首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
Automation of donor management flow path is controlled by: --a 3 slip "port a punch" card, --the groupamatic unit with a result sorted out on punch paper tape, --the management computer off line connected to groupamatic. Data tracking at blood collection time is made by punching a card with the donor card used as a master card. Groupamatic performs: --a standard blood grouping with one run for registered donors and two runs for new donors, --a phenotyping with two runs, --a screening of irregular antibodies. Themanagement computer checks the correlation between the data of the two runs or the data of a single run and that of previous file. It updates the data resident in the central file and prints out: --the controls of the different blood group for the red cell panel, --The listing of error messages, --The listing of emergency call up, --The listing of collected blood units when arrived at the blood center, with quantitative and qualitative information such as: number of blood, units collected, donor addresses, etc., --Statistics, --Donor cards, --Diplomas.  相似文献   

3.
OBJECTIVE--To estimate the risk of infection with HIV (HIV 1 or HIV 2, or both) from transfusion of a screened unit of blood in a high prevalence area in west Africa. DESIGN--Retrospective cohort study for January-July 1991. SETTING--National Blood Transfusion Centre, Abidjan, Côte d''Ivoire. SUBJECTS--Repeat donors (5831 units of blood) and first time donors (5076 units) in the first five months of 1991. MAIN OUTCOME MEASURES--Prevalence and estimated incidence of HIV infection in repeat and first time donors; estimated rate of potentially infected, HIV antibody negative units; and rate of (false negative) potentially infected units assuming a laboratory test sensitivity of 99%. RESULTS--Overall HIV prevalence was 11.0% in first time donors and 2.1% in repeat donors. In the first seven months of 1991, 29 HIV antibody positive (27 HIV 1, 1 HIV 2, 1 dually reactive) donors with a seronegative unit of blood earlier in the year were identified; 26 had donated blood eight weeks or less before their estimated dates of seroconversion and may have been infectious (minimum rate 26/5831 (4.5/1000 potentially infected units)). Estimated incidence of infection in repeat donors was 1.2-2.5%. Laboratory test insensitivity would result in an estimated 1.1/1000 false negative units from first time donors and 0.2/1000 units from regular donors. The overall rate of potentially infected units (all donors, seroconversions, and errors) was estimated at 5.4-10.6/1000. CONCLUSIONS--The risk of HIV infection from a single unit of blood remains substantial (5.4-10.6/1000 units). To prevent infection from blood transfusion in areas of high incidence and prevalence of HIV all but absolutely essential transfusions should be avoided, and donors with low incidence of HIV infection should be selected.  相似文献   

4.
Burkina Faso is a continental West African country of approximately 16 M people whose transfusion needs were covered by 66,210 blood units collected mostly in 4 regional transfusion centers part of a national network but also from hospital-based smaller blood centers. The first group of blood centers relies almost exclusively on volunteer, non-remunerated, blood donors and only approximately 32.7% of them are repeating donation. In contrast, hospital-based blood centers rely nearly exclusively on family/replacement donors. The general strategy of the national blood transfusion network was to base the system exclusively on volunteer donors, which was nearly accomplished overall and completely at Bobo-Dioulasso, the largest center. However, despite considerable increase in blood collection, the overall blood supply remains low (4.7 units/1000 inhabitants) and worsens during the secondary school recesses since young student blood constitutes the most part of volunteer donors. To overcome such shortages, mobile blood collection sessions are organized in alternate sites such as military barracks or places of worship but with limited success. Another critical issue is that despite considerable efforts and help from community advocates, only 32.7% of volunteers repeat donation limiting the considerably safety advantage of a pool of regular donors.  相似文献   

