首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for simultaneous quantitative determination of valproic acid and three major metabolites (3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid) in human plasma. The analytes and internal standard were isolated from 200 μL samples by solid phase extraction using a ZORBAX SB-C? column (3.5 μm, 2.1×100 mm) with an isocratic mobile phase consisting of methanol-10mM ammonium acetate (80:20, v/v) containing 0.1% formic acid at a flow rate of 0.3 mL/min. The method had a chromatographic total run time of 2.0 min. The lower limit of quantification of valproic acid, 3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid of the method was 2030, 51.5, 50.15 and 51.25 ng/mL, respectively. The method was linear for valproic acid and the three metabolites with correlation coefficients >0.995 for all analytes. The intra-day and inter-day accuracy and precision of the assay were less than 15.0%. This analytical method was successfully used to assay plasma concentrations of valproic acid and the three metabolites in human plasma from epileptic patients.  相似文献   

2.
A sensitive assay using high-performance liquid chromatography tandem mass spectrometry (MS/MS) has been established for the quantitative analysis of cytochrome P450 form-specific activities using warfarin as a probe substrate. Four metabolites, 6-, 7-, 8-, and 10-hydroxywarfarin, were chromatographically resolved within 10 min using gradient mobile phases. The mass spectrometry was operated under negative ionization mode. The MS/MS product ion spectra of warfarin and the metabolites were generated using collision-activated dissociation and interpreted. The abundant product ions of the metabolites were selected for quantification applying multiple reaction monitoring. Quantification was based on a quadratic or power curve of the peak area ratio of the metabolite over the internal standard against the respective concentration of the metabolite. This assay has been validated from 2 to 1000 nM for 10-hydroxywarfarin and from 2 to 5000 nM for 6-, 7-, and 8-hydroxywarfarin and successfully applied to evaluate cytochrome P450-mediated drug-drug interactions in vitro using human hepatocytes and liver microsomal preparations.  相似文献   

3.
A new on-line, rapid and sensitive column-switch LC/MS/MS method to measure nelfinavir (NFV), an HIV-1 protease inhibitor, and its major metabolite (M1) in rat plasma was developed. Rat plasma containing the analytes and the internal standard was treated with acetonitrile and the supernatant was processed through an on-line extraction and an analytical columns, with a column-switch device. ESI-LC/MS with multiple reaction monitors for appropriate analytes was performed. This assay gave a limit of quantitation (LOQ) of <1 ng/mL for the analytes with 5 min run time. The within-run and between-run precisions were <12 and <10%, respectively. This analytical method was successfully applied to a study to correlate changes in maternal and placental NFV plasma concentrations in rats following NFV exposure in utero.  相似文献   

4.
In the present work, a high-throughput LC/MS/MS method using a Chromolith RP-18 (50 mm x 4.6 mm) monolithic column was developed and partially validated for the determination of bupropion (BUP), an anti-depressant drug, and its metabolites, hydroxybupropion and threo-hydrobupropion (TB), in human, mouse, and rat plasma. A modern integrated liquid chromatograph and an LC/MS/MS system with a TurboIonSpray (TIS) interface were used for the positive electrospray selected reaction monitoring (SRM) LC/MS analyses. Spiked control plasma calibration standards and quality control (QC) samples were extracted by semi-automated 96-well liquid-liquid extraction (LLE) using ethyl acetate. A mobile phase consisting of 8mM ammonium acetate-acetonitrile (55:45, v/v) delivered isocratically at 5 ml/min, and split post-column to 2 ml/min directed to the TIS, provided the optimum conditions for the chromatographic separation of bupropion and its metabolites within 23s. The isotope-labeled D(6)-bupropion and D(6)-hydroxybupropion were used as internal standards. The method was linear over a concentration range of 0.25-200 ng/ml (bupropion and threo-hydrobupropion), and 1.25-1000 ng/ml (hydroxybupropion). The intra- and inter-day assay accuracy and precision were within 15% for all analytes in each of the biological matrices. The monolithic column performance as a function of column backpressure, peak asymmetry, and retention time reproducibility was adequately maintained over 864 extracted plasma injections.  相似文献   

