首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
Mass spectrometry (MS)-based technology provides label-free localization of molecules in tissue samples. Drugs, proteins, lipids and metabolites can easily be monitored in their environment. Resolution can be achieved down to the cellular level (10-20μm) for conventional matrix-assisted laser desorption/ionization (MALDI) imaging, or even to the subcellular level for more complex technologies such as secondary ionization mass spectrometry (SIMS) imaging. One question remains: are we going to be able to investigate functional relationships between drugs and proteins and compare with localized phenomena? This review describes the various spatial levels of investigation offered by mass spectrometry imaging (MSI), and the advantages and disadvantages compared with other labeling technologies.  相似文献   

2.
Mass spectrometry imaging (MSI) determines the spatial localization and distribution patterns of compounds on the surface of a tissue section, mainly using MALDI (matrix assisted laser desorption/ionization)-based analytical techniques. New matrices for small-molecule MSI, which can improve the analysis of low-molecular weight (MW) compounds, are needed. These matrices should provide increased analyte signals while decreasing MALDI background signals. In addition, the use of ultrahigh-resolution instruments, such as Fourier transform ion cyclotron resonance (FTICR) mass spectrometers, has the ability to resolve analyte signals from matrix signals, and this can partially overcome many problems associated with the background originating from the MALDI matrix. The reduction in the intensities of the metastable matrix clusters by FTICR MS can also help to overcome some of the interferences associated with matrix peaks on other instruments. High-resolution instruments such as the FTICR mass spectrometers are advantageous as they can produce distribution patterns of many compounds simultaneously while still providing confidence in chemical identifications. Dithranol (DT; 1,8-dihydroxy-9,10-dihydroanthracen-9-one) has previously been reported as a MALDI matrix for tissue imaging. In this work, a protocol for the use of DT for MALDI imaging of endogenous lipids from the surfaces of mammalian tissue sections, by positive-ion MALDI-MS, on an ultrahigh-resolution hybrid quadrupole FTICR instrument has been provided.  相似文献   

3.
This review describes the current state of mass spectrometry imaging (MSI) in life sciences. A brief overview of mass spectrometry principles is presented followed by a thorough introduction to the MSI workflows, principles and areas of application. Three major desorption-ionization techniques used in MSI, namely, secondary ion mass spectrometry (SIMS), matrix-assisted laser desorption ionization (MALDI), and desorption electrospray ionization (DESI) are described, and biomedical and life science imaging applications of each ionization technique are reviewed. A separate section is devoted to data handling and current challenges and future perspectives are briefly discussed at the end.  相似文献   

4.
Biological imaging techniques are the most efficient way to locally measure the variation of different parameters on tissue sections. These analyses are gaining increasing interest since 20 years and allow observing extremely complex biological phenomena at lower and lower time and resolution scale. Nevertheless, most of them only target very few compounds of interest, which are chosen a priori, due to their low resolution power and sensitivity. New chemical imaging technique has to be introduced in order to overcome these limitations, leading to more informative and sensitive analyses for biologists and physicians.Two major mass spectrometry methods can be efficiently used to generate the distribution of biological compounds over a tissue section. Matrix-Assisted Laser Desorption/Ionisation-Mass Spectrometry (MALDI-MS) needs the co-crystallization of the sample with a matrix before to be irradiated by a laser, whereas the analyte is directly desorbed by a primary ion bombardment for Secondary Ion Mass Spectrometry (SIMS) experiments. In both cases, energy used for desorption/ionization is locally deposited -some tens of microns for the laser and some hundreds of nanometers for the ion beam- meaning that small areas over the surface sample can be separately analyzed. Step by step analysis allows spectrum acquisitions over the tissue sections and the data are treated by modern informatics software in order to create ion density maps, i.e., the intensity plot of one specific ion versus the (x,y) position.Main advantages of SIMS and MALDI compared to other chemical imaging techniques lie in the simultaneous acquisition of a large number of biological compounds in mixture with an excellent sensitivity obtained by Time-of-Flight (ToF) mass analyzer. Moreover, data treatment is done a posteriori, due to the fact that no compound is selectively marked, and let us access to the localization of different lipid classes in only one complete acquisition.  相似文献   

