首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on the expected effect of the addition of gadolinium on the dose absorbed by the alanine molecules inside the pellets. These results are compared with the experimental values, and the agreement is discussed.  相似文献   

2.
Alanine EPR dosimetry has been applied successfully when measuring intermediate and high radiation doses. Although the performance of alanine dosimetry is being improved, the sensitivity of the material is too low for a fast and simple low- dose determination. Here we present the results using ammonium formate as an EPR dosimeter material. Ammonium formate is seven times more sensitive than alanine, using spectrometer settings optimized for the latter. Deuterated ammonium formate is found to be more than eight times more sensitive than alanine. Analysis of signal stability with time shows that the ammonium formate signal is stable by 5 min after irradiation and that no change in signal intensity is found during 8 days. The atomic composition of ammonium formate is closer to that of tissue than alanine, and thus the energy dependence is smaller than that of alanine at photon energies below 200 keV. Power saturation studies indicate that the energy transfer between the spins and the lattice is fast in ammonium formate, which gives the possibility of using high microwave power without saturation to further increase the sensitivity. These results suggest that ammonium formate has some important properties required of an EPR dosimeter for applications in dosimetry in the dose range typical for radiation therapy.  相似文献   

3.
Some recent neutron capture therapy research has focused on using compounds containing the element gadolinium, which produces internal conversion and Auger cascade electrons. The low-energy, short-range Auger electrons are absorbed locally and increase cell killing dramatically as the gadolinium compounds are introduced into the cell nucleus and bind to the DNA. Detailed electron and photon spectra are needed for biophysical modeling and Monte Carlo calculations of damage to DNA. This paper presents calculated electron and photon spectra for three cases: thermal neutron absorption by (157)Gd, the beta-particle decay of (159)Gd, and the K-shell photoelectric event in gadolinium. The Monte Carlo sampling of atomic and nuclear transitions for each of the three cases was used to calculate a large number of representative decays. The sampled decays were used to determine average emissions and energy deposited in small spheres of tissue. The kinetic energy nuclear recoil from gamma-ray and electron emissions was calculated and found to be more than 10 eV for 26% of all (157)Gd neutron capture reactions.  相似文献   

4.
EPR dosimetry is characterized by its non-destructive read-out and the possibility of dose archival. Here, taurine is proposed as a radiation dosimeter using EPR spectroscopy. The EPR spectrum of taurine was studied and assigned, and changes in the taurine EPR spectrum as a result of the change in both modulation amplitude and microwave power were quantified. For gamma radiation, the energy absorption coefficient and the collision mass stopping power of taurine were compared to the corresponding values of soft tissue and alanine, in addition to calculation of effective atomic numbers. The response of taurine to gamma radiation doses in the range from 0.1 to 50 kGy was investigated, as well as that in the range from 1.0 to 20.0 Gy using numerically enhanced EPR taurine spectra. Both response curves showed a linear behavior. In addition, the time dependence of radiation-induced radicals was studied for short (during the first 6 h after irradiation) and long (during about 3 months after irradiation) time periods, and a reasonable degree of stability of the taurine radicals was observed. It is concluded that taurine is a promising dosimeter, which is characterized by its simple spectrum, radical stability, and wide range of linear response to gamma radiation.  相似文献   

5.
Human melanoma regression by single thermal neutron capture therapy (NCT) using melanoma-seeking 10B compounds has been achieved. Since 1972, the aim of my team has been to synthesize tumor-seeking 10B-compounds possessing selective affinity for specific metabolic activity of the target cancer cells. Once the melanoma takes up these 10B compounds, thermal neutrons, which cause insignificant cell damage, are easily absorbed by nonradioactive 10B, inducing the 10B(n, alpha)7Li reaction and releasing the high LET particles to 14 mu melanoma cell diameter, destroying the tumor without damaging surrounding tissue. Radiobiological and preclinical studies culminated in the first successful human NCT treatment, with no recurrence of the treated melanoma since July, 1987.  相似文献   

