首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE--To assess the efficacy of a regional autologous blood donation programme. DESIGN--Clinical and laboratory data were collected and stored prospectively. Transfusion data were collected retrospectively from hospital blood bank records. SETTING--Northern Region Blood Transfusion Service and 14 hospitals within the Northern Regional Health Authority. SUBJECTS--505 patients referred for autologous blood donation before elective surgery. MAIN OUTCOME MEASURES--Patient eligibility, adverse events from donation, autologous blood units provided, and autologous and allogeneic blood units transfused within 10 days of operation. RESULTS--Of 505 patients referred, 354 donated at least one unit. 78 of 151 referred patients who did not donate were excluded at the autologous clinic, mostly because of anaemia or ischaemic heart disease. In 73 cases the patient, general practitioner, or hospital consultant decided against donation. 363 autologous procedures were undertaken. In 213 (59%) cases all requested units were provided. The most common reasons for incomplete provision were late referral or anaemia. Adverse events accompanied 24 of 928 donations (2.6%). Transfusion data were obtained for 357 of the 363 procedures. 281 donors were transfused; autologous blood only was given to 225, autologous and allogeneic blood was given to 52, and allogeneic blood only was given to four. 648 of 902 (72%) units of autologous blood were transfused. Complete provision of requested autologous units was followed by allogeneic transfusion in 12 of 208 procedures (5.8%). Incomplete provision was followed by allogeneic transfusion in 44 of 149 procedures (30%). CONCLUSIONS--This study shows the feasibility of a regional autologous transfusion programme. Autologous donors only infrequently received allogeneic transfusion. Patients should be appropriately selected and referred early.  相似文献   

2.
Several methods have been found to be successful in reducing the need for allogeneic transfusion among the patients undergoing total hip replacement. The purpose of this prospective study was to analyse the quality and evaluate the effect of postoperative autotransfusion on the need for allogeneic transfusion following total hip replacement. The prospective study was performed in two groups of patients undergoing total hip replacement. Before the operative procedure all patients in both groups predonated two doses of autologous blood. In GROUP 1. the system for postoperative collection and transfusion of shed blood was used. In GROUP 2. the patients underwent total hip replacement without blood salvage system. Standard suction collection sets were used postoperatively. In this group shed blood was not transfused to the patients. The samples of preoperative donated autologus blood, allogeneic blood and postoperative collected autologous blood were analysed for number of red cells, hemoglobin, hematocrit, platelets, white blood cells, values of potassium, sodium, free hemoglobin and acid base status. The postoperatively blood salvage significantly reduced the use of allogeneic transfusion among patients managed with total hip replacement (allogeneic transfusion received 12% patients in Group 1 and 80% patients in Group 2; p<0.001). The values of red blood cells are significantly lower in postoperative collected autotransfusion blood compared with preoperative collected autologous blood and allogeneic blood (p<0.001). The values of potassium and acid base status were in normal range in postoperatively collected autotransfusion blood. These values in preoperatively collected autologous blood and allogeneic blood were out of normal range; (p<0.001). In addition to reducing the risk of complications that are associated with allogeneic transfusion, postoperative blood salvage may offer benefits including reducing the need for allogeneic blood. Our study confirmed that postoperative collection and transfusion of drainaged blood is simple and safe method that significantly reduce the need for allogeneic transfusion in patients underwent total hip replacement. The blood collected and transfused postoperatively has lower values of red blood cells and normal values of potassium and acid base balance. The transfusion of this blood caused no complications in our patients.  相似文献   

