共查询到20条相似文献,搜索用时 10 毫秒
1.
Nuran Ercal Serdar Oztezcan Terese C. Hammond Richard H. Matthews Douglas R. Spitz 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,685(2):770
N-Acetylcysteine is a thiol antioxidant with expanding clinical importance. A sensitive, rapid method for determining reduced N-acetylcysteine (NAC) concentration in biological samples has been developed which uses a modified reversed-phase high-performance liquid chromatography (HPLC) technique in conjunction with the derivatizing agent N-(1-pyrenyl)maleimide (NPM). The NAC-NPM adduct was analyzed by HPLC with fluorescence detection. The calibration curve for NAC was linear over the range 8–2500 nM and the coefficient of variation obtained for the within-run precision and the between-run precision for 0.5 mM NAC was 1.5% and 2.7%, respectively. Relative recovery of NAC from biological materials ranged between 86% and 96% and the limit of quantitation from biological samples was 32 nM. These results suggest practical advantages relative to other widely-accepted methods of NAC measurement. 相似文献
2.
Angela Avenoso Gabriella Facciolà Giuseppe Maurizio Campo Antonio Fazio Edoardo Spina 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,714(2):737
An isocratic high-performance liquid chromatography (HPLC) method with ultraviolet detection for the simultaneous determination of clozapine and its two major metabolites in human plasma is described. Analytes are concentrated from alkaline plasma by liquid–liquid extraction with n-hexane–isoamyl alcohol (75:25, v/v). The organic phase is back-extracted with 150 μl of 0.1 M dibasic phosphate (pH 2.2 with 25% H3PO4). Triprolidine is used as internal standard. For the chromatographic separation the mobile phase consisted of acetonitrile–0.06 M phosphate buffer, pH 2.7 with 25% phosphoric acid (48:52, v/v). Analytes are eluted at a flow-rate of 1.0 ml/min, separated on a 250×4.60 mm I.D. analytical column packed with 5 μm C6 silica particles, and measured by UV absorbance detection at 254 nm. The separation requires 7 min. Calibration curves for the three analytes are linear within the clinical concentration range. Mean recoveries were 92.7% for clozapine, 82.0% for desmethylclozapine and 70.4% for clozapine N-oxide. C.V. values for intra- and inter-day variabilities were ≤13.8% at concentrations between 50 and 1000 ng/ml. Accuracy, expressed as percentage error, ranged from −19.8 to 2.8%. The method was specific and sensitive with quantitation limits of 2 ng/ml for both clozapine and desmethylclozapine and 5 ng/ml for clozapine N-oxide. Among various psychotropic drugs and their metabolites, only 2-hydroxydesipramine caused significant interference. The method is applicable to pharmacokinetic studies and therapeutic drug monitoring. 相似文献
3.
Michael Brunnenberg Hiltrud Lindenblatt Euphrosyne Gouzoulis-Mayfrank Karl-Artur Kovar 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,719(1-2)
A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCl. The maximum plasma concentrations were 235–465 ng/ml (MDE), 67–673 ng/ml (HME) and 7–33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves. 相似文献
4.
Aqel W. Abu-Qare Mohamed B. Abou-Donia 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,749(2):21
A rapid and simple method was developed for the separation and quantification of the anti nerve agent drug pyridostignmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), its metabolites m-toluamide and m-toluic acid, the insecticide permethrin (3-(2,2-dichloro-ethenyl)-2,2-dimethylcyclopropanecarboxylic acid(3-phenoxyphenyl)methylester), and two of its metabolites m-phenoxybenzyl alcohol, and m-phenoxybenzoic acid in rat plasma and urine. The method is based on using C18 Sep-Pak® cartridges for solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 208 and 230 nm. The compounds were separated using gradient of 1 to 99% acetonitrile in water (pH 3.20) at a flow-rate ranging between 0.5 and 1.7 ml/min in a period of 17 min. The retention times ranged from 5.7 to 14.5 min. The limits of detection were ranged between 20 and 100 ng/ml, while limits of quantitation were 150–200 ng/ml. Average percentage recovery of five spiked plasma samples were 51.4±10.6, 71.1±11.0, 82.3±6.7, 60.4±11.8, 63.6±10.1, 69.3±8.5, 68.3±12.0, 82.6±8.1, and from urine 55.9±9.8, 60.3±7.4, 77.9±9.1, 61.7±13.5, 68.6±8.9, 62.0±9.5, 72.9±9.1, and 72.1±8.0, for pyridostigmine bromide, DEET, permethrin, N-methyl-3-hydroxypyridinium bromide, m-toluamide, m-toluic acid, m-phenoxybenzyl alcohol and m-phenoxybenzoic acid, respectively. The relationship between peak areas and concentration was linear over the range between 100 and 5000 ng/ml. This method was applied to analyze the above chemicals and metabolites following their administration in rats. 相似文献
5.
