首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The recently developed bio-barcode assay for the detection of nucleic acid and protein targets without PCR has been shown to be extraordinarily sensitive, showing high sensitivity for both nucleic acid and protein targets. Two types of particles are used in the assay: (i) a magnetic microparticle with recognition elements for the target of interest; and (ii) a gold nanoparticle (Au-NP) with a second recognition agent (which can form a sandwich around the target in conjunction with the magnetic particle) and hundreds of thiolated single-strand oligonucleotide barcodes. After reaction with the analyte, a magnetic field is used to localize and collect the sandwich structures, and a DTT solution at elevated temperature is used to release the barcode strands. The barcode strands can be identified on a microarray via scanometric detection or in situ if the barcodes carry with them a detectable marker. The recent modification to the original bio-barcode assay method, utilizing DTT, has streamlined and simplified probe preparation and greatly enhanced the quantitative capabilities of the assay. Here we report the detailed methods for performing the ligand exchange bio-barcode assay for both nucleic acid and protein detection. In total, reagent synthesis, probe preparation and detection require 4 d.  相似文献   

2.
The recently developed bio-barcode (BBC) assay using polymerase chain reaction (PCR) to generate signals has been shown to be an extraordinarily sensitive method to detect protein targets. The BBC assay involves a magnetic microparticle (with antibody to capture the target of interest) and gold nanoparticle (with recognition antibody and thiolated single-stranded barcode DNAs) to form a sandwich around the target. The concentration of target is determined by the amount of barcode DNA released from the nanoparticles. Here we describe a modification using aptamers to substitute the gold nanoparticles for the BBC assay. In this study, we isolated a 76-mer monoclonal aptamer against cytochrome-c (cyto-c) and this single-stranded DNA in defined 3D structure for cyto-c was used in the BBC assay for both recognition and readout reporting. After magnetic separation, the aptamer was amplified by PCR and this aptamer-based barcode (ABC) assay was sensitive enough to detect the cyto-c in culture medium released from the apoptotic cells after drug treatment at the picomolar level. When compared to the conventional cyto-c detection by Western blot analysis, our ABC assay is sensitive, and time for the detection and quantification with ready-made probes was only 3 h.  相似文献   

3.
Nam JM  Jang KJ  Groves JT 《Nature protocols》2007,2(6):1438-1444
The colorimetric bio-barcode assay is a red-to-blue color change-based protein detection method with ultrahigh sensitivity. This assay is based on both the bio-barcode amplification method that allows for detecting miniscule amount of targets with attomolar sensitivity and gold nanoparticle-based colorimetric DNA detection method that allows for a simple and straightforward detection of biomolecules of interest (here we detect interleukin-2, an important biomarker (cytokine) for many immunodeficiency-related diseases and cancers). The protocol is composed of the following steps: (i) conjugation of target capture molecules and barcode DNA strands onto silica microparticles, (ii) target capture with probes, (iii) separation and release of barcode DNA strands from the separated probes, (iv) detection of released barcode DNA using DNA-modified gold nanoparticle probes and (v) red-to-blue color change analysis with a graphic software. Actual target detection and quantification steps with premade probes take approximately 3 h (whole protocol including probe preparations takes approximately 3 days).  相似文献   

4.
The present study describes an ultrasensitive protein biochip that employs nanogap electrodes and self-assembled nanoparticles to electrically detect protein. A bio-barcode DNA technique amplifies the concentration of target antigen at least 100-fold. This technique requires the establishment of conjugate magnetic nanoparticles (MNPs) and gold nanoparticles (AuNPs) through binding between monoclonal antibodies (2B2), the target antigen, and polyclonal antibodies (GP). Both GP and capture ssDNA (single-strand DNA) bonds to bio-barcode ssDNA are immobilized on the surface of AuNPs. A denature process releases the bio-barcode ssDNAs into the solution, and a hybridization process establishes multilayer AuNPs over the gap surface between electrodes. Electric current through double-layer self-assembled AuNPs is much greater than that through self-assembled monolayer AuNPs. This significant increase in electric current provides evidence that the solution contains the target antigen. Results show that the protein biochip attains a sensitivity of up to 1 pg/μL.  相似文献   

