首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Conventional flow cytometry using scattering and fluorescent detection methods has been a fundamental tool of biological discoveries for many years. Invasive extraction of cells from a living organism, however, may lead to changes in cell properties and prevents the long-term study of cells in their native environment. Here, we summarize recent advances of new generation flow cytometry for in vivo noninvasive label-free or targeted detection of cells in blood, lymph, bone, cerebral and plant vasculatures using photoacoustic (PA) detection techniques, multispectral high-pulse-repetition-rate lasers, tunable ultrasharp (up to 0.8nm) rainbow plasmonic nanoprobes, positive and negative PA contrasts, in vivo magnetic enrichment, time-of-flight cell velocity measurement, PA spectral analysis, and integration of PA, photothermal (PT), fluorescent, and Raman methods. Unique applications of this tool are reviewed with a focus on ultrasensitive detection of normal blood cells at different functional states (e.g., apoptotic and necrotic) and rare abnormal cells including circulating tumor cells (CTCs), cancer stem cells, pathogens, clots, sickle cells as well as pharmokinetics of nanoparticles, dyes, microbubbles and drug nanocarriers. Using this tool we discovered that palpation, biopsy, or surgery can enhance CTC release from primary tumors, increasing the risk of metastasis. The novel fluctuation flow cytometry provided the opportunity for the dynamic study of blood rheology including red blood cell aggregation and clot formation in different medical conditions (e.g., blood disorders, cancer, or surgery). Theranostics, as a combination of PA diagnosis and PT nanobubble-amplified multiplex therapy, was used for eradication of CTCs, purging of infected blood, and thrombolysis of clots using PA guidance to control therapy efficiency. In vivo flow cytometry using a portable fiber-based devices can provide a breakthrough platform for early diagnosis of cancer, infection and cardiovascular disorders with a potential to inhibit, if not prevent, metastasis, sepsis, and strokes or heart attack by well-timed personalized therapy.  相似文献   

2.
Deep vein thrombosis (DVT) is a disorder when a blood clot (thrombus) is formed in one of the deep veins. These clots detach from the original sites and circulate in the blood stream at high velocities. Diagnosing these blood clots at an early stage is necessary to decide the treatment strategy. For label-free, in vivo, and real-time detection, high framerate photoacoustic imaging can be used. In this work, a dual modal clinical ultrasound and photoacoustic (PA) system is used for the high framerate PA imaging of circulating blood clots in blood at linear velocities up to 107 cm/sec. Blood clot had 1.4 times higher signal-to-noise ratio (SNR) in the static mode and 1.3 times higher SNR compared to blood PA signal in the flow experiments. This work demonstrates that fast-moving circulating blood clots are easy to recognize against the background PA signal and may aid in early diagnosis.  相似文献   

3.
Alterations of blood rheology (hemorheology) are important for the early diagnosis, prognosis, and prevention of many diseases, including myocardial infarction, stroke, sickle cell anemia, thromboembolism, trauma, inflammation, and malignancy. However, real-time in vivo assessment of multiple hemorheological parameters over long periods of time has not been reported. Here, we review the capabilities of label-free photoacoustic (PA) and photothermal (PT) flow cytometry for dynamic monitoring of hemorhelogical parameters in vivo which we refer to as photoacoustic and photothermal blood rheology. Using phenomenological models, we analyze correlations between both PT and PA signal characteristics in the dynamic modes and following determinants of blood rheology: red blood cell (RBC) aggregation, deformability, shape (e.g., as in sickle cells), intracellular hemoglobin distribution, individual cell velocity, hematocrit, and likely shear rate. We present ex vivo and in vivo experimental verifications involving high-speed PT imaging of RBCs, identification of sickle cells in a mouse model of human sickle cell disease and in vivo monitoring of complex hemorheological changes (e.g., RBC deformability, hematocrit and RBC aggregation). The multi-parameter platform that integrates PT, PA, and conventional optical techniques has potential for translation to clinical applications using safe, portable, laser-based medical devices for point-of-care screening of disease progression and therapy efficiency.  相似文献   

