 0.2 to 70.6 ng/mL in plasma samples collected up to 24h after dosing. Inter-day accuracy and precision results for quality control samples run over a 5-day period alongside clinical samples showed mean accuracies of within 12% of nominal and precision better than 9.5% C.V.  相似文献   

15.
A precise, sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of trazodone (TRZ) and its primary metabolite, m-chlorophenylpiperazine (mCPP), in human plasma was developed and validated. The analytes and the internal standard-nefazodone were extracted from 500 microL aliquots of human plasma via liquid-liquid extraction in n-hexane. Chromatographic separation was achieved in a run time of 2.5 min on a Betabasic cyano column (100 mm x 2.1 mm, 5 microm) under isocratic conditions. Detection of analytes and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for TRZ, mCPP and IS were m/z 372.2-->176.2, 197.2-->118.1 and 470.5-->274.6 respectively. The method was fully validated for its sensitivity, selectivity, accuracy and precision, matrix effect, stability study and dilution integrity. A linear dynamic range of 10.0-3000.0 ng/mL for TRZ and 0.2-60.0 ng/mL for mCPP was evaluated with mean correlation coefficient (r) of 0.9986 and 0.9990 respectively. The intra-batch and inter-batch precision (%CV) across five validation runs (LLOQ, lower limit of quantitation; LQC, low quality control; MQC, middle quality control; HQC, high quality control and ULOQ, upper limit of quantitation) was < or =8.4% for both the analytes. The method was successfully applied to a bioequivalence study of 100mg trazodone tablet formulation in 36 healthy Indian male subjects under fasting and fed conditions.  相似文献   

16.
A new drug, quick-acting anti-motion capsule (QAAMC) composed of d-amphetamine sulfate, dimenhydrinate and ginger extraction has been studied for anti-motion-sickness use. We have developed a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantitative determination of d-amphetamine and diphenhydramine, the main effective components of the QAAMC, using pseudoephedrine as the internal standard. The analytes and internal standard were isolated from 200 microL plasma samples by a simple liquid-liquid extraction (LLE). Reverse-phase HPLC separation was accomplished on a Zorbax SB-C18 column (100 mm x 3.0 mm, 3.5 microm) with a mobile phase composed of methanol-water-formic acid (65:35:0.5, v/v/v) at a flow rate of 0.2 mL/min. The method had a chromatographic total run time of 5 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 136.0-->91.0 (D-amphetamine), 256.0-->167.0 (diphenhydramine) and 166.1-->148.0 (IS) used for quantitation. The method was sensitive with a lower limit of quantitation (LLOQ) of 0.5 ng/mL for d-amphetamine and 1 ng/mL for diphenhydramine, with good linearity in the range 0.5-200 ng/mL for D-amphetamine and 1-500 ng/mL for diphenhydramine (r(2)> or =0.9990). All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic study of the QAAMC in beagle dogs.  相似文献   

17.
Cyclophosphamide is a cytotoxic prodrug with a very narrow therapeutic index. To study the clinical pharmacology of cyclophosphamide in a large cohort of patients a previously published method for the simultaneous quantitative determination of cyclophosphamide and 4-hydroxycyclophosphamide in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS) was optimized. Addition of an isotopically labelled internal standard and adaptation of the gradient resulted in a fast, robust and sensitive assay. Because 4-hydroxycyclophosphamide is not stable in plasma, the compound is derivatized with semicarbazide immediately after sample collection. Sample preparation was carried out by protein precipitation with methanol-acetonitrile (1:1, v/v), containing isotopically labelled cyclophosphamide and hexamethylphosphoramide as internal standards. The LC separation was performed on a Zorbax Extend C18 column (150 mm x 2.1 mm ID, particle size 5 microm) with 1 mM ammonium hydroxide in water-acetonitrile (90:10, v/v) as the starting gradient, at a flow-rate of 0.40 mL/min with a total run time of 6 min. The lower limit of quantification (LLQ, using a 100 microL sample volume) was 200 ng/mL and the linear dynamic range extended to 40,000 ng/mL for cyclophosphamide and 50-5000 ng/mL for 4-hydroxycyclophosphamide. Accuracies as well as precisions were lower than 20% at the LLQ concentration and lower than 15% for all other concentrations. This method has been successfully applied in our institute to support ongoing studies into the pharmacokinetics and pharmacogenetics of cyclophosphamide.  相似文献   

18.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of ginsenoside Rd in dog plasma was developed and validated after solid-phase extraction (SPE).Chromatographic separation was achieved on a reversed-phase Cromosil C(18) column with the mobile phase of acetonitrile-ammonium chloride (500 micromol/L) and step gradient elution resulted in a total run time of about 5.5 min. The analytes were detected by using an electrospray negative ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.500 microg/mL) (r=0.9998). Lower limit of quantification (LLOQ) was 5 ng/mL by using 500 microL plasma sample. Average recoveries ranged from 70.71 to 75.89% in plasma at the concentrations of 0.010, 0.100 and 2.500 microg/mL. Intra- and inter-day relative standard deviations were 8.49-11.71 and 5.71-16.48%, respectively. This method was successfully applied to the pharmacokinetic studies on dogs. The absolute bioavailability of Rd in dogs was 0.26%.  相似文献   

19.
Direct plasma injection technology coupled with a LC-MS/MS assay provides fast and straightforward method development and greatly reduces the time for the tedious sample preparation procedures. In this work, a simple and sensitive bioanalytical method based on direct plasma injection using a single column high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) was developed for direct cocktail analysis of double-pooled mouse plasma samples for the quantitative determination of small molecules. The overall goal was to improve the throughput of the rapid pharmacokinetic (PK) screening process for early drug discovery candidates. Each pooled plasma sample was diluted with working solution containing internal standard and then directly injected into a polymer-coated mixed-function column for sample clean-up, enrichment and chromatographic separation. The apparent on-column recovery of six drug candidates in mouse plasma samples was greater than 90%. The single HPLC column was linked to either an atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI) source as a part of MS/MS system. The total run cycle time using single column direct injection methods can be achieved within 4 min per sample. The analytical results obtained by the described direct injection methods were comparable with those obtained by semi-automated protein precipitation methods within +/- 15%. The advantages and challenges of using direct single column LC-MS/MS methods with two ionization sources in combination of sample pooling technique are discussed.  相似文献   

20.
An original HPLC-UV method has been developed for the simultaneous determination of the atypical antipsychotic quetiapine and the geometric isomers of the second-generation antidepressant fluvoxamine. The analytes were separated on a reversed-phase C8 column (150 mm x 4.6mm i.d., 5 microm) using a mobile phase composed of acetonitrile (30%) and a 10.5mM, pH 3.5 phosphate buffer containing 0.12% triethylamine (70%). The flow rate was 1.2 mL min(-1) and the detection wavelength was 245 nm. Sample pretreatment was carried out by an original solid-phase extraction procedure using mixed-mode cation exchange (DSC-MCAX) cartridges; only 300 microL of plasma were needed for one analysis. Citalopram was used as the internal standard. The method was validated in terms of linearity, extraction yield, precision and accuracy. Good linearity was obtained in plasma over the 5.0-160.0 ng mL(-1) concentration range for each fluvoxamine isomer and over the 2.5-400.0 ng mL(-1) concentration range for quetiapine. Extraction yield values were always higher than 93%, with precision (expressed as relative standard deviation values) better than 4.0%. The method was successfully applied to human plasma samples drawn from patients undergoing polypharmacy with the two drugs. Satisfactory accuracy values were obtained, with mean recovery higher than 94%.  相似文献   