首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A methodology has been developed and validated for the simultaneous quantitation of O6-methyl- and 7-methylguanine in DNA isolated from in vitro exposure to the model alkylating agents: N-methyl-N-nitrosourea (MNU) and methyl methane sulfonate (MMS). After exposure, DNA was isolated and directly hydrolyzed under acid conditions to hydrolytes containing DNA bases (modified and unmodified). The hydrolytes were used for direct O6- and 7-methylguanine quantitation using a rapid and selective liquid chromatography-electrospray tandem mass spectrometry (LC/ESI-MS/MS). The lower limits of quantitation for O6-methyl- and 7-methylguanine were 75.8 and 151.5 fmol, respectively. Linearity of the calibration curve was greater than 0.999 from 75.8 to 151,600.0 fmol for O6-methylguanine and 0.999 from 151.5 to 303,200.0 fmol for 7-methylguanine. The intra-day assay precision relative standard deviation (R.S.D.) values for O6-methylguanine for quality control (QC) samples were < or =9.2% with accuracy values ranging from 90.8 to 118%, and for 7-methylguanine the R.S.D. values for QC samples were < or =11%, with accuracy values ranging from 92.9 to 119%. The inter-day assay precision (R.S.D.) values for O6-methylguanine QC samples were < or =7.9% with accuracy values ranging from 94.5 to 116%, and for 7-methylguanine QC samples were < or =7.1% with accuracy values ranging from 95.2 to 110.2%. This method was used for simultaneous determination of the levels of 7-methyl- and O6-methylguanine in DNA acidic hydrolytes present in a series of incubations from salmon testis DNA treated with either MNU or MMS.  相似文献   

2.
PM01218 is a novel marine-derived alkaloid and has shown potent growth inhibitory activity against several human cancer cell lines. A rapid and sensitive high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method was developed and validated to quantify PM01218 in mouse and rat plasma. The lower limit of quantitation (LLOQ) was 0.05 ng/mL. The calibration curve was linear from 0.05 to 100 ng/mL (R(2)>0.999). The assay was specifically based on the multiple reaction monitoring (MRM) transitions at m/z 278.4-->184.2, no endogenous material interfaced with the analysis of PM01218 and its internal standard from blank mouse and rat plasma. The mean intra- and inter-day assay accuracy remained below 15 and 8%, respectively, for all calibration standards and QC samples. The intra- and inter-day assay precision was less than 12.8 and 8.5% for all QC levels, respectively. The utility of the assay was demonstrated by pharmacokinetics studies of i.v. (bolus) PM01218 on SD rats.  相似文献   

3.
In the present work, a high-throughput LC/MS/MS method using a Chromolith RP-18 (50 mm x 4.6 mm) monolithic column was developed and partially validated for the determination of bupropion (BUP), an anti-depressant drug, and its metabolites, hydroxybupropion and threo-hydrobupropion (TB), in human, mouse, and rat plasma. A modern integrated liquid chromatograph and an LC/MS/MS system with a TurboIonSpray (TIS) interface were used for the positive electrospray selected reaction monitoring (SRM) LC/MS analyses. Spiked control plasma calibration standards and quality control (QC) samples were extracted by semi-automated 96-well liquid-liquid extraction (LLE) using ethyl acetate. A mobile phase consisting of 8mM ammonium acetate-acetonitrile (55:45, v/v) delivered isocratically at 5 ml/min, and split post-column to 2 ml/min directed to the TIS, provided the optimum conditions for the chromatographic separation of bupropion and its metabolites within 23s. The isotope-labeled D(6)-bupropion and D(6)-hydroxybupropion were used as internal standards. The method was linear over a concentration range of 0.25-200 ng/ml (bupropion and threo-hydrobupropion), and 1.25-1000 ng/ml (hydroxybupropion). The intra- and inter-day assay accuracy and precision were within 15% for all analytes in each of the biological matrices. The monolithic column performance as a function of column backpressure, peak asymmetry, and retention time reproducibility was adequately maintained over 864 extracted plasma injections.  相似文献   

