首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Cardiovascular response to cycle exercise during and after pregnancy   总被引:1,自引:0,他引:1  
Our purpose was to determine if pregnancy alters the cardiovascular response to exercise. Thirty-nine women [29 +/- 4 (SD) yr], performed submaximal and maximal exercise cycle ergometry during pregnancy (antepartum, AP, 26 +/- 3 wk of gestation) and postpartum (PP, 8 +/- 2 wk). Neither maximal O2 uptake (VO2max) nor maximal heart rate (HR) was different AP and PP (VO2 = 1.91 +/- 0.32 and 1.83 +/- 0.31 l/min; HR = 182 +/- 8 and 184 +/- 7 beats/min, P greater than 0.05 for both). Cardiac output (Q, acetylene rebreathing technique) averaged 2.2 to 2.8 l/min higher AP (P less than 0.01) at rest and at each exercise work load. Increases in both HR and stroke volume (SV) contributed to the elevated Q at the lower exercise work loads, whereas an increased SV was primarily responsible for the higher Q at higher levels. The slope of the Q vs. VO2 relationship was not different AP and PP (6.15 +/- 1.32 and 6.18 +/- 1.34 l/min Q/l/min VO2, P greater than 0.05). In contrast, the arteriovenous O2 difference (a-vO2 difference) was lower at each exercise work load AP, suggesting that the higher Q AP was distributed to nonexercising vascular beds. We conclude that Q is greater and a-vO2 difference is less at all levels of exercise in pregnant subjects than in the same women postpartum but that the coupling of the increase in Q to the increase in systemic O2 demand (VO2) is not different.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
Foreign and soluble gas rebreathing methods are attractive for determining cardiac output (Q(c)) because they incur less risk than traditional invasive methods such as direct Fick and thermodilution. We compared simultaneously obtained Q(c) measurements during rest and exercise to assess the accuracy and precision of several rebreathing methods. Q(c) measurements were obtained during rest (supine and standing) and stationary cycling (submaximal and maximal) in 13 men and 1 woman (age: 24 +/- 7 yr; height: 178 +/- 5 cm; weight: 78 +/- 13 kg; Vo(2max): 45.1 +/- 9.4 ml.kg(-1).min(-1); mean +/- SD) using one-N(2)O, four-C(2)H(2), one-CO(2) (single-step) rebreathing technique, and two criterion methods (direct Fick and thermodilution). CO(2) rebreathing overestimated Q(c) compared with the criterion methods (supine: 8.1 +/- 2.0 vs. 6.4 +/- 1.6 and 7.2 +/- 1.2 l/min, respectively; maximal exercise: 27.0 +/- 6.0 vs. 24.0 +/- 3.9 and 23.3 +/- 3.8 l/min). C(2)H(2) and N(2)O rebreathing techniques tended to underestimate Q(c) (range: 6.6-7.3 l/min for supine rest; range: 16.0-19.1 l/min for maximal exercise). Bartlett's test indicated variance heterogeneity among the methods (P < 0.05), where CO(2) rebreathing consistently demonstrated larger variance. At rest, most means from the noninvasive techniques were +/-10% of direct Fick and thermodilution. During exercise, all methods fell outside the +/-10% range, except for CO(2) rebreathing. Thus the CO(2) rebreathing method was accurate over a wider range (rest through maximal exercise), but was less precise. We conclude that foreign gas rebreathing can provide reasonable Q(c) estimates with fewer repeat trials during resting conditions. During exercise, these methods remain precise but tend to underestimate Q(c). Single-step CO(2) rebreathing may be successfully employed over a wider range but with more measurements needed to overcome the larger variability.  相似文献   