3.
ObjectiveTo assess the effectiveness of two mechanical methods of blood conservation in reducing the need for allogeneic red blood cells or coagulation products during cardiac surgery.DesignRandomised controlled trial.SettingRegional cardiac centre in a teaching hospital in Southampton.Participants263 adults aged 18-80 years undergoing elective coronary artery bypass surgery entered the study, of whom 252 completed the trial. All patients received routine perioperative care. Patients were allocated to one of three treatment groups: intraoperative cell salvage, intraoperative cell salvage with acute perioperative normovolaemic haemodilution, or no mechanical blood conservation. There were 84 patients in each group.ResultsOf the patients in the intraoperative cell salvage group, 26 were given a transfusion of allogeneic blood, compared with 43 in the control group (odds ratio 0.43 (95% confidence interval 0.23 to 0.80)). The mean number of units of allogeneic blood transfused per patient in the intraoperative cell salvage group was 0.68 units (SD=1.55), compared with 1.07 (1.56) units in the control group. 32 of the patients in the intraoperative cell salvage group were given any blood product, compared with 47 in the control group (odds ratio 0.47 (0.25 to 0.89); P=0.019). Combining acute perioperative normovolaemic haemodilution with intraoperative cell salvage conferred no additional benefits.ConclusionsAn intraoperative cell salvage device should be used in elective coronary artery bypass grafting. Pharmacological strategies may achieve further reductions in blood transfusions. Yet further reductions in blood transfusions could be achieved if the lower safe limit of haemoglobin concentration in patients undergoing cardiac surgery were known.

What is already known on this topic

Patients undergoing elective coronary artery bypass surgery often need a blood transfusionRecent meta-analyses have shown that the mechanical blood conservation techniques of intraoperative cell salvage and acute perioperative normovolaemic haemodilution may reduce the need for transfusion, but flawed methods in trials mean that clear evidence in cardiac surgery is lacking

What this study adds

Intraoperative cell salvage significantly reduces the number of patients needing an allogeneic blood transfusionCombining acute perioperative normovolaemic haemodilution with intraoperative cell salvage does not confer any additional benefit  相似文献   

4.
Peripheral blood lymphocytes (PBL) from a patient with poorly differentiated lymphocyte lymphoma (PDLL), after stimulation for 7 days with X-irradiated allogeneic lymphocytes pooled from three or ten donors (poolx), were cytotoxic for autologous lymphoma cells. Some clones lytic for autologous lymphoma cells, that were derived from this patient's pool-stimulated cells, resembled cytotoxic T lymphocytes (CTL), while other clones resembled natural killer (NK)-like cells in that they also lysed NK-sensitive HLA-negative K562 cells. In a second patient with more advanced PDLL, PDL cultured with T-cell growth factor (which is produced following stimulation with mitogens or alloantigens) lysed autologous lymphoma cells. On the basis of these in vitro findings, we asked whether IV transfusions with X-irradiated allogeneic leukocytes would result in anti-lymphoma responses in vivo. Ten days after transfusions with X-irradiated leukocytes from four unrelated donors, the first patient's two previously palpable nodes were no longer palpable and he remained in complete clinical remission for 6 months. The second patient had a temporary partial remission with dramatic reduction in size of multiple cervical and axillary nodes within 2 weeks after receiving the leukocyte transfusions.  相似文献   

5.
Posterior spinal instrumentation and fusion surgery in school-aged children and adolescents is associated with the potential for massive intraoperative blood loss, which requires significant allogeneic blood transfusion. Until now, the intraoperative use of the cell saver has been extensively adopted; however, its efficacy and cost-effectiveness have not been well established. Therefore, the aim of this study is to determine the efficacy and cost-effectiveness of intraoperative cell saver use. This study was a single-center, retrospective study of 247 school-aged and adolescent patients who underwent posterior spinal instrumentation and fusion surgery between August 2007 and June 2013. A cell saver was used intraoperatively in 67 patients and was not used in 180 patients. Matched case-control pairs were selected using a propensity score to balance potential confounders in baseline characteristics. Allogeneic red blood cell (RBC) and plasma transfusions as well as blood transfusion costs were analyzed. The propensity score matching produced 60 matched pairs. Compared to the control group, the cell saver group had significantly fewer intraoperative allogeneic RBC transfusions (P = 0.012). However, when the combined postoperative and total perioperative periods were evaluated for the use of allogeneic RBC transfusion, no significant differences were observed between the two groups (P = 0.813 and P = 0.101, respectively). With regard to the total cost of perioperative transfusion of all blood products (RBC and plasma), costs for the control group were slightly lower than those of the cell saver group, but this variance did not reach statistical significance (P = 0.095). The use of the cell saver in posterior spinal instrumentation and fusion surgery in school-aged children and adolescents was able to decrease the amount of intraoperative allogeneic RBC transfusion but failed to decrease total perioperative allogeneic RBC transfusion. Moreover, the use of the cell saver was not cost-effective.  相似文献   

6.
7.