4.
In vivo photoacoustic (PA) and fluorescence flow cytometry were previously applied separately using pulsed and continuous wave lasers respectively, and positive contrast detection mode only. This paper introduces a real‐time integration of both techniques with positive and negative contrast modes using only pulsed lasers. Various applications of this new tool are summarized, including detection of liposomes loaded with Alexa‐660 dye, red blood cells labeled with Indocyanine Green, B16F10 melanoma cells co‐expressing melanin and green fluorescent protein (GFP), C8161‐GFP melanoma cells targeted by magnetic nanoparticles, MTLn3 adenocarcinoma cells expressing novel near‐infrared iRFP protein, and quantum dot‐carbon nanotube conjugates. Negative contrast flow cytometry provided label‐free detection of low absorbing or weakly fluorescent cells in blood absorption and autofluorescence background, respectively. The use of pulsed laser for time‐resolved discrimination of objects with long fluorescence lifetime (e.g., quantum dots) from shorter autofluorescence background (e.g., blood plasma) is also highlighted in this paper. The supplementary nature of PA and fluorescence detection increased the versatility of the integrated method for simultaneous detection of probes and cells having various absorbing and fluorescent properties, and provided verification of PA data using a more established fluorescence based technique. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

5.
BACKGROUND: Photothermal (PT) cytometry has recently demonstrated great potential for the label-free detection of nonfluorescent cells under static conditions. The goal of our investigation was to expand this technique to the detection of flowing cells in vitro. METHODS: Cells in flow were irradiated with short, tunable laser pulses (420-2,300 nm, 8 ns), and the absorbed energy was detected by monitoring of the temperature-dependent variations in the refractive index in the cells with a second, collinear probe beam in two modes: (a) PT imaging of single cells with a pulsed probe beam (639 nm, 13 ns) and (b) thermolens monitoring of the integral PT responses from individual cells as whole with a continuous-wave probe beam (633 nm, 2 mW). RESULTS: PT flow cytometry at the current speed of analysis of 10 cell/s, with the capability to image selected cells of interest flowing at velocities up to 2 m/s, demonstrated the capability for (a) label-free detection of flowing single cells (e.g., blood and cancer cells) on the basis of the differences in their endogenous absorption properties, (b) identification of cells labeled with gold nanoparticles, (c) rapid cell viability testing, (d) aggregation immunoassay, and (e) optimization of selective nanophotothermolysis. CONCLUSIONS: PT cytometry can be extended to the study of cells in flow. This new technique increases the speed of cell analysis approximately 10(2) times over that of conventional PT technique, with the potential to achieve a rate of 10(4)-10(5) cells/s in specific PT applications, which has previously been realized only with cells under static conditions.  相似文献   

6.
Fibrinolytic therapy is a proven approach for achieving reperfusion of occluded coronary arteries during myocardial infarction, resulting in reduced mortality and preservation of ventricular function. The amount of myocardial muscle loss is proportional to the duration of ischemia. Bleeding complications are not infrequent. Adjuvant therapy by ultrasound might enhance the rate of fibrinolysis and reduce the concentrations of lytic agents required to achieve an equivalent degree of clot lysis. Noninvasive ultrasound at low intensities and high frequencies, parameters that potentially could be applied and tolerated in vivo, have been proven to significantly accelerate the rate of fibrinolysis in both in vitro and in vivo models, in pure fibrin as well as whole blood clots. Such enhancement is not drug-specific. These effects were achieved by nonthermal mechanism. Ultrasound exposure did not cause mechanical fragmentation of the clot, did not alter the size of plasmatic derivates and degradation products. Ultrasound caused increased flow rate through thrombi, probably by cavitation-induced changes in fibrin ultrastructure; disaggregation of uncrosslinked fibrin fibers into smaller fibers has been shown. This resulted in increased transport of the lytic agent into the clot, alteration of binding affinity and increased maximum binding. Presence of echo-contrast agent induced further acceleration of thrombolysis by ultrasound.  相似文献   