5.
H Kindahl 《Prostaglandins》1977,13(4):619-629
[5,6,8,9,11,12,14,15-3H8]-Thromboxane B2 was injected into the saphenous vein of female cynomolgus monkeys, and blood samples were withdrawn from the contralateral saphenous vein. The compound was eliminated from the circulation with a half-life of about 10 min after an initial rapid disappearance. Some more polar products appeared with time, and also small amounts of material less polar than thromboxane B2; however, the dominating compound in all blood samples was unconverted thromboxane B2. About 45% of the given dose of tritium was excreted into urine in 48 hrs. Several metabolites of thromboxane B2 were found. The major urinary metabolite was identified as dinorthromboxane B2 (about 32% of urinary radioactivity). Unconverted thromboxane B2 was also found in considerable amounts (13% of urinary radioactivity). It is concluded that 1) dehydrogenation at C-12 is not a major pathway in the degradation of this compound, in contrast to metabolism at the corresponding C-15 alcohol group of prostaglandins; 2) after having gained access to the circulation, thromboxane B2 is the main circulating compound; however, assay of thromboxane B2 in plasma will be complicated or precluded by large artifactual production of the compound by platelets during sample collection.  相似文献   

6.
For a pharmacokinetic-pharmacodynamic study in opioid tolerant patients, who were treated with heroin in combination with methadone, a liquid chromatographic assay with tandem mass spectrometry detection (LC-MS/MS) was developed for the simultaneous determination of heroin, methadone, heroin metabolites 6-monoacetylmorphine, morphine, and morphine-6 and 3-glucuronide and methadone metabolite EMDP. To detect any abuse of substances besides the prescribed opioids the assay was extended with the detection of cocaine, its metabolites benzoylecgonine and norcocaine and illicit heroin adulterants acetylcodeine and codeine. Heroin-d6, morphine-d3, morphine-3-glucuronide-d3 and methadone-d9 were used as internal standards. The sample pre-treatment consisted of solid phase extraction using mixed mode sorbent columns (MCX Oasis). Chromatographic separation was performed at 25 degrees C on a reversed phase Zorbax column with a gradient mobile phase consisting of ammonium formate (pH 4.0) and acetonitrile. The run time was 15 min. MS with relatively mild electrospray ionisation under atmospheric pressure was applied. The triple quadrupole MS was operating in the positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over a concentration range of 5-500 ng/mL for all analytes. The total recovery of heroin varied between 86 and 96% and of the heroin metabolites between 76 and 101%. Intra-assay and inter-assay accuracy and precision of all analytes were always within the designated limits (< or =20% at lower limit of quantification (LLQ) and < or =15% for other samples). This specific and sensitive assay was successfully applied in pharmacokinetic studies with medically prescribed heroin and toxicological cases.  相似文献   

7.
In this study, a tandem LC-MS (Waters Xevo TQ) MRM-based MS method was developed for rapid, broad profiling of hydrophilic metabolites from biological samples, in either positive or negative ion modes without the need for an ion pairing reagent, using a reversed-phase pentafluorophenylpropyl (PFPP) column. The developed method was successfully applied to analyze various biological samples from C57BL/6 mice, including urine, duodenum, liver, plasma, kidney, heart, and skeletal muscle. As result, a total 112 of hydrophilic metabolites were detected within 8 min of running time to obtain a metabolite profile of the biological samples. The analysis of this number of hydrophilic metabolites is significantly faster than previous studies. Classification separation for metabolites from different tissues was globally analyzed by PCA, PLS-DA and HCA biostatistical methods. Overall, most of the hydrophilic metabolites were found to have a "fingerprint" characteristic of tissue dependency. In general, a higher level of most metabolites was found in urine, duodenum, and kidney. Altogether, these results suggest that this method has potential application for targeted metabolomic analyzes of hydrophilic metabolites in a wide ranges of biological samples.  相似文献   

