首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Haemophilus influenzae b conjugate vaccines (Hib) are almost entirely evaluated by physico-chemical methods to ensure the consistency of manufacture of batches. As different assays are employed for the quantification of Hib capsular polysaccharide PRP (polyribosyl ribitol phosphate; 5-D-ribitol-(1-->1)-beta-D-ribose-3-phosphate) in final formulations and bulk components, there was deemed a need for an International Standard of Hib PRP polysaccharide to be made available. Ten laboratories from 8 different countries participated in a collaborative study to determine the PRP content and assess the suitability of a candidate International Standard PRP preparation (02/208). The results illustrate that a reduction in between-laboratory variability could be achieved by use of a common reference preparation and data analysis showed no significant differences in the values obtained by the different assays: ribose, phosphorus, and high performance anion exchange chromatography-pulsed amperometric detection (HPAEC-PAD), suggesting the suitability of the proposed reference for use across these assays for quantification of PRP content in Hib vaccines. On the basis of the results of this study, the First International Standard for PRP, NIBSC Code 02/208, has been established by the Expert Committee of Biological Standards of the World Health Organisation, with a content of 4.933+/-0.267mg/ampoule, as determined by the ribose assays carried out by 7 of the participating laboratories.  相似文献   

2.
Japanese encephalitis (JE) viruses are grouped into four genotypes. Although currently available vaccines are derived only from viruses in genotype III, vaccines are known to protect against naturally occurring strains. Studies were undertaken to assess the suitability of a freeze-dried pool of human anti-JE plasma, collected from recipients of Biken (Nakayama-NIH) killed vaccine, to serve as an International Standard for antibodies to JE virus. Five participants in five countries submitted data from 11 assays on the candidate International Standard and seven coded samples including sera from recipients of vaccines containing a range of virus strains. The results of the study indicated that the 50% plaque reduction neutralization test (PRNT(50)titres) obtained for serum from recipients of killed vaccines, including the candidate standard, vary depending on the virus strain used in the neutralization tests, namely higher PRNT(50)titres were obtained when the challenge virus was homologous to the vaccine strain compared to use of a heterologous virus. Potencies expressed relative to the candidate standard are therefore affected by the strain of virus used in assays and the use of a standard would therefore not facilitate direct comparison of data from laboratories that have used different challenge strains.  相似文献   

3.
Whole cell pertussis vaccine is still widely used in many countries. An International Standard is needed for its potency control. The Third International Standard for Pertussis Vaccine was prepared about 40 years ago and its replacement was recommended by the Expert Committee for Biological Standardisation (ECBS) of the WHO. Material in ampoules coded 94/532 was prepared as a candidate replacement and has been evaluated in international collaborative studies which consisted of two parts. The first part, to assess the suitability of the candidate standard by comparing it with the Second International Standard for Pertussis Vaccine (IS2) involved 14 laboratories in 11 countries. The second part to compare the candidate standard with the Third International Standard for Pertussis Vaccine (IS3) involved 16 laboratories in 14 countries. Since 1995 various other studies have included the international standards and the results of these are also considered in assessing likely continuity of the IU for potency of whole cell pertussis vaccine. The preparation in ampoules coded 94/532 was adopted by the WHO ECBS in October 2006 as the 4th International Standard for whole cell pertussis vaccine and assigned an activity of 40 IU per ampoule on the basis of the studies reported here.  相似文献   

4.
John Saldanha 《Biologicals》1999,27(4):285-289
The introduction of nucleic acid amplification technology (NAT) assays for the detection of viral contamination of blood and blood products requires the availability of well-characterized reference reagents. Working reagents for hepatitis C virus RNA, hepatitis B virus DNA, HIV-1 RNA and human parvovirus B19 DNA have been established at NIBSC and at many other laboratories (both official medicinal control laboratories and commercial laboratories). However, as these reagents have been characterised independently, it is difficult to compare results from assays using different working reagents. Recently, a WHO International Standard was established for HCV RNA NAT assays. This standard has been calibrated in International Units (IU) and provides a common standard against which all working reagents can be calibrated. Collaborative studies to characterise two further candidate International Standards for HBV DNA and HIV-1 RNA NAT assays have been completed.  相似文献   