Zhimeng Zhu Gia Klironomos Andre Vachereau Len Neirinck David W. Goodman 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,724(2):640
The first method using high-performance liquid chromatography (HPLC) has been developed for the determination of trans-resveratrol in human plasma. The method involves a liquid–liquid extraction followed by reversed-phase HPLC with UV detection. The detection limit of trans-resveratrol in human plasma was 5.0 ng/ml. Standard curves are linear over the concentration range of 5.0–5000.0 ng/ml. Intra-assay variability ranged from 1.9 to 3.7% and inter-assay variability ranged from 2.5 to 4.0% at the concentration range of 15.0–4000.0 ng/ml. 相似文献
6.
Alexander Staab Steffen Scheithauer Hiltrud Fieger-Büschges Ernst Mutschler Henning Blume 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,751(2)
An isocratic reversed-phase high-performance liquid chromatographic method for the simultaneous determination of denaverine and its N-monodemethyl metabolite (MD 6) in human plasma is described. The assay involves the extraction with an n-heptane–2-propanol mixture (9:1, v/v) followed by back extraction into 12.5% (w/w) phosphoric acid. The analytes of interest and the internal standard were separated on a Superspher RP8 column using a mobile phase of acetonitrile–0.12 M NH4H2PO4–tetrahydrofuran (24:17.2:1, v/v), adjusted to pH 3 with 85% (w/w) phosphoric acid. Ultraviolet detection was used at an operational wavelength of 220 nm. The retention times of MD 6, denaverine and the internal standard were 5.1, 6.3 and 10.2 min, respectively. The assay was validated according to international requirements and was found to be specific, accurate and precise with a linear range of 2.5–150 ng/ml for denaverine and MD 6. Extraction recoveries for denaverine and MD 6 ranged from 44 to 49% and from 42 to 47%, respectively. The stability of denaverine and MD 6 in plasma was demonstrated after 24 h storage at room temperature, after three freeze–thaw cycles and after 7 months frozen storage below −20°C. The stability of processed samples in the autosampler at room temperature was confirmed after 24 h storage. The analytical method has been applied to analyses of plasma samples from a pharmacokinetic study in man. 相似文献
7.
Luigi Perbellini Luciano Maestri Nello Veronese Serena Romani Francesco Brugnone 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,759(2)
Human biotransformation of the industrial solvent N,N-dimethylformamide gives raise to N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC) which has the longest half-life (about 23 h) among urinary metabolites of N,N-dimethylformamide. It could be used for monitoring industrial exposure over several workdays, by measuring it in urine samples collected at the end of the working week. This is consistent with the suggestions of the American Conference of Governmental Industrial Hygienists, which established a limit of 40 mg/l for the year 2000. An easy, cheap and user-friendly method has been developed for determination of urinary AMCC. Unlike currently available methods, it requires neither a time-consuming preparation phase nor gas chromatographic analysis with a nitrogen-phosphorus or mass detector. The method uses high-performance liquid chromatography (HPLC), with an UV detector at 436 nm. A 10-μl volume of urine is added to a carbonate–hydrogen carbonate buffer and mixed with a dabsyl chloride solution in acetonitrile. The reaction between AMCC and the reagent is performed at 70°C for 10 min. The ‘dabsylated’ product is stable for at least 12 h. After brief centrifugation, the solution is ready for HPLC analysis using a C18 column (250×4.6 mm, 5 μm). The method is sensitive (detection limit 1.8 mg/l) and specific. It identified urinary AMCC in urine of 40 subjects not exposed to N,N-dimethylformamide with a median concentration of 3.9 mg/l. In urine samples from 20 workers exposed to N,N-dimethylformamide (5–40.8 mg/m3), AMCC concentrations ranged from 16 to 170 mg/l. Industrial toxicology laboratories with limited instrumentation will be able to use it in the biological monitoring of workers exposed to N,N-dimethylformamide. 相似文献
8.
