Three dimensional finite element models of cam-type FAI with alpha angles of 60°, 70°, 80°, and 90° were created to investigate the cartilage contact mechanics in daily activities. Intra-articular cartilage contact pressures during routine daily activities were assessed and cross-compared with a normal control hip. Alpha angles and hip range of motion were found to have a combined influence on the cartilage contact mechanics in hips with cam-type FAI, thereby resulting in abnormally high pressures and driving the cartilage damage. In particular, alpha angles of 80° or greater contribute to substantial pressure increase under certain types of daily activities.  相似文献   

2.
3.
Transtibial amputation prosthetic-users are at risk of developing deep tissue injury (DTI) while donning their prosthesis for prolonged periods; however, no study addresses the mechanical loading of the residuum during sitting with a prosthesis. We combined MRI-based 3D finite element modelling of a residuum with an injury threshold and a muscle damage law to study risks for DTI in one sitting subject in two postures: 30°-knee-flexion vs. 90°-knee-flexion. We recorded skin-socket pressures, used as model boundary conditions. During the 90°-knee-flexion simulations, major internal muscle injuries were predicted (>1000 mm3). In contrast, the 30°-knee-flexion simulations only produced minor injury ( < 14 mm3). Predicted injury rates at 90°-knee-flexion were over one order of magnitude higher than those at 30°-knee-flexion. We concluded that in this particular subject, prolonged 90°-knee-flexion sitting theoretically endangers muscle viability in the residuum. By expanding the studies to large subject groups, this research approach can support development of guidelines for DTI prevention in prosthetic-users.  相似文献   

4.
Orthopedic insole was important for partial foot amputation (PFA) to achieve foot balance and avoid foot deformity. The inapposite insole orthosis was thought to be one of the risk factors of reamputation for foot valgus patient, but biomechanical effects of internal tissues on valgus foot had not been clearly addressed. In this study, plantar pressure on heel and metatarsal regions of PFA was measured using F-Scan. The three-dimensional finite element (FE) model of partial foot evaluated different medial wedge angles (MWAs) (0.0°–10.0°) of orthopedic insole on valgus foot. The effect of orthopedic insole on the internal bone stress, the medial ligament tension of ankle, plantar fascia tension, and plantar pressure was investigated. Plantar pressure on medial heel region was about 2.5 times higher than that of lateral region based on the F-Scan measurements. FE-predicted results showed that the tension of medial ankle ligaments was the lowest, and the plantar pressure was redistributed around the heel, the first metatarsal, and the lateral longitudinal arch regions when MWA of orthopedic insole ranged from 7.5° to 8.0°. The plantar fascias maintained about 3.5% of the total load bearing on foot. However, the internal stresses from foot bones increased. The simulation in this study would provide the suggestion of guiding optimal design of orthopedic insole and therapeutic planning to pedorthist.  相似文献   

5.
6.
A new strategy of multi-objective structural optimization is integrated into Austin-Moore prosthesis in order to improve its performance. The new resulting model is so-called Improved Austin-Moore. The topology optimization is considered as a conceptual design stage to sketch several kinds of hollow stems according to the daily loading cases. The shape optimization presents the detailed design stage considering several objectives. Here, A new multiplicative formulation is proposed as a performance scale in order to define the best compromise between several requirements. Numerical applications on 2D and 3D problems are carried out to show the advantages of the proposed model.  相似文献   

7.
In this study, a three-dimensional finite element (FE) model based on the specific anatomy of a patient presenting a femoroacetabular impingement of the ‘cam’-type is developed. The FE meshes of the structures of interest are obtained from arthrographic magnetic resonance images. All soft tissues are considered linear elastic and isotropic, and the bones were assumed rigid. A compression of the femur on the acetabular cavity as well as flexural movements and internal rotations are applied. Stresses and contact pressures are evaluated in this patient-specific model in order to better interpret the mechanism of aggression of the femoral and acetabular cartilages. The corresponding results are presented and discussed. The values obtained for the contact pressures are similar to those reported by other models based on idealised geometries. An FE analysis of a non-cam hip is also performed for comparison with the pathological case.  相似文献   

8.
The purpose of this study was to determine whether modifying an existing, highly biofidelic full body finite element model [total human model for safety (THUMS)] would produce valid amplitude and temporal shock wave characteristics as it travels proximally through the lower extremity. Modifying an existing model may be more feasible than developing a new model, in terms of cost, labour and expertise. The THUMS shoe was modified to more closely simulate the material properties of a heel pad. Relative errors in force and acceleration data from experimental human pendulum impacts and simulated THUMS impacts were 22% and 54%, respectively, across the time history studied. The THUMS peak acceleration was attenuated by 57.5% and took 19.7 ms to travel proximally along the lower extremity. Although refinements may be necessary to improve force and acceleration timing, the modified THUMS represented, to a certain extent, shock wave propagation and attenuation demonstrated by living humans under controlled impact conditions.  相似文献   