4.
Liquid chromatography (LC) in direct combination with mass spectrometry (MS) has been shown to be a good analytical technique for the selective separation and detection of labile folate monoglutamates. Reversed-phase LC and electrospray-ionization MS conditions were developed and optimized for the separation and detection of 5-methyltetrahydrofolic acid, 5-formyl tetrahydrofolic acid, tetrahydrofolic acid, dihydrofolic acid and folic acid in aqueous samples. Representative and reproducible positive ion mass spectra were generated for each folate under mild MS conditions. The selective MS detection and identification of endogenous 5-methyltetrahydrofolic acid in human plasma was accomplished through the development of a straightforward C18-based solid-phase extraction procedure. This procedure allows for the qualitative assessment of 5-methyltetrahydrofolic acid in plasma. Based upon an isotope-dilution internal standard calibration study with standards, the LC–MS limit of quantitation for 5M-THF was estimated to be 0.39 ng/ml.  相似文献   

5.
A sensitive and high throughput off-line μElution 96-well solid-phase extraction (SPE) followed by strong cation exchange (SCX) liquid chromatography with tandem mass spectrometry (LC/MS/MS) quantification for determination of cefepime has been developed and validated in mouse plasma. Using the chemical analog, ceftazidime as an internal standard (IS), the linear range of the method for the determination of cefepime in mouse plasma was 4–2048 ng/mL with the lower limit of quantitation level (LLOQ) of 4 ng/mL. The inter- and intra-assay precision and accuracy of the method were below 9.05% and ranged from 95.6 to 113%, respectively, determined by quality control (QC) samples at five concentration levels including LLOQ. After μElution SPE, 71.1% of cefepime was recovered. The application of the validated assay for the determination of cefepime in mouse pharmacokinetics (PK) samples after intravenous (IV) and subcutaneous (SC) doses was demonstrated.  相似文献   

6.
Ultrafiltration of human plasma in combination with LC-MS/MS has been increasingly used in the quantitative analysis of the free fraction of drug candidates for PK/efficacy assessment. In addition to controlling the pre-incubation and centrifugation temperatures, some important factors that must be investigated and addressed include: (1) possible nonspecific binding, (2) possible impact of freeze/thaw cycles of plasma samples and extended storage of plasma samples at room temperature on the analyte recovery prior to ultrafiltration, and (3) identification of the appropriate assay dynamic range to avoid unnecessary dilutions. These factors were explored in the development and validation of a robust LC-MS/MS assay for the quantitative analysis of unbound vadimezan (ASA404) in human plasma. First, to mimic human physiological conditions, all plasma samples were incubated at ~37°C for a minimum of 30 min after thawing and prior to centrifugation to obtain the ultrafiltrate. Second, by passing the calibration standards and QC samples in plasma ultrafiltrate through the ultrafiltration membrane, the observed non-specific binding of the analyte due to the membrane was corrected. Third, the effects of multiple freeze/thaw cycles and/or storage at room temperature for various periods (4, 8, 16 and 24h) were evaluated to determine the impact on analyte concentrations in the ultrafiltrate from the plasma QC samples. Fourth, the appropriate dynamic range was established to accommodate the expected incurred sample free analyte concentrations. The validated assay has a dynamic range of 30.0-30,000 ng/ml for ASA404 in human plasma ultrafiltrate using a sample volume of 30 μl. Quality control pools containing the analyte were prepared at concentrations of 30.0-22,500 ng/ml to cover the assay calibration range. The intra-assay and inter-assay precision and accuracy were ≤ 15% (CV) and within ± 15% (bias) of the nominal values, respectively, for all measured QC concentrations, including the LLOQ. Freeze/thaw for up to three cycles of the plasma samples and/or the extended human plasma sample exposure to room temperature for up to 24h were confirmed to have no impact on the assay results for the free analyte. The validated method was successfully implemented to support clinical studies for the compound.  相似文献   