3.
Maximal aerobic capacity (Vo(2max)) decreases progressively with age, primarily because of a reduction in maximal cardiac output (Q(max)). This age-associated decline in Vo(2max) may be partially mediated by the development of oxidative stress that can suppress beta-adrenergic-receptor responsiveness and, consequently, reduce Q(max). To test this hypothesis, Vo(2max) (indirect calorimetry) and Q(max) (open-circuit acetylene breathing) were determined in 12 young (23 +/- 1 yr, mean +/- SE) and 10 older (61 +/- 1 yr) adults following systemic infusion of either saline (control) and/or the powerful antioxidant ascorbic acid (acute: bolus 0.06; drip 0.02 g/kg fat-free mass) and following chronic 30-day oral administration of ascorbic acid (500 mg/day). Plasma ascorbic acid concentration was not different between young and older adults and was increased similarly, independent of age [change (Delta) acute = 1,055 +/- 117%; Delta chronic = 62 +/- 19%]. Oxidized low-density lipoprotein concentration was greater (P < 0.001) in older (57 +/- 5 U/l) compared with young (34 +/- 3 U/l) adults and was reduced in both groups (P < 0.02) following acute (Delta = -6 +/- 2%) but not chronic (P = 0.18) ascorbic acid administration. Control (baseline) Vo(2max) and Q(max) were positively related (r = 0.76, P < 0.001) and were lower (P < 0.05) in older (34 +/- 2 ml.kg(-1).min(-1); 16.1 +/- 1.1 l/min) compared with young (43 +/- 3 ml.kg(-1).min(-1); 20.2 +/- 0.9 l/min) adults. Following ascorbic acid administration, neither Vo(2max) (young acute = 41 +/- 2; young chronic = 42 +/- 2; older acute = 34 +/- 2; older chronic = 34 +/- 2 ml.kg(-1).min(-1)) nor Q(max) (young acute = 20.1 +/- 0.9; young chronic = 19.1 +/- 0.8; older acute = 16.2 +/- 1.1; older chronic = 16.6 +/- 1.4 l/min) was changed. These data suggest that ascorbic acid administration does not affect the age-associated reduction in Q(max) and Vo(2max).  相似文献   

4.
We tested the hypothesis that the work of the heart was not a limiting factor in the attainment of maximal oxygen uptake (VO2 max). We measured cardiac output (Q) and blood pressures (BP) during exercise at two different rates of maximal work to estimate the work of the heart through calculation of the rate-pressure product, as a part of the ongoing discussion regarding factors limiting VO2 max. Eight well-trained men (age 24.4 +/- 2.8 yr, weight 81.3 +/- 7.8 kg, and VO2 max 59.1 +/- 2.0 ml x min(-1) x kg(-1)) performed two maximal combined arm and leg exercises, differing 10% in watts, with average duration of time to exhaustion of 4 min 50 s and 3 min 40 s, respectively. There were no differences between work rates in measured VO2 max, maximal Q, and peak heart rate between work rates (0.02 l/min, 0.3 l/min, and 0.8 beats/min, respectively), but the systolic, diastolic, and calculated mean BP were significantly higher (19, 5, and 10 mmHg, respectively) in the higher than in the lower maximal work rate. The products of heart rate times systolic or mean BP and Q times systolic or mean BP were significantly higher (3,715, 1,780, 569, and 1,780, respectively) during the higher than the lower work rate. Differences in these four products indicate a higher mechanical work of the heart on higher than lower maximal work rate. Therefore, this study does not support the theory, which states that the work of the heart, and consequently VO2 max, during maximal exercise is hindered by a command from the central nervous system aiming at protecting the heart from being ischemic.  相似文献   

5.
The importance of cardiac output (CO) to blood pressure level during vasovagal syncope is unknown. We measured thermodilution CO, mean blood pressure (MBP), and leg muscle mean sympathetic nerve activity (MSNA) each minute during 60 degrees head-up tilt in 26 patients with recurrent syncope. Eight patients tolerated tilt (TT) for 45 min (mean age 60 +/- 5 yr) and 15 patients developed syncope during tilt (TS) (mean age 58 +/- 4 yr, mean tilt time 15.4 +/- 2 min). In TT patients, CO decreased during the first minute of tilt (from 3.2 +/- 0.2 to 2.5 +/- 0.3 l x min(-1) x m(-2), P = 0.001) and thereafter remained stable between 2.5 +/- 0.3 (P = 0.001) and 2.4 +/- 0.2 l x min(-1) x m(-2) (P = 0.004) at 5 and 45 min, respectively. In TS patients, CO decreased during the first minute (from 3.3 +/- 0.2 to 2.7 +/- 0.1 l x min(-1) x m(-2), P = 0.02) and was stable until 7 min before syncope, falling to 2.0 +/- 0.2 at syncope (P = 0.001). Regression slopes for CO versus time during tilt were -0.01 min(-1) in TT versus -0.1 l x min(-1) x m(-2) x min(-1) in TS (P = 0.001). However, MBP was more closely correlated to total peripheral resistance (R = 0.56, P = 0.001) and MSNA (R = 0.58, P = 0.001) than CO (R = 0.32, P = 0.001). In vasovagal reactions, a progressive decline in CO may contribute to hypotension some minutes before syncope occurs.  相似文献   