7.
In‐vivo multicolor photoacoustic (PA) flow cytometry for ultrasensitive molecular detection of the CD44+ circulating tumor cells (CTCs) is demonstrated on a mouse model of human breast cancer. Targeting of CTCs with stem‐like phenotype, which are naturally shed from parent tumors, was performed with functionalized gold and magnetic nanoparticles. Results in vivo were verified in vitro with a multifunctional microscope, which integrates PA, photothermal (PT), fluorescent and transmission modules. Magnet‐induced clustering of magnetic nanoparticles in individual cells significantly amplified PT and PA signals. The novel noninvasive platform, which integrates multispectral PA detection and PT therapy with a potential for multiplex targeting of many cancer biomarkers using multicolor nanoparticles, may prospectively solve grand challenges in cancer research for diagnosis and purging of undetectable yet tumor‐initiating cells in circulation before they form metastasis. (© 2009 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

8.
Recently, photoacoustic (PA) flow cytometry (PAFC) has been developed for in vivo detection of circulating tumor cells and bacteria targeted by nanoparticles. Here, we propose multispectral PAFC with multiple dyes having distinctive absorption spectra as multicolor PA contrast agents. As a first step of our proof-of-concept, we characterized high-speed PAFC capability to monitor the clearance of three dyes (Indocyanine Green [ICG], Methylene Blue [MB], and Trypan Blue [TB]) in an animal model in vivo and in real time. We observed strong dynamic PA signal fluctuations, which can be associated with interactions of dyes with circulating blood cells and plasma proteins. PAFC demonstrated enumeration of circulating red and white blood cells labeled with ICG and MB, respectively, and detection of rare dead cells uptaking TB directly in bloodstream. The possibility for accurate measurements of various dye concentrations including Crystal Violet and Brilliant Green were verified in vitro using complementary to PAFC photothermal (PT) technique and spectrophotometry under batch and flow conditions. We further analyze the potential of integrated PAFC/PT spectroscopy with multiple dyes for rapid and accurate measurements of circulating blood volume without a priori information on hemoglobin content, which is impossible with existing optical techniques. This is important in many medical conditions including surgery and trauma with extensive blood loss, rapid fluid administration, and transfusion of red blood cells. The potential for developing a robust clinical PAFC prototype that is safe for human, and its applications for studying the liver function are further highlighted.  相似文献   

9.
The success of clot thrombolysis very much depends on efficient clot permeation with blood plasma carrying the thrombolytic agent. In this paper clot permeation was studied by dynamic magnetic resonance imaging (MRI) on artificial non-occlusive blood clots inserted in an artificial circulation system filled with blood plasma to which an MRI contrast agent was added. The MRI results revealed that clot permeation is much faster and more efficient at the entrance of the flow channel across the clot. Clot permeation with fluid was simulated numerically as well. The simulation was based on numerical solution of Navier-Stokes equations for the flow in the channel and within the clot. The clot was considered as a porous material with known permeability and porosity. Based on the calculated velocity profiles, concentration profiles of fluid in the clot were modelled. These agreed well with the MRI results. The presented model of clot permeation with fluid may also serve as a useful extension to numerical modelling of dissolution of non-occlusive blood clots during thrombolytic therapy.  相似文献   

10.

The ability of a blood clot to modulate blood flow is determined by the clot’s resistance, which depends on its structural features. For a flow with arterial shear, we investigated the characteristic patterns relating to clot shape, size, and composition on the one hand, and its viscous resistance, intraclot axial flow velocity, and shear distributions on the other. We used microfluidic technology to measure the kinetics of platelet, thrombin, and fibrin accumulation at a thrombogenic surface coated with collagen and tissue factor (TF), the key clot-formation trigger. We subsequently utilized the obtained data to perform additional calibration and validation of a detailed computational fluid dynamics model of spatial clot growth under flow. We then ran model simulations to gain insights into the resistance of clots formed under our experimental conditions. We found that increased thrombogenic surface length and TF surface density enhanced the bulk thrombin and fibrin generation in a nonadditive, synergistic way. The height of the platelet deposition domain—and, therefore, clot occlusivity—was rather robust to thrombogenic surface length and TF density variations, but consistently increased with time. Clot viscous resistance was non-uniform and tended to be higher in the fibrin-rich, inner “core” region of the clot. Interestingly, despite intraclot structure and viscous resistance variations, intraclot flow velocity variations were minor compared to the abrupt decrease in flow velocity around the platelet deposition region. Our results shed new light on the connection between the structure of clots under arterial shear and spatiotemporal variations in their resistance to flow.