5.
In the present study, an electrochemical aptasensor for highly sensitive detection of thrombin was developed based on bio-barcode amplification assay. For this proposed aptasensor, capture DNA aptamerI was immobilized on the Au electrode. The functional Au nanoparticles (DNA–AuNPs) are loaded with barcode binding DNA and aptamerII. Through the specific recognition for thrombin, a sandwich format of Au/aptamerI/thrombin/DNA–AuNPs was fabricated. After hybridization with the PbSNPs-labeled barcode DNA, the assembled sensor was obtained. The concentration of thrombin was monitored based on the concentration of lead ions dissolved through differential pulse anodic stripping voltammetric (DPASV). Under optimum conditions, a detection limit of 6.2 × 10−15 mol L−1 (M) thrombin was achieved. In addition, the sensor exhibited excellent selectivity against other proteins.  相似文献   

6.
ABSTRACT: BACKGROUND: HIV-1 p24 antigen is a major viral component of human immunodeficiency virus type 1 (HIV-1) which can be used to identify persons in the early stage of infection and transmission of HIV-1 from infected mothers to infants. The detection of p24 is usually accomplished by using an enzyme-linked immunosorbent assay (ELISA) with low detection sensitivity. Here we report the use of two bio-barcode amplification (BCA) assays combined with polymerase chain reaction (PCR) and gel electrophoresis to quantify HIV-1 p24 antigen. METHOD: A pair of anti-p24 monoclonal antibodies (mAbs) were used in BCA assays to capture HIV-1 p24 antigen in a sandwich format and allowed for the quantitative measurement of captured p24 using PCR and gel electrophoresis. The first 1 G12 mAb was coated on microplate wells or magnetic microparticles (MMPs) to capture free p24 antigens. Captured p24 in turn captured 1D4 mAb coated gold nanoparticle probes (GNPs) containing double-stranded DNA oligonucleotides. One strand of the oligonucleotides was covalently immobilized whereas the unbound complimentary bio-barcode DNA strand could be released upon heating. The released bio-barcode DNA was amplified by PCR, electrophoresed in agarose gel and quantified. RESULTS: The in-house ELISA assay was found to quantify p24 antigen with a limit of detection (LOD) of 1,000 pg/ml and a linear range between 3,000 and 100,000 pg/ml. In contrast, the BCA-based microplate method yielded an LOD of 1 pg/ml and a linear detection range from 1 to 10,000 pg/ml. The BCA-based MMP method yielded an LOD of 0.1 pg/ml and a linear detection range from 0.1 to 1,000 pg/ml. CONCLUSIONS: When combined with PCR and simple gel electrophoresis, BCA-based microplate and MMPs assays can be used to quantify HIV-1 p24 antigen. These methods are 3--4 orders of magnitude more sensitive than our in-house ELISA-based assay and may provide a useful approach to detect p24 in patients newly infected with HIV.  相似文献   

7.
A robust duplex 5' nuclease (TaqMan) real-time PCR was developed and in-house validated for the specific detection of Salmonella enterica subspecies enterica serovar Enteritidis in whole chicken carcass rinses and consumption eggs. The assay uses specifically designed primers and a TaqMan probe to target the Prot6e gene located on the S. Enteritidis specific 60-kb virulence plasmid. As an internal amplification control to monitor Salmonella DNA in the sample, a second primer/TaqMan probe set detects simultaneously the Salmonella specific invA gene. The assay identified correctly 95% of the 79 Salmonella Enteritidis strains tested comprising 19 different phage types. None of the 119 non-Enteritidis strains comprising 54 serovars was positive for the Prot6e gene. The assay detection probability was for 10(2) or more genome equivalents 100% and for 10 equivalents 83%. A pre-PCR sample preparation protocol including a pre-enrichment step in buffered peptone water, followed by DNA extraction was applied on low levels of artificially contaminated whole chicken carcass rinses and eggs from hens as well as 25 potentially naturally contaminated chickens. The detection limit was less than three CFU per 50 ml carcass rinse or 10 ml egg. The sensitivity and specificity compared to the traditional culture-based detection method and serotyping were both 100%. Twenty-five potentially naturally contaminated chickens were compared by the real-time PCR and the traditional cultural isolation method resulting in four Salmonella positive samples of which two were positive for the Prot6e gene and serotyped as S. Enteritidis. We show also that Salmonella isolates which have a rough lipopolysaccharide structure could be assigned to the serovar Enteritidis by the real-time PCR. This methodology can contribute to meet the need of fast identification and detection methods for use in monitoring and control measures programmes.  相似文献   

