首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A test procedure was developed for the detection and quantification of 1- and 2-bromopropane in human urine. 1-Bromopropane (1-BP) is a commonly used industrial solvent, and 2-bromopropane (2-BP) is often found as an impurity component in industrial grade 1-BP. Both compounds are a health concern for exposed workers due to their chronic toxicity. Bromopropanes have been associated with neurological disorders in both animals and humans. Sample preparation consisted of diluting urine with water and fortification with 1-bromobutane (1-BB), which was used as an internal standard; then each sample was sealed in a headspace vial. A static-headspace sampler (Teledyne-Tekmar Model 7000) was used to heat each sample at 75 degrees C for a 35-min equilibrium time. Quantification was by means of a gas chromatograph (GC) equipped with an electron capture detector (ECD) and a dimethylpolysiloxane (DB-1) capillary column. A recovery study using fortified urine samples at multiple concentrations (0.5-8 microg/ml) demonstrated full recovery; 104-121% recovery was obtained. Precision ranged from 5 to 17% for the 15-20 spiked samples used at each concentration, which were analyzed over multiple experimental trial days. The limit of detection (LOD) for this test procedure was approximately 2 ng/ml 1-BP and 7 ng/ml 2-BP in urine. A recovery study of 1- and 2-BP from fortified urine stored in vials appropriate for field collection was also completed. These results and other factors of the development and validation of this test procedure will be discussed.  相似文献   

2.
An analytical procedure was developed for the detection and quantification of N-acetyl-S-(n-propyl)-l-cysteine (n-propylmercapturic acid, AcPrCys), a metabolite and biomarker for exposure to 1-bromopropane (1-BP). 1-BP is used as an industrial solvent and exposure is a health concern for industrial workers due to its toxicity. It has been associated with neurological disorders in both animals and humans. Urine sample preparation for the determination of AcPrCys consisted of solid phase extraction (SPE). Urine samples on preconditioned SPE (C18) columns were washed with 40% methanol/60% water solution prior to elution with acetone. Quantification was by means of a liquid chromatograph (LC) equipped with a mass spectrometer (MS) using an Aqua 3 μm C18 300A column and [d7]-AcPrCys was used as internal standard. Electrospray ionization (ESI) was used with the MS operated in the negative ion mode and selected ion monitoring (SIM) at m/z 204 for AcPrCys and m/z 211 for [d7]-AcPrCys. Demonstrated recovery of urine samples fortified at multiple levels (0.625–10 μg/ml) varied between 96 and 103% of theory with relative standard deviations (RSD) of 6.4% or less. The limit of detection (LOD) for the procedure was approximately 0.01 μg/ml AcPrCys in urine. These data will be discussed as well as other factors of the development of this test procedure.  相似文献   

3.
In this study, a solid-phase microextraction (SPME) method based on poly(acrylate)-coated fibres has been developed for detection and quantification of chlorinated bisphenol A in human plasma due to the need for an assessment of human exposure to them. After desorption of the analytes for 7 min at 300 degrees C, they were directly derivatized in the GC injector port by injection of 2 microL of diluted bis(trimethylsilyl)trifluoroacetamide (BSTFA). The formation of trimethylsilylate derivatives improves the selectivity, sensitivity and performance of the chromatographic properties obtained when the analytes are directly separated. Quantification was carried out using single-ion monitoring (SIM). The respective chloroderivative molecular ions appear at 406, 440, 474 and 508 m/z; whereas the base peaks corresponding to a loss of a methyl group in all cases appear at 391, 425, 459 and 493 m/z for mono-, di-, tri- and tetrabisphenol A, respectively. Deuterated bisphenol A (BPA-d16) was used as an internal standard. The method was applied to the determination of Cl-BPA, Cl2-BPA, Cl3-BPA and Cl4-BPA at very low concentration levels in plasma. Recovery efficiencies were close to 100% in all cases.  相似文献   

