首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Repetitive low-force contractions are common in the workplace and yet can lead to muscle fatigue and work-related musculoskeletal disorders. The current study aimed to investigate potential motion adaptations during a simulated repetitive light assembly work task designed to fatigue the shoulder region, focusing on changes over time and age-related group differences. Ten younger and ten older participants performed four 20-min task sessions separated by short breaks. Mean and variability of joint angles and scapular elevation, joint net moments for the shoulder, elbow, and wrist were calculated from upper extremity kinematics recorded by a motion tracking system. Results showed that joint angle and joint torque decreased across sessions and across multiple joints and segments. Increased kinematic variability over time was observed in the shoulder joint; however, decreased kinematic variability over time was seen in the more distal part of the upper limb. The changes of motion adaptations were sensitive to the task-break schedule. The results suggested that kinematic and kinetic adaptations occurred to reduce the biomechanical loading on the fatigued shoulder region. In addition, the kinematic and kinetic responses at the elbow and wrist joints also changed, possibly to compensate for the increased variability caused by the shoulder joint while still maintaining task requirements. These motion strategies in responses to muscle fatigue were similar between two age groups although the older group showed more effort in adaptation than the younger in terms of magnitude and affected body parts.  相似文献   

2.
The menisci play an important role in load distribution, load bearing, joint stability, lubrication, and proprioception. Partial meniscectomy has been shown to result in changes in the kinematics and kinetics at the knee during gait that can lead to progressive meniscal degeneration. This study examined changes in the strains within the menisci associated with kinematic and kinetic changes during the gait cycle. The gait changes considered were a 5 deg shift toward external rotation of the tibia with respect to the femur and an increased medial-lateral load ratio representing an increased adduction moment. A finite element model of the knee was developed and tested using a cadaveric specimen. The cadaver was placed in positions representing heel-strike and midstance of the normal gait, and magnetic resonance images were taken. Comparisons of the model predictions to boundaries digitized from images acquired in the loaded states were within the errors produced by a 1 pixel shift of either meniscus. The finite element model predicted that an increased adduction moment caused increased strains of both the anterior and posterior horns of the medial meniscus. The lateral meniscus exhibited much lower strains and had minimal changes under the various loading conditions. The external tibial rotational change resulted in a 20% decrease in the strains in the posterior medial horn and increased strains in the anterior medial horn. The results of this study suggest that the shift toward external tibial rotation seen clinically after partial medial meniscectomy is not likely to cause subsequent degenerative medial meniscal damage, but the consequence of this kinematic shift on the pathogenesis of osteoarthritis following meniscectomy requires further consideration.  相似文献   

3.
The dynamic properties of instrumented treadmills influence the force measurement of the embedded force platform. We investigated these properties using a frequency response function, which evaluates the ratio between the measured and applied forces in the frequency domain. For comparison, the procedure was also performed on the gold-standard ground-embedded force platform. A predictive model of the systematic error of both types of force platform was then developed and tested against different input signals that represent three types of running patterns. Results show that the treadmill structure distorts the measured force signal. We then modified this structure with a simple stiffening frame in an attempt to reduce measurement error. Consequently, the overall absolute error was reduced (−22%), and the error in force-derived metrics was also sufficiently reduced: −68% for average loading rate error and −80% for impact peak error. Our procedure shows how to measure, predict, and reduce systematic dynamic error associated with treadmill-installed force platforms. We suggest this procedure should be implemented to appraise data quality, and frequency response function values should be included in research reports.  相似文献   

4.
This paper investigated application of a machine learning approach (Support vector machine, SVM) for the automatic recognition of gait changes due to ageing using three types of gait measures: basic temporal/spatial, kinetic and kinematic. The gaits of 12 young and 12 elderly participants were recorded and analysed using a synchronized PEAK motion analysis system and a force platform during normal walking. Altogether, 24 gait features describing the three types of gait characteristics were extracted for developing gait recognition models and later testing of generalization performance. Test results indicated an overall accuracy of 91.7% by the SVM in its capacity to distinguish the two gait patterns. The classification ability of the SVM was found to be unaffected across six kernel functions (linear, polynomial, radial basis, exponential radial basis, multi-layer perceptron and spline). Gait recognition rate improved when features were selected from different gait data type. A feature selection algorithm demonstrated that as little as three gait features, one selected from each data type, could effectively distinguish the age groups with 100% accuracy. These results demonstrate considerable potential in applying SVMs in gait classification for many applications.  相似文献   