6.
We examined the effect of maternal weight gain during pregnancy on exercise performance. Ten women performed submaximal cycle (up to 60 W) and treadmill (4 km/h, up to 10% grade) exercise tests at 34 +/- 1.5 (SD) wk gestation and 7.6 +/- 1.7 wk postpartum. Postpartum subjects wearing weighted belts designed to equal their body weight during the antepartum tests performed two additional treadmill tests. Absolute O2 uptake (VO2) at the same work load was higher during pregnancy than postpartum during cycle (1.04 +/- 0.08 vs. 0.95 +/- 0.09 l/min, P = 0.014), treadmill (1.45 +/- 0.19 vs. 1.27 +/- 0.20 l/min, P = 0.0002), and weighted treadmill (1.45 +/ 0.19 vs. 1.36 +/- 0.20 l/min, P = 0.04) exercise. None of these differences remained, however, when VO2 was expressed per kilogram of body weight. Maximal VO2 (VO2max) estimated from the individual heart rate-VO2 curves was the same during and after pregnancy during cycling (1.96 +/- 0.37 to 1.98 +/- 0.39 l/min), whereas estimated VO2max increased postpartum during treadmill (2.04 +/- 0.38 to 2.21 +/- 0.36 l/min, P = 0.03) and weighted treadmill (2.04 +/- 0.38 to 2.19 +/- 0.38 l/min, P = 0.03) exercise. We conclude that increased body weight during pregnancy compared with the postpartum period accounts for 75% of the increased VO2 during submaximal weight-bearing exertion in pregnancy and contributes to reduced exercise capacity. The postpartum increase in estimated VO2max during weight-bearing exercise is the result of consistently higher antepartum heart rates during all submaximal work loads.  相似文献   

7.
We examined gender differences in growth hormone (GH) secretion during rest and exercise. Eighteen subjects (9 women and 9 men) were tested on two occasions each [resting condition (R) and exercise condition (Ex)]. Blood was sampled at 10-min intervals from 0600 to 1200 and was assayed for GH by chemiluminescence. At R, women had a 3.69-fold greater mean calculated mass of GH secreted per burst compared with men (5.4 +/- 1.0 vs. 1.7 +/- 0.4 microg/l, respectively) and higher basal (interpulse) GH secretion rates, which resulted in greater GH production rates and serum GH area under the curve (AUC; 1,107 +/- 194 vs. 595 +/- 146 microg x l(-1) x min, women vs. men; P = 0.04). Compared with R, Ex resulted in greater mean mass of GH secreted per burst, greater mean GH secretory burst amplitude, and greater GH AUC (1,196 +/- 211 vs. 506 +/- 90 microg x l(-1) x min, Ex vs. R, respectively; P < 0.001). During Ex, women attained maximal serum GH concentrations significantly earlier than men (24 vs. 32 min after initiation of Ex, respectively; P = 0.004). Despite this temporal disparity, both genders had similar maximal serum GH concentrations. The change in AUC (adjusted for unequal baselines) was similar for men and women (593 +/- 201 vs. 811 +/- 268 microg x l(-1) x min), but there were significant gender-by-condition interactive effects on GH secretory burst mass, pulsatile GH production rate, and maximal serum GH concentration. We conclude that, although women exhibit greater absolute GH secretion rates than men both at rest and during exercise, exercise evokes a similar incremental GH response in men and women. Thus the magnitude of the incremental secretory GH response is not gender dependent.  相似文献   

