首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Biofilms are considered a significant health risk in the food and dairy industries because they can harbor pathogens, and direct contact with them can lead to food contamination. Biofilm control is often performed using strong oxidizing agents like chlorine and peracetic acid. Although chlorine dioxide (ClO2) is being used increasingly to control microbiological growth in a number of different industries, not much is known about disinfection in biofilms using chlorine dioxide. In this study, a microelectrode originally made for chlorine detection was modified to measure the profiles of chlorine dioxide in biofilm as a function of depth into the biofilm. In addition, discarded microelectrodes proved useful for in situ direct measurement of biofilm thicknesses. The chlorine dioxide microelectrode had a linear response when calibrated up to a ClO2 concentration of 0.4 mM. ClO2 profiles showed depletion of disinfectant at 100 μm in the biofilm depth, indicating that ClO2 may not reach bacteria in a biofilm thicker than this using a 25 mg/l solution.  相似文献   

2.
AIMS: The influence of two disinfection techniques on natural biofilm development during drinking water treatment and subsequent distribution is compared with regard to the supply of a high-quality drinking water. METHODS AND RESULTS: The growth of biofilms was studied using the biofilm device technique in a real public technical drinking water asset. Different pipe materials which are commonly used in drinking water facilities (hardened polyethylene, polyvinyl chloride, steel and copper) were used as substrates for biofilm formation. Apart from young biofilms, several months old biofilms were compared in terms of material dependence, biomass and physiological state. Vital staining of biofilms with 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) and the DNA-specific 4',6-diamidino-2-phenylindole (DAPI) staining resulted in a significant difference in physiological behaviour of biofilm populations depending on the disinfection technique. Compared with chlorine dioxide disinfection (0.12-0.16 mg l-1), the respiratory activities of the micro-organisms were increased on all materials during u.v. disinfection (u.v.254; 400 J m-2). The biofilm biocoenosis was analysed by in situ hybridization with labelled oligonucleotides specific for some subclasses of Proteobacteria. Using PCR and additional hybridization techniques, the biofilms were also tested for the presence of Legionella spp., atypical mycobacteria and enterococci. The results of the molecular-biological experiments in combination with cultivation tests showed that enterococci were able to pass the u.v. disinfection barrier and persist in biofilms of the distribution system, but not after chlorine dioxide disinfection. CONCLUSIONS: The results indicated that bacteria are able to regenerate and proliferate more effectively after u.v. irradiation at the waterworks, and chlorine dioxide disinfection appears to be more applicative to maintain a biological stable drinking water. SIGNIFICANCE AND IMPACT OF THE STUDY: As far as the application of u.v. disinfection is used for conditioning of critical water sources for drinking water, the efficiency of u.v. irradiation in natural systems should reach a high standard to avoid adverse impacts on human health.  相似文献   

3.
Fluorescent stains in conjunction with cryoembedding and image analysis were applied to demonstrate spatial gradients in respiratory activity within bacterial biofilms during disinfection with monochloramine. Biofilms of Klebsiella pneumoniae and Pseudomonas aeruginosa grown together on stainless steel surfaces in continuous-flow annular reactors were treated with 2 mg of monochloramine per liter (influent concentration) for 2 h. Relatively little biofilm removal occurred as evidenced by total cell direct counts. Plate counts (of both species summed) indicated an average 1.3-log decrease after exposure to 2 mg of monochloramine per liter. The fluorogenic redox indicator 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) and the DNA stain 4',6-diamidino-2-phenylindole (DAPI) were used to differentiate respiring and nonrespiring cells in biofilms. Epifluorescence micrographs of frozen biofilm cross sections clearly revealed gradients of respiratory activity within biofilms in response to monochloramine treatment. These gradients in specific respiratory activity were quantified by calculating the ratio of CTC and DAPI intensities measured by image analysis. Cells near the biofilm-bulk fluid interface lost respiratory activity first. After 2 h of biocide treatment, greater respiratory activity persisted deep in the biofilm than near the biofilm-bulk fluid interface.  相似文献   