5.
Matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) has become a valuable tool to address a broad range of questions in many areas of biomedical research. One such application allows spectra to be obtained directly from intact tissues, termed "profiling" (low resolution) and "imaging" (high resolution). In light of the fact that MALDI tissue profiling allows over a thousand peptides and proteins to be rapidly detected from a variety of tissues, its application to disease processes is of special interest. For example, protein profiles from tumors may allow accurate prediction of tumor behavior, diagnosis, and prognosis and uncover etiologies underlying idiopathic diseases. MALDI MS, in conjunction with laser capture microdissection, is able to produce protein expression profiles from a relatively small number of cells from specific regions of heterogeneous tissue architectures. Imaging mass spectrometry enables the investigator to assess the spatial distribution of proteins, drugs, and their metabolites in intact tissues. This article provides an overview of several tissue profiling and imaging applications performed by MALDI MS, including sample preparation, matrix selection and application, histological staining prior to MALDI analysis, tissue profiling, imaging, and data analysis. Several applications represent direct translation of this technology to clinically relevant problems.  相似文献   

6.
In order to quantify small molecules at the early stage of drug discovery, we developed a quantitation approach based on mass spectrometry imaging (MSI) using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) without the use of a labeled compound. We describe a method intended to respond to the main challenges encountered in quantification through MALDI imaging dedicated to whole-body or single heterogeneous organ samples (brain, eye, liver). These include the high dependence of the detected signal on the matrix deposition, the MALDI ionization yield of specific target molecules, and lastly, the ion suppression effect on the tissue. To address these challenges, we based our approach on the use of a normalization factor called the TEC (Tissue Extinction Coefficient). This factor takes into account the ion suppression effect that is both tissue- and drug-specific. Through this protocol, the amount of drug per gram of tissue was determined, which in turn, was compared with other analytical techniques such as Liquid Chromatography-Mass spectrometry (LC-MS/MS).  相似文献   

7.
The identification of proteins involved in tumour progression or which permit enhanced or novel therapeutic targeting is essential for cancer research. Direct MALDI analysis of tissue sections is rapidly demonstrating its potential for protein imaging and profiling in the investigation of a range of disease states including cancer. MALDI‐mass spectrometry imaging (MALDI‐MSI) has been used here for direct visualisation and in situ characterisation of proteins in breast tumour tissue section samples. Frozen MCF7 breast tumour xenograft and human formalin‐fixed paraffin‐embedded breast cancer tissue sections were used. An improved protocol for on‐tissue trypsin digestion is described incorporating the use of a detergent, which increases the yield of tryptic peptides for both fresh frozen and formalin‐fixed paraffin‐embedded tumour tissue sections. A novel approach combining MALDI‐MSI and ion mobility separation MALDI‐tandem mass spectrometry imaging for improving the detection of low‐abundance proteins that are difficult to detect by direct MALDI‐MSI analysis is described. In situ protein identification was carried out directly from the tissue section by MALDI‐MSI. Numerous protein signals were detected and some proteins including histone H3, H4 and Grp75 that were abundant in the tumour region were identified.  相似文献   

8.
A novel linear ion trap (LIT) mass spectrometer with dual matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) ionization sources has been built in the MALDI-LIT-ESI configuration. The design features two independent ion source/ion optical channels connected to opposite ends of a single mass analyzer. The instrument consists of a commercial MALDI-LIT instrument modified by the addition of a home-built vacuum manifold, ion optical system, control electronics, and programming necessary to couple an atmospheric pressure interface to the commercial instrument. In addition to the added ESI functionality, the capabilities of the system also include simultaneous dual-channel ion introduction and analysis and high-duty cycle electronic switching (<1 s) between ion channels. Analytical and ion chemical applications of the dual-source system are explored. One analytical application is the enhanced protein sequence coverage achieved when using both ESI and MALDI to examine a tryptic digest of a six-protein mixture. The differences in the efficiency with which peptides in a mixture are ionized by the two methods give improved sequence coverage when both are applied. Other analytical applications include the use of the ions from one source as intensity or mass standards for the analyte ions from the other. An ion chemistry application involves the use of energy-resolved tandem mass spectrometry (MS/MS) to seek evidence for the generation of isomeric ions from a particular compound using the two ionization methods. A high level of agreement was achieved between the MS/MS spectra recorded under a variety of conditions after ESI and MALDI ionization; this provides evidence of the reproducibility and internal consistency of data from the dual source instrument. However, each of the peptides examined generated identical populations of structures in the two ionization methods under our conditions which are interpreted as involving slow cooling into the most stable minimum on the potential energy surface.  相似文献   

