首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Formalin fixing with paraffin embedding (FFPE) has been a standard sample preparation method for decades, and archival FFPE samples are still very useful resources. Nonetheless, the use of FFPE samples in cancer genome analysis using next-generation sequencing, which is a powerful technique for the identification of genomic alterations at the nucleotide level, has been challenging due to poor DNA quality and artificial sequence alterations. In this study, we performed whole-exome sequencing of matched frozen samples and FFPE samples of tissues from 4 cancer patients and compared the next-generation sequencing data obtained from these samples. The major differences between data obtained from the 2 types of sample were the shorter insert size and artificial base alterations in the FFPE samples. A high proportion of short inserts in the FFPE samples resulted in overlapping paired reads, which could lead to overestimation of certain variants; >20% of the inserts in the FFPE samples were double sequenced. A large number of soft clipped reads was found in the sequencing data of the FFPE samples, and about 30% of total bases were soft clipped. The artificial base alterations, C>T and G>A, were observed in FFPE samples only, and the alteration rate ranged from 200 to 1,200 per 1M bases when sequencing errors were removed. Although high-confidence mutation calls in the FFPE samples were compatible to that in the frozen samples, caution should be exercised in terms of the artifacts, especially for low-confidence calls. Despite the clearly observed artifacts, archival FFPE samples can be a good resource for discovery or validation of biomarkers in cancer research based on whole-exome sequencing.  相似文献   

2.
To date the diagnosis of abdominal angiostrongyliasis (AA) depends on the histological identification of Angiostrongylus costaricensis (AC) in surgical specimens. However, microscopic evaluation is time consuming and often fails in identifying the parasite. We tested whether PCR might help in the diagnosis of AA by identifying parasite DNA in formalin-fixed paraffin-embedded (FFPE) tissue. We used primers based on DNA from Angiostrongilus cantonensis. Four groups of FFPE intestinal tissue were tested: (1) confirmed cases (n = 20), in which AC structures were present in the target tissue; (2) presumptive cases (n = 20), containing changes secondary to AC infection in the absence of AC structures; (3) negative controls (n = 3), consisting of normal colonic tissue; and (4) tissue affected by other parasitoses (n = 7), including strongyloidiasis, ascaridiasis, schistosomiasis, and enterobiasis. Most lesions of confirmed cases were located in small and/or large bowel (90%), as compared with presumptive cases, in which 70% of lesions were in appendix (P = 0.0002). When confronted with cases of other parasitoses, PCR showed sensitivity of 55%, specificity of 100% and positive predictive value of 100%. In presumptive cases PCR was positive in 4 (20%). All specimens from negative controls and other parasitoses were negative. In conclusion, the PCR technique showed intermediate sensitivity and optimal specificity, being clinically relevant when positive for abdominal angiostrongyliasis. It allowed a 20% gain in diagnosis of presumptive cases. PCR might help in the diagnosis of abdominal angiostrongyliasis, particularly when the pathologists are not experienced with such disease.  相似文献   

3.
Pneumocystis jirovecii is a common cause of life-threatening pneumonia among immunocompromised patients. Using 400 fresh bronchoalveolar lavage samples, we compared prospectively routine direct immunofluorescence assay (DFA) and a real-time PCR assay, performed on a LightCycler system, for the detection of P. jirovecii. Among the 66 PCR positive samples, 31 were positive by DFA. No patient was found as having the pattern "PCR--ve/DFA+ve". The semi-quantification of the P. jirovecii DNA was represented by the cycle threshold (Ct). Using DFA as the gold standard, the sensitivity of the PCR was 100% for Ct>/=28 and the specificity was 100% for Ct<22. Between these two points, the results could be discrepant. The patients of the "22/=28" group, and presented less frequently with HIV-infection and elevated lactate dehydrogenase (LDH) assay than in the "Ct<22" group. A negative PCR allowed us to exclude the P. jirovecii pneumonia. The real-time PCR assay seems to be an accurate diagnosis method and could replace the DFA. The semi-quantitative results should be helpful to distinguish colonized, subclinically infected and P. jirovecii pneumonia patients.  相似文献   