Background

The use of cell salvage and autologous blood transfusion has become an important method of blood conservation. So far, there are no clinical data about the performance of the continuous autotransfusion device CATSmart.

Methods

In total, 74 patients undergoing either cardiac or orthopedic surgery were included in this prospective, bicenter and observational technical evaluation to validate red cell separation process and washout quality of CATSmart. The target of red cell separation process was defined as a hematocrit value in the packed red cell unit of 55–75% and of washout quality of 80–100% removal ratio.

Results

Hematocrit values measured by CATSmart and laboratory analysis were 78.5% [71.3%; 84.0%] and 73.7% [67.5%; 75.5%], respectively. Removal ratios for platelets 94.7% [88.2%; 96.7%], free hemoglobin 89.3% [85.2%; 94.9%], albumin 97.9% [96.6%; 98.5%], heparin 99.9% [99.9%; 100.0%], and potassium 92.5% [90.8%; 95.0%] were within the target range while removal of white blood cells was slightly worse 72.4% [57.9%; 87.3%].

Conclusion

The new autotransfusion device enables sufficient red cell separation and washout quality.
  相似文献   

8.
We have recently observed that the HLA-DR match between recipients and transfusion donors influences the beneficial effect of blood transfusions on allograft survival. To examine the immunologic effects of one-HLA-DR-Ag-matched and completely DR-mismatched transfusions, transfusion-induced changes in cell-mediated lympholysis (CML) were investigated. Blood donor directed CTL activity was measured in vitro before and after blood transfusion in 56 candidates for organ transplantation who received planned HLA-typed blood. We report that blood donor-directed CTL activity increased substantially after a single transfusion mismatched with the recipient for two HLA-DR Ag (p less than 0.0001). A transfusion matched for one HLA-DR Ag did not enhance CTL activity. No correlation was found between CTL reactivity and sharing of HLA class I Ag. The present study supports our previous observation that matching for at least one HLA class II Ag (HLA-DR) between transfusion recipient and blood donor is required if immunization by blood transfusion is to be avoided. These data show that the presence or absence of "autologous" HLA-DR Ag on the leucocytes of the transfusion donor plays a decisive rol whether immunization or immune suppression will ensue.  相似文献   

9.
Blood transfusion is frequently used in tumor patients, However, allogeneic blood transfusion have been claimed to be associated with an increased risk of negative outcomes, including transfusion reactions, fever, virus transmission, and alloimmunization. Other risks of homologous transfusion specific to the tumor patients are the potential deleterious effects on the recurrence of tumor and indefinite overall survival. On the contrary, autologous blood transfusion offers survival advantages to tumor patients and has been shown to minimize the occurrence of many detrimental allogeneic blood associated effects and complications. It also reduces the volume of banked blood needed and improves the prognosis of patients. However, the quality of salvaged blood is still a matter of debate, because it may contain tumor cells which are associated with potential detrimental effects such as metastasis. So, an advanced technology is needed to remove such contaminants to make autologous blood transfusion safer.  相似文献   

10.
ABSTRACT: BACKGROUND: Total hip and knee arthroplasties are two of the most commonly performed procedures in orthopedic surgery. Different blood-saving measures (BSMs) are used to reduce the often-needed allogenic blood transfusions in these procedures. A recent large randomized controlled trial showed it is not cost effective to use the BSMs of erythropoietin and perioperative autologous blood salvage in elective primary hip and knee arthroplasties. Despite dissemination of these study results, medical professionals keep using these BSMs. To actually change practice, an implementation strategy is needed that is based on a good understanding of target groups and settings and the psychological constructs that predict behavior of medical professionals. However, detailed insight into these issuses is lacking. Therefore, this study aims to explore which groups of professionals should be targeted at which settings, as well as relevant barriers and facilitators that should be taken into acount in the strategy to implement evidence-based, cost-effective blood transfusion management and to de-implement BSMs. METHODS: The study consists of three phases. First, a questionnaire survey among all Dutch orthopedic hospital departments and independent treatment centers (n?=?99) will be conducted to analyze current blood management practice. Second, semistructured interviews will be held among 10 orthopedic surgeons and 10 anesthesiologists to identify barriers and facilitators that are relevant for the uptake of cost-effective blood transfusion management. Interview questions will be based on the Theoretical Domains Interview framework. The interviews will be followed by a questionnaire survey among 800 medical professionals in orthopedics and anesthesiology (400 professionals per discipline) in which the identified barriers and facilitators will be ranked by frequency and importance. Finally, an implementation strategy will be developed based on the results from the previous phases, using principles of intervention mapping and an expert panel. DISCUSSION: The developed strategy for cost-effective blood transfusion management by de-implementing BSMs is likely to reduce costs for elective hip and knee arthroplasties. In addition, this study will lead to generalized knowledge regarding relevant factors for the de-implementation of non-cost-effective interventions and insight in the differences between implementation and de-implementation strategies.  相似文献   