8.
The work of breathing (W(b)) normally incurred during maximal exercise not only requires substantial cardiac output and O(2) consumption (VO(2)) but also causes vasoconstriction in locomotor muscles and compromises leg blood flow (Q(leg)). We wondered whether the W(b) normally incurred during submaximal exercise would also reduce Q(leg). Therefore, we investigated the effects of changing the W(b) on Q(leg) via thermodilution in 10 healthy trained male cyclists [maximal VO(2) (VO(2 max)) = 59 +/- 9 ml. kg(-1). min(-1)] during repeated bouts of cycle exercise at work rates corresponding to 50 and 75% of VO(2 max). Inspiratory muscle work was 1) reduced 40 +/- 6% via a proportional-assist ventilator, 2) not manipulated (control), or 3) increased 61 +/- 8% by addition of inspiratory resistive loads. Increasing the W(b) during submaximal exercise caused VO(2) to increase; decreasing the W(b) was associated with lower VO(2) (DeltaVO(2) = 0.12 and 0.21 l/min at 50 and 75% of VO(2 max), respectively, for approximately 100% change in W(b)). There were no significant changes in leg vascular resistance (LVR), norepinephrine spillover, arterial pressure, or Q(leg) when W(b) was reduced or increased. Why are LVR, norepinephrine spillover, and Q(leg) influenced by the W(b) at maximal but not submaximal exercise? We postulate that at submaximal work rates and ventilation rates the normal W(b) required makes insufficient demands for VO(2) and cardiac output to require any cardiovascular adjustment and is too small to activate sympathetic vasoconstrictor efferent output. Furthermore, even a 50-70% increase in W(b) during submaximal exercise, as might be encountered in conditions where ventilation rates and/or inspiratory flow resistive forces are higher than normal, also does not elicit changes in LVR or Q(leg).  相似文献   

9.
Serum paraoxonase activity decreases in rheumatoid arthritis   总被引:6,自引:0,他引:6  
OBJECTIVE: To estimate the alterations of paraoxonase 1 (PON1) and high-density lipoprotein (HDL) in rheumatoid arthritis (RA). DESIGN AND METHODS: We investigated the serum enzyme activity and concentration of PON1 and their relationship with serum lipids, high-density lipoprotein (HDL) parameters, and acute phase reactants of serum amyloid A (SAA) and C-reactive protein (CRP) in patients with RA. RESULTS: Serum paraoxonase (PON) activity was significantly decreased in RA patients (n = 64, 131 +/- 53 micro mol/min/L) compared with healthy subjects (n = 155, 164 +/- 59) despite the absence of any difference in serum lipid levels between the two groups. This decrease of serum PON activity in RA patients was found in every genotype (Q/Q, Q/R, R/R) of PON1 at 192 Q/R. There was a different distribution in PON1 Q/R genotypes between RA patients and healthy subjects, and RA patients exhibited less (44%) positive PON1-Q than did the healthy subjects (66%). In a further investigation of age- and gender-matched subgroups of RA (n = 25) and healthy subjects (n = 25), not only serum PON activity, but also lecithin-cholesterol acyltransferase (LCAT) was found to be significantly decreased in RA patients (125 +/- 61 micro mol/min/L, 63.2 +/- 17.2 nmol/ml/hr/37 degrees C) than in healthy subjects (169 +/- 67, 74.7 +/- 19.5), respectively. PON1 and LCAT as well as HDL constituent apolipoprotein (apo) AI and apo AII, were altered significantly in RA patients. CONCLUSIONS: Acute-phase HDL, which is remodeled structurally and functionally in RA, might be less anti-atherogenic due to the impairment of original HDL function. These alterations of HDL in RA patients may explain in part the reported increase in cardiovascular mortality in patients with RA.  相似文献   