8.
There is increasing evidence that the clinical efficacy of tamoxifen, the first and most widely used targeted therapy for estrogen-sensitive breast cancer, depends on the formation of the active metabolites 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen (endoxifen). Large inter-individual variability in endoxifen plasma concentrations has been observed and related both to genetic and environmental (i.e. drug-induced) factors altering CYP450s metabolizing enzymes activity. In this context, we have developed an ultra performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) requiring 100 μL of plasma for the quantification of tamoxifen and three of its major metabolites in breast cancer patients. Plasma is purified by a combination of protein precipitation, evaporation at room temperature under nitrogen, and reconstitution in methanol/20 mM ammonium formate 1:1 (v/v), adjusted to pH 2.9 with formic acid. Reverse-phase chromatographic separation of tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen is performed within 13 min using elution with a gradient of 10 mM ammonium formate and acetonitrile, both containing 0.1% formic acid. Analytes quantification, using matrix-matched calibration samples spiked with their respective deuterated internal standards, is performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of relative matrix effects variability, as well as tamoxifen and metabolites short-term stability in plasma and whole blood. The method is precise (inter-day CV%: 2.5-7.8%), accurate (-1.4 to +5.8%) and sensitive (lower limits of quantification comprised between 0.4 and 2.0 ng/mL). Application of this method to patients' samples has made possible the identification of two further metabolites, 4'-hydroxy-tamoxifen and 4'-hydroxy-N-desmethyl-tamoxifen, described for the first time in breast cancer patients. This UPLC-MS/MS assay is currently applied for monitoring plasma levels of tamoxifen and its metabolites in breast cancer patients within the frame of a clinical trial aiming to assess the impact of dose increase on tamoxifen and endoxifen exposure.  相似文献   

9.
High pressure liquid chromatographic (HPLC) analysis of plasma taken over 8 h from ten normal male subjects medicated with 120 mg of trilostane revealed that the drug is rapidly metabolised into at least one metabolite, 17-keto trilostane. Both compounds were detected in the blood stream at concentrations greater than 2 X 10(-7) M within an hour and were cleared from the blood by 6-8 h. Approximately 3 times the concentration of metabolite was detected compared to the parent compound in most samples analysed. There were large subject to subject variations in the handling of drug. Standard curves of pure 17-keto trilostane and trilostane were parallel as assessed by cytochemical bioassay. This assay is based upon the inhibition of 3 beta-hydroxysteroid dehydrogenase activity in unfixed tissue sections of the dioestrous rat ovary. The relative potency of the metabolite compared to trilostane was 1.71 (95% confidence 1.5-2.0) over the dose range 0.15-1.5 microM. Thus, the metabolite may be the major active agent when trilostane is administered for clinical purposes. In a further 4 volunteers, who also received 120 mg trilostane and were sampled over an 8 h period, plasma was analysed independently by HPLC and cytochemical assays. In the majority of cases the bioactivity recorded (relative to a trilostane standard curve) was substantially higher than the molar sum of circulating trilostane and 17-keto-trilostane (as assessed by HPLC). However, if the relative potency of 17-keto-trilostane is taken into consideration, correlation between the two assays was excellent (r = 0.947, n = 18, P less than 0.001). This also suggests that no further active metabolites were present in the plasma samples. The drug profiles seen in the second study were essentially the same as described for the first 10 volunteers. The combination of a bioassay, which detects trilostane-like bioactivity, and HPLC, which reveals the type of metabolism, should aid our understanding of the clinical value of this potentially important drug.  相似文献   

10.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-dammarane-3beta,12beta,20,25-tetrol (25-OH-PPD) in rat. Ginsenoside Rh(2) was employed as an internal standard. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. The mobile phase consisted of methanol-acetonitrile-10 mmol/l aqueous ammonium acetate (42.5:42.5:15, v:v:v), which was pumped at 0.4 ml/min. The analytical column (50 mm x 2.1 mm i.d.) was packed with Venusil XBP C8 material (3.5 microm). The standard curve was linear from 10 to 3000 ng/ml. The assay was specific, accurate (accuracy between -1.19 and 2.57% for all quality control samples), precise and reproducible (within- and between-day precisions measured as relative standard deviation were <5% and <7%, respectively). 25-OH-PPD in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 6h. The method had a lower limit of quantitation of 10 ng/ml, which offered a satisfactory sensitivity for the determination of (25-OH-PPD) in plasma. This quantitation method was successfully applied to pharmacokinetic studies of 25-OH-PPD after both an oral and an intravenous administration to rats and the absolute bioavailability is 64.8+/-14.3%.  相似文献   

