Ligament balancing during total knee replacement (TKR) is receiving increased attention due to its influence on resulting joint kinematics and laxity. We employed a novel in vitro technique to measure the kinematics and laxity of TKR implants during gait, and measured how these characteristics are influenced by implant shape and soft tissue balancing, simulated using virtual ligaments. Compared with virtual ligaments that were equally balanced in flexion and extension, the largest changes in stance-phase tibiofemoral AP and IE kinematics occurred when the virtual ligaments were simulated to be tighter in extension (tibia offset 1.0 ± 0.1 mm posterior and 3.6 ± 0.1° externally rotated). Virtual ligaments which were tight in flexion caused the largest swing-phase changes in AP kinematics (tibia offset 2.3 ± 0.2 mm), whereas ligaments which were tight in extension caused the largest swing-phase changes in IE kinematics (4.2 ± 0.1° externally rotated). When AP and IE loads were superimposed upon normal gait loads, incremental changes in AP and IE kinematics occurred (similar to laxity testing); and these incremental changes were smallest for joints with virtual ligaments that were tight in extension (in both the stance and swing phases). Two different implant designs (symmetric versus medially congruent) exhibited different kinematics and sensitivities to superimposed loads, but demonstrated similar responses to changes in ligament balancing. Our results demonstrate the potential for pre-clinical testing of implants using joint motion simulators with virtual soft tissues to better understand how ligament balancing affects implant motion.  相似文献   

2.
Previous in vivo studies have observed that current designs of posterior stabilised (PS) total knee replacements (TKRs) may be ineffective in restoring normal kinematics in Late flexion. Computer-based models can prove a useful tool in improving PS knee replacement designs. This study investigates the accuracy of a two-dimensional (2D) sagittal plane model capable of predicting the functional sagittal plane kinematics of PS TKR implanted knees against direct in vivo measurement. Implant constraints are often used as determinants of anterior–posterior tibio-femoral positioning. This allowed the use of a patello-femoral modelling approach to determine the effect of implant constraints. The model was executed using motion simulation software which uses the constraint force algorithm to achieve a solution. A group of 10 patients implanted with Scorpio PS implants were recruited and underwent fluoroscopic imaging of their knees. The fluoroscopic images were used to determine relative implant orientation using a three-dimensional reconstruction method. The determined relative tibio-femoral orientations were then input to the model. The model calculated the patella tendon angles (PTAs) which were then compared with those measured from the in vivo fluoroscopic images. There were no significant differences between the measured and calculated PTAs. The average root mean square error between measured and modelled ranged from 1.17° to 2.10° over the flexion range. A sagittal plane patello-femoral model could conceivably be used to predict the functional 2D kinematics of an implanted knee joint. This may prove particularly useful in optimising PS designs.  相似文献   

3.
Few in-vitro studies have investigated changes in kinematics caused by total knee replacement (TKR) implantation. The advent of surgical navigation systems allows implant position to be measured accurately and the effects of alteration of TKR position and alignment investigated. A test rig and protocol were developed to compare the kinematics of TKR-implanted knees for different femoral component positions. The TKR was implanted and the component positions documented using a navigation system. The quadriceps was tensed and the knees were flexed and extended manually. Torques and drawer forces were applied to the tibia during knee flexion–extension, while recording the kinematics with the navigation system. The implant was removed and replaced on an intramedullary fixation that allowed proximal–distal, and internal–external rotation of the femoral component without conducting a repeated arthrotomy on the knee. The implant was repositioned using the navigation system to reproduce the previously achieved normally navigated position and the kinematics were recorded again. The recorded kinematics of the knee were not significantly different between both normal implantation and intramedullary remounting for tibial internal–external rotation, varus–valgus angulation, or posterior drawer, at any angle of knee flexion examined. Anterior drawer was increased approximately 2.5 mm across the range 20–35° knee flexion (p<0.05), but was otherwise not significantly different. This method of navigating implant components and of moving them within the closed knee (thus avoiding artefactual effects of repeated soft tissue manipulations) can now be used to quantify the effect on kinematics of alteration of the position of the femoral component.  相似文献   

