首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Optimized T7 amplification system for microarray analysis.   总被引:8,自引:0,他引:8  
  相似文献   

3.
4.
5.
6.
We have used a chemiluminescent detection method to improve both the sensitivity and the speed of detection of human genes with oligonucleotide probes. A direct chemiluminescent substrate (AMPPD) was used in combination with an alkaline-phosphatase-labeled oligonucleotide probe to detect the human tissue of plasminogen activator gene by Southern blot analysis. X-ray exposures obtained after 4 h were comparable to those obtained after 7 days with a 32P-labeled oligomer. After 16 h, the signal was 12 times greater than the 32P signal. The detection of the single-copy tissue plasminogen activator gene in 0.25 micrograms of human genomic DNA (76,000 molecules) was achieved. The improved sensitivity obtained by chemiluminescent detection should increase the usefulness of oligonucleotide probes in the direct Southern analysis of human genetic disorders.  相似文献   

7.
8.
9.
We have designed and constructed an inexpensive imaging system based on charge coupled device (CCD) technology and utilized it to demonstrate the sensitivity and rapid detection possible with Lumigen® chemiluminescent reagents. We also report the development of two new chemiluminescent reagents, Lumi-Phos® Plus and Lumigen PS. Lumi-Phos Plus is an ehanced formulation for the rapid detection of alkaline phosphatase on membranes and in solution. It provides excellent images in blotting applications with exposures of under a minute. Lumigen PS represents a new generation of peroxidase detection reagents. The wide dynamic range with excellent linearity, higher signal and lower background than other chemiluminescent reagents make Lumigen PS of unsurpassed value in enzyme-linked immunoassays and nuclic acid probe assays using HRP conjugates.  相似文献   

10.
11.
12.
13.
Focused microarray analysis   总被引:9,自引:0,他引:9  
  相似文献   

14.
To date, protein and antibody microarrays have been used in reverse-phase and sandwich-based methods in order to detect known proteins such as biomarkers in samples. Our group developed "libraries" of antibodies against unknown proteins, referred to as mKIAA proteins, and we attempted to discover candidate novel biomarkers by protein expression profiling.To profile mKIAA protein expression using these antibodies, we established an antibody microarray system using chemiluminescent detection. A number of techniques for protein-antibody microarrays have been reported; however, no entirely suitable protocol for crude protein samples has been established. To address this issue, we immobilized purified antibodies on hydrophilic surface polymer slides (Maxisorp, Nunc). Although our system is based on the direct labeling of crude protein samples, we achieved sufficient sensitivity (detection limit: 50 pg mL(-1)) and low backgrounds. This sensitivity is on a level with the sandwich immunoassay-based antibody array system. Using our protocol, we developed an antibody microarray spotted with 960 anti-mKIAA antibodies (total: 3888 spots for quadruplicate assessments), and we carried out protein expression profiling of mKIAA proteins. In this study, we generated an expression profile of 960 mKIAA proteins and compared the present results with those obtained via cDNA microarray.  相似文献   

15.
We compared the sensitivity of a chemiluminescent substrate 3-(2'-spiroadamantane)-4-methoxy-4-(3"-phosphoryloxy)phenyl- 1,2-dioxetane (AMPPD) and a chromogenic substrate 5-bromo-4-chloro-3-indolyl phosphate/nitroblue tetrazolium (BCIP/NBT) for detection of an alkaline phosphatase label in a hepatitis B virus "core antigen" DNA (HBVc) probe hybridization assay. Chemiluminescent signal obtained from AMPPD hydrolysis by alkaline phosphatase was detected with Polaroid Instant Black and White Type 612 film. The chemiluminescent assay detected 1.18 x 10(6) copies of HBVc plasmid DNA in 30 min. By comparison, 9.8 x 10(7) copies of DNA could be measured using chromogenic BCIP/NBT substrate within the same incubation time. After further development, the chemiluminescent endpoint permitted detection of 4.39 x 10(4) copies of HBVc plasmid DNA in 2 h.  相似文献   

16.
17.
18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号