首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A fluorescence technology to monitor the proliferation of amyloidogenic neurological disorders is proposed. A crude brain homogenate (0.01%) from animals infected with a transmissible spongiform encephalopathy is employed as a catalytic medium initiating conformational changes in 520 nM polypeptide biosensors (Tris/trifluoroethanol 50% mixture at pH 7). The fluorescence methods utilize pyrene residues covalently attached to the peptide ends. The coil-to-β-strand transitions in biosensor molecules cause elevation of a distinct fluorescence band of the pyrene aggregates (i.e. excimers). This approach enables the detection of infectious prion proteins at fmol, does not require antibody binding or protease treatment. Technology might be adopted for diagnosing a large variety of conformational disorders as well as for generic high-throughput screening of the amyloidogenic potential in plasma.  相似文献   

2.
Photonic induced immobilization is a novel technology that results in spatially oriented and spatially localized covalent coupling of biomolecules onto thiol-reactive surfaces. Immobilization using this technology has been achieved for a wide selection of proteins, such as hydrolytic enzymes (lipases/esterases, lysozyme), proteases (human plasminogen), alkaline phosphatase, immunoglobulins' Fab fragment (e.g., antibody against PSA [prostate specific antigen]), Major Histocompability Complex class I protein, pepsin, and trypsin. The reaction mechanism behind the reported new technology involves "photonic activation of disulfide bridges," i.e., light-induced breakage of disulfide bridges in proteins upon UV illumination of nearby aromatic amino acids, resulting in the formation of free, reactive thiol groups that will form covalent bonds with thiol-reactive surfaces (see Fig. 1). Interestingly, the spatial proximity of aromatic residues and disulfide bridges in proteins has been preserved throughout molecular evolution. The new photonic-induced method for immobilization of proteins preserves the native structural and functional properties of the immobilized protein, avoiding the use of one or more chemical/thermal steps. This technology allows for the creation of spatially oriented as well as spatially defined multiprotein/DNA high-density sensor arrays with spot size of 1 microm or less, and has clear potential for biomedical, bioelectronic, nanotechnology, and therapeutic applications.  相似文献   

3.
A reagentless enzymatic optical biosensor has been constructed to measure the concentration of ethylene dibromide (EDB, 1,2‐dibromoethane), a US EPA Priority Pollutant. This biosensor is based on the haloalkane dehalogenase DhaA, which generates protons as a product of the dehalogenation of EDB. The resulting pH change is detected as a shift in the fluorescence intensity of fluoresceinamine. When layers of fluoresceinamine and Rhodococcus sp. GJ70 expressing DhaA were immobilized on the tip of an optical fiber, the resulting changes in fluorescence were proportional to the EDB concentration in the range 1–10 μg/L and nonlinear (saturation‐type trend) for concentrations up to 10 mg/L. EDB concentrations as low as 1 μg/L could be detected in aqueous solutions. Both the pH and buffer capacity of the sample had significant effects on the sensor's performance. EDB biosensors were active for at least 37 d, although their sensitivity decreased after 7 d. The biosensor's potential to measure continuously and in situ could make it useful for environmental or water treatment process monitoring systems.  相似文献   

4.
光纤倏逝波生物传感器及其应用   总被引:2,自引:0,他引:2  
介绍光纤倏逝波生物传感器的基本原理、常用试验方法、基本仪器构建及应用进展。光纤倏逝波生物传感器是基于光波在光纤内以全反射方式传输时产生倏逝波的原理,以生物分子作为敏感元件进行检测的一类新兴传感器。光纤倏逝波生物传感器有望应用于环境监控、食品卫生监控、临床疾病监测、DNA检测和生物战剂检测。  相似文献   

5.
The development of portable systems for analysis of nucleic acids (NAs) is crucial for the evolution of biosensing in the context of future healthcare technologies. The integration of NA extraction, purification, and detection modules, properly actuated by microfluidics technologies, is a key point for the development of portable diagnostic systems. In this paper, we describe an integrated biosensor platform based on a silicon–plastic hybrid lab-on-disk technology capable of managing NA extraction, purification, and detection processes in an integrated format. The sample preparation process is performed by solid-phase extraction technology using magnetic beads on a plastic disk, while detection is done through quantitative real-time polymerase chain reaction (qRT-PCR) on a miniaturized silicon device. The movement of sample and reagents is actuated by a centrifugal force induced by a disk actuator instrument. The assessment of the NA extraction and detection performance has been carried out by using hepatitis B virus (HBV) DNA genome as a biological target. The quantification of the qRT-PCR chip in the hybrid disk showed an improvement in sensitivity with respect to the qRT-PCR commercial platforms, which means an optimization of time and cost. Limit of detection and limit of quantification values of about 8 cps/reaction and 26 cps/reaction, respectively, were found by using analytical samples (synthetic clone), while the results with real samples (serum with spiked HBV genome) indicate that the system performs as well as the standard methods.  相似文献   