4.
A model biofilm, formed of multiple species from environmental drinking water, including opportunistic pathogens, was created to explore the tolerance of multi-species biofilms to chlorine levels typical of water-distribution systems. All species, when grown planktonically, were killed by concentrations of chlorine within the World Health Organization guidelines (0.2–5.0?mg?l?1). Higher concentrations (1.6–40-fold) of chlorine were required to eradicate biofilm populations of these strains, ~70% of biofilms tested were not eradicated by 5.0?mg?l?1 chlorine. Pathogenic bacteria within the model multi-species biofilms had an even more substantial increase in chlorine tolerance; on average ~700–1100?mg?l?1 chlorine was required to eliminate pathogens from the biofilm, 50–300-fold higher than for biofilms comprising single species. Confocal laser scanning microscopy of biofilms showed distinct 3D structures and multiple cell morphologies and arrangements. Overall, this study showed a substantial increase in the chlorine tolerance of individual species with co-colonization in a multi-species biofilm that was far beyond that expected as a result of biofilm growth on its own.  相似文献   

5.
Enzymatic removal and disinfection of bacterial biofilms.   总被引:8,自引:2,他引:8       下载免费PDF全文
C Johansen  P Falholt    L Gram 《Applied microbiology》1997,63(9):3724-3728
Model biofilms of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas fluorescens, and Pseudomonas aeruginosa were made on steel and polypropylene substrata. Plaque-resembling biofilms of Streptococcus mutans, Actinomyces viscosus, and Fusobacterium nucleatum were made on saliva-coated hydroxyapatite. The activity of enzymes against bacterial cells in biofilm was measured by fluorescence microscopy and an indirect conductance test in which evolution of carbon dioxide was measured. Glucose oxidase combined with lactoperoxidase was bactericidal against biofilm bacteria but did not remove the biofilm from the substrata. A complex mixture of polysaccharide-hydrolyzing enzymes was able to remove bacterial biofilm from steel and polypropylene substrata but did not have a significant bactericidal activity. Combining oxidoreductases with polysaccharide-hydrolyzing enzymes resulted in bactericidal activity as well as removal of the biofilm.  相似文献   

6.
Biofilm bacteria challenged with monochloramine retained significant respiratory activity, even though they could not be cultured on agar plates. Microbial colony counts on agar media declined by approximately 99.9% after 1 h of disinfection, whereas the number of bacteria stained by a fluorescent redox dye experienced a 93% reduction. Integrated measures of biofilm respiratory activity, including net oxygen and glucose utilization rates, showed only a 10 to 15% reduction. In this biofilm system, measures of microbial respiratory activity and culturability yielded widely differing estimates of biocide efficacy.  相似文献   

7.
The penetration of hydrogen peroxide into biofilms formed by wild-type and catalase-deficient Pseudomonas aeruginosa strains was measured using microelectrodes. A flowing stream of hydrogen peroxide (50 mM, 1 h) was unable to penetrate or kill wild-type biofilms but did penetrate and partially kill biofilms formed by an isogenic strain in which the katA gene was knocked out. Catalase protects aggregated bacteria by preventing full penetration of hydrogen peroxide into the biofilm.  相似文献   

8.
Direct measurements of the pH within natural marine biofilms grown on platinum have been made with iridium/iridium oxide solid‐state microelectrodes. The data show that the pH is highly variable, with steep gradients both perpendicular to and along the metal surface. Measured values ranged from 8 in the outer portions of the biofilm to below 2 in localized areas near the metal surface. It was verified that bulk water flowing along the hydrophilic outer sheath of the micro‐electrode could effect the measured pH values. However, meaningful data could still be taken because the response time of the electrode was sufficiently less than the time for water ingression. The data presented are consistent with recent heterogeneous biofilm models and with the idea that localized areas of low pH within biofilms can be a contributing factor in biologically influenced corrosion processes.  相似文献   