5.
Kinematic variables of the vertical jump (jumping height, jump phase durations and joint angles) were measured on 39 male physical education students. In addition, kinetic parameters of the hip and knee extensors, and of the plantar flexors (maxima voluntary force and its rate of development) were recorded on the same subjects, in isometric conditions. The results demonstrated significant positive correlations between kinetic parameters of the active muscle groups and jumping height (r = 0.217-0.464). The dominant effect on these correlations was due to the knee extensors. Correlations between these parameters and the duration of the jump phases were much weaker. Correlation coefficients between kinetic parameters and limb angles in the lowest body position showed that fast force production in one muscle group was related to a significant decrease in the joint angles of distant body segments. Multiple correlation coefficients between leg extensor parameters and kinematic variables (ranging between 0.256 for the duration of the counter-movement phase and 0.616 for jump height) suggested that kinetic parameters could explain more than a quarter of the variability of this complex human movement. Therefore, the conclusion was drawn that an extended set of measurements of the relevant musculo-skeletal system parameters could predict a considerable amount of the variability of human movement. However, high correlation coefficients between the same kinetic parameters of different muscle groups suggest that not all active muscle groups have to be included in the measurements.  相似文献   

6.
Hemiplegic gait: a kinematic analysis using walking speed as a basis.   总被引:8,自引:0,他引:8  
The kinematics of treadmill ambulation of stroke patients (N = 9) and healthy subjects (N = 4) was studied at a wide range of different velocities (i.e. 0.25-1.5 m s-1), with a focus on the transverse rotations of the trunk. Video recordings revealed, for both stroke patients and healthy subjects, similar relations between walking speed and stride length as well as stride frequency. The phase difference between pelvic and thoracic rotations (i.e. trunk rotation) and the total range of trunk rotation were almost linearly related to the walking speed. Healthy subjects showed a marked increase in pelvic rotation from 1 to 1.5 m s-1. Using dimensional analysis in a comparison between stroke patients and healthy subjects, invariances in the coordination of gait were found for stride length, stride frequency, pelvic rotation, and trunk rotation. Constant relations were obtained between, on the one hand, dimensionless velocity and, on the other, dimensionless stride length as well as stride frequency. Transitions were found between the velocities 0.75 and 1 m s-1 for dimensionless pelvic rotation and trunk rotation, indicating that, from this velocity range onwards, pelvic swing lengthens the stride: rotations of pelvis, thorax and trunk become tightly coordinated. On the basis of the dimensionless stride length, stride frequency, pelvic rotation and trunk rotation, deficits in the gait of stroke patients could be quantified. It is concluded that walking speed is an important control parameter, which should be used as a basic variable in the evaluation of the gait of stroke patients.  相似文献   

7.
Footwear devices that shift foot center of pressure (COP), thereby impacting lower-limb biomechanics to produce clinical benefit, have been studied regarding degenerative diseases of knee and hip joints, exhibiting evidence of clinical success. Ability to purposefully affect trunk biomechanics has not been investigated for this type of footwear. Fifteen healthy young male subjects underwent gait and electromyography analysis using a biomechanical device that shifts COP via moveable convex elements attached to the shoe sole. Analyses were performed in three COP configurations for pairwise comparison: (1) neutral (control) (2) laterally deviated, and (3) medially deviated. Sagittal and frontal-plane pelvis and spine kinematics, external oblique activity, and frontal and transverse-plane lumbar moments were affected by medio-lateral COP shift. Transverse-plane trunk kinematics, activity of the lumbar longissimus, latissimus dorsi, rectus abdominus, and quadratus lumborum, and sagittal-plane lumbar moment, were not significantly impacted. Two linear mixed effects models assessed predictive impact of (I) COP location, and (II) trunk kinematics and neuromuscular activity, on the significant lumbar moment parameters. The COP was a significant predictor of all modeled frontal and transverse-plane lumbar moment parameters, while pelvic and spine rotation, and lumbar longissimus activity were significant predictors of one frontal-plane lumbar moment parameter. Model results suggest that, although trunk biomechanics and muscle activity were altered by COP shift, COP offset influences lumbar kinetics directly, or via lower-limb changes not assessed in this study, but not by means of alteration of trunk kinematics or muscle activity. Further study may reveal implications in treatment of low back pain.  相似文献   

8.