6.
Neutron capture therapy (NCT) research encompasses a wide range of preclinical and clinical studies needed to develop this promising but complex cancer treatment. Many specialized facilities and capabilities including thermal and epithermal neutron irradiation facilities, boron analysis, specialized mixed-field dosimetry, animal care facilities and protocols, cell culture laboratories, and, for human clinical studies, licenses and review board approvals are required for NCT research. Such infrastructure is essential, but much of it is not readily available within the community. This is especially true for neutron irradiation facilities, which often require significant development and capital investment too expensive to duplicate at each site performing NCT research. To meet this need, the NCT group at the Massachusetts Institute of Technology (MIT) has established a User Center for NCT researchers that is already being accessed successfully by various groups. This paper describes the facilities, capabilities and other resources available at MIT and how the NCT research community can access them.  相似文献   

7.
PurposeWe simulated the effect of patient displacement on organ doses in boron neutron capture therapy (BNCT). In addition, we developed a faster calculation algorithm (NCT high-speed) to simulate irradiation more efficiently.MethodsWe simulated dose evaluation for the standard irradiation position (reference position) using a head phantom. Cases were assumed where the patient body is shifted in lateral directions compared to the reference position, as well as in the direction away from the irradiation aperture.For three groups of neutron (thermal, epithermal, and fast), flux distribution using NCT high-speed with a voxelized homogeneous phantom was calculated. The three groups of neutron fluxes were calculated for the same conditions with Monte Carlo code. These calculated results were compared.ResultsIn the evaluations of body movements, there were no significant differences even with shifting up to 9 mm in the lateral directions. However, the dose decreased by about 10% with shifts of 9 mm in a direction away from the irradiation aperture.When comparing both calculations in the phantom surface up to 3 cm, the maximum differences between the fluxes calculated by NCT high-speed with those calculated by Monte Carlo code for thermal neutrons and epithermal neutrons were 10% and 18%, respectively. The time required for NCT high-speed code was about 1/10th compared to Monte Carlo calculation.ConclusionsIn the evaluation, the longitudinal displacement has a considerable effect on the organ doses.We also achieved faster calculation of depth distribution of thermal neutron flux using NCT high-speed calculation code.  相似文献   

8.
(sup14)C-synthetic lignin mineralization by the basidiomycete Ceriporiopsis subvermispora occurs at the highest rate (about 30% after 29 days) in liquid cultures containing 1% glucose and a growth-limiting amount (1 mM) of ammonium tartrate. The titers of manganese peroxidase (MnP) and laccase are lower in these cultures than in cultures containing 1% glucose and 10 mM ammonium tartrate, where the extent of lignin mineralization in the same period is only about 15%. The inverse correlation between enzyme activity and lignin mineralization is also observed when ammonium tartrate is replaced by ammonium chloride or Casamino Acids as the source of nitrogen. This phenomenon can be explained by a gradual increase in the pH of the medium that takes place only in the cultures with high nitrogen concentrations. Supporting this finding, when cultures with 1 mM ammonium tartrate were grown at different pHs, (sup14)CO(inf2) evolved more rapidly from those with pH values near the optimum for MnP activity. On the other hand, (sup14)CO(inf2) evolution from cultures containing 1% glucose supplemented with 1 mM ammonium tartrate plus 9 mM sodium tartrate was as low as that from cultures with a high ammonium tartrate concentration. Since the changes in the pH of these cultures were not as pronounced as those in cultures containing high nitrogen concentrations, tartrate itself may also be contributing to limit the extent of lignin mineralization. Considering that pH instability seems to constitute a common feature of fungal cultures, precautions must be taken to avoid underestimation of their ligninolytic efficiencies.  相似文献   