4.
The purpose of this study was to determine the stability and accuracy of active knee joint velocity replication methods in healthy subjects. We used a repeated measures design with 14 healthy volunteers. Measures of velocity replication were performed in two ranges of knee joint flexion (0°–30° and 60°–90°), across four testing velocities (5, 10, 15, and 30°/s) in two movement directions (flexion and extension). Statistical analysis included intraclass correlation coefficients (ICCs; 2, k) and associated standard error of the measures calculated between day 1 and 2. We performed z-tests between all possible combinations of ICC pairs using Fisher’s Z transformations to determine if any significant differences existed between observed ICCs. We also calculated correlation ratios (η2) to explain the source of variability in the calculated ICCs. To assess measurement accuracy, we calculated constant error and absolute error between criterion and replication velocities. Results on ICCs and standard error of the measurements (SEMs) ranged from r = ?0.44 ± 7.00 to 0.88 ± 0.72°/s. Calculated z-tests indicated six paired ICCs were significantly different (?p < 0.1). In all six pairs, the faster test velocity had a lower ICC magnitude. The η2 calculations demonstrated that inconsistent performance between day 1 and 2 caused the low ICC magnitudes observed with faster testing velocities. Significantly more absolute error occurred at 30 and 15°/s compared with 5°/s. Significantly less constant error was observed for 30°/s compared with 15°/s. A significant direction by range of motion interaction indicated less constant error for flexion movements in the 60°–90° range of motion (ROM) as compared with extension movements in either ROM. Healthy individuals could actively replicate slower criterion velocities in the mid and end ranges of knee joint motion in both movement directions with an acceptable amount of consistency and accuracy. The data support the use of velocity replication in future investigations on proprioceptive function.  相似文献   

5.
Fluoroscopic imaging is commonly used for assessing relative motions of orthopaedic implants. One limiting factor to in vivo model-based roentgen stereophotogrammetric analysis of total knee arthroplasty is the need for 3D models of the implants.The 3D models of the implant components must be reverse-engineered, if not provided by the company, which makes this method impractical for a clinical study involving many types or sizes of implants. This study introduces a novel feature-based methodology that registers the features at the implant-bone or implant-cement interface of the components that have elementary shapes. These features include pegs with hemispherical heads, and straight, circular or curved edges located on flat faces of the box of the femoral component or the stem geometry of the tibial component. Software was developed to allow easy registration of these features through a graphical user interface. The accuracy and precision of registration for multiple flexion angles from 0 to 120 deg was determined with reference to registered poses of the implants through experiments on bone replica models and also on a cadaver specimen implanted with total knee prostheses. When compared to an equivalent bi-planar model-based registration, the results were comparable: The mean accuracy of this feature-based method was 1.45 deg and 1.03 mm (in comparison to 0.95 deg and 1.32 mm for the model-based approach), and the mean precision was 0.57 deg and 0.26 mm (in comparison to 0.42 deg and 0.44 mm for the model-based approach).The methodology and the developed software can easily accommodate different design of implants with various fixation features. This method can facilitate in vivo kinematic analysis of total knee arthroplasty by eliminating the need for 3D models of the implant components.  相似文献   

6.
Recently, high-flexion knee implants have been developed to provide for a large range of motion (ROM>120°) after total knee arthroplasty (TKA). Since knee forces typically increase with larger flexion angles, it is commonly assumed that high-flexion knee implants are subjected to larger loads than conventional knee implants. However, most high-flexion studies do not consider thigh–calf contact which occurs during high-flexion activities such as squatting and kneeling. In this study, we hypothesized that thigh–calf contact reduces the knee forces during deep knee flexion as the tibio-femoral load shifts from occurring inside the knee towards the thigh–calf contact interface. Hence, the effect of thigh–calf contact on the knee loading was evaluated using a free body diagram and a finite element model and both the knee forces and polyethylene stresses were analyzed. Thigh–calf contact force characteristics from an earlier study were included and a squatting movement was simulated. In general, we found thigh–calf contact considerably reduced both the knee forces and polyethylene stresses during deep knee flexion. At maximal flexion (155°), the compressive knee force decreased from 4.89 to 2.90 times the bodyweight (BW) in case thigh–calf contact was included and the polyethylene contact stress at the tibial post decreased from 49.3 to 28.1 MPa. Additionally, there was a clear correlation between a subject's thigh and calf circumference and the force reduction at maximal flexion due to thigh–calf contact (R=0.89). The findings presented in this study can be used to optimize the mechanical behavior of high-flexion total knee arthroplasty designs.  相似文献   