Introduction

Osteoarthritis (OA) results in pain and disability; however, preclinical OA models often focus on joint-level changes. Gait analysis is one method used to evaluate both preclinical OA models and OA patients. The objective of this study is to describe spatiotemporal and ground reaction force changes in a rat medial meniscus transection (MMT) model of knee OA and to compare these gait measures with assays of weight bearing and tactile allodynia.

Methods

Sixteen rats were used in the study. The medial collateral ligament (MCL) was transected in twelve Lewis rats (male, 200 to 250 g); in six rats, the medial meniscus was transected, and the remaining six rats served as sham controls. The remaining four rats served as naïve controls. Gait, weight-bearing as measured by an incapacitance meter, and tactile allodynia were assessed on postoperative days 9 to 24. On day 28, knee joints were collected for histology. Cytokine concentrations in the serum were assessed with a 10-plex cytokine panel.

Results

Weight bearing was not affected by sham or MMT surgery; however, the MMT group had decreased mechanical paw-withdrawal thresholds in the operated limb relative to the contralateral limb (P = 0.017). The gait of the MMT group became increasingly asymmetric from postoperative days 9 to 24 (P = 0.020); moreover, MMT animals tended to spend more time on their contralateral limb than their operated limb while walking (P < 0.1). Ground reaction forces confirmed temporal shifts in symmetry and stance time, as the MMT group had lower vertical and propulsive ground reaction forces in their operated limb relative to the contralateral limb, naïve, and sham controls (P < 0.05). Levels of interleukin 6 in the MMT group tended to be higher than naïve controls (P = 0.072). Histology confirmed increased cartilage damage in the MMT group, consistent with OA initiation. Post hoc analysis revealed that gait symmetry, stance time imbalance, peak propulsive force, and serum interleukin 6 concentrations had significant correlations to the severity of cartilage lesion formation.

Conclusion

These data indicate significant gait compensations were present in the MMT group relative to medial collateral ligament (MCL) injury (sham) alone and naïve controls. Moreover, these data suggest that gait compensations are likely driven by meniscal instability and/or cartilage damage, and not by MCL injury alone.  相似文献   

9.
Respirometry was used for the characterization of active autotrophic and heterotrophic biomass in a pilot scale moving bed bioreactor (MBBR). For this purpose biofilm samples attached to the carrier elements of the MBBR were transferred to a static gas/static liquid type respirometer with intermittent aeration. Known amounts of ammonia nitrogen and acetate were added to the respirometer. The dissolved oxygen (DO) decrease during the non-aeration phase was measured and used to calculate the oxygen uptake rate (OUR) of the active biomass. The resulting respirograms featured the typical endogenous and exogenous respiration phases and the shape of the respirogram was as expected from analogous respirometry with activated sludge. The OUR response was modelled with the activated sludge model ASM1 and the relevant kinetic parameter values for autotrophic and heterotrophic growth were adjusted. The adjusted parameter set and data originating from a 4-day long intensive measurement campaign were used for modelling and simulation of the pilot scale MBBR. The parameter estimation resulted in a good dynamic simulation of ammonia and nitrate variations in the effluent of the MBBR. Important MBBR properties including biofilm age, biofilm composition, and both attachment and detachment rate were extracted from the model.  相似文献   

10.
Phase reset and dynamic stability during human gait   总被引:1,自引:0,他引:1  
Yamasaki T  Nomura T  Sato S 《Bio Systems》2003,71(1-2):221-232
The human walking movement shows transient changes in response to single short-lived external perturbations, termed "stumbling reactions." During the stumbling reactions, the walking phase is reset. It has been considered that the reactions contribute to stabilizing the motion, but less evidence bridging between the rhythm reset and the dynamic stability of the gait has been provided. The present study tries to establish the relationship between them. To this end, we construct a simple dynamical system model of the human musculo-skeletal system interacting with the ground, whose joint kinematics during walking is constrained by a given periodic joint-angles-profile. We show first that the model can exhibit a stable limit cycle corresponding to the steady walking with no perturbations. The responses of the limit cycle oscillation are examined by applying a type of perturbations at various timings with various intensities, elucidating the stability of the model's walking when no phase reset is performed. We then observe that modifications of the periodic joint-angles-profile within a short time interval in response to the perturbation can alter the responses of the limit cycle oscillation and induce phase reset of the model's walking. It is shown that appropriate amounts of the phase reset can prevent the model from falling, even for the perturbation that induces falling in the case without the phase reset. This suggests that those phase resets can improve the dynamic stability of the gait. Moreover, the appropriate phase resets predicted by the model are compared with the experimentally observed phase resets during human stumbling reaction to show they share similar characteristics.  相似文献   