4.
An accurate and precise procedure was developed for the detection and quantification of (2-methoxyethoxy)acetic acid (MEAA), a metabolite and biomarker for human exposure to 2-(2-methoxyethoxy)ethanol. The compound 2-(2-methoxyethoxy)ethanol has a wide array of industrial applications including its use as an additive in military jet fuel. Exposure to 2-(2-methoxyethoxy)ethanol is a health concern owing to its toxicity which includes developmental and teratogenic properties. Sample preparation consisted of liquid-liquid extraction (LLE) and esterification of MEAA to produce the ethyl ester. Measurement was by a gas chromatograph (GC) equipped with a mass selective detector (MSD) using a HP-1 capillary column. Recovery studies of spiked blank urine demonstrated good accuracy and precision; recovery varied between 95 and 103% with relative standard deviations of 8.6% and less. The limit of detection (LOD) for this procedure was found to range from 0.02 to 0.08 microg/ml equivalent levels of MEAA in urine. These data and other aspects of the validation of this procedure will be discussed.  相似文献   

5.
The purposes of the present study are (1) to develop a sensitive analytical method to measure 1-bromopropane (1-BP) in urine, (2) to examine if 1-BP or bromide ion (Br) in urine is a useful biomarker of exposure to 1-BP, and (3) to identify the lowest 1-BP exposure concentration the method thus established can biomonitor. A factory survey was carried out on Friday, and 33 workers (all men) in cleaning and painting workshops participated; each worker was equipped with a diffusive sampler (carbon cloth KF-1500 as an adsorbent) to monitor 1-BP vapour for an 8-h shift, and offered a urine sample at the end of the shift for measurement of 1-BP and Br in urine. In addition, 10 non-exposed men offered urine samples as controls. The performance of the carbon cloth diffusive sampler was examined to confirm that the sampler is suitable for monitoring time-weighted average 1-BP vapour exposure. A head-space GC technique was employed for analysis of 1-BP in urine, whereas Br in urine was analysed by ECD-GC after derivatization to methyl bromide. The workers were exposed to vapours of seven other solvents (i.e. toluene, xylenes, ethylbenzene, acetone, etc.) in addition to 1-BP vapour; the 1-BP vapour concentration was 1.4 ppm as GM and 28 ppm as the maximum. Multiple regression analysis however showed that 1-BP was the only variable that influenced urinary 1-BP significantly. There was a close correlation between 1-BP in urine and 1-BP in air; the correlation coefficient (r) was >0.9 with a narrow variation range, and the regression line passed very close to the origin so that 2 ppm 1-BP exposure can be readily biomonitored. The correlation of Br in urine with 1-BP in air was also significant, but the r (about 0.7) was smaller than that for 1-BP, and the background Br level was also substantial (about 8 mg l-1). Thus, it was concluded that 1-BP in end-of-shift urine is a reliable biomarker of occupational exposure to 1-BP vapour, and that Br in urine is less reliable.  相似文献   