11.
摘要 目的:研究贮存式自体成分输血对胃肠肿瘤根治术患者T淋巴细胞亚群、血液流变学以及预后的影响。方法:选取2016年12月~2017年12月我院收治的95例行胃肠肿瘤根治术的胃肠肿瘤早期患者作为研究对象。按随机数表法分为A组(n=47,贮存式自体成分输血)和B组(n=48,异体成分输血)。比较两组患者血常规指标[红细胞计数(RBC)、血红蛋白(Hb)、血细胞比容(Hct)]、免疫功能指标(CD3+、CD4+、CD8+、CD4+/CD8+)、血液流变学指标[红细胞沉降率、平均血液黏度、红细胞刚性指数及红细胞变形指数]的变化。随访患者2年,采用Kaplan-Meier曲线分析两组预后情况。结果:术前至术后7 d 时间段A组的CD3+、CD4+水平及CD4+/CD8+呈先降低后升高趋势,且术后7 d已恢复至术前水平;B组术后1 d、3 d、7 d的CD3+、CD4+水平及CD4+/CD8+明显低于A组(P<0.05),两组CD8+水平相比无差异(P>0.05) 。两组术后7 d的RBC、Hct、Hb分别较输血前下降(P<0.05),但两组间比较差异无统计学意义(P>0.05);两组患者术后7 d的红细胞沉降率均升高,但A组低于B组(P<0.05) ,两组患者术后的红细胞变形指数、平均血液黏度和红细胞刚性指数比较无差异 (P>0.05) 。Kaplan-Meier检验结果显示,A组较B组生存率明显升高(P<0.05)。结论:贮存式自体成分输血对胃肠肿瘤根治术患者红细胞沉降率、细胞免疫功能的影响程度较异体成分输血减轻,且贮存式自体成分输血可以明显提高患者的术后生存率。  相似文献   

12.
Burkina Faso is a continental West African country of approximately 16 M people whose transfusion needs were covered by 66,210 blood units collected mostly in 4 regional transfusion centers part of a national network but also from hospital-based smaller blood centers. The first group of blood centers relies almost exclusively on volunteer, non-remunerated, blood donors and only approximately 32.7% of them are repeating donation. In contrast, hospital-based blood centers rely nearly exclusively on family/replacement donors. The general strategy of the national blood transfusion network was to base the system exclusively on volunteer donors, which was nearly accomplished overall and completely at Bobo-Dioulasso, the largest center. However, despite considerable increase in blood collection, the overall blood supply remains low (4.7 units/1000 inhabitants) and worsens during the secondary school recesses since young student blood constitutes the most part of volunteer donors. To overcome such shortages, mobile blood collection sessions are organized in alternate sites such as military barracks or places of worship but with limited success. Another critical issue is that despite considerable efforts and help from community advocates, only 32.7% of volunteers repeat donation limiting the considerably safety advantage of a pool of regular donors.  相似文献   

13.

Purpose

Spine surgery, particularly reconstructive surgery, can be associated with significant blood loss, and blood transfusion. Antifibrinolytic agents are used routinely to reduce bleeding in cardiac, orthopaedic, and hepatic surgery. The purpose of this study was to assess the efficacy and safety of using antifibrinolytic agents in reducing blood loss and blood transfusions in spine surgery.

Methods

A systematic search of all related studies written in English published by October 2012 was conducted using the MEDLINE, EMBASE and the Cochrane Library databases. Randomized controlled trials that reported the drug dosage, total blood loss, blood transfusion and incidence of deep vein thrombosis as the primary outcome were included.

