共查询到20条相似文献,搜索用时 31 毫秒
1.
Chunjuan Sun Yinghua Pan Hongbo Wang Jian Li Pei Nie Ximing Wang Heng Ma Futao Huo 《PloS one》2014,9(8)
Purpose
To investigate the coronary venous system and its relation to adjacent structures using 256-slice computed tomography (CT).Materials and Methods
The study consisted of 102 patients who underwent coronary CT angiography (CTA) using 256-slice CT. For each patient, the coronary venous system and its relation to adjacent structures were evaluated. The appropriate locations and diameters of the posterior interventricular vein (PIV), posterior vein of the left ventricle (PVLV) and the left marginal vein (LMV) were detected. The paired student''s t test was used to evaluate the difference between the diameter of the coronary sinus (CS) ostium in anteroposterior direction and that in superoinferior direction.Results
The CS, great cardiac vein (GCV), PIV, and anterior interventricular vein (AIV) were visualized in all cases. It was possible to evaluate at least one main vein with adequate caliber and regular course for cardiac resynchronization therapy (CRT) in 96.1% of these cases. The diameter of the CS ostium in superoinferior direction (11.7±2.1 mm) was larger than that in anteroposterior direction (9.0±2.0 mm) (t = 13.511, P<0.05). For the majority of the cases, the CS-GCV was located above the level of the mitral valve annulus (MVA), while the left circumflex coronary artery (LCX) was coursed between the CS-GCV and the MVA. LMV had more intersection with the circumflex or circumflex marginal than PVLV.Conclusion
256-slice CT provides superior noninvasive evaluation of the coronary venous system which has important clinical implications. 相似文献2.
3.
Elza van Deel Yanto Ridwan J. Nicole van Vliet Sasha Belenkov Jeroen Essers 《Journal of visualized experiments : JoVE》2016,(108)
The use of Micro-Computed Tomography (MicroCT) for in vivo studies of small animals as models of human disease has risen tremendously due to the fact that MicroCT provides quantitative high-resolution three-dimensional (3D) anatomical data non-destructively and longitudinally. Most importantly, with the development of a novel preclinical iodinated contrast agent called eXIA160, functional and metabolic assessment of the heart became possible. However, prior to the advent of commercial MicroCT scanners equipped with X-ray flat-panel detector technology and easy-to-use cardio-respiratory gating, preclinical studies of cardiovascular disease (CVD) in small animals required a MicroCT technologist with advanced skills, and thus were impractical for widespread implementation. The goal of this work is to provide a practical guide to the use of the high-speed Quantum FX MicroCT system for comprehensive determination of myocardial global and regional function along with assessment of myocardial perfusion, metabolism and viability in healthy mice and in a cardiac ischemia mouse model induced by permanent occlusion of the left anterior descending coronary artery (LAD). 相似文献
4.
Xiang-Ran Cai Qing-Chun Zhou Juan Yu You-Zhen Feng Zhao-Hui Xian Wen-Cai Yang Xu-Kai Mo 《PloS one》2015,10(4)
Background
Obstructed nephropathy is a common complication of several disease processes. Accurate evaluation of the functional status of the obstructed kidney is important to achieve a good outcome. The purpose of this study was to investigate renal cortical and medullary perfusion changes associated with unilateral ureteral obstruction (UUO) using whole-organ perfusion imaging with 320-detector row computed tomography (CT).Methodology/Principle Findings
Sixty-four patients with UUO underwent whole-organ CT perfusion imaging. Patients were divided into 3 groups, mild, moderate, and severe, based on hydronephrosis severity. Twenty sex- and age-matched patients without renal disease, who referred to abdominal CT, were chosen as control subjects. Mean cortical and medullary perfusion parameters of obstructed and contralateral kidneys were compared, and mean perfusion ratios between obstructed and contralateral kidneys were calculated and compared. Mean cortical or medullary blood flow (BF) and blood volume (BV) of the obstructed kidneys in the moderate UUO and BF, BV, and clearance (CL) in the severe UUO were significantly lower than those of the contralateral kidneys (p < 0.05). The mean cortical or medullary BF of the obstructed kidney in the moderate UUO, and BF, BV, and CL in the severe UUO were significantly lower than those of the kidneys in control subjects (p < 0.05). Mean cortical or medullary BF of the non-obstructed kidneys in the severe UUO were statistically greater than that of normal kidneys in control subjects (p < 0.05). An inverse correlation was observed between cortical and medullary perfusion ratios and grades of hydronephosis (p < 0.01).Conclusions/Significance
Perfusion measurements of the whole kidney can be obtained with 320-detector row CT, and estimated perfusion ratios have potential for quantitatively evaluating UUO renal injury grades. 相似文献5.