5.
We studied a group of 64 patients undergoing cardiac surgery for the occurrence of post-transfusion hepatitis during a follow-up period of 5 months. They received blood units (packed red cells in saline-adenine-glucose medium and/or fresh frozen plasma exclusively) from 447 volunteer donors. Post-transfusion hepatitis was identified in 5 patients: 1 patient had cytomegalovirus hepatitis and the remaining 4 cases were defined, by exclusion, as non-A, non-B hepatitis (with prevalence and incidence rates of 80% and 6.25% respectively). We found no statistically significant differences between the numbers of transfused blood product units in patients who developed non-A, non-B hepatitis as compared to those who did not. Our analysis of the predictive effectiveness of alanine aminotransferase and anti-HBc antibodies screening in blood donors to prevent non-A, non-B post-transfusion hepatitis led to the following conclusions: we failed to confirm the association between anti-HBc in blood donors and enhanced risk of non-A, non-B hepatitis in recipients since no case developed among patients receiving blood products from anti-HBc positive donors. So, 20 donors (4.5%) would have been discarded without any reduction of the incidence of non-A, non-B hepatitis. we could not confirm nor exclude the possibility that screening donor blood for elevated alanine aminotransferase levels would have reduced the number of non-A, non-B hepatitis in recipients.  相似文献   

6.
The purpose of this study was to assess plasma selenium levels in an Australian blood donor population and measure extra-cellular selenium levels in fresh manufactured blood components. Selenium levels were measured using graphite furnace atomic absorption spectrometry with Zeeman background correction. The mean plasma selenium level in healthy plasmapharesis donors was 85.6 ± 0.5 μg/L and a regional difference was observed between donors in South East Queensland and Far North Queensland. Although participants had selenium levels within the normal range (55.3–110.5 μg/L), 88.5% had levels below 100 μg/L, a level that has been associated with sub-optimal activity of the antioxidant enzyme glutathione peroxidase (GPx). Extra-cellular selenium levels in clinical fresh frozen plasma (cFFP) and apheresis-derived platelets (APH Plt) were within the normal range. Packed red blood cells (PRBC) and pooled buffy coat-derived platelets (BC Plt) had levels at the lower limit of detection, which may have clinical implications to the massively transfused patient.  相似文献   

7.
IntroductionMost African countries are challenged in recruiting and retaining voluntary blood donors by cost and other complexities and in establishing and implementing national blood policies. The availability of replacement donors who are a cheaper source of blood has not enhanced repeat voluntary donor initiatives.MethodsAn overview of activities for recruiting and retaining voluntary blood donors was carried out. Donor records from mobile sessions were reviewed from 2002 to 2008.Results and discussionA total of 71,701 blood donations; 45,515 (63.5%) being voluntary donations with 11,680 (25%) repeat donations were collected during the study period. Donations from schools and colleges contributed a steady 60% of total voluntary whilst radio station blood drives increased contribution from 10 to 27%. Though Muslim population is less than 20%, blood collection was above the 30-donation cost-effectiveness threshold with a repeat donation trend reaching 60%. In contrast Christian worshippers provided <25 unit/session and 30% repeat donations. Repeat donation trends amongst school donors and radio blood drives were 20% and 70% respectively.ConclusionRepeat donations rates have been variable amongst different blood donor groups in Kumasi, Ghana. The impact of community leaders in propagating altruism cannot be overemphasized. Programs aiming at motivating replacement donors to be repeat donors should be developed and assessed.  相似文献   

8.
Previously, treatment of Tamm-Horsfall glycoprotein (THp) from different donors with endo-beta-galactosidase has been shown to liberate a tetra- and a Sd(a)-active pentasaccharide, concluding the presence of N-linked carbohydrate chains containing additional N - acetyllactosamine units. These type of oligosaccharides were not found in a detailed structure elucidation of the carbohydrate moiety of THp of one male donor, suggesting a donor-specific feature for these type of structures. Therefore, THp was isolated from four healthy male donors and each subjected to endo-beta-galactosidase treatment in order to release these tetra- and Sd(a)-active pentasaccharide. Differences were observed in the total amount of released tetra- and Sda-active pentasaccharide of the used donors (42, 470, 478, 718 microg/100 mg THp), indicating that the presence of repeating N-acetyllactosamine units incorporated into the N-glycan moiety of THp is donor specific. Furthermore, a higher expression of the Sd(a) determinant on antennae which display N-acetyllactosamine elongation was observed, suggesting a better accessibility for the beta-N-acetylgalactosaminyltransferase. In order to characterize the N-glycans containing repeating N- acetyllactosamine units, carbohydrate chains were enzymatically released from THp and isolated. The tetraantennary fraction, which accounts for more than 33% of the total carbohydrate moiety of THp, was used to isolate oligosaccharides containing additional N - acetyllactosamine units. Five N-linked tetraantennary oligosaccharides containing a repeating N-acetyllactosamine unit were identified, varying from structures bearing four Sd(a) determinants to structures containing no Sd(a) determinant (see below). One compound was used in order to specify the branch location of the additional N- acetyllactosamine unit, and it appeared that only the Gal-6' and Gal-8' residues were occupied by a repeating N -acetyllactosamine unit.   相似文献   