10.
In humans, multiparity (repeated pregnancy) is associated with increased risk of cardiovascular disease. In rats, multiparity increases the pressor response to phenylephrine and to acute stress, due in part to changes in tone of the splanchnic arterial vasculature. Given that the venous system also changes during pregnancy, we studied the effects of multiparity on venous tone and compliance. Cardiovascular responses to volume loading (2 ml/100 g body wt), and mean circulatory filling pressure (MCFP, an index of venomotor tone) were measured in conscious, repeatedly bred (RB), and age-matched virgin rats. In addition, passive compliance and venous reactivity of isolated mesenteric veins were measured by pressure myography. There was a greater increase in mean arterial pressure after volume loading in RB rats (+7.2 +/- 2.5 mmHg, n = 8) than virgin rats (-1.4 +/- 1.7 mmHg, n = 7) (P < 0.05). The increase in MCFP in response to norepinephrine (NE) was also greater in RB rats [half maximal effective dose (ED(50)) 3.1 +/- 0.5 nmol.kg(-1).min(-1), n = 6] than virgins (ED(50): 12.1 +/- 2.7 nmol.kg(-1).min(-1), n = 6) (P < 0.05). Pressure-induced changes in passive diameter were lower in isolated mesenteric veins from RB rats (29.3 +/- 1.8 microm/mmHg, n = 6) than from virgins (36.9 +/- 1.3 microm/mmHg, n = 6) (P < 0.05). Venous reactivity to NE in isolated veins was also greater in RB rats (EC(50): 2.68 +/- 0.37x10(-8) M, n = 5) than virgins (EC(50): 4.67 +/- 0.93 x 10(-8) M, n = 8). We conclude that repeated pregnancy induces a long-term reduction in splanchnic venous compliance and augments splanchnic venous reactivity and sympathetic tonic control of total body venous tone. This compromises the ability of the capacitance (venous) system to accommodate volume overloads and to buffer changes in cardiac preload.  相似文献   

11.
Arm blood flow at rest and during arm exercise   总被引:2,自引:0,他引:2  
To test the applicability of a dye-dilution method to quantitate total arm blood flow at rest and during arm exercise, indocyanine green was infused at a constant rate into the brachial artery. Eight subjects performed continuous 30-min arm exercises with an increase in intensity every 10 min (30, 60, and 90 W). The loads corresponded to 29 +/- 1, 48 +/- 2, and 78 +/- 4% (means +/- SE) of the maximal O2 uptake (VO2max 2.13 +/- 0.08 l/min) during arm exercise. VO2max during arm exercise was 61 +/- 1.7% of that during leg exercise. The dye concentration was analyzed in blood samples from three arm veins, two ipsi- and one contralateral, at shoulder level. Corresponding dye concentrations in both ipsilateral veins and a stable concentration difference between ipsi- and contralateral veins were achieved. Total arm blood flow was calculated to be 0.21 +/- 0.04 l/min at rest and 2.43 +/- 0.14 l/min at 90 W. Arm O2 uptake rose from 9 +/- 2 to 323 +/- 21 ml/min. Arm blood flow and O2 uptake each correlated linearly with both work load (r = 0.98) and pulmonary O2 uptake (r greater than or equal to 0.98). Mechanical efficiency for the arm and body was 34-44 and 16-19%, respectively. We conclude that arm blood flow can be determined by continuous infusion of indocyanine green.  相似文献   

12.
Pulmonary gas exchange in Andean natives (n = 8) with excessive high-altitude (3,600-4,200 m) polycythemia (hematocrit 65.1 +/- 6.6%) and hypoxemia (arterial PO2 45.6 +/- 5.6 Torr) in the absence of pulmonary or cardiovascular disease was investigated both before and after isovolemic hemodilution by use of the inert gas elimination technique. The investigations were carried out in La Paz, Bolivia (3,650 m, 500 mmHg barometric pressure). Before hemodilution, a low ventilation-perfusion (VA/Q) mode (VA/Q less than 0.1) without true shunt accounted for 11.6 +/- 5.5% of the total blood flow and was mainly responsible for the hypoxemia. The hypoventilation with a low mixed venous PO2 value may have contributed to the observed hypoxemia in the absence of an impairment in alveolar capillary diffusion. After hemodilution, cardiac output and ventilation increased from 5.5 +/- 1.2 to 6.9 +/- 1.2 l/min and from 8.5 +/- 1.4 to 9.6 +/- 1.3 l/min, respectively, although arterial and venous PO2 remained constant. VA/Q mismatching fell slightly but significantly. The hypoxemia observed in subjects suffering from high-altitude excessive polycythemia was attributed to an increased in blood flow perfusing poorly ventilated areas, but without true intra- or extrapulmonary shunt. Hypoventilation as well as a low mixed venous PO2 value may also have contributed to the observed hypoxemia.  相似文献   