9.
Physiological responses of bacteria in biofilms to disinfection.   总被引:1,自引:1,他引:1       下载免费PDF全文
In situ enumeration methods using fluorescent probes and a radioisotope labelling technique were applied to evaluate physiological changes of Klebsiella pneumoniae within biofilms after disinfection treatment. Chlorine (0.25 mg of free chlorine per liter [pH 7.2]) and monochloramine (1 mg/liter [pH 9.0]) were employed as disinfectants in the study. Two fluorgenic compounds, 5-cyano-2,3-ditolyl tetrazolium chloride and rhodamine 123, and tritiated uridine incorporation were chosen for assessment of physiological activities. Results obtained by these methods were compared with those from the plate count and direct viable count methods. 5-Cyano-2,3-ditolyl tetrazolium chloride is an indicator of bacterial respiratory activity, rhodamine 123 is incorporated into bacteria in response to transmembrane potential, and the incorporation of uridine represents the global RNA turnover rate. The results acquired by these methods following disinfection exposure showed a range of responses and suggested different physiological reactions in biofilms exposed to chlorine and monochloramine. The direct viable count response and respiratory activity were affected more by disinfection than were the transmembrane potential and RNA turnover rate on the basis of comparable efficiency as evaluated by plate count enumeration. Information revealed by these approaches can provide different physiological insights that may be used in evaluating the efficacy of biofilm disinfection.  相似文献   

10.
A novel micromanipulation technique has been developed to measure directly the adhesive strength of biofilms formed in pipe flows. A T-shaped probe was specially designed to pull Pseudomonas fluorescens biofilms away from the inner surface of a pipe to which they were attached. The adhesive strength between biofilms and the substratum was defined as the work required to remove the biofilms per unit area from the substratum. Results showed that the adhesive strength increased with the fluid velocity in which the biofilms were grown, with a typical value of 0.050.2 J/m2. © Rapid Science Ltd. 1998  相似文献   

11.
Surface-catalysed disinfection of thick Pseudomonas aeruginosa biofilms   总被引:2,自引:0,他引:2  
Transition metal catalysts were incorporated into polymers which formed the surface for bacterial attachment and biofilm formation in a constant depth film fermenter (100 μm thickness), flow chamber (about 30 μm thickness) and in batch culture (<30 μm thickness). The catalysts drive the breakdown of persulphates to reactive oxygen species. When Pseudomonas aeruginosa biofilms were exposed to dilute solutions of potassium monopersulphate (20 μg ml−1–1 mg ml−1), significant enhancement of killing was notable for catalyst-containing surfaces over that of controls. The degree of enhancement was greatest for thin films, but was nevertheless significant for the 100 μm thick biofilms. Fluorescence probes and viability staining, in conjunction with laser confocal microscopy, showed that reactive species were generated at the biofilm–substratum interface and killed the biofilm from the inside. Reaction-diffusion limitation now concentrates the active species within the biofilm rather than protecting it, and a diffusion pump is established whereby further treatment agent is drawn to the substratum enabling relatively thick biofilms to be disinfected.  相似文献   

12.
Although the detachment of cells from biofilms is of fundamental importance to the dissemination of organisms in both public health and clinical settings, the disinfection efficacies of commonly used biocides on detached biofilm particles have not been investigated. Therefore, the question arises whether cells in detached aggregates can be killed with disinfectant concentrations sufficient to inactivate planktonic cells. Burkholderia cepacia and Pseudomonas aeruginosa were grown in standardized laboratory reactors as single species and in coculture. Cluster size distributions in chemostats and biofilm reactor effluent were measured. Chlorine susceptibility was assessed for planktonic cultures, attached biofilm, and particles and cells detached from the biofilm. Disinfection tolerance generally increased with a higher percentage of larger cell clusters in the chemostat and detached biofilm. Samples with a lower percentage of large clusters were more easily disinfected. Thus, disinfection tolerance depended on the cluster size distribution rather than sample type for chemostat and detached biofilm. Intact biofilms were more tolerant to chlorine independent of species. Homogenization of samples led to significantly increased susceptibility in all biofilm samples as well as detached clusters for single-species B. cepacia, B. cepacia in coculture, and P. aeruginosa in coculture. The disinfection efficacy was also dependent on species composition; coculture was advantageous to the survival of both species when grown as a biofilm or as clusters detached from biofilm but, surprisingly, resulted in a lower disinfection tolerance when they were grown as a mixed planktonic culture.  相似文献   