6.
Quantitative Extraction of Adenosine Triphosphate from Cultivable and Host-Grown Microbes: Calculation of Adenosine Triphosphate Pools 总被引:6,自引:4,他引:6 下载免费PDF全文
Existing data on adenosine triphosphate (ATP) pools in microbes are deficient for two reasons: (i) incomplete extractions of ATP, and (ii) the failure to take into account that the adverse effects of extracting procedures on standard ATP exert analogous effects on the ATP released from bacterial cells. Methods for correcting observed yields and calculating ATP pools have been demonstrated. Three bacterial species were used in the studies on extraction of ATP: Escherichia coli, Mycobacterium phlei, and Mycobacterium lepraemurium. Perchloric acid and n-butanol were disqualified because of their failure to extract total bacterial ATP even from E. coli and because of inconvenient procedures. The new extraction procedure had minimal effects on standard ATP, liberated 100% of the ATP pools from the three representative species of microbes, and caused no ionic imbalance or quenching of bioluminescence. This method involves vortexing of cell suspensions for 10 s with 23% chloroform (vol/vol), heating at 98 C for the required time (E. coli, 3 min; M. phlei, 5 min; M. lepraemurium, 10 min) and then 1 min at 98 C with vacuum to dry the samples. Heat or chloroform alone may suffice for some microbes and release total ATP from plant and animal cells. 相似文献
7.
Yoram Vodovotz Andrew Hsing John A. Cook Robert W. Miller David A. Wink Daniel M. Ritt James B. Mitchell David Danielpour 《Analytical biochemistry》1997,250(2):147
Apoptosis is an important and common pathway of cellular death. Differentiation from cellular necrosis and quantitation of apoptosis within the milieu of necrosis are analytical challenges. We describe the use of the RIT120 digital imaging software package for quantitative and qualitative analysis of apoptotic DNA ladders induced by a variety of agents, such as serum, tumor necrosis factor-α, transforming growth factor-β1, and nitric oxide. Autoradiographs of DNA ladders are densitometrically scanned to yield a set of curves with peaks corresponding to specific DNA fragments, thereby allowing quantitative subtraction of concurrent DNA degradation from necrotic death. Integration of the areas specifically under the peaks yields a quantitative measure of apoptosis. We provide a useful, rapid, and objective means to quantitate apoptosis, using relatively inexpensive hardware and software. 相似文献
8.
Ali Asgar Attarwala Flavia Molina-Duran Karen-Anett Büsing Stefan O. Sch?nberg Dale L. Bailey Kathy Willowson Gerhard Glatting 《PloS one》2014,9(11)
Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with 90Y labeled microspheres. The aim of this work was to image and quantify 90Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia). A NEMA IEC body phantom containing 6 fillable spheres (10–37 mm ∅) was used to measure the 90Y distribution with a Biograph mCT PET/CT (Siemens, Erlangen, Germany) with time-of-flight (TOF) acquisition. A sphere to background ratio of 8∶1, with a total 90Y activity of 3 GBq was used. Measurements were performed for one week (0, 3, 5 and 7 d). he acquisition protocol consisted of 30 min-2 bed positions and 120 min-single bed position. mages were reconstructed with 3D ordered subset expectation maximization (OSEM) and point spread function (PSF) for iteration numbers of 1–12 with 21 (TOF) and 24 (non-TOF) subsets and CT based attenuation and scatter correction. Convergence of algorithms and activity recovery was assessed based on regions-of-interest (ROI) analysis of the background (100 voxels), spheres (4 voxels) and the central low density insert (25 voxels). For the largest sphere, the recovery coefficient (RC) values for the 30 min –2-bed position, 30 min-single bed and 120 min-single bed were 1.12±0.20, 1.14±0.13, 0.97±0.07 respectively. For the smaller diameter spheres, the PSF algorithm with TOF and single bed acquisition provided a comparatively better activity recovery. Quantification of Y-90 using Biograph mCT PET/CT is possible with a reasonable accuracy, the limitations being the size of the lesion and the activity concentration present. At this stage, based on our study, it seems advantageous to use different protocols depending on the size of the lesion. 相似文献
9.