9.
PurposeIn previous studies, methylthymol-blue and benzoic acid have been introduced as a diffuser limiter and sensitivity enhancer in the gel dosimeter composition, respectively. This work focused on analyzing a formulation of the Fricke gel dosimeter consisting of methylthymol-blue and benzoic acid through magnetic resonance imaging.MethodsThe gel dosimeter samples were irradiated using 6, 10, and 15 MV photons with different levels of doses and read using a 1.5 T scanner in order to evaluate the dose–response sensitivity and to study the effect of benzoic acid concentration, diffusion coefficient and temperature and to determine the temporal stability of the gel dosimeter.ResultsInspection of radiological properties revealed that this gel dosimeter can be considered as a tissue equivalent medium. Within the dose range 0 to 1000 cGy, the R1 sensitivity and R2 sensitivity of the gel dosimeter equaled 0.058 ± 0.003 and 0.092 ± 0.004 s−1Gy−1, respectively. The diffusion coefficient was less than 0.85 ± 0.02mm2h−1 for doses higher than 200 cGy. In addition, by changing the temperature from 15C to 25, the R1 sensitivity and R2 sensitivity decreased about 5 and 11%, respectively. Further, no significant energy and dose rate dependence were observed over photon energies of 6, 10, and 15 MV and over the range 65 to 525 cGy min−1.ConclusionsBased on our observation, the ferrous benzoic acid methylthymol-blue gel dosimeter can be suggested to measure the dose distribution. Further analysis is required to clarify its performance in clinical situations.  相似文献   

10.
PurposeA new polymer gel dosimeter recipe was investigated that may be more suitable for widespread applications than polyacrylamide gel dosimeters, since the extremely toxic acrylamide has been replaced with the less harmful monomer 2-Acrylamido 2-Methyl Propane Sulfonic acid (AMPS).MethodsThe new formulation was named PAMPSGAT. The MRI response (R2) of the dosimeters was analyzed for conditions of varying dose, dose rate, and temperature during scanning. Radiological properties of the PAMPSGAT polymer gel dosimeter were investigated.ResultsThe dose-response (R2) of AMPS/Bis appears to be linear over a dose range 10–40 Gy. The percentage of difference between the R2 values for imaging at 15 °C and MRI room temperature is about 4.6% for vial with 40 Gy absorbed dose which decreased to less than 1% for imaging at 20 °C. The percentage difference of Zeff of PAMPSGAT gel and soft tissue was less than 1% in the practical energy range (100 KeV–100 MeV). The electron density of the PAMPSGAT polymer gel was 2.9% higher than that of muscle. Results showed that the sensitivity of PAMPSGAT polymer gel dosimeter irradiated by 60Co (energy = 1.25 MeV) is about 27.7% higher than that of irradiated using a 6 MeV Linac system.ConclusionsTemperature during MRI scanning has a small effect on the R2 response of the PAMPSGAT polymer gel dosimeter. Results confirmed tissue equivalency of the PAMPSGAT polymer gel dosimeter in most practical energy range. The PAMPSGAT polymer gel dosimeter response depends on energy and dose rate.  相似文献   

11.
In this paper we present an investigation of the electron spin resonance (ESR) line shape of ammonium tartrate (AT) dosimeters exposed to radiation with different linear energy transfer (LET). We exposed our dosimeters to gamma-ray photons ((60)Co), 7 MeV and 14 MeV initial energy electrons, and 19.3 MeV initial energy protons. The differences in the power saturation behavior of ESR spectra of AT irradiated with photons, electrons and protons could be correlated to the effective LET of the radiation beams. We analyzed the behavior of peak-to-peak amplitude as a function of microwave power, and we developed a fitting procedure that permits us to obtain the dependence of the homogeneity parameter of the line shape on the LET of the radiation using the Castner saturation theory. This simple procedure allows us to distinguish the LET of the radiation beam.  相似文献   