9.
10.
Currently, there are a number of nucleus replacements under development. The important concern is how well these implants duplicate the mechanical function of the native nucleus. This finite element model study aimed to investigate the influence of different nucleus replacements on the mechanical response of the disc. Models included partial, full, over-sized, partially saturated, elastic and poroelastic solid replacements. Over-sized nucleus replacements up to 25% yielded results that were comparable to those in the intact state. Differences were much greater in cases with under-sized nucleus replacements. The effect was most pronounced for the 75% under-sized replacement that resembled the condition with a full nucleotomy. Nucleus implants with elastic properties substantially altered load transmission when 10% under-sized and over-sized replacements were considered. Compared to intact, the under-sized implants should be avoided when using biphasic materials with properties similar to the native nucleus, whereas for elastic replacements both under- and over-sized implants should not be used.  相似文献   

11.
Modelling transversely isotropic materials in finite strain problems is a complex task in biomechanics, and is usually addressed by using finite element (FE) simulations. The standard method developed to account for the quasi-incompressible nature of soft tissues is to decompose the strain energy function (SEF) into volumetric and deviatoric parts. However, this decomposition is only valid for fully incompressible materials, and its use for slightly compressible materials yields an unphysical response during the simulation of hydrostatic tension/compression of a transversely isotropic material. This paper presents the FE implementation as subroutines of a new volumetric model solving this deficiency in two FE codes: Abaqus and FEBio. This model also has the specificity of restoring the compatibility with small strain theory. The stress and elasticity tensors are first derived for a general SEF. This is followed by a successful convergence check using a particular SEF and a suite of single-element tests showing that this new model does not only correct the hydrostatic deficiency but may also affect stresses during shear tests (Poynting effect) and lateral stretches during uniaxial tests (Poisson's effect). These FE subroutines have numerous applications including the modelling of tendons, ligaments, heart tissue, etc. The biomechanics community should be aware of specificities of the standard model, and the new model should be used when accurate FE results are desired in the case of compressible materials.  相似文献   

12.
A computational model for exploring the design of a voice-producing voice prosthesis, or voice-producing element (VPE), is presented. The VPE is intended for use by laryngectomized patients who cannot benefit from current speech rehabilitation techniques. Previous experiments have focused on the design of a double-membrane voice generator as a VPE. For optimization studies, a numerical model has been developed. The numerical model introduced incorporates the finite element (FE) method to solve for the flow-induced vibrations of the VPE system, including airflow coupled with a mass-loaded membrane. The FE model includes distinct but coupled fluid and solid domains. The flow solver is governed by the incompressible, laminar, unsteady Navier–Stokes equations. The solid solver allows for large deformation, large strain, and collision. It is first shown that the model satisfactorily represents previously published experimental results in terms of frequency and flow rate, enabling the model for use as a design tool. The model is then used to study the influence of geometric scaling, membrane thickness, membrane stiffness, and slightly convergent or divergent channel geometry on the model response. It is shown that physiological allowable changes in the latter three device parameters alone will not be sufficient to generate the desired reduction in fundamental frequency. However, their effects are quantified and it is shown that membrane stiffness and included angle should be considered in future designs.  相似文献   

13.
Most tissue-engineered cartilage constructs are more compliant than native articular cartilage (AC) and are poorly integrated to the surrounding tissue. To investigate the effect of an implanted tissue-engineered construct (TEC) with these inferior properties on the mechanical environment of both the engineered and adjacent native tissues, a finite element study was conducted. Biphasic swelling was used to model tibial cartilage and an implanted TEC with the material properties of either native tissue or a decreased elastic modulus and fixed charged density. Creep loading was applied with a rigid impermeable indenter that represented the femur. In comparison with an intact joint, compressive strains in the transplant, surface contact stress in the adjacent native AC and load partitioning between different phases of cartilage were affected by inferior properties of TEC. Results of this study may lead to a better understanding of the complex mechanical environment of an implanted TEC.  相似文献   

14.
A three-dimensional (3D) knee joint computational model was developed and validated to predict knee joint contact forces and pressures for different degrees of malalignment. A 3D computational knee model was created from high-resolution radiological images to emulate passive sagittal rotation (full-extension to 65°-flexion) and weight acceptance. A cadaveric knee mounted on a six-degree-of-freedom robot was subjected to matching boundary and loading conditions. A ligament-tuning process minimised kinematic differences between the robotically loaded cadaver specimen and the finite element (FE) model. The model was validated by measured intra-articular force and pressure measurements. Percent full scale error between FE-predicted and in vitro-measured values in the medial and lateral compartments were 6.67% and 5.94%, respectively, for normalised peak pressure values, and 7.56% and 4.48%, respectively, for normalised force values. The knee model can accurately predict normalised intra-articular pressure and forces for different loading conditions and could be further developed for subject-specific surgical planning.  相似文献   