Kazuhiro Osawa Toru Miyoshi Takashi Miki Yasushi Koyama Shuhei Sato Susumu Kanazawa Hiroshi Ito 《PloS one》2016,11(2)
Coronary computed tomography angiography (CCTA) in combination with first-pass CT myocardial perfusion imaging (MPI) has a better diagnostic performance than CCTA alone, compared with invasive coronary angiography as the reference standard. The aim of this study was to investigate the additional diagnostic value of first-pass CT-MPI without stress for detecting hemodynamic significance of coronary stenosis, compared with invasive fractional flow reserve (FFR). We recruited 53 patients with suspected coronary artery disease undergoing both CCTA and first-pass CT-MPI without stress and invasive FFR, and 75 vessels were analyzed. We used the same raw data for CCTA and CT-MPI. First-pass CT-MPI was reconstructed by examining the diastolic signal densities as a bull’s eye map. Invasive FFR <0.8 was considered as positive. On per-vessel analysis, the area under the receiver operating characteristic curve for CCTA plus first-pass CT-MPI and CCTA alone was 0.81 (0.73–0.90) and 0.70 (0.61–0.81), respectively (P = 0.036). CCTA plus first-pass CT-MPI without stress showed 0.73 sensitivity, 0.74 specificity, 0.53 positive predictive value, and 0.87 negative predictive value for detecting hemodynamically significant coronary stenosis. First-pass CT-MPI without stress correctly reclassified 38% of CCTA false-positive vessels as true negative. First-pass CT-MPI without stress combined with CCTA demonstrated excellent diagnostic accuracy, compared with invasive FFR as the reference standard. This technique could complement CCTA for diagnosis of coronary artery disease. 相似文献
10.
11.
In 2010 approximately 68,720 melanomas will be diagnosed in the US alone, with around 8,650 resulting in death 1. To date, the only effective treatment for melanoma remains surgical excision, therefore, the key to extended survival is early detection 2,3. Considering the large numbers of patients diagnosed every year and the limitations in accessing specialized care quickly, the development of objective in vivo diagnostic instruments to aid the diagnosis is essential. New techniques to detect skin cancer, especially non-invasive diagnostic tools, are being explored in numerous laboratories. Along with the surgical methods, techniques such as digital photography, dermoscopy, multispectral imaging systems (MelaFind), laser-based systems (confocal scanning laser microscopy, laser doppler perfusion imaging, optical coherence tomography), ultrasound, magnetic resonance imaging, are being tested. Each technique offers unique advantages and disadvantages, many of which pose a compromise between effectiveness and accuracy versus ease of use and cost considerations. Details about these techniques and comparisons are available in the literature 4.Infrared (IR) imaging was shown to be a useful method to diagnose the signs of certain diseases by measuring the local skin temperature. There is a large body of evidence showing that disease or deviation from normal functioning are accompanied by changes of the temperature of the body, which again affect the temperature of the skin 5,6. Accurate data about the temperature of the human body and skin can provide a wealth of information on the processes responsible for heat generation and thermoregulation, in particular the deviation from normal conditions, often caused by disease. However, IR imaging has not been widely recognized in medicine due to the premature use of the technology 7,8 several decades ago, when temperature measurement accuracy and the spatial resolution were inadequate and sophisticated image processing tools were unavailable. This situation changed dramatically in the late 1990s-2000s. Advances in IR instrumentation, implementation of digital image processing algorithms and dynamic IR imaging, which enables scientists to analyze not only the spatial, but also the temporal thermal behavior of the skin 9, allowed breakthroughs in the field.In our research, we explore the feasibility of IR imaging, combined with theoretical and experimental studies, as a cost effective, non-invasive, in vivo optical measurement technique for tumor detection, with emphasis on the screening and early detection of melanoma 10-13. In this study, we show data obtained in a patient study in which patients that possess a pigmented lesion with a clinical indication for biopsy are selected for imaging. We compared the difference in thermal responses between healthy and malignant tissue and compared our data with biopsy results. We concluded that the increased metabolic activity of the melanoma lesion can be detected by dynamic infrared imaging. 相似文献
12.