13.
We studied the spatial distribution of the abnormal ventilation-perfusion (Va/Q) units in a porcine model of acute pulmonary thromboembolism (APTE), using the fluorescent microsphere (FMS) technique. Four piglets ( approximately 22 kg) were anesthetized and ventilated with room air in the prone position. Each received approximately 20 g of preformed blood clots at time t = 0 min via a large-bore central venous catheter, until the mean pulmonary arterial pressure reached 2.5 times baseline. The distributions of regional Va and blood flow (Q) at five time points (t = -30, -5, 30, 60, 120 min) were mapped by FMS of 10 distinct colors, i.e., aerosolization of 1-mum FMS for labeling Va and intravenous injection of 15-mum FMS for labeling Q. Our results showed that, at t = 30 min following APTE, mean Va/Q (Va/Q = 2.48 +/- 1.12) and Va/Q heterogeneity (log SD Va/Q = 1.76 +/- 0.23) were significantly increased. There were also significant increases in physiological dead space (11.2 +/- 12.7% at 60 min), but the shunt fraction (Va/Q = 0) remained minimal. Cluster analyses showed that the low Va/Q units were mainly seen in the least embolized regions, whereas the high Va/Q units and dead space were found in the peripheral subpleural regions distal to the clots. At 60 and 120 min, there were modest recoveries in the hemodynamics and gas exchange toward baseline. Redistribution pattern was mostly seen in regional Q, whereas Va remained relatively unchanged. We concluded that the hypoxemia seen after APTE could be explained by the mechanical diversion of Q to the less embolized regions because of the vascular obstruction by clots elsewhere. These low Va/Q units created by high flow, rather than low Va, accounted for most of the resultant hypoxemia.  相似文献   

14.
Aim of the present study was to evaluate whether the inhibitory effect of somatostatin on pancreatic B-cell secretion is normal in nondiabetic obese subjects. For this purpose plasma C-peptide concentrations were measured in 10 nondiabetic obese subjects and 10 nonobese healthy controls during a 4-h hyperglycemic (11 mmol/l) glucose clamp. Somatostatin was infused (2.5 nmol/min) during the third hour of the study period in order to inhibit glucose-stimulated B-cell secretion. Fasting C-peptide averaged 0.46 +/- 0.04 nmol/l (mean +/- SEM) in nonobese subjects, and 0.85 +/- 0.08 nmol/l in obese patients (P less than 0.001). In the period 0-120 min the area under the plasma C-peptide curve was significantly higher in obese than in nonobese subjects (292 +/- 23 vs. 230 +/- 17 nmol/l x 120 min, P less than 0.05), however, in the last 20 min of the glucose infusion period without somatostatin (100-120 min) plasma C-peptide was not significantly different in the two groups (2.94 +/- 0.32 nmol/l in nonobese subjects and 3.21 +/- 0.19 nmol/l in obese patients, p = NS). During somatostatin infusion while maintaining hyperglycemia, plasma C-peptide decreased in both groups, and in the period 160-180 min it averaged 0.89 +/- 0.12 nmol/l in control subjects and 0.93 +/- 0.08 nmol/l in obese patients (P = NS), with a percent reduction similar in the two groups (70 +/- 2% in controls and 71 +/- 2% in obese patients). After discontinuing somatostatin infusion, plasma C-peptide increased to concentrations which were higher in obese than in nonobese subjects.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
Patients with obstructive lung disease are exposed to expiratory loads (ELs) and dynamic hyperinflation as a consequence of expiratory flow limitation. To understand how these alterations in lung mechanics might affect cardiac function, we examined the influence of a 10-cm H2O EL, alone and in combination with voluntary hyperinflation (ELH), on pulmonary pressures [esophageal (Pes) and gastric (Pg)] and cardiac output (CO) in seven healthy subjects. CO was determined by using an acetylene method at rest and at 40 and 70% of peak work. At rest and during exercise, EL resulted in an increase in Pes and Pg (7-18 cm H2O; P < 0.05) and a decrease in CO (from 5.3 +/- 1.8 to 4.5 +/- 1.4, 12.2 +/- 2.2 to 11.2 +/- 2.2, and 16.3 +/- 3.3 to 15.2 +/- 3.2 l/min for rest, 40% peak work, and 70% peak work, respectively; P < 0.05), which remained depressed after an additional 2 min of EL. With ELH, CO increased at rest and both exercise loads (relative to EL only) but remained below control values. The changes in CO were due to a reduction in stroke volume with a tendency for stroke volume to fall further with prolonged EL. There was a negative correlation between CO and the increase in expiratory Pes and Pg with EL (R = -0.58 and -0.60; P < 0.01), whereas the rise in CO with subsequent hyperinflation was related to a more negative Pes (R = 0.72; P < 0.01). In conclusion, EL leads to a reduction in CO, which appears to be primarily related to increases in expiratory abdominal and intrathoracic pressure, whereas ELH resulted in an improved CO, suggesting that lung inflation has little impact on cardiac function.  相似文献   