11.
Alpha- and gamma-tocopherol (alpha- and gamma-T, respectively) metabolite analysis is of key relevance in the study of vitamin E metabolism. Whilst there is information on urinary excretion of the two major metabolites of these vitamin E homologues, namely the 2,5,7,8-tetramethyl-2-(beta-carboxyethyl)-6-hydroxychroman (alpha-CEHC) and 2,7,8-trimethyl-2-(beta-carboxyethyl)-6-hydroxychroman (gamma-CEHC), their concentration and response to supplements in plasma remains poorly investigated. In this study we describe a gas chromatography-mass spectrometry (GC/MS)-based assay to measure both alpha- and gamma-T and their corresponding CEHC metabolites in human plasma. As an example of the application of this method we report data obtained following the supplemention of two healthy volunteers with 100 mg of deuterium-labeled gamma-T acetate (d(2)-gamma-TAC). Under routine analytical conditions a good linearity in the range 0.0025--1 microM was observed for both the alpha- and gamma-CEHC deuterated standards. In plasma samples, the detection limit for alpha- and gamma-CEHC was 2.5 and 5 nmol/l, respectively. The minimum amount of plasma required for the assay was 500 microl. The plasma concentrations of alpha-CEHC and gamma-CEHC in unsupplemented healthy subjects were 12.6 +/-7.5 and 160.7 +/- 44.9 nmol/l, respectively. In the two volunteers supplemented with 100 mg of d(2)-gamma-TAC, plasma d(2)-gamma-T concentrations increased 250 to 450-fold 6 h postsupplementation. Plasma and urinary d(2)-gamma-CEHC concentrations increased 20 to 40-fold 9--12 h postsupplementation. Interestingly, the acute increase in d(2) gamma-T did not significantly affect the baseline plasma concentrations of d(0)-gamma-T and only slight lowered alpha-T concentrations. Likewise, plasma alpha-CEHC levels were not influenced and urinary excretion of alpha-CEHC were unaltered. This GC/MS method provides a versatile and accurate mean for assessing carboxyethyl-hydroxychroman metabolites of vitamin E in plasma.  相似文献   

12.
BMS-068645 is a selective adenosine 2A agonist that contains a methyl ester group which undergoes esterase hydrolysis to its acid metabolite. To permit accurate determinations of circulating BMS-068645 and its acid metabolite, blood samples must be rapidly stabilized at the time of collection. A sensitive, rapid and specific liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantitation of BMS-068645 and its acid metabolite in human plasma has been developed and validated using diisopropyl fluorophosphate (DFP) as the esterase inhibitor to prevent BMS-068645 from converting to its acid metabolite. The D(5)-stable isotope labeled analogs of BMS-068645 and its metabolite were used as the internal standards (IS). Analytes and IS in plasma containing 20 mM DFP were acidified and extracted into methyl tert-butyl ether. The liquid-liquid extraction effectively eliminated the strong matrix effect caused by the esterase inhibitor. The chromatographic separation was achieved on a Waters Atlantis C18 column with a run time of 4 min. Detection was performed on a Sciex API 4000 with positive ion electrospray mode (ESI/MS/MS), monitoring the ion transitions m/z 487>314 and 473>300 for BMS-068645 and its acid metabolite, respectively. The method was validated over the range from 0.020 to 10.0 ng/mL for BMS-068645 and 0.050 to 10.0 ng/mL for its acid metabolite. Inter- and intra-run precision for the quality control samples during validation were less than 8.7% and 4.0%, respectively, for the two analytes. The assay accuracy was within +/-5.4% of the nominal values. The esterase inhibitor effectively stabilized BMS-068645 during blood collection and storage. Blood collection tubes containing DFP were easily prepared and used at the clinical sites and could be stored at -30 degrees C for 3 months. This method demonstrated adequate sensitivity, specificity, accuracy, precision, stability and ruggedness to support the analysis of human plasma samples in pharmacokinetic studies.  相似文献   

13.
Ebastine (CAS 90729-43-4) is an antiallergic agent which selectively and potently blocks histamine H1-receptors in vivo. A simple and sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of ebastine and its two oxidized metabolites, carebastine (CAS 90729-42-3) and hydroxyebastine (M–OH), in human plasma. After a pretreatment of plasma sample by solid-phase extraction, ebastine and its metabolites were analyzed on an HPLC system with ultraviolet detection at 254 nm. Chromatography was performed on a cyano column (250×4.0 mm I.D.) at 40 °C with the mobile phase of acetonitrile–methanol–0.012 M ammonium acetate buffer (20:30:48, v/v/v) at a flow rate of 1.2 ml/min. Accurate determinations were possible over the concentration range of 3–1000 ng/ml for the three compounds using 1 ml plasma samples. The intra- and inter-day assay accuracy of this method were within 100±15% of nominal values and the precision did not exceed 12.4% of relative standard deviation. The lower limits of quantitation were 3 ng/ml for ebastine and its metabolites in human plasma. This method was satisfactorily applied to the determination of ebastine and its two oxidized metabolites in human plasma after oral administration of ebastine.  相似文献   