Ansgar Reising Saskia Sambale Frank Donnerstag Julius J. Schmidt Carsten Hafer Bernhard M.W. Schmidt Jan T. Kielstein 《PloS one》2013,8(2)
Background
Patients undergoing hemodialysis treatment have a six-fold increased risk for stroke relative to the general population. However, the effect of hemodialysis on cerebral blood flow is poorly studied and confounding factors like blood pressure and ultrafiltration as well as temperature changes have rarely been accounted for. The aim of our study was to use state-of-the-art technology to evaluate the effect of a single dialysis session on cerebral perfusion as well as on vascular stiffness.Methods
Chronic hemodialysis patients (7 male/3 female, mean age 58 years) were recruited. Cerebral blood flow and arterial pulse wave velocity were measured before and immediately after a hemodialysis session. To exclude effects of volume changes we kept ultrafiltration to a minimum, allowing no change in body weight. Isothermic conditions were maintained by using the GENIUS single-pass batch-dialysis system with a high-flux polysulfone dialyser. Cerebral blood flow was measured by contrast-enhanced computed tomography. Pulse wave velocity was measured using the SphygmoCor (AtCor Medical, USA) device by a single operator.Results
This study shows for the first time that isovolemic, isothermic hemodialysis neither affected blood pressure or heart rate, nor total or regional cerebral perfusion. There was also no change in pulse wave velocity.Conclusions
Mechanisms other than the dialysis procedure itself might be causative for the high incidence of ischemic strokes in this patient population. Moreover, the sole removal of uremic toxins does not lead to short-term effects on vascular stiffness, underlying the importance of volume control in this patient population. 相似文献13.
Qian Xie Juan Wu Ying Tang Yafang Dou Sijie Hao Feijia Xu Xiaoyuan Feng Zonghui Liang 《PloS one》2013,8(11)
Background
This study was performed to assess whether iterative reconstruction can reduce radiation dose while maintaining acceptable image quality, and to investigate whether perfusion parameters vary from conventional filtered back projection (FBP) at the low-tube-voltage (80-kVp) during whole-pancreas perfusion examination using a 256-slice CT.Methods
76 patients with known or suspected pancreatic mass underwent whole-pancreas perfusion by a 256-slice CT. High- and low-tube-voltage CT images were acquired. 120-kVp image data (protocol A) and 80-kVp image data (protocol B) were reconstructed with conventional FBP, and 80-kVp image data were reconstructed with iDose4 (protocol C) iterative reconstruction. The image noise; contrast-to-noise ratio (CNR) relative to muscle for the pancreas, liver, and aorta; and radiation dose of each protocol were assessed quantitatively. Overall image quality was assessed qualitatively. Among 76 patients, 23 were eventually proven to have a normal pancreas. Perfusion parameters of normal pancreas in each protocol including blood volume, blood flow, and permeability-surface area product were measured.Results
In the quantitative study, protocol C reduced image noise by 36.8% compared to protocol B (P<0.001). Protocol C yielded significantly higher CNR relative to muscle for the aorta, pancreas and liver compared to protocol B (P<0.001), and offered no significant difference compared to protocol A. In the qualitative study, protocols C and A gained similar scores and protocol B gained the lowest score for overall image quality (P<0.001). Mean effective doses were 23.37 mSv for protocol A and 10.81 mSv for protocols B and C. There were no significant differences in the normal pancreas perfusion values among three different protocols.Conclusion
Low-tube-voltage and iDose4 iterative reconstruction can dramatically decrease the radiation dose with acceptable image quality during whole-pancreas CT perfusion and have no significant impact on the perfusion parameters of normal pancreas compared to the conventional FBP reconstruction using a 256-slice CT scanner. 相似文献14.