16.
Currently, no reliable minimally invasive method of measuring cardiac output continuously in neonates and children undergoing cardiac surgery is available. An extravascular Doppler probe was used to measure cardiac output in 15 New Zealand White rabbits (average weight 3.5 kg, range 2.5-4.5 kg). The results obtained were compared with cardiac outputs determined using the aortic thermodilution principle. The mean cardiac outputs measured with the extravascular Doppler probe was 0.37 +/- 0.01 l/min as compared with 0.39 +/- 0.01 l/min with aortic thermodilution. Regression analysis revealed a close correlation (r = 0.973) between the two techniques. The extravascular Doppler techniques is an option for continuous and reliable cardiac output measurement in small animals used in surgical experiments (open chest models) and in neonates or children during surgical repair of complicated congenital heart conditions.  相似文献   

17.
The oral and nasal contributions to inhaled ventilation were simultaneously quantified during sleep in 10 healthy subjects (5 men, 5 women) aged 43 +/- 5 yr, with normal nasal resistance (mean 2.0 +/- 0.3 cmH(2)O. l(-1). s(-1)) by use of a divided oral and nasal mask. Minute ventilation awake (5.9 +/- 0.3 l/min) was higher than that during sleep (5.2 +/- 0.3 l/min; P < 0.0001), but there was no significant difference in minute ventilation between different sleep stages (P = 0.44): stage 2 5.3 +/- 0.3, slow-wave 5.2 +/- 0.2, and rapid-eye-movement sleep 5.2 +/- 0.2 l/min. The oral fraction of inhaled ventilation during wakefulness (7.6 +/- 4%) was not significantly different from that during sleep (4.3 +/- 2%; mean difference 3.3%, 95% confidence interval -2.1-8.8%, P = 0.19), and no significant difference (P = 0.14) in oral fraction was observed between different sleep stages: stage two 5.1 +/- 2.8, slow-wave 4.2 +/- 1.8, rapid-eye-movement 3.1 +/- 1.7%. Thus the inhaled oral fraction in normal subjects is small and does not change significantly with sleep stage.  相似文献   