8.
Oligonucleotide (ODN)-capped gold nanoparticles (Au-NPs) were used in a sandwich assay of ODN or polynucleotide by a flow injection surface plasmon resonance (SPR). A carboxylated dextran film was immobilized onto the SPR sensor surface to eliminate nonspecific adsorption of ODN-capped Au-NPs. The tandem use of signal amplification via the adlayer of the ODN-capped Au-NPs and the differential signal detection by the bicell detector on the SPR resulted in a remarkable DNA detection level. A 39-mer target at a quantity as low as 2.1 x 10(-20)mol, corresponding to 1.38 fM in a 15 microl solution, can be measured. To our knowledge, both the concentration and quantity detection levels are the lowest among all the gene analyses conducted with SPR to this point. The method is shown to be reproducible (relative standard deviation values <16%) and to possess high sequence specificity. It is also demonstrated to be viable for sequence-specific p53 cDNA analysis. The successful elimination of nonspecific adsorption of, and the signal amplification by, ODN-capped Au-NPs renders the SPR attractive for cases where the DNA concentration is extremely low and the sample availability is severely limited.  相似文献   

9.
生物条形码检测技术作为一种新的诊断工具,已逐渐应用于蛋白质、核酸和小分子物质的检测.生物条形码技术通过构建"纳米金颗粒-目标物-磁纳米颗粒"三明治结构,利用磁场作用,将结合在纳米金颗粒表面的大量相同序列的寡聚核苷酸洗脱下来,并进一步放大信号,实现对目标物的间接或直接检测.本文介绍了生物条形码检测技术的原理及其应用,综述...  相似文献   

10.
In this paper, we report a novel electrochemical detection approach for platelet-derived growth factor (PDGF) via "sandwich" structure and gold nanoparticles (Au-NPs) mediated amplification technique. The "sandwich" structure is fabricated based on the fact that PDGF has two aptamer-binding sites, which makes it possible for one PDGF molecule to connect with two aptamers simultaneously. It is found that this electrochemical system with "sandwich" structure and Au-NPs can significantly amplify the signal of electrochemical probe [Ru(NH(3))(5)Cl](2+) for PDGF detection, and thus increase the detection sensitivity significantly. As a result, this PDGF detection approach obtains an extraordinarily low detection limit of 1 x 10(-14)M for purified samples, 1 x 10(-12)M for contaminated-ridden samples or undiluted blood serum. This detection approach can also exhibit good stability and excellent specificity.  相似文献   

11.
通过扫描电子显微镜和Zeta电位仪对磁性纳米颗粒的形貌、粒径、表面电位等进行了表征。利用凝胶电泳阻滞试验分析磁性纳米颗粒与DNA的结合情况,研究磁性纳米颗粒对DNA的保护效果,运用MTT和流式细胞术分析磁性纳米颗粒对细胞的毒性。以绿色荧光蛋白基因为报告基因进行293T细胞的转染,研究磁性纳米颗粒与质粒DNA不同比例条件下对293T细胞的转染效率,并与脂质体(Lipofectamine2000)介导的转染进行比较分析。结果表明,磁性纳米颗粒与DNA可以稳定结合,可以保护DNA免受酶的消化作用,当磁性纳米颗粒与DNA比为1 1时,转染效率最高,优于脂质体(Lipotamine2000)介导的转染,且对细胞的毒害作用小于Lipotamine2000。  相似文献   

12.
Attomole (10(-18)mol) levels of RNA and DNA isolated from beer spoilage bacterial cells Lactobacillus brevis have been detected by the electrochemical sandwich DNA hybridization assay exploiting enzymatic activity of lipase. DNA sequences specific exclusively to L. brevis DNA and RNA were selected and used for probe and target DNA design. The assay employs magnetic beads (MB) modified with a capture DNA sequence and a reporter DNA probe labeled with the enzyme, both made to be highly specific for L. brevis DNA. Lipase-labeled DNAs captured on MBs in the sandwich assay were collected on gold electrodes modified with a ferrocene (Fc)-terminated SAM formed by aliphatic esters. Lipase hydrolysis of the ester bond released a fraction of the Fc redox active groups from the electrode surface, decreasing the electrochemical signal from the surface-confined Fc. The assay, shown to be efficient for analysis of short synthetic DNA sequences, was ineffective with genomic double stranded bacterial DNA, but it allowed down to 16 amole detection of 1563 nts long RNA, isolated from bacterial ribosomes without the need for PCR amplification, and single DNA strands produced from ribosomal RNA. No interference from E. coli RNA was registered. The assay allowed analysis of 400 L. brevis cells isolated from 1L of beer, which fits the "alarm signal" range (from 1 to 100 cells per 100mL).  相似文献   