15.
16.
Many studies have investigated the effect of different parameters of the endodontically restored tooth on its final strength, using in vitro tests and model simulations. However, the differences in the experimental set-up or modelling conditions and the limited number of parameters studied in each case prevent us from obtaining clear conclusions about the relative importance of each parameter. In this study, a validated 3D biomechanical model of the restored tooth was used for an exhaustive sensitivity analysis. The individual influence of 20 different parameters on the mechanical performance of an endodontic restoration with prefabricated posts was studied. The results bring up the remarkable importance of the loading angle on the final restoration strength. Flexural loads are more critical than compressive or tensile loads. Young's modulus of the post and its length and diameter are the most influential parameters for strength, whereas other parameters such as ferrule geometry or core and crown characteristics are less significant.  相似文献   

17.
Computational implementation of physical and physiologically realistic constitutive models is critical for numerical simulation of soft biological tissues in a variety of biomedical applications. It is well established that the highly nonlinear and anisotropic mechanical behaviors of soft tissues are an emergent behavior of the underlying tissue microstructure. In the present study, we have implemented a structural constitutive model into a finite element framework specialized for membrane tissues. We noted that starting with a single element subjected to uniaxial tension, the non-fibrous tissue matrix must be present to prevent unrealistic tissue deformations. Flexural simulations were used to set the non-fibrous matrix modulus because fibers have little effects on tissue deformation under three-point bending. Multiple deformation modes were simulated, including strip biaxial, planar biaxial with two attachment methods, and membrane inflation. Detailed comparisons with experimental data were undertaken to insure faithful simulations of both the macro-level stress–strain insights into adaptations of the fiber architecture under stress, such as fiber reorientation and fiber recruitment. Results indicated a high degree of fidelity and demonstrated interesting microstructural adaptions to stress and the important role of the underlying tissue matrix. Moreover, we apparently resolve a discrepancy in our 1997 study (Billiar and Sacks, 1997. J. Biomech. 30 (7), 753–756) where we observed that under strip biaxial stretch the simulated fiber splay responses were not in good agreement with the experimental results, suggesting non-affine deformations may have occurred. However, by correctly accounting for the isotropic phase of the measured fiber splay, good agreement was obtained. While not the final word, these simulations suggest that affine fiber kinematics for planar collagenous tissues is a reasonable assumption at the macro level. Simulation tools such as these are imperative in the design and simulation of native and engineered tissues.  相似文献   

18.
A three-dimensional finite element model is developed for the simulation of the sound transmission through the human auditory periphery consisting of the external ear canal, middle ear and cochlea. The cochlea is modelled as a straight duct divided into two fluid-filled scalae by the basilar membrane (BM) having an orthotropic material property with dimensional variation along its length. In particular, an active feed-forward mechanism is added into the passive cochlear model to represent the activity of the outer hair cells (OHCs). An iterative procedure is proposed for calculating the nonlinear response resulting from the active cochlea in the frequency domain. Results on the middle-ear transfer function, BM steady-state frequency response and intracochlear pressure are derived. A good match of the model predictions with experimental data from the literatures demonstrates the validity of the ear model for simulating sound pressure gain of middle ear, frequency to place map, cochlear sensitivity and compressive output for large intensity input. The current model featuring an active cochlea is able to correlate directly the sound stimulus in the ear canal with the vibration of BM and provides a tool to explore the mechanisms by which sound pressure in the ear canal is converted to a stimulus for the OHCs.  相似文献   

19.
Being seated for long periods, while part of many leisure or occupational activities, can lead to discomfort, pain and sometimes health issues. The impact of prolonged sitting on the body has been widely studied in the literature, with a large number of human-body finite element models developed to simulate sitting and assess seat-induced discomfort or to investigate the biomechanical factors involved. Here, we review the finite element models developed to investigate sitting discomfort or risk of pressure sores. Our study examines finite element models from twenty-seven papers, seventeen dedicated to assessing seating discomfort and ten dedicated to investigating pressure ulcers caused by prolonged sitting. The models’ mesh composition and material properties are found to differ widely. These models share a lack of validation and generally make little allowance for anthropometric diversity.  相似文献   

20.
A finite element analysis (FEA) modeling technique has been developed to characterize how varying the orientation of the patellar tendon influences the patellofemoral pressure distribution. To evaluate the accuracy of the technique, models were created from MRI images to represent five knees that were previously tested in vitro to determine the influence of hamstrings loading on patellofemoral contact pressures. Hamstrings loading increased the lateral and posterior orientation of the patellar tendon. Each model was loaded at 40°, 60°, and 80° of flexion with quadriceps force vectors representing the experimental loading conditions. The orientation of the patellar tendon was represented for the loaded and unloaded hamstrings conditions based on experimental measures of tibiofemoral alignment. Similar to the experimental data, simulated loading of the hamstrings within the FEA models shifted the center of pressure laterally and increased the maximum lateral pressure. Significant (p < 0.05) differences were identified for the center of pressure and maximum lateral pressure from paired t-tests carried out at the individual flexion angles. The ability to replicate experimental trends indicates that the FEA models can be used for future studies focused on determining how variations in the orientation of the patellar tendon related to anatomical or loading variations or surgical procedures influence the patellofemoral pressure distribution.  相似文献   