14.
The simultaneous isolation and determination of mitoxantrone (Novantrone ®) and its two known metabolites (the mono- and dicarboxylic metabolites) were carried out using a high-performance liquid chromatographic (HPLC) system equipped with an automatic pre-column-switching system that permits drug analysis by direct injection of biological samples. Plasma or urine samples were injected directly on to an enrichment pre-column flushed with methanol-water (5:95, v/v) as the mobile phase. The maximum amount of endogenous water-soluble components was removed from biological samples within 9 min. Drugs specifically adsorbed on the pre-column were back-flushed on to an analytical column (Nucleosil C18, 250x4.6 mm I.D.) with 1.6 M ammonium formate buffer (pH 4.0) (2.5% formic acid) containing 20% acetonitrile. Detection was effected at 655 nm. Chromatographic analysis was performed within 12 min. The detection limit of the method was about 4 ng/ml for urine and 10 ng/ml for plasma samples. The precision ranged from 3 to 11% depending on the amount of compound studied. This technique was applied to the monitoring of mitoxantrone in plasma and to the quantification of the unchanged compound and its two metabolites in urine from patients receiving 14 mg/m2 of mitoxantrone by intravenous infusion for 10 min.  相似文献   

15.
A simple, selective, sensitive and precise high-performance liquid chromatographic plasma assay for the prokinetic drug cisapride is described. Alkalinised samples of plasma (100 μl) were extracted with 1.0 ml of 10% (v/v) isopropanol in chloroform, dried, redissolved in mobile phase and injected. Chromatography was performed at 20°C by pumping a mobile phase of acetonitrile (370 ml) in pH 5.2, 0.02 M phosphate buffer (630 ml) at 1.0 ml/min through a C8 Symmetry column. Cisapride and the internal standard were detected by fluorescence monitoring at 295 nm (excitation) and 350 nm (emission), and were eluted 5 min and 8 min, respectively, after injection. Calibration plots in bovine serum albumin (3% w/v) were linear (r > 0.999) from 5 to 250 ng/ml. Intra-day and inter-day precision (C.V.) was 9.5%, or less, and the accuracy was within 5.5% of the nominal concentration over the range 8–200 ng/ml. Total assay recovery was above 82%. Endogenous plasma components, major cisapride metabolite (norcisapride), and other durgs used in neonatal pharmacotherapeutics did not interfere.  相似文献   

16.
A rapid and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated for quantification of cyclizine and its main metabolite norcyclizine in human plasma. Samples were prepared by protein precipitation with acetonitrile and cinnarizine was used as internal standard (recovery >87%). The analytes were eluted from a C8 50 mm×2.0 mm analytical column using a linear gradient of methanol and 0.05% formic acid with a total analysis time of 4 min. Analytes were detected by MS/MS using electrospray ionisation in the positive mode with multiple reactions monitoring (MRM) of the precursor ion/product ion transitions 267.2/167.2 for cyclizine and 253.2/167.2 for norcyclizine. Matrix effects were negligible. Standard curves for cyclizine and norcyclizine were linear (r(2)≥0.996) over the range 2-200 ng/mL, with 2 ng/mL representing the lower limit of quantification. Relative standard deviations were <14% for intra- and inter-day precision and the accuracy was within ±8%. The assay was successfully applied to a clinical study.  相似文献   