6.
A new strategy for the construction of a polyphenol oxidase carbon paste biosensor for paracetamol detection is reported. The eggplant (Solanum melongena) was processed to collect the polyphenol oxidase as an enzyme that was incorporated in the carbon paste sensor construction. The constructed sensor displayed high sensitivity and good selection for paracetamol detection and recognition. Optimized conditions included pH 6.0 (highest activity), pH 7.0 (highest stability), pulse amplitude of 50?mV, and 15% of vegetable extract per carbon paste. The sensor displayed a linear range from 20 to 200?µM, with a detection limit of 5?µM. Application of the sensor to paracetamol determination in tablet and oral solutions have shown satisfactory results. The efficiency of the method showed very good repeatability ranging between 1.26 and 1.72% relative standard deviation for interday analysis, while recoveries for paracetamol varied between 97.5 and 99.8% for the voltammetric determination. The strategy for a simple, low cost, and efficient eggplant polyphenol oxidase sensor showcased in this work provides an opportunity for the detection of other phenolic compounds in various matrices.  相似文献   

7.
Three ferrocenes used in glucose biosensor construction were tested in the aspect of genotoxic and immunotoxic activities. All three ferrocenes were not mutagenic in the standard bacterial Ames test. Equally in the Sister Chromatid Exchanges test in human lymphocyte cultures, the genotoxic action of tested ferrocenes could be excluded. However, all three significantly decreased the rate of lymphocyte proliferation and especially diminished the numbers of B-lymphocytes and NK-cells after 72 hours of in vitro culture. Marked differences between the ferrocenes in their immunotoxic activities were noticed, and we were able to select those which would be relatively safe and those which should be avoided in further investigation of the glucose biosensor construction. Our results indicate the necessity to estimate immunotoxic effects as well as genotoxic effects, especially in biosensor components potentially used in vivo  相似文献   

8.
DNA生物传感器及其研究进展   总被引:10,自引:0,他引:10  
就DNA生物传感器的工作原理,分类、DNA探针的固化方法,以及电化学DNA生物传感器、光学DNA生物传感器及压电DNA生物传感器的研究进展、优缺点和发展趋势加以介绍。  相似文献   

9.
A live cell array biosensor was fabricated by immobilizing bacterial cells on the face of an optical imaging fiber containing a high-density array of microwells. Each microwell accommodates a single bacterium that was genetically engineered to respond to a specific analyte. A genetically modified Escherichia coli strain, containing the lacZ reporter gene fused to the heavy metal-responsive gene promoter zntA, was used to fabricate a mercury biosensor. A plasmid carrying the gene coding for the enhanced cyan fluorescent protein (ECFP) was also introduced into this sensing strain to identify the cell locations in the array. Single cell lacZ expression was measured when the array was exposed to mercury and a response to 100nM Hg(2+) could be detected after a 1-h incubation time. The optical imaging fiber-based single bacterial cell array is a flexible and sensitive biosensor platform that can be used to monitor the expression of different reporter genes and accommodate a variety of sensing strains.  相似文献   

10.
11.
Olfactory receptors, which are responsible for sensing odor molecules, form the largest G protein-coupled receptor (GPCR) family in mammalian animals. These proteins play an important role in the detection of chemical signals and signal transduction to the brain. Currently, only a limited number of olfactory receptors have been characterized, which is mainly due to the lack of sensitive and efficient tools for performing functional assays of these receptors. This paper describes a novel surface acoustic wave (SAW)-based biosensor for highly sensitive functional assays of olfactory receptors. An olfactory receptor of Caenorhabditis elegans, ODR-10, was expressed on the plasma membrane of human breast cancer MCF-7 cells, which was used as a model system for this study. For specific odorant response assays, the membrane fraction of MCF-7 cells containing ODR-10 was extracted and integrated with our SAW sensors. The response of ODR-10 to various odorants was monitored by recording the resonance frequency shifts of SAWs applied to the sensor. Our results show that heterologously expressed ODR-10 receptors can specifically respond to diacetyl, its natural ligand. Dose-dependent responses were obtained by performing measurements using various concentrations of diacetyl. The sensitivity of this biosensor is 2 kHz/ng and can detect concentrations as low as 10−10 mM, which is 10× lower than what has previously been reported. This biosensor can be used to characterize odorant response profiles of olfactory receptors and provide information rich data for functional assays of olfactory receptors. In addition to providing a greater understanding of the biological mechanisms of GPCRs, such data holds great potential in many other fields such as food industry, biomedicine, and environmental protection.  相似文献   