9.
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry (MS) is a highly versatile and sensitive analytical technique, which is known for its soft ionisation of biomolecules such as peptides and proteins. Generally, MALDI MS analysis requires little sample preparation, and in some cases like MS profiling it can be automated through the use of robotic liquid-handling systems. For more than a decade now, MALDI MS has been extensively utilised in the search for biomarkers that could aid clinicians in diagnosis, prognosis, and treatment decision making. This review examines the various MALDI-based MS techniques like MS imaging, MS profiling and proteomics in-depth analysis where MALDI MS follows fractionation and separation methods such as gel electrophoresis, and how these have contributed to prostate cancer biomarker research. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge.  相似文献   

10.
Fundamental advances in secondary ion mass spectrometry (SIMS) now allow for the examination and characterization of lipids directly from biological materials. The successful application of SIMS-based imaging in the investigation of lipids directly from tissue and cells are demonstrated. Common complications and technical pitfalls are discussed. In this review, we examine the use of cluster ion sources and cryogenically compatible sample handling for improved ion yields and to expand the application potential of SIMS. Methodological improvements, including pre-treating the sample to improve ion yields and protocol development for 3-dimensional analyses (i.e. molecular depth profiling), are also included in this discussion. New high performance SIMS instruments showcasing the most advanced instrumental developments, including tandem MS capabilities and continuous ion beam compatibility, are described and the future direction for SIMS in lipid imaging is evaluated.  相似文献   

11.
Single-cell analysis is gaining popularity in the field of mass spectrometry as a method for analyzing protein and peptide content in cells. The spatial resolution of MALDI mass spectrometry (MS) imaging is by a large extent limited by the laser focal diameter and the displacement of analytes during matrix deposition. Owing to recent advancements in both laser optics and matrix deposition methods, spatial resolution on the order of a single eukaryotic cell is now achievable by MALDI MS imaging. Provided adequate instrument sensitivity, a lateral resolution of ?10 µm is currently attainable with commercial instruments. As a result of these advances, MALDI MS imaging is poised to become a transformative clinical technology. In this article, the crucial steps needed to obtain single-cell resolution are discussed, as well as potential applications to disease research.  相似文献   

12.
Previous studies in our group have shown that the analyte signal in a matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) experiment is strongly influenced by the binding interactions between the target surface and the analyte. Specifically, the analyte signal increases with decreases in surface binding affinity, which has been attributed to more unbound analyte being available for incorporation within the MALDI matrix. In this work, polyethylene glycol (PEG) was chemically grafted onto a polyurethane (PU) film to produce a MALDI target having reduced surface-protein binding affinity, and the effect of this modification on protein MALDI ion signals was investigated. The proteins myoglobin, lysozyme, and albumin were used to evaluate the PEG PU modified target as compared with a PU target and a commercial stainless steel target. It is shown that there are enhancements in the protein MALDI ion signals on the PEG PU modified target and that the limit of detection for these proteins is decreased by a factor of 2 to 6 in comparison with the unmodified PU and the commercial stainless steel targets.  相似文献   