17.
A rapid, sensitive and specific method was developed and validated using liquid chromatography-tandem mass spectrometry (LC/MS/MS) for determination of gefitinib in human plasma and mouse plasma and tissue. Sample preparation involved a single protein precipitation step by the addition of 0.1 mL of plasma or a 200 mg/mL tissue homogenate diluted 1/10 in human plasma with 0.3 mL acetonitrile. Separation of the compounds of interest, including the internal standard (d8)-gefitinib, was achieved on a Waters X-Terra C18 (50 mm x 2.1 mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile-water (70:30, v/v) containing 0.1% formic acid and isocratic flow at 0.15 mL/min for 3 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 1-1000 ng/mL for the human plasma samples and 5-1000 ng/mL for mouse plasma and tissue samples with values for the coefficient of determination of > 0.99. The values for both within- and between-day precision and accuracy were well within the generally accepted criteria for analytical methods (< 15%). This method was subsequently used to measure concentrations of gefitinib in mice following administration of a single dose of 150 mg/kg intraperitoneally and in cancer patients receiving an oral daily dose of 250 mg.  相似文献   

18.
A simple, sensitive and specific LC-MS/MS method for the simultaneous determination of sulforaphane (SFN) and its major metabolites, the glutathione (SFN-GSH) and N-acetyl cysteine conjugates (SFN-NAC) from biological matrices was developed and validated. The assay procedure involved solid-phase extratcion of all three analytes from rat intestinal perfusate using C2 extraction cartridges, whereas from rat plasma, metabolites were extracted by solid-phase extraction and SFN was extracted by liquid-liquid extraction with ethyl acetate. Chromatographic separation of SFN, SFN-GSH and SFN-NAC was achieved on a C8 reverse phase column with a mobile phase gradient (Mobile Phase A: 10mM ammonium acetate buffer, pH: 4.5 and Mobile Phase B: acetonitrile with 0.1% formic acid) at a flow rate of 0.3 mL/min. The Finnigan LCQ LC-MS/MS was operated under the selective reaction monitoring mode using the electrospray ionization technique in positive mode. The nominal retention times for SFN-GSH, SFN-NAC and SFN were 8.4, 11.0, and 28.2 min,, respectively. The method was linear for SFN and its metabolites with correlation coefficients >0.998 for all analytes. The limit of quantification was 0.01-0.1 microm depending on analyte and matrix, whereas the mean recoveries from spiked plasma and perfusate samples were approximately 90%. The method was further validated according to U.S. Food and Drug Administration guidance in terms of accuracy and precision. Stability of compounds was established in a battery of stability studies, i.e., bench top, auto-sampler and long-term storage stability as well as freeze/thaw cycles. The utility of the assay was confirmed by the analysis of intestinal perfusate and plasma samples from single-pass intestinal perfusion studies with mesenteric vein cannulation in rats.  相似文献   

19.
Analytical methods for the determination of ximelagatran, an oral direct thrombin inhibitor, its active metabolite melagatran, and intermediate metabolites, melagatran hydroxyamidine and melagatran ethyl ester, in biological samples by liquid chromatography (LC) positive electrospray ionization mass spectrometry (MS) using selected reaction monitoring are described. Isolation from human plasma was achieved by solid-phase extraction on octylsilica. Analytes and isotope-labelled internal standards were separated by LC utilising a C(18) analytical column and a mobile phase comprising acetonitrile-4 mmol/l ammonium acetate (35:65, v/v) containing 0.1% formic acid, at a flow-rate of 0.75 ml/min. Absolute recovery was approximately 80% for ximelagatran, approximately 60% for melagatran ethyl ester and >90% for melagatran and melagatran hydroxyamidine. Limit of quantification was 10 nmol/l, with a relative standard deviation <20% for each analyte and <5% above 100 nmol/l. Procedures for determination of these analytes in human urine and breast milk, plus whole blood from rat and mouse are also described.  相似文献   

20.
A bioanalytical method was developed for the quantitation of methadone (MTD) and its primary metabolite, (EDDP) in plasma. The extraction step was performed within a capillary column packed with large particles (35x0.3 mm I.D.; d(p) 30 micrometer) at high flow-rate conditions (450 microliter/min). The separation was performed on a microbore analytical column (55x2 mm I.D.; d(p) 3 micrometer) coupled to a mass spectrometer (MS). This procedure was based on a column-switching unit. Analytes of interest were retained on the precolumn by hydrophobic interactions and backflushed from the precolumn to the analytical column. The detection was carried out with a MS single quadrupole equipped with an electrospray interface. The total analysis time was 6 min. The limits of quantification were evaluated at 10 and 25 ng/ml for MTD and EDDP, respectively. At this level, good accuracies were obtained for both analytes with repeatability values less than 18%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号