Wun-Chang Ko Jen-Yen Yang Chi-Ming Chen 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,685(2):1975
An HPLC assay is described for the determination of Z-butylidenephthalide (Z-Bdph) in plasma. Plasma samples were cleaned up by extraction with 2% chloroform in n-hexane. Z-Bdph was separated on a normal-phase silica column with a mobile phase of chloroform-n-hexane (1:1). The limit of quantitation with UV detection at 254 nm for Z-Bdph in plasma was 0.01 μg/ml. The recovery of Z-Bdph by organic solvent extraction of plasma was 99.5%. The intra-day and inter-day coefficients of variation and relative errors for Z-Bdph determination in plasma were both less than 10%. The present method was applied to pharmacokinetic studies of Z-Bdph in plasma after intravenous administration to rabbits. 相似文献
9.
Summary Effect ofN-acetyl-l-cysteine (NAC) administration on cysteine and glutathione (GSH) contents in rat liver and kidney was studied using intact and diethyl maleate (DEM)-treated rats and perfused rat liver. Cysteine contents increased rapidly, reaching peak at 10 min after intraperitoneal NAC administration. In liver mitochondria it increased slowly, reaching peak at 60 min. GSH content did not change significantly in these tissues. However, in liver and kidney depleted of GSH with DEM, NAC administration restored GSH contents in 60 and 120 min, respectively. Perfusion with 10 mM NAC resulted in 76% increase in liver cysteine content, but not in GSH content. Liver perfusion of DEM-injected rats with 10 mM NAC restored GSH content by 15%. Present findings indicate that NAC is an effective precursor of cysteine in the intact liver and kidney and in the perfused rat liver, and that NAC stimulated GSH synthesis in GSH-depleted tissues. 相似文献
10.
Eun-Hee Joo Woo-Ik Chang Injoon Oh Sang-Chul Shin Han-Kwang Na Yong-Bok Lee 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,723(1-2)
A rapid, selective and very sensitive ion-pairing reversed-phase HPLC method was developed for the simultaneous determination of trimebutine (TMB) and its major metabolite, N-monodesmethyltrimebutine (NDTMB), in rat and human plasma. Heptanesulfonate was employed as the ion-pairing agent and verapamil was used as the internal standard. The method involved the extraction with a n-hexane–isopropylalcohol (IPA) mixture (99:1, v/v) followed by back-extraction into 0.1 M hydrochloric acid and evaporation to dryness. HPLC analysis was carried out using a 4-μm particle size, C18-bonded silica column and water–sodium acetate–heptanesulfonate–acetonitrile as the mobile phase and UV detection at 267 nm. The chromatograms showed good resolution and sensitivity and no interference of plasma. The mean recoveries for human plasma were 95.4±3.1% for TMB and 89.4±4.1% for NDTMB. The detection limits of TMB and its metabolite, NDTMB, in human plasma were 1 and 5 ng/ml, respectively. The calibration curves were linear over the concentration range 10–5000 ng/ml for TMB and 25–25000 ng/ml for NDTMB with correlation coefficients greater than 0.999 and with within-day or between-day coefficients of variation not exceeding 9.4%. This assay procedure was applied to the study of metabolite pharmacokinetics of TMB in rat and the human. 相似文献
11.
Ben-Mei Chen Ling-Wei Xia Rui-Qin Zhao 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,692(2):1041
NG,NG-Dimethylarginine (asymmetric dimethylarginine, ADMA) can be directly separated and measured from deproteinized human plasma using o-phthaldialdehyde-mercaptoethanol (OPA reagent) as a fluorogenic reagent by reversed-phase high-performance liquid chromatography. The mean recovery of ADMA was over 96% and the inter- and intra-assay coefficients of variation of amounts were lower than 3.80% and those of retention time were below 0.37% for five runs. The detection limit of the assay is 1 pmol when the signal-to-noise is 3:1. It was observed that the concentration of ADMA was significantly elevated in plasma of patients with pregnancy induced hypertension (PIH) in contrast to healthy pregnant women. 相似文献
12.