12.
This paper describes the preparation of an organic charge transfer complex (CTC) based printable enzyme electrode. CTC crystals were prepared by mixing TCNQ powder with TTF solution (in acetonitrile). Glucose oxidase (GOD) was adsorbed at the CTC crystal surface in a monolayer. A printable paste was prepared by mixing GOD-adsorbed crystals with a binder and a solvent. This paste was applied to an electrode cavity and vacuum dried. A thin layer of gelatin was cast on the paste filled dried electrode, and cross-linked with glutaraldehyde in the dry condition. The sensors were fixed in a flow injection system, and continuously polarized at 0·15 V and 37°C, and the samples were automatically injected every 30 min. The developed sensors produced a huge response curren with an extended linear range of detection (0–100 mM) and the response was unaffected by the presence of normal oxygen in the buffer solution. The sensor showed excellent stability. The performance of the sensors was significantly influenced by the binder used.  相似文献   

13.
To distinguish the mass loading effect from the total frequency change is a problem in the application of a quartz crystal microbalance (QCM) biosensor in the liquid phase. Based on the characteristic damping theory, this paper proposes a new method of dual modulation to solve this problem. Usingg polyethyleneimine to immobilize anti-SE (staphylococcin enterotoxin) antibody (C2 type), a dual modulated QCM SE biosensor was developed and the experiment proved that it has little cross-reaction with B-type SE. The measuring curve of the sensor was also determined through experiment.  相似文献   

14.
利用厚叶景天的叶和茎组织作为生物催化材料,分别同二氧化碳气敏电极和氨气敏电极组合,研制了L-精氨酸传感器及,L-赖氨酸传感器。两种传感器的线性范围分别为1.0×10-4 1.O×10-3mol/L和8.0×10-5—3.0×10-3mol/L.检测下限分别为3.2×10-5mol/L和2.2×10-5mol/L,响应斜率分别为42.2mV/dec和41.4mv/dec。考察了两种传感器的回收率.结果表明,L-精氨酸传感器和L-赖氨酸传感器的回收率平均值分别为98.6%和101.6%,标准偏差分别为4.6%和4.0%。  相似文献   

15.
Measurements of pollutants such as toluene are critical for the characterization of contaminated sites and for the monitoring of remediation processes and wastewater treatment effluents. Fiber optic enzymatic biosensors have the potential to provide cost-effective, real time, continuous, in situ measurements. In this study, a fiber optic enzymatic biosensor was constructed and characterized for the measurement of toluene concentrations in aqueous solutions. The biological recognition element was toluene ortho-monooxygenase (TOM), expressed by Escherichia coli TG1 carrying pBS(Kan)TOM, while an optical fiber coated with an oxygen-sensitive ruthenium-based phosphorescent dye served as the transducer. Toluene was detected based on the enzymatic reaction catalyzed by TOM, which resulted in the consumption of oxygen and changes in the phosphorescence intensity. The biosensor was found to have a limit of detection of 3 μM, a linear signal range up to 100 μM, and a response time of 1 h. The performance was reproducible with different biosensors (RSD=7.4%, n=8). The biosensor activity declined with each measurement and with storage time, particularly at elevated temperatures. This activity loss could be partially reversed by exposure to formate, suggesting that NADH consumption was the primary factor limiting lifetime. This is the first report of an enzymatic toluene sensor and of an oxygenase-based biosensor. Since many oxygenases have been reported, the design concept of this oxygenase-based biosensor has the potential to broaden biosensor applications in environmental monitoring.  相似文献   

