首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
In this study we explore the hypothesis that estimates of failure loads in the thoracic spine by lumbar dual energy X-ray absorptiometry (DXA) are compromised of skeletal heterogeneity throughout the spine and artifacts of spinal DXA. We studied the correlation between mechanical failure loads of thoracic and lumbar vertebrae, and that of in situ vs. ex situ lumbar DXA with thoracic and lumbar fracture loads, respectively. One hundred and nineteen subjects (76 female, age 82+/-9yr; 43 male, age 77+/-11yr) were examined under in situ conditions (anterior-posterior direction), the scans being repeated ex situ (lateral projection) in 68 cases. The failure loads of thoracic vertebrae (T) 6 and 10, and lumbar vertebra (L) 3 were determined in axial compression, using a functional 3-segment unit. The correlation between thoracic failure loads (T6 vs. T10) was significantly (p<0.01) higher (r=0.85) than those between thoracic and lumbar vertebrae (r=0.68 and 0.61, respectively). Lateral ex situ DXA displayed a significantly higher correlation (p<0.05) with lumbar vertebral fracture loads than in situ anterior-posterior DXA (r=0.85 vs. 0.71), but the correlation of thoracic failure loads with lateral ex situ lumbar DXA was similar to that obtained in situ in anterior-posterior direction (r=0.69 vs. 0.69 for T10, and r=0.61 vs. 0.65 for T6). The correlation between fracture loads of different spinal segments, and between DXA and failure loads was not significantly different between men and women. The results demonstrate a substantial heterogeneity of mechanical competence throughout the spine in elderly individuals. Because of the high incidence of fractures in the thoracic spine, these findings suggest that, clinically, lateral DXA involves no relevant advantage over anterior-posterior measurements of the lumbar spine.  相似文献   

2.
Considerable differences in spinal morphology have been noted between humans and other hominoids. Although comparative analyses of the external morphology of vertebrae have been performed, much less is known regarding variations in internal morphology (density) and biomechanical performance among humans and closely related non-human primates. In the current study we utilize density calibrated computed tomography images of thoracic vertebral bodies from hominoids (n = 8-15 per species, human specimens 20-40 years of age) to obtain estimates of vertebral bone strength in axial compression and anteroposterior bending and to determine how estimates of strength scale with animal body mass. Our biomechanical analysis suggests that the strength of thoracic vertebral bodies is related to body mass (M) through power law relationships (y ∝ Mb) in which the exponent b is 0.89 (reduced major axis) for prediction of axial compressive strength and is equal to 1.89 (reduced major axis) for prediction of bending strength. No differences in the relationship between body mass and strength were observed among hominoids. However, thoracic vertebrae from humans were found to be disproportionately larger in terms of vertebral length (distance between cranial and caudal endplates) and overall vertebral body volume (p < 0.05). Additionally, vertebral bodies from humans were significantly less dense than in other hominoids (p < 0.05). We suggest that reduced density in human vertebral bodies is a result of a systemic increase in porosity of cancellous bone in humans, while increased vertebral body volume and length are a result of functional adaptation during growth resulting in a vertebral bone structure that is just as strong, relative to body mass, as in other hominoids.  相似文献   

3.
Due to the inherent limitations of DXA, assessment of the biomechanical properties of vertebral bodies relies increasingly on CT-based finite element (FE) models, but these often use simplistic material behaviour and/or single loading cases. In this study, we applied a novel constitutive law for bone elasticity, plasticity and damage to FE models created from coarsened pQCT images of human vertebrae, and compared vertebral stiffness, strength and damage accumulation for axial compression, anterior flexion and a combination of these two cases. FE axial stiffness and strength correlated with experiments and were linearly related to flexion properties. In all loading modes, damage localised preferentially in the trabecular compartment. Damage for the combined loading was higher than cumulated damage produced by individual compression and flexion. In conclusion, this FE method predicts stiffness and strength of vertebral bodies from CT images with clinical resolution and provides insight into damage accumulation in various loading modes.  相似文献   