  相似文献   

11.
目的:利用大鼠自体血栓,在开放翼腭动脉( pterygopalatine artery,PPA)的情况下堵塞其大脑中动脉,造成大脑中动脉远端供血区的脑梗死模型。方法开放PPA,结扎颈外动脉( external carotid artery,ECA),将栓子通过颈总动脉(common carotid artery,CCA)血流将栓子冲大脑中动脉(middle cerebral artery,MCA)远端,造成梗死模型,按Bederson评分对其神经功能进行评分,TTC染色确定梗死体积。结果两手术组模型比较,评分均升高,且出现白色梗死区,经统计检测分析无明显差异。结论开放PPA大鼠自体血栓制造脑梗死模型可缩短手术时间,降低死亡率。  相似文献   

12.
The structure and growth of a blood clot depend on the localization of tissue factor (TF), which can trigger clotting during the hemostatic process or promote thrombosis when exposed to blood under pathological conditions. We sought to understand how the growth, structure, and mechanical properties of clots under flow are shaped by the simultaneously varying TF surface density and its exposure area. We used an eight-channel microfluidic device equipped with a 20- or 100-μm-long collagen surface patterned with lipidated TF of surface densities ~0.1 and ~2 molecules/μm2. Human whole blood was perfused at venous shear, and clot growth was continually measured. Using our recently developed computational model of clot formation, we performed simulations to gain insights into the clot’s structure and its resistance to blood flow. An increase in TF exposure area resulted not only in accelerated bulk platelet, thrombin, and fibrin accumulation, but also in increased height of the platelet mass and increased clot resistance to flow. Moreover, increasing the TF surface density or exposure area enhanced platelet deposition by approximately twofold, and thrombin and fibrin generation by greater than threefold, thereby increasing both clot size and its viscous resistance. Finally, TF effects on blood flow occlusion were more pronounced for the longer thrombogenic surface than for the shorter one. Our results suggest that TF surface density and its exposure area can independently enhance both the clot’s occlusivity and its resistance to blood flow. These findings provide, to our knowledge, new insights into how TF affects thrombus growth in time and space under flow.  相似文献   

13.
Bacterial infections are a primary cause of morbidity and mortality worldwide. Bacteremia is a particular concern owing to the possibility of septic shock and the development of metastatic infections. Treatment of bacteremia is increasingly compromised by the emergence of antibiotic resistant strains, creating an urgent need for alternative therapy. Here, we introduce a method for in vivo photoacoustic (PA) detection and photothermal (PT) eradication of Staphylococcus aureus in tissue and blood. We show that this method could be applicable for label-free diagnosis and treatment of in the bloodstream using intrinsic near-infrared absorption of endogenous carotenoids with nonlinear PA and PT contrast enhancement. To improve sensitivity and specificity for detection of circulating bacteria cells (CBCs), two-color gold and multilayer magnetic nanoparticles with giant amplifications of PA and PT contrasts were functionalized with an antibody cocktail for molecular targeting of S. aureus surface-associated markers such as protein A and lipoprotein. With a murine model, the utility of this approach was demonstrated for ultrasensitive detection of CBCs with threshold sensitivity as low as 0.5 CBCs/mL, in vivo magnetic enrichment of CBCs, PT eradication of CBCs, and real-time monitoring of therapeutic efficacy by CBC counting. Our PA-PT nano-theranostic platform, which integrates in vivo multiplex targeting, magnetic enrichment, signal amplification, multicolor recognition, and feedback control, could be used as a biological tool to gain insights on dissemination pathways of CBCs, infection progression by bacteria re-seeding, and sepsis development and treatment, and could potentially be feasible in humans, especially using bypass schematic.  相似文献   