Aqel W. Abu-Qare Mohamed B. Abou-Donia 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,757(2):503
A method was developed for the separation and quantification of the insecticide chlorpyrifos (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphorothioate), its metabolites chlorpyrifos-oxon (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphate) and TCP (3,5,6-trichloro-2-pyridinol), the anti-nerve agent drug pyridostigmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide), its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), and its metabolites m-toluamide and m-toluic acid in rat plasma and urine. The method is based on using solid-phase extraction and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 210 and 280 nm. The compounds were separated using a gradient of 1–85% acetonitrile in water (pH 3.20) at a flow-rate ranging between 1 and 1.7 ml/min over a period of 15 min. The retention times ranged from 5.4 to 13.2 min. The limits of detection ranged between 20 and 150 ng/ml, while the limits of quantitation were between 150 and 200 ng/ml. Average percentage recovery of five spiked plasma samples was 80.2±7.9, 74.9±8.5, 81.7±6.9, 73.1±7.8, 74.3±8.3, 80.8±6.6, 81.6±7.3 and 81.4±6.5, and from urine 79.4±6.9, 77.8±8.4, 83.3±6.6, 72.8±9.0, 76.3±7.7, 83.4±7.9, 81.6±7.9 and 81.8±6.8 for chlorpyrifos, chlorpyrifos-oxon, TCP, pyridostigmine bromide, N-methyl-3-hydroxypyridinium bromide, DEET, m-toluamide and m-toluic acid, respectively. The relationship between peak areas and concentration was linear over a range between 200 and 2000 ng/ml. 相似文献
13.
S. Diamantopoulou K. D. Stagiannis K. Vasilopoulos P. Barlas T. Tsegenidis N. K. Karamanos 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,732(2):28
The objectives of this study were the quantification of the two major sialic acid (Sia) forms – N-acetylneuraminic (Neu5Ac) and N-glycolylneuraminic acids (Neu5Gc) – in serum before and after surgical treatment of early endometrial cancer and the relation of their levels with the progress of surgical therapy. The major Sia forms were liberated from sera glycoconjugates by mild acid hydrolysis, separated as per-O-benzoylated derivatives by a highly sensitive reversed-phase HPLC method and detected at 231 nm. Total Sia content in sera of healthy women was not related to age and body weight. Neu5Ac was identified as the major Sia in sera from both cancer patients, healthy individuals as well as in tissue specimens (≥94% of total Sia). In patients with endometrial cancer the total Sia level before surgical treatment (709.5±306.5 mg/l) was significantly higher (p≤0.0001) than that of the control group (213.5±88.7 mg/l). The elevation in Sia level was exclusively due to Neu5Ac. Following surgical therapy, serum Neu5Ac levels (699.4±305.6 mg/l) were significantly decreased (305.9±114.5 mg/l). In one case, where Neu5Ac level was increased 15 days and eight months after surgery (1.8 and 2.5 times as compared to control, respectively), a metastasis not detected during surgery was recorded. The obtained results suggest that Neu5Ac level in serum may be used as a tumor marker in evaluating the suitability of surgical treatment in early endometrial cancer. 相似文献
14.
Lina Long Douglas R. McCabe M. Eileen Dolan 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,731(2):128
A highly sensitive and selective method for determining 8-oxoguanine in plasma and urine was developed by high-performance liquid chromatography with electrochemical detection. The compound was separated by gradient elution on a C18 reversed-phase column with a mobile phase of acetonitrile and 0.1 M sodium acetate, pH 5.2. 8-Hydroxy-2′-deoxyguanosine was used as internal standard. 8-Oxoguanine was detected electrochemically by setting the potential to +300 mV vs. Pd reference. The sensitivity of the assay was 22 ng/ml with a signal-to-noise ratio of 7:1. The within-day relative standard deviations for 8-oxoguanine quality control samples with concentrations of 3340, 1340 and 84 ng/ml were 3.6, 4.3 and 5.7% for plasma, and 4.1, 4.6 and 6.2% for urine, respectively. The day-to-day relative standard deviations for the same samples were 3.8, 6.8 and 7.1% for plasma, and 3.9, 7.0 and 7.9% for urine, respectively. The method is designed to study the pharmacokinetics and metabolic fate of O6-benzylguanine in a phase I clinical trial. Previously, O6-benzyl-8-oxoguanine was identified as the primary metabolite of O6-benzylguanine in humans. We now demonstrate that 8-oxoguanine is a further metabolite of O6-benzylguanine. 相似文献
15.