4.
Determination of osteoporotic status is based primarily on areal bone mineral density (aBMD) obtained through dual X-ray absorptiometry (DXA). However, many fractures occur in patients with T-scores above the WHO threshold of osteoporosis, in part because DXA measures are insensitive to biomechanically important alterations in bone quality. The goal of this study was to determine--within groups of subjects with identical radius aBMD values--the extant variation in densitometric, geometric, microstructural, and biomechanical parameters. High resolution peripheral quantitative computed tomography (HR-pQCT) and DXA radius data from males and females spanning large ranges in age, osteoporotic status, and anthropometrics were compiled. 262 distal radius datasets were processed for this study. HR-pQCT scans were analyzed according to the manufacturer's standard clinical protocol to quantify densitometric, geometric, and microstructural indices. Micro-finite element analysis was performed to calculate biomechanical indices. Factor of risk of wrist fracture was calculated. Simulated aBMD calculated from HR-pQCT data was used to group scans for evaluation of variation in quantified indices. Indices reflecting the greatest variation within aBMD level were BMD in the central portion of the trabecular compartment (max CV 142), trabecular heterogeneity (max CV 90), and intra-cortical porosity (max CV 151). Of the biomechanical indices, cortical load fraction had the greatest variation (max CV 38). Substantial variations in indices reflecting density, structure, and biomechanical competence exist among subjects with identical aBMD levels. Overlap of these indices among osteoporotic status groups reflects the reported incidence of osteoporotic fracture in subjects classified as osteopenic or normal.  相似文献   

5.
Despite the pervasive occurrence of segmental morphologies in the animal kingdom, the study of segmental growth is almost entirely lacking, but may have significant implications for understanding the development of these organisms. We investigate the segmental and regional growth of the entire vertebral column of the rat (Rattus norvegicus) by fitting a Gompertz curve to length and age data for each vertebra and each vertebral region. Regional lengths are calculated by summing constituent vertebral lengths and intervertebral space lengths for cervical, thoracic, lumbar, sacral, and caudal regions. Gompertz curves allow for the estimation of parameters representing neonatal and adult vertebral and regional lengths, as well as initial growth rate and the rate of exponential growth decay. Findings demonstrate differences between neonatal and adult rats in terms of relative vertebral lengths, and differential growth rates between sequential vertebrae and vertebral regions. Specifically, relative differences in the length of vertebrae indicate increasing differences caudad. Vertebral length in neonates increases from the atlas to the middle of the thoracic series and decreases in length caudad, while adult vertebral lengths tend to increase caudad. There is also a general trend of increasing vertebral and regional initial growth and rate of growth decay caudad. Anteroposterior patterns of growth are sexually dimorphic, with males having longer vertebrae than females at any given age. Differences are more pronounced (a) increasingly caudad along the body axis, and (b) in adulthood than in neonates. Elucidated patterns of growth are influenced by a combination of developmental, functional, and genetic factors.  相似文献   

6.
Postnatal growth patterns within the vertebral column may be informative about body proportions and regionalization. We measured femur length, lengths of all pre‐sacral vertebrae, and lengths of intervertebral spaces, from radiographs of a series of 21 Eublepharis macularius, raised under standard conditions and covering most of the ontogenetic body size range. Vertebrae were grouped into cervical, sternal, and dorsal compartments, and lengths of adjacent pairs of vertebrae were summed before analysis. Femur length was included as an index of body size. Principal component analysis of the variance‐covariance matrix of these data was used to investigate scaling among them. PC1 explained 94.19% of total variance, interpreted as the variance due to body size. PC1 differed significantly from the hypothetical isometric vector, indicating overall allometry. The atlas and axis vertebrae displayed strong negative allometry; the remainder of the vertebral pairs exhibited weak negative allometry, isometry or positive allometry. PC1 explained a markedly smaller amount of variance for the vertebral pairs of the cervical compartment than for the remainder of the vertebral pairs, with the exception of the final pair. The relative standard deviations of the eigenvalues from the PCAs of the three vertebral compartments indicated that the vertebrae of the cervical compartment were less strongly integrated by scaling than were the sternal or dorsal vertebrae, which did not differ greatly between themselves in their strong integration, suggesting that the growth of the cervical vertebrae is constrained by the mechanical requirements of the head. Regionalization of the remainder of the vertebral column is less clearly defined but may be associated with wave form propagation incident upon locomotion, and by locomotory changes occasioned by tail autotomy and regeneration. Femur length exhibits negative allometry relative to individual vertebral pairs and to vertebral column length, suggesting a change in locomotor requirements over the ontogenetic size range.  相似文献   