7.
8.
Plasma levels of 1,5-anhydroglucitol (1-deoxyglucose), a short-term marker of glycemic control, have been measured and used clinically in Japan since the early 1990s. Plasma levels of 1,5-anhydroglucitol are typically measured using either a commercially available enzymatic kit or GC/MS. A more sensitive method is needed for the analysis of 1,5-anhydroglucitol in urine, where levels are significantly lower than in plasma. We have developed a sensitive and selective LC/MS(3) assay utilizing hydrophilic interaction liquid chromatography and ion trap mass spectrometry for the quantitative determination of 1,5-anhydroglucitol in human urine. Diluted human urine samples were analyzed by LC/MS(3) using an APCI source operated in the negative ionization mode. Use of an ion trap allowed monitoring of MS(3) transitions for both 1,5-anhydroglucitol and the internal standard which provided sufficient selectivity and sensitivity for analysis from 50 microL of human urine. Quantitation of 1,5-anhydroglucitol levels in urine was accomplished using a calibration curve generated in water (calibration range 50 ng/mL to 10 microg/mL). Method ruggedness and reproducibility were evaluated by determining the intra- and inter-day accuracies and precision of the assay, as well as the bench-top and freeze-thaw stability. For both inter- and intra-assay evaluations, the accuracy of the assay was found to be acceptable, with the concentrations of all QCs tested not deviating more than 8% from theoretical. Four-hour bench-top and freeze-thaw stabilities were also evaluated; 1,5-anhydroglucitol was found to be stable at room temperature (<18% deviation from theoretical) and during 3 freeze-thaw cycles (<1% deviation from theoretical, except at the lowest QC level). The LC/MS(3) assay was then used to successfully determine the concentration of 1,5-AG in more than 200 urine samples from diabetic patients enrolled in a clinical study.  相似文献   

9.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

10.
Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC–MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the ‘non-specific loss’ of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC–MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the ‘non-specific binding’ of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. β-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of β-cyclodextrin to untreated urine samples does not recover the ‘lost’ analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200–20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from ?3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid–liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at ≤?60 °C and for at least 3 months when stored at ≤?60 °C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples.  相似文献   

11.
Successful embryo implantation and placentation depend on appropriate trophoblast invasion into the maternal endometrial stroma. Human chorionic gonadotropin (hCG) is one of the earliest embryo-derived secreted signals in the peripheral blood mononuclear cells (PBMC) that abundantly expresses hCG receptors. The aims of this study were to estimate the effect of human embryo–secreted hCG on PBMC function and investigate the role and underlying mechanisms of activated PBMC in trophoblast invasion. Blood samples were collected from women undergoing benign gynecological surgery during the mid-secretory phase. PBMC were isolated and stimulated with or without hCG for 0 or 24 h. Interleukin-1β (IL-1β) and leukemia inhibitory factor (LIF) expressions in PBMC were detected by enzyme-linked immunosorbent assay and real-time polymerase chain reaction (PCR). The JAR cell line served as a model for trophoblast cells and was divided into four groups: control, hCG only, PBMC only, and PBMC with hCG. JAR cell invasive and proliferative abilities were detected by trans-well and CCK8 assays and matrix metalloproteinase (MMP)-2 (MMP-2), MMP-9, vascular endothelial growth factor (VEGF), tissue inhibitor of metalloproteinase (TIMP)-1, and TIMP-2 expressions in JAR cells were detected by western blotting and real-time PCR analysis. We found that hCG can remarkably promote IL-1β and LIF promotion in PBMC after 24-h culture. PBMC activated by hCG significantly increased the number of invasive JAR cells in an invasion assay without affecting proliferation, and hCG-activated PBMC significantly increased MMP-2, MMP-9, and VEGF and decreased TIMP-1 and TIMP-2 expressions in JAR cells in a dose-dependent manner. This study demonstrated that hCG stimulates cytokine secretion in human PBMC and could stimulate trophoblast invasion.  相似文献   

