首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
A high throughput protein biomarker discovery tool has been developed based on multiplexed proximity ligation assays in a homogeneous format in the sense of no washing steps. The platform consists of four 24-plex panels profiling 74 putative biomarkers with sub-pm sensitivity each consuming only 1 μl of human plasma sample. The system uses either matched monoclonal antibody pairs or the more readily available single batches of affinity purified polyclonal antibodies to generate the target specific reagents by covalently linking with unique nucleic acid sequences. These paired sequences are united by DNA ligation upon simultaneous target binding forming a PCR amplicon. Multiplex proximity ligation assays thereby converts multiple target analytes into real-time PCR amplicons that are individually quantified using microfluidic high capacity qPCR in nano liter volumes. The assay shows excellent specificity, even in multiplex, by its dual recognition feature, its proximity requirement, and most importantly by using unique sequence specific reporter fragments on both antibody-based probes. To illustrate the potential of this protein detection technology, a pilot biomarker research project was performed using biobanked plasma samples for the detection of colorectal cancer using a multivariate signature.  相似文献   

3.
4.
To prevent and treat immune-mediated platelet disorders (e.g. neonatal allo-immune thrombocytopenia and platelet transfusion refractoriness) the causative idiotypic platelet-reactive antibodies have to be detected with high sensitivity and specificity. The "Monoclonal Antibody Immobilization Platelet Assay" (MAIPA) is the diagnostic gold standard for immunotyping sera with respect to alloantibodies against human platelet antigens (HPA). However, it is labor-intensive and time-consuming. In this work, an automated protein chip assay (enzyme-linked sandwich immunoassay) based on interdigitated gold microelectrodes in combination with an electrical read-out system was developed and optimized. For this purpose, specific capture antibodies were immobilized on the gold electrodes. The binding of the target is detected via an enzyme-labeled detection antibody by a redox-recycling process that corresponds to the amount of bound target molecule. With this electrical chip assay it is possible to detect antibodies against HPA-1a, HPA-5b and HLA with high sensitivity and specificity in less than half the duration of the MAIPA protocol with similar intra- and interassay variance.  相似文献   

5.
The inability to quantify large numbers of proteins in tissues and biofluids with high precision, sensitivity, and throughput is a major bottleneck in biomarker studies. We previously demonstrated that coupling immunoaffinity enrichment using anti-peptide antibodies (SISCAPA) to multiple reaction monitoring mass spectrometry (MRM-MS) produces Immunoprecipitation MRM-MS (immuno-MRM-MS) assays that can be multiplexed to quantify proteins in plasma with high sensitivity, specificity, and precision. Here we report the first systematic evaluation of the interlaboratory performance of multiplexed (8-plex) immuno-MRM-MS in three independent labs. A staged study was carried out in which the effect of each processing and analysis step on assay coefficient of variance, limit of detection, limit of quantification, and recovery was evaluated. Limits of detection were at or below 1 ng/ml for the assayed proteins in 30 μl of plasma. Assay reproducibility was acceptable for verification studies, with median intra- and interlaboratory coefficients of variance above the limit of quantification of 11% and <14%, respectively, for the entire immuno-MRM-MS assay process, including enzymatic digestion of plasma. Trypsin digestion and its requisite sample handling contributed the most to assay variability and reduced the recovery of target peptides from digested proteins. Using a stable isotope-labeled protein as an internal standard instead of stable isotope-labeled peptides to account for losses in the digestion process nearly doubled assay accuracy for this while improving assay precision 5%. Our results demonstrate that multiplexed immuno-MRM-MS can be made reproducible across independent laboratories and has the potential to be adopted widely for assaying proteins in matrices as complex as plasma.  相似文献   

6.
In this study, a simple TAMRA (tetramethyl-6-carboxyrhodamine) quenching-based aptasensing platform was designed for the detection of aflatoxin B1 (AFB1). Here, we compared the analytical performance of two aptamer sequences: seqA and seqB. The AFB1 detection was based on the interactions of FAM (carboxyfluorescein)-labeled aptamer with TAMRA-labeled DNA complementary strand in the presence and absence of target analyte. Under optimized experimental conditions, TAMRA-labeled strand quenched the fluorescence response of FAM-labeled aptamer due to the noncovalent interaction between the two DNA strands. The binding of AFB1 induced the complex formation and weakened the interaction between FAM-labeled aptamer and TAMRA-labeled complementary strand, resulting in the fluorescence recovery. By using this principle concept, an assay was constructed for the detection of AFB1. The method exhibited good sensitivity, good selectivity with a limit of detection of 0.2 ng ml−1, and a wide linear range from 0.25 to 32 ng ml−1. For real sample application, the aptasensors were tested in beer and wine samples, with good recovery rates obtained for AFB1 detection.  相似文献   