7.
Vertebral compression fracture is a common medical problem in osteoporotic individuals. The quantitative computed tomography (QCT)-based finite element (FE) method may be used to predict vertebral strength in vivo, but needs to be validated with experimental tests. The aim of this study was to validate a nonlinear anatomy specific QCT-based FE model by using a novel testing setup. Thirty-seven human thoracolumbar vertebral bone slices were prepared by removing cortical endplates and posterior elements. The slices were scanned with QCT and the volumetric bone mineral density (vBMD) was computed with the standard clinical approach. A novel experimental setup was designed to induce a realistic failure in the vertebral slices in vitro. Rotation of the loading plate was allowed by means of a ball joint. To minimize device compliance, the specimen deformation was measured directly on the loading plate with three sensors. A nonlinear FE model was generated from the calibrated QCT images and computed vertebral stiffness and strength were compared to those measured during the experiments. In agreement with clinical observations, most of the vertebrae underwent an anterior wedge-shape fracture. As expected, the FE method predicted both stiffness and strength better than vBMD (R2 improved from 0.27 to 0.49 and from 0.34 to 0.79, respectively). Despite the lack of fitting parameters, the linear regression of the FE prediction for strength was close to the 1:1 relation (slope and intercept close to one (0.86 kN) and to zero (0.72 kN), respectively). In conclusion, a nonlinear FE model was successfully validated through a novel experimental technique for generating wedge-shape fractures in human thoracolumbar vertebrae.  相似文献   

8.
Our study was designed to examine the validity of dual energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) measurements as predictors of whole bone breaking strength in beagle femora. DXA was used to determine the bone mineral content, bone area, and 'areal' bone mineral density. PQCT was used to determine the cross-sectional moments of inertia, volumetric densities of the bone, and to calculate bone strength indices based on bone geometry and density. A three-point bending mechanical test was used to determine maximal load. Three variables from the pQCT data set explained 88% of the variance in maximal load, with the volumetric bone mineral density explaining 32% of the variance. The addition of the volumetric cortical density increased the adjusted r(2) to 0.601 (p=0.001) and the addition of an index created by multiplying volumetric cortical bone density by the maximum cross-sectional moment of inertia made further significant (p<0.001) improvements to an adjusted r(2) of 0.877. In comparison, when only the DXA variables were considered in a multiple regression model, areal bone mineral density was the only variable entered and explained only 51% (p<0.001) of the variance in maximal load. These results suggest that pQCT can better predict maximal load in whole beagle femora since pQCT provides information on the bone's architecture in addition to its volumetric density.  相似文献   