9.
The transfer of [3H]uridine nucleotides from donor (uridine-loaded) to recipient (thymidine-prelabelled) pancreatic endocrine islet cells in monolayer culture was qualitatively and quantitatively assessed by light and electron microscope autoradiography. Recipient cells showed a labelled cytoplasm only when they were in contact with donor cells or positive recipients. Controls indicated that the labelling was not due to the incorporation of [3H]uridine, 3H nucleotides or nucleic acids lost by donor cells in the medium. Quantitation showed that cytoplasmic labelling of positive recipient cells was higher than cellular background, but lower than the cytoplasmic labelling of donor cells. These data indicate that label in recipient cells was derived from donors by direct intercellular transfer of 3H nucleotides. Differentiated insulin-producing cells (B cells) were involved in the exchange.  相似文献   

10.
R S Remis  G Delage  R W Palmer 《CMAJ》1997,157(4):375-382
OBJECTIVES: To determine the incidence (including associated donor characteristics and time trends) of HIV infection among repeat blood donors and to estimate the risk of HIV transmission from blood transfusion in Montreal and in Canada as a whole. DESIGN: Retrospective cohort analysis. SETTING: Montreal Centre Blood Transfusion Service. PARTICIPANTS: People who donated blood at least twice after Nov. 1, 1985, and at least once from Apr. 1, 1989, to Mar. 31, 1993. INTERVENTION: Blood was screened for HIV by enzyme-linked immunosorbent assay and results were confirmed by Western blot analysis. OUTCOME MEASURES: Incidence density (the incidence rate per person-time) of HIV infection among repeat blood donors by sex, age group and region of residence, and incidence density and risk among first-time donors and for Canada as whole. RESULTS: There were 200,196 eligible donors and 432,631 person-years (PY) of observation. From 1989 to 1993, there were 18 HIV seroconversions among repeat donors. The crude incidence density was 3.3 per 100,000 PY (95% confidence interval [CI] 1.8 to 5.4 per 100,000 PY); it was 4.9 per 100,000 PY among men and 0.61 per 100,000 PY among women. Age-specific incidence per 100,000 PY was 2.5 among those 12-29 years of age, 5.1 among those 30-49, 2.9 among those 40-49, and 1.4 among those 50 and older. Based on an estimated mean "window period" (from when a donor''s blood is capable of transmitting HIV until detectable antibody appears) of 25 days, the current risk of HIV infection from repeat donors in the window period is estimated at 1 in 440,000. Inclusion of blood units from first-time donors produces an overall risk of 1 in 390,000 (95% CI 1 in 250,000 to 655,000). The estimated risk per blood unit in Canada as a whole is 1 in 913000 (95% CI 1 in 507,000 to 2,050,000). CONCLUSIONS: This "sentinel" population of repeat blood donors is subject to important trends in HIV spread. Therefore, estimating the incidence density of HIV infection in repeat donors provides insight into the epidemiologic characteristics of HIV infection at minimal expense. As a result of measures to improve blood safety, including HIV testing, the incidence of HIV infection among blood donors in Canada is low and the risk of HIV transmission from transfusion is extremely small, although not zero.  相似文献   