16.
This paper demonstrates that glucose determination in blood can be done directly (without sample pretreatment) using a reagentless reversible biosensor based on the intrinsic spectroscopic properties of peroxidase (HRP). The biosensor, prepared by HRP and glucose oxidase entrapment in a polyacrylamide gel matrix, works in continuous mode, presents a linear response range from 1.5 × 10−6 up to 5.5 × 10−5 M and can be used for at least 750 measurements; in the best conditions (0.1 M pH 6 phosphate buffer, HRP and GOx amounts in the polymersation mixture for the sensor film preparation 0.0165 and 0.0010 g, respectively) the minimum samples rate is 30 h−1. For glucose determination, blood is simply diluted in water (until haemolysis is completed) and fed into the sensor without a cleaning step between samples; the blood absorption is corrected in a simple way by working at a proper reference wavelength. The biosensor signals have been mathematically modeled in order to facilitate the design of sensors based on the same idea for other biochemical compounds.  相似文献   

17.
马钊  李猛 《生物工程学报》2023,39(7):2706-2718
土壤中污染物的生物有效性评估对于准确评价环境污染风险至关重要,而全细胞生物传感器是此类评估的重要工具之一。本研究旨在使用新型全细胞生物传感器建立土壤中甲基对硫磷(methyl parathion,MP)的检测方法。首先,使用筛选出的甲基对硫磷水解酶基因(methyl parathion degrading gene,mpd)和pUC19质粒骨架以及已有的特异性诱导元件pobR为材料,构建全细胞生物传感器。然后,以96孔的酶标板为载体和以5种全细胞生物传感器为指示细胞,建立了土壤提取液样品中甲基对硫磷的分析方法,并应用于实际测试和田间土壤样品中甲基对硫磷的检测。以检测性能的最佳大肠杆菌(Escherichia coli)DH5α/pMP-AmilCP为例,其检测限为6.21−6.66μg/L,线性范围为10−10000μg/L。E.coli DH5α/pMP-RFP和E.coli DH5α/pMP-AmilCP的方法用于分析土壤提取液样品中甲基对硫磷的浓度,具有较好的检测性能。这种全细胞生物传感器方法有助于快速评估土壤中甲基对硫磷的生物有效性强弱,从而有效判断有机磷农药甲基对硫磷对土壤的污染风险。  相似文献   

18.
We explore the dynamic properties of multiple-beam optical traps to manipulate arrays of microstructures for biosensor applications. Multiple optical traps are generated by a virtually loss-less transformation of input phase patterns into high-intensity trapping-beams. A direct image projection of the phase patterns enables an adjustable number of optical traps in addition to instantaneous control of the position, size, shape and intensity of each trapping-beam. We present experimental results showing various colloidal formations through dynamic optical manipulation of polystyrene microspheres and yeast cells in aqueous media. The experimental configurations are geared towards the use of multiple-beam optical traps for biosensor applications.  相似文献   

19.
A large-surface biosensor technique using surface plasmon resonance (SPR) was tested for protein purification by recovery of a monoclonal antibody against human proinsulin C-peptide. Notably, both reversible attachment/desorption and actual purification of the antibody from a multi-component protein mixture was shown. For initial chip attachment of the peptide ligand, C-peptide was biotinylated and attached to neutravidin on plastic chips with a large gold surface (effective area 26 mm(2)). Antibody binding and desorption was monitored in real-time SPR, and for elution different conditions were employed. Five percent formic acid (in contact with the chip surface for 3 min) in a 60-mul segment between air bubbles was efficient for subsequent analysis. In this manner, protein amounts up to 35 pmoles were recovered in a single capture/elution cycle. Evaluation by SDS-PAGE showed essentially no carryover between fractions in this elution process, and also not with other proteins in the mixture after purification. Compared to existing commercial instruments, this technique gives higher recovery and makes it possible to monitor monitor protein binding/desorption. Recovery of affinity partners at the multi-pmole level is demonstrated for protein purification in SPR approaches.  相似文献   

20.
Due to the increasing number of nosocomial infections and multidrug‐resistant bacterial strains, Staphylococcus aureus is now a major worldwide concern. Rapid detection and characterization of this bacterium has become an important issue for biomedical applications. Biosensors are increasingly appearing as low‐cost, easy‐to‐operate and fast alternatives for rapid detection. In this review, we will introduce the main characteristics of S. aureus and will focus on the interest of biosensors for a faster detection of whole S. aureus cells. In particular, we will review the most promising strategies in the choice of ligand for the design of selective and efficient biosensors. Their specific characteristics as well as their advantages and/or disadvantages will also be commented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号