9.
Vertebral fractures associated with the loss of structural integrity of neoplastic vertebrae are common, and determined to the deterioration of the bone quality in the lesion area. The prediction of the fracture risk in metastatically involved spines can guide in deciding if preventive solutions, such as medical prophylaxis, bracing, or surgery are indicated for the patient. In this study, finite element models of 22 thoracolumbar vertebrae were built based on CT scans of three spines, covering a wide spectrum of possible clinical scenarios in terms of age, bone quality and degenerative features, taking into account the local material properties of bone tissue. Simulations were performed in order to investigate the effect of the size and location of the tumoral lesion, the bone quality and the vertebral level in determining the structural stability of the neoplastic vertebrae. Tumors with random size and positions were added to the models, for a total of 660 simulations in which a compressive load was simulated. Results highlighted the fundamental role of the tumor size, whereas the other parameters had a lower, but non-negligible impact on the axial collapse of the vertebra, the vertebral bulge in the transverse plane and the canal narrowing under the application of the load. All the considered parameters are radiologically measurable, and can therefore be translated in a straightforward way to the clinical practice to support decisions about preventive treatment of metastatic fractures.  相似文献   

10.
The current study considers the osteological morphology of the giraffe (Giraffa camelopardalis) vertebral column, with emphasis on evaluating both the adaptive and constraining features compared with other ungulates as a heuristic example in understanding evolutionary processes. Vertebral columns of giraffes varying in age from calf to adult were studied in order to understand the potential evolutionary scenarios that might have led to the modern phenotype. Data from the giraffe sample were then compared with the results from several other ungulate species, including the okapi and two species of camelids that also have visibly elongated necks. Our results show that the elongated neck of the modern giraffe appears to specifically result from evolutionary changes affecting the seven cervical vertebrae, independent of the remainder of the vertebral column. The cervical vertebrae comprise over half of the length of the total vertebral column in the giraffe. The increases in cervical vertebrae lengths also appear to be allometrically constrained, with alterations in the overall length of the neck resulting from the elongation of the entire cervical series, rather than from a single vertebra or subset of vertebrae. We place our results in the context of hypotheses concerning the origin and evolution of the giraffe neck, and the evolution of long necks in a broader sense. © 2009 The Linnean Society of London, Zoological Journal of the Linnean Society, 2009, 155 , 736–757.  相似文献   

11.
In primates, tail length is subject to wide variation, and the tail may even be absent. Tail length varies greatly between each species group of the genus Macaca, which is explained by climatic factors and/or phylogeographic history. Here, tail length variability was studied in hybrids of the Japanese (M. fuscata) and Taiwanese (Macaca cyclopis) macaque, with various degrees of hybridization being evaluated through autosomal allele typing. Relative tail length (percent of crown–rump length) correlated well with the number of caudal vertebrae. Length profiles of caudal vertebrae of hybrids and parent species revealed a common pattern: the length of several proximal-most vertebrae do not differ greatly; then from the third or fourth vertebra, the length rapidly increases and peaks at around the fifth to seventh vertebra; then the length plateaus for several vertebrae and finally shows a gentle decrease. As the number of caudal vertebrae and relative tail length increase, peak vertebral length and lengths of proximal vertebrae also increase, except that of the first vertebra, which only shows a slight increase. Peak vertebral length and the number of caudal vertebrae explained 92?% of the variance in the relative tail length of hybrids. Relative tail length correlated considerably well with the degree of hybridization, with no significant deviation from the regression line being observed. Thus, neither significant heterosis nor hybrid depression occurred.  相似文献   

12.
Vertebral bodies of teleost fish are formed by the sclerotomal bone covering the chordacentrum. The internal part of the sclerotomal bone is composed of an amphicoelous hourglass shaped autocentrum, which is common in most fish species. In contrast, the external shape of the sclerotomal bone varies extensively among species. There are multiple hypotheses regarding the composition and formation of the external structure. However, as they are based on studies of few extant or extinct species, their applicability to other species remains to be clarified. To understand the morphology, formation, and composition of vertebral bodies in teleosts, we performed a comparative analysis using micro-CT scans of 32 species from 10 orders of Teleostei and investigated the detailed morphology of the sclerotomal bone, especially its plate-like ridge and trabeculae. We discovered two structural characteristics that are shared among most of the examined species. One was the sheet-like trabeculae that extend radially from the center of the vertebral body with a constant thickness. The other was the presence of hollow spaces on the internal parts of the lateral ridge and trabeculae. The combination of different arrangements of sheet-like trabeculae and internal hollow spaces formed different shapes of the lateral structure of the vertebral body. The properties of these two characteristics suggest that the external part of the sclerotomal bone grows outward by deposition at the bone tip, and that, concurrently, bone absorption occurs in the internal part of the sclerotomal bone. The vertebral arches were also formed by the sheet-like trabeculae, indicating that both, the vertebral body and the arches, are formed by the same component. The micro-CT scanning data were uploaded to a public database so they can be used for future studies on fish vertebrae.  相似文献   