7.
When estimating knee kinematics from skin markers and stereophotogrammetry, multi-body optimization (MBO) has provided promising results for reducing soft tissue artefacts (STA), but can still be improved. The goal of this study was to assess the performance of MBO with subject-specific knee models at high knee flexion angles (up to 110°) against knee joint kinematics measured by magnetic resonance imaging. Eight subjects were recruited. MBO with subject-specific knee models was more effective in compensating STA compared to no kinematic and spherical constraints, in particular for joint displacements. Moreover, it seems to be more reliable over large ranges of knee flexion angle. The ranges of root mean square errors for knee rotations/displacements were 3.0°–9.2°/1.3–3.5 mm for subject-specific knee models, 6.8°–8.7°/6.0–12.4 mm without kinematic constraint and 7.1°–9.8°/4.9–12.5 mm for spherical constraints.  相似文献   

8.
A phantom study was conducted to determine bias in motion and bias at zero motion of radiostereometric analysis (RSA) for evaluating implant relative displacement in reverse total shoulder arthroplasty (RTSA). A Sawbones shoulder phantom was fitted with a RTSA implant set and 13 tantalum markers. The model was fixed to a manual micrometer, providing controlled movements though fifteen known increments in translation and twelve increments in rotation (0.02–5.00 mm and 0.1–6.0°), along each translation and rotation axis. Movement between the glenoid and humerus was assessed using beads vs. beads (B/B), model vs. beads (M/B), and model vs. model (M/M) measurement methods in a model-based RSA environment. Bias in motion and bias at zero motion were defined as the difference between measured and accepted reference values, and the difference between double examinations with a theoretical displacement of zero, respectively. Bias in motion ranged from 0.054 ± 0.010 to 0.129 ± 0.014 mm and 0.076 ± 0.025 to 0.126 ± 0.025° (B/B), 0.023 ± 0.009 to 0.126 ± 0.016 mm and 0.111 ± 0.033 to 0.794 ± 0.251° (M/B), and 0.029 ± 0.010 to 0.135 ± 0.030 mm and 0.243 ± 0.088 to 0.384 ± 0.153° (M/M). Bias at zero motion ranged from 0.120 to 0.156 mm and 0.075 to 0.206° (B/B), 0.074 to 0.149 mm and 0.067 to 1.953° (M/B), and 0.069 to 0.259 mm and 0.284 to 1.273° (M/M). This is the first RSA for RTSA study, with results comparable to those validating the use of RSA for hip and knee arthroplasties (accepted as 0.05–0.50 mm and 0.15–1.15°), justifying the potential use of RSA as a tool for measuring implant displacement in the shoulder.  相似文献   

9.
Kneeling is required during daily living for many patients after total knee replacement (TKR), yet many patients have reported that they cannot kneel due to pain, or avoid kneeling due to discomfort, which critically impacts quality of life and perceived success of the TKR procedure. The objective of this study was to evaluate the effect of component design on patellofemoral (PF) mechanics during a kneeling activity. A computational model to predict natural and implanted PF kinematics and bone strains after kneeling was developed and kinematics were validated with experimental cadaveric studies. PF joint kinematics and patellar bone strains were compared for implants with dome, medialized dome, and anatomic components. Due to the less conforming nature of the designs, change in sagittal plane tilt as a result of kneeling at 90° knee flexion was approximately twice as large for the medialized-dome and dome implants as the natural case or anatomic implant, which may result in additional stretching of the quadriceps. All implanted cases resulted in substantial increases in bone strains compared with the natural knee, but increased strains in different regions. The anatomic patella demonstrated increased strains inferiorly, while the dome and medialized dome showed increases centrally. An understanding of the effect of implant design on patellar mechanics during kneeling may ultimately provide guidance to component designs that reduces the likelihood of knee pain and patellar fracture during kneeling.  相似文献   

10.
Abstract

Purpose: Skin contributes to joint position sense (JPS) at multiple joints. Altered cutaneous input at the foot can modulate gait and balance and kinesiology tape can enhance proprioception at the knee, but its effect may be dependent on existing capacity. The effect of texture at the knee, particularly in those with poor proprioception, is unknown. The aim of this study was to determine the effect of textured panels on JPS about the knee.

Materials and methods: Eighteen healthy females were seated in an adjustable chair. Their left leg (target limb) moved passively from 65° to a target of flexion (115° or 90°) or extension (40°). Their right leg (matching limb) was passively moved towards this target angle and participants indicated when their limbs felt aligned. We tested three textured panels over the knee of the matching limb and two control conditions. The target limb maintained a control panel. Directional error, absolute error and variable error in matching between limbs were calculated.