13.
Bioassay and dose measurement in UV disinfection.   总被引:3,自引:3,他引:0       下载免费PDF全文
A bioassay method was developed to measure the average intensity within a UV disinfection reactor. The survival of spores of Bacillus subtilis was determined as a function of UV dose to prepare a standard curve. Spores were added to unknown systems, and the survival rate was used to determine the average intensity. A modification was used for flow-through reactors by which spores were injected as a spike and collected at a known time after injection. A point source summation method for calculating intensity was verified by bioassay measurements in a simple cylinder. This calculation method was also applied to multiple-lamp reactors.  相似文献   

14.
For several years, it has been possible to determine renin by a direct RIA. In the present study, plasma active renin concentration (PRC) was related to plasma renin activity (PRA) and aldosterone as a function of a standardized posture test. Using PRC, our target was to define the shortest necessary test duration. The three parameters were examined in 10 healthy male subjects (22-34 years old). Salt balance was determined in 24-hour urine, and plasma potassium and sodium were measured. Volunteers were hospitalized for 1 night, and at 8 a.m. the next morning they were subjected to the following postural changes: 3 h active orthostasis and 3 h recumbency. Frequent blood samples were taken. Orthostasis induced a significant rise in PRC, PRA and aldosterone already after 15 min. PRC and PRA reached a maximum level after 90 min of orthostasis and remained relatively stable, while aldosterone reached its highest level already after 30 min and then gradually decreased. Significant correlations were found between PRA and PRC (p < 0.001), between PRC and aldosterone (p < 0.001), and between PRA and aldosterone (p < 0.001). The PRC/PRA ratio changed during the course of the test, especially in supine subjects. When subjects returned to the supine position, all the parameters measured began a continual decrease. There were no significant changes in serum potassium and sodium levels throughout the duration of the test.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
Bacterial biofilms are a growing concern in a broad range of areas. In this study, a mixture of RNA bacteriophages isolated from municipal wastewater was used to control and remove biofilms. At the concentrations of 400 and 4 × 107 PFU/mL, the phages inhibited Pseudomonas aeruginosa biofilm formation by 45 ± 15% and 73 ± 8%, respectively. At the concentrations of 6,000 and 6 × 107 PFU/mL, the phages removed 45 ± 9% and 75 ± 5% of pre‐existing P. aeruginosa biofilms, respectively. Chlorine reduced biofilm growth by 86 ± 3% at the concentration of 210 mg/L, but it did not remove pre‐existing biofilms. However, a combination of phages (3 × 107 PFU/mL) and chlorine at this concentration reduced biofilm growth by 94 ± 2% and removed 88 ± 6% of existing biofilms. In a continuous flow system with continued biofilm growth, a combination of phages (a one‐time treatment at the concentration of 1.9 × 108 PFU/mL for 1 h first) with chlorine removed 97 ± 1% of biofilms after Day 5 while phage and chlorine treatment alone removed 89 ± 1% and 40 ± 5%, respectively. For existing biofilms, a combined use of a lower phage concentration (3.8 × 105 PFU/mL) and chlorination with a shorter time duration (12 h) followed by continuous water flushing removed 96 ± 1% of biofilms in less than 2 days. Laser scanning confocal microscopy supplemented with electron microscopy indicated that the combination treatment resulted in biofilms with lowest cell density and viability. These results suggest that the combination treatment of phages and chlorine is a promising method to control and remove bacterial biofilms from various surfaces. Biotechnol. Bioeng. 2013; 110: 286–295. © 2012 Wiley Periodicals, Inc.  相似文献   

16.
Deep microbial biofilms are a major problem in many industrial, environmental, and medical settings. Novel approaches are needed to understand the structure and metabolism of these biofilms. Two-photon excitation microscopy (TPE) and conventional confocal laser scanning microscopy (CLSM) were compared quantitatively for the ability to visualize bacteria within deep in vitro biofilms. pH gradients within these biofilms were determined by fluorescence lifetime imaging, together with TPE. A constant-depth film fermentor (CDFF) was inoculated for 8 h at 50 ml. h(-1) with a defined mixed culture of 10 species of bacteria grown in continuous culture. Biofilms of fixed depths were developed in the CDFF for 10 or 11 days. The microbial compositions of the biofilms were determined by using viable counts on selective and nonselective agar media; diverse mixed-culture biofilms developed, including aerobic, facultative, and anaerobic species. TPE was able to record images four times deeper than CLSM. Importantly, in contrast to CLSM images, TPE images recorded deep within the biofilm showed no loss of contrast. The pH within the biofilms was measured directly by means of fluorescence lifetime imaging; the fluorescence decay of carboxyfluorescein was correlated with biofilm pH and was used to construct a calibration curve. pH gradients were detectable, in both the lateral and axial directions, in steady-state biofilms. When biofilms were overlaid with 14 mM sucrose for 1 h, distinct pH gradients developed. Microcolonies with pH values of below pH 3.0 were visible, in some cases adjacent to areas with a much higher pH (>5.0). TPE allowed resolution of images at significantly greater depths (as deep as 140 microm) than were possible with CLSM. Fluorescence lifetime imaging allowed the in situ, real-time imaging of pH and the detection of sharp gradients of pH within microbial biofilms.  相似文献   