13.
This study investigated the numerical convergence characteristics of specimen-specific "voxel-based" finite element models of 14 excised human cadaveric lumbar vertebral bodies (age: 37-87; M = 6, F = 8) that were generated automatically from clinical-type CT scans. With eventual clinical applications in mind, the ability of the model stiffness to predict the experimentally measured compressive fracture strength of the vertebral bodies was also assessed. The stiffness of "low"-resolution models (3 x 3 x 3 mm element size) was on average only 4% greater (p = 0.03) than for "high"-resolution models (1 x 1 x 1.5 mm) despite interspecimen variations that varied over four-fold. Damage predictions using low- vs high-resolution models were significantly different (p = 0.01) at loads corresponding to an overall strain of 0.5%. Both the high (r2 = 0.94) and low (r2 = 0.92) resolution model stiffness values were highly correlated with the experimentally measured ultimate strength values. Because vertebral stiffness variations in the population are much greater than those that arise from differences in voxel size, these results indicate that imaging resolution is not critical in cross-sectional studies of this parameter. However, longitudinal studies that seek to track more subtle changes in stiffness over time should account for the small but highly significant effects of voxel size. These results also demonstrate that an automated voxel-based finite element modeling technique may provide an excellent noninvasive assessment of vertebral strength.  相似文献   

14.
In growing children, lumbar and femoral areal bone mineral density (aBMD), as measured by dual-energy X-ray absorptiometry (DXA), is influenced by skeletal growth and bone size. Correction of lumbar bone mineral density (BMD) for bone volume (volumetric BMD [vBMD]), by the use of mathematical extrapolations, reduces the confounding effect of bone size, but vBMD remains dependent on age and bone size during growth. Femoral (neck and mid-shaft) vBMD, assessed by DXA, is independent of age prior to puberty, but a slight increase occurs in late puberty and after menarche. Femoral (mid-shaft) cortical bone density and radial cortical and trabecular bone densities, assessed by quantitative computed tomography (QCT), show no peak during childhood or adolescence. Bone strength index, calculated by peripheral QCT, increases with age and correlates with handgrip strength, bone cross-sectional area and cortical area. Puberty is one of the main factors that influences lumbar bone mineral content and aBMD accumulation, but a high incidence of fractures occurs during this period of life, which may be associated with a reduced aBMD.  相似文献   

15.
Quantitative computer tomography (QCT)-based finite element (FE) models of vertebral body provide better prediction of vertebral strength than dual energy X-ray absorptiometry. However, most models were validated against compression of vertebral bodies with endplates embedded in polymethylmethalcrylate (PMMA). Yet, loading being as important as bone density, the absence of intervertebral disc (IVD) affects the strength. Accordingly, the aim was to assess the strength predictions of the classic FE models (vertebral body embedded) against the in vitro and in silico strengths of vertebral bodies loaded via IVDs. High resolution peripheral QCT (HR-pQCT) were performed on 13 segments (T11/T12/L1). T11 and L1 were augmented with PMMA and the samples were tested under a 4° wedge compression until failure of T12. Specimen-specific model was generated for each T12 from the HR-pQCT data. Two FE sets were created: FE-PMMA refers to the classical vertebral body embedded model under axial compression; FE-IVD to their loading via hyperelastic IVD model under the wedge compression as conducted experimentally. Results showed that FE-PMMA models overestimated the experimental strength and their strength prediction was satisfactory considering the different experimental set-up. On the other hand, the FE-IVD models did not prove significantly better (Exp/FE-PMMA: R²=0.68; Exp/FE-IVD: R²=0.71, p=0.84). In conclusion, FE-PMMA correlates well with in vitro strength of human vertebral bodies loaded via real IVDs and FE-IVD with hyperelastic IVDs do not significantly improve this correlation. Therefore, it seems not worth adding the IVDs to vertebral body models until fully validated patient-specific IVD models become available.  相似文献   