11.
Current clinical interpretation of dynamic electromyography (EMG) data is usually based on qualitative assessments of muscle timing. Cross-correlation may provide a method for objectively comparing the timing and shape of EMG signals. This study used cross-correlation to compare EMG signals from different walking trials, different test sessions, and different individuals in able-bodied adults. Cross-correlation results (R-values) for different walking trials within a single test session were high, averaging > or = 0.90 for all muscles tested (R = 1.0 indicates exact agreement). Cross-correlation values were also high among trials from different test sessions conducted by the same and different examiners (average R > or = 0.78 for all muscles). R-values were much more variable when comparing different subjects (average 0.40-0.81, range 0.00-0.91). R-values were lower for the medial hamstrings and rectus femoris compared with the other muscles tested. These results suggest that cross-correlation may be useful for evaluating changes in an individual patient's muscle activation patterns, such as before and after surgery, but not for comparing EMG patterns among different individuals, such as between patients and normative data. This is especially true for biarticular muscles such as the hamstrings and rectus femoris, which may have variable activation patterns and/or increased sensitivity to electrode placement. Cross-correlation may also be useful for identifying appropriate muscles for transfer, identifying "outlier" trials within a test session, and selecting representative EMG curves for a given patient. The advantages of cross-correlation are that it considers shape of the EMG signal in addition to timing and that the assessments it provides are objective, rather than subjective.  相似文献   

12.
It is believed that nurses risk the development of back pain as a consequence of sudden loadings during tasks in which they are handling patients. Forward dynamics simulations of sudden loads (applied to the arms) during dynamic lifting tasks were performed on a two-dimensional whole-body model. Loads were in the range of -80 kg to 80 kg, with the initial load being 20 kg. Loading the arm downwards with less than that which equals a mass of 20 kg did not change the compressive forces on the spine when compared to a normal lifting motion with a 20 kg mass in the hands. However when larger loads (40 kg to 80 kg extra in the hands) were simulated, the compressive forces exceeded 13,000 N (above 3400 N is generally considered a risk factor). Loading upwards led to a decrease in the compressive forces but to a larger backwards velocity at the end of the movement. In the present study, it was possible to simulate a fast lifting motion. The results showed that when loading the arms downwards with a force that equals 40 kg or more, the spine was severely compressed. When loading in the opposite direction (unloading), the spine was not compressed more than during a normal lifting motion. In practical terms, this indicates that if a nursing aide tries to catch a patient who is falling, large compressive forces are applied to the spine.  相似文献   

13.
The purpose of the study was to characterize the Balance-Dexterity Task as a means to investigate a concurrent bipedal lower-extremity task and trunk control during dynamic balance. The task combines aspects of single-limb balance and the lower-extremity dexterity test by asking participants to stand on one limb while compressing an unstable spring with the contralateral limb to an individualized target force. Nineteen non-disabled participants completed the study, and performance measures for the demands of each limb – balance and dexterous force control – as well as kinematic and electromyographic measures of trunk control were collected. Given five practice trials, participants achieved compression forces ranging from 100 to 139 N (mean 121.2 ± 12.3 N), representing 14.4–23.0% of body weight (mean 18.7 ± 2.4%), which were then presented as target forces during test trials. Dexterous force control coefficient of variation and average magnitude of the center of pressure (COP) resultant velocity were associated such that greater variability in force control was accompanied by greater COP velocity (R = 0.598, p = 0.007). Trunk coupling, quantified as the coefficient of determination (R2) of a frontal plane thorax and pelvis angle-angle plot, varied independently of any measure of balance or dexterous force control. The Balance-Dexterity Task is a continuous, dynamic balance task where bipedal coordination and trunk coupling can be concurrently observed and studied.  相似文献   

14.
This paper describes a system for measuring the temporal and spatial parameters of gait. The basis of the system in a resistive grid walkway which is controlled by a microcomputer which also collects, processes and stores the data from the walkway. The data obtained from the system, including the temporal and spatial parameters of gait such as step and stride lengths, the durations of swing and support phases of the gait cycle and walking speed, are presented in both numerical and graphical forms. Accuracy to within 1 cm has been verified by analysing videotapes of foot placement during a walk. Special emphasis has been placed on making the system software user-friendly. The presentation of date uses several types of display, from a simple graphical summary of the walk statistics to a more complete report showing all the data from each stride. In the year during which the walkway system has been operational, it has been found easy to use by both subjects and operators, and it produces very useful data.  相似文献   