11.
Abstract Inhibition of adherence of bacteria to epithelial cells contributes to a reduction of infections by these bacteria. We have shown that the Anton blood group antigen, the erythrocyte receptor for Haemophilus influenzae (van Alphen et al. 1986, FEMS Microbiol. Lett. 37, 69–71), occurs in saliva, that the occurrence is not related to the secretor state of the donor of the saliva and that saliva containing Anton antigen could not inhibit the adherence of H. influenzae to oropharynx epithelial cells.
Anton antigen was detected in saliva samples of 14 donors by immunoblotting with two different anti-Anton sera. The amount of Anton antigen correlated with the ability of H. influenzae to adhere to the epithelial cells of the donor of the saliva: 4.1 ± 0.1 Anton antigen units for donors with more than 50 H. influenzae per cell and 1.6 ± 0.5 units for donors with less adhering epithelial cells. No correlation between the amount of Anton antigen in saliva and secretor status of the donor was observed. Adherence of H. influenzae to epithelial cells was not inhibited by saliva of secretors ( N = 11) or non-secretors ( N = 3). The same saliva did not inhibit the interaction of the bacteria with Anton antigen bearing erythrocytes as measured by haemagglutination inhibition. This indicates that the amount of Anton antigen in saliva is probably too low to interfere with the interaction of H. influenzae with oropharynx epithelial cells and erythrocytes.  相似文献   

12.
The 1-(secondary amino) diazen-1-ium-1,2-diolates (NONOates) are the most commonly utilized nitric oxide (NO, nitrogen monoxide) donor because of the ability of different NONOates to spontaneously break down liberating NO at different rates, which can be utilized to control NO fluxes. However, the parameters that determine these fluxes of NO generation, half-lives and stoichiometry of NO per donor, can vary significantly with specific experimental conditions in addition to the donor chosen. Here we report straightforward methods that can be used to determine these parameters. For donors of intermediate half-life (10–80 min) a real-time oxymyoglobin (oxyMb) assay can be analyzed to simultaneously determine both the half-life and the total amount of NO liberated, from which the NO flux can be obtained for any given donor concentration. The half-lives obtained by oxyMb assay are very similar to those obtained by following NONOate decomposition kinetics spectrophotometrically, and a survey of several NONOates from different commercial sources show consistent results. These data provide validation for the methodologies employed. In addition, procedures are described for calibration of donors with shorter (<10 min) and longer (>80 min) half-lives. These procedures can be used to reproducibly and routinely calibrate NO fluxes for a variety of donors under any specific condition.  相似文献   

13.
Wofford J  Kemp J  Regan D  Creer M 《Cytotherapy》2007,9(7):660-666
BACKGROUND: For ethnic minority patients where a suitably matched BM or peripheral blood donor is frequently unavailable, cord blood offers an opportunity for hematopoietic stem cell transplantation. Focused recruitment of ethnic minorities for cord blood donation has been proposed as the preferred strategy to improve access for minority recipients to cord blood for transplantation. The aim of this study was to evaluate cord blood characteristics for Caucasian and African American donors and the success of ethnically mismatched UC blood transplantation in African American recipients. METHODS: Retrospective data analysis was performed comparing the characteristics of 556 cord blood units from African American and Caucasian donors. The outcomes of 18 African American ethnically mismatched transplant recipients were compared with a paired sample of 18 ethnically matched Caucasian recipients. RESULTS: The fraction of collected units meeting acceptability criteria from African Americans was significantly lower compared with Caucasians (P = <0.0001). Additionally, African Americans had a significantly lower post-processing total nucleated cell count (TNC) compared with Caucasians (P=0.007) but there were no other significant differences in conventionally measured product characteristics. In the transplant analysis, there was no difference in overall survival at 1 year (P=0.85) or time to neutrophil engraftment (P=0.92) between the two patient populations. DISCUSSION: At comparable levels of TNC dose and HLA matching, the use of ethnically mismatched UC blood units as a source for allogeneic unrelated transplant can result in successful transplant outcomes for African American patients.  相似文献   

14.
This report was presented at the June 1983 meeting of the Blood Transfusion National Consultative Commission at the French Ministry of Health. Clinical and epidemiological data on AIDS as well as problems raised by the lack of specific tests for screening of blood donors were briefly summarized. Out of 49 AIDS patients recorded in France up to April 1983, only one had a history of previous blood transfusion given in Haiti, 4 years before the clinical onset of the disease. Blood donors, all Haitians, had no sign and symptom of AIDS. Retrospective review of 2 300 hemophiliacs followed up in France until April 1983 disclosed no AIDS. However, in 6 patients, the following features, more or less associated, were found to be present: thrombocytopenia, neutropenia, micropolyadenopathy, splenomegaly, hypergammaglobulinemia and low OKT4/OKT8 ratio. No clear correlation could be found between these abnormalities and the origin, commercial or national, of the coagulation factor concentrates used for the treatment. Three main recommendations were proposed: -- information of blood donors and experimental evaluation of some non specific screening tests, in the at risk donor population. -- more cautious use of coagulation factor concentrates -- reduction of importations aiming at complete national self sufficiency concerning factor VIII concentrates.  相似文献   