Harald Hoja Pierre Marquet Bernard Verneuil Hayat Lotfi Jean-Louis Dupuy Gérard Lachâtre 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,692(2):3301
A sensitive and highly specific method for the determination of LSD and N-demethyl-LSD in urine, using combined liquid chromatography and mass spectrometry (LC-MS) with electrospray ionization, has been developed. Extrelut-3 extraction cartridges were used for a basic sample clean-up. Elution was obtained by toluene-diethyl ether (60:40, v/v). A Nucleosil C18 (150×1 mm I.D.) reversed-phase column was used for the chromatographic separation, together with a mixture of 2 mM ammonium formate buffer (pH 3) and acetonitrile (70:30, v/v) as mobile phase. Recoveries were 93 and 80%, detection limits 0.025 and 0.035 ng/ml for LSD and N-demethyl-LSD, respectively. Intra-assay precision, studied at four concentrations, was better than 9% at the ng/ml range and better than 14% at 0.10 ng/ml for both compounds. Limits of quantitation were 0.05 and 0.10 ng/ml for LSD and N-demethyl-LSD, respectively. Reproducibility was good and linearity excellent for LSD in the range from 0.05 to 20 ng/ml (r>0.9999, N=7). 相似文献
16.
Huaibing He Abu Sadeque John C. L. Erve Alastair J. J. Wood David L. Hachey 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,744(2):137
We report here the development and validation of an LC–MS method for quantitation of loperamide (LOP) and its N-demethyl metabolite (DMLOP) in human plasma. O-Acetyl-loperamide (A-LOP) was synthesized by us for use as an internal standard in the assay. After addition of the internal standard, the compounds of interest were extracted with methyl tert.-butylether and separated by HPLC on a C18 reversed-phase column using an acetonitrile–water gradient containing 20 mM ammonium acetate. The three compounds were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in plasma. Analytes were quantitated using positive electrospray ionization in a triple quadrupole mass spectrometer operating in the MS–MS mode. Selected reaction monitoring was used to quantify LOP (m/z 477→266), DMLOP (m/z 463→252) and A-LOP (m/z 519→266) on ions formed by loss of the 4-(p-chlorophenyl)-4-hydroxy-piperidyl group upon low energy collision-induced dissociation. Calibration curves, which were linear over the range 1.04 to 41.7 pmol/ml (LOP) and 1.55 to 41.9 pmol/ml (DMLOP), were run contemporaneously with each batch of samples, along with low (4.2 pmol/ml), medium (16.7 pmol/ml) and high (33.4 pmol/ml) quality control samples. The lower limit of quantitation (LLQ) of LOP and DMLOP was about 0.25 pmol/ml in plasma. The extraction efficiency of LOP and DMLOP from human plasma was 72.3±1.50% (range: 70.7–73.7%) and 79.4±12.8% (64.9–88.8%), respectively. The intra- and inter-assay variability of LOP and DMLOP ranged from 2.1 to 14.5% for the low, medium and high quality control samples. The method has been used successfully to study loperamide pharmacokinetics in adult humans. 相似文献
17.
Gabriela Cimpan Florin Irimie Simion Gocan Henk A. Claessens 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,714(2):4246
The partition coefficients, P, between n-octanol and water of a number of growth stimulating substances, N-hydroxyethylamide of aryloxyalkylen- and pyridine carboxylic acids were obtained from Pomona College (C log P), and Rekker's (log PRekker) revised fragmental constant system was used to calculate log P data sets. Both of these data sets were correlated with two different substance lipophilicity parameters, log kw and 0. Log kw was obtained by extrapolation of log retention factor (k) to 0% organic modifier measured in reversed-phase liquid chromatography (RPLC) systems. 0 values were obtained from the slopes and intercepts of these relationships. The RPLC experiments were performed on four commercially available reversed-phase columns. Binary mixtures of methanol–water, methanol–phosphate buffer (pH 7.0), methanol–tricine buffer (pH 7.0) and acetonitrile–water were used as mobile phases for the determination of log kw values. For the methanolic eluents linear regression provided satisfactory correlations (r>0.99) for the relationships log k vs. organic modifier content in the eluent, while for the acetonitrile-containing eluents a second-degree polynominal regression was necessary. For all four RPLC columns, by linear regression satisfactory correlations (r>0.99) were obtained between log kw and log P data using methanolic eluents. In such eluents 0 values were shown to be the second-best lipophilicity parameters. For acetonitrile-containing eluents the use of second-degree polynominal regression was necessary and, in contrast to methanol, significant influence of the applied column on regression results was observed. For acetonitrile-containing eluents the 0-index does not provide satisfactory results for our substances. No difference in regression results between the use of buffered and non-buffered eluents was observed. 相似文献
18.