Results

Nine studies involving 482 patients were identified. Patients receiving antifibrinolytic agents had reduced blood loss (WMD =-288.8, 95 % CI – 46.49, - 110.19; P = 0.002), reduced blood transfusion (WMD =-242.7, 95 % CI – 422.57, - 62.95; P = 0.008), reduced blood transfusion rate (RR 0.73, 95% CI 0.58, 0.93; p = 0.010) and no increase (RR 0.25, 95 % CI 0.03, 2.22; P = 0.21) in the risk of deep vein thrombosis. Conclusions: We conclude that antifibrinolytic agents significantly decrease blood loss, blood transfusion, and there is no increase in the risk of deep vein thrombosisfor transfusion requirements in spine surgery.  相似文献   

14.
OBJECTIVE: To determine the cost, from a societal perspective, of blood transfusion in Canada. STUDY DESIGN: Cost-structure analysis. SETTING: Data were collected from eight hospitals and from six blood centres operated by the Canadian Red Cross Society in four provinces. OUTCOME MEASURES: Costs associated with four stages of transfusion-- collection, production, distribution and delivery--in 1933 were assessed. Costs were divided into the following categories; personnel, purchases, external services, overhead, donors'' time, patients'' time (for autologous transfusion), wastage and infection. RESULTS: The mean overall cost of a transfusion performed on an inpatient basis was $210 per unit of red blood cells for an allogeneic transfusion and $338 per unit of blood for an autologous transfusion. The mean cost of an allogeneic transfusion performed on an outpatient basis was $280 per unit of red blood cells. CONCLUSION: The costs determined in this study can be used in future studies comparing the cost-effectiveness of allogeneic transfusion with that of alternative methods.  相似文献   

15.
Problem A suspected high proportion of unnecessary blood transfusions occur in patients undergoing total joint replacement.Design Prospective before and after study evaluating the impact of a one page flow chart aimed at reducing the use of blood transfusions.Setting Orthopaedic tertiary care centre in Winterthur, Switzerland. 208 patients underwent primary total joint replacement of hips or knees during the control period (October 1998 to September 1999) and 217 during the intervention period (October 1999 to September 2000).Key measures for improvement Proportion of patients receiving allogeneic blood transfusions.Strategies for change A simple one page flow chart, which summarised graphically the perioperative decision pathways for anaemic patients, was placed in all charts of patients undergoing total joint replacement and handed out to medical staff from 4 October 1999 onwards. The implementation of the flow chart focused on its endorsement by chief physicians and the development of a sense of “ownership” among physicians and nurses.Effects of change The proportion of patients receiving allogeneic blood decreased from 35.0% to 19.8% (absolute difference -15.2%, 95% confidence interval -23.3 to -7.0%). The percentage of patients donating and receiving autologous blood also decreased. This led to overall savings of about £23 000 ($42 470; €34 441) (£103.50 per patient undergoing total joint replacement). Differences became more pronounced after adjustment for confounding factors.Lessons learnt Allogeneic blood transfusions in primary hip and knee replacement surgery may be reduced cost effectively by implementing a one page flow chart. Five key elements may have contributed: simplicity; wide distribution; no requirement for major changes; endorsement by local opinion leaders; and development of a sense of ownership. These elements may be used in other contexts to achieve sustained change of clinical practice.  相似文献   

16.
David M. Shaw 《Bioethics》2017,31(6):424-431
In this article I argue that vagueness concerning consent to post‐mortem organ donation causes considerable harm in several ways. First, the information provided to most people registering as organ donors is very vague in terms of what is actually involved in donation. Second, the vagueness regarding consent to donation increases the distress of families of patients who are potential organ donors, both during and following the discussion about donation. Third, vagueness also increases the chances that the patient's intention to donate will not be fulfilled due to the family's distress. Fourth, the consequent reduction in the number of donated organs leads to avoidable deaths and increased suffering among potential recipients, and distresses them and their families. There are three strategies which could be used to reduce the harmful effects of this vagueness. First, recategorizing the reasons (commonly referred to as ‘overrules’ under the current system) given by families who refuse donation from registered donors would bring greater clarity to donation discussions. Second, people who wish to donate their organs should be encouraged to discuss their wishes in detail with their families, and to consider recording their wishes in other ways. Finally, the consent system for organ donation could be made more detailed, ensuring both that more information is provided to potential donors and that they have more flexibility in how their intentions are indicated; this last strategy, however, could have the disadvantage of discouraging some potential donors from registering.  相似文献   