15.
Background aimsUmbilical cord blood (UCB) is a source of hematopoietic stem cells that initially was used exclusively for the hematopoietic reconstitution of pediatric patients. It is now suggested for use for adults as well, a fact that increases the pressure to obtain units with high cellularity. Therefore, the optimization of UCB processing is a priority.MethodsThe present study focused on parameters influencing total nucleated cell (TNC), mononucleated cell (MNC) and CD34 + cell (CD34C) recovery after routine volume reduction of 1553 UCB units using hydroxyethyl starch-induced sedimentation with an automated device, under routine laboratory conditions.ResultsWe show that the unit volume rather than the TNC count significantly affects TNC, MNC and CD34C processing efficiency (PEf), and this in a non-linear fashion: when units were sampled according to the collection volume, including pre-loaded anticoagulant (gross volume), PEf increased up to a unit volume of 110–150 mL and decreased thereafter. Thus units with initial gross volumes < 90 mL and > 170 mL similarly exhibited a poor PEf.ConclusionsThese data identify unit gross volume as a major parameter influencing PEf and suggest that fractionation of large units should be contemplated only when the resulting volume of split units is > 90 mL.  相似文献   

16.
Background aimsThe rising use of allogeneic transplantation in older recipients necessitates considering older related donors. The effect of related donor age for peripheral blood stem cell allografts (PBSC) on graft maintenance and outcomes, independent of CD34+cell dose, has not been well-characterized.MethodsHLA-related donors (98% siblings) underwent a uniform filgrastim-based mobilization regimen aiming to collect and infuse 5 × 106 CD34+ cells/recipient kg. Donor and recipient age were modeled in multiple ways to account for the correlation, and outcomes reported by decade of donor age.ResultsThe median donor and recipient ages were 52 years and 54 years, respectively. The mean CD34+ cell dose infused was 5.6 × 106 CD34+/kg and 75% of patients received a narrow range between 4.4 and 6.6 × 106 CD34+ cells/kg. Neither better PBSC mobilization nor higher CD34+ content of allografts was significantly associated with engraftment or transplant outcomes. After adjusting for recipient age and other prognostic factors, older donor age by decade conferred a lower risk of non-relapse mortality (NRM) [hazard ratio (HR) = 0.64, 95% confidence interval (CI) 0.45–0.91, P = 0.013] and borderline improvement in overall survival (OS) (HR = 0.76, 95% CI 0.58–0.99, P = 0.045) without altering progression-free survival (PFS) (HR = 0.85, 95% CI 0.66–1.07, P = 0.18).ConclusionsOlder donor age does not worsen outcome after matched related donor PBSC transplantation in patients receiving a narrow range CD34+ cells. The relatively small sample size mandates that the finding of similar to improved outcomes for older related donor age must be confirmed in larger studies.  相似文献   

17.
The profit to be gained by testing Danish blood donors for hepatitis B surface antigen (HBsAg) with a third generation technique instead of the currently used immunoelectrophoresis was investigated by additional screening of 48 750 blood units by radioimmunoassay three weeks after donation. Twenty nine units were positive for HBsAg on radioimmunoassay (0.059%). Only six of these were found by immunoelectrophoresis (0.012%). Most of the 23 donors positive on radioimmunoassay and negative on immunoelectrophoresis were healthy carriers of HBsAg (20) or had asymptomatic chronic liver disease (two). One donor had acute hepatitis B. Fifteen of the 23 blood units were transfused. The 15 recipients were monitored biochemically and serologically for up to nine months. One recipient developed fulminant hepatitis B, three developed acute hepatitis B, and one became a healthy carrier of HBsAg. All these patients had received blood from healthy carriers of HBsAg. Two recipients were immunised against HBsAg, and in one patient no seroconversion was observed. The remaining recipients died soon after transfusion or were protected by antibodies to HBsAg that had been present before the transfusion. Testing of Danish blood donors using a third generation technique identified a substantial number of donors positive for HBsAg overlooked by immunoelectrophoresis. Most of these donors were healthy carriers of HBsAg. Blood taken from such carriers is highly infectious when transfused, probably because of the large amount of material transmitted.  相似文献   