15.
16.
17.
The ability to develop high levels of muscular power is considered a fundamental component for many different sporting activities; however, the load that elicits peak power still remains controversial. The primary aim of this study was to determine at which load peak power output occurs during the midthigh clean pull. Sixteen participants (age 21.5 ± 2.4 years; height 173.86 ± 7.98 cm; body mass 70.85 ± 11.67 kg) performed midthigh clean pulls at intensities of 40, 60, 80, 100, 120, and 140% of 1 repetition maximum (1RM) power clean in a randomized and balanced order using a force plate and linear position transducer to assess velocity, displacement, peak power, peak force (Fz), impulse, and rate of force development (RFD). Significantly greater Fz occurred at a load of 140% (2,778.65 ± 151.58 N, p < 0.001), impulse within 100, 200, and 300 milliseconds at a load of 140% 1RM (196.85 ± 76.56, 415.75 ± 157.56, and 647.86 ± 252.43 N·s, p < 0.023, respectively), RFD at a load of 120% (26,224.23 ± 2,461.61 N·s, p = 0.004), whereas peak velocity (1.693 ± 0.042 m·s, p < 0.001) and peak power (3,712.82 ± 254.38 W, p < 0.001) occurred at 40% 1RM. Greatest total impulse (1,129.86 ± 534.86 N·s) was achieved at 140% 1RM, which was significantly greater (p < 0.03) than at all loads except the 120% 1RM condition. Results indicate that increased loading results in significant (p < 0.001) decreases in peak power and peak velocity during the midthigh clean pull. Moreover, if maximizing force production is the goal, then training at a higher load may be advantageous, with peak Fz occurring at 140% 1RM.  相似文献   

18.
In this work, a procedure for estimating kinetic parameters in biochemically structured models was developed. The approach is applicable when the structure of a kinetic model has been set up and the kinetic parameters should be estimated. The procedure consists of five steps. First, initial values were found in or calculated from literature. Hereafter using sensitivity analysis the most sensitive parameters were identified. In the third step physiological knowledge was combined with the parameter sensitivities to manually tune the most sensitive parameters. In step four, a global optimisation routine was applied for simultaneous estimation of the most sensitive parameters identified during the sensitivity analysis. Regularisation was included in the simultaneous estimation to reduce the effect of insensitive parameters. Finally, confidence intervals for the estimated parameters were calculated. This parameter estimation approach was demonstrated on a biochemically structured yeast model containing 11 reactions and 37 kinetic constants as a case study.  相似文献   

19.
A three-dimensional dynamic model of the tibiofemoral and patellofemoral articulations was developed to predict the motions of knee implants during a step-up activity. Patterns of muscle activity, initial joint angles and velocities, and kinematics of the hip and tinkle were measured experimentally and used as inputs to the simulation. Prosthetic knee kinematics were determined by integration of dynamic equations of motion subject to forces generated by muscles, ligaments, and contact at both the tibiofemoral and patellofemoral articulations. The modeling of contacts between implants did not rely upon explicit constraint equations; thus, changes in the number of contact points were allowed without modification to the model formulation. The simulation reproduced experimentally measured flexion-extension angle of the knee (within one standard deviation), but translations at the tibiofemoral articulations were larger during the simulated step-up task than those reported for patients with total knee replacements.  相似文献   

20.
This paper examines changes in the variability of electromyographic (EMG) activity and kinematics as a result of practicing a maximal performance task. Eight subjects performed rapid elbow flexion to a target in the horizontal plane. Four hundred trials were distributed equally over four practice sessions. A potentiometer at the elbow axis of rotation of a manipulandum recorded the angular displacement. The EMG activity of the biceps and the triceps brachii was monitored using Beckman surface electrodes. Limb speed increased while both target error and trajectory (velocity versus position) variability decreased. There was an increase in the absolute measure of total EMG variability (the first standard deviation at each point of the biceps and triceps waveform multiplied together). However, the coefficient of variation (the first standard deviation divided by the mean and the result multiplied by 100) of the mean amplitude value of the individual EMG bursts decreased. The variability of triceps motor time also decreased while the variability biceps motor time remained unchanged. The results demonstrated a clear relationship between kinematic and EMG variability. The EMG and the trajectory data suggest that practice resulted in greater central nervous system control over both the spatial-temporal aspects of movement and the magnitude of the biceps and triceps muscle force-impulses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号