7.
8.
Partyka K  Maupin KA  Brand RE  Haab BB 《Proteomics》2012,12(13):2212-2220
The CA 19-9 antigen is currently the best individual marker for the detection of pancreatic cancer. In order to optimize the CA 19-9 assay and to develop approaches to further improve cancer detection, it is important to understand the specificity differences between CA 19-9 antibodies and the consequential affect on biomarker performance. Antibody arrays enabled multiplexed comparisons between five different CA 19-9 antibodies used in the analysis of plasma samples from pancreatic cancer patients and controls. Major differences were observed between antibodies in their detection of particular patient samples. Glycan array analysis revealed that certain antibodies were highly specific for the canonical CA 19-9 epitope, sialyl-Lewis A, while others bound sialyl-Lewis A in addition to a related structure called sialyl-Lewis C and modification with Nue5Gc. In a much larger patient cohort, we confirmed the binding of sialyl-Lewis C glycan by one of the antibodies and showed that the broader specificity led to the detection of an increased number of cancer patients without increasing detection of pancreatitis patient samples. This work demonstrates that variation between antibody specificity for cancer-associated glycans can have significant implications for biomarker performance and highlights the value of characterizing and detecting the range of glycan structures that are elevated in cancer.  相似文献   

9.
Inhibitory antibodies directed against coagulation factor VIII (FVIII) can be found in patients with acquired and congenital hemophilia A. Such FVIII-inhibiting antibodies are routinely detected by the functional Bethesda Assay. However, this assay has a low sensitivity and shows a high inter-laboratory variability. Another method to detect antibodies recognizing FVIII is ELISA, but this test does not allow the distinction between inhibitory and non-inhibitory antibodies. Therefore, we aimed at replacing the intricate antigen FVIII by Designed Ankyrin Repeat Proteins (DARPins) mimicking the epitopes of FVIII inhibitors. As a model we used the well-described inhibitory human monoclonal anti-FVIII antibody, Bo2C11, for the selection on DARPin libraries. Two DARPins were selected binding to the antigen-binding site of Bo2C11, which mimic thus a functional epitope on FVIII. These DARPins inhibited the binding of the antibody to its antigen and restored FVIII activity as determined in the Bethesda assay. Furthermore, the specific DARPins were able to recognize the target antibody in human plasma and could therefore be used to test for the presence of Bo2C11-like antibodies in a large set of hemophilia A patients. These data suggest, that our approach might be used to isolate epitopes from different sets of anti-FVIII antibodies in order to develop an ELISA-based screening assay allowing the distinction of inhibitory and non-inhibitory anti-FVIII antibodies according to their antibody signatures.  相似文献   

10.
Padlock probes (PLPs) are long oligonucleotides, whose ends are complementary to adjacent target sequences. Upon hybridization to the target, the two ends are brought into contact, allowing PLP circularization by ligation. PLPs provide extremely specific target recognition, which is followed by universal amplification and microarray detection. Since target recognition is separated from downstream processing, PLPs enable the development of flexible and extendable diagnostic systems, targeting diverse organisms. To adapt padlock technology for diagnostic purposes, we optimized PLP design to ensure high specificity and eliminating ligation on non-target sequences under real-world assay conditions. We designed and tested 11 PLPs to target various plant pathogens at the genus, species and subspecies levels, and developed a prototype PLP-based plant health chip. Excellent specificity was demonstrated toward the target organisms. Assay background was determined for each hybridization using a no-target reference sample, which provided reliable and sensitive identification of positive samples. A sensitivity of 5 pg genomic DNA and a dynamic range of detection of 100 were observed. The developed multiplex diagnostic system was validated using genomic DNAs of characterized isolates and artificial mixtures thereof. The demonstrated system is adaptable to a wide variety of applications ranging from pest management to environmental microbiology.  相似文献   

11.

Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.

  相似文献   

12.
Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.  相似文献   

13.
14.
A sensitive and selective genomagnetic assay for the electrochemical detection of food pathogens based on in situ DNA amplification with magnetic primers has been designed. The performance of the genomagnetic assay was firstly demonstrated for a DNA synthetic target by its double-hybridization with both a digoxigenin probe and a biotinylated capture probe, and further binding to streptavidin-modified magnetic beads. The DNA sandwiched target bound on the magnetic beads is then separated by using a magneto electrode based on graphite-epoxy composite. The electrochemical detection is finally achieved by an enzyme marker, anti-digoxigenin horseradish peroxidase (HRP). The novel strategy was used for the rapid and sensitive detection of polymerase chain reaction (PCR) amplified samples. Promising resultants were also achieved for the DNA amplification directly performed on magnetic beads by using a novel magnetic primer, i.e., the up PCR primer bound to magnetic beads. Moreover, the magneto DNA biosensing assay was able to detect changes at single nucleotide polymorphism (SNP) level, when stringent hybridization conditions were used. The reliability of the assay was tested for Salmonella spp., the most important pathogen affecting food safety.  相似文献   

15.
An enzyme capture assay for analysis of active hyaluronan synthases   总被引:1,自引:0,他引:1  
We describe a sensitive assay for detection of active hyaluronan synthases (HASs) capable of synthesizing hyaluronan (HA) without use of radioactive uridine 5'-diphosphate sugar precursors. The HAS capture assay is based on the binding of a biotinylated HA binding protein (bHABP) to HA chains that are associated with HAS and the subsequent capture of bHABP-HA-HAS complexes with streptavidin-agarose. Specific HAS proteins (e.g., HAS1, not HAS2 or HAS3) captured in this pull-down approach are readily immunodetected by Western blot analysis using appropriate antibodies. The assay was used to detect active HAS proteins in cell membranes, purified recombinant Streptococcus equisimilis HAS (SeHAS), and in vitro translated human HAS1 or SeHAS. The HAS capture assay was also used to assess the fraction of HAS molecules that were active, which cannot be done using standard assays for synthase activity. Assay sensitivity for detection of purified SeHAS is <1 pmol.  相似文献   

16.
A novel cascade fluorescence signal amplification strategy based on the rolling circle amplification (RCA)-aided assembly of fluorescent DNA nanotags as fluorescent labels and multiplex binding of the biotin-streptavidin system was proposed for detection of protein target at ultralow concentration. In the strategy, fluorescent DNA nanotags are prepared relying on intercalating dye arrays assembled on nanostructured DNA templates by intercalation between base pairs. The RCA product containing tandem-repeat sequences could serve as an excellent template for periodic assembly of fluorescent DNA nanotags, which were presented per protein recognition event to numerous fluorescent DNA nanotags for assay readout. Both the RCA and the multiplex binding system showed remarkable amplification efficiency, very little nonspecific adsorption, and low background signal. Using human IgG as a model protein, the designed strategy was successfully demonstrated for the ultrasensitive detection of protein target. The results revealed that the strategy exhibited a dynamic response to human IgG over a three-decade concentration range from 1.0 pM to 1.0 fM with a limit of detection as low as 0.9 fM. By comparison with the assay of multiple labeling antibodies with the dye/DNA conjugate, the limit of detection was improved by 4 orders. The designed signal amplification strategy would hold great promise as a powerful tool to be applied for the ultrasensitive detection of target protein in immunoassay.  相似文献   

17.
A method for measuring the amount of a nonradiolabeled DNA probe using four detection substrates is described. In preliminary experiments, digoxygenin-labeled DNA was bound to neutral, nylon membranes and detected with anti-digoxygenin antibodies conjugated to alkaline phosphatase. Four substrates [4-nitrophenyl phosphate, 4-methylumbelliferyl phosphate, AttoPhos, and adamantyl 1, 2-dioxetane phosphate (AMPPD)] were assessed for use in a quantitative hybridization assay. Only AttoPhos and AMPPD were found to have detection limits in the low picogram range and to respond linearly to DNA concentrations ranging from 0 to 1250 pg. In subsequent experiments, a 200-bp DNA probe cloned from the marine bacterium Pseudomonas perfectomarina 23S rRNA gene was hybridized to P. perfectomarina genomic DNA and total RNA. The amount of hybridized probe was determined using AttoPhos. Finally, a digoxygenin-labeled oligonucleotide was probed against genomic DNA. Linearity with respect to DNA concentration was observed using both the 200-bp fragment and the oligonucleotide as probes with a final target detection limit of 166 fg. This study demonstrates the substrate AttoPhos can be used to quantify the amount of nonradiolabeled probe hybridized to target with sufficient sensitivity for very dilute samples, such as environmental samples.  相似文献   