Murine models for rheumatoid arthritis (RA) research can provide important insights for understanding RA pathogenesis and evaluating the efficacy of novel treatments. However, simultaneously imaging both murine articular cartilage and subchondral bone using conventional techniques is challenging because of low spatial resolution and poor soft tissue contrast. X-ray phase-contrast imaging (XPCI) is a new technique that offers high spatial resolution for the visualisation of cartilage and skeletal tissues. The purpose of this study was to utilise XPCI to observe articular cartilage and subchondral bone in a collagen-induced arthritis (CIA) murine model and quantitatively assess changes in the joint microstructure. XPCI was performed on the two treatment groups (the control group and CIA group, n = 9 per group) to monitor the progression of damage to the femur from the knee joint in a longitudinal study (at 0, 4 and 8 weeks after primary injection). For quantitative assessment, morphologic parameters were measured in three-dimensional (3D) images using appropriate image analysis software. Our results showed that the average femoral cartilage volume, surface area and thickness were significantly decreased (P<0.05) in the CIA group compared to the control group. Meanwhile, these decreases were accompanied by obvious destruction of the surface of subchondral bone and a loss of trabecular bone in the CIA group. This study confirms that XPCI technology has the ability to qualitatively and quantitatively evaluate microstructural changes in mouse joints. This technique has the potential to become a routine analysis method for accurately monitoring joint damage and comprehensively assessing treatment efficacy. 相似文献
15.
Objective
Coronary artery disease (CAD) is associated with abdominal obesity and metabolic syndrome. Adipocytes secrete adipokines, including the newly discovered adipocyte fatty acid binding protein (A-FABP) and chemerin. Adipokines contribute to the pathogenesis of CAD. In patients with CAD, the presence of significant ischemia predicts adverse outcomes. It is unknown whether adipokines can be better predictors of the presence of significant myocardial ischemia than conventional risk factors. This study aimed to compare adipokines with clinical risk factors and abdominal obesity as predictive factors for significant myocardial ischemia.Methods
One hundred and ninety-six adults with suspected, but unproven, CAD were consecutively enrolled. The main measures were clinical and biochemical parameters and stress myocardial perfusion imaging with gated myocardial perfusion single-photon emission computed tomography (SPECT), with computed tomography (CT) attenuation correction. The abdominal visceral fat area was examined using a hybrid SPECT/CT scanner. Serum levels of high-sensitivity C-reactive protein (hs-CRP) and adipokines (adiponectin, A-FABP, and chemerin) were evaluated.Results
A-FABP levels correlated significantly with adiponectin, hs-CRP, body mass index, waist circumference, and visceral fat area. A-FABP was significantly associated with metabolic syndrome (OR 3.2, 95% CI 1.6–6.4, p = 0.001), significant myocardial ischemia (OR 1.9, 95% CI 1.0–3.4, p = 0.05), and stress lung-to-heart ratio (β = 0.03, p = 0.03) on SPECT. Chemerin was significantly associated with serum triglyceride levels but not with metabolic syndrome, significant ischemia, or stress lung-to-heart ratio on SPECT. A-FABP was better at detecting significant inducible ischemia than other biomarkers, although this was a modest improvement (area under ROC curve 0.579, 95% CI 0.46–0.69).Conclusions
Serum A-FABP concentrations correlate significantly with visceral fat area, metabolic syndrome, and predicted significant myocardial ischemia on SPECT. This may help to more accurately assess CAD risk, especially in patients with metabolic syndrome. 相似文献16.
Background
The aims of this study were to investigate the image quality and radiation exposure of pediatric protocols for cardiac CT angiography (CTA) in infants under one year of age.Methodology/Principal Findings
Cardiac CTA examinations were performed using an anthropomorphic phantom representing a 1-year-old child scanned with non-electrocardiogram-gated (NG), retrospectively electrocardiogram-gated helical (RGH) and prospectively electrocardiogram-gated axial (PGA) techniques in 64-slice and 256-slice CT scanners. The thermoluminescent dosimeters (TLD) were used for direct organ dose measurement, while dose-length product and effective mAs were also used to estimate the patient dose. For image quality, noise and signal-to-noise-ratio (SNR) were assessed based on regions-of-interest drawn on the reconstructed CT images, and were compared with the proposed cardiac image quantum index (CIQI). Estimated dose results were in accordant to the measured doses. The NG scan showed the best image quality in terms of noise and SNR. The PGA scan had better image quality than the RGH scan with 83.70% dose reduction. Noise and SNR were also corresponded to the proposed CIQI.Conclusions/Significance
The PGA scan protocol was a good choice in balancing radiation exposure and image quality for infant cardiac CTA. We also suggested that the effective mAs and the CIQI were suitable in assessing the tradeoffs between radiation dose and image quality for cardiac CTA in infants. These results are useful for future implementation of dose reduction strategies in pediatric cardiac CTA protocols. 相似文献17.