4.
5.
6.
We determined the best extraction buffer for proteomic investigation using formalin-fixation and paraffin-embedded (FFPE) specimens. A Zwittergent 3–16 based buffer, sodium dodecyl sulfate (SDS)-containing buffer with/without polyethylene glycol 20000 (PEG20000), urea-containing buffer, and FFPE-FASP protein preparation kit were compared for protein extraction from different types of rat FFPE tissues, including the heart, brain, liver, lung, and kidney. All of the samples were divided into two groups of laser microdissected (LMD) and non-LMD specimens. For both kinds of specimens, Zwittergent was the most efficient buffer for identifying peptides and proteins, was broadly applicable to different tissues without impairing the enzymatic digestion, and was well compatible with mass spectrometry analysis. As a high molecular weight carrier substance, PEG20000 improved the identification of peptides and proteins; however, such an advantage is limited to tissues containing submicrograms to micrograms of protein. Considering its low lytic strength, urea-containing buffer would not be the first alternative for protein recovery. In conclusion, Zwittergent 3–16 is an effective buffer for extracting proteins from FFPE specimens for downstream proteomics analysis.  相似文献   

7.
应用降落PCR和正交设计优化AtSUC9 PCR反应体系   总被引:1,自引:0,他引:1  
目的:建立最适的AtSUC9 PCR反应体系。方法:应用降落PCR和正交设计,从Mg2 、dNTPs、引物、甘油4种因素3个水平,对拟南芥AtSUC99 PCR反应体系进行优化。结果:确立了适合拟南芥AtSUC99 PCR反应体系:在20μl反应体系中,含模板1μg,引物(20μmol/L)0.5μl,dNTPs(10mmol/L)0.3μl,10×PCRbuffer2μl,Mg2 (25mmol/L)1.2μl,TaqDNAPolymerase1U,甘油10μl。结论:降落PCR和正交设计是一种有效的植物基因PCR体系优化方法。  相似文献   

8.

Background

Low biomass in the bacterial lung tissue microbiome utilizes quantitative PCR (qPCR) 16S bacterial assays at their limit of detection. New technology like droplet digital PCR (ddPCR) could allow for higher sensitivity and accuracy of quantification. These attributes are needed if specific bacteria within the bacterial lung tissue microbiome are to be evaluated as potential contributors to diseases such as chronic obstructive pulmonary disease (COPD). We hypothesize that ddPCR is better at quantifying the total bacterial load in lung tissue versus qPCR.

Methods

Control (n = 16) and COPD GOLD 2 (n = 16) tissue samples were obtained from patients who underwent lung resection surgery, were cut on a cryotome, and sections were assigned for use in quantitative histology or for DNA extraction. qPCR and ddPCR were performed on these samples using primers spanning the V2 region on the 16S rRNA gene along with negative controls. Total 16S counts were compared between the two methods. Both methods were assessed for correlations with quantitative histology measurements of the tissue.

Results

There was no difference in the average total 16S counts (P>0.05) between the two methods. However, the negative controls contained significantly lower counts in the ddPCR (0.55 ± 0.28 16S/uL) than in the qPCR assay (1.00 ± 0.70 16S copies) (P <0.05). The coefficient of variation was significantly lower for the ddPCR assay (0.18 ± 0.14) versus the qPCR assay (0.62 ± 0.29) (P<0.05).

Conclusion

Overall the ddPCR 16S assay performed better by reducing the background noise in 16S of the negative controls compared with 16S qPCR assay.  相似文献   

9.
We designed a single nucleotide primer extension (SNaPshot) assay for Pneumocystis jirovecii genotyping, targeting mt85 SNP of the mitochondrial large subunit ribosomal RNA locus, to improve minority allele detection. We then analyzed 133 consecutive bronchoalveolar lavage (BAL) fluids tested positive for P. jirovecii DNA by quantitative real‐time PCR, obtained from two hospitals in different locations (Hospital 1 [= 95] and Hospital 2 [= 38]). We detected three different alleles, either singly (mt85C: 39.1%; mt85T: 24.1%; mt85A: 9.8%) or together (27%), and an association between P. jirovecii mt85 genotype and the patient's place of hospitalization (= 0.011). The lowest fungal loads (median = 0.82 × 103 copies/μl; range: 15–11 × 103) were associated with mt85A and the highest (median = 1.4 × 106 copies/μl; range: 17 × 103–1.3 × 107) with mt85CTA (= 0.010). The ratios of the various alleles differed between the 36 mixed‐genotype samples. In tests of serial BALs (median: 20 d; range 4–525) from six patients with mixed genotypes, allele ratio changes were observed five times and genotype replacement once. Therefore, allele ratio changes seem more frequent than genotype replacement when using a SNaPshot assay more sensitive for detecting minority alleles than Sanger sequencing. Moreover, because microscopy detects only high fungal loads, the selection of microscopy‐positive samples may miss genotypes associated with low loads.  相似文献   