18.
The human polyomavirus BK (BKV) is wide-spread pathogen, associated with urogenital tract disorders or even nephropathy in immunosuppressed patients. Nowadays molecular detection by real-time PCR (qPCR) is recognized as a method-of-choice for detecting human polyomaviruses in clinical samples. The aim of the study was development of real-time PCR assay for detection and quantification of polyomavirus BK DNA in clinical samples, using specific primers targeting a viral DNA VP3 gene and a TaqMan hydrolyzing probe. The analytical sensitivity of assay was tested using serial dilutions of BKV DNA in range between 13500 and 15 copies/ml. 27 urine samples and 23 plasma samples taken from a group of 22 adult recipients of allogeneic HSCT were tested for the presence of polyomavirus BK in the LightCycler system. Described in-house real-time PCR assay detected BKV DNA in 8 specimens (6 urine and 2 plasma). Detected average viral load was 170 copies/ml for plasma and 1250 copies/ml for urine samples, respectively. The results of this study show that developed TaqMan-based probe qPCR assay is very reliable and valuable for detection and quantification of BKV DNA, both in urine and plasma samples. These data, combined with its rapid turnaround time for results and decreased hands-on time, make the LightCycler PCR assay highly suitable for the rapid diagnostics of polyomavirus BK infections in the clinical laboratory.  相似文献   

19.
Nucleic acid-based biochemical assays are crucial to modern biology. Key applications, such as detection of bacterial, viral and fungal pathogens, require detailed knowledge of assay sensitivity and specificity to obtain reliable results. Improved methods to predict assay performance are needed for exploiting the exponentially growing amount of DNA sequence data and for reducing the experimental effort required to develop robust detection assays. Toward this goal, we present an algorithm for the calculation of sequence similarity based on DNA thermodynamics. In our approach, search queries consist of one to three oligonucleotide sequences representing either a hybridization probe, a pair of Padlock probes or a pair of PCR primers with an optional TaqMantrade mark probe (i.e. in silico or 'virtual' PCR). Matches are reported if the query and target satisfy both the thermodynamics of the assay (binding at a specified hybridization temperature and/or change in free energy) and the relevant biological constraints (assay sequences binding to the correct target duplex strands in the required orientations). The sensitivity and specificity of our method is evaluated by comparing predicted to known sequence tagged sites in the human genome. Free energy is shown to be a more sensitive and specific match criterion than hybridization temperature.  相似文献   

20.
The possible diagnostic or prognostic significance of changes in circulating level of endothelins in a variety of pathological conditions is currently of interest. Unfortunately, no consensus regarding optimization of sensitivity and extraction procedures for the reliable radioimmunoassay of endothelin-1 (ET-1), big endothelin-1 (BigET-1), and endothelin-3 (ET-3) currently exists. The object of the present study was to evaluate aspects of currently used extraction and assay procedures that limit accurate determination of ET in human plasma and define criteria to reduce variability. Critical parameters include the selectivity of commercial antibodies and the ability to remove interfering material after Sep-Pak absorption by selective washing with 24% ethanol in 4% acetic acid or methylene chloride in 0.1% trifluoroacetic acid. Assay sensitivity and specificity in the physiological range is improved by optimizing total binding parameters for the antibodies to give approximately 15-20% binding of radiolabeled peptide. With these modifications normal plasma values for ET-1, BigET-1, and ET-3 averaged 1.7 +/- 0.06, 2.5 +/- 0.3, and 5.8 +/- 0.2 pg/ml, respectively. These data suggest that such modifications may help to resolve many of the earlier difficulties concerning the role of ET under normal and pathological conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号