Wesley A Clarkson Carlos Santiago Restrepo Terry D Bauch Bernard J Rubal 《Comparative medicine》2009,59(6):573-579
This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed coronary vasodilation at baseline and after intravenous adenosine (140 µg/kg/min) or sublingual nitroglycerin spray (800 µg) in 7 female swine (weight, 40.9 ± 1.4 kg) by using electrocardiogram-gated coronary angiography with a 64-detector scanner (rotation time, 400 ms; 120kV; 400 mA) and intravenous contrast (300 mg/mL iohexol, 4.5 mL/s, 2 mL/kg). Cross-sectional areas of segments in the left anterior descending, circumflex, and right coronary arteries were evaluated in oblique orthogonal views. Images were acquired at an average heart rate of 73 ± 11 beats per minute. Changes in aortic pressure were not significant with nitroglycerin but decreased (approximately 10%) with adenosine. Of the 76 segments analyzed (baseline range, 2 to 39 mm2), 1 distal segment could not be assessed after adenosine. Segment cross-sectional area increased by 11.3% with nitroglycerin but decreased by 9.6% during adenosine infusion. The results of the present study are consistent with the practice of using sublingual nitroglycerin to enhance visualization of epicardial vessels and suggest that intravenous adenosine may hinder coronary artery visualization. This study is the first repeated-measures electrocardiogram-gated CT evaluation to use the same imaging technology to assess changes in coronary cross-sectional area before and after treatment with a vasodilator. The nitroglycerin-associated changes in our swine model were modest in comparison with previously reported human studies.Abbreviations: LAD, left anterior descending artery; MDCT, multidetector computed tomographyRecent advances in multidetector computed tomography (MDCT) for coronary angiography, their increased availability, and the pending release of a new generation of CT scanners contribute to this methodology''s potential for revolutionizing the early diagnosis and functional assessment of coronary artery disease.15,16,25 However, the benefits of methodologic advances do not diminish the need to validate and assess the safety, efficacy, and costs of technology.15 In this regard, the present study uses an animal model with coronary anatomy analogous to that of humans11,43 to assess the effects of sublingual nitroglycerin and intravenous adenosine on coronary epicardial vessel visualization by using baseline imaging as a control. The radiation exposure associated with CT procedures precludes human studies that involve repeated measures on the same subjects.Sublingual nitroglycerin is hypothesized to enhance the visualization of epicardial coronary vessels due to its vasodilatory properties.8-10 Nitroglycerin acts as a nitric oxide generator to induce relaxation of vascular smooth muscle independent of endothelial function.1,18,20 Current evidence supporting improved coronary visualization with sublingual nitroglycerin is derived from clinical cross-sectional studies that compare results in different groups of patients with heterogeneous coronary lesions.5,6,16,27,44 A recent survey reported that more than 80% of facilities in the United States routinely use nitroglycerin in cardiac MDCT angiography.23In contrast to the action of nitroglycerin on epicardial vascular smooth muscle, intravenous adenosine frequently is used as a pharmacologic stress to affect vasodilatation within the coronary microcirculation.20 Although current-generation CT scanners have limited capability to assess myocardial tissue perfusion, research efforts from advanced imaging centers suggest that future-generation CT scanners soon will permit myocardial perfusion imaging.13,14,29 No studies to date have assessed epicardial vessel changes by MDCT with intravenous doses of adenosine appropriate for myocardial perfusion imaging.The objective of this study was to provide an animal model for MDCT studies that permits repeated measures of epicardial vessels without the limitations of cross-sectional designs or the complications of heterogeneity of vascular lesions within clinical populations. This study used routes of administration of nitroglycerin and adenosine that are consistent with clinical practice. 相似文献
18.