16.
目的:研究去势手术建立骨质疏松兔模型中松质骨微观结构和微观成分的时间序贯性变化。方法:40只新西兰白兔随机分为假手术组(sham组,n=20)和骨质疏松组(OP组,n=20)。OP组兔子给予去势手术处理,sham组给予假手术处理。分别于术后的0周、4周、6周、8周,利用DXA测量腰椎骨密度(每组每个时间点选择5只动物)。之后处死动物,采集腰椎标本。利用Micro-CT、FTIR、腰椎轴向压缩试验得到松质骨的微观结构、微观成分(骨矿盐晶体和胶原)和宏观力学参数。利用t检验比较同一时间点两组之间的相关参数。结果:OP组BMD逐渐下降,松质骨微观结构逐渐疏松,微观组成属性逐渐改变,宏观力学强度均逐渐下降。FTIR在4周时即检测到OP组腰椎骨矿盐和胶原基质比(P=0.046)、骨矿盐结晶度(P=0.018)、胶原交联比(P=0.006)发生显著性改变,早于BMD和微观结构的变化。OP组腰椎宏观生物力学强度在第8周时达到最低点(P=0.001)。结论:去势手术后,腰椎松质骨骨矿盐晶体和胶原属性最早发生变化,松质骨微观成分和微观结构的改变是导致椎体强度明显改变的原因。FTIR技术可以较早的检测到骨质疏松发生过程中骨组织微观成分的改变。  相似文献   

17.
Dual energy X-ray absorptiometry (DXA) is the standard for assessing fragility fracture risk using areal bone mineral density (aBMD), but only explains 60–70% of the variation in bone strength. High-resolution peripheral quantitative computed tomography (HR-pQCT) provides 3D-measures of bone microarchitecture and volumetric bone mineral density (vBMD), but only at the wrist and ankle. Finite element (FE) models can estimate bone strength with 86–95% precision. The purpose of this study is to determine how well vBMD and FE bone strength at the wrist and ankle relate to fracture strength at the hip and spine, and to compare these relationships with DXA measured directly at those axial sites. Cadaveric samples (radius, tibia, femur and L4 vertebra) were compared within the same body. The radius and tibia specimens were assessed using HR-pQCT to determine vBMD and FE failure load. aBMD from DXA was measured at the femur and L4 vertebra. The femur and L4 vertebra specimens were biomechanically tested to determine failure load. aBMD measures of the axial skeletal sites strongly correlated with the biomechanical strength for the L4 vertebra (r = 0.77) and proximal femur (r = 0.89). The radius correlated significantly with biomechanical strength of the L4 vertebra for vBMD (r = 0.85) and FE-derived strength (r = 0.72), but not with femur strength. vBMD at the tibia correlated significantly with femoral biomechanical strength (r = 0.74) and FE-estimated strength (r = 0.83), and vertebral biomechanical strength for vBMD (r = 0.97) and FE-estimated strength (r = 0.91). The higher correlations at the tibia compared to radius are likely due to the tibia’s weight-bearing function.  相似文献   