13.
MALDI profiling and imaging mass spectrometry (IMS) are novel techniques for direct analysis of peptides and small proteins in biological tissues. In this work we applied them to the study of Anopheles gambiae antennae, with the aim of analysing expression of soluble proteins involved in olfaction perireceptor events. MALDI spectra obtained by direct profiling on single antennae and by the analysis of extracts, showed similar profiles, although spectra obtained through profiling had a richer ion population and higher signal to noise ratio. Male and female antennae showed distinct protein profiles. MALDI imaging experiments were also performed and differences were observed in the localization of some proteins. Two proteins were identified through high resolution measurement and top-down MS/MS experiments. A 8 kDa protein only present in the male antennae matched with an unannotated sequence of the An. gambiae genome, while the presence of odorant binding protein 9 (OBP-9) was confirmed through experiments of 2-DE, followed by MS and MS/MS analysis of digested spots. This work shows that MALDI MS profiling is a technique suitable for the analysis of proteins of small and medium MW in insect appendices, and allows obtaining data for several specimens which can be investigated for differences between groups. Proteins of interest can be identified through other complementary MS approaches.  相似文献   

14.
Serum protein profiling by mass spectrometry is a promising method for early detection of cancer. We have implemented a combined strategy based on matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) and statistical data analysis for serum protein profiling and applied it in a well-described breast cancer case-control study. A rigorous sample collection protocol ensured high quality specimen and reduced bias from preanalytical factors. Preoperative serum samples obtained from 48 breast cancer patients and 28 controls were used to generate MALDI MS protein profiles. A total of nine mass spectrometric protein profiles were obtained for each serum sample. A total of 533 common peaks were defined and represented a 'reference protein profile'. Among these 533 common peaks, we identified 72 peaks exhibiting statistically significant intensity differences ( p < 0.01) between cases and controls. A diagnostic rule based on these 72 mass values was constructed and exhibited a cross-validated sensitivity and specificity of approximately 85% for the detection of breast cancer. With this method, it was possible to distinguish early stage cancers from controls without major loss of sensitivity and specificity. We conclude that optimized serum sample handling and mass spectrometry data acquisition strategies in combination with statistical analysis provide a viable platform for serum protein profiling in cancer diagnosis.  相似文献   

15.
The virtues and limitations of SIMS ion microscopy are compared with other spectroscopic techniques applicable to biological microanalysis, with a special emphasis on techniques for elemental localization in biological tissue (electron, X-ray, laser, nuclear, ion microprobes). Principal advantages of SIMS include high detection sensitivity, high depth resolution, isotope specificity, and possibilities for three-dimensional imaging. Current limitations, especially in comparison to X-ray microanalysis, center on lateral spatial resolution and quantification. Recent SIMS instrumentation advances involving field emission liquid metal ion sources and laser post-ionization will help to minimize these limitations in the future. The molecular surface analysis capabilities of static SIMS, especially with the new developments in commercial time-of-flight spectrometers, are promising for application to biomimetic, biomaterials, and biological tissue or cell surfaces. However, the direct microchemical imaging of biomolecules in tissue samples using SIMS will be hindered by limited concentrations, small analytical volumes, and the inefficiencies of converting surface molecules to structurally significant gas phase ions. Indirect detection using elemental or isotopically tagged molecules, however, shows considerable promise for molecular imaging studies using SIMS ion microscopy.  相似文献   

16.
The intraocular lens contains high levels of both cholesterol and sphingolipids, which are believed to be functionally important for normal lens physiology. The aim of this study was to explore the spatial distribution of sphingolipids in the ocular lens using mass spectrometry imaging (MSI). Matrix-assisted laser desorption/ionization (MALDI) imaging with ultra high resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was used to visualize the lipid spatial distribution. Equatorially-cryosectioned, 12 μm thick slices of tissue were thaw-mounted to an indium-tin oxide (ITO) glass slide by soft-landing to an ethanol layer. This procedure maintained the tissue integrity. After the automated MALDI matrix deposition, the entire lens section was examined by MALDI MSI in a 150 μm raster. We obtained spatial- and concentration-dependent distributions of seven lens sphingomyelins (SM) and two ceramide-1-phosphates (CerP), which are important lipid second messengers. Glycosylated sphingolipids or sphingolipid breakdown products were not observed. Owing to ultra high resolution MS, all lipids were identified with high confidence, and distinct distribution patterns for each of them are presented. The distribution patterns of SMs provide an understanding of the physiological functioning of these lipids in clear lenses and offer a novel pathophysiological means for understanding diseases of the lens.  相似文献   