5.
Yellow fever vaccines are routinely assayed by plaque assay. However, the results of these assays are then converted into mouse LD(50) using correlations/conversion factors which, in many cases, were established many years ago. The minimum required potency in WHO Recommendations is 10(3) LD(50)/dose. Thirteen participants from 8 countries participated in a collaborative study whose aim was to assess the suitability of two candidate preparations to serve as an International Standard for yellow fever vaccine. In addition, the study investigated the relationship between the mouse LD(50) test and plaque forming units with a view to updating the WHO recommendations. Plaque assays were more reproducible than mouse assays, as expected. Differences in sensitivities of plaque assays were observed between laboratories but these differences appear to be consistent within a laboratory for all samples and the expression of potency relative to the candidate standard vaccine improved the reproducibility of assays between laboratories. However, the use of potencies had little effect on the between laboratory variability in mouse LD(50) assays. There appears to be a consistent relationship between overall mean LD(50) and plaques titre for all study preparations other than sample E. The slope of the correlation curve is >1 and it would appear that 10(3) LD(50) is approximately equivalent to 10(4) plaque forming units (PFU), based on the overall means of all laboratory results. The First International Standard for yellow fever vaccine, NIBSC Code 99/616, has been established as the First International Standard for yellow fever vaccine by the Expert Committee of Biological Standards of the World Health Organisation. The International Standard has been arbitrarily assigned a potency of 10(4.5) International Units (IU) per ampoule. Manufacturers and National Control Laboratories are including the First International Standard for yellow fever vaccine in routine assays so that the minimum potency in IU of vaccines released for use and which meet the current minimum potency of 10(3) LD(50) in mouse assays, can be determined. These data will be analysed before a review of the WHO requirements, including the minimum potency per dose, is undertaken.  相似文献   

6.
A collaborative study was carried out to establish a replacement for the International Standard for Rabies Vaccine, the stocks of which are exhausted. Three rabies vaccines for human use derived from different rabies virus strains and prepared on different cell culture substrates were compared with the International Standard for Rabies Vaccine using in vivo and in vitro assay methods in a collaborative study involving 14 participants. The proposed fifth International Standard (PISRAV) which was derived from the same virus strain as the present international standard preparation, the Pitman Moore (PM) strain, was found to be approximately twice as potent relative to the International Standard in immunogenicity assays as in antigenicity assays. On the other hand another vaccine, derived from the LEP strain, was considerably more potent in antigenicity assays than in immunogenicity assays. The glycoprotein of the proposed replacement standard measured in antigenicity assays appeared to be stable at +37 degrees C for 245 days, whereas the immunogenicity of the proposed replacement vaccine was sensitive to this heat treatment and the vaccine lost 66% of its immunogenic potency. The results of this study indicate that the NIH protection test should continue to form the primary basis for potency assay of rabies vaccine as glycoprotein content does not appear to correlate with immunogenic potency for different types of vaccine. The vaccine coded PISRAV has been established as the fifth International Standard for Rabies Vaccine and a potency of 16 International Units of Rabies Vaccine (based on the immunogenicity assays) assigned to the contents of each ampoule. Each ampoule has also been assigned a unitage of 10 IU of PM Rabies Virus Glycoprotein and 135 IU of PM Rabies Virus Ribonucleoprotein.  相似文献   

7.
We report here the characterisation of a preparation of diphtheria toxoid, adsorbed, and its calibration by twenty laboratories in fourteen countries in terms of the Second International Standard (I.S.) for Diphtheria Toxoid, Adsorbed, coded sample A (DIXA) using the established World Health Organisation (WHO)/European Pharmacopoeia (Ph Eur) challenge methods. The replacement standard preparation was found to have a unitage of 160 IU/ampoule on the basis of its calibration by in vivo bioassay. Stability was assessed within the collaborative study, and as part of candidate characterisation. Results suggest that the replacement standard will have satisfactory stability. This study also provided an opportunity to investigate serology as alternative to in vivo bioassay for potency testing of diphtheria vaccines. Six laboratories participated by performing serology according to in-house protocol. The calibration of the replacement standard in a mouse Vero cell assay gave a significantly higher results than in the established WHO/Ph Eur methods. Based on the results of this study and with the agreement of participants, the candidate standard was established as the Third International Standard for Diphtheria Toxoid, Adsorbed (coded 98/560) by the WHO Expert Committee of Biological Standardization in October 1999. The same preparation was also established as the second Ph Eur Biological Reference Preparation (Ph Eur BRP, batch no. 3) by the Steering Committee of the Biological Standardisation Programme of the European Directorate for the Quality of Medicines and approved by the European Pharmacopoeia Commission.  相似文献   