17.
BACKGROUND: Hypotensive epidural anaesthesia (HEA) combines a high epidural anaesthesia, performing a sympathetic blockade, with low-dose iv-infusion of epinephrine to stabilize circulation in the conscious patient. Mean artery blood pressure is reduced to 45-50 mmHg and hereby a reduced blood loss. In this study we have combined HEA with preoperative acute normovolaemic hemodilution (ANH) in attempt to further reduce the blood loss and need for blood transfusion in total knee arthroplasty surgery (TKR). METHODS: Twenty-eight patients scheduled for TKR are randomised to ANH or no hemodilution (non-ANH). Both groups are anaesthetized with HEA. ANH is established with predonation of 20 % of the total blood volume, and replacement with equal volume of HAES 6 %. Blood re-transfusion is completed within 6 h. RESULTS: A mean of 877 ml blood was predonated (19.7 % of the total blood volume). Blood loss was, except from the intraoperative loss, significantly higher in ANH group. The total loss was 1306 mL (ANH) vs. 1026 mL (non-ANH), p < 0.05. Except from the first hour postoperatively, hematocrit was identical in between groups postoperatively. The amount of blood transfusion was identical 386 ml (ANH) vs. 343 ml (non-ANH) (ns). 50 % went through surgery without receiving blood (ANH) vs. 58 % (non-ANH). No renal, neurological or cardiopulmonary complications were registered. CONCLUSIONS: These data suggest no benefits in combining HEA and ANH in TKR surgery. Probably because of the reduced viscosity of the blood after ANH, there is an increased postoperative blood loss. The need for homologous blood transfusion was identical.  相似文献   

18.
Transfusion of blood and blood products range from 2 to 8% of the cases of AIDS. The identification of HIV viral agent and the appearance of tests designed to detect antibodies associated with mechanisms of autologous transfusions and inactivation of virus of clotting factors concentrates have contributed to decrease this mean of transmission. Some aspects such as the difference of sensitivity in the tests, immunologic windows, and the appearance of new viruses such as the HIV 2 increase the complexity of the problem. Therefore, the services of hemotherapy all over the world must be aware of mechanisms of exclusion of potentially infected donors, in addition to education, and, mainly, the development of new techniques that can guarantee transfusion safety.  相似文献   

19.
The transfusion laboratories of 32 cardiothoracic surgical centres for adults were surveyed to determine the donor blood requirement for open heart surgery in the United Kingdom. Details of the transfusion practice and the use of blood conservation techniques were sought from a representative senior cardiac anaesthetist at each centre. Suitable data were received from 24 transfusion laboratories (75%) and 29 anaesthetists (90%). The mean (SD) blood use was 5.07 (1.53) units per operation. Seven centres routinely transfused fresh frozen plasma to all patients postoperatively. Experience with autologous deposit (three centres), "cell separators" (four centres), and the reinfusion of shed mediastinal blood (four centres) was limited. Prebypass phlebotomy for postbypass reinfusion (14 centres) and the infusion of residual oxygenator blood (27 centres) were the conservation techniques most commonly applied. In only nine centres was a postoperative normovolaemic anaemia to a haemoglobin concentration of less than 100 g/l accepted. Applying blood conservation techniques more widely would help to maintain blood supplies and reduce morbidity and mortality related to transfusion.  相似文献   

20.
To investigate the usage of blood componentsfor cardiac surgery inthe First Hospital of Lanzhou University, data from January 2014 to December 2016 were collected for analysis, including the number of cardiac surgeries and blood transfusions. There were 1 589 males and 1 076 females, aged from 1 to 73 years, with an average age of (53.97 ± 11.33) years, in this study. The results showed that the rate of blood-free surgery in the hospital increased year by year,while the proportion of blood-used operation to total operations decreased every year. The ratio of plasma and platelets used in cardiac surgery decreased, while the cryoprecipitate ratio used in cardiac surgery increased. This study indicates that the transfusion medical level in cardiac surgery is improved continuously, and that the infusion of blood components has become more secure, efficient and rational.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号