6.
1-bromopropane (1-BP; n-propyl bromide) (CAS No. 106-94-5) is an alternative to ozone-depleting chlorofluorocarbons that has a variety of potential applications as a degreasing agent for metals and electronics, and as a solvent vehicle for spray adhesives. Its isomer, 2-brompropane (2-BP; isopropyl bromide) (CAS No. 75-26-3) impairs antioxidant cellular defenses, enhances lipid peroxidation, and causes DNA damage in vitro. The present study had two aims. The first was to assess DNA damage in human leukocytes exposed in vitro to 1- or 2-BP. DNA damage was also assessed in peripheral leukocytes from workers with occupational exposure to 1-BP. In the latter assessment, start-of- and end-of-work week blood and urine samples were collected from 41 and 22 workers at two facilities where 1-BP was used as a solvent for spray adhesives in foam cushion fabrication. Exposure to 1-BP was assessed from personal-breathing zone samples collected for 1-3 days up to 8h per day for calculation of 8h time weighted average (TWA) 1-BP concentrations. Bromide (Br) was measured in blood and urine as a biomarker of exposure. Overall, 1-BP TWA concentrations ranged from 0.2 to 271 parts per million (ppm) at facility A, and from 4 to 27 ppm at facility B. The highest exposures were to workers classified as sprayers. 1-BP TWA concentrations were statistically significantly correlated with blood and urine Br concentrations. The comet assay was used to estimate DNA damage. In vitro, 1- or 2-BP induced a statistically significant increase in DNA damage at 1mM. In 1-BP exposed workers, start-of- and end-of-workweek comet endpoints were stratified based on job classification. There were no significant differences in DNA damage in leukocytes between workers classified as sprayers (high 1-BP exposure) and those classified as non-sprayers (low 1-BP exposure). At the facility with the high exposures, comparison of end-of-week values with start-of-week values using paired analysis revealed non-sprayers had significantly increased comet tail moments, and sprayers had significantly increased comet tail moment dispersion coefficients. A multivariate analysis included combining the data sets from both facilities, log transformation of 1-BP exposure indices, and the use of multiple linear regression models for each combination of DNA damage and exposure indices including exposure quartiles. The covariates were gender, age, smoking status, facility, and glutathione S-transferase M1 and T1 (GSTM1, GSTT1) polymorphisms. In the regression models, start-of-week comet tail moment in leukocytes was significantly associated with serum Br quartiles. End-of-week comet tail moment was significantly associated with 1-BP TWA quartiles, and serum Br quartiles. Gender, facility, and GSTM1 had a significant effect in one or more models. Additional associations were not identified from assessment of dispersion coefficients. In vitro and in vivo results provide limited evidence that 1-BP exposure may pose a small risk for increasing DNA damage.  相似文献   

7.
This study was conducted to estimate the health risk to workers exposed to 1-bromopropane (1-BP) used as a cleaning solvent in their workplaces. Fifty samples from 10 workplaces that use 1-BP as a cleaning solvent were obtained to assess 1-BP concentrations. An exposure assessment revealed central tendency exposure (CTE) and reasonable maximum exposure (RME) levels of 82.1 and 214.8 mg/m3, respectively. For risk characterization, the 1-BP exposure concentrations for reproductive and developmental toxicities were calculated as 2.8 and 8.5 mg/m3, respectively, and compared with the reference concentrations in the workplace. The CTE and RME hazard quotients (HQ) were, respectively, 29.4 and 77.0 for reproductive toxicity and 9.6 and 25.2 for developmental toxicity. The results of our 1-BP risk assessment indicated that the CTE-HQs for both categories were higher than the acceptable risk value of 1, indicating that 1-BP may be considered as harmful to workers.  相似文献   

8.
We have developed and validated a new, reliable and very sensitive method for the determination of the urinary metabolites of the most common pyrethroids in one analytical run. After acidic hydrolysis for the cleavage of conjugates, the analytes cis-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cis-Cl(2)CA), trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (trans-Cl(2)CA), cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (Br(2)CA), 4-fluoro-3-phenoxybenzoic acid (F-PBA) and 3-phenoxybenzoic acid (3-PBA) were extracted from the matrix with a liquid-liquid extraction procedure using n-hexane under acidic conditions. For further clean-up, NaOH was added to the organic phase and the carboxylic acids were re-extracted into the aqueous phase. After acidification and extraction into n-hexane again, the metabolites were then derivatised to volatile esters using N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamid (MTBSTFA). Separation and detection were carried out using capillary gas chromatography with mass-selective detection (GC-MS). 2-Phenoxybenzoic acid (2-PBA) served as internal standard for the quantification of the pyrethroid metabolites. The limit of detection for all analytes was 0.05 microg/l urine. The RSD of the within-series imprecision was between 2.0 and 5.4% at a spiked concentration of 0.4 microg/l and the relative recovery was between 79.3 and 93.4%, depending on the analyte. This method was used for the analysis of urine samples of 46 persons from the general population without known exposure to pyrethroids. The metabolites cis-Cl(2)CA, trans-Cl(2)CA and 3-PBA could be found in 52, 72 and 70% of all samples with median values of 0.06, 0.11 and 0.16 microg/l, respectively. Br(2)CA and F-PBA could also be detected in 13 and 4% of the urine samples.  相似文献   