8.
Here we report the characterisation of a preparation of tetanus toxoid, adsorbed, and its calibration by 27 laboratories in 19 countries in a joint international collaborative study co-sponsored by World Health Organization (WHO) Expert Committee of Biological Standardization (ECBS) and the European Biological Standardisation Programme of European Directorate for the Quality of Medicines (EDQM), Council of Europe. Calibration was in terms of the Second International Standard (I.S.) for Tetanus Toxoid, Adsorbed, by the established WHO/European Pharmacopoeia (Ph Eur) challenge methods. The replacement standard preparation was found to have a unitage of 469 IU/ampoule on the basis of its calibration in guinea-pigs and 496 IU/ampoule on the basis of its calibration in mice. Assessment, both within the collaborative study and as part of candidate characterisation, indicated satisfactory stability of the candidate preparation. This study also provided some information on the effect of mouse strain on potency testing of tetanus vaccines. A limited assessment of the impact of the replacement standard on testing of current production batches of vaccines was also carried out by four manufacturers. This study did not directly address the serological approaches to potency testing. However, one laboratory offered data from mouse serology assay, which gave comparable estimates to in vivo mouse bioassay.Based on the results of this study and with the agreement of participants, the candidate standard was established as the Third International Standard for Tetanus Toxoid, Adsorbed (coded 98/552) by the WHO Expert Committee of Biological Standardization (ECBS) in November 2000. The same preparation was also established as the second Ph Eur Biological Reference Preparation (Ph Eur BRP, batch no. 2) by the Steering Committee of the Biological Standardisation Programme of the EDQM and approved by the European Pharmacopoeia Commission.  相似文献   

9.
We present the results of a collaborative study for the establishment of a replacement International Standard (IS) for Tetanus Toxoid Adsorbed. Two candidate preparations were included in the study, one of which was established as the 4th IS for Tetanus Toxoid Adsorbed at the WHO Expert Committee on Biological Standardization meeting in October 2010. This preparation was found to have a unitage of 490 IU/ampoule, based on calibration in guinea pig challenge assays. Results from mouse challenge assays suggest that the relative performance of two candidate preparations may differ significantly between guinea pigs and mice. The authors note that the number of laboratories that performed guinea pig challenge assays, which are used to calibrate and assign IU, is much lower than in previous collaborative studies and this may have implications for calibration of replacement standards in the future. The issue of assigning separate units to the IS for guinea pig and mouse assays is discussed. The study also assessed performance of the replacement standard in serological assays which are used as alternative procedures to challenge assays for tetanus potency testing. Results suggest that the replacement standard is suitable for use as the reference vaccine in serological assays.  相似文献   

10.
A collaborative study was carried out to assess the suitability of a candidate replacement material for the International Standard for hepatitis A immunoglobulin, which was found to be reactive for HCV RNA, and to calibrate it in International Units. The candidate standard, coded 97/646, was derived from a bulk of 16% immunoglobulin supplied by the Central Laboratory of the Netherlands Red Cross, Amsterdam, and diluted 1 in 2 in H2O resulting in a final immunoglobulin concentration of 8%. Sixteen laboratories from 11 countries participated in the study and contributed data from 64 assays performed using six commercial assay kits and four in-house methods. All assays were analysed as parallel line bioassays comparing assay response with log concentration. The overall mean potency of the candidate replacement immunoglobulin standard, 97/646, relative to the International Standard for hepatitis A immunoglobulin, was 98.6 IU/ml. A freeze-dried serum preparation, 97/648, was also calibrated in this study and had a potency of 22.64 IU/ml. The Second International Standard for hepatitis A immunoglobulin, human, was established by the World Health Organisation Expert Committee on Biological Standardisation in 1998 with a potency of 49 IU per ampoule when reconstituted in 0.5 ml.  相似文献   

11.
A preparation of somatropin (recombinant DNA-derived human growth hormone) was prepared as lyophilised ampoules according to WHO procedures for international biological standards. The candidate preparation (98/574) was evaluated in an international collaborative study (16 laboratories, nine countries), with the following aims: (i) to determine the suitability of the preparation to serve as the International Standard for somatropin by studying its performance in the current range of physico-chemical and biological assay methods employed for somatropin; (ii) to assign a content in terms of the existing (first) International Standard for somatropin, using the currently recognised assay procedure (Size Exclusion High Performance Liquid Chromatography, SE HPLC); (iii) to confirm the specific biological activity of the candidate preparation; (iv) to confirm the stability of the candidate preparation. On the basis of the collaborative study WHO agreed that: the preparation in ampoules coded 98/574 is suitable to serve as the next WHO International Standard for somatropin; the preparation in ampoules coded 98/574 should be established as the second International Standard for somatropin, with a defined ampoule content of 1.95 mg total somatropin plus somatropin-related proteins per ampoule; the specific activity of the preparation should be defined as 3.0 IU/mg somatropin.  相似文献   