Results: On average textured panels over the knee increased JPS error compared to control pants for participants with poor JPS. These participants undershot the target at 90° of flexion significantly more with textured panels (?11°?±?3°) versus control (?7°?±?3°, p?=?0.04).

Conclusions: For participants with poor JPS accuracy, increased JPS error at 90° with a textured panel suggests these individuals utilised altered cutaneous information to adjust joint position. We propose increased error results from enhanced skin input at the knee leading to the perception of increased flexion.  相似文献   

11.
Rectus femoris transfer is frequently performed to treat stiff-knee gait in subjects with cerebral palsy. In this surgery, the distal tendon is released from the patella and re-attached to one of several sites, such as the sartorius or the iliotibial band. Surgical outcomes vary, and the mechanisms by which the surgery improves knee motion are unclear. The purpose of this study was to clarify the mechanism by which the transferred muscle improves knee flexion by examining three types of transfers. Muscle-actuated dynamic simulations were created of ten children diagnosed with cerebral palsy and stiff-knee gait. These simulations were altered to represent surgical transfers of the rectus femoris to the sartorius and the iliotibial band. Rectus femoris transfers in which the muscle remained attached to the underlying vasti through scar tissue were also simulated by reducing but not eliminating the muscle's knee extension moment. Simulated transfer to the sartorius, which converted the rectus femoris’ knee extension moment to a flexion moment, produced 32±8° improvement in peak knee flexion on average. Simulated transfer to the iliotibial band, which completely eliminated the muscle's knee extension moment, predicted only slightly less improvement in peak knee flexion (28±8°). Scarred transfer simulations, which reduced the muscle's knee extension moment, predicted significantly less (p<0.001) improvement in peak knee flexion (14±5°). Simulations revealed that improved knee flexion following rectus femoris transfer is achieved primarily by reduction of the muscle's knee extension moment. Reduction of scarring of the rectus femoris to underlying muscles has the potential to enhance knee flexion.  相似文献   

12.
13.
The aim of this study was to quantify the tibio-femoral contact point (CP) locations in healthy and osteoarthritic (OA) subjects during a weight-bearing squat using stand-alone biplanar X-ray images.Ten healthy and 9 severe OA subjects performed quasi-static squats. Bi-planar X-ray images were recorded at 0°, 15°, 30°, 45°, and 70° of knee flexion. A reconstruction/registration process was used to create 3D models of tibia, fibula, and femur from bi-planar X-rays and to measure their positions at each posture. A weighted centroid of proximity algorithm was used to calculate the tibio-femoral CP locations. The accuracy of the reconstruction/registration process in measuring the quasi-static kinematics and the contact parameters was evaluated in a validation study.The quasi-static kinematics data revealed that in OA knees, adduction angles were greater (p<0.01), and the femur was located more medially relative to the tibia (p<0.01). Similarly, the average CP locations on the medial and lateral tibial plateaus of the OA patients were shifted (6.5±0.7 mm; p<0.01) and (9.6±3.1 mm; p<0.01) medially compared to the healthy group. From 0° to 70° flexion, CPs moved 8.1±5.3 mm and 8.9±5.3 mm posteriorly on the medial and lateral plateaus of healthy knees; while in OA joints CPs moved 10.1±8.4 mm and 3.6±2.8 mm posteriorly. The average minimum tibio-femoral bone-to-bone distances of the OA joints were lower in both compartments (p<0.01).The CPs in the OA joints were located more medially and displayed a higher ratio of medial to lateral posterior translations compared to healthy joints.  相似文献   

14.
Anterior–posterior stability in an unconstrained mobile-bearing total knee arthroplasty (TKA) and one with rotational constraints is compared in a computational model based on an ASTM test. Both TKA designs dislocate at loads greater than reported maximum in vivo forces. The posterior drawer forces (mean: 3027 N vs. 1817 N) needed to induce subluxation increase with a greater anterior jump distance (12 mm vs. 7 mm; refers to the vertical height of the anterior or posterior border of the tibial insert's articulating surface). The posterior jump distance for both tested TKA differed by 1.5 mm and had minimal effect on the magnitude of the anterior drawer forces at dislocation in mid-flexion (unconstrained vs. constrained: 445 N vs. 412 N). The unconstrained insert dislocated by means of spin-out whereas in the constrained TKA the femur dislocated from the bearing during posterior drawer and the bearing from the baseplate during anterior drawer. MCL function is an important consideration during ligament balancing since a ± 10% variation in MCL tension affects dislocation forces by ± 20%. The simulation platform provided the means to investigate TKA designs in terms of anterior–posterior stability as a function of knee flexion, collateral ligament function and mechanical morphology.  相似文献   