18.
We have recently reported that exposure of rat hearts to high Ca(2+) produces a Ca(2+) overload-induced contractile failure in rat hearts, which was associated with proteolysis of alpha-fodrin. We hypothesized that contractile failure after ischemia-reperfusion (I/R) is similar to that after high Ca(2+) infusion. To test this hypothesis, we investigated left ventricular (LV) mechanical work and energetics in the cross-circulated rat hearts, which were subjected to 15 min global ischemia and 60 min reperfusion. Sixty minutes after I/R, mean systolic pressure-volume area (PVA; a total mechanical energy per beat) at midrange LV volume (mLVV) (PVA(mLVV)) was significantly decreased from 5.89 +/- 1.55 to 3.83 +/- 1.16 mmHg.ml.beat(-1).g(-1) (n = 6). Mean myocardial oxygen consumption per beat (Vo(2)) intercept of (Vo(2)-PVA linear relation was significantly decreased from 0.21 +/- 0.05 to 0.15 +/- 0.03 microl O(2).beat(-1).g(-1) without change in its slope. Initial 30-min reperfusion with a Na(+)/Ca(2+) exchanger (NCX) inhibitor KB-R7943 (KBR; 10 micromol/l) significantly reduced the decrease in mean PVA(mLVV) and Vo(2) intercept (n = 6). Although Vo(2) for the Ca(2+) handling was finally decreased, it transiently but significantly increased from the control for 10-15 min after I/R. This increase in Vo(2) for the Ca(2+) handling was completely blocked by KBR, suggesting an inhibition of reverse-mode NCX by KBR. alpha-Fodrin proteolysis, which was significantly increased after I/R, was also significantly reduced by KBR. Our study shows that the contractile failure after I/R is similar to that after high Ca(2+) infusion, although the contribution of reverse-mode NCX to the contractile failure is different. An inhibition of reverse-mode NCX during initial reperfusion protects the heart against reperfusion injury.  相似文献   

19.
Eight normal subjects were decompressed to barometric pressure (PB) = 240 Torr over 40 days. The ventilation-perfusion (VA/Q) distribution was estimated at rest and during exercise [up to 80-90% maximal O2 uptake (VO2 max)] by the multiple inert gas elimination technique at sea level and PB = 428, 347, 282, and 240 Torr. The dispersion of the blood flow distribution increased by 64% from rest to 281 W, at both sea level and at PB = 428 Torr (heaviest exercise 215 W). At PB = 347 Torr, the increase was 79% (rest to 159 W); at PB = 282 Torr, the increase was 112% (108 W); and at PB = 240 Torr, the increase was 9% (60 W). There was no significant correlation between the dispersion and cardiac output, ventilation, or pulmonary arterial wedge pressure, but there was a correlation between the dispersion and mean pulmonary arterial pressure (r = 0.49, P = 0.02). When abnormal, the VA/Q pattern generally had perfusion in lung units of zero or near zero VA/Q combined with units of normal VA/Q. Alveolar-end-capillary diffusion limitation of O2 uptake (VO2) was observed at VO2 greater than 3 l/min at sea level, greater than 1-2 l/min VO2 at PB = 428 and 347 Torr, and at higher altitudes, at VO2 less than or equal to 1 l/min. These results show variable but increasing VA/Q mismatch with long-term exposure to both altitude and exercise. The VA/Q pattern and relationship to pulmonary arterial pressure are both compatible with alveolar interstitial edema as the primary cause of inequality.  相似文献   

20.
Previous studies (J. Appl. Physiol. 58: 978-988 and 989-995, 1985) have shown both worsening ventilation-perfusion (VA/Q) relationships and the development of diffusion limitation during heavy exercise at sea level and during hypobaric hypoxia in a chamber [fractional inspired O2 concentration (FIO2) = 0.21, minimum barometric pressure (PB) = 429 Torr, inspired O2 partial pressure (PIO2) = 80 Torr]. We used the multiple inert gas elimination technique to compare gas exchange during exercise under normobaric hypoxia (FIO2 = 0.11, PB = 760 Torr, PIO2 = 80 Torr) with earlier hypobaric measurements. Mixed expired and arterial respiratory and inert gas tensions, cardiac output, heart rate (HR), minute ventilation, respiratory rate (RR), and blood temperature were recorded at rest and during steady-state exercise in 10 normal subjects in the following order: rest, air; rest, 11% O2; light exercise (75 W), 11% O2; intermediate exercise (150 W), 11% O2; heavy exercise (greater than 200 W), 11% O2; heavy exercise, 100% O2 and then air; and rest 20 minutes postexercise, air. VA/Q inequality increased significantly during hypoxic exercise [mean log standard deviation of perfusion (logSDQ) = 0.42 +/- 0.03 (rest) and 0.67 +/- 0.09 (at 2.3 l/min O2 consumption), P less than 0.01]. VA/Q inequality was improved by relief of hypoxia (logSDQ = 0.51 +/- 0.04 and 0.48 +/- 0.02 for 100% O2 and air breathing, respectively). Diffusion limitation for O2 was evident at all exercise levels while breathing 11% O2.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号