12.
Suillus and Boletinus were studied using Ohta medium. In media with glucose or trehalose, all tested strains grew well. With mannose and cellobiose, strains generally grew well, except for one strain of Suillus. Utilization of dextrin and soluble starch differed with each strain, and that of sucrose and glycerol was low for all strains. Utilization of four amino acids, arginine, glutamic acid, aspartic acid, and alanine, was similar to that of ammonium tartrate for Suillus strains, but mycelial growth with amino acids was clearly lower than with ammonium tartrate for the Boletinus strain. The effect of glucose and ammonium tartrate concentrations for nine strains of the genera Suillus and Boletinus was studied with ranges for glucose of 1–100 and 200g/l, respectively, and for ammonium tartrate of 0.2–5 and 20g/l, respectively. Six strains showed maximal growth at a glucose concentration greater than 25g/l, and one strain showed maximal growth at 70g/l. The results indicate that these fungi are adapted to relatively high concentrations of carbon sources. In general, glucose concentration at mycelial growth maximum decreased as ammonium tartrate concentration increased, and at higher concentrations of glucose, mycelial growth decreased more rapidly in higher concentrations of ammonium tartrate.  相似文献   

13.
Currently, neutron capture therapy is a promising cancer treatment. This method is based on the reaction of thermal neutron capture by some nonradioactive elements (e.g., Gd157), which results in the sub-sequent emission of electrons and gamma rays. An effective instrument for delivering gadolinium into tumor tissue are “rigid” nanostructures (NSs) based on double-stranded DNA complexes with gadolinium (NS-Gd). The local concentration of Gd in these nanostructures may reach 40%. To optimize the process of neutron capture therapy, it is very important to investigate possible mechanisms of the penetration of NS-Gd particles into tumor cells. In this work, the dynamics of interaction between NS-Gd and cultivated Chinese hamster ovary cells (CHO) was studied by confocal and electron microscopy. NS-Gd were shown to be able to enter CHO cells. This process started after about 1 h of incubation. After 6 h, NS-Gd particles were detected in almost all cells. A further increase in the incubation time did not lead to significant changes in cell morphology, although the amount of NS-Gd inside cells continued to increase. The plasma membranes of the cells remained intact. Once entering the cells, NS-Gd particles remained there for a long time. The data show that NS-Gd has relatively low toxicity and suggest that the presence of NS-Gd in tumor cells does not prevent their division. The data are important for improving the efficiency of the method of neutron-capture therapy.  相似文献   

14.
Summary When detailed neutron energy spectrum data are lacking for a mixed field of neutrons and photons, it is permissible when estimating the dose equivalent to assume that the quality factor for the neutrons is 10. With this assumption, it is shown that the responses of a tissue-equivalent ionization chamber and a Geiger-Müller dosimeter can be used to obtain an acceptable approximation of the dose equivalent in the mixed field without requiring precise knowledge of the relative neutron sensitivity of the Geiger-Müller dosimeter.This investigation was supported by Contract EP-78-S-02-4733 from the Department of Energy to the Radiological Research Laboratory/Department of Radiology and by Grant No. CA13696 to the Cancer Center/Institute of Cancer Research, awarded by National Cancer Institute, DHEW  相似文献   

15.
Induction of DNA double-strand breaks by 157Gd neutron capture   总被引:3,自引:0,他引:3  
The rationale of boron (10B) neutron capture therapy (BNCT) is based on the high thermal neutron capture cross section of 10B and the limited maximum range (about one cell diameter) of the high LET fission products of the boron neutron capture (NC) reaction. The resulting radiochemical damage is confined to the cell containing the BNC reaction. Although other nuclides have higher thermal neutron capture cross sections than 10B, NC by such nuclides results in the emission of highly penetrating gamma rays. However, gadolinium-157 (157Gd) n-gamma reaction is also accompanied by some internal conversion and, by implication, Auger electron emission. Irradiation of Gd3+-DNA complexes with thermal neutrons results in the induction of DNA double-strand (ds) breaks, but the effect is largely abrogated in the presence of EDTA. Thus, by analogy with the effects of decay of Auger electron-emitting isotopes such as 125I, the Gd NC event must take place in the close proximity of DNA in order to induce a DNA ds break. It is proposed that 157Gd-DNA ligands therefore have potential in NCT. The thermal neutron capture cross section of 157Gd, a nonradioactive isotope, is more than 50 times that of 10B.  相似文献   