13.
Here we have developed a novel nano-magnetic primer based electrochemiluminescence-polymerase chain reaction (NMPE-PCR) strategy for detection of genome. The key idea of this method is integrating the two in situ processes: PCR on the surface of magnetic nanoparticles (MNPs) and magnetic beads based ECL readout platform, to avoid some laborious manual operations and achieve rapid yet sensitive detection. At first, the approach employs a pair of functional primers for amplification: one is tris-(2,2'-bipyridyl) ruthenium (TBR) labeled primer; the other one is nano-magnetic primer which is prepared by attaching the primer to the surfaces of MNPs. With the presence of DNA analyte and PCR mixture, the TBR labeled products are directly loaded and enriched on the surface of MNPs during PCR cycling. Then the MNPs-TBR complexes can be analyzed by a magnetic ECL platform without any post-modification or post-incubation. Finally, we used Listeria monocytogenes as the target to examine these desirable properties of this assay, reaching a detection limit of 500 fg/μL for genome in 1 h. The proposed study has provided the evidence as a proof-of-concept, thus having potential for development of automatic mode for detection of specific gene.  相似文献   

14.
A sensitive and selective genomagnetic assay for the electrochemical detection of food pathogens based on in situ DNA amplification with magnetic primers has been designed. The performance of the genomagnetic assay was firstly demonstrated for a DNA synthetic target by its double-hybridization with both a digoxigenin probe and a biotinylated capture probe, and further binding to streptavidin-modified magnetic beads. The DNA sandwiched target bound on the magnetic beads is then separated by using a magneto electrode based on graphite-epoxy composite. The electrochemical detection is finally achieved by an enzyme marker, anti-digoxigenin horseradish peroxidase (HRP). The novel strategy was used for the rapid and sensitive detection of polymerase chain reaction (PCR) amplified samples. Promising resultants were also achieved for the DNA amplification directly performed on magnetic beads by using a novel magnetic primer, i.e., the up PCR primer bound to magnetic beads. Moreover, the magneto DNA biosensing assay was able to detect changes at single nucleotide polymorphism (SNP) level, when stringent hybridization conditions were used. The reliability of the assay was tested for Salmonella spp., the most important pathogen affecting food safety.  相似文献   

15.
A sensitive nonisotopic hybridization assay for HIV-1 DNA   总被引:8,自引:0,他引:8  
We have developed a microtiter-based sandwich hybridization assay for the detection of low copy number HIV-1 sequences. The assay employs a capture DNA sequence covalently coupled to microtiter wells through linker arms. The detection probe is a biotin-labeled DNA fragment derived from sequences adjacent to the capture sequence. After hybridization in the presence of sample nucleic acid, the detection probe remains bound only if the sample contained complementary sequences spanning the junction between capture and detection probes. The amount of detection probe bound is quantified by incubation with a peroxidase-streptavidin conjugate and a colorimetric peroxidase substrate. This assay has been combined with enzymatic target amplification to achieve sensitive detection of HIV-1 in patient samples. Following amplification of HIV-1 DNA using the polymerase chain reaction technique, a 190-bp product is produced. This product is easily and specifically quantified using the sandwich hybridization assay. The resulting test can detect one HIV-1-infected cell in 10(5) cells or about 30 molecules of HIV-1 DNA.  相似文献   

16.
Gold nanoparticles (Au-NPs) are usually used to amplify surface plasmon resonance (SPR) signals, however, the serious nonspecific adsorption has largely limited their practical applications. Here, we developed a novel Au-NPs enhanced biosensor without the effect of nonspecific adsorption: cutting Au-NPs off from the biosensor surface by RsaI endonuclease. In order to further improve the sensitivity, the probe DNA was designed specially. After the cleavage reaction, the residual probe DNA formed hairpin structure, which also resulted in a great change in SPR dip shift. Then, with the coaction of Au-NPs and conformation change of probe DNA, the SPR signal was amplified greatly. Using this method, we monitored the process of DNA cleavage in real-time and achieved a detection level of 5×10(-8) M. Moreover, the result of X-ray photoelectron spectroscopy (XPS) experiment further confirmed that large nonspecific adsorption existed. However, because SPR recorded a process in which the Au-NPs were cut off, the serious nonspecific adsorption did not affect the experimental result.  相似文献   