18.
Autoradiographic techniques were used to measure rate of replication and length of the replication unit in cultured cells of Scaphiopus couchi, Bufo cognatus, Rana clamitans, and Triturus viridescens, having nuclear DNA amounts in the ratio 1:4:7:39 respectively. The autoradiographic experiments were designed to show whether the larger amounts of nuclear DNA are correlated with more rapid rates of synthesis and/or with longer replication units. -- The DNA replication rate was 2.5 mu/minute (corrected for two growing points) with 10 minutes 3H-thymidine label at 22 degrees C, but decreased with longer labelling durations. The length of the replication unit (estimated by the distance from the center of one autoradiograph to the center of the next in sequence) was most commonly in the 10-25 mu range with a 30 minute label, in all four species. The average center-to-center distance was 8 mu at 10 minutes and increased with label duration, to over 45 mu with 24 hours label. Replication was predominantly but not exclusively bidirectional. Neither rate of replication nor length of the replication unit was proportional to the amount of DNA in these species.  相似文献   

19.
Inhibition of adherence of bacteria to epithelial cells contributes to a reduction of infections by these bacteria. We have shown that the Anton blood group antigen, the erythrocyte receptor for Haemophilus influenzae (van Alphen et al. 1986, FEMS Microbiol. Lett. 37, 69-71), occurs in saliva, that the occurrence is not related to the secretor state of the donor of the saliva and that saliva containing Anton antigen could not inhibit the adherence of H. influenzae to oropharynx epithelial cells. Anton antigen was detected in saliva samples of 14 donors by immunoblotting with two different anti-Anton sera. The amount of Anton antigen correlated with the ability of H. influenzae to adhere to the epithelial cells of the donor of the saliva: 4.1 +/- 0.1 Anton antigen units for donors with more than 50 H. influenzae per cell and 1.6 +/- 0.5 units for donors with less adhering epithelial cells. No correlation between the amount of Anton antigen in saliva and secretor status of the donor was observed. Adherence of H. influenzae to epithelial cells was not inhibited by saliva of secretors (N = 11) or non-secretors (N = 3). The same saliva did not inhibit the interaction of the bacteria with Anton antigen bearing erythrocytes as measured by haemagglutination inhibition. This indicates that the amount of Anton antigen in saliva is probably too low to interfere with the interaction of H. influenzae with oropharynx epithelial cells and erythrocytes.  相似文献   

20.
Several factors have been proposed to influence the red blood cell storage lesion including storage duration, blood component manufacturing methodology, and donor characteristics [1,18]. The objectives of this study were to determine the impact of manufacturing method and donor characteristics on water permeability and membrane quality parameters.Red blood cell units were obtained from volunteer blood donors and grouped according to the manufacturing method and donor characteristics of sex and age. Membrane water permeability and membrane quality parameters, including deformability, hemolysis, osmotic fragility, hematologic indices, supernatant potassium, and supernatant sodium, were determined on day 5 ± 2, day 21, and day 42. Regression analysis was applied to evaluate the contribution of storage duration, manufacturing method, and donor characteristics on storage lesion.This study found that units processed using a whole blood filtration manufacturing method exhibited significantly higher membrane water permeability throughout storage compared to units manufactured using red cell filtration. Additionally, significant differences in hemolysis, supernatant potassium, and supernatant sodium were seen between manufacturing methods, however there were no significance differences between donor age and sex groups.Findings of this study suggest that the membrane-related storage lesion is initiated prior to the first day of storage with contributions by both blood manufacturing process and donor variability. The findings of this work highlight the importance of characterizing membrane water permeability during storage as it can be a predictor of the biophysical and chemical changes that affect the quality of stored red blood cells during hypothermic storage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号