17.
18.
19.
AIMS: The purpose of this study was to compare the efficacy, in terms of bacterial biofilm penetration and killing, of alkaline hypochlorite (pH 11) and chlorosulfamate (pH 5.5) formulations. METHODS AND RESULTS: Two species biofilms of Pseudomonas aeruginosa and Klebsiella pneumoniae were grown by flowing a dilute medium over inclined stainless steel slides for 6 d. Microelectrode technology was used to measure concentration profiles of active chlorine species within the biofilms in response to treatment at a concentration of 1000 mg total chlorine l(-1). Chlorosulfamate formulations penetrated biofilms faster than did hypochlorite. The mean penetration time into approximately 1 mm-thick biofilms for chlorosulfamate (6 min) was only one-eighth as long as for the same concentration of hypochlorite (48 min). Chloride ion penetrated biofilms rapidly (5 min) with an effective diffusion coefficient in the biofilm that was close to the value for chloride in water. Biofilm bacteria were highly resistant to killing by both antimicrobial agents. Biofilms challenged with 1000 mg l(-1) alkaline hypochlorite or chlorosulfamate for 1 h experienced 0.85 and 1.3 log reductions in viable cell numbers, respectively. Similar treatment reduced viable numbers of planktonic bacteria to non-detectable levels (log reduction greater than 6) within 60 s. Aged planktonic and resuspended laboratory biofilm bacteria were just as susceptible to hypochlorite as fresh planktonic cells. CONCLUSION: Chlorosulfamate transport into biofilm was not retarded whereas hypochlorite transport clearly was retarded. Superior penetration by chlorosulfamate was hypothesized to be due to its lower capacity for reaction with constituents of the biofilm. Poor biofilm killing despite direct measurement of effective physical penetration of the antimicrobial agent into the biofilm demonstrates that bacteria in the biofilm are protected by some mechanism other than simple physical shielding by the biofilm matrix. SIGNIFICANCE AND IMPACT OF THE STUDY: This study lends support to the theory that the penetration of antimicrobial agents into microbial biofilms is controlled by the reactivity of the antimicrobial agent with biofilm components. The finding that chlorine-based biocides can penetrate, but fail to kill, bacteria in biofilms should motivate the search for other mechanisms of protection from killing by antimicrobial agents in biofilms.  相似文献   

20.
A concentric cylinder reactor (CCR) is described that enables the steady-state kinetics of microbial biofilms to be evaluated under conditions of constant nutrient flow and variable shear-stress. The reactor has been used to evaluate the influence of fluid dynamic shear on the extent and mode of detachment of bacteria from biofilms. Using a food factory isolate of Pseudomonas aeruginosa, a general increase in the overall growth rate and detachment of the biofilms (cfu cm−2 min−1) with time was shown for each biofilm, regardless of the prevailing shear. As the shear rate was increased beyond 0.123 ms−1, populations tended toward a pseudo steady-state. Sudden changes in shear force, however, caused dramatic changes in the productivity of steady-state populations. The CCR provides an effective means of testing disinfectant activity, particularly for clean-in-place situations, and allows for an examination of the residual effects of a cleansing programme on a treated surface for three different chemical classes of disinfectant. Utilisation of the CCR would, therefore, provide enhanced ability to determine the efficacy and efficiency of chemical products for use in sanitation protocols. Journal of Industrial Microbiology & Biotechnology (2000) 25, 235–241. Received 09 February 2000/ Accepted in revised form 27 June 2000  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号