18.
This study assessed mouse strain-related differences in vertebral biomechanics and histomorphometry in inbred mice strains shown to differ in bone mineral content (BMC) and areal density (BMD) (as measured by pDEXA). Lumbar vertebrae L3 to L5 were collected from three mice strains (C3H/HeJ[C3], C57BL/6J[B6], and DBA/2J[D2], n=12/strain, 4-month-old female, 22.2 +/- 0.3g). BMC and BMD were measured in L3 and L4 using peripheral dual energy x-ray absorptiometry. The L4 vertebral body was then mechanically tested in compression to determine structural properties (ultimate/yield load, stiffness) from load-displacement curves and derive apparent material properties (ultimate/yield stress, and modulus of elasticity). L5 was processed for histomorphometric evaluation. Vertebral BMC and BMD were greater in C3 than in B6 and D2 mice. Vertebral trabecular/cancellous bone volume was smaller in C3 than in D2 and B6 mice. Trabecular bone formation rates were greater in D2 than in B6 and C3 mice. Osteoid surface was smaller in C3 mice than in B6 and D2 mice. Differences in osteoclast and mineralizing surfaces were not detected among the three mouse strains. In addition, there were no significant differences in biomechanical properties between the three strains. Despite the greatest BMC and areal BMD in C3 mice, the lack of strain-related differences in vertebral body strength data suggests that the biomechanical properties may be affected by the bone distribution and/or complex combination of cortical and cancellous bone at this site.  相似文献   

19.
Key methodological assumptions regarding the degree of natural variability and influence of sample handling and storage of elasmobranch vertebral chemistry were assessed using laser‐ablation inductively coupled plasma mass spectrometry. Vertebral chemistry of juvenile blacktip sharks Carcharhinus limbatus was examined to identify whether differences existed among different regions of the vertebral column, between thoracic vertebrae of individual fish or within individual vertebrae. Additionally, the effects of bleach exposure and storage in ethanol on vertebral chemistry were compared. No significant variation in vertebral chemistry was found among different regions of the vertebral column or between thoracic vertebrae, but significant differences among transect locations within individual vertebrae were observed. The variation at all three levels appears comparable with published data on sagittal otoliths of bilaterally symmetrical teleost fishes. The experimental assessment of potential treatment effects indicated vertebral chemistry was not significantly affected by bleach or exposure to ethanol. Taken together, these results support the idea that vertebrae taken from the same region of the vertebral column can be treated as equivalent and at least certain elements remain robust to exposure to bleach and ethanol.  相似文献   

20.

Objective

Abdominal adiposity is an important risk factor for diabetes and cardiovascular disease in Indians. Dual energy X-ray absorptiometry (DXA) can be used to determine abdominal fat depots, being more accessible and less costly than gold standard measures such as magnetic resonance imaging (MRI). DXA has not been fully validated for use in South Asians. Here, we determined the accuracy of DXA for measurement of abdominal fat in an Indian population by comparison with MRI.

Design

146 males and females (age range 18–74, BMI range 15–46 kg/m2) from Hyderabad, India underwent whole body DXA scans on a Hologic Discovery A scanner, from which fat mass in two abdominal regions was calculated, from the L1 to L4 vertebrae (L1L4) and from the L2 to L4 vertebrae (L2L4). Abdominal MRI scans (axial T1-weighted spin echo images) were taken, from which adipose tissue volumes were calculated for the same regions.

Results

Intra-class correlation coefficients between DXA and MRI measures of abdominal fat were high (0.98 for both regions). Although at the level of the individual, differences between DXA and MRI could be large (95% of DXA measures were between 0.8 and 1.4 times MRI measures), at the sample level, DXA only slightly overestimated MRI measures of abdominal fat mass (mean difference in L1L4 region: 2% (95% CI:0%, 5%), mean difference in L2L4 region:4% (95% CI: 1%, 7%)). There was evidence of a proportional bias in the association between DXA and MRI (correlation between difference and mean −0.3), with overestimation by DXA greater in individuals with less abdominal fat (mean bias in leaner half of sample was 6% for L1L4 (95%CI: 2, 11%) and 7% for L2L4 (95% CI:3,12%).

Conclusions

DXA measures of abdominal fat are suitable for use in Indian populations and provide a good indication of abdominal adiposity at the population level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号