17.
The polymeric functionalization of superparamagnetic iron oxides nanoparticles is developed for cancer targeting capability and magnetic resonance imaging. Here the nanoparticles (NP) are decorated through the adsorption of a polymeric layer around the particle surface for the formation of core-shell. The synthesized magnetic nanoparticles (MNPs) are conjugated with fluorescent dye, targeting ligand, and drug molecules for improvement of target specific diagnostic and possible therapeutics applications. In this investigation doxorubicin was loaded into the shell of the MNPs and release study was carried out at different pH. The core-shell structure of magnetic NP coated chitosan matrix was visualized by TEM observation. The cytotoxicity of these magnetic NPs is investigated using MTT assay and receptor mediated internalization by HeLa and NIH3T3 cells are studied by fluorescence microscopy. Moreover, compared with T2-weighted magnetic resonance imaging (MRI) in the above cells, the synthesized nanoparticles are showed stronger contrast enhancements towards cancer cells.  相似文献   

18.
An ultra-sensitive sandwich ELISA was developed for detection of AFM1 in milk. The assay involved the immobilization of rat monoclonal antibody of AFM1 in 384 microtiter plate to capture AFM1 antigen. This was detected by tracer secondary rabbit poly-clonal antibody labelled with horseradish peroxidase upon addition of a luminol-based substrate. Milk samples with different fat percentage were analyzed after pre-treatment. Linear range of AFM1 detection 250-6.25 pg/mL was achieved in 3% fat milk. The miniaturised assay (10 μL) enabled ultra trace analysis of AFM1 in milk with much improved lower limit of detection at 0.005 pg/mL. A sensitive magnetic nanoparticles (MNPs) based ELISA was also developed and coupled with micro plate ELISA for analysis in milk. The hybrid-assay, by coupling the 1°Ab immobilized MNPs column with microwell plate assay enabled simultaneous measurement of low (0.5 pg/mL) and high AFM1 contamination (200 pg/mL). The most promising feature of this MNPs-ELISA is the small column size, high capture efficiency and lower cost over other reported materials. The proposed assay can be deployed for simultaneous analysis and monitoring of AFM1 in milk.  相似文献   

19.
AIMS: The purpose of this study was to apply nucleic acid sequence-based amplification (NASBA) for the detection of Salmonella enterica serovar Enteritidis (S. Enteritidis) in representative foods. METHODS AND RESULTS: A previously reported primer and probe set based on mRNA sequences of the dnaK gene of Salmonella were used in this study. To test for possible food matrix inhibition and assay detection limits, 25-g samples of representative food commodities (fresh meats, poultry, fish, ready-to-eat salads and bakery products) were pre-enriched with and without S. Enteritidis inoculation. The NucliSens(R) Basic Kit, supplemented with enzymes from various other commercial sources, was used for RNA isolation, NASBA amplification and electrochemiluminescent (ECL) detection. The end point detection limit of the NASBA-ECL assay was equivalent to 101 CFU of S. Enteritidis per amplification reaction. When the assay was tested on noncontaminated foods, none of the food matrices produced false-positive results. Some of the food matrices inhibited the NASBA-ECL reaction unless the associated RNA was diluted 10-fold prior to amplification. CONCLUSIONS: For all food items tested, positive ECL signals were achieved after 18 h of pre-enrichment and subsequent NASBA at initial inoculum levels of 102 and 101 CFU per 25 g food sample. SIGNIFICANCE AND IMPACT OF THE STUDY: This rapid, semi-automated detection method has potential for use in the food, agricultural and public health sectors.  相似文献   

20.
We report a sensitive method for visual detection of mercury ions (II) (Hg2?) in aqueous solution by using gold nanoparticles (Au-NPs) and thymine (T)-rich hairpin DNA probes. The thiolated hairpin DNA probe was immobilized on the Au-NP surface through a self-assembling method. Another thymine-rich, digoxin-labeled DNA probe was introduced to form DNA duplexes on the Au-NP surface with thymine-Hg2?-thymine (T-Hg2?-T) coordination in the presence of Hg2?. The Au-NPs associated with the formed duplexes were captured on the test zone of a lateral flow strip biocomponent (LFSB) by immunoreaction events between the digoxin on the duplexes and anti-digoxin antibodies on the LFSB. The accumulation of Au-NPs produced a characteristic red band on the test zone, enabling visual detection of Hg2? without instrumentation. A detection limit of 0.1 nM was obtained under optimal experimental conditions. This method provides a simple, rapid, sensitive approach for the detection of Hg2? and shows great promise for point-of-care and in-field detection of environmentally toxic mercury.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号