16.
During microaerophilic growth of magnetic spirillum MS-1 on tartrate and nitrate, a maximal cell density was obtained at an initial oxygen partial pressure of 17 Pa. A transient accumulation of nitrous oxide and a 1:2 (mol/mol) stoichiometry between tartrate oxidation and nitrate reduction were observed, indicating that the organism carried out a respiratory type of metabolism.  相似文献   

17.
On the basis of recent recommendations on soft biotissue composition and data concerning value of specific neutron kerma for a number of element atoms within the energy from thermal one to 29 MeV obtained were the values of electron density, effective atomic number and specific kerma of neutrons for soft biotissue and ferrosulphate dosimeter sensitized by benzoic acid. The data are proposed for practical use in radiobiological experiments.  相似文献   

18.
This paper discusses the clinical applications of electron spin resonance (ESR) dosimetry focusing on the ESR/alanine system. A review of few past studies in this area is presented offering a critical overview of the challenges and opportunities for extending this system into clinical applications. Alanine/ESR dosimetry fulfills many of the required properties for several clinical applications such as water-equivalent composition, independence of the sensitivity for the energy range used in therapy and high precision. Improvements in sensitivity and the development of minidosimeters coupled with the use of a spectrometer of higher microwave frequency expanded the possibilities for clinical applications to the new modalities of radiotherapy (intensity-modulated radiation therapy and radiosurgery) and to the detection of low doses such as those present in some radiological image procedures.  相似文献   

19.
To investigate glucagon (IRG) and insulin (IRI) responses to alanine infusion in obesity and to assess the effect of body weight reduction with respect to hormonal balance, we compared six obese subjects with nine normal weight controls. None of the subjects were diabetic by OGTT criteria. Plasma IRI and IRG were measured following IV alanine at a rate of 0.1 g/kg over a period of 2 min. Our obese subjects had an increase in IRG response to alanine, which was due to decreased suppression of alpha-cell function due to insulin resistance. Weight reduction via calorie restriction reduced insulin demand, resulting in reduced plasma IRI by restoring beta-cell function, and the IRG response was paradoxically decreased as compared with that before weight loss. It is conceivable that improvements in insulin sensitivity after body weight reduction may re-establish the normalization of pancreatic beta-cell function and the insulin-induced inhibition of IRG secretion. Our obese subjects were characterized by decreased IRG secretion which was reflected in a change in body weight reduction.  相似文献   

20.
For the boron neutron capture therapy (NCT) of deep-seated metastatic melanoma, an epithermal (up to a few keV energy) neutron beam from a reactor horizontal facility could be useful if the inherent contamination from fast neutrons and gamma rays could be minimised. Calculations for ANSTO's 10 MW research reactor HIFAR have shown that, even though a filter material such as AlF3 attenuates the fast neutron dose, the beam quality improvement is counteracted by a relative increase in the gamma dose because of the gammas arising from neutron captures in the filter material, particularly the aluminium. The aluminium gammas, most of which arise from thermal neutron capture, are hard and cannot be attenuated by lead or bismuth without comparable attenuation of the epithermal neutron flux. Addition of an absorber such as 6Li to the AlF3 filter was investigated as a means of reducing the hard gamma dose, but the improvement in beam quality was small and at considerable cost to dose intensity. Dose characteristics calculations confirmed the superiority of a tangential beam over a radial beam with better results from an unfiltered tangential beam than from an AlF3 filter in a radial beam. This study showed conclusively that assessments of filter assemblies based on the effect of individual components on either the neutron or gamma dose in isolation are inadequate. In assessing any epithermal neutron filter, thermal neutron shield, and gamma shield combination, the total effect of each on the neutron, gamma, and boron-10 dose must be considered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号