12.
A sensitive, specific, accurate and reproducible analytical method employing a divalent cation chelating agent (disodium EDTA) for sample treatment was developed to quantitate reserpine in FVB/N mouse plasma. Samples pretreated with 40 μl of 2% disodium EDTA in water were extracted by a semi-automated 96-well liquid–liquid extraction (LLE) procedure to isolate reserpine and a structural analog internal standard (I.S.), rescinnamine, from mouse plasma. The extracts were analyzed by turbo ionspray liquid chromatography–tandem mass spectrometry (LC–MS–MS) in the positive ion mode. Sample preparation time for conventional LLE was dramatically reduced by the semi-automated 96-well LLE approach. The assay demonstrated a lower limit of quantitation of 0.02 ng/ml using 0.1-ml plasma sample aliquots. The calibration curves were linear from 0.02 to 10 ng/ml for reserpine. The intra- and inter-assay precision of quality control (QC) samples ranged from 1.75 to 10.9% for reserpine. The intra- and inter-assay accuracy of QC samples ranged from −8.17 to 8.61%. Reserpine and the I.S. were found to be highly bound to FVB/N mouse plasma protein. This is the first report of disodium EDTA employed as a special protein-bound release agent to recover protein-bound analytes from plasma. These matrix effects and the effects of pH in the HPLC mobile phase on the sensitivities of LC–MS–MS are discussed in this paper.  相似文献   

13.
Tacrolimus (FK506) is a potent immunosuppressant widely used for organ transplantation patients while diltiazem (DTZ), a calcium-channel inhibitor, is often used in renal transplantation patients to prevent post-transplant hypertension. However, DTZ has a significant pharmacokinetic interaction with FK506. In this study, a rapid and sensitive ammonium-adduct based liquid chromatography-tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the simultaneous determination of FK506 and DTZ in human whole blood using ascomycin as the internal standard (IS). After extraction of the whole blood samples by ethyl acetate, FK506, DTZ and the IS were subjected to LC/MS/MS analysis using electro-spray positive-ion mode ionization (ESI(+)). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The MS/MS detection was conducted by monitoring the fragmentation of 821.7-->768.9 (m/z) for FK506, 415.5-->310.3 (m/z) for DTZ and 809.8-->757.0 (m/z) for IS. The method had a chromatographic running time of approximately 2 min and linear calibration curves over the concentrations of 0.5-200 ng/mL for FK506 and 2-250 ng/mL for DTZ. The recoveries of liquid-liquid extraction method were 58.3-62.6% for FK506 and 50.4-58.8% for DTZ. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for FK506 and 2 ng/mL for DTZ. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL for FK506 and 5, 25, and 100 ng/mL for DTZ. The validated LC/MS/MS method has been successfully used to analyze the concentrations of FK506 and DTZ in whole blood samples from pharmacokinetic studies in renal transplanted patients.  相似文献   

14.
A rapid equilibrium dialysis (RED) assay followed by a solid phase extraction (SPE) high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for the quantitative determination of unbound vismodegib in human plasma was developed and validated. The equilibrium dialysis was carried out using 0.3 mL plasma samples in the single-use plate RED system at 37°C for 6h. The dialysis samples (0.1 mL) were extracted using a Strata-X-C 33u Polymeric Strong Cation SPE plate and the resulting extracts were analyzed using reverse-phase chromatography and positive electrospray ionization (ESI) mass spectrometry. The standard curve, which ranged from 0.100 to 100 ng/mL for vismodegib, was fitted to a 1/x(2) weighted linear regression model. The lower limit of quantitation (LLOQ, 0.100 ng/mL) was sufficient to quantify unbound concentrations of vismodegib after dialysis. The intra-assay precision of the LC-MS/MS assay, based on the four analytical QC levels (LLOQ, low, medium and high), was within 7.7% CV and inter-assay precision was within 5.5% CV. The assay accuracy, expressed as %Bias, was within ±4.0% of the nominal concentration values. Extraction recovery of vismodegib was between 77.9 and 84.0%. The assay provides a means for accurate assessment of unbound vismodegib plasma concentrations in clinical studies.  相似文献   

15.
We have developed a sensitive, high-pressure liquid chromatographic-tandem mass spectrometric (LC/MS/MS) method for the simultaneous determination of didanosine (ddI) and stavudine (d4T) in human plasma, bronchoalveolar lavage fluid (BALF), alveolar cells (AC), peripheral blood mononuclear cells (PBMC), seminal plasma, cerebrospinal fluid (CSF), and tonsil tissue. Plasma, AC, PBMC and CSF were run with an isocratic HPLC method, while BALF supernatant, semen, and tonsil tissue utilized a gradient elution. Samples were prepared by solid phase extraction. Detection was by electrospray positive ionization with multiple reaction monitoring mode. The lower limits of quantitation for both ddI and d4T were 2.0 ng/ml in plasma; 0.5 ng/ml in CSF; 0.4 ng/ml in AC, PBMC, and BALF; 1.0 ng/ml in seminal plasma; and 0.01 ng/mg in tonsil tissue.  相似文献   