15.
This study was performed to evaluate a dynamic multibody model developed to characterize the influence of tibial tuberosity realignment procedures on patellofemoral motion and loading. Computational models were created to represent four knees previously tested at 40°, 60°, and 80° of flexion with the tibial tuberosity in a lateral, medial and anteromedial positions. The experimentally loaded muscles, major ligaments of the knee, and patellar tendon were represented. A repeated measures ANOVA with post-hoc testing was performed at each flexion angle to compare data between the three positions of the tibial tuberosity. Significant experimental trends for decreased patella flexion due to tuberosity anteriorization and a decrease in the lateral contact force due to tuberosity medialization were reproduced computationally. The dynamic multibody modeling technique will allow simulation of function for symptomatic knees to identify optimal surgical treatment methods based on parameters related to knee pathology and pre-operative kinematics.  相似文献   

16.
Total knee arthroplasty is a well established treatment for degenerative joint disease, which is also performed as a treatment in younger and middle-aged patients who have a significant physical activity and high life expectancy. However, complications may occur due to biological responses to wear particles, as well as local and systemic hypersensitivity reactions triggered by metal ions and particles such as cobalt, chromium and molybdenum. The purpose of the study was to perform a highly demanding activities (HDA) knee wear simulation in order to compare the wear characteristics and metal ion release barrier function of a zirconium nitride (ZrN) coated knee implant, designed for patients with suspected metal ion hypersensitivity, against an uncoated knee implant made out of CoCrMo. The load profiles were applied for 5 million HDA cycles, which represent 15–30 years of in vivo service depending on the activity level of the patient. Results showed a significant wear rate reduction for the coated group (1.01 ± 0.29 mg/million cycles) in comparison with the uncoated group (2.89 ± 1.04 mg/million cycles). The zirconium nitride coating showed no sign of scratches nor delamination during the wear simulation, whereas the uncoated femurs showed characteristic wear scratches in the articulation areas. Furthermore, the metal ion release from the coated implants was reduced up to three orders of magnitude in comparison with the uncoated implants. These results demonstrate the efficiency of zirconium nitride coated knee implants to reduce wear as well as to substantially reduce metal ion release in the knee joint.  相似文献   

17.
IntroductionMusculoskeletal modeling allows insight into the interaction of muscle force and knee joint kinematics that cannot be measured in the laboratory. However, musculoskeletal models of the lower extremity commonly use simplified representations of the knee that may limit analyses of the interaction between muscle forces and joint kinematics. The goal of this research was to demonstrate how muscle forces alter knee kinematics and consequently muscle moment arms and joint torque in a musculoskeletal model of the lower limb that includes a deformable representation of the knee.MethodsTwo musculoskeletal models of the lower limb including specimen-specific articular geometries and ligament deformability at the knee were built in a finite element framework and calibrated to match mean isometric torque data collected from 12 healthy subjects. Muscle moment arms were compared between simulations of passive knee flexion and maximum isometric knee extension and flexion. In addition, isometric torque results were compared with predictions using simplified knee models in which the deformability of the knee was removed and the kinematics at the joint were prescribed for all degrees of freedom.ResultsPeak isometric torque estimated with a deformable knee representation occurred between 45° and 60° in extension, and 45° in flexion. The maximum isometric flexion torques generated by the models with deformable ligaments were 14.6% and 17.9% larger than those generated by the models with prescribed kinematics; by contrast, the maximum isometric extension torques generated by the models were similar. The change in hamstrings moment arms during isometric flexion was greater than that of the quadriceps during isometric extension (a mean RMS difference of 9.8 mm compared to 2.9 mm, respectively).DiscussionThe large changes in the moment arms of the hamstrings, when activated in a model with deformable ligaments, resulted in changes to flexion torque. When simulating human motion, the inclusion of a deformable joint in a multi-scale musculoskeletal finite element model of the lower limb may preserve the realistic interaction of muscle force with knee kinematics and torque.  相似文献   