9.
A binding protein for plasminogen activator inhibitor 1 (PAI-1-BP) was isolated from human plasma by a four-step procedure. 1) The 7 S globulin fraction of plasma was isolated by gel filtration on Sephacryl S-300. 2) Human endothelial cell-type plasminogen activator inhibitor (PAI-1), pretreated with 12 M urea, was added to this fraction (22 micrograms of PAI-1/ml of plasma), and a PAI-1 antigen peak with apparent mass 450 kDa (representing 65% of PAI-1 antigen and 85% of PAI activity) was isolated by gel filtration of this mixture. 3) The PAI-1.PAI-1-BP complex was further purified by immunoadsorption on an immobilized murine monoclonal antibody directed against PAI-1 (MA-7D4) and by elution with 4 M KSCN. 4) The complex was then dissociated by addition of excess human tissue-type plasminogen activator (t-PA), and t-PA and PAI-1 antigen (t-PA.PAI-1 complexes and free t-PA and PAI-1) were removed by immunoadsorption on monoclonal antibodies directed against t-PA (MA-62E8) and against PAI-1 (MA-7D4 and MA-12A4). Sodium dodecyl sulfate-gel electrophoresis of the purified material under nonreducing conditions revealed two bands with apparent mass approximately equal to 150 kDa and two bands with mass 74 and 68 kDa. Reduced sodium dodecyl sulfate-gel electrophoresis displayed two main bands with apparent masses of 73 and 64 kDa. The PAI-1-BP reacts with urea-treated, but not with inactive PAI-1. t-PA dissociates the complex between PAI-1 and PAI-1-BP. PAI-1 in complex with PAI-1-BP is 2-3-fold more stable at 37 degrees C than purified PAI-1, suggesting that PAI-1-BP may stabilize PAI-1 in blood. The concentration of PAI-1-BP in plasma determined by titration with PAI-1 is approximately 130 mg/liter. The isolated PAI-1-BP was shown to be identical to S protein (vitronectin) both by cross-reactivity with monospecific rabbit antisera and by NH2-terminal amino acid sequence analysis. The gel filtration behavior, mobility on sodium dodecyl sulfate-gel electrophoresis, and concentration in plasma suggest that PAI-1-BP is a multimer (presumably a dimer) of S protein accounting for approximately 35% of the S protein in plasma.  相似文献   

10.
BackgroundThe determination of various selenium species in urine enables a specific biomonitoring of the exposure to different selenium compounds.MethodsFor this task a coupling of three chromatographic techniques with ICP-MS was developed for the separate quantification of eleven species in urine. The first procedure was based on reverse phase chromatography and was designed for the separate determination of methyl-2-acetamido-2-deoxy-1-seleno-b-d-galactopyranoside (SeSug1), methyl-2-acetamido-2-deoxy-1-seleno-b-d-glucopyranoside (SeSug2), selenomethionine (SeMet), methylselenocysteine (MeSeC), seleno-D,L-ethionine (SeEt), methylselenic acid (MeSeA) and methylselenoglutathione (MeSeG); the second procedure was based on anion exchange chromatography and measured selenate (Se (VI)) and selenite (Se (IV)); the third procedure was based on cationic exchange chromatography and determined methyl-2-amino-2-deoxy-1-seleno-b-d-galactopyranoside (SeSug3) and the trimethylselenium ion (TMSe). A fourth method for the more sensitive determination of TMSe was upgraded by an on-line after-column reaction process.ResultsThe validation of the methods yielded sensitive detection limits of the species between 0.03 and 0.10 μg Se/L. For TMSe a detection limit of 0.02 μg Se/L resulted by the fourth method. An intra-day precision of 2.7–10.6% and a relative recovery between 87 % and 108 % confirm the robustness of the methods.ConclusionThe developed procedures enable a separate and sensitive determination of eleven selenium species in urine and thus permit the exploring of metabolic factors in the general population and particularly exposed individuals.  相似文献   