14.
Clotting in animals having open or closed circulatory system comprises humoral and cellular mechanisms. Sipunculans are a small phylum of non-segmented marine worms that do not have a true circulatory system. These worms can form a cellular clot without transforming cell-free coelomic fluid into an insoluble mass. The clot may also contribute to immune response by entrapping foreign particles. We evaluated the formation of a cellular clot ex vivo in the sipunculan Themiste petricola after activation through glass contact and sea water, the ability to entrap magnetic beads and non-pathogen cyanobacteria particles within the clot, and the presence of a peptidoglycan recognition protein S (PGRP-S) antigen in cells forming the clot. Our results showed that the clot was formed by homotypic aggregation of large granular leukocytes (LGLs), a subtype of cells found in the coelomic fluid. Aggregated LGLs served to entrap magnetic beads and non-pathogen cyanobacteria particles, and PGRP-S antigen was detected both in non-activated LGLs and in activated homotypic aggregates through immunofluorescence, Western blot and flow cytometry. Cellular clots were found to be positive to Annexin V-FITC labelling. Complete disintegration of cytoplasm with shedding of microparticles, nuclear isolation and degradation were also observed by light microscopy and flow cytometry. In conclusion, cellular clot formation in Themiste petricola may serve both haemostatic and immune functions entailing rapid activation changes in LGLs, entrapment of foreign particles within a homotypic aggregate, and further cell death.  相似文献   

15.
Although adenosine markedly increases fetal pulmonary blood flow, the specific changes in pulmonary trunk (PT), ductus arteriosus (DA), and conduit pulmonary artery (PA) flow interactions that support this increased flow are unknown. To address this issue, seven anesthetized late-gestation fetal sheep were instrumented with PT, DA, and left PA micromanometer catheters and transit-time flow probes. Blood flow profile and wave intensity analyses were performed at baseline and after adenosine infusion to increase PA flow approximately fivefold. With adenosine infusion, DA mean and phasic flows were unchanged, but increases in mean PT (500 ± 256 ml/min, P = 0.002) and the combined left and right PA flow (479 ± 181 ml/min, P < 0.001) were similar (P > 0.7) and related to a larger flow-increasing forward-running compression wave arising from right ventricular (RV) impulsive contraction. Moreover, while the increased PT flow was confined to systole, the rise in PA flow spanned systole (316 ml/min) and diastole (163 ml/min). This elevated PA diastolic flow was accompanied by a 170% greater discharge from a PT and main PA reservoir filled in systole (P < 0.001), but loss of retrograde blood discharge from a conduit PA reservoir that was evident at baseline. These data suggest that 1) an increase in fetal pulmonary blood flow produced by adenosine infusion is primarily supported by a higher PT blood flow (i.e., RV output); 2) about two-thirds of this increased RV output passes into the pulmonary circulation during systole; and 3) the remainder is transiently stored in a central PT and main PA systolic reservoir, from where it discharges into the lungs in diastole.  相似文献   

16.
Studies suggest that patients with deep vein thrombosis and diabetes often have hypercoagulable blood plasma, leading to a higher risk of thromboembolism formation through the rupture of blood clots, which may lead to stroke and death. Despite many advances in the field of blood clot formation and thrombosis, the influence of mechanical properties of fibrin in the formation of thromboembolisms in platelet-poor plasma is poorly understood. In this paper, we combine the concepts of reactive molecular dynamics and coarse-grained molecular modeling to predict the complex network formation of fibrin clots and the branching of fibrin monomers. The 340-kDa fibrinogen molecule was converted into a coarse-grained molecule with nine beads, and using our customized reactive potentials, we simulated the formation and polymerization process of a fibrin clot. The results show that higher concentrations of thrombin result in higher branch-point formation in the fibrin clot structure. Our results also highlight many interesting properties, such as the formation of thicker or thinner fibers depending on the thrombin concentration. To the best of our knowledge, this is the first successful molecular polymerization study of fibrin clots to focus on thrombin concentration.  相似文献   