10.
基于数字PCR的单分子DNA定量技术研究进展   总被引:6,自引:0,他引:6  
数字PCR是一项针对单分子目标DNA的绝对定量技术.该技术是将含有DNA模板的反应溶液分配到大量独立的反应室中并且发生扩增反应,通过统计反应室中的阳性信号来定量DNA的拷贝数.DNA样品在反应室中随机和独立分布是单分子成功扩增和准确定量DNA拷贝数的关键因素.本文综述了数字PCR的发展历史、数字PCR与实时荧光定量PCR的区别,以及数字PCR在临床诊断、转基因成分定量、单细胞基因表达、环境微生物检测和下一代测序等方面的最新进展,并展望了该技术的应用前景.  相似文献   

11.
PCR detection methods are useful in studies of organisms not amenable to culture. Inhibitors in environmental samples can interfere with such assays. We describe a magnetic bead DNA capture protocol that removes inhibitors from outdoor air samples, maintaining the sensitivity of a 16S Pneumocystis carinii mitochondrial rRNA gene-based PCR.  相似文献   

12.
Current Fungal Infection Reports - The aim of this work is to contribute to the knowledge of diagnosis, burden, and mortality of pneumocystosis or Pneumocystis jirovecii pneumonia (PCP) in...  相似文献   

13.
Performance of immunofluorescence staining on archival formalin-fixed paraffin-embedded human tissues is generally not considered to be feasible, primarily due to problems with tissue quality and autofluorescence. We report the development and application of procedures that allowed for the study of a unique archive of thymus tissues derived from autopsies of individuals exposed to atomic bomb radiation in Hiroshima, Japan in 1945. Multiple independent treatments were used to minimize autofluorescence and maximize fluorescent antibody signals. Treatments with NH3/EtOH and Sudan Black B were particularly useful in decreasing autofluorescent moieties present in the tissue. Deconvolution microscopy was used to further enhance the signal-to-noise ratios. Together, these techniques provide high-quality single- and dual-color fluorescent images with low background and high contrast from paraffin blocks of thymus tissue that were prepared up to 60 years ago. The resulting high-quality images allow the application of a variety of image analyses to thymus tissues that previously were not accessible. Whereas the procedures presented remain to be tested for other tissue types and archival conditions, the approach described may facilitate greater utilization of older paraffin block archives for modern immunofluorescence studies.  相似文献   

14.
The purpose of this prospective study was to compare two different milk preparation methods to assay for the presence of Mycobacterium bovis by PCR. Detection by a C18-carboxypropylbetaine (CB-18)-based sample processing method was compared to extraction of DNA from milk with glass beads. Samples from 17 skin test-positive cattle were analyzed. Following CB-18 processing and glass bead extraction, the sensitivity of IS6110-based PCR was 94.1 and 58.8%, respectively (P < 0.025). Because CB-18 processing will permit the proficient use of PCR for diagnosis and surveillance of bovine tuberculosis, it will contribute to the more efficient detection and control of tuberculosis.  相似文献   

15.
Heat-induced epitope retrieval (HIER) is widely used for immunohistochemistry on formalin-fixed paraffin-embedded tissue and includes temperatures well above the melting point of paraffin. We therefore tested whether traditional xylene-based removal of paraffin is required on sections from paraffin-embedded tissue, when HIER is performed by vigorous boiling in 10 mM Tris/0.5 mM EGTA-buffer (pH=9). Immunohistochemical results using HIER with or without prior dewaxing in xylene were evaluated using 7 primary antibodies targeting proteins located in the cytosol, intracellular vesicles and plasma membrane. No effect of omitting prior dewaxing was observed on staining pattern. Semiquantitative analysis did not show HIER to influence the intensity of labelling consistently. Consequently, quantification of immune labelling intensity using fluorescent secondary antibodies was performed at 5 dilutions of primary antibody with and without prior dewaxing in xylene. No effect of omitting prior dewaxing on signal intensity was detectable indicating similar immunoreactivity in dewaxed and non-dewaxed sections. The intensity of staining the nucleus with the DNA-stain ToPro3 was similarly unaffected by omission of dewaxing in xylene.In conclusion, the HIER procedure described and tested can be used as a single procedure enabling dewaxing, hydration and epitope retrieval for immunohistochemistry in formalin-fixed paraffin-embedded tissue.Key words: Immunolabelling, antibodies, histology, protein localization, HIER  相似文献   