11.
3-Bromopyruvic acid (3-BP) is a promising anticancer compound because it is a strong inhibitor of glycolytic enzymes, especially glyceraldehyde 3-phosphate dehydrogenase. The Warburg effect means that malignant cells are much more dependent on glycolysis than normal cells. Potential complications of anticancer therapy with 3-BP are side effects due to its interaction with normal cells, especially erythrocytes. Transport into cells is critical for 3-BP to have intracellular effects. The aim of our study was the kinetic characterization of 3-BP transport into human erythrocytes. 3-BP uptake by erythrocytes was linear within the first 3 min and pH-dependent. The transport rate decreased with increasing pH in the range of 6.0–8.0. The Km and Vm values for 3-BP transport were 0.89 mM and 0.94 mmol/(l cells x min), respectively. The transport was inhibited competitively by pyruvate and significantly inhibited by DIDS, SITS, and 1-cyano-4-hydroxycinnamic acid. Flavonoids also inhibited 3-BP transport: the most potent inhibition was found for luteolin and quercetin.  相似文献   

12.
A rapid and sensitive high performance liquid chromatography (HPLC) method with fluorescence detection has been developed for the determination of sumatriptan in human plasma. The procedure involved a liquid-liquid extraction of sumatriptan and terazosin (internal standard) from human plasma with ethyl acetate. Chromatography was performed by isocratic reverse phase separation on a C18 column. Fluorescence detection was achieved with an excitation wavelength of 225 nm and an emission wavelength of 350 nm. The standard curve was linear over a working range of 1-100 ng/ml and gave an average correlation coefficient of 0.9997 during validation. The limit of quantitation (LOQ) of this method was 1 ng/ml. The absolute recovery was 92.6% for sumatriptan and 95.6% for the internal standard. The inter-day and intra-day precision and accuracy were between 0.8-3.3 and 1.1-6.3%, respectively. This method is simple, sensitive and suitable for pharmacokinetics or bioequivalence studies.  相似文献   

13.
We described the development and full validation of rapid and accurate liquid chromatography method, coupled with tandem mass spectrometry detection, for quantification of meprobamate in human plasma with [(13)C-(2)H(3)]-meprobamate as internal standard. Plasma pretreatment involved a one-step protein precipitation with acetonitrile. Separation was performed by reversed-phase chromatography on a Luna MercuryMS C18 (20 mm×4 mm×3 μm) column using a gradient elution mode. The mobile phase was a mix of distilled water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid. The selected reaction monitoring transitions, in electrospray positive ionization, used for quantification were 219.2→158.2 m/z and 223.1→161.1m/z for meprobamate and internal standard, respectively. Qualification transitions were 219.2→97.0 and 223.1→101.1 m/z for meprobamate and internal standard, respectively. The method was linear over the concentration range of 1-300 mg/L. The intra- and inter-day precision values were below 6.4% and accuracy was within 95.3% and 103.6% for all QC levels (5, 75 and 200 mg/L). The lower limit of quantification was 1 mg/L. Total analysis time was reduced to 6 min including sample preparation. The present method is successfully applied to 24/7 clinical toxicology and demonstrated its usefulness to detect meprobamate poisoning.  相似文献   