17.
Fibrin is an extracellular matrix protein that is responsible for maintaining the structural integrity of blood clots. Much research has been done on fibrin in the past years to include the investigation of synthesis, structure-function, and lysis of clots. However, there is still much unknown about the morphological and structural features of clots that ensue from patients with disease. In this research study, experimental techniques are presented that allow for the examination of morphological differences of abnormal clot structures due to diseased states such as diabetes and sickle cell anemia. Our study focuses on the preparation and evaluation of fibrin clots in order to assess morphological differences using various experimental assays and confocal microscopy. In addition, a method is also described that allows for continuous, real-time calculation of lysis rates in fibrin clots. The techniques described herein are important for researchers and clinicians seeking to elucidate comorbid thrombotic pathologies such as myocardial infarctions, ischemic heart disease, and strokes in patients with diabetes or sickle cell disease.  相似文献   

18.
Leeches are amazing animals that can be classified as conditionally poisonous animals since the salivary cocktail they produce is injected directly into the victim, and its components have strictly defined biological purposes, such as preventing blood clot formation. Thrombolytic drugs are mainly aimed at treating newly formed blood clots. Aged clots are stabilized by a large number of isopeptide bonds that prevent the action of thrombolytics. These bonds are destroyed by destabilase, an enzyme of the leech’s salivary glands. Here, we conducted a pilot study to evaluate the feasibility and effectiveness of the use of destabilase in relation to blood clots formed during real pathological processes. We evaluated the isopeptidase activity of destabilase during the formation of a stabilized fibrin clot. We showed that destabilase does not affect the internal and external coagulation cascades. We calculated the dose–response curve and tested the ability of destabilase to destroy isopeptide bonds in natural blood clots. The effect of aged and fresh clots dissolving ability after treatment with destabilase coincided with the morphological characteristics of clots during surgery. Thus, recombinant destabilase can be considered as a potential drug for the treatment of aged clots, which are difficult to treat with known thrombolytics.  相似文献   

19.
Flow cytometry is a well-established, powerful technique for studying cells in artificial flow in vitro. This review covers a new potential application of this technique for studying normal and abnormal cells in their native condition in blood or lymph flow in vivo. Specifically, the capabilities of the label-free photothermal (PT) technique for detecting and imaging cells in the microvessel network of rat mesentery are analyzed from the point of view of overcoming the problems of flow cytometry in vivo. These problems include, among others, the influences of light scattering and absorption in vessel walls and surrounding tissues, instability of cell velocity, and cells numbers and positions in a vessel's cross-section. The potential applications of this new approach in cell biochemistry and medicine are discussed, including molecular imaging; studying the metabolism and pathogenesis of many diseases at a cellular level; and monitoring and quantifying metastatic and apoptotic cells, and/or their responses to therapeutic interventions (e.g., drug or radiation), in natural biological environments.  相似文献   

20.
Although the distribution of average fetal pulmonary trunk (PT) blood flow favors the ductus arteriosus (DA) over the lungs, the phasic aspects of this distribution during systole and diastole are not well understood. Accordingly, flow profile and wave intensity (WI) analyses were performed at baseline and during brief flow increases accompanying an extrasystole (ES) in 10 anesthetized late-gestation fetal sheep instrumented with PT, DA, and left pulmonary artery (PA) micromanometer catheters and transit-time flow probes. At baseline, 83% of mean PT flow crossed the DA and 17% entered the lungs. However, early systolic flow associated with a forward-running compression wave (FCW(is)) was higher in the PA and predominant DA flow only emerged in midsystole when a large PA backward-running compression wave (BCW(ms)), which reduced PA flow, was transmitted into the DA as a forward-running compression wave (FCW(ms)) that increased flow. Subsequent protodiastolic forward DA flow occurring during pulmonary valve closure was associated with substantial retrograde PA flow, but insignificant PT flow. Conversely, forward DA flow in the remainder of diastole occurred with forward PT but near-zero PA flow. These flow and WI patterns, in conjunction with the results of mathematical modeling, suggest that 1) fetal PT flow preferentially passes into the PA during early systole due to a lower PA-than-DA characteristic impedance, while DA flow predominates in mid- and late systole due to flow effects arising from the PA BCW(ms), and 2) forward DA flow is mainly sustained by reversal of PA flow in protodiastole but discharge of a more central reservoir in diastole.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号