Objectives
Companion dogs with naturally occurring cancer serve as an important large animal model in translational research because they share strong similarities with human cancers. In this study, we investigated a long circulating liposomal-iodine contrast agent (Liposomal-I) for computed tomography (CT) imaging of solid tumors in companion dogs with naturally occurring cancer.Materials and Methods
The institutional animal ethics committees approved the study and written informed consent was obtained from all owners. Thirteen dogs (mean age 10.1 years) with a variety of masses including primary and metastatic liver tumors, sarcomas, mammary carcinoma and lung tumors, were enrolled in the study. CT imaging was performed pre-contrast and at 15 minutes and 24 hours after intravenous administration of Liposomal-I (275 mg/kg iodine dose). Conventional contrast-enhanced CT imaging was performed in a subset of dogs, 90 minutes prior to administration of Liposomal-I. Histologic or cytologic diagnosis was obtained for each dog prior to admission into the study.Results
Liposomal-I resulted in significant (p < 0.05) enhancement and uniform opacification of the vascular compartment. Non-renal, reticulo-endothelial systemic clearance of the contrast agent was demonstrated. Liposomal-I enabled visualization of primary and metastatic liver tumors. Sub-cm sized liver lesions grossly appeared as hypo-enhanced compared to the surrounding normal parenchyma with improved lesion conspicuity in the post-24 hour scan. Large liver tumors (> 1 cm) demonstrated a heterogeneous pattern of intra-tumoral signal with visibly higher signal enhancement at the post-24 hour time point. Extra-hepatic, extra-splenic tumors, including histiocytic sarcoma, anaplastic sarcoma, mammary carcinoma and lung tumors, were visualized with a heterogeneous enhancement pattern in the post-24 hour scan.Conclusions
The long circulating liposomal-iodine contrast agent enabled prolonged visualization of small and large tumors in companion dogs with naturally occurring cancer. The study warrants future work to assess the sensitivity and specificity of the Liposomal-I agent in various types of naturally occurring canine tumors. 相似文献19.
Objectives
Typical streak artifacts known as metal artifacts occur in the presence of strongly attenuating materials in computed tomography (CT). Recently, vendors have started offering metal artifact reduction (MAR) techniques. In addition, a MAR technique called the metal deletion technique (MDT) is freely available and able to reduce metal artifacts using reconstructed images. Although a comparison of the MDT to other MAR techniques exists, a comparison of commercially available MAR techniques is lacking. The aim of this study was therefore to quantify the difference in effectiveness of the currently available MAR techniques of different scanners and the MDT technique.Materials and Methods
Three vendors were asked to use their preferential CT scanner for applying their MAR techniques. The scans were performed on a Philips Brilliance ICT 256 (S1), a GE Discovery CT 750 HD (S2) and a Siemens Somatom Definition AS Open (S3). The scans were made using an anthropomorphic head and neck phantom (Kyoto Kagaku, Japan). Three amalgam dental implants were constructed and inserted between the phantom’s teeth. The average absolute error (AAE) was calculated for all reconstructions in the proximity of the amalgam implants.Results
The commercial techniques reduced the AAE by 22.0±1.6%, 16.2±2.6% and 3.3±0.7% for S1 to S3 respectively. After applying the MDT to uncorrected scans of each scanner the AAE was reduced by 26.1±2.3%, 27.9±1.0% and 28.8±0.5% respectively. The difference in efficiency between the commercial techniques and the MDT was statistically significant for S2 (p=0.004) and S3 (p<0.001), but not for S1 (p=0.63).Conclusions
The effectiveness of MAR differs between vendors. S1 performed slightly better than S2 and both performed better than S3. Furthermore, for our phantom and outcome measure the MDT was more effective than the commercial MAR technique on all scanners. 相似文献20.
Holger Hetterich Ahmad Jaber Moritz Gehring Adrian Curta Fabian Bamberg Nenad Filipovic Johannes Rieber 《PloS one》2015,10(1)