18.
Total knee arthroplasty (TKA) is a successful procedure for osteoarthritis. However, some patients (19%) do have pain after surgery. A finite element model was developed based on boundary conditions of a knee rig. A 3D-model of an anatomical full leg was generated from magnetic resonance image data and a total knee prosthesis was implanted without patella resurfacing. In the finite element model, a restarting procedure was programmed in order to hold the ground reaction force constant with an adapted quadriceps muscle force during a squat from 20° to 105° of flexion. Knee rig experimental data were used to validate the numerical model in the patellofemoral and femorotibial joint. Furthermore, sensitivity analyses of Young’s modulus of the patella cartilage, posterior cruciate ligament (PCL) stiffness, and patella tendon origin were performed. Pearson’s correlations for retropatellar contact area, pressure, patella flexion, and femorotibial ap-movement were near to 1. Lowest root mean square error for retropatellar pressure, patella flexion, and femorotibial ap-movement were found for the baseline model setup with Young’s modulus of 5 MPa for patella cartilage, a downscaled PCL stiffness of 25% compared to the literature given value and an anatomical origin of the patella tendon. The results of the conducted finite element model are comparable with the experimental results. Therefore, the finite element model developed in this study can be used for further clinical investigations and will help to better understand the clinical aspects after TKA with an unresurfaced patella.  相似文献   

19.
Complications in the patellofemoral (PF) joint of patients with total knee replacements include patellar subluxation and dislocation, and remain a cause for revision. Kinematic measurements to assess these complications and evaluate implant designs require the accuracy of dynamic stereo-radiographic systems with 3D-2D registration techniques. While tibiofemoral kinematics are typically derived by tracking metallic implants, PF kinematic measurements are difficult as the patellar implant is radiotransparent and a representation of the resected patella bone requires either pre-surgical imaging and precise implant placement or post-surgical imaging. Statistical shape models (SSMs), used to characterize anatomic variation, provide an alternative means to obtain the representation of the resected patella for use in kinematic tracking. Using a virtual platform of a stereo-radiographic system, the objectives of this study were to evaluate the ability of an SSM to predict subject-specific 3D implanted patellar geometries from simulated 2D image profiles, and to formulate an effective data collection methodology for PF kinematics by considering accuracy for a variety of patient pose scenarios. An SSM of the patella was developed for 50 subjects and a leave-one-out approach compared SSM-predicted and actual geometries; average 3D errors were 0.45 ± 0.07 mm (mean ± standard deviation), which is comparable to the accuracy of traditional segmentation. Further, initial imaging of the patella in five unique stereo radiographic perspectives yielded the most accurate representation. The ability to predict the remaining patellar geometry of the implanted PF joint with radiographic images and SSM, instead of CT, can reduce radiation exposure and streamline in vivo kinematic evaluations.  相似文献   

20.
Combined knowledge of the functional kinematics and kinetics of the human body is critical for understanding a wide range of biomechanical processes including musculoskeletal adaptation, injury mechanics, and orthopaedic treatment outcome, but also for validation of musculoskeletal models. Until now, however, no datasets that include internal loading conditions (kinetics), synchronized with advanced kinematic analyses in multiple subjects have been available. Our goal was to provide such datasets and thereby foster a new understanding of how in vivo knee joint movement and contact forces are interlinked – and thereby impact biomechanical interpretation of any new knee replacement design. In this collaborative study, we have created unique kinematic and kinetic datasets of the lower limb musculoskeletal system for worldwide dissemination by assessing a unique cohort of 6 subjects with instrumented knee implants (Charité – Universitätsmedizin Berlin) synchronized with a moving fluoroscope (ETH Zürich) and other measurement techniques (including whole body kinematics, ground reaction forces, video data, and electromyography data) for multiple complete cycles of 5 activities of daily living. Maximal tibio-femoral joint contact forces during walking (mean peak 2.74 BW), sit-to-stand (2.73 BW), stand-to-sit (2.57 BW), squats (2.64 BW), stair descent (3.38 BW), and ramp descent (3.39 BW) were observed. Internal rotation of the tibia ranged from 3° external to 9.3° internal. The greatest range of anterio-posterior translation was measured during stair descent (medial 9.3 ± 1.0 mm, lateral 7.5 ± 1.6 mm), and the lowest during stand-to-sit (medial 4.5 ± 1.1 mm, lateral 3.7 ± 1.4 mm). The complete and comprehensive datasets will soon be made available online for public use in biomechanical and orthopaedic research and development.  相似文献   