14.
15.
A packed-column supercritical fluid chromatography/atmospheric pressure chemical-ionisation mass spectrometry (pSFC-APCI/MS) method has been developed for the determination of atropine from Atropa belladonna L extracts. The technique does not require any kind of derivatisation prior to the analysis. The optimum conditions were studied by using the pure substance in methanol (MeOH). All samples were simply dissolved in MeOH and injected into the mobile phase. Detection was achieved by using mass spectrometry (MS) with atmospheric pressure chemical ionisation (APCI). Terbutaline was used as an internal standard for the determination of the analytical reproducibility. The supercritical carbon dioxide (scCO(2)) mobile phase was modified by 15% MeOH containing 0.5% trifluoroacetic acid (TFAA) and 0.5% diethylamine (DEA) additives. Concentrations of atropine were determined with a relative standard deviation of less than 1% by the pSFC-APCI/MS procedure for a sample containing atropine and terbutaline. The correlation coefficient was 0.997 and detection limit 700 pg. The absolute retention time was 9.87 min with a standard deviation of 5.2x10(-3) min and a relative standard deviation of 0.61% with respect to terbutaline.  相似文献   

16.
Simultaneous measurement of isoniazid and its main acetylated metabolite acetylisoniazid in human plasma is realized by high-performance liquid chromatography. The technique used is evaluated by a factorial design of validation that proved to be convenient for routine drug monitoring. Plasma samples are deproteinized by trichloroacetic acid and then the analytes are separated on a microBondapak C18 column (Waters). Nicotinamide is used as an internal standard. The mobile phase is 0.05 M ammonium acetate buffer (pH 6)-acetonitrile (99:1, v/v). The detection is by ultraviolet absorbance at 275 nm. The validation, using the factorial design allows one to: (a) test the systematic factors of bias (linearity and matrix effect); (b) estimate the relative standard deviations (RSDs) related to extraction, measure and sessions assay. The linearity is confirmed to be within a range of 0.5 to 8 microg/ml of isoniazid and 1 to 16 microg/ml of acetylisoniazid. This method shows a good repeatability for both extraction and measurement (RSD INH=3.54% and 3.32%; RSD Ac.INH=0.00% and 5.97%), as well as a good intermediate precision (RSD INH=7.96%; RSD Ac.INH=15.86%). The method is also selective in cases of polytherapy as many drugs are associated (rifampicin, ethambutol, pyrazinamide, streptomycin). The matrix effect (plasma vs. water) is negligible for INH (3%), but statistically significant for Ac.INH (11%). The application of this validation design gave us the possibility to set up an easy and suitable method for INH therapeutic monitoring.  相似文献   

17.
The NucliSens Extractor in combination with the 2.0 version of the Roche Cobas HCV Amplicor test has been validated by five European blood screening laboratories in a multi-centre study. For testing the performance characteristics of this HCV-NAT method, the European Pharmacopoeia validation guidelines were followed. The CLB VQC reference reagents were used for testing robustness and sensitivity. After a technical improvement in the extraction stations, the NucliSens Extractor appeared to be contamination-free as was proved by testing negative controls alternating with samples containing a high HCV-RNA concentration. The Pelicheck HCV-RNA genotype 1 dilution panel was tested 74 times in the five laboratories and an overall 95% detection limit of 80 genome equivalents (geq)/ml was found. In one laboratory the Pelicheck panel was tested in 25 runs and here a 95% detection limit of 32 geq/ml was achieved. In this laboratory the Pelispy HCV-RNA run control samples of 140 geq/ml were consistently picked up in all extractor stations. In addition the laboratories have tested a WHO HCV-RNA genotype 1 standard dilution series 39 times and a Pelicheck HCV-RNA genotype 3 reference panel in 32 test runs. The limiting dilution analysis enabled us to compare the detection efficiency of the NucliSens-Amplicor method for the genoype 1 and genotype 3 isolates and to calibrate the reference reagents against each other. The combined Nuclisens-Amplicor method was found to detect the genotype 3 isolate in the Pelicheck HCV-RNA panels with 2-3 fold lower efficiency than the genotype 1 standard (assuming that the historical calibration of the genotype 3 against the genotype 1 standard is correct). In this study of a single method 1 IU of the WHO HCV-RNA standard was found to be equivalent to 5.1 geq of the VQC HCV-RNA standard (95% confidence intervals 3.1-9.1 geq). To avoid confusion with the use of the CLB VQC reagents we accept the NIBSC collaborative study in which calibration by a variety of methods showed that the Pelispy 380 geq/ml run control is equivalent to 100 IU/ml of the WHO standard. This multi-centre validation study demonstrates that the 95% detection limit of the NucliSens HCV Amplicor method lies far below the detection limits required by the international regulatory bodies.  相似文献   