16.
17.
In this study, food samples were intentionally contaminated with Escherichia coli O157:H7, and then DNA was isolated by using four commercial kits. The isolated DNA samples were compared by using real-time PCR detection of the Shiga toxin genes. The four kits tested worked similarly.  相似文献   

18.
目的分析本地区耶氏孢子菌肺炎(Pneumocystis jirovecii pneumonia,PJP)患者的流行趋势、临床特征、血清学标志物,为PJP患者的早预防、早诊断提供理论依据。方法回顾性分析江西省3所综合性医院2016年1月至2019年12月诊断为PJP的49例住院患者,收集患者临床资料,包括基本信息、危险因素、临床表现、实验室结果、影像学报告、预后等。结果49例PJP患者绝大多数HIV阴性(89.8%),且以中年男性为主。AIDS、肾脏疾病(47.7%)和结缔组织疾病(29.6%)为PJP患者主要危险因素,临床表现以干咳(83.7%)、白色黏痰,发热(79.6%)为主,其次为呼吸困难。PJP患者以低剂量/短时间(<3个月)使用糖皮质激素或免疫抑制剂为特征。85%以上PJP患者实验室指标超过参考范围的有中性粒细胞百分比、C反应蛋白、氧分压、乳酸脱氢酶和涎液化糖链抗原-6(KL-6)。结论HIV阴性患者感染PJ逐渐增多,肾脏疾病和结缔组织疾病是其主要危险因素,LDH、BG和KL-6可作为PJP患者的重要辅助检查。  相似文献   

19.
Few data are available regarding the reliability of fluorescence in-situ hybridization (FISH), especially for chromosomal deletions, in high-throughput settings using tissue microarrays (TMAs). We performed a comprehensive FISH study for the detection of chromosomal translocations and deletions in formalin-fixed and paraffin-embedded (FFPE) tumor specimens arranged in TMA format. We analyzed 46 B-cell lymphoma (B-NHL) specimens with known karyotypes for translocations of IGH-, BCL2-, BCL6- and MYC-genes. Locus-specific DNA probes were used for the detection of deletions in chromosome bands 6q21 and 9p21 in 62 follicular lymphomas (FL) and six malignant mesothelioma (MM) samples, respectively. To test for aberrant signals generated by truncation of nuclei following sectioning of FFPE tissue samples, cell line dilutions with 9p21-deletions were embedded into paraffin blocks. The overall TMA hybridization efficiency was 94%. FISH results regarding translocations matched karyotyping data in 93%. As for chromosomal deletions, sectioning artefacts occurred in 17% to 25% of cells, suggesting that the proportion of cells showing deletions should exceed 25% to be reliably detectable. In conclusion, FISH represents a robust tool for the detection of structural as well as numerical aberrations in FFPE tissue samples in a TMA-based high-throughput setting, when rigorous cut-off values and appropriate controls are maintained, and, of note, was superior to quantitative PCR approaches.  相似文献   

20.
To obtain gene expression profiles from samples collected in clinical trials, we conducted a pilot study to assess feasibility and estimate sample attrition rates when profiling formalin-fixed, paraffin-embedded specimens. Ten matched fresh-frozen and fixed breast cancer samples were profiled using the Illumina HT-12 and Ref-8 chips, respectively. The profiles obtained with Ref 8, were neither technically nor biologically reliable since they failed to yield the expected separation between estrogen receptor positive and negative samples. With the use of Affymetrix HG-U133 2.0 Plus chips on fixed samples and a quantitative polymerase chain reaction -based sample pre-assessment step, results were satisfactory in terms of biological reliability, despite the low number of present calls (M = 21%±5). Compared with the Illumina DASL WG platform, Affymetrix data showed a wider interquartile range (1.32 vs 0.57, P<2.2 E-16,) and larger fold changes. The Affymetrix chips were used to run a pilot study on 60 fixed breast cancers. By including in the workflow the sample pre-assessment steps, 96% of the samples predicted to give good results (44/46), were in fact rated as satisfactory from the point of view of technical and biological meaningfulness. Our gene expression profiles showed strong agreement with immunohistochemistry data, were able to reproduce breast cancer molecular subtypes, and allowed the validation of an estrogen receptor status classifier derived in frozen samples. The approach is therefore suitable to profile formalin-fixed paraffin-embedded samples collected in clinical trials, provided that quality controls are run both before (sample pre-assessment) and after hybridization on the array.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号