Renato Bortocan Vera Lúcia Lanchote Evandro Jos Cesarino Pierina Sueli Bonato 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,744(2)
An enantioselective high-performance liquid chromatography method was developed for the simultaneous determination of disopyramide (DP) and mono-N-dealkyldisopyramide (MND) enantiomers in plasma and urine. The drugs were extracted from plasma samples by liquid–liquid extraction with dichloromethane after protein precipitation with trichloroacetic acid; the urine samples were processed by liquid–liquid extraction with dichloromethane. The enantiomers were resolved on a Chiralpak AD column using hexane–ethanol (91:9, v/v) plus 0.1% diethylamine as the mobile phase and monitored at 270 nm. Under these conditions the enantiomeric fractions of the drug and of its metabolite were analyzed within 20 min. The extraction procedure was efficient in removing endogenous interferents and low values for the relative standard deviations were demonstrated for both within-day and between-day assays. The method described in this paper allows the determination of DP and MND enantiomers at plasma levels as low as 12.5 ng/ml and can be used in clinical pharmacokinetic studies. 相似文献
19.
P. Campíns-Falc C. Molins-Legua A. Sevillano-Cabeza L. A. Tortajada Genaro 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,759(2):1162
A comparative study of different derivatization procedures has been performed in order to improve the stability of the reaction products o-phthalaldehyde–N-acetylcysteine (OPA–NAC) polyamines. Procedures such as solution derivatization, solution derivatization followed by retention on a packing support, derivatization on different packing supports and on-column derivatization, have been optimized and compared. The degradation rate constant (k) of the derivative was dependent on the procedure used and on the analyte. For the spermine (the most unstable isoindol tested) k was 8±2×10−2 min−1 in solution versus 7.7±1.1×10−4 min−1 on the (C18) solid support. The results obtained showed that forming the derivative on the packing support (C18) gave the best results following this procedure: conditioning the cartridges with borate buffer (1 ml, 0.5 M, pH 8), retention of the analyte, addition of 0.8 ml of OPA–NAC reagent, 0.2 ml borate buffer 0.8 M (pH 8) and elution of the isoindol with 3 ml of MeOH–borate buffer (9:1). The different derivatization procedures have been used to study the stability of the reaction products OPA–NAC polyamines formed in urine matrix using spermine as model compound. Similar results were obtained for standard solutions and urine samples. 相似文献
20.
Tammy L. Stefan Stephen T. Ingalls Stanton L. Gerson James K.V. Willson Charles L. Hoppel 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,681(2):331
A high-performance liquid chromatographic assay for O6-benzylguanine utilizing liquid-liquid extraction and reversed-phase chromatography has been developed. Plasma samples were alkalinized, extracted into ethyl acetate, evaporated, and the residues were constituted and chromatographed. Separation was accomplished by gradient elution with a mobile phase of methanol, acetonitrile, and phosphate buffer, pH 3.2. Eluted compounds were detected spectrophotometrically at 280 nm. Sample quantitation was obtained from the regression line of six-point standard curves ranging from 25 to 400 ng/ml. O6-Benzylguanine peak heights were compared to peak heights of O6-(p-chlorobenzyl)guanine (internal standard). The average regression coefficient was 0.999 (n = 4). High concentration (305 ng/ml) and low concentration (38 ng/ml) quality control samples were determined with a day-to-day relative standard deviation of 7 and 8%, respectively (n = 18). The within-day relative standard deviations were 2.7 and 3.0% (n = 18) for the high and low concentration quality control specimens, respectively. Sample quantitation was reliable to 25 ng/ml with a signal-to-noise ratio of 8:1. This method was applied to plasma samples obtained from patients in a clinical trial of O6-benzylguanine. 相似文献