16.
A sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC/ESI/MS/MS) for the enantioselective determination of (S)-(+)-BMS-204352, a potent and specific maxi-K channel opener, in human, rat and dog plasma was developed. (S)-(+)-BMS-204352, its enantiomer (R)-(--)-BMS-204353 and the internal standard (13C-deuterated racemate of (S)-(+)-BMS-204352) were extracted from plasma using toluene. Chromatographic separation for the enantiomers was achieved on a Chiralcel OD-H analytical column with a run time of 8 min. An aqueous mobile phase modifier was added post column to enhance the mass spectrometer sensitivity. ESI mass spectra were acquired in the negative mode with selected reaction monitoring. The limit of quantitation (LLOQ) is 0.10 ng/mL for human plasma assay. Samples from a clinical study and two animal studies were processed using these procedures. Based on the in vivo data, lack of inversion of (S)-(+)-BMS-204352 to (R)-(--)-BMS-204353 was demonstrated in human, rat and dog after administration of the drug. A sensitive non-enantioselective LC/ESI/MS/MS assay has also been developed for (S)-(+)-BMS-204352 which uses a similar extraction procedure with a C18 column with a limit of quantitation at 0.05 ng/mL. Human study samples were analyzed by both methods and the correlation coefficient between both sets of data is greater than 0.99.  相似文献   

17.
LC/MS assays were developed to determine the plasma and intracellular concentrations of two aryl phosphoramidate prodrugs of the nucleotide analog 9-[2-R-(phosphonomethoxy)propyl]adenine. LC/MS was used to demonstrate the presence of high concentrations of PMPA in peripheral blood mononucleocytes following oral administration of prodrugs in dogs. High concentrations of PMPA and active metabolite were detected in MT-2 cells incubated with prodrug using an ion-pairing LC/MS assay.  相似文献   

18.
LC/MS assays were developed to determine the plasma and intracellular concentrations of two aryl phosphoramidate prodrugs of the nucleotide analog 9-[2-R-(phosphonomethoxy)propyl]adenine. LC/MS was used to demonstrate the presence of high concentrations of PMPA in peripheral blood mononucleocytes following oral administration of prodrugs in dogs. High concentrations of PMPA and active metabolite were detected in MT-2 cells incubated with prodrug using an ion-pairing LC/MS assay.  相似文献   

19.
High throughput LC-MS/MS assays to quantitate a new alpha(nu)beta(3) bone integrin antagonist (I) in human plasma and urine have been developed using instruments programmed to automate sample preparation procedures. Packard liquid handling system-MultiPROBE II EX was programmed for preparing calibration standards in control plasma and urine, acidifying all standards, quality control (QC), and clinical samples with necessary dilutions, and adding the internal standard to the acidified samples. TOMTEC Quadra 96 was programmed to perform the solid phase extraction (SPE) process on a 3M 96-well mixed phase cation standard density (MPC-SD) plate to isolate the analytes from the sample matrix. The extract collected from both types of matrices was directly injected into reversed-phase LC-MS/MS system with a Turbo Ion Spray (TIS) interface in the positive ionization mode. The plasma and urine assays have the calibration range of 0.5-1500 and 2-6000 ng/mL, respectively. Validation of the automated and the manual plasma assays showed that application of MultiPROBE II to sample preparation gave comparable accuracy and precision. Overall, the automated approaches with minimum manual intervention enhanced the throughput of sample preparation.  相似文献   

20.
An LC–MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3′,5′-monophosphate (cGMP) in human plasma. The LC–MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC–MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, 13C10,15N5-cGMP, which was biosynthesized in-house, was used in the LC–MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6–10.1% CV and ?3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6–8.1% CV and ?2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9–27.1% CV and ?4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1–39.5% CV and ?30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R2 = 0.197, P = 0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5–20 ng/mL. The LC–MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号