18.
Luner PE  Patel AD 《AAPS PharmSciTech》2005,6(2):E245-E252
The objective of this study was to use diffuse reflectance near infrared spectroscopy (NIRS) to determine racemic compound content in physical mixtures composed primarily of the enantiomorph and to assess the error, instrument reproducibility and limits of detection (LOD) and quantification (LOQ) of the method. Physical mixtures ranging from 0 to 25% (±)-tartaric acid in (+)-tartaric acid were prepared and spectra of the powder samples contained in glass vials were obtained using a Foss NIRSystems Model 5000 monochrometer equipped with a Rapid Content Analyzer scanning from 1100 to 2500 nm. A calibration curve was constructed by plotting (±)-tartaric acid weight percent against the 2nd derivative values of log (1/R) vs λ at a single wavelength, normalized with a denominator wavelength (1480 nm/1280 nm). Excellent linearity was observed (R2=0.9999). The standard error of calibration (SEC) was 0.07 and the standard error of prediction (SEP) for the validation set was 0.11. Instrument and method errors for samples in the 2% composition range ((±)-tartaric acid in (+)-tartaric acid) were less than 1% RSD and 3% RSD, respectively. The practical LOD and LOQ were 0.1% and 0.5%, respectively, and comparable to the calculated LOD and LOQ. These studies show that NIRS can be used as a rapid and sensitive quantitative method for determining racemate content in the presence of the enatiomerically pure crystal in the solid-state. Published: October 6, 2005  相似文献   

19.
A high-performance liquid chromatography (HPLC) method was developed that can separate and quantify dipalmitoylphosphatidylcholine and its degradation product, palmitic acid from various phospholipids contained in a porcine lung surfactant used in the treatment of respiratory distress syndrome, which was recently approved for use by the FDA. The method used a C8 reversed-phase HPLC column with a (50:45:10) acetonitrile/methanol/acetic acid mobile phase, and refractive index detection. The active component of the lung surfactant, dipalmitoylphosphatidylcholine (DPPC) and palmitic acid (PA), could be quantified following a liquid-liquid extraction procedure along with an internal standard, dimyristoylphosphatidylcholine (DMPC). The assay was validated for linearity, accuracy, precision, reproducibility and ruggedness. Column stability was measured by performing the assay over time and monitoring the system suitability parameters. The extraction procedure has a 90% recovery and the assay is linear over a range of 5 μg/ml to 300 μg/ml. The assay is used to release commercial product and monitor stability of existing lots of material.  相似文献   

20.
A high-performance liquid chromatography (HPLC) method with UV detection was developed for the simultaneous determination of arsanilic acid, roxarsone, nitarsone, and carbarsone in the feeds of swine and chicken. Feed samples were extracted with methanol/1% acetic acid (90:10, v/v) in an ultrasonic bath and the protein was precipitated with 2% Cu(2)SO(4). The samples were further purified by solid phase extraction (SPE) on SAX cartridges. Separation was performed on a Zorbax SB-Aq C18 HPLC column using an isocratic procedure with methanol and 1% acetic acid (3:97, v/v) at a flow-rate of 0.7 mL min(-1), and the UV detector was set at a wavelength of 260 nm. The recoveries of organoarsenic compounds spiked at levels of 2, 20 and 200 μg g(-1) ranged from 81.2% to 91.3%; the inter-day relative standard deviation values were less than 7.0%. The limits of quantification for four organoarsenic compounds were 1.0-2.0 μg g(-1). This simple and fast method could be applied to the determination of multi-residues of organic arsenic compounds in animal feeds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号