17.
The rhizome of Glycyrrhiza glabra (licorice) was analyzed by high‐resolution mass spectrometry imaging and tandem mass spectrometry imaging. An atmospheric pressure matrix‐assisted laser desorption/ionization imaging ion source was combined with an orbital trapping mass spectrometer in order to obtain high‐resolution imaging in mass and space. Sections of the rhizome were imaged with a spatial resolution of 10 μm in the positive ion mode, and a large number of secondary metabolites were localized and identified based on their accurate mass and MS/MS fragmentation patterns. Major tissue‐specific metabolites, including free flavonoids, flavonoid glycosides and saponins, were successfully detected and visualized in images, showing their distributions at the cellular level. The analytical power of the technique was tested in the imaging of two isobaric licorice saponins with a mass difference of only 0.02 Da. With a mass resolving power of 140 000 and a bin width of 5 ppm in the image processing, the two compounds were well resolved in full‐scan mode, and appeared with different distributions in the tissue sections. The identities of the compounds and their distributions were validated in a subsequent MS/MS imaging experiment, thereby confirming their identities and excluding possible analyte interference. The use of high spatial resolution, high mass resolution and tandem mass spectrometry in imaging experiments provides significant information about the biosynthetic pathway of flavonoids and saponins in legume species, combing the spatially resolved chemical information with morphological details at the microscopic level. Furthermore, the technique offers a scheme capable of high‐throughput profiling of metabolites in plant tissues.  相似文献   

18.
Lobinski R  Moulin C  Ortega R 《Biochimie》2006,88(11):1591-1604
Mineral elements, often at the trace level, play a considerable role in physiology and pathology of biological systems. Metallogenomics, metalloproteomics, and metallomics are among the emerging disciplines which are critically dependent on spatially resolved concentration maps of trace elements in a cell or tissue, on information on chemical speciation, and on that on metal-binding coordination sites. The mini-review discusses recent progress in analytical techniques for element profiling on the genome scale, biological trace element imaging, and probing, identification and quantification of chemical species in the biological environment. Imaging of the element distribution in cells and tissue sections is becoming possible with sub-micrometer spatial resolution and picogram-level sensitivity owing to advances in laser ablation MS, ion beam and synchrotron radiation X-ray fluorescence microprobes. Progress in nanoflow chromatography and capillary electrophoresis coupled with element specific ICP MS and molecule-specific electrospray MS/MS and MALDI enables speciation of elements in microsamples in a complex biological environment. Laser ablation ICP MS, micro-SXRF, and micro-PIXE allow mapping of trace element distribution in 1D and 2D proteomics gels. The increasing sensitivity of EXAFS and XANES owing to the use of more intense synchrotron beams and efficient focusing optics provide information about oxidation state, fingerprint speciation of metal sites and metal-site structures.  相似文献   

19.
Direct tissue profiling and imaging mass spectrometry (MS) provides a detailed assessment of the complex protein pattern within a tissue sample. MALDI MS analysis of thin tissue sections results in over of 500 individual protein signals in the mass range of 2 to 70 kDa that directly correlate with protein composition within a specific region of the tissue sample. To date, profiling and imaging MS has been applied to multiple diseased tissues, including human gliomas and nonsmall cell lung cancer. Interrogation of the resulting complex MS data sets has resulted in identification of both disease-state and patient-prognosis specific protein patterns. These results suggest the future usefulness of proteomic information in assessing disease progression, prognosis, and drug efficacy.  相似文献   

20.
Measuring the peptides in individual organelles with mass spectrometry   总被引:4,自引:0,他引:4  
New sampling protocols combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) allow the assay of single dense core vesicles. Understanding the packaging of vesicles is important as vesicles are the quanta of information for intercellular communication. Using vesicles from the exocrine atrial gland of Aplysia californica as the model, a wide range of bioactive peptides are detected within each vesicle. Although the expression of the egg-laying hormone gene family of type 1 atrial gland cells has been previously examined, chemical characterization of individual 1-2 microm diameter vesicles demonstrates that products from several genes are colocalized. The mass sensitivity of MALDI MS can be further improved to enable the analysis of even smaller subcellular organelles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号