12.
The 1st International Standard for Diphtheria Antitoxin Human (coded 10/262) was established by the World Health Organization Expert Committee on Biological Standardization in 2012. This paper describes the production, characterization and calibration of the new standard which is intended for use in the standardization of assays used to measure diphtheria antibody responses in human serum. The new standard was calibrated in terms of the International Standard for Diphtheria Antitoxin Equine in an international collaborative study. A total of 8 participants from 8 different countries performed in vivo and/or in vitro toxin neutralization tests and returned data that was used to assign units to the proposed new standard. The new standard has a diphtheria antitoxin potency of 2 IU/ampoule and is predicted to be stable. A follow up study was performed to assess commutability of the new standard. The follow up study was an existing external quality assessment, modified to include the new standard. Results obtained suggest that the new standard is commutable, showing comparable behaviour to native human serum samples in the majority of the assays compared, and is therefore suitable for use as a reference preparation in assays used to measure the level of anti-diphtheria antibodies in human serum.  相似文献   

13.
We present the results of a collaborative study for the characterization of a preparation of diphtheria toxoid adsorbed, and its calibration in terms of the 3rd International Standard (IS) for Diphtheria Toxoid Adsorbed. Calibration was performed using established World Health Organization (WHO) and European Pharmacopoeia (Ph. Eur.) protection models. Two candidate toxoid preparations were included in the study, one of which was adopted as a replacement Ph. Eur. Biological Reference Preparation (BRP, batch 4) in February 2009. The second candidate preparation was found to have a unitage of 213 IU/ampoule based on the calibration by in vivo bioassay in 19 laboratories in 16 countries, and was established as the 4th IS for Diphtheria Toxoid Adsorbed by the WHO Expert Committee on Biological Standardization (ECBS) in October 2009.The study also assessed performance of the replacement standard in mouse and guinea pig serological assays which are used as alternative procedures for diphtheria potency testing. Participants tested both candidate preparations and potency was expressed in relative terms only. Results suggest that the replacement standard is suitable for use as the reference vaccine in serological assays and that the Vero cell assay may be suitable for calibration of future replacement standards.  相似文献   

14.
A collaborative study was conducted to establish a suitable international reference reagent for hepatitis B vaccine for use in immunogenicity assays. The limiting dilution required to induce antibodies in 50% of the test animals was determined for the proposed international reference reagent and three other plasma-derived hepatitis B vaccines. The minimum antigenic dose of these preparations varied widely (100-fold range) between laboratories. However, the expression of potencies of vaccines relative to the proposed International Reference Reagent reduced the variation between laboratories to within a 10-fold range. The reference reagent is intended for use in assays of hepatitis B vaccines in mouse (or guinea-pig) immunogenicity studies. For products made by different procedures, clinical trials in humans are necessary to establish a correlation between the immunogenic potency in animals and man.  相似文献   

15.
The 4th International Standard (IS) for Insulin, established in 1958, consists of a mixture of relatively impure bovine and porcine insulins and is not suitable as a standard for the assay of highly purified single-species insulins presently used in the treatment of diabetes. Preparations of human, bovine and porcine crystalline insulins, representative of current highly purified therapeutic insulins, have now been studied in an international collaborative study carried out by twenty-three laboratories in fifteen countries. In the collaborative study described here, each of the three preparations was found to be suitable for use as a standard for insulin for bioassay and each was established by WHO in 1986 as an international standard. The 4th IS of Insulin bovine/porcine (code numbered 58/6) has been discontinued. Insulin preparations should now be calibrated in terms of International Units defined by the standard for the appropriate species: the International Standard for Insulin, Human, the International Standard for Insulin, Bovine, or the International Standard for Insulin, Porcine.  相似文献   

16.
A collaborative study was undertaken to assess the suitability of a replacement for the First International Standard for parvovirus B19 IgG, human serum and to calibrate it in IU. The proposed standard, which is a pool of sera from 16 US blood donors, was assayed along with the First International Standard, a coded duplicate of the proposed standard and a plasma sample from a single blood donor. Nine laboratories from eight countries participated in the studies and five different assay kits were used. Two kits contained VP1+VP2, one kit contained VP1 only and two kits, one of which was used by five participants contained VP2 only. Differences in detection of the proposed standard and the individual plasma were observed with assay kits containing different antigens, VP1, VP2 or VP1+VP2. However, since VP1 is a minor capsid protein and on its own does not assemble into virus like particles and the dominant response in individuals appears to be against VP2, it was considered reasonable to utilize only the data from kits containing VP2 antigen for the calibration of the proposed standard. The results of this study demonstrated that the proposed standard coded 01/602 was suitable to serve as the replacement International Standard for parvovirus B19, serum IgG, and this preparation was established as the Second International Standard for parvovirus B19 antibody, plasma human, with an assigned unitage of 77 IU per ampoule by the Expert Committee on Biological Standardisation of the World Health Organisation in February 2003.  相似文献   

17.
The International Reference Preparation of Kanamycin has been replaced by the International Standard for Kanamycin. The potency of the standard is based upon a collaborative study in ten laboratories in ten countries. Each ampoule of the International Standard of Kanamycin is defined as containing the activity of 10345 International Units of Kanamycin.  相似文献   

18.
The single radial immunodiffusion (SRD) technique has been applied to the assay of the glycoprotein content of rabies vaccines produced in cell cultures. Fourteen laboratories in seven countries participated in a collaborative study to evaluate the reproducibility of the SRD technique; some laboratories also examined vaccines in the mouse protection (NIH) test and by enzyme immunoassay. Good agreement was found between potency estimates using the SRD technique: the geometric coefficients of variation for combined potency estimates of all laboratories were about 10%. SRD assays appear to have a role for the in vitro assay of antigen content of vaccine and could complement results obtained in in vivo assays which are subject to wide variability.  相似文献   

19.
D J Wood  A B Heath 《Biologicals》1992,20(4):293-300
A serology panel was used to assess the comparability of results of poliovirus neutralizing antibody assays. Five laboratories from three countries provided results with seven in-house methods. A high degree of within-laboratory reproducibility was seen for all laboratories and methods, with 94% of results for repeat titrations within plus or minus one twofold dilution. Considerable differences in sensitivity between methods were, however, observed. The period of serum/virus incubation prior to inoculation of cells was shown by one laboratory to have a 10-fold effect on titres, and another laboratory showed that use of Sabin or wild-type challenge virus significantly influenced results for types 1 and 3. Expression of results as relative potencies abolished these difference due to method. The difference in sensitivity between laboratories for end-point titres (if one very sensitive method was excluded) was around fourfold for types 1 and 2, and ninefold for type 3. This range increased to 15-fold for type 2; and 20-fold for types 1 and 3 if the most sensitive method was included. Expression of results relative to a standard considerably improved agreement with a residual variation of around fourfold. Therefore, expression of results from serological studies, including vaccine trials, in International Units (i.e. relative to the new International Standard) will assure that comparisons between studies can be made with confidence.  相似文献   

20.

Background

During a citywide epidemic of serogroup C meningococcal disease in Salvador in 2010, Brazil, the state government initiated mass vaccination targeting two age groups with high attack rates: individuals aged <5 years and 10–24 years. More than 600,000 doses of meningococcal serogroup C conjugate vaccines were administered. We performed a case-control study to evaluate vaccine uptake, document vaccine effectiveness and identify reasons for non-vaccination.

Methods and Findings

Population-based surveillance identified patients with laboratory-confirmed invasive meningococcal C (MenC) disease during 2010. Information on MenC vaccination was obtained from case patients and age-matched individuals from the same neighborhoods. MenC vaccine effectiveness was estimated based on the exact odds ratios obtained by conditional logistic regression analysis. Of 51 laboratory-confirmed cases of serogroup C meningococcal disease among patients <5 and 10–24 years of age 50 were included in the study and matched with 240 controls. Overall case-fatality was 25%. MenC vaccine coverage among controls increased from 7.1% to 70.2% after initiation of the vaccination campaign. None of the 50 case patients but 70 (29.2%) of the 240 control individuals, including 59 (70.2%) of 84 matched with cases from the period after MenC vaccination, had received at least one MenC vaccine dose. Overall effectiveness of MenC was 98% with a lower 95% exact confidence limit of 89%.

Conclusions

MenC vaccines administered during the meningococcal epidemic were highly effective, suggesting that rapid vaccine uptake